Loading...
HomeMy WebLinkAboutApplication-Permit.pdfI Garfield County Building & Planning Department 1088th Street, Suite #401 Glenwood Springs, Co. 81601 Office:970·945·8212 Fax: 970·384·3470 Inspection Line: 970·384·5003 Building Permit No. Parcel No: Locality: Job Address: 0050 Riverbend New Castle Owner: Contractor: Fees: ....... ------.........•...-.------.-...........--.~• ....••. -.----_. ...•.••_ ..-------Plan Check: Bldg Permit: $ $ 398.74 613.45 Total Fees: J.. __ ~.1~.12.19 Owner Septic: Other Fees: Date: I 1 2 3 GARFIELD COUNTY BUILDING PERMIT APPLICATION 108 8· Stree~ Suite 401, Glenwood Springs, Co 81601 Phone: 970-945-8212/Fax: 970-384-3470 /inspection Line: 970-384-5003 www.garfield~county.com Parcel No: (this information is available at' the assessors office 970-945-9134) 212.334402005 Job Address: (if an address has not been assigned, please provide Cr, Hwy or Street Name & City) or and legal description 0050 RIVERBEND D~-NEW CI\5,l--E i CO Lot No: Block No: 2-Subd.l Exemption: 5 RII/ERBe.ND 1sT-4 ":,~~~ (property owner) . Mailing Address: Ph: Alt~'I~~1g~i§~ \ .,Jjgli).~;l1 A, HA'{ CDC K 00'50 RIVER,£,END DR. 970·· 984-355i 5 'Contractor: Mailing Address: Ph: Alt Ph: OWNER, . -----' -_ .. __ .. -_ .. , ... , ... 6 Architect /Engineer: Mailing Address: Ph: AltPh: N/A -----... ---.----_ .. 7 Sq. Ft. of Building: Sq. Ft. or Acres of Lot: 14 .. 375 SF Height: 13'-0" No. of Floors: 1 8 Use of Building: P,t::510ENTIA.L DWlSLLIIJEj ~ +0 o/.';,~_ A, .J<> 00. . 9 Describe Work: 20'X 28\ 2~ SToi2.\' ATTAOIEO 0 EiA~A(;,E.·. CT ADD lIVl'\13L1:. $Pt>.ct. OVE~ 10 Class of Work: aNew o Alteration )(Addition II Garage: Ot'Attached Septic; 0 Detached o ISDS ')(Community 12 Driveway Pennit: Owners valuation of Work: $ 50 /}()ti (;-</NOTICE Authority. This application for a Building Pennit must be signed by the Owner of the property, described above, or an authorized agent. If the signature below is not that of the Owner, a separate letter of authority, signed by the Owner, must be provided wilb this Application. Legal Access. A Building Pemlit cannot be issued without proof oftega! and adequate access to the property for pwposes of inspections by the Building Department. Other Permits. Multiple separate pcnnits may be required: (1) State Electrical Permit, (2) County ISDS Pemrit, (3) another pennit required for use on the property identified above, e.g. State or County H.igbway/Road Access or a State Wastewater Discbarge Permit. Void Permit. A Building Permit becomes null and void if the work authorized is not commenced within 180 days of the date of issuance and jf work is suspended or abandoned for a period of ISO days after commencement. CERTIFICATION I hereby certify that I have read this Application and that the information contained above is true and correct. J understand that the Building Department accepts the Application, along with the plans and specifications and olber data submitted by me Of"OJ). my behalf(submittals), based upon my certification as to accuracy. Assmrung completeness of the submittals and approv'al of this Applicatio,n, a Building Permit will be issued granting permission to me, as Owner, to construct the structurc:(s) and facilities detailed on the submittals reviewed by the Building Department. In consideration of the issuance of the Building Pennit, I agrc:c: that I and my agents will comply widl provisions of any federal, state or local law regulating the work and the Garfield County Building Code. ISDS regulations and applicable land use regulations (County Rcgulation(s». I acknowledge that the Building Permit may be suspended or revoked, upon notice from the County, if the location, construction or use of the structu.re(s) and facility(ics), described above, are not in compliance with COtulty RcguJation(s) or any other applicable law. I hereby grant permission to the Building Department to enter the property, described above, to inspect the work. J further aclrnowledge that the issuance of the Building Pennit docs not prevent the Building Official from: (I) requiring the correction of errors in the Submittals, ifany, discovered after issuance; or (2) stopping construction or nse of the structure(s) or fucility(ies) ifsuch is in violation of County ReguJation(s) or any other applicable law. Review of this Application, including submittals, and inspections oflhe work by the Building Department donot constitute an acceptance ofrcsponsibility or liability by the County ofenors, omissions or discrepancies. As the Owner, I acknowledge that responsibility for compliance with federal, state and loca1laws and (',ounty Regulations rest with me and my anthorizcd agents, including without hmltanon my archltC<lt designer, engineer and! or budder ~~6 I HAVE READ AND UNDERSTAND THE NOTICE & CERTIFICATION ABOVE ',~ . 3-/. -09 o SlaNA ' j»)\j:rn I , V STAFF USE ONLY Special Conditions: U7(J76~)( ~ 74,t;;81 +[5610"f;c ~ 1 --'Y~ r S60 . ';(0 Adjusted Valuation: Plan Check Fee: Permit Fee: Manu home Fee: Misc Fees: 4G~tP6. 80 318,74 tPtS • ..p ISDSFee: Total Fees: t4e{) ~id: "5 \ Balance Due: BP No & Issue Date: )SDS No & Issued Date: IO~2 ·1'1 (/;Ofh£J8 11127) '-/.1:3 0'1 Setbacks: OCCGroup: ConstType: p\jl) :!;\~ ~~\ . ~ATE 4J8!oct P~~b\ 4/8/oq APPROVAL DA:rn . The following items are required by Garfield County for a final Inspection: I) A final Electrical Inspection from the Colorado State Electrical Inspector. 2) Permanent address assigned by Garfield County BuildingDepartment and posted at the structure and where readily visible from access road.· ... .. . 3) A finished roof; a lockable building; completed exterior siding; exterior doors and windows installed; a complete kitchen with cabinets, sink with hot & cold running water, non-absorbent kitchen floor covering, counter tops and finished walls, ready for stove and refrigerator; all necessary plumbing. 4) All bathrooms must be complete, with washbowl, tub or shower, toilet, hot and cold running water, non-absorbent floors, walls finished, and privacy door. 5) Steps over three (3) risers, outside or inside must be must have handrails. Balconies and decks over 30" high must be constructed to all !BC and IRC requirements including guardrails. 6) Outside grading completed so that water slopes away from the building; 7) Exceptions to the outside steps, decks, grading may be made upon the demonstration of extenuating circumstances., i.e. weather. Under such circumstances A Certificate of Occupancy may be issued conditionally. 8) A final inspection sign offby the Garfield County Road & Bridge Department for driveway installation, where applicable; as well as any final sign offby the Fire District, and/or State Agencies where applicable. A CERTIFICATE OF OCCUPANCY (C.O.) WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. A C.O. MAY TAKE UP TO 5 BUSINESS DAYS TO BE PROCESSED AND ISSUED. OWNER CANNOT OCCUPY OR USE DWELLING UNTIL A C.O. IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. I understand and agree to abide by the above conditions for occupancy, use and the issuance of a C.O. for the building identified in the Building Permit. GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS For SINGLE F AMIL Y DWELLING CONSTRUCTION Including NEW CONSTRUCTION ADDITIONS ALTERATIONS And MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. When reviewing a plan and it's discovered that required information has not been provided by the applicant, this will result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor shall be required to provide this information before the plan review can proceed. Other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. TWO (2) SETS OF CONSTRUCTION DRAWINGS & TWO (2) SITE PLANS MUST BE SUBMITTEDFOR ALL APPLICATIONS. Please review this documeut to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. Any project with more than ten (10) occupants requires the plans to be sealed by a Colorado Registered Design Professional. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following checklist prior to and during design. Applicants are required to indicate appropriately and to submit the completed checklist at time of application for a permit. Plans to be included for a Building Permit, must be on drafting paper at least 18"x24" aud drawn to scale. Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks, balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line and original grade. A section showing in detai~ from the bottom of the footing to the top of the roof; including re-bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house-rap, (which is required), siding or any approved building material. Engineered foundations may be required. A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. wind speed, wind exposure B or C, and a 36 inch frost depth. All sheets to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be incompliance with the 2003 IRC. 1. Is a site plan included that identifies the location ofthe proposed structure or addition and distances to the property lines from each corner ofthe proposed structure(s) prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Properties with slopes of 30% or greater must be shown on the site plan. (NOTE Section: 106.2) Any site plan for the placement of any portion of a structure within 50 ft. of a property line and not within a previously surveyed building envelope on a subdivision final plat shall be prepared by a licensed surveyor and have the surveyor's signature and professional stamp on the drawing. Any structure to be built within a building envelope of a lot shown on a recorded subdivision plat shall include a copy of the building envelope as it is shown on the final plat with the proposed structure located within the ~velope. Yes_-,,~~_ 2. Does the site plan also include any other buildings on the property, setback easements and utility easements? Please refer to Section 5.05.03 in the Garfield County Zoning Resolution if the property you are applying for a building permit on is located on a comer lot. Special setbacks do apply. /' Yes,_-'V'--__ 3. Does the site plan include when applicable the location of the r.S.D.S. (Individual Sewage Disposal System) and the distances to the property lines, wells (on subject property and adjacent properties), streams or water courses? Yes N/A 4. Does the site plan indicate the location and direction of the County or private road accessing the property? /' Yes, _-,-V __ 2 5. Have you provided any RESOLUTIONS and! or LAND USE PERMlT(S) associated with this property?/Yes if Yes please provide a COPY. NO_-L_~ _ 6. Are you aware that prior to submittal of a building permit application you are required to show proof of a legal and adequate access to the site? This may include (but is not limited to) proof of your right to use a private easement/right of way; A County Road and Bridge permit; a Colorado Dept. of Highway Permit, including a Notice to Proceed; a permit from the federal government or any combination. You can contact the Road & Bridge Department at 625-860 I. See phone book for other agencies ,," Yes v<"" 7. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in acco~e with the IRC or per stamped engineered design? Yes, ___ _ 8. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and earth? Yes ~ No ___ _ 9. Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces and soffits? Yes /No ___ _ 10. Do the plans include design loads as required by Garfield County for roof snow loads, (a minimum of 40 pounds per square foot up to & including 7,000 feet above sea level), floor loads and wind loads?/Yes, ____ _ 11. Does the plan include a building section drawing indicating foundation, wall, floor, and roof construction? /Yes /12. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or joists or trusses? Yes )/13. Does the building section drawing or other detail include the method of positive connection of all columns and beams? Yes /' 14. Does the elevation plan indicate the height of the building or proposed addition from the undisturbed grade to the midpoint between the ridge and eave of a gable or shed roof or the top of a flat roof? (Building height measurement usually not to exceed 25 feet) Yes V''' 3 15. Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase II certifications or phase II EPA certification? Yes N/A No ! ____ 16. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the IRC? 1/"/Yes,_--<N-"./uA,-,-_ No_--'-___ _ 17. Does the plan include a window schedule or other verification that egress/rescue windows from sleeping roomsandlor basements comply with the requirements of the IRC? Yes V 18. Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable rooms? Yes /19. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety glazing for these areas? Yes V-No '------20. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? Yes N /A 21. Do you understand that if you are building on a parcel of land created by the exemption process or the subdivision process, are building plans in compliance with all plat notes and/or covenants? Yes v'" 22. Do you understand that if you belong to a Homeowners Association (HOA), it is your responsibility to obtain written permission from the association, if required by that association, prior to submitting an application for a building permit? The building permit application will be accepted without it, but you run the risk of the HOA bringing action to enforce the covenants, which can result in revocation of permit issued. Additionally, your Plan Review fee is not refundable if the plans have been reviewed by the Building Department prior to any action by the HOA that requires either revocation or substantial modification ofthe plans. Yes V' 23. Will this be the only residential structure on the parcel? Yes V' No Ifno-Explain: _____ _ 24. Have two (2) complete sets of construction drawings been submitted with the application? Yes V 4 25. Do you understang;hat the minimum dimension a home can be on a lot is 20ft.wide and 20ft. long? Yes. _. J<L-"---26. Have you designed or had this plan designed while considering building and other construction code requirements? ° Yes /27. Do your plans comply with all zoning rules and regulations in the County related to your properties zone district? . Yes ,/28. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by the Garfield County Building Department? Yes ,L 29. Do you understand that approval for design and/or construction changes are required prior to the application ofthese changes? Yes /" 30. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application submittal and that you will be required to pay the "Permit Fee" as well as any "Road Impact" or "Septic System" fees required, at the time you pick up your building permit? Yes ,/31. Are you aware that you must call in for an inspection by 3:30 the business day before the requested inspection in order to receive it the following business day? Inspections will be made from 7:30 a.m. to 3:30 p.m. Monday through Friday. Inspections are to be called in to 384-5003. /Yes ,/Noo _____ _ 32. Are you aware that requesting inspections on work that is not ready or not accessible will result in a $50.00 re-inspection fee? Yes ,/33. Are you aware that you are required to call for all inspections required under the IRC including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of the building?:-Yes, _ -'L'--__ 5 34. Are you aware that the Permit Application must be signed by the Owner or a written authority being given for an Agent and that the party responsible for the project must comply with the IRC? Yes \/~. 35. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups, unless you as the homeowner are performing the work? The license number of the person performing the work will be required at time of applicable inspection. Yes .,/' 36. Are you aware, that on the front of the Building Permit Application you will need to fill in the Parcel/Schedule Number for the lot you are applying for this permit on prior to submittal of a building permit aPl'Jication? Your attention in this is appreciated. Yes __-'_<~_ __ 37. Do you know that the local fire district may require you to submit plans for their review of fire safety issues? /' Yes ___" ,/__ (please check with the building department about this requirement) 38. Do you understand that if you are planning on doing any excavating or grading to the property prior to issuance of a building permit that you will be required to obtain a grading permit? Yes Nih 39 . Are you aware that if you will be connecting to a public water and/or sewer system, thit,tc,the tap fees have to be paid and the connections inspected by the service provider prior to the issuance of a Certificate of Occupancy? Yes /" 40. If you anticipate obtaining a water tap from the City of Rifle, please provide a letter indicating that the City will provide water service. No building permit application will be accepted without such a letter. Yes NI AI hereby acknowledge that I have read, understand and answered these questions to the best of my ability. d. .~ :!6-cJ 9 (days); .:..'l-"-..7.,-t1--,9::....>f, f,,-,9,---,,3=--=-~S=--I_ _,( e venings) 6 Pr~ectName:, _ ~R~o~~~~H~A~~~c~o~c~-~~~~A~D~D~i'~i~O~N~ _____________________ __ Project Address:, __-"'OO=5::.0=--'-R'-'i'-'>J'-'e:.=R=B"'8"'N.::.D=----'D"'~__'__, _+ _'-N'-'E.:::.W'-'--"c"'-A""'=-· 'O-L,,,E.=-+i ""=,,",' -_____ _ Notes: If any required information is missing delays in issuing the permit are to be expected. Work may not proceed without the issuance of a permit. If it is determined by the Building Official that additional information is necessary to review the application and plans to determine minimum compliance with the adopted codes, the application may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review, delay in issuance of the permit or delay in proceeding with construction. bpminreqsfJan2009 7 No. 11271 Assessor's Parcel No. 2123-344-02-005 Date 4/13/2009 Btm..DING PERMIT CARD Job Address COSO Riverbend Dr., NewCastle Riverbend SuM. 1st, Blk 2, lot 5 Owner Haycock, Roy Address 0050 Riverbend Dr Phone # 970-618-3523 y-Contractor Owner Address same Phone # 970-984-3551 Setbacks: Front Rear RH LH Zoning ____ _ addt to existing dwelling (2nd story livable INSPECTIONS Soifft~~tover att. Garage) <: • Footing 41~ .. Foundation ?i c1 Grout -'-. ______ _ Un dergro u n d PI u m bi IJ.9 -:-::;;---"--,,,,--:-;0;--Rough Plumbing .:) --It -09' !f37VI Framing 5-0--DC} /G-nL Insulation :s -Ig -oq &iV\ Roofing _---,,=-_=-_~~-=_.,___ Drywall .::;;--"Z-? -0 7' ¢i2. Gas Piping ~ NOTES Weatherproofing ___________ _ Mechanical _____ --::=-____ ---Electrical Rough (State) ;::: 1"7---'7 Electrical inal (State) 11-%--09' Final . ~ /Checklist ,CQm!leted?Z-~ ,s-:-/tt:) Certificate Occupancy # _N'-"-I-I'-'8>--____ _ Date i SeptiC System # __ .L:N~If-1A:I-___ ~ _ _ Date I Final ___________ _ Other ________________ ___ (continue on back) UIL IN PE GARfiELD COUNTY, COLORADO INSPECTiON WILL NOT BE MADE UNLESS THIS CARD is POSTED ONTH!2 JOB Date Issued 4.13.0111<-_____ permitNo.--LI-,-,'\2 :=1-'-11--____ AGREEMENT In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structured for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building department and IMMEDIATELY BECOME NUll AND VOID. Use tldd~ '9.-~ \\OO~te~f.e a-t tlbt~ed .Ja~aef"'-"-· __ AddressorlegalDescription S~ R\Uff"at'ftd dr. ~ t~,--_____ _ Owner \-lav ctI('t Q r.oV Contractor _O,-,b)-=-=-~_~-,--______ _ Building Permit Type reSlG~lal This Card Must Be Posted So It Is Plainly Visible From The Street Until Final Inspection INSPECTION RECORD Footing Driveway ." Foundation I Grouting Insulation S-r{;-Dq /OVII\ Underground Plumbing Drywall s-:-z'l-O? 7Zu? Rough Plumbing Electric final (by State Inspector) 11-<7-I!?( S -/1--oq ;f/fY1 (prior to Final) Rough Mechanical Septic Final 'Y'-<v G.sPiping EINAl -<-z.s--/0 , 1j;":: . _ ~ c-t? .P ,<tv,!'''' C /<!. /"u-1>/A" <-Electric Rough (by State Inspector) (You Must Call For Final Inspection) (Pdo<toF"mlog) Ot-# $(I 2/~1 Notes Framing ;)~(~-fl1 KJm. (to Include Roof in place & Windows & Doors installed & Flrestopping in place) THIS PERMIT IS NOT TRANSFERABLE Fo' Inspection C.11970-384-5003 Office 970-94-5-8212 108 8th Street, Suite 401 Glenwood Springs, Colorado 81601 DO NOT DESTROY THIS CARD PROTECTP:~l~A~~H~~ (DO NOT lAMINATE) COUNTY OF GARFIELD = BUILDING DEPARTMENT CORRECTION NOTICE 108 8th St.,Suite 401 Glenwood Springs, Colorado Phone(970)945~212 Permit No. -/-/1"-----'-'02"'--'-1-'-1_ ___________ I have this day inspected this structure and these premi es and found t e following corrections nee,d ed: • _. o Call for Re-Inspection o $50.00 Re-Inspection Fee must be paid prior to Re-Inspection You are hereby notified that the above correction must be inspected before covering. When correctiol1(s) have been made, cal! for inspection at 970-384-5003. /" t1 Date C, -\1--~ .. 2f 0 I __ ~ Build-in-g-I-n-=sp'-e-c-to--'-r-_-_-_-_-_-_-.·..~.t. -""""'--'--~--"-(ll-'---'7--1-Y_~--'UrJ--",-"---,_---,,,_-____ Phone (970) 945-8212 Apr, 7, 2009 2:01PM The Langford Corpora,! ion No,5471 P, 1 -===::: MAlA ____ S_O_ud_o_r,_M_II_I,_r_&_A_SS_O_'I_.t_e'_'_5_Z9_Z5:... 1 _ (f 1_2:...R_O'_cl_8, _U_lr_" fi,..:-ZI..;,O_'_G_ra_"_d_I'_"'_"_ IO:...O_0' :...0..,:...8_15..,;0_5 T (970) Z43-6067 , (877) 243-6067 • fJix (970)Z41·2845 April 7, 2009 Garfield County Building Department ATTN; Ken Smith 108 8'h Street, Sl. 401 Glenwood Springs, CO 81601 Subject Property: Haycock Residence, 0050 lUver Bend Drive, New Castle, CO 81647 RE: Floor Framing Construction Gentlemen, Please accept this letter as certification oflhe fi'aming design for the aforementioned address, It is acceptable to frame the floor with II 7/8" BCI6000 @16" o,c, . 19'·4" cieal'span and a 2 ft, cantilever to support the roof above. If any questions or concerns arise regarding this consollction, please do not hesitate to contact our office at 970-243·6067. XC: File Parcel Detail Page 1 of 4 Garfield County Assessor/Treasurer Parcel Detail Information AssessorLJreasurer PrgPeJJ)' Search I A;;sesdQLSJJQ;;eLQuery I As;;essor Sa1e.s_.SeNcl1 GlerIL& Re~QH:Lter Rec"pJi9!L:'iearch Parcel Detail I Y.1lille Deti\il I Sal"illeti\il I ResidguJ.illl/Comrmm;iaUmpro..Yem~!1tD_et!!il _Lm1liDetail I photograph;; I Mill Leyy_R.evenuesJ2\;;1ail I Tax Area II Account Number II Parcel Number II 2008 Mill Levy I I 017 II ROl7101 II 212334402005 II 40.758 I Owner Name and Mailing Address IRA YCOCK, ROY A. 150 RlVERBEND DRlVE INEW CASTLE, CO 81647-9776 Assessor's Parcel Description (Not to be used as a legal description) ISECT,TWN,RNO:34-5-90 SUB:RlVERBEND ISUB. 1ST. BLK:2 LOT:5 BK:0522 IpO:0063 BK: 1296 PO: 178 RECPT:590462 IBK:1280 PO:507 RECPT:587152 BK:I020 IpO:0373 BK:0876 PO:0961 BK:0718 , Ipo:0777 Location I I I I I I I I I I Physical Address: 1150 RlVERBEND DR NEW CASTLE I I Subdivision: IIRlVERBEND SUB. 1ST. I I Land Acres: 110 I I Land Sq Ft: 1114,375 I I Section II Townshi[! II Range I I 34 II 5 II 90 I http://www.garcoact.comlassessor/parce1.asp ?Parce IN umber=2123 3440200 5 3/9/2009 Parcel Detail Page 2 of 4 2008 Property Tax Valuation Information I II Actual Value II Assessed Value I 1 Land: II 86,00011 6,8501 I Improvements: II 137,84011 10,9701 I Total: II 223,84011 17,8201 Most Recent Sale Sale Date: 115/30/1997 Sale Price: 11143,500 Basic Building Characteristics N urn ber of Residential 11 1 Buildings: Number of Comm/lnd 10 1 Buildings: I I I Residential Building Occurrence 1 Characteristics I I I I 1 STORY: 111,176 I I TOTAL HEATED AREA: 111,176 I 1 ABSTRACT CODE' II SINGLE F AM.RES-. IMPROVEMTS 1 I ARCHITECTURAL STYLE: Ill-STRY/BSM I I EXTERIOR WALL: IlMASONITE I I ROOF COVER: IlcOMP SHNGL I I ROOF STRUCTURE: IIGABLE I I iNTERIOR WALL: IIDRYWALL I FLOOR: IICARPET I FLOOR: IlsHT VINYL I HEATING FUEL: IIELECTRIC I HEATING TYPE: IIELEC BS BD I STORIES: IISTORIES 1.0 I I BATHS: 111.7 I I II I http://www. garcoact. coru! assessor/parcel.asp ?ParcelN umber=2123 3440200 5 3/9/2009 Parcel Detail Page 3 of 4 I ROOMS: 115 I I UNITS: III I I BEDROOMS: 113 I I YEAR BUILT: 111978 I Tax Information I Tax Year II Transaction Type II Amount I I 2008 II Tax Payment: First Half II ($363.16)1 I 2008 II Tax Amount II $726.321 I 2007 II Tax Payment: Second Half II ($356.00)1 I 2007 II Tax Payment: First Half II ($356.00}1 I 2007 II Tax Amount II $712.001 I 2006 II Tax Payment: Second Half II ($292.76}1 I 2006 II Tax Payment: First Half II ($292.76)1 I 2006 II Tax Amount II $585.521 I 2005 II Tax Payment: Second Half II ($293.00)1 I 2005 II Tax Payment: First Half II ($293.00}1 I 2005 II Tax Amount II $586.001 I 2004 II Tax Payment: Second Half II ($355,03}1 I 2004 II Tax Payment: First Half II ($355,03)1 I 2004 II Tax Amount II $710.061 I 2003 II Tax Payment: Second Half II ($399.1621 I 2003 II Tax Payment: First Half II ($399.1621 I 2003 II Tax Amount II $798.321 I 2002 II Tax Payment: Second Half II ($412.62)1 I 2002 II Tax Payment: First Half II ($412.6221 I 2002 II Tax Amount II $825.241 2001 II Tax Payment: Second Half II ($410.2321 2001 II Tax Payment: First Half II ($410.23)1 2001 II Tax Amount II $820.461 2000 II Tax Payment: Second Half II ($367.68)1 I 2000 II Tax Payment: First Half II ($367.68)1 2000 II Tax Amount II $735.361 1999 II Tax Payment: Second Half II ($365.74)1 1999 II Tax Payment: First Half II ($365.74}1 1999 II Tax Amount II $731.481 http://www.garcoact.com/assessor/parcel .asp?ParceIN umber=2123 3440200 5 3/9/2009