HomeMy WebLinkAbout1.28 Telecom. Facility Standards) .~, m~~~~ IO}8 COUNTY Rd }2} ~' Rifl E, CO 816~O Williams Production RMT Company LLC TR 41-35-597 Communications Site Limited Impact Review Permit Application Submittal Item Tab 42-Additional
Standards Applicable to Telecommunications Facilities. Section 7-823 A. Shared Facilities-Please see Tab 2-Project Overview attachment "TR 4 1-35-597-Communications Site" memorandum
dated 2/16/11, authored by Bill Foote-Information Technology Project Manager for Williams Production RMT Company LLC. This memo notes the engineering details surrounding the need for
this facility and for this specific location. This facility will not be a shared facility. B. New Towers and Facilities-Please see Tab 2-Project Overview attachment "TR 41-35-597-Communications
Site" memorandum dated 2/16/1 1, authored by Bill Foote-Information Technology Project Manager for Williams Production RMT Company LLC. This memo notes the engineering details surrounding
the need for this facility and for this specific location. This facility will not be a shared facility. This letter and information meets the burden of proof required in Section 7-823
B. I., B.2, and B.4. B.3 is dealt with below in item D. In conclusion, there are no ex isting communications fac ilities that can be utilized for this communications facility. C. Structural
and Engineering Standards-Please find attached a Structural Design Report prepared by Sabre Tower & Poles dated 6129/11 and sealed by Colorado Professional Engineer #39923-Amy Herbst.
This design takes into account the necessary loads and tower calculations. Additionally, the design includes a foundation design that is prepared utilizing the tower structural calculations
and the geotechnical report provided in this application in Tab 13-Impact Analysis-Section 4-Soil Characteristics. Page 1 of 3
D. Interference-Williams Production RMT Company LLC will ensure that all transmitting systems designed and installed will meet or exceed the Federal Communications Commission radiofrequency
safety requirements. Installations where the safety requirements might be compromised will be placarded accordingly and restricted to authorized personnel. Further reference is available
with the following attached document "Questions and Answers about Biological Effects and Potential Hazards of Radiofrequency Electromagnetic fields dated August 1999. E. Health Standards:
Williams Production RMT Company LLC will ensure all transmitting system are well within the power guidelines as directed in Part 15 and Part 90 of the FCC regulations. F. Public Utility
Structures-Not applicable. G. Design, Materials and Color-The communications facility has been designed to minimize visual impact. The solar panels on the roof will be dark black. The
tower color will be galvalume and the building color will be dark tan. Standards I, 2, 3, 4 and 5 within Section G are not applicable for this installation as these standards deal with
antennas installed on existing buildings. H. Landscaping and screening-Please see Tab 11-Landscape Plan for information. r. Lighting and signage-No lighting will be included on the tower.
Sign age will not be installed at the site. J. Telecommunications Facility Equipment BuiJding-Please see Tab 32-Building Design for information. K. Modification or Demolition-This will
be complied with. L. Maintenance-This will be complied with. M. Review-The Director of the Planning Department will review the facility 2 years after installation to verify compliance
with the ULUR. N. Abandonment-This will be complied with. O. FAA Form 7460-1-Notice of Proposed Construction or AlterationThis form needs to be filed if: I. New construction or alteration
exceeding 200 ft above ground level 2. any construction or alteration: Page 2 of 3
* within 20,000 ft of a public use or military airport which exceeds a 100: I surface from any point on the runway of each airpOlt with its longest runway more than 3,200 ft *within
10,000 ft of a public use or military airport which exceeds a 50: I surface from any point on the runway of each airport with its longest runway no more than 3,200 ft *within 5,000 ft
ofa public use heliport which exceeds a 25:1 surface 3. any highway, railroad or other traverse way whose prescribed adjusted height would exceed the above noted standards 4. when requested
by the FAA 5. any construction or alteration located on a public use airport or heliport regardless of height or location. In summary, this project is not required to file FAA form 7460-1.
Thank you for your assistance on this project. Please contact me with any questions. Sincerely ) ~G.~~ Philip B. Vaughan President PVCMI-Land Planning Division Page 3 of 3
Sabre'· Towers & Poles Structural Design Report 80' S3TL Series HD1 Self-Supporting Tower located at: Parachute, CO prepared for: THIN AIR COMMUNICATIONS INC by: Sabre Towers & Poles
™ Job Number: 46087 June 29, 2011 Tower Profile. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Foundation Design Summary (Option
1). . . . . . . . . . . . . . . . . . . • . . . . . . . . . . 2 Foundation Design Summary (Option 2). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Maximum Leg Loads. .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Maximum Diagonal Loads. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . 5 Maximum Foundation Loads. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Calculations. . . . . . . . . . . . • . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . .. A1-A10 Tower by ~~ Foundation by &rk Approved by a~ ~~---------
i ~ -~ .. 'il ~ 4i ~ ~ ~ ~ .§' ·~s ~a ~ ~§ ] Project: c: \Output\S3TLHDl \-~ 608? . LOO I~'S TaobnlSr' ePo·/e,-_ ././.~ /«~::::::::: ..... 'WI NOTES: t:'"""""The tower moMl is 53TL Serie~
lID:. 2. Tral'lsoission lines are to be attached to stdndard 6 hole waveguide ladders. 3, Azimuths are rehLive (not based on true north). 4. !O~ndatlon loads sllol/o are mal<irnu!'l~.
5. (~I I" dia. FlSS4 grade 105 anchor bolts per leg. Mi~imum ]5,S" embedment from top of concrete to top of nut. 6, All unequal angles are oriented wlth the short leg vertical. 7, This
tower was desiqned for Structure Class II, Exposure Cateqory C and Topographlc Cate<;lory 4, with a Crest Height of 300'. a. 1'~e foundation loads shOl/1I belo" are lactored loads. ANTENNA
LIST NO ELEV A.~nNNA (2) J3589-'I' 12( 3ft Sidearms ''"" SO' M.>.TEIUAL LIST NO TYPE 12( (2) 121 " 2·x2"xl/B" e 2·y.2"~)/16" S' H. P. Dish TMA 2' Yagi n·LrNE 12( LMR 600 12( LMR-400
12( L~R 600 TOTAL FOUNDATION lOADS H=21.68 k INDIVIDUAL FOOTING LOADS H=12,53 k V=12.28 k H=1097.96 t.-ft '1'=-13.53 It-ft V=136.72 k. tJ:::::-139.19 It Sabre Communications Corporation
2101 Murray Street (P.O. Box 658), Sioux City, Iowa 51102-0658 Phone: (712) 258-6690 Fax; (712) 258-8250 Client: THIN AIR CQIoH./NICATIONS INC Job No: 46087 Date: 28 jun 2(. Location:
Parachute, CO Total Hei.ght, 80.00' Tower Height: eo.oo' Standard: 'rIA 222-G-200S OOdqn Wind' Ice: gOrnph 0" ice' 50mph 0.25" lCIIII Sheet: 1
Two (2) #4 ties within top 5" of concrete Sabre'· Towers & Poles No.: 46087 Page: 2 Date: 6/29/11 By: ARH Customer: THIN AIR COMMUNICATIONS INC Site: Parachute, CO 80 ft. Model S3TL
Series HD1 Self Supporting Tower At 90 mph Wind with no ice and 50 mph Wind with 0.25 in. Ice per ANSIITIA-222-G-2005. Antenna Loading per Page 1 1 1 1 1 1 1------1 1 1 1 1 1 1 ,-----1
I 1 1 1 1> -_-___ 11 1 1 1 1 1i -----'1 1 1 1 _____ ...1 ELEVATION VIEW (4.09 Cu. Yd •. each) (3 REQUIRED; NOT TO SCALE) Pier Notes: 1). Concrete shall have a minimum 28-day compressive
strength of 4000 PSI, in accordance with ACI318-05. 2). Rebars to conform to ASTM specification A615 Grade 60. 3). All rebar to have a minimum of 3" concrete cover. 4). All exposed concrete
corners to be chamfered 3/4". 5). The foundation design is based on the geotechnical report by Terracon, project no. AD114029, dated June 20, 2011. 6). See the geotechnical report for
drilled pier installation requirements, if specified. 7). The foundation is based on the following factored loads: Factored uplift (kips) = 139.19 Factored download (kips) = 136.72 Factored
shear (kips) = 12.53 8). This is a design drawing only. Please see final construction drawings for all installation details Rebar Schedule per Pier (8) #7 vertical rebar w/#4 ties, two
(2) within top 5" of pier then 12" C/C Information contained herein is the sale property of Sabre Towers & Poles. constitutes a trade secret as defined by Iowa Code Ch. 550 and shall
not be reproduced, copied or used in whole or part for any purpose whatsoever without the prior written consent of Sabre Towers & Poles. 2101 Murray SI-P.O. Box 658 -Sioux City, IA 51102-0658
-Phone 712.258.6690 -Fax 712.258.8250
Sabre'· No.: 46087 Page: ~ Date: 6/29/11 Towers & Poles By: ARH Customer: THIN AIR COMMUNICATIONS INC Site: Parachute, CO 80 ft. Model S3TL Series HD1 Self Supporting Tower At 90 mph
Wind with no ice and 50 mph Wind with 0.25 in. Ice per ANSIITIA-222-G-2005. ( ( Antenna Loading per Page 1 Center of Tower '\ q /\ M \ , /\ en /\ /\ /\ //I \ I \ I \ \ d------M 1-------0
, <n 9'-3" ) ( 18'-6" PLAN VIEW Grade 9'-3" ) ) Two(2) #4 ties within top 5" of concrete ~ 0) ~ Notes: 1). Concrete shall have a minimum 28-day compressive strength of 4000 PSI, in accordance
with ACI 318-05. 2). Rebar to conform to ASTM specification A615 Grade 60. 3). All rebar to have a minimum of 3" concrete cover. 4). All exposed concrete corners to be chamfered 3/4".
5). The foundation design is based on the geotechnical report by Terracon, project no. AD114029, dated June 20, 2011 . 6). This design requires 2' of Engineered Fill cO 7). See the geotechnical
report for 101 below the base of the mat. -----lr--;;-compaction requirements, if specified. 1~ 18'-6" ELEVATION VIEW (20.65 Cu. Yds.) 1 REQD.; NOT TO SCALE) V//.1 II Pier Mat 8). The
foundation is based on the fo llowing factored loads: Factored download (kips) = 6.64 Factored overturn (kip-tt) = 1097.96 Factored shear (kips) = 21 .68 9). This is a design drawing
only. Please see final construction drawings for all installation details Rebar Schedule per Mat and per Pier (8) #6 vertical rebar wlhooks at bottom w/#4 Rebar ties, two (2) within
top 5" of pier then 12" CIC (20) #6 horizontal rebar evenly spaced each way top and bottom. (80 total) Information contained herein is the sole property of Sabre Towers & Poles, constitutes
a trade secret as defined by Iowa Code Ch. 550 and shall not be reproduced, copied or used in whole or part for any purpose whatsoever without the prior written consent of Sabre Towers
& Poles. 2101 Murray St -P.O.Box 658 -Sioux City. IA 51102-0658 -Phone 712.258.6690 -Fax 712.258.8250 )
DrawResults Copyright (C) Guymast Inc. 2010 Phone: (416) 736-745 Licensed to: Sabre Communications Corporation 28 jun 2011 9:46:55 : Maximum Elev(ft) 80.0 72 64 56 48 40 32 24 16 8 o
· · · · · · · Compression in Legs (kip) 140 120 100 80 60 40 20 I I I I I I 1 31.5 , I .. _. --~ ;-, r-, 74.4 , r,i I_ ,[ ! , .J.. ~ 111.0 rj :-: r-, ~42~1 I T ' 1 'I 1 1 I 140 120 100
80 60 40 20 Project: c:\output\S3TLHD1\460B7.MST Tension in Legs (kip) o 20 40 60 80 100 120 140 160 180 1 1 1 , 1 I I I I J 80.0 ! j . , 72 4B.2 i I ..... ! ! 64 L-. , 56 '--'--101.3
48 i.--, ! , -, 40 ,, -, , 32 ,i 135.9 '-r 24 1 I 16 165.6 ! r 8 i ! , I I I I I T'-T T o o 20 40 60 80 100 120 140 160 180
DrawResu1ts Copyright (C) Guymast Inc. 2010 Phone: (416) 736-745 Licensed to: Sabre Communications Corporation I Maximum E1ev (ft) 80.0 72 64 56 48 40 32 24 16 8 o Compression in Diagonals
(kip) 10 5 •. I I , i i , , 9. 6 ~ , ! r-! i I , 6.4 i ~,6 , I I I 10 5 Project: C:\Output\S3TLHD1\46087,MST o --o Tension in Diaqonals (kip) 5 I r--r-, i , , r , i I 5 28 jun 2011 9:46:55
10 I r 80.0 ,. 72 64 9.6 · 56 ~ 48 . t-40 ~ 32 6.4 24 . · 16 5.6 · 8 I o 10 '5
DrawResults Copyright (C) Guymast Inc. 2010 Phone: (416) 736-745 Licensed to: Sabre Communications Corporation Maximum TOTAL FOUNDATION LOADS (kip, ft-kip) INDIVIDUAL FOOTING LOADS (kip)
Project: C:\Output\S3TLHD1\46087.MST t -13.53 ~.96 12.28~ ~ 21.68 1 12.52 10.22 --f!:J 139. 19i J136.72 c~Cb 12.53 28 jun 20ll 9:46:55
46087.txt =============================================================================== MAST -Latticed Tower Analysis (unguyed) (c)1997 Guymast Inc. 416-736-7453 processed under license
at: sabre communications corporation on: 28 jun 2011 at: 9:44:48 =============================================================================== MAST GEOMETRY ( ft ) ====================
PANEL NO.OF ELEV.AT ELEV.AT F.W .. AT F.W .. AT TYPICAL TYPE LEGS BOTTOM TOP BOTTOM TOP PANEL HEIGHT X 3 75.00 80.00 5.00 5.00 5.00 X 3 60.00 75.00 5.00 5.00 5.00 X 3 55.00 60.00 5.00
5.00 5.00 X 3 40.00 55.00 5.00 5.00 5.00 X 3 35.00 40.00 5.50 5.00 5.00 X 3 20.00 35.00 7.00 5.50 5.00 X 3 0.00 20.00 9.00 7.00 5.00 MEMBER PROPERTIES ================= MEMBER BOTTOM
TOP X-SECTN RADIUS ELASTIC THERMAL TYPE ELEV ELEV AREA OF GYRAT MODULUS EXPANSN ft ft in. sq in ksi /deg LE 60.00 80.00 1.075 0.787 29000. 0.0000116 LE 40.00 60.00 2.254 0.787 29000.
0.0000116 LE 20.00 40.00 3.016 0.787 29000. 0.0000116 LE 0.00 20.00 3.678 0.787 29000. 0.0000116 DI 40.00 80.00 0.715 0.617 29000. 0.0000116 01 0.00 40.00 0.484 0.617 29000. 0.0000116
HO 75.00 80.00 0.715 0.617 29000. 0.0000116 HO 55.00 60.00 0.715 0.617 29000. 0.0000116 HO 35.00 40.00 0.484 0.617 29000. 0.0000116 FACTORED MEMBER RESISTANCES ===========================
BOTTOM TOP LEGS DIAGONALS HORIZONTALS INT BRACING ELEV ELEV COMP TENS COMP TENS COMP TENS COMP TENS ft ft kip kip ki p ki p kip kip kip kip 75.0 80.0 31.48 48.15 9.58 9.58 8.46 8.46
0.00 0.00 60.0 75.0 31.48 48.15 9.58 9.58 0.00 0.00 0.00 0.00 55.0 60.0 74.39 101. 25 9.58 9.58 8.46 8.46 0.00 0.00 40.0 55.0 74.39 101. 2S 9.58 9.58 0.00 0.00 0.00 0.00 35.0 40.0 110.98
135.90 6.39 6.39 5.82 5.82 0.00 0.00 20.0 35.0 110.98 135.90 6.39 6.39 0.00 0.00 0.00 0.00 0.0 20.0 142.05 165.60 5.63 5.63 0.00 0.00 0.00 0.00 =======================================================
========================= * only 3 condition(s) shown in full • some concentrated wind loads may have been derived from full-scale wind tunnel testing page A1
,-----------~ --~--46087.txt LOADING CONDITION A ========================================================= 90 mph wind with no ice. wind Azimuth: Oh MAST LOADING ============ LOAD ELEV
APPLY .. LOAD .. AT LOAD TYPE RADIUS AZI AZI ft ft C 75.0 0.00 0.0 0.0 C 66.0 0.00 0.0 0.0 C 50.0 0.00 0.0 0.0 C 50.0 0.00 0.0 0.0 D 80.0 0.00 0.0 0.0 D 75.0 0.00 0.0 0.0 D 75.0 0.00
0.0 0.0 D 60.0 0.00 0.0 0.0 D 60.0 0.00 0.0 0.0 D 55.0 0.00 0.0 0.0 D 55.0 0.00 0.0 0.0 D 40.0 0.00 0.0 0.0 D 40.0 0.00 0.0 0.0 D 35.0 0.00 0.0 0.0 D 35.0 0.00 0.0 0.0 D 20.0 0.00 0.0
0.0 D 20.0 0.00 0.0 0.0 D 0.0 0.00 0.0 0.0 ANTENNA LOADING =============== ....... ANTENNA ....... ATTACHMENT TYPE ELEV AZI RAD AZI ft ft HP 66.0 0.0 4.4 0.0 HP 66.0 0.0 4.4 120.0 SUPPRESS
PRINTING ================= ... FOR THIS LOADING .. LOADS DISPL MEMBER FOUNDN INPUT FORCES LOADS no yes yes yes .... . . FORCES ...... ...... MOMENTS ...... HORIZ DOWN VERTICAL TORSNAL
kip ki P ft-kip ft-ki p 1.03 0.39 0.00 0.00 0.04 0.02 0.00 0.00 0.29 0.07 0.00 0.00 0.29 0.07 0.00 0.00 0.12 0.05 0.00 0.00 0.12 0.05 0.00 0.00 0.13 0.05 0.01 0.06 0.13 0.05 0.01 0.06
0.16 0.07 0.01 0.06 0.16 0.07 0.01 0.06 0.14 0.06 0.01 0.06 0.14 0.06 0.01 0.07 0.16 0.07 0.01 0.07 0.16 0.07 0.01 0.07 0.15 0.06 0.01 0.07 0.16 0.07 0.01 0.07 0.16 0.07 0.02 0.07 0.17
0.08 0.01 0.06 ........... ANTENNA FORCES .......... AXIAL SHEAR GRAVITY ki P kip kip 4.06 0.00 0.54 4.06 0.00 0.54 . ........ MAXIMUMS ......... . ALL DISPL MEMBER FOUNDN FORCES LOADS
no no no no TORSION ft-kip 0.00 0.00 ================================================================================ LOADING CONDITION M =========================================================
90 mph wind with no ice. wind Azimuth: 0= page A2
MAST LOAOING ::;;;;:;;:==::;::;;::;;;:;::== LOAO ELEV APPLY .. LOAD .. AT LOAD TYPE RADIUS AZI AZI ft ft C 75.0 0.00 0.0 0.0 C 66.0 0.00 0.0 0.0 C 50.0 0.00 0.0 0.0 C 50.0 0.00 0.0 0.0
D BO.O 0.00 0.0 0.0 D 75.0 0.00 0.0 0.0 D 75.0 0.00 0.0 0.0 D 60.0 0.00 0.0 0.0 D 60.0 0.00 0.0 0.0 D 55.0 0.00 0.0 0.0 D 55.0 0.00 0.0 0.0 D 40.0 0.00 0.0 0.0 D 40.0 0.00 0.0 0.0 D
35.0 0.00 0.0 0.0 D 35.0 0.00 0.0 0.0 D 20.0 0.00 0.0 0.0 D 20.0 0.00 0.0 0.0 D 0.0 0.00 0.0 0.0 ANTENNA LOADING =============;:;:;:: ....... ANTENNA ....... ATTACHMENT TYPE ELEV AZI
RAD AZI ft ft HP 66.0 0.0 4.4 0.0 HP 66.0 0.0 4.4 120.0 SUPPRESS PRINTING ================= ... FOR THIS LOADING .. LOADS DISPL MEMBER FOUNDN INPUT FORCES LOADS no yes yes yes 460B7.txt
...... FORCES ...... . ..... MOMENTS ...... HORIZ DOWN VERTICAL TORSNAL ki P ki p ft-kip ft-kip 1.03 0.29 0.00 0.00 0.04 0.01 0.00 0.00 0.29 0.05 0.00 0.00 0.29 0.05 0.00 0.00 0.12 0.04
0.00 0.00 0.12 0.04 0.00 0.00 0.13 0.03 0.01 0.06 0.13 0.03 0.01 0.06 0.16 0.05 0.01 0.06 0.16 0.05 0.01 0.06 0.14 0.05 0.01 0.06 0.14 0.05 0.01 0.07 0.16 0.05 0.01 0.07 0.16 0.05 0.01
0.07 0.15 0.05 0.01 0.07 0.16 0.05 0.01 0.07 0.16 0.06 0.01 0.07 0.17 0.06 0.01 0.06 ........... ANTENNA FORCES .......... AXIAL SHEAR GRAVITY kip kip kip 4.06 0.00 0.40 4.06 0.00 0.40
. ........ MAXIMUMS ......... . ALL DISPL MEMBER FOUNDN FORCES LOADS no no no no TORSION ft-kip 0.00 0.00 ===========================::;;====::;;========================================::;;======
LOADING CONDITION Y ========================================================= 50 mph wind with 0.25 ice. wind Azimuth: 0= MAST LOADING =======;:;==== LOAD TYPE ELEV APPLY .. LOAD ..
AT RADIUS AZI ft ft LOAD AZI ...... FORCES ..... . HORIZ DOWN ki p ki p page A3 ...... MOMENTS ..... . VERTICAL TORSNAL ft-kip ft-kip
C 75.0 0.00 0.0 0.0 C 66.0 0.00 0.0 0.0 C 50.0 0.00 0.0 0.0 C 50.0 0.00 0.0 0.0 D 80.0 0.00 0.0 0.0 D 75.0 0.00 0.0 0.0 D 75.0 0.00 0.0 0.0 D 60.0 0.00 0.0 0.0 D 60.0 0.00 0.0 0.0 D
55.0 0.00 0.0 0.0 D 55.0 0.00 0.0 0.0 D 40.0 0.00 0.0 0.0 D 40.0 0.00 0.0 0.0 D 35.0 0.00 0.0 0.0 D 35.0 0.00 0.0 0.0 D 20.0 0.00 0.0 0.0 D 20.0 0.00 0.0 0.0 D 0.0 0.00 0.0 0.0 ANTENNA
LOADING =============== ....... ANTENNA ....... ATTACHMENT TYPE ELEV AZI RAD AZI ft ft HP 66.0 0.0 4.4 0.0 HP 66.0 0.0 4.4 120.0 SUPPRESS PRINTING ================= ... FOR THIS LOADING
.. LOADS DISPL MEMBER FOUNDN INPUT FORCES LOADS no yes yes yes 46087.txt 0.29 0.55 0.00 0.00 0.01 0.02 0.00 0.00 0.09 0.09 0.00 0.00 0.09 0.09 0.00 0.00 0.03 0.09 0.00 0.00 0.03 0.09
0.00 0.00 0.04 0.09 0.03 0.02 0.04 0.09 0.04 0.02 0.04 0.12 0.04 0.03 0.04 0.12 0.04 0.03 0.04 0.11 0.04 0.03 0.04 0.11 0.05 0.03 0.05 0.13 0.05 0.03 0.05 0.13 0.05 0.03 0.05 0.11 0.05
0.03 0.05 0.12 0.04 0.03 0.05 0.13 0.06 0.03 0.06 0.14 0.08 0.04 ........... ANTENNA FORCES .......... AXIAL SHEAR GRAVITY kip kip kip 0.81 0.00 1. 25 0.81 0.00 1. 25 . ........ MAXIMUMS
... , ..... . ALL DISPL MEMBER FOUNDN FORCES LOADS no no no no TORSION ft-ki p 0.00 0.00 ================================================================================ MAXIMUM MAST
DISPLACEMENTS: =========================== ELEV ------DEFLECTIONS (ft)-------TILTS (DEG)---TWIST ft NORTH EAST DOWN NORTH EAST DEG 80.0 -0.893 A 0.647 J 0.007 A -1. 026 A 0.742 J -0.522
B 75.0 -0.804 A 0.582 J 0.006 A -1.026 A 0.741 J -0.522 B 70.0 -0.714 A 0.517 J 0.005 A -1. 022 A 0.737 J -0.522 B 65.0 -0.624 A 0.453 J 0.004 A -1. 006 A 0.723 J -0.513 B 60.0 -0.536
A 0.389 J 0.003 A -0.964 A 0.692 J -0.464 B 55.0 -0.451 A 0.328 J 0.003 A -0.923 A 0.662 J -0.416 B 50.0 -0.373 A 0.272 J 0.002 A -0.858 A 0.617 J -0.369 B 45.0 -0.296 A 0.217 J 0.002
A -0.772 A 0.556 J -0.322 B 40.0 -0.232 A 0.171 J 0.001 Y -0.658 A 0.475 J -0.275 B 35.0 -0.175 A 0.130 J 0.001 Y -0.565 A 0.410 J -0.215 B 30.0 -0.130 A 0.097 J 0.001 Y -0.474 A 0.345
J -0.167 B 25.0 -0.090 A 0.067 J 0.001 Y -0.381 A 0.279 J -0.127 B 20.0 -0.060 A 0.045 J 0.001 Y -0.291 A 0.213 J -0.094 B 15.0 -0.035 A 0.027 J 0.001 Z -0.217 A 0.160 J -0.066 B Page
A4
10.0 5.0 0.0 -0.019 A 0.005 G 0.000 A 0.014 J -0.004 D 0.000 A 46087.txt 0.000 9 -0.145 A 0.000 Z -0.071 A 0.000 A 0.000 A MAXIMUM ANTENNA AND REFLECTOR ROTATIONS: ===================================
==== 0.107 J 0.053 J 0.000 A -0.041 B -0.019 B 0.000 A ELEV ft AZI TYPE deg * ........ BEAM OEFLECTIONS (deg) ....... . PITCH YAW ROLL TOTAL 66.0 66.0 0.0 HP 0.0 HP -0.726 J -0.726 J
MAXIMUM TENSION IN MAST MEMBERS (kip) ===================================== ELEV ft LEGS DIAG 80.0 ---------------------0.06 U 0.48 L 75.0 ---------------------1.24 M 1.03 T 70.0 --------------------
-4.75 M 2. SO X 65.0 ---------------------13.01 M 8.64 A 60.0 ---------------------26.40 M 7.72 M 55.0 ---------------------41.86 M 7.76 L 50.0 ---------------------56.41 M 8.43 X 45.0
---------------------74.04 M 8.61 L 40.0 ---------------------85.90 M 5.86 M 35.0 ---------------------95.85 M 5.10 F 30.0 ---------------------102.49 M 4.97 M 25.0 ---------------------110.75
M 4.58 F 20.0 ---------------------116.89 M 4.48 M 15.0 ---------------------124.12 M 4.34 F 10.0 ---------------------129.93 M 4.27 X 5.0 ---------------------136.54 M 4.27 F 0.0 -------------------
--0.509 B 0.509 B HORIZ 0.21 R 0.04 G 0.03 M 0.05 G 1. 74 N 0.14 A 0.05 S 0.14 A 0.72 S 0.10 A 0.00 A 0.08 A 0.01 A 0.05 A 0.01 S 0.04 A 0.00 A MAXIMUM COMPRESSION IN MAST MEMBERS (kip)
page A5 1.009 A 1.009 A BRACE 0.00 A 0.00 A 0.00 A 0.00 A 0.00 A 0.00 A 0.00 A 0.00 A 0.00 A 0.00 A 0.00 A 0.00 A 0.00 A 0.00 A 0.00 A 0.00 A 0.00 A 0.794 P 0.794 P
46087.txt ELEV LEGS DIAG HDRIZ ft 80.0 ----------------------0.24 L -0.17 B -0.44 R 75.0 ----------------------0.03 X -1. 74 K -1.07 B 70.0 ----------------------0.03 H -5.46 G -2.52
F 65.0 ----------------------0.05 X -14.26 G -7.40 R 60.0 ----------------------1. 75 C -25.92 G -7.45 L 55.0 ----------------------0.12 S -40.37 G -7.90 X 50.0 ----------------------0.05
A -53.83 G -8.31 L 45.0 ----------------------0.12 S -70.59 G -8.67 X 40.0 ----------------------0.84 A -81. 82 G -5.53 F 35.0 ----------------------0.09 S -91. 73 G -5.23 M 30.0 --------------------
-0.00 S -98.37 G -4.81 F 25.0 ----------------------0.07 S -106.77 G -4.57 M 20.0 ----------------------0.01 S -113.10 G -4.44 F 15.0 ----------------------0.05 S -120.65 G -4.32 X 10.0
----------------------0.01 A -126.81 G -4.29 F 5.0 ----------------------0.03 S -133.84 G -4.25 X 0.0 ---------------------0.00 A MAXIMUM INDIVIDUAL FDUNDATION LOADS: (kip) ==========================
================ --------------LOAD---COMPONENTS------------NORTH EAST DOWN UPLI FT 12.52 G -10.22 c 136.72 G -139.19 M MAXIMUM TOTAL LOADS ON FOUNDATION : (kip & kip-ft) ============================
====================== BRACE 0.00 A 0.00 A 0.00 A 0.00 A 0.00 A 0.00 A 0.00 A 0.00 A 0.00 A 0.00 A 0.00 A 0.00 A 0.00 A 0.00 A 0.00 A 0.00 A 0.00 A TOTAL SHEAR 12.53 G ------HORIZONTAL-----DOWN
---------OVERTURNING---------NORTH EAST TOTAL NORTH EAST TOTAL @180.0 @180.0 -21. 7 17.2 21. 7 12.3 -1098.0 819.0 1098.0 A J A j A J A TORSION -13.5 B ================================================
=============================== page A6
DRILLED STRAIGHT PIER DESIGN BY SABRE TOWERS & POLES Tower Description BO' S3TL Series HD1 Customer Name THIN AIR COMM UNICATIONS INC Job Number 46087 Date 6/29/2011 Engineer ARH Factored
Uplift (kips) Factored Download (kips) Factored Shear (kips) Ultimate Bearing Pressure Bearing <!>s Bearing Design Strength (ksf) Water Table Below Grade (tt) Bolt Circle Diameter (in)
Top of Concrete to Top of Bottom Threads (in) Pier Diameter (ft) HI. Above Ground (tt) Pier Length Below Ground (tt) Quantity of Bars Bar Diameter (in) Tie Bar Diameter (in) Spacing
oITies (in) Area of Bars (in2) Spacing of Bars (in) fc (ksi) fy (ksi) Unit WI. of Concrete (kcf) Download Friction <!>s Uplift Friction <!>s Volume of Concrete (yd') Skin Friction Factor
for Uplitt 1 Ignore Bottom Length in Download? Depth at Bottom of Layer (tt) ,4 9 .. . . . .30 . .. ' 0 . 0.· . '. .' 0 . ", 0 ...... :.: ; ,'. o· 0 --,/'" ,.~ . . 0 Download: Factored
Net Weight of Concrete (kips) Bearing Design Strength (kips) Skin Friction Design Strength (kips) Download Design Strength (kips) " 139.19 136.72 . 12.53 0 '0.&" a 9 '. . 9 .35.5 2.5
0.5 22 , 8 , '" 0.875 0.5. 12 4.B1 8.69 4' " , .. ' 60 0;15 .0:55 ,-' ,0.55 4,09 1 0 UII. Skin Friction (Ik s 0.00 '0.00 9,50 0.00 0.00 0.00 • 0.00 . 0.00 " 0.00 ....• 0.00 0.4 0.0 533,5
-"·"j~c1. ~"! Anchor Bolt Count (per leg) 4 Minimum Pier Diameter (It) I: '~,2§A Minimum Area of Steel (in2) 1 "t';3',S:tl.J Length to Ignore Download (ft) o (kcf) 0.11 0.115 0.15 o
o o o o o o Factored Net Download (kips) H;l7:<2: p.A1
DRILLED STRAIGHT PIER DESIGN BY SABRE TOWERS & POLES (CONTINUED) Uplift: Nominal Skin Friction (kips) Wc, Weight of Concrete (kips) WR, Soil Resistance (kips) ¢s(Wr+Wc) (kips) Uplift
Design Strength (kips) Pier Design: Design Tensile Strength (kips) $Vn (kips) $Vc=$2(1+N,/(500Ag))f c"2bwd (kips) V, (kips) Maximum Spacing (in) Anchor Bolt Pull·Out: W c=$1..(2/3)f
c 112(2 .8AsLOPE+ 4AFLA T) Rebar Development Length (in) Condition Download Uplift Area of Steel Shear Anchor Bolt Pull·Out Interaction Dia ram Visual Check 979.8 12.6 511.9 288.5 1
is OK, 0 Fails 1 1 1 1 1 1 Factored Uplift (kips) Tu (kips) V, (kips) ••• V, max = 4 fc"2bwd (kips) (Only if Shear Ties are Required) ••• Ref. ACI11.5.5 & 11.5.6.3 1.139,2.1 r.>\~~.
:1 " +~;-' P, (kips) "'''Ollll".n Length of Development (inj~~tJ
MAT FOUNDATION DESIGN BY SABRE TOWERS & POLES Tower Description 80' S3TL Series HD1 Customer THIN AIR COMMUNICATIONS INC Project Number 46087 Date 6/29/2011 Engineer ARH Overall Loads:
109.7.96 Anchor Bolt Count (per leg) I 6:64 .. Factored Moment (ft-kips) 4 Factored Axial (kips) Factored Shear (kips) Individual Leg Loads: I • 21.68 Tower eccentric from mat (ft)=LI
__ ""ol Factored Uplift (kips) Factored Download (kips) Factored Shear (kips) Width of Tower (ft) Ultimate Bearing Pressure Bearing <Ils Overturning <Ils Bearing Design Strength (ksf)
Water Table Below Grade (ft) Width of Mat (ft) Thickness of Mat (ft) Depth to Bottom of Slab (ft) Bolt Circle Diameter (in) Top of Concrete to Top of Bottom Threads (in) Diameter of
Pier (ft) HI. of Pier Above Ground (ft) HI. of Pier Below Ground (ft) Quantity of Bars in Mat Bar Diameter in Mat (in) Area of Bars in Mat (in') Spacing of Bars in Mat (in) Quantity
of Bars Pier Bar Diameter in Pier (in) Tie Bar Diameter in Pier (in) Spacing of Ties (in) Area of Bars in Pier (in') Spacing of Bars in Pier (in) fc (ksi) fy (ksi) Unit WI. of Soil (kcf)
Unit WI. of Concrete (kcf) Volume of Concrete (yd') ; . . , . ;. 1 : ... . ... 139.19 . 136.,72·· 1.2.53 ... 9 4.5 0.75 0.75 3.375 999 185 1.5 4 9 35;5 • . 2.5, 0.5 '" 2.5 20 : • 0.75
8.84 11.33 8 0,75 0:5 12 3.53 8.74 4 60 0.11 0.15 20.65 Max. Factored Net Bearing Pressure (ksf) I· .. ::'.1,\19'1' ·1 Minimum Mat Width (ft) Minimum Pier Diameter (ft) Equivalent Square
b (ft) Recommended Spacing (in) Minimum Pier A, (in') Recommended Spacing (in) p.A'I
MAT FOUNDATION DESIGN BY SABRE TOWERS & POLES (CONTINUED) Two-Way Shear: Average d (in) ~Vc (kips) ~Vc= $(2 + 4lPclfc'l2bod 4>Vc =~(a,dlbo +2)f, 1I2bod ~V, = 4>4f c 1I2bod Shear perimeter,
bo (in) Pc Stability: Resisting moment Overturning Design Strength (ft-k) One-Way Shear: <jNc(kips) Pier Design: Design Tensile Strength (kips) 4>V, (kips) 4>V,=4>2(1 +NJ(500Ag))f c
1I2bwd V, (kips) Maximum Spacing (in) Actual Hook Development (in) Anchor Bolt Pull-Out: 4>Pc=4>A(213)f c 112(2.8AslOPE+ 4AFLAT) Pier Rebar Development Length (in Flexure in Slab: ~Mn
(ft-kips) a (in) Steel Ratio P, Maximum Steel Ratio (. 75Pb) Minimum Steel Ratio Rebar Development in Pad (in) Condition Minimum Mat Width Maximum Soil Bearing Pressure Pier Area of
Steel Pier Shear Two-Way Shear Overturning Anchor Bolt PUll-Out Flexure Steel Ratio Length of Development in Pad Interaction Diagram Visual Check One-Way Shear Hook Development Minimum
Mat De th 14.25 639.0 649.6 426.0 139.02 1 1628.97 46.9 12.00 13.50 0.70 0.00279 0.85 0.0214 0.0018 1 is OK, 0 Fails 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Vu (kips) Factored Overturning Moment
(ft-k) Vu (kips) Tu (kips) Vu (kips) ... V, max = 4 f, 1I2bwd (kips) (Only if Shear Ties are Required) Req'd Hook Development Idh (in) ••• Ref. ACI 11.5.5 & 11.5.6.3 Pu (kips) Required
Length of Development (in) Mu (ft-kips) Required Development in Pad (in) ~ 136;7 ·1 1 11.195:5. F ).~(5.9ii 1 9.96 37.54 .1
) Federal Communications Commission Office of Engineering & Technology Questions and Answers about Biological Effects and Potential Hazards of Radiofrequency Electromagnetic Fields OET
BULLETIN 56 Fourth Edition August 1999
Questions and Answers about Biological Effects and Potential Hazards of Radiofrequency Electromagnetic Fields OET BULLETIN 56 Fourth Edition August 1999 Authors Robert F. Cleveland,
Jr. Jerry L. Ulcek Office of Engineering and Technology Federal Communications Commission Washington, D.C. 20554
INTRODUCTION Many consumer and industrial products and applications make use of some form of electromagnetic energy. One type of electromagnetic energy that is of increasing importance
worldwide is radio frequency (or "RF") energy, including radio waves and microwaves, which is used for providing telecommunications, broadcast and other services. In the United States
the Federal Communications Commission (FCC) authorizes or licenses most RF telecommunications services, facilities, and devices used by the public, industry and state and local governmental
organizations. Because of its regulatory responsibilities in this area the FCC often receives inquiries concerning whether there are potential safety hazards due to human exposure to
RF energy emitted by FCC-regulated transmitters. Heightened awareness of the expanding use of RF technology has led some people to speculate that "electromagnetic pollution" is causing
significant risks to human health from environmental RF electromagnetic fields. This document is designed to provide factual information and to answer some of the most commonly asked
questions related to this topic. l WHAT IS RADIOFREQUENCY ENERGY? Radio waves and microwaves are forms of electromagnetic energy that are collectively described by the term "radiofrequency"
or "RF." RF emissions and associated phenomena can be discussed in terms of "energy," "radiation" or "fields." Radiation is defined as the propagation of energy through space in the
form of waves or particles. Electromagnetic "radiation" can best be described as waves of electric and magnetic energy moving together (i.e., radiating) through space as illustrated
in Figure 1. These waves are generated by the movement of electrical charges such as in a conductive metal object or antenna. For example, the alternating movement of charge (i.e., the
"current") in an antenna used by a radio or television broadcast station or in a cellular base station antenna generates electromagnetic waves that radiate away from the "transmit" antenna
and are then intercepted by a "receive" antenna such as a rooftop TV antenna, car radio antenna or an antenna integrated into a hand-held device such as a cellular telephone. The tenn
"electromagnetic field" is used to indicate the presence of electromagnetic energy at a given location. The RF field can be described in terms of the electric andlor magnetic field strength
at that location.' Like any wave-related phenomenon, electromagnetic energy can be characterized by a wavelength and a frequency. The wavelength (A) is the distance covered by one complete
1 Exposure to low-frequency electromagnetic fields generated by electric power transmission has also been the subject of public concern. However, because the FCC does not have regulatory
authority with respect to power-line electromagnetic fields, this document only addresses questions related to RF exposure. Infannation about exposure due to electrical power transmission
can be obtained from several sources, including the following Internet World Wide Web site: http://www.niehs.nih.gov/emfrapid 2 The term "EMF" is often used to refer to electromagnetic
fields, in general. It can be used to refer to either power-line frequency fields, radiofrequency electromagnetic fields or both.
electromagnetic wave cycle, as shown in Figure 1. The frequency is the number of electromagnetic waves passing a given point in one second. For example, a typical radio wave transmitted
by an FM radio station has a wavelength of about three (3) meters and a frequency of about 100 million cycles (waves) per second or "100 MHz." One "hertz" (abbreviated "Hz") equals one
cycle per second. Therefore, in this case, about 100 million RF electromagnetic waves would be transmitted to a given point every second. Electric Field ~ FIGURE 1. Electromagnetic Wave
Magnetic Field V Direction of Propagation Electromagnetic waves travel through space at the speed of light, and the wavelength and frequency of an electromagnetic wave are inversely
related by a simple mathematical formula: frequency (f) times wavelength (A.) = the speed of light (c), or Ix A. = c. This simple equation can also be expressed as follows in terms of
either frequency or wavelength: f c 1: or 1 c f Since the speed of light in a given medium or vacuum does not change, highfrequency electromagnetic waves have short wavelengths and low-frequency
waves have long wavelengths. The electromagnetic "spectrum" (Figure 2) includes all the various forms of electromagnetic energy from extremely low frequency (ELF) energy, with very long
wavelengths, to X-rays and gamma rays, which have very high frequencies and correspondingly short wavelengths. In between these extremes are radio waves, microwaves, infrared radiation,
visible light, and ultraviolet radiation, in that order. The RF part of the electromagnetic spectrum is generally defined as that part of the spectrum where 2
) electromagnetic waves have frequencies in the range of about 3 kilohertz to 300 gigahertz. One kilohertz (kHz) equals one thousand hertz, one megahertz (MHz) equals one million hertz,
and one gigahertz (GHz) equals one billion hertz. Thus, when you tune your FM radio to 101.5, it means that your radio is receiving signals from a radio station emitting radio waves
at a frequency of 10l.5 million cycles (waves) per second, or 101.5 MHz. Frequency (Hertz) "'''''------NON -IONIZING ------<>~ I <l---IONIZING -----<>~ I 1-Radlofrequendes ---t> Power
Unes Radlo and Microwaves I infra-red II,Ultra-Violet X-rays Television Cellular Radio 6 •• & Gamma Rays I I !I I I I I! I I Energy (eV) I I I , I I I I I I I I I I I I I I I FIGURE
2_ The Electrolllaglletic SpectrulII HOW DO WE USE RADIOFREQUENCY ENERGY? Probably the most important use for RF energy is in providing telecommunications services to the public, industry
and govell1ment. Radio and television broadcasting, cellular telephones, personal communications services (peS), pagers, cordless telephones, business radio, radio communications for
police and fire departments, amateur radio, microwave point-to-point radio links and satellite communications are just a few of the many applications of RF energy for telecommunications.
Microwave ovens and radar are examples of non-communications uses of RF energy. Also important are uses of RF energy in industrial heating and sealing where electronic devices generate
RF radiation that rapidly heats the material being processed in the same way that a microwave oven cooks food . RF heaters and sealers have many uses in industry, 3
including molding plastic materials, gluing wood products, sealing items such as shoes and pocketbooks, and processing food products. There are a number of medical applications of RF
energy, including a technique called diathermy, that take advantage of the ability of RF energy to rapidly heat tissue below the body's surface. Tissue heating ("hyperthermia") can be
beneficial in the therapeutic treatment of injured tissue and cancerous tumors (see References 17 & 18). WHAT ARE MICROWAVES? Microwaves are a specific category of radio waves that can
be defined as radiofrequency radiation where frequencies range upward from several hundred megahertz (MHz) to several gigahertz (GHz). One of the most familiar and widespread uses of
microwave energy is found in household microwave ovens, which operate at a frequency of 2450 MHz (2.45 GHz). Microwaves are also widely used for telecommunications purposes such as for
cellular radio, personal communications services (peS), microwave point-to-point communication, transmission links between ground stations and orbiting satellites, and in certain broadcasting
operations such as studio-to-transmitter (STL) and electronic news gathering (ENG) radio links. Microwave radar systems provide information on air traffic and weather and are extensively
used in military and police applications. In the medical field microwave devices are used for a variety of therapeutic purposes including the selective heating of tumors as an adjunct
to chemotherapy treatment (microwave hyperthermia). Radiofrequency radiation, especially at microwave frequencies, efficiently transfers energy to water molecules. At high microwave
intensities the resulting energetic water molecules can generate heat in water-rich materials such as most foods. The operation of microwave ovens is based on this principle. This efficient
absorption of microwave energy via water molecules results in rapid heating throughout an object, thus allowing food to be cooked more quickly than in a conventional oven. WHAT IS NON-IONIZING
RADIATION? As explained earlier, electromagnetic radiation is defined as the propagation of energy through space in the form of waves or particles. Some electromagnetic phenomena can
be most easily described if the energy is considered as waves, while other phenomena are more readily explained by considering the energy as a flow of particles or "photons." This is
known as the "wave-particle" duality of electromagnetic energy. The energy associated with a photon, the elemental unit of an electromagnetic wave, depends on its frequency (or 4
wavelength). The higher the frequency of an electromagnetic wave (and the shorter its corresponding wavelength), the greater will be the energy of a photon associated with it. The energy
content of a photon is often expressed in terms of the unit "electron-volt" or "eV". Photons associated with X-rays and gamma rays (which have very high electromagnetic frequencies)
have a relatively large energy content. At the other end of the electromagnetic spectrum, photons associated with low-frequency waves (such as those at ELF frequencies) have many times
less energy. In between these extremes ultraviolet radiation, visible light, infrared radiation, and RF energy (including microwaves) exhibit intermediate photon energy content. For
comparison, the photon energies associated with high-energy X-rays are billions of times more energetic than the energy of a l-GHz microwave photon. The photon energies associated with
the various frequencies of the electromagnetic spectrum are shown in the lower scale of Figure 2. Ionization is a process by which electrons are stripped from atoms and molecules. This
process can produce molecular changes that can lead to damage in biological tissue, including effects on DNA, the genetic material. This process requires interaction with photons containing
high energy levels, such as those of X -rays and gamma rays. A single quantum event (absorption of an X-ray or gamma-ray photon) can cause ionization and subsequent biological damage
due to the high energy content of the photon, which would be in excess of 10 eV (considered to be the minimum photon energy capable of causing ionization). Therefore, X-rays and gamma
rays are examples of ionizing radiation. Ionizing radiation is also associated with the generation of nuclear energy, where it is often simply referred to as "radiation." The photon
energies of RF electromagnetic waves are not great enough to cause the ionization of atoms and molecules and RF energy is, therefore, characterized as non-ionizing radiation, along with
visible light, infrared radiation and other forms of electromagnetic radiation with relatively low frequencies. It is important that the terms "ionizing" and "non-ionizing" not be confused
when discussing biological effects of electromagnetic radiation or energy, since the mechanisms of interaction with the human body are quite different. HOW ARE RADIOFREQUENCY FIELDS
MEASURED? Because an RF electromagnetic field has both an electric and a magnetic component (electric field and magnetic field), it is often convenient to express the intensity of the
RF field in terms of units specific for each component. The unit "volts per meter" (Vim) is often used to measure the strength ("field strength") of the electric field, and the unit
"amperes per meter" (Aim) is often used to express the strength of the magnetic field. Another commonly used unit for characterizing an RF electromagnetic field is "power density." Power
density is most accurately used when the point of measurement is far enough 5
away from the RF emitter to be located in what is commonly referred to as the "far-field" zone of the radiation source, e.g., more than several wavelengths distance from a typical RF
source. In the far field, the electric and magnetic fields are related to each other in a known way, and it is only necessary to measure one of these quantities in order to determine
the other quantity or the power density. In closer proximity to an antenna, i.e., in the "near-field" zone, the physical relationships between the electric and magnetic components of
the field are usually complex. In this case, it is necessary to determine both the electric and magnetic field strengths to fully characterize the RF environment. (Note: In some cases
equipment used for making field measurements displays results in tenns of "far-field equivalent" power density, even though the measurement is being taken in the near field.) At frequencies
above about 300 MHz it is usually sufficient to measure only the electric field to characterize the RF environment if the measurement is not made too close to the RF emitter. Power density
is defined as power per unit area. For example, power density can be expressed in terms of milliwatts per square centimeter (mW/cm2) or microwatts per square centimeter (~W/cm2). One
mW equals 0.001 watt of power, and one ~W equals 0.000001 watt. With respect to frequencies in the microwave range and higher, power density is usually used to express intensity since
exposures that might occur would likely be in the farfield. More details about the physics of RF fields and their analysis and measurement can be found in References 2, 3, 8, 21, 33,
34 and 35. WHAT BIOLOGICAL EFFECTS CAN BE CAUSED BY RF ENERGY? A biological effect occurs when a change can be measured in a biological system after the introduction of some type of
stimuli. However, the observation of a biological effect, in and of itself, does not necessarily suggest the existence of a biological hazard. A biological effect only becomes a safety
hazard when it "causes detectable impainnent of the health of the individual or of his or her offspring" (Reference 25). There are many published reports in the scientific literature
concerning possible biological effects resulting from animal or human exposure to RF energy. The following discussion only provides highlights of current knowledge, and it is not meant
to be a complete review of the scientific literature in this complex field. A number of references are listed at the end of this document that provide further information and details
concerning this topic and some recent research reports that have been published (References 1,3,6, 7,9, 14, 15-19,21,25,26,28-31,34,36,39-41,47,49 and 53). Biological effects that result
from heating of tissue by RF energy are often referred to as "thermal" effects. It has been known for many years that exposure to high levels of RF radiation can be harmful due to the
ability of RF energy to heat biological tissue rapidly. This is the principle by which microwave ovens cook food, and exposure to very high RF power densities, i.e., on the order of
100 mW/cm' or more, can clearly result in heating of 6
biological tissue and an increase in body temperature. Tissue damage in humans could occur during exposure to high RF levels because of the body's inability to cope with or dissipate
the excessive heat that could be generated. Under certain conditions, exposure to RF energy at power density levels of 1-10 mW/cm' and above can result in measurable heating of biological
tissue (but not necessarily tissue damage). The extent of this heating would depend on several factors including radiation frequency; size, shape, and orientation of the exposed object;
duration of exposure; environmental conditions; and efficiency of heat dissipation. Two areas of the body, the eyes and the testes, are known to be particularly vulnerable to heating
by RF energy because of the relative lack of available blood flow to dissipate the excessive heat load (blood circulation is one of the body's major mechanisms for coping with excessive
heat). Laboratory experiments have shown that short-term exposure (e.g., 30 minutes to one hour) to very high levels of RF radiation (100-200 mW/cm') can cause cataracts in rabbits.
Temporary sterility, caused by such effects as changes in sperm count and in sperm motility, is possible after exposure of the testes to high-level RF radiation (or to other forms of
energy that produce comparable increases in temperature). Studies have shown that environmental levels of RF energy routinely encountered by the general public are far below levels necessary
to produce significant heating and increased body temperature (References 32, 37, 45, 46, 48 and 54). However, there may be situations, particularly workplace environments near high-powered
RF sources, where recommended limits for safe exposure of human beings to RF energy could be exceeded. In such cases, restrictive measures or actions may be necessary to ensure the safe
use of RF energy. In addition to intensity, the frequency of an RF electromagnetic wave can be important in determining how much energy is absorbed and, therefore, the potential for
harm. The quantity used to characterize this absorption is called the "specific absorption rate" or "SAR," and it is usually expressed in units of watts per kilogram (W/kg) or milliwatts
per gram (mW/g). In the far-field of a source of RF energy (e.g., several wavelengths distance from the source) whole-body absorption of RF energy by a standing human adult has been
shown to occur at a maximum rate when the frequency of the RF radiation is between about 80 and 100 MHz, depending on the size, shape and height of the individual. In other words, the
SAR is at a maximum under these conditions. Because of this "resonance" phenomenon, RF safety standards have taken account of the frequency dependence of whole-body human absorption,
and the most restrictive limits on exposure are found in this frequency range (the very high frequency or "VHF" frequency range). Although not commonly observed, a microwave "hearing"
effect has been shown to occur under certain very specific conditions of frequency, signal modulation, and intensity where animals and humans may perceive an RF signal as a buzzing or
clicking sound. Although a number of theories have been advanced to explain this effect, the most widely-accepted hypothesis is that the microwave signal produces thermoelastic pressure
within the head that is perceived as sound by the auditory apparatus within the ear. This effect is not recognized as a health hazard, and the conditions under which it might occur 7
would rarely be encountered by members of the public. Therefore, this phenomenon should be of little concern to the general population. Furthermore, there is no evidence that it could
be caused by telecommunications applications such as wireless or broadcast transmissions. At relatively low levels of exposure to RF radiation, i.e., field intensities lower than those
that would produce significant and measurable heating, the evidence for production of harmful biological effects is ambiguous and unproven. Such effects have sometimes been referred
to as "non-thennal" effects. Several years ago publications began appearing in the scientific literature, largely overseas, reporting the observation of a wide range of low-level biological
effects. However, in many of these cases further experimental research was unable to reproduce these effects. Furthennore, there has been no detennination that such effects might indicate
a human health hazard, particularly with regard to long-term exposure. More recently, other scientific laboratories in North America, Europe and elsewhere have reported certain biological
effects after exposure of animals ("in vivo") and animal tissue ("in vitro") to relatively low levels of RF radiation. These reported effects have included certain changes in the immune
system, neurological effects, behavioral effects, evidence for a link between microwave exposure and the action of certain drugs and compounds, a "calcium efflux" effect in brain tissue
(exposed under very specific conditions), and effects on DNA. Some studies have also examined the possibility of a link between RF and microwave exposure and cancer. Results to date
have been inconclusive. While some experimental data have suggested a possible link between exposure and tumor formation in animals exposed under certain specific conditions, the results
have not been independently replicated. In fact, other studies have failed to find evidence for a causal link to cancer or any related condition. Further research is underway in several
laboratories to help resolve this question. In general, while the possibility of "non-thennal" biological effects may exist, whether or not such effects might indicate a human health
hazard is not presently known. Further research is needed to determine the generality of such effects and their possible relevance, if any, to human health. In the meantime, standards-setting
organizations and government agencies continue to monitor the latest experimental findings to confirm their validity and detennine whether alterations in safety limits are needed in
order to protect human health. WHAT RESEARCH IS BEING DONE ON RF BIOLOGICAL EFFECTS? For many years research into possible biological effects of RF energy has been carried out in government,
academic and industrial laboratories all over the world, and such research is continuing. Past research has resulted in a very large number of scientific publications on this topic,
some of which are listed in the reference section of this document. For many years the U.S. Government has sponsored research into the biological effects of RF energy. The majority of
this work has been funded by the Department of Defense, due, in part, to the 8
extensive military interest in using RF equipment such as radar and other relatively highpowered radio transmitters for routine military operations. In addition, some U.S. civilian federal
agencies responsible for health and safety, such as the Environmental Protection Agency (EPA) and the U.S. Food and Drug Administration (FDA), have sponsored and conducted research in
this area in the past, although relatively little civilian-sector RF research is currently being funded by the U.S. Government. At the present time, much of the non-military research
on biological effects of RF energy in the U.S. is being funded by industry organizations such as Motorola, Inc. In general, relatively more research is being carried out overseas, particularly
in Europe. In 1996, the World Health Organization (WHO) established a program (the International EMF Project) designed to review the scientific literature concerning biological effects
of electromagnetic fields, identifY gaps in knowledge about such effects, recommend research needs, and work towards international resolution of health concerns over the use of RF technology.
(see Reference 40) The WHO and other organizations maintain Internet Web sites that contain additional information about their programs and about RF biological effects and research (see
list of Web sites in Table 3 of this bulletin). The FDA, the EPA and other federal agencies responsible for public health and safety are working with the WHO and other organizations
to monitor developments and identify research needs related to RF biological effects. For example, in 1995 the EPA published the results of a conference it sponsored to assess the current
state of knowledge of RF biological effects and to address future research needs in this area (Reference 53). WHAT LEVELS ARE SAFE FOR EXPOSURE TO RF ENERGY? Development of Exposure
Guidelines Exposure standards and guidelines have been developed by various organizations and countries over the past several decades. In North America and most of Europe exposure standards
and guidelines have generally been based on exposure levels where effects considered harmful to humans occur. Safety factors are then incorporated to arrive at specific levels of exposure
to provide sufficient protection for various segments of the population. Not all standards and guidelines throughout the world have recommended the same limits for exposure. For example,
some published exposure limits in Russia and some eastern European countries have been generally more restrictive than existing or proposed recommendations for exposure developed in
North America and other parts of Europe. This discrepancy may be due, at least in part, to the possibility that these standards were based on exposure levels where it was believed no
biological effects of any type would occur. This philosophy is inconsistent with the approach taken by most other standards-setting bodies which base limits on levels where recognized
hazards may occur and then incorporate appropriate safety margins to ensure adequate protection. 9
In the United States, although the Federal Government has never itself developed RF exposure standards, the FCC has adopted and used recognized safety guidelines for evaluating RF environmental
exposure since 1985. Federal health and safety agencies, such as the Environmental Protection Agency (EPA), the Food and Drug Administration (FDA), the National Institute for Occupational
Safety and Health (NIOSH) and the Occupational Safety and Health Administration (OSHA) have also been actively involved in monitoring and investigating issues related to RF exposure.
For example, the FDA has issued guidelines for safe RF emission levels from microwave ovens, and it continues to monitor exposure issues related to the use of certain RF devices such
as cellular telephones. NIOSH conducts investigations and health hazard assessments related to occupational RF exposure. In 1971, a federal RF radiation protection guide for workers
was issued by OSHA based on the 1966 American National Standards Institute (ANSI) RF exposure standard. However, the OSHA regulation was later ruled to be advisory only and not enforceable.
Presently, OSHA enforcement actions related to RF exposure of workers are undertaken using OSHA's "general duty clause," which relies on the use of widely-supported voluntary "consensus"
standards such as those discussed below.3 U.S. federal, state and local governmental agencies and other organizations have generally relied on RF exposure standards developed by expert
non-government organizations such as ANSI, the Institute of Electrical and Electronics Engineers (IEEE) and the National Council on Radiation Protection and Measurements (NCRP).4 For
example, in 1966, 1974, and 1982, ANSI issued protection guides for RF exposure developed by committees of experts. These earlier ANSI standards recommended limits for exposure of the
public that were the same as those recommended for exposure of workers. In 1986, the NCRP issued exposure criteria for the workplace that were the same as the 1982 ANSI recommended levels,
but the NCRP also recommended more restrictive limits for exposure of the general public. Therefore, the NCRP exposure criteria included two tiers of recommended limits, one for the
general population and another for occupational exposure. In 1987, the ANSI committee on RF exposure standards (Standards Coordinating Committee 28) became a committee of the IEEE, and,
in 1991, revised its earlier standard and issued its own two-tiered standard that had been developed over a period of several years. For infonnation about OSHA RF-related activities
and RF protection programs for workers, see the OSHA Internet Web site (case sensitive): www.osha-s1c.gov/SLTC/(select subject: "radiofrequency radiation"). ANSI is a non-profit, privately
funded, membership organization that coordinates development of voluntary national standards. The IEEE is a non-profit technical and professional engineering society. The NCRP is a nonprofit
corporation chartered by the U.S. Congress to develop information and recommendations concerning radiation protection. Several government agencies, including the FCC, and non-government
organizations have established relationships with NCRP as "Collaborating Organizations," 10
The ANSI/IEEE standards have been widely used and cited and have served as the basis for similar standards in the United States and in other countries. Both the NCRP and ANSI/IEEE guidelines
were developed by scientists and engineers with a great deal of experience and knowledge in the area of RF biological effects and related issues. These individuals spent a considerable
amount of time evaluating published scientific studies relevant to establishing safe levels for human exposure to RF energy. In addition to NCRP and ANSI/IEEE, other organizations and
countries have issued exposure guidelines. For example, several European countries are basing guidelines on exposure criteria developed by the International Committee on Nonionizing
Radiation Protection (ICNIRP, Reference 25). The ICNIRP guidelines are also derived from an SAR threshold of 4 W/kg (for adverse effects) and are similar to the 1992 ANSI/IEEE and NCRP
recommendations with certain exceptions. For example, ICNIRP recommends somewhat different exposure levels in the lower and upper frequency ranges and for localized exposure due to such
devices as hand-held cellular telephones. Many, but not all, countries have based exposure recommendations on the same general concepts and thresholds as those used by the NCRP, ANSI/IEEE
and ICNIRP. Because of differences in international standards, the World Health Organization (WHO), as part of its EMF Project (discussed earlier), has initiated a program to try and
develop an international framework for RF safety standards. FCC Exposure Guidelines In 1985, the FCC adopted the 1982 ANSI guidelines for purposes of evaluating exposure due to RF transmitters
licensed and authorized by the FCC. This decision was in response to provisions of the National Environmental Policy Act of 1969 requiring all Federal Government agencies to evaluate
the impact of their actions on the "quality of the human environment.'" In 1992, ANSI adopted the 1991 IEEE standard as an American National Standard (a revision of its 1982 standard)
and designated it ANSI/IEEE C95.l-1992.6 In 1993, the FCC proposed to update its rules and adopt the new ANSI/IEEE guidelines. After a lengthy period to allow for the filing of comments
and for deliberation the FCC decided, in 1996, to adopt a modified version of its original proposal.' The FCC's The National Environmental Policy Act of 1969, 42 USC Section 4321, e/seq.
6 ANSI/IEEE C95.1-1992 (originally issued as IEEE C95.1-1991), "IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300
GHz," (Reference 3). See Report and Order and Second Memorandum Opinion and Order and No/ice of Proposed Rulemaking, ET Docket 93-62, (References 55 and 56). In 1997, the FCC released
a technical bulletin entitled, "Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields," OET Bulletin 65 (Reference 57) that contains detailed
information on methods for compliance with FCC guidelines. These documents can be accessed at the FCC's Web site: http://www.fcc.gov/oetirfsafety. II
action also fulfilled requirements of the Telecommunications Act of 1996 for adopting new RF exposure guidelines.8 The FCC considered a large number of comments submitted by industry,
government agencies and the public. In particular, the FCC considered comments submitted by the EPA, FDA, NIOSH and OSHA, which have primary responsibility for health and safety in the
Federal Government. The guidelines the FCC adopted were based on the recommendations of those agencies, and they have sent letters to the FCC supporting its decision and endorsing the
FCC's guidelines as protective of public health. In its 1996 Order, the FCC noted that research and analysis relating to RF safety and health is ongoing and changes in recommended exposure
limits may occur in the future as knowledge increases in this field. In that regard, the FCC will continue to cooperate with industry and with expert agencies and organizations with
responsibilities for health and safety in order to ensure that the FCC's guidelines continue to be appropriate and scientifically valid. The FCC's guidelines are based on recommended
exposure criteria issued by the NCRP and ANSI/IEEE. The NCRP exposure guidelines are similar to the ANSI/IEEE 1992 guidelines except for differences in recommended exposure levels at
the lower frequencies and higher frequencies of the RF spectrum. Both ANSI/IEEE and NCRP recommend two different tiers of exposure limits. The NCRP designates one tier for occupational
exposure and the other for exposure of the general population while ANSI/IEEE designates exposure tiers in terms of "environments," one for "controlled" environments and the other for
"uncontrolled" environments. Over a broad range of frequencies, NCRP exposure limits for the public are generally one-fifth those for workers in terms of power density.' The NCRP and
ANSI/IEEE exposure criteria identify the same threshold level at which harmful biological effects may occur, and the values for Maximum Permissible Exposure (MPE) recommended for electric
and magnetic field strength and power density in 8 The Telecommunications Act of 1996, enacted on February 8, 1996, required that: "Within 180 days after the enactment of this Act, the
Commission shall complete action in ET Docket 93-62 to prescribe and make effective rules regarding the environmental effects of radio frequency emissions. II See Section 704(b) of the
Telecommunications Act of 1996, Pub. L. No. 104-104, 110 Stat. 56 (1996). The FCC adopted limits for field strength and power density that are based on Sections 17.4.1 and 17.4.2, and
the time-averaging provisions of Sections 17.4.1.1 and 17.4.3, of "Biological Effects and Exposure Criteria for Radiofrequency Electromagnetic Fields," NCRP Report No. 86, for frequencies
between 300 kHz and 100 GHz (Reference 34). With the exception of limits on exposure to power density above 1500 MHz, and limits for exposure to lower frequency magnetic fields, these
MPE limits are also based on the guidelines developed by the IEEE and adopted by ANSI. See Section 4.1 of ANSI/IEEE C95.1-1992, "Safety Levels with Respect to Human Exposure to Radio
Frequency Electromagnetic Fields, 3 kHz to 300 GHz" (Reference 3). 12
both documents are based on this threshold level. lO In addition, both the ANSI/IEEE and NCRP guidelines are frequency dependent, based on findings (discussed earlier) that wholebody
human absorption of RF energy varies with the frequency of the RF signal. The most restrictive limits on exposure are in the frequency range of 30-300 MHz where the human body absorbs
RF energy most efficiently when exposed in the far field of an RF transmitting source. Although the ANSI/IEEE and NCRP guidelines differ at higher and lower frequencies, at frequencies
used by the majority of FCC licensees the MPE limits are essentially the same regardless of whether ANSI/IEEE or NCRP guidelines are used. Most radiofrequency safety limits are defined
in terms of the electric and magnetic field strengths as well as in terms of power density. For lower frequencies, limits are more meaningfully expressed in terms of electric and magnetic
field strength values, and the indicated power densities are actually "far-field equivalent" power density values. The latter are listed for comparison purposes and because some instrumentation
used for measuring RF fields is calibrated in tenns of far-field or plane-wave equivalent power density. At higher frequencies, and when one is actually in the "far field" of a radiation
source, it is usually only necessary to evaluate power density. In the far field of an RF transmitter power density and field strength are related by standard mathematical equations."
The exposure limits adopted by the FCC in 1996 expressed in terms of electric and magnetic field strength and power density for transmitters operating at frequencies from 300 kHz to
100 GHz are shown in Table 1. The FCC also adopted limits for localized ("partial body") absorption in terms of SAR, shown in Table 2, that apply to certain portable transmitting devices
such as hand-held cellular telephones." 10 These exposure limits are based on criteria quantified in tenns of specific absorption rate (SAR). SAR is a measure of the rate at which the
body absorbs RF energy. Both the ANSI/IEEE and NCRP exposure criteria are based on a determination that potentially harmful biological effects can occur at an SAR level of 4 W/kg as
averaged over the whole-body. Appropriate safety factors have been incorporated to arrive at limits for both whole-body exposure (0.4 W/kg for "controlled" or "occupational II exposure
and 0.08 W/kg for "uncontrolled" or "general population" exposure, respectively) and for partial-body (localized SAR), such as might occur in the head of the user of a hand-held cellular
telephone. The new MPE limits are more conservative in some cases than the limits specified by ANSI in 1982. However, these more conservative limits do not arise from a fundamental change
in the SAR threshold for harm, but from a precautionary desire to add an additional margin of safety for exposure of the public or exposure in "uncontrolled' environments. II See OET
Bulletin 65 (Reference 57) for details. 12 These guidelines are based on those recommended by ANSIIIEEE and NCRP. See Sections 4.2.1 and 4.2.2 of ANSIIIEEE C95.1-1992 and Section 17.4.5
of NCRP Report No. 86. For purposes of evaluation, the FCC has designated these devices as either "portable" or "mobile" depending on how they are to be used. Portable devices are normally
those used within 20 centimeters of the body and must be evaluated with respect to SAR limits. Mobile devices are nonnally used 20 centimeters or more away from the body and can be evaluated
in temlS of either SAR or field intensity. Detailed infonnation on FCC requirements for evaluating portable and mobile devices can be found in OET Bulletin 65 and in the FCC's Rules
and Regulations, 47 CFR 2.1091 and 2.1093. 13
Time Averaging of Exposure The NCRP and ANSI/IEEE exposure criteria and most other standards specify "time-averaged" MPE limits. This means that it is permissible to exceed the recommended
limits for short periods of time as long as the average exposure (over the appropriate period specified) does not exceed the limit. For example, Table 1 shows that for a frequency of
100 MHz the recommended power density limit is 1 mW/cm' with an averaging time of six minutes (any six-minute period) for occupational/controlled exposure. The time-averaging concept
can be illustrated as follows for exposure in a workplace environment. The sum of the product (or products) of the actual exposure level(s) multiplied by the actual time(s) of exposure
must not be greater than the allowed (average) exposure limit times the specified averaging time. Therefore, for 100 MHz, exposure at 2 mW/cm2 would be permitted for three minutes in
any six-minute period as long as during the remaining three minutes of the six-minute period the exposure was at or near "zero" level of exposure. Therefore, in this example: (2 mW/cm2)
X (3 min.) + (0 mW/cm2) X (3 min.) = (1 mW/cm2) X (6 min.) Of course, other combinations of power density and time are possible. It is very important to remember that time averaging
of exposure is only necessary or relevant for situations where temporary exposures might occur that are in excess of the absolute limits for power density or field strength. These situations
usually only occur in workplace environments where exposure can be monitored and controlled. For general population/uncontrolled exposures, say in a residential neighborhood, it is seldom
possible to have sufficient information or control regarding how long people are exposed, and averaging of exposure over the designated time period (30 minutes) is normally not appropriate.
For such public exposure situations, the MPE limits normally apply for continuous exposure. In other words, as long as the absolute limits are not exceeded, indefinite exposure is allowed.
Induced and Contact Currents In addition to limits on field strength, power density and SAR, some standards for RF exposure have incorporated limits for currents induced in the human
body by RF fields. For example, the 1992 ANSIIIEEE standard (Reference 3), includes specific restrictions that apply to "induced" and "contact" currents (the latter, which applies to
"grasping" contact, is more related to shock and bum hazards). The limits on RF currents are based on experimental data showing that excessive SAR levels can be created in the body due
to the presence of these currents. In its 1996 Order adopting new RF exposure guidelines the FCC declined to adopt limits on induced and contact currents due primarily to the difficulty
of reliably determining compliance, either by prediction methods or by direct measurement. However, the FCC may reconsider this decision in the future because of the development of new
instrumentation and analytical techniques that may be more reliable indicators of exposure. 14
Table 1. FCC Limits for Maximum Permissible Exposure (MPE) (A) Limits for Occupational/Controlled Exposnre Frequency Electric Field Magnetic Field Power Density Averaging Time Range
Strength (E) Strength (H) (S) 1 E 12, 1 H 12 or S (MHz) (V/m) (A/m) (mW/cm') (minutes) 0.3-3.0 614 1.63 (100)* 6 3.0-30 I 842/f 4.89/f (900/f2)* 6 30-300 61.4 0.163 1.0 6 300-1500 f/300
6 1500-100,000 5 6 (8) Limits for General Population/Uncontrolled Exposure Frequency Electric Field Magnetic Field Power Density Averaging Time Range Strength (E) Strength (H) (S) 1
E 12, 1 H I' or S (MHz) (Vim) (A/m) (mW/cm') (minutes) 0.3-1.34 614 1.63 (100)* 30 1.34-30 824/f 2.19/f (l801f')* 30 30-300 27.5 0.073 0.2 30 300-1500 f/1500 30 1500-100,000 1.0 30 f
= frequency in MHz *Plane-wave equivalent power density NOTE 1: Occupational/controlled limits apply in situations in which persons are exposed as a consequence of their employment provided
those persons are fully aware of the potential for exposure and can exercise control over their exposure. Limits for occupational/controlled exposure also apply in situations when an
individual is transient through a location where occupational/controlled limits apply provided he or she is made aware of the potential for exposure. NOTE 2: General population/uncontrolled
exposures apply in situations in which the general public may be exposed, or in which persons that are exposed as a consequence of their employment may not be fully aware of the potential
for exposure or can not exercise control over their exposure. 15
Table 2. FCC Limits for Localized (Partial-body) Exposure Specific Absorption Rate (SAR) Occupational/Controlled Exposure General Uncontrolled/Exposure (100 kHz -6 GHz) (100 kHz -6 GHz)
< 0.4 W/kg whole-body < 0.08 W/kg whole-body ::::8 W/kg partial-body :::: 1.6 W /kg partial-body WHY HAS THE FCC ADOPTED GUIDELINES FOR RF EXPOSURE? The FCC authorizes and licenses devices,
transmitters and facilities that generate RF and microwave radiation. It has jurisdiction over all transmitting services in the U.S. except those specifically operated by the Federal
Government. However, the FCC's primary jurisdiction does not lie in the health and safety area, and it must rely on other agencies and organizations for guidance in these matters. Under
the National Environmental Policy Act of 1969 (NEPA), the FCC has certain responsibilities to consider whether its actions will "significantly affect the quality of the human environment."
Therefore, FCC approval and licensing of transmitters and facilities must be evaluated for significant impact on the environment. Human exposure to RF radiation emitted by FCC-regulated
transmitters is one of several factors that must be considered in such environmental evaluations. Major RF transmitting facilities under the jurisdiction of the FCC, such as radio and
television broadcast stations, satellite-earth stations, experimental radio stations and certain cellular, PCS and paging facilities are required to undergo routine evaluation for RF
compliance whenever an application is submitted to the FCC for construction or modification of a transmitting facility or renewal of a license. Failure to comply with the FCC's RF exposure
guidelines could lead to the preparation of a formal Environmental Assessment, possible Environmental Impact Statement and eventual rejection of an application. Technical 16
guidelines for evaluating compliance with the FCC RF safety requirements can be found in the FCC's OET Bulletin 65 (Reference 57). Low-powered, intermittent, or inaccessible RF transmitters
and facilities are normally "categorically excluded" from the requirement for routine evaluation for RF exposure. These exclusions are based on calculations and measurement data indicating
that such transmitting stations or devices are unlikely to cause exposures in excess of the guidelines under normal conditions of use.l3 The FCC's policies on RF exposure and categorical
exclusion can be found in Section 1.1307(b) of the FCC's Rules and Regulations. 14 It should be emphasized, however, that these exclusions are not exclusions from compliance, but, rather,
only exclusions from routine evaluation. Furthermore, transmitters or facilities that are otherwise categorically excluded from evaluation may be required, on a case-by-case basis, to
demonstrate compliance when evidence of potential non-compliance of the transmitter or facility is brought to the Commission's attention [see 47 CFR §1.l307(c) and (d)]. The FCC's policies
with respect to environmental RF fields are designed to ensure that FCC-regulated transmitters do not expose the public or workers to levels of RF radiation that are considered by expert
organizations to be potentially harmful. Therefore, if a transmitter and its associated antenna are regulated by the FCC, they must comply with provisions of the FCC's rules regarding
human exposure to RF radiation. In its 1997 Order, the FCC adopted a provision that all transmitters regulated by the FCC, regardless of whether they are excluded from routine evaluation,
are expected to be in compliance with the new guidelines on RF exposure by September I, 2000 (Reference 56). In the United States some local and state jurisdictions have also enacted
rules and regulations pertaining to human exposure to RF energy. However, the Telecommunications Act of 1996 contained provisions relating to federal jurisdiction to regulate human exposure
to RF emissions from certain transmitting devices.. In particular, Section 704 of the Act states that, "No State or local government or instrumentality thereof may regulate the placement,
construction, and modification of personal wireless service facilities on the basis of the environmental effects of radio frequency emissions to the extent that such facilities comply
with the Commission's regulations concerning such emissions." Further information on FCC policy with respect to facilities siting is available in a factsheet from the FCC's Wireless
Telecommunications Bureau." !3 The Council on Environmental Quality, which has oversight responsibility with regard to NEPA, pennits federal agencies to categorically exclude certain
actions from routine environmental processing when the potential for individual or cumulative environmental impact is judged to be negligible (40 CFR §§ 1507, 1508.4 and "Regulations
for Implementing the Procedural Provisions ofNEPA, 43 Fed, Reg, 55,978, 1978). 14 47 Code of Federal Regulations 1.1307(b). 15 "fact Sheet 2", September 17, 1997, entitled, IINalional
Wireless Facilities Siting Policies," from the FCC's Wireless Telecommunications Bureau. This factsheet can be viewed and downloaded from the bureau's Internet World Wide Web Site: http://www.fcc,gov
/wtb/, 17
ARE EMISSIONS FROM RADIO AND TELEVISION ANTENNAS SAFE? Radio and television broadcast stations transmit their signals via RF electromagnetic waves. There are currently approximately
14,000 radio and TV stations on the air in the United States. Broadcast stations transmit at various RF frequencies, depending on the channel, ranging from about 550 kHz for AM radio
up to about 800 MHz for some UHF television stations. Frequencies for FM radio and VHF television lie in between these two extremes. Operating powers ("effective radiated power") can
be as little as a few hundred watts for some radio stations or up to millions of watts for certain television stations. Some of these signals can be a significant source of RF energy
in the local environment, and the FCC requires that broadcast stations submit evidence of compliance with FCC RF guidelines. The amount of RF energy to which the public or workers might
be exposed as a result of broadcast antennas depends on several factors, including the type of station, design characteristics of the antenna being used, power transmitted to the antenna,
height of the antenna and distance from the antenna. Since energy at some frequencies is absorbed by the human body more readily than energy at other frequencies, the frequency of the
transmitted signal as well as its intensity is important. Calculations can be performed to predict what field intensity levels would exist at various distances from an antenna. Public
access to broadcasting antennas is normally restricted so that individuals cannot be exposed to high-level fields that might exist near antennas. Measurements made by the FCC, EPA and
others have shown that ambient RF radiation levels in inhabited areas near broadcasting facilities are typically well below the exposure levels recommended by current standards and guidelines
(References 32, 46, 48, 51, 52). There have been a few situations around the country where RF levels in publicly accessible areas have been found to be higher than those recommended
by applicable safety standards (e.g., see Reference 50). But, in spite of the relatively high operating powers of many stations, such cases are unusual, and members of the general public
are unlikely to be exposed to RF levels from broadcast towers that exceed FCC limits. Wherever such situations have arisen corrective measures have been undertaken to ensure that areas
promptly come into compliance with the applicable guidelines. In cases where exposure levels might pose a problem, there are various steps a broadcast station can take to ensure compliance
with safety standards. For example, high-intensity areas could be posted and access to them could be restricted by fencing or other appropriate means. In some cases more drastic measures
might have to be considered, such as re-designing an antenna, reducing power, or station relocation. Antenna maintenance workers are occasionally required to climb antenna structures
for such purposes as painting, repairs, or beacon replacement. Both the EPA and OSHA have reported that in these cases it is possible for a worker to be exposed to high levels of RF
energy if work is perfonned on an active tower or in areas immediately surrounding a 18
radiating antenna (e.g., see Reference 42, 43, 45, and 51). Therefore, precautions should be taken to ensure that maintenance personnel are not exposed to unsafe RF fields. Such precautions
could include temporarily lowering power levels while work is being performed, having work performed only when the station is not broadcasting, using auxiliary antennas while work is
performed on the main antenna, and establishing work procedures that would specify the minimum distance that a worker should maintain from an energized antenna. HOW SAFE ARE MICROWAVE
AND SATELLITE ANTENNAS? Point-to-Point Microwave Antennas Point-to-point microwave antennas transmit and receive microwave signals across relatively short distances (from a few tenths
of a mile to 30 miles or more). These antennas are usually rectangular or circular in shape and are normally found mounted on a supporting tower, on rooftops, sides of buildings or on
similar structures that provide clear and unobstructed line-of-sight paths between both ends of a transmission path or link. These antennas have a variety of uses such as transmitting
voice and data messages and serving as links between broadcast or cable-TV studios and transmitting antennas. The RF signals from these antennas travel in a directed beam from a transmitting
antenna to a receiving antenna, and dispersion of microwave energy outside of the relatively narrow beam is minimal or insignificant. In addition, these antennas transmit using very
low power levels, usually on the order of a few watts or less. Measurements have shown that ground-level power densities due to microwave directional antennas are normally a thousand
times or more below recommended safety limits. (e.g., see Reference 38) Moreover, as an added margin of safety, microwave tower sites are normally inaccessible to the general public.
Significant exposures from these antennas could only occur in the unlikely event that an individual were to stand directly in front of and very close to an antenna for a period of time.
Satellite-Earth Stations Ground-based antennas used for satellite-earth communications typically are parabolic "dish" antennas, some as large as 10 to 30 meters in diameter, that are
used to transmit ("uplinks") or receive ("downlinks") microwave signals to or from satellites in orbit around the earth. The satellites receive the signals beamed up to them and, in
tum, retransmit the signals back down to an earthbound receiving station. These signals allow delivery of a variety of communications services, including long distance telephone service.
Some satellite-earth station antennas are used only to receive RF signals (i.e., just like a rooftop television antenna used at a residence), and, since they do not transmit, RF exposure
is not an issue. 19
Since satellite-earth station antennas are directed toward satellites above the earth, transmitted beams point skyward at various angles of inclination, depending on the particular satellite
being used. Because of the longer distances involved, power levels used to transmit these signals are relatively large when compared, for example, to those used by the microwave point-to-point
antennas discussed above. However, as with microwave antennas, the beams used for transmitting earth-to-satellite signals are concentrated and highly directional, similar to the beam
from a flashlight. In addition, public access would nonnally be restricted at station sites where exposure levels could approach or exceed safe limits. Although many satellite-earth
stations are "fixed" sites, portable uplink antennas are also used, e.g., for electronic news gathering. These antennas can be deployed in various locations. Therefore, precautions may
be necessary, such as temporarily restricting access in the vicinity of the antenna, to avoid exposure to the main transmitted beam. In general, however, it is unlikely that a transmitting
earth station antenna would routinely expose members of the public to potentially harmful levels of microwaves. ARE CELLULAR AND PCS TOWERS AND ANTENNAS SAFE? WHAT ABOUT CAR PHONES AND
HAND-HELD PHONES? Base Stations Cellular radio systems use frequencies between 800 and 900 megahertz (MHz). Transmitters in the Personal Communications Service (PCS) use frequencies
in the range of 1850-1990 MHz. The antennas for cellular and PCS transmissions are typically located on towers, water tanks or other elevated structures including rooftops and the sides
of buildings. The combination of antennas and associated electronic equipment is referred to as a cellular or PCS "base station" or "cell site." Typical heights for free-standing base
station towers or structures are 50-200 feet. A cellular base station may utilize several "omni-directional" antennas that look like poles, I 0 to IS feet in length, although these types
of antennas are becoming less common in urban areas. In urban and suburban areas, cellular and PCS service providers now more commonly use "sector" antennas for their base stations.
These antennas are rectangular panels, e.g., about I by 4 feet in dimension, typically mounted on a rooftop or other structure, but they are also mounted on towers or poles. The antennas
are usually arranged in three groups of three each. One antenna in each group is used to transmit signals to mobile units (car phones or hand-held phones), and the other two antennas
in each group are used to receive signals from mobile units. The FCC authorizes cellular and PCS carriers in various service areas around the country. At a cell site, the total RF power
that could be transmitted from each transmitting antenna at a cell site depends on the number of radio channels (transmitters) that have been 20
authorized and the power of each transmitter. Typically, for a cellular base station, a maximum of 21 channels per sector (depending on the system) could be used. Thus, for a typical
cell site utilizing sector antennas, each of the three transmitting antennas could be connected to up to 21 transmitters for a total of 63 transmitters per site. When omnidirectional
antennas are used, up to 96 transmitters could be implemented at a cell site, but this would be unusual. While a typical base station could have as many as 63 transmitters, not all of
the transmitters would be expected to operate simultaneously thus reducing overall emission levels. For the case of PCS base stations, fewer transmitters are normally required due to
the relatively greater number of base stations. Although the FCC permits an effective radiated power (ERP) of up to 500 watts per channel (depending on the tower height), the majority
of cellular base stations in urban and suburban areas operate at an ERP of 100 watts per channel or less. An ERP of 100 watts corresponds to an actual radiated power of about 5-10 watts,
depending on the type of antenna used (ERP is not equivalent to the power that is radiated but, rather, is a quantity that takes into consideration transmitter power and antenna directivity).
As the capacity of a system is expanded by dividing cells, i.e., adding additional base stations, lower ERPs are normally used. In urban areas, an ERP of 10 watts per channel (corresponding
to a radiated power of 0.5 -1 watt) or less is commonly used. For PCS base stations, even lower radiated power levels are normally used. The signal from a cellular or PCS base station
antenna is essentially directed toward the horizon in a relatively narrow pattern in the vertical plane. The radiation pattern for an omni-directional antenna might be compared to a
thin doughnut or pancake centered around the antenna while the pattern for a sector antenna is fan-shaped, like a wedge cut from a pie. As with all forms of electromagnetic energy, the
power density from a cellular or PCS transmitter decreases rapidly (according to an inverse square law) as one moves away from the antenna. Consequently, normal ground-level exposure
is much less than exposures that might be encountered if one were very close to the antenna and in its main transmitted beam. Measurements made near typical cellular and pes installations,
especially those with tower-mounted antennas, have shown that ground-level power densities are well below limits recommended by RF/microwave safety standards (References 32, 37, and
45). For example, for a base-station transmitting frequency of 869 MHz the FCC's RF exposure guidelines recommend a Maximum Permissible Exposure level for the public ("general population/uncontrolled
" exposure) of about 580 microwatts per square centimeter ().lW/cm'). This limit is many times greater than RF levels found near the base of typical cellular towers or in the vicinity
of lower-powered cellular base station transmitters, such as might be mounted on rooftops or sides of buildings. Measurement data obtained from various sources have consistently indicated
that "worst-case" ground-level power densities near typical cellular towers are on the order of 1 ).lW/cm' or less (usually significantly less). Calculations corresponding to a "worst-case"
situation (all transmitters operating simultaneously and continuously at the maximum licensed power) show that in order to be exposed to levels near the FCC's limits for cellular frequencies,
an individual would essentially have to remain in 21
the main transmitting beam (at the height of the antenna) and within a few feet from the antenna. This makes it extremely unlikely that a member of the general public could be exposed
to RF levels in excess of these guidelines due to cellular base station transmitters. For PCS base station transmitters, the same type of analysis holds, except that at the PCS transmitting
frequencies (1850-1990 MHz) the FCC's exposure limits for the public are 1000 J.lW/cm'. Therefore, there would typically be an even greater safety margin between actual public exposure
levels and recognized safety limits. When cellular and PCS antennas are mounted at rooftop locations it is possible that ambient RF levels greater than 1 J.lW/cm' could be present on
the rooftop itself. However, exposures approaching or exceeding the safety guidelines are only likely to be encountered very close to or directly in front of the antennas. For sector-type
antennas RF levels to the side and in back of these antennas are insignificant. Even if RF levels were higher than desirable on a rooftop, appropriate restrictions could be placed on
access. Factoring in the time-averaging aspects of safety standards could also be used to reduce potential exposure of workers who might have to access a rooftop for maintenance tasks
or other reasons. The fact that rooftop cellular and PCS antennas usually operate at lower power levels than antennas on free-standing towers makes excessive exposure conditions on rooftops
unlikely. In addition, the significant signal attenuation of a building's roof minimizes any chance for persons living or working within the building itself to be exposed to RF levels
that could approach or exceed applicable safety limits. Vehicle-Mounted Antennus Vehicle-mounted antennas used for cellular communications nonnally operate at a power level of 3 watts
or less. These cellular antennas are typically mounted on the roof, on the trunk, or on the rear window of a car or truck. Studies have shown that in order to be exposed to RF levels
that approach the safety guidelines it would be necessary to remain very close to a vehicle-mounted cellular antenna for an extended period of time (Reference 20). Studies have also
indicated that exposure of vehicle occupants is reduced by the shielding effect of a vehicle's metal body. Some manufacturers of cellular systems have noted that proper installation
of a vehicle-mounted antenna is an effective way to maximize this shielding effect and have recommended antenna installation either in the center of the roof or the center of the trunk.
With respect to rear-window-mounted cellular antennas, a minimum separation distance of 30-60 cm (1 to 2 feet) has been suggested to minimize exposure to vehicle occupants that could
result from antenna mismatch. Therefore, properly installed, vehicle-mounted, personal wireless transceivers using up to 3 watts of power result in maximum exposure levels in or near
the vehicle that are well below the FCC's safety limits. This assumes that the transmitting antenna is at least 15 cm 22
(about 6 inches) or more from vehicle occupants. Time-averaging of exposure (as appropriate) should result in even lower values when compared with safety guidelines. Mobile and Portable
Phones and Devices The FCC's exposure guidelines, and the ANSI/IEEE and NCRP guidelines upon which they are based, specify limits for human exposure to RF emissions from hand-held RF
devices in terms of specific absorption rate (SAR). For exposure of the general public, e.g., exposure of the user of a cellular or PCS phone, the FCC limits RF absorption (in tenns
of SAR) to 1.6 watts/kg (W/kg), as averaged over one gram of tissue. Less restrictive limits, e.g., 2 W/kg averaged over 10 grams of tissue, are specified by guidelines used in some
other countries (Reference 25). Measurements and computational analysis of SAR in models of the human head and other studies of SAR distribution using hand-held cellular and PCS phones
have shown that the 1.6 W/kg limit is unlikely to be exceeded under nonnal conditions of use (References 4, 16,27). The same can be said for cordless telephones used in the home. Lower
frequency (46-49 MHz) cordless telephones operate at very low power levels that could not result in exposure levels that even come close to the 1.6 W/kg level. Higher frequency cordless
phones operating near 900 MHz (near the frequencies used for cellular telephones) operate with power levels similar to or less than those used for cell phones. They are also unlikely
to exceed the SAR limits specified by the FCC under normal conditions of use. In any case, compliance with the 1.6 W /kg safety limit must be demonstrated before FCC approval can be
granted for marketing of a cellular or PCS phone. Testing of handheld phones is normally done under conditions of maximum power usage. However, nonnal power usage is less since it depends
on distance of the user from the base station transmitter. Therefore, typical exposure to a user would actually be expected to be less than that indicated by testing for compliance with
the limit. In recent years, publicity, speculation, and concern over claims of possible health effects due to RF emissions from hand-held wireless telephones prompted industry-sponsored
groups to initiate research programs to investigate whether there is any risk to users of these devices. Organizations such as Wireless Technology Research (funded by the cellular radio
service industry) and wireless equipment manufacturers, such as Motorola, Inc., have been investigating potential health effects from the use of hand-held cellular telephones and other
wireless telecommunications devices. In 1994, the U.S. General Accounting Office (GAO) issued a report that addressed the status of research on the safety of cellular telephones and
encouraged U.S. Government agencies to work closely with industry to address wireless safety issues (Reference 59). In that regard, the Federal Government has been monitoring the results
of ongoing research through an inter-agency working group led by the EPA and the FDA's Center for Devices and 23
Radiological Health. In a 1993 "Talk Paper," the FDA stated that it did not have enough information at that time to rule out the possibility of risk, but if such a risk exists, "it is
probably small" (Reference 58). The FDA concluded that there is no proof that cellular telephones can be hannful, but if individuals remain concerned several precautionary actions could
be taken, including limiting conversations on hand-held cellular telephones and making greater use of telephones with vehicle-mounted antennas where there is a greater separation distance
between the user and the radiating antennas. HOW SAFE ARE FIXED AND MOBILE RADIO TRANSMITTERS USED FOR PAGING AND "TWO-WAY" COMMUNICATIONS? "Land-mobile" communications include a variety
of communications systems which require the use of portable and mobile RF transmitting sources. These systems operate in narrow frequency bands between about 30 and 1000 MHz. Radio systems
used by the police and fire departments, radio paging services and business radio are a few examples of these communications systems. They have the advantage of providing communications
links between various fixed and mobile locations. As with cellular and pes communications, there are three types of RF transmitters associated with land-mobile systems: base-station
transmitters, vehicle-mounted transmitters, and hand-held transmitters. The antennas used for these various transmitters are adapted for their specific purpose. For example, a base-station
antenna must radiate its signal to a relatively large area, and, therefore, its transmitter generally has to use much higher power levels than a vehicle-mounted or hand-held radio transmitter.
Although these base-station antennas usually operate with higher power levels than other types of land-mobile antennas, they are normally inaccessible to the public since they must be
mounted at significant heights above ground to provide for adequate signal coverage. Also, many of these antennas transmit only intermittently. For these reasons, such base-station antennas
have generally not been of concern with regard to possible hazardous exposure of the public to RF radiation. However, studies at rooftop locations have indicated that high-powered paging
antennas may increase the potential for exposure to workers or others with access to such sites, e.g., maintenance personnel (Reference 12). This could be a concern especially when multiple
transmitters are present. In such cases, restriction of access or other corrective actions may be necessary.16 Transmitting power levels for vehicle-mounted land-mobile antennas are
generally less than those used by base-station antennas but higher than those used for hand-held units. As with cellular transmitters, some manufacturers recommend that users and other
nearby 16 Methods and techniques for controlling exposure are discussed in OET Bulletin 65 (Reference 57). 24
individuals maintain a minimum distance (e.g., I to 2 feet) from a vehicle-mounted antenna during transmission or mount the antenna in such a way as to provide maximum shielding for
vehicle occupants. Studies have shown that this is probably a conservative precaution, particularly when the "duty factor" (percentage of time an antenna is actually radiating) is taken
into account since safety standards are "time-averaged." Unlike cellular telephones, which transmit continuously throughout a call, two-way radios normally transmit only when the "press-to-talk"
button is depressed. The extent of any possible exposure would also depend on the actual power level and frequency used by the vehicle-mounted antenna. In general, there is no evidence
that there would be a safety hazard associated with exposure from vehicle-mounted, two-way antennas when the manufacturer's recommendations are followed. Hand-held "two-way" portable
radios such as walkie-talkies are low-powered devices used to transmit and receive messages over relatively short distances. Because of the relatively low power levels used (usually
no more than a few watts) and, especially, because of the intermittency of transmissions (low duty factor) these radios would normally not be considered to cause hazardous exposures
to users. As with vehicle-mounted mobile units, time averaging of exposure can normally be considered when evaluating two-way radios for compliance with safety limits, since these units
are "push to talk.". Laboratory measurements have been made using hand-held radios operating at various frequencies to determine the amount of RF energy that might be absorbed in the
head of a user. In general, the only real possibility of a potential hazard would occur in the unlikely event that the tip of the transmitting antenna were to be placed directly at the
surface of the eye, contrary to manufacturers' recommended precautions, or if for some reason continuous exposure were possible over a significant period of time, which is unlikely.
If hand-held radios are used properly there is no evidence that they could cause hazardous exposure to RF energy (References 5, II, 13, and 27). ARE RF EMISSIONS FROM AMATEUR RADIO STATIONS
HARMFUL? There are hundreds of thousands of amateur radio operators ("hams") worldwide. Amateur radio operators in the United States are licensed by the FCC. The Amateur Radio Service
provides its members with the opportunity to communicate with persons all over the world and to provide valuable public service functions, such as making communications services available
during disasters and emergencies. Like all FCC licensees, amateur radio operators are expected to comply with the FCC's guidelines for safe human exposure to RF fields. Under the FCC's
rules, amateur operators can transmit with power levels of up to 1500 watts. However, most hams use considerably less power than this. Studies by the FCC and others have shown that most
amateur radio transmitters would not normally expose persons to RF levels in excess of safety limits. This is primarily due to the relatively low operating powers used by most amateurs,
the intermittent transmission characteristics typically used and the relative inaccessibility of most amateur antennas. As long as appropriate 25
distances are maintained from amateur antennas, exposure of nearby persons should be well below safety limits. This has been demonstrated by studies carried out by the FCC and others
(Reference 54). If there were any opportunity for significant RF exposure, it would most likely apply to the amateur operator and his or her immediate household. To help ensure compliance
of amateur radio facilities with RF exposure guidelines, both the FCC and American Radio Relay League (ARRL) have developed technical publications to assist operators in evaluating compliance
of their stations (References 23 and 57). CAN IMPLANTED ELECTRONIC CARDIAC PACEMAKERS BE AFFECTED BY NEARBY RF DEVICES SUCH AS MICROWAVE OVENS OR CELLULAR TELEPHONES? Over the past several
years there has been concern that signals from some RF devices could interfere with the operation of implanted electronic pacemakers and other medical devices. Because pacemakers are
electronic devices, they could be susceptible to electromagnetic signals that could cause them to malfunction. Some allegations of such effects in the past involved emissions from microwave
ovens. However, it has never been shown that signals from a microwave oven are strong enough to cause such interference. The FDA requires pacemaker manufacturers to test their devices
for susceptibility to electromagnetic interference (EM I) over a wide range of frequencies and to submit the results as a prerequisite for market approval. Electromagnetic shielding
has been incorporated into the design of modern pacemakers to prevent RF signals from interfering with the electronic circuitry in the pacemaker. The potential for the "leads" of pacemakers
to be susceptible to RF radiation has also been of some concern, but this does not appear to be a serious problem. Recently there have been reports of possible interference to implanted
cardiac pacemakers from digital RF devices such as cellular telephones. An industry-funded organization, Wireless Technology Research, LLC (WTR), working with the FDA, sponsored an investigation
as to whether such interference could occur, and, if so, what corrective actions could be taken. The results of this study were published in 1997 (see Reference 24), and WTR and the
FDA have made several recommendations to help ensure the safe use of wireless devices by patients with implanted pacemakers. One of the primary recommendations is that digital wireless
phones be kept at least six inches from the pacemaker and that they not be placed directly over the pacemaker, such as in the breast pocket, when in the "on" position. Patients with
pacemakers should consult their physician or the FDA if they believe that they may have a problem related to RF interference. 26
WHICH OTHER FEDERAL AGENCIES HAVE RESPONSIBILITIES RELATED TO POTENTIAL RF HEALTH EFFECTS? Various agencies in the Federal Government have been involved in monitoring, researching or
regulating issues related to human exposure to RF radiation. These agencies include the Food and Drug Administration (FDA), the Environmental Protection Agency (EPA), the Occupational
Safety and Health Administration (OSHA), the National Institute for Occupational Safety and Health (NIOSH), the National Telecommunications and Information Administration (NTIA) and
the Department of Defense (DOD). By authority of the Radiation Control for Health and Safety Act of 1968, the Center for Devices and Radiological Health (CDRH) of the FDA develops performance
standards for the emission of radiation from electronic products including X-ray equipment, other medical devices, television sets, microwave ovens, laser products and sunlamps. The
CDRH established a product performance standard for microwave ovens in 1971 limiting the amount of RF leakage from ovens. However, the CDRH has not adopted performance standards for
other RF-emitting products. The FDA is, however, the lead federal health agency in monitoring the latest research developments and advising other agencies with respect to the safety
of RF-emitting products used by the public, such as cellular and PCS phones. The FDA's microwave oven standard is an emission standard (as opposed to an exposure standard) that allows
leakage (measured at five centimeters from the oven surface) of 1 mW/cm' at the time of manufacture and a maximum level of 5 mW/cm' during the lifetime of the oven. l7 The standard also
requires ovens to have two independent interlock systems that prevent the oven from generating microwaves the moment that the latch is released or the door of the oven is opened. The
FDA has stated that ovens that meet its standards and are used according to the manufacturer's recommendations are safe for consumer and industrial use. The EPA has, in the past, considered
developing federal guidelines for public exposure to RF radiation. However, EPA activities related to RF safety and health are presently limited to advisory functions. For example, the
EPA now chairs an Inter-agency Radiofrequency Working Group, which coordinates RF health-related activities among the various federal agencies with health or regulatory responsibilities
in this area. OSHA is responsible for protecting workers from exposure to hazardous chemical and physical agents. In 1971, OSHA issued a protection guide for exposure of workers to RF
radiation [29 CFR 1910.97]. The guide, covering frequencies from 10 MHz to 100 GHz, stated that exposure of workers should not exceed a power density of ten milliwatts per square centimeter
(10 mW/cm') as averaged over any 6-minute period of the workday. However, this guide was later ruled to be only advisory and not mandatory. Moreover, it was " 21 Code of Federal Regulations
1030.10. 27
based on an earlier (1966) American National Standards Institute (ANSI) RF protection guide that has been superseded by revised versions in 1974, 1982 and 1992 (see previous discussion
of standards). OSHA personnel have recently stated that OSHA uses the ANSI/IEEE 1992 guidelines for enforcement purposes under OSHA's "general duty clause" (see OSHA's Intemet Web Site,
listed in Table 3, for further information). NIOSH is part of the U.S. Department of Health and Human Services. It conducts research and investigations into issues related to occupational
exposure to chemical and physical agents. NIOSH has, in the past, undertaken to develop RF exposure guidelines for workers, but final guidelines were never adopted by the agency. NIOSH
conducts safetyrelated RF studies through its Physical Agents Effects Branch. The NTIA is an agency of the U.S. Department of Commerce and is responsible for authorizing Federal Government
use of the RF electromagnetic spectrum. Like the FCC, the NTIA also has NEPA responsibilities and has considered adopting guidelines for evaluating RF exposure from U.S. Government transmitters
such as radar and military facilities. The Department of Defense (DOD) has conducted research on the biological effects of RF energy for a number of years. This research is now conducted
primarily at the DOD facility at Brooks Air Force Base, Texas. In addition, the DOD uses the ANSI/IEEE 1992 standard as a guide for protecting military personnel from excessive exposure
to RF electromagnetic fields. WHERE CAN I OBTAIN INFORMATION ON RF EXPOSURE AND HEALTH EFFECTS? Although relatively few offices or agencies within the Federal Government routinely deal
with the issue of human exposure to RF fields, it is possible to obtain information and assistance on certain topics from the following federal agencies. Most of these agencies also
have Internet Web sites. FDA: For information about radiation from microwave ovens and other consumer and industrial products contact: Center for Devices and Radiological Health (CDRH),
Food and Drug Administration, Rockville, MD 20857. EPA: The Environmental Protection Agency's Office of Radiation and Indoor Air is responsible for monitoring potential health effects
due to public exposure to RF fields. Contact: Environmental Protection Agency, Office of Radiation and Indoor Air, 401 M Street, S.W., Washington, D.C. 20460. OSHA: The Occupational
Safety and Health Administration's (OSHA) Health Response Team (1781 South 300 West, Salt Lake City, Utah 84165) has been involved in studies related to occupational exposure to RF radiation.
OSHA also maintains an Internet World 28
Wide Web site that may be of interest. The URL (case sensitive) is: http://www.oshaslc.gov/SL TCI (select subject: radiofrequency radiation). NIOSH: The National Institute for Occupational
Safety and Health (NIOSH) monitors RFrelated safety issues as they pertain to the workplace. Contact: NIOSH, Physical Agents Effects Branch, Mail Stop C-27, 4676 Columbia Parkway, Cincinnati,
Ohio 45226. Toll-free number: 1-800-35-NIOSH (1-800-356-4674). DOD: Questions regarding Department of Defense activities related to RF safety and its biological research program can
be directed to the Radio Frequency Radiation Branch, Air Force Research Laboratory, Brooks Air Force Base, TX 78235. FCC: Questions regarding potential RF hazards from FCC-regulated
transmitters can be directed to the RF Safety Program, Office of Engineering and Technology, Technical Analysis Branch, Federal Communications Commission, 445 Twelfth Street, S.W., Washington,
D.C. 20554. The telephone number for inquiries on RF safety issues is: 1-202-418-2464. Calls for routine information can also be directed to the FCC's toll-free number: 1-888-CALLFCC
(225-5322). Another source of information is the FCC's RF Safety Internet Web site (http://www.fcc.gov/oetlrfsafety) where FCC documents and notices can be viewed and downloaded. Questions
can also be sent via e-mail to: rfsafety@fcc.gov. In addition to government agencies, there are other sources of information and possible assistance regarding environmental RF energy.
Some states also maintain non-ionizing radiation programs or, at least, some expertise in this field, usually in a department of public health or environmental control. The list of references
at the end of this bulletin can be consulted for detailed information on specific topics, and Table 3 provides a list of some relevant Internet Web sites. 29
TABLE 3. INTERNET WEB SITES FOR FURTHER INFORMATION Note: All Internet addresses below preceded by ''http://''. Also, some URL's may be case sensitive American Radio Relay League: www.arrl.org
American National Standards Institute: www.ansi.org Bioelectromagnetics Society: www.bioelectromagnetics.org COST 244 (Europe): www.radio.fer.hr/cost244 DOD: www.brooks.af.mil/AFRL (select
radiofrequency radiation) European Bioelectromagnetics Association: www.ebea.org Electromagnetic Energy Association: www.elecenergy.com Federal Communications Commission: www.fcc.gov/oetJrfsafety
ICNIRP (Europe): www.icnirp.de IEEE: www.ieee.org IEEE Committee on Man & Radiation: www.seas.upenn.edu/-kfoster/comar.htm International Microwave Power Institute: www.impi.org Microwave
News: www.microwavenews.com J.Moulder, Med.ColI.of Wisc.: www.mcw.edu/gcrc/cop/cell-phone-health-FAQ/toc.html National Council on Radiation Protection & Measurements: www.ncrp.com NJ
Dept Radiation Protection: www.state.nj.us/dep/rpp (select non-ionizing radiation) Richard Tell Associates: www.radhaz.com US OSHA: www.osha-slc.gov/SLTC (select subject: radiofrequency
radiation) Wireless Industry (CTIA): www.wow-com.com Wireless Industry (PCIA): www.pcia.com World Health Organization EMF Project www.who.ch/peh-emf 30
ACKNOWLEDGEMENTS The assistance of the following individuals in reviewing a draft of this bulletin is gratefully acknowledged: Q. Balzano, M. Swicord, 1. Welch (all Motorola, Inc.);
R. Bromery, 1. BurtIe, K. Chan, R.Dorch, B. Franca (all FCC); 1. Elder, N. Hankin (U.S. Environmental Protection Agency); 1. Healer, F. Matos (both NTIA, U.S. Dept. of Commerce); G.
Lotz (National Institute for Occupational Safety and Health); R. Owen (U.S. Food and Drug Administration), R. Petersen (Lucent Technologies). REFERENCES This list is not meant to be
a complete bibliography, but, rather it provides a selection of some of the more relevant and recent references and publications related to this topic. Reports with NTIS Order Numbers
are U.S. Government publications and can be purchased from the National Technical Information Service, U.S. Department of Commerce, (800) 553-6847 1. Adey, W.R., "Tissue Interactions
with Non-ionizing Electromagnetic Fields." Physiological Reviews, 61: 435-514 (1981). 2. American National Standards Institute (ANSI), "Recommended Practice for the Measurement of Potentially
Hazardous Electromagnetic Fields -RF and Microwave." ANSI/IEEE C95.3-1992. Copyright 1992, The Institute of Electrical and Electronics Engineers, Inc. (IEEE), New York, NY 10017. For
copies contact the IEEE: 1-800-678-4333 or 1-908-981-1393. 3. American National Standards Institute (ANSI), "Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic
Fields. 3 kHz to 300 GHz," ANSI/IEEE C95.1-1992 (previously issued as IEEE C95.l-1991). Copyright 1992 by the Institute of Electrical and Electronics Engineers, Inc. (IEEE), New York,
N.Y. 10017. For copies contact the IEEE: 1-800-678-4333 or 1-908-981-1393. 4. Balzano, Q., Garay O. and Manning, T.J. "Electromagnetic energy exposure of simulated users of portable
cellular telephones," IEEE Transactions on Vehicular Technology, Vol. 44 (3), pp. 390-403 (1995). 5. Balzano Q., Garay 0., and F.R. Steel, "Energy Deposition in Simulated Human Operators
of 800-MHz Portable Transmitters." IEEE Trans. Veh. Tech., VT-27(4): 174 (1978). 31
6. Carpenter, D.O. and S. Ayrapetyan, eds., "Biological Effects of Electric and Magnetic Fields, Vol. 2, l Elder: "Thermal, Cumulative, and Life Span Effects and Cancer in Mammals Exposed
to Radiofrequency Radiation." Academic Press, San Diego, (1994). 7. Chou, C.K. et aI., "Long-term, Low-level Microwave Irradiation of Rats." Bioelectromagnetics, 13:469-496 (1992). 8.
Chou, c.K. et aI., "Radiofrequency Electromagnetic Exposure: Tutorial Review on Experimental Dosimetry." Bioelectromagnetics, 17: 195-208 (1996). 9. Chou, C.K., Guy, A.W. and R. Galamboo,
"Auditory Perception of Radiofrequency Electromagnetic Fields." J. Acoust. Soc. Amer., 71: 1321-1334 (1982). 10. Cleary, S. F., "Microwave Radiation Effects on Humans," BioScience, 33(4):
269 (1983). 11. Cleveland, Jr. R.F., and T.W. Athey, "Specific Absorption Rate (SAR) in Models of the Human Head Exposed to Hand-Held VHF Portable Radios." Bioelectromagnetics 10: 173
(1989). 12. Cleveland, Jr., D.M. Sylvar, lL. Vlcek and E.D. Mantiply, "Measurement of Radiofrequency Fields and Potential Exposure from Land-mobile Paging and Cellular Radio Base Station
Antennas." Abstracts, Seventeenth Annual Meeting, Bioelectromagnetics Society, Boston, Massachusetts, p. 188 (1995). 13. Dimbylow, PJ. and S.M. Mann, "SAR Calculations in an Anatomically
Realistic Model of the Head for Mobile Communication Transceivers at 900 MHz and 1.8 GHz," Phys. Med. Bioi. 39(12): 1537-1553 (1994). 14. Foster, K.R., and A.W. Guy, "The Microwave Problem,"
Scientific American, 255(3): 32 (September 1986). 15. Frei, M.R. et aI., "Chronic Exposure of Cancer-prone Mice to Low-level 2450 MHz Radiofrequency Radiation." Bioelectromagnetics,
19: 20-31 (1998). 16. Gandhi, O.P., G. Lazzi and C.M. Furse, "EM Absorption in the Human Head and Neck for Mobile Telephones at 835 and 1900 MHz," IEEE Trans. on Microwave Theory and
Techniques, 44 (10), pp.1884-1897 (1996). 17. Gandhi, O.M. (ed.), Biological Effects and Medical Applications of Electromagnetic Fields, Prentice-Hall, Englewood Cliffs, NJ (1990). 18.
Gandhi, O.P., "Biological Effects and Medical Applications of RF Electromagnetic Fields," IEEE Transactions on Microwave Theory and Techniques, 30(11): 1831 (1982). 32
19. Gandhi, a.p. (ed.), "Biological Effects of Electromagnetic Radiation," IEEE Engineering in Medicine and Biology, 6(1): 14-58 (1987). 20. Guy, A.W., and C.K. Chou (1986). "Specific
Absorption Rates of Energy in Man Models Exposed to Cellular UHF-mobile-antenna Fields." IEEE Trans. Microwave Theory and Tech., MTT -34(6): 671 (1986). 21. Hammett, W.F., "Radio Frequency
Radiation, Issues and Standards." McGraw-Hill, New York (1997). 22. Hankin, N., "The Radiofrequency Radiation Environment: Environmental Exposure Levels and RF Radiation Emitting Sources,"
U.S. Environmental Protection Agency, Washington, D.C. 20460. Report No. EPA 52011-85-014 (1986). 23. Hare, Ed, RF Exposure and You. Published by the American Radio Relay League (ARRL),
Newington, CT 06111, USA (1998). 24. Hayes, D.L. et aI., "Interference with Cardiac Pacemakers by Cellular Telephones." New England J. or Medicine, 336: 1473-1479 (1997). 25. International
Commission on Non-Ionizing Radiation Protection (ICNIRP), "Guidelines for Limiting Exposure to Time-varying Electric, Magnetic, and Electromagnetic Fields (Up to 300 GHz)," Health Physics
74: 494-520 (1998). 26. Klauenberg, B.J., Grandolfo, M. and D.N. Erwin (eds.), Radiofrequency Radiation Standards, Biological Effects, Dosimetry. Epidemiology and Public Health Policy.
NATO ASI Series A: Life Sciences, Plenum Press (1994). 27. Kuster, N., Q. Balzano and J. Lin, Eds., Mobile Communications Safety, Chapman and Hall, London, (1997). 28. Lai, H. and N.P.
Singh, "Single-and Double-strand DNA Breaks in Rat Brain Cells After Acute Exposure to Radiofrequency Electromagnetic Radiation." IntI. J. Radiation Biology, 69: 513-521 (1996). 29.
Lai, H. and N.P. Singh, "Acute Low-Intensity Microwave Exposure Increases DNA Single-strand Breaks in Rat Brain Cells." Bioelectromagnetics, 16:207-210 (1995). 30. Malyapa, R.S. et aI.,
"Measurement of DNA Damage Following Exposure to 2450 MHz Electromagnetic Radiation." Radiation Research, 148: 608-617 (1997). 31. Malyapa, R.S. et aI., "Measurement of DNA Damage Following
Exposure to Electromagnetic Radiation in the Cellular Communications Frequency Band (835.62 and 847.74 MHz)." Radiation Research, 148: 618-627. 33
32. Mantiply, E.D., "Summary of Measured Radiofrequency Electric and Magnetic Fields (10 kHz to 30 GHz) in the General and Work Environment." Bioelectromagnetics, 18: 563-577 (1997).
33. National Council on Radiation Protection and Measurements (NCRP), "Radiofrequency Electromagnetic Fields; Properties, Quantities and Units, Biophysical Interaction, and Measurements,"
NCRP Report No. 67 (1981). Copyright NCRP, Bethesda, MD 20814, USA. For copies contact: NCRP Publications at 1-800-229-2652. 34. National Council on Radiation Protection and Measurements
(NCRP), "Biological Effects and Exposure Criteria for Radiofrequency Electromagnetic Fields," NCRP Report No. 86, (1986). Copyright NCRP, Bethesda, MD, 20814, USA. For copies contact
NCRP Publications: 1-800-229-2652. 35. National Council on Radiation Protection and Measurements (NCRP), "A Practical Guide to the Determination of Human Exposure to Radiofrequency Fields,"
NCRP Report No. 119, (1993). Copyright NCRP, Bethesda, MD 20814. For copies contact: NCRP Publications at: 1-800-229-2652. 36. Petersen, R.C., "Bioeffects of Microwaves: A Review of
Current Knowledge," Journal of Occupational Medicine, 25(2): 103 (1983). 37. Petersen, R. and P. Testagrossa, "Radio-Frequency Electromagnetic Fields Associated with Cellular-Radio Cell-Site
Antennas." Bioelectromagnetics, 13:527 (1992). 38. Petersen, R.C., "Electromagnetic Radiation from Selected Telecommunications Systems." Proceedings IEEE, Vol. 68, No.1, p. 21-24 (1998).
39. Repacholi, M.H., A. Basten, et. aI., "Lymphomas in E~-Piml Transgenic Mice Exposed to Pulsed 900 MHz Electromagnetic Fields." Radiation Research, 147:631-640 (1997). 40. Repacholi,
M.H., "Low-Level Exposure to Radiofrequency Electromagnetic Fields: Health Effects and Research Needs." Bioelectromagnetics, 19: 1-19 (1998). 41. Schwan, H.P., "Biological Effects of
Non-ionizing Radiation: Cellular Properties and Interactions." Ann. Biomed. Eng. 16: 245-263 (1988). 42. Tell, R.A., "A Measurement of RF Field Intensities in the Immediate Vicinity
of an FM Broadcast Station Antenna," Technical Note ORP/EAD-76-2, U.S. Environmental Protection Agency, Las Vegas, NV (1976). NTIS Order No. PB 257698. 43. Tell, R.A., "Electric and
Magnetic Fields and Contact Currents Near AM Standard Broadcast Radio Stations," Richard Tell Associates, Inc., Las Vegas, NV. Project performed under contract for Federal Communications
Commission (FCC), Office of Engineering and 34
Technology, Washington, D.C. 20554. FCC Report No. OET/RTA 89-01 (1989). NTIS Order No. PB 89-234850. 44. Tell, R.A., "Induced Body Currents and Hot AM Tower Climbing: Assessing Human
Exposure in Relation to the ANSI Radiofrequency Protection Guide," Richard Tell Associates, Inc., Las Vegas, NV. Project performed under contract for Federal Communications Commission
(FCC), Office of Engineering and Technology, Washington, D.C. 20554. FCC Report No. OET/RTA 91-01 (1991). NTIS Order No. PB 92-125186. 45. Tell, R.A., "Engineering Services for Measurement
and Analysis of Radiofrequency (RF) Fields," Richard Tell Associates, Inc., Las Vegas, NV. Project perfonned under contract for Federal Communications Commission (FCC), Office of Engineering
and Technology, Washington, D.C. 20554. FCC Report No. OET/RTA 95-01 (1995). NTIS Order No. PB 95-253829. 46. Tell, R. A. and E. D. Mantiply, "Population Exposure to VHF and UHF Broadcast
Radiation in the United States," Proceedings of the IEEE, Vol. 68(1), pages 6-12 (1980). 47. Toler, lC. et aI., "Long-term Low-level Exposure of Mice Prone to Mammary Tumors to 435 MHz
Radiofrequency Radiation." Radiation Research, 148: 227-234 (1997). 48. U.S. Environmental Protection Agency, authors Tell, R. A., and E. D. Mantiply, "Population Exposure to VHF to
UHF Broadcast Radiation in the United States," Technical Note ORP/EAD 78-5 (1978). NTIS order No. PB 284 637. 49. U.S. Environmental Protection Agency, "Biological Effects of Radiofrequency
Radiation," Report No. EPA-600/8-83-026F (1984). NTIS Order No. PB85-120848. 50. U.S. Environmental Protection Agency, Electromagnetics Branch, Las Vegas, NV 89114. "An Investigation
of Radiofrequency Radiation Levels on Lookout Mountain, Jefferson County, Colorado," (1987). 51. U.S. Environmental Protection Agency, Office of Radiation Programs, "Radiofrequency Electromagnetic
Fields and Induced Currents in the Spokane, Washington Area," EPA Report No. EP N520/6-88/008 (1988). NTIS Order No. PB88-2448191 AS. 52. U.S. Environmental Protection Agency, Office
of Radiation Programs, "Electric and Magnetic Fields Near AM Broadcast Towers," EPA Report No. EPN520/6-911020, (1991). NTIS Order No. PB92-101427. 53. U.S. Environmental Protection
Agency, Office of Air and Radiation and Office of Research and Development, "Summary and Results of the April 26-27, 1993 Radiofrequency Radiation Conference." Vol. I: Analysis of Panel
Discussions, EPA Report No. 402-R-95-009, (1995); Vol. 2: Papers, EPA Report No. 402-R-95-011, (1995). 35
54. U.S. Federal Communications Commission (FCC), Office of Engineering and Technology, "Measurements of Environmental Electromagnetic Fields at Amateur Radio Stations," FCC Report No.
FCC/OET ASD-9601, February 1996, Washington, D.C. 20554. NTIS Order No. PB96-1450 16. Copies can also be downloaded from OET's Home Page on the World Wide Web at: http://www.fcc.gov/oet/.
55. U.S. Federal Communications Commission (FCC), "Guidelines for Evaluating the Environmental Effects of Radiofrequency Radiation," Report and Order, ET Docket 93-62, FCC 96-326, adopted
August 1, 1996, 61 Federal Register 41006 (1996). 56. U.S. Federal Communications Commission (FCC), "Guidelines for Evaluating the Environmental Effects of Radiofrequency Radiation,"
Second Memorandum Opinion and Order and Notice of Proposed Rule Making, ET Docket 93-62 (WT Docket 97-192), FCC 97-303, adopted August 25, 1997,62 Federal Register 47,960,49,557 and
61,447 (1997). 57. U.S. Federal Communications Commission, Office of Engineering and Technology, "Evaluating Compliance with FCC-Specified Guidelines for Human Exposure to Radiofrequency
Radiation," OET Bulletin 65, Edition 97-01, August 1997, Washington, D.C. 20554 [NTIS Order No. PB86-127081]. Three supplements to this bulletin have also been issued: Supplement A (additional
information for radio and television broadcasters), Supplement B (additional information for amateur radio operators), and Supplement C (additional infonnation for evaluating mobile
and portable RF devices). Copies of the bulletin and supplements can be obtained by contacting the FCC's RF Safety Program at: (202) 418-2464 or by downloading from the OET Internet
Web site: http://www.fcc.gov/oetlrfsafety. 58. U.S. Food and Drug Administration, Rockville, MD 20857. "FDA Talk Paper, Update on Cellular Phones." FDA Ref. No. T93-7, February 4, 1993.
59. U.S. General Accounting Office, "Status of Research on the Safety of Cellular Telephones." Report No. GAO/RCED-95-32 (1994). Available from GAO, P.O. Box 6015, Gaithersburg, MD 20884-6015,
1-202-512-6000. 36