HomeMy WebLinkAboutApplication.pdf,._,...-----------------...... ·--->">'<•-·-A---------------. TYPE OF CONSTR UCTION I
Gl Commercial/Multi·Famlly I CJ Demolitio n !
0 Manufactured Home (SF or Duplex) I
CJ Residential (SF, Duplex, or To wnhome) I CJ Reroof I
INVOLVED P~RTIES
.....-~~~~~~--------------~~-~~--~~-----!
Property owner: OXY USA WTP LP Phone: ( 970 )_2_63_·3_6_0_7 __ --t
Mailing Address: 760 Horizon Drive , Suite 101 Grand Junction, CO 81506
Contractor: DIA Construction, Inc. Phone: ( 970 ) 283-5706
Mailing Address: 2171West1-70 Frontage Road, DeBeque, CO 81630
Archftect: __________________ Phone: ( _ _, ______ _
l) Malling Address: __________________________ _
Engineer: DR Griffin and Associates, Inc. Phone: ( 307 )_3_62_-_50_2_a ___ _
Mailing Address : 1414 Elk. St, Suite 202 Rock Springs, WY 82901
Man ufactu red Home I nstaller: ___________ Phone:( __ } ______ _
Mailing Address:
.__ .. __ ... .._ __ .... ~
PROJECT NAME AND ·LOCATION
Describe Work: Do uble Layer Ch ai n Link Perimeter Fence for the BOCC Approved Pond 10 Water
lmpoundment
Job Address: SE 1/4 SW 1/4 Section 5, Township 7 South, Range 97 West, 6th PM in Garfield County
Assessor's Parcel Number: 216S.214-0026 Su b. Lot --Bl oc k -
Owner's Valuation of Wo rk: $ 40,000 Property Size (Sq.Ft or Acres): rT-32-
Sq.Ft of Building: Height: #of Floors:
Class of Work: l!I New I CJ Alteration ID Addition I Cl Repair j CJ Move/Relocati on
i CJ Attached 1 CJ Detached --Garage:
l
) Septic: CJ ISDS I D Community
--Type of Heat: Cl Natural Gas ' CJ Propane , . D Electric I D Other
I
Dr iveway Permit: [!]Exempt
_ _I
CJ Permit#:
) .
\
)
NOTIGE
Authority. This applicatlon for a Bulldlng Permit must be signed by the Owner of the property, described above, or :
an authorized agent. If the signature below Is not that of the Owner, a separate letter of authority, signed by the
Owner, must be provided with this Appllcatlon .
' legal Access . A Building Permit cannot be issued without proof of legal and adequate access to the property for
· purposes of Inspections by the Building Division.
Other Permits. Multiple separate permits may be required : (1) State Electrical Permit, (2) County ISDS Permit, (3)
another permit required for use on the property identified above, e.g. State or County Highway/ Road Access or a
State Wastewater Discharge Permit.
Void Permit. A Building Permit becomes null and vold If the work authorized Is not commenced within 180 days of
the date of issuance and if work Is suspended or abandoned for a period of 180 days after commencement .
CERTIF.IGATION
I hereby certify that I have read this Appllcat lon and that the Information contained above Is true and correct. I
understand that the Building Division accepts the Applicatlon, along with the plans and specifications and other
data submitted by me or on my behalf (subm lttals), based upon my certification as to accuracy. Assuming
completeness of the submlttals and approval of this Applfcatfon, a Bulldlng Permit wlll be Issued granting
1 permission to me, as Owner, to construct the structure(s) and facilltles detailed on the submlttals reviewed by the 1
: Bulldlng Division. In consideration of the Issuance of the Building Permit, I agree that I and my agents will comply
with provisions of any federal, state or tocal law regulating the work and the Garfield County Build Ing Code, ISDS
regulations and applicable land use regulations (County Regulation(s)l. I acknowledge that the Building Permit
may be suspended or revoked, upon notice from the County, If the location, construction or use of the structure(s)
and faclllty(ies), described above, are not In compliance with County Regulatlon(s) or any other applicable law.
I hereby grant permission to the Building Division to enter the property, described above, to Inspect the work. I
further acknowledge that the Issuance of the Building Permit does not prevent the Bulldlng Official from : (1)
requiring the correction of errors In the submlttals, If any, discovered after issuance; or (2) stopping construction
or use of the structure(s) or facillty(les) if such Is In violation of County Regulation(s) or any other appllcable law.
Review of this Appllcatlon, Including submlttals, and Inspections of the work by the Building Division do not
constitute an acceptance of responsibility or liability by the County of errors, omissions or discrepancies. As the
Owner, I acknowledge that responsibility for compllance with federal, state and local laws and County Regulations 1
1
1
rest with me and my authorized agents, lndudlng without llmitatlon my architect designer, eng inee r and/ or
builder. '--~~~~~~~~~~~~~~~~~~~~-~-~~~~~~~~~~~~~~
I hereby acknowledge that I have read and understand the Notice and Certification above as well as
have provided the required lnfonnation which is correct and accurate to the best of my knowledge.
Property Owner Print and Sign Date
{OFFIBA~USE 6N1;y .. r -· .. ··--· -..
t.O:...:.:~,.. .. ~~..:.:.O...'IO..'lo "'" .. -----.~ ... ·---~~;;J .~<..;.1 •
Sped1I Conditions:
Adjusted Valuation: Plan Chedc Fee: Permit Fee: M1nu home Fee: Misc Fees:
40000 -'1/)2 .~ 542 . 75 ~\~ tJI~ ,/ ~
Total Fees : Fees Paid: B;ilance Due: I!!!!!: 1$0SNo:
B9S. 54 ?S'--·14 54Z.7S-BL-CO -32.5'1 ~I~
Setbacks: OCCGroup: Const Type: Zoning:
I ( I LA. :rx.!3-R Fz..5. Uf,5 10
BUILDING/ PLANNING DIVISION : ):'},,~ 6//6/;'f-
I J Slaned Approval Data
~ -f 2 $' I
, ... , ';fl
Building Plan Review
Description of Work: double layer chain link perimeter fence to keep out wildlife for the BC
Bin#:
Location Address: 4110 C R 21 3 RD
DE B EQ UE,CO
Ca se Manager: David Bartholomew
Pla n C as e Number: BLDG-6-14-7960
Parcel: 21 692 140002 6
Application Date: 0610912 014
Building
fJ;A _____ Engineered Foundation
___ rJ_(,__A_Driveway Permit
----'-/ __ Surveyed Site Plan
__ µ,-+1_A __ Septic Permit and Setbacks
---+---Grade/Topography 30%
_____ Attach Residential Plan Review List
----+--Minimum Application Questionnare
--~--Subd i vi sion Plat Notes
_____ Fire Department Review
__ _,/~ __ Valuation Determination/Fees
___ / ___ Red Line Plans/Stamps/Sticker
/
------'Attach Conditions
___ / ___ Applicati on Signed
__ ..._/ ___ Plan Reviewer To Sign Application
___ / __ ~Parcel/Schedule No.
__ k_.tj_/J __ 40# Snowload Letter -Manu. Homes
__ N ..... /_/l---'Soils Report
Monday, June 16, 2014
Contacts
Own er: OXY USA WTP LP
Applicant: OXY USA WTP LP
Applicant Phone : Email:
Planning/Zoning
/
Property Line Setbacks
/ 30ft Stream Setbacks
/ Flood Plain
N(A Building height
/ oning Sign-off
;v/11 Road Impact Fees
;v/A-HOA/DRC Approval
/ Grade/Topography 40%
I Planning Issues
/
-----S'ubdivision Plat
General Comments:
l/Ait4J~
f 4 0~.~ /1-$ suPJ/#;;fec/
/
NOTE: If any required information is missing, delays in issuing the permit are to be expected. If
determined by the Bu~ding Official that additional information is necessary to review the application
and/or plans for compliance, the application may be placed on hold until the required information is
provided. Work may not proceed without the issuance of a permit.
The Building Division will collect a Plan Review fee at time of application submittal. The Permit Fee, as
well as any Septic or Road Impact fees will be collected when the permit is issued.
The permit application must be signed by the owner or by a person having written authority from the
owner to act as their representative.
I hereby acknowledge I have read, understand, and will abide with the requirements of this
checklist.
<
5 > June 3, 2014
Property Owner Print and Sign
c:E Garfield Coun~
Commu.nity Development Department
108 8th Street, Suite 401
Glenwood Springs, CO 81601
(970) 945-8212
www.garfield-countv.com
COMMERCIAL OR
MULTI-FAMILY
BUILDING PERMIT
APPLICATION CHECKLIST
COMMERCIAL OR MULTI-FAMILY BUILDING PERMIT APPLICATION CHECKLIST
In order to un derstand the scope of work intended and to expedite the issuance of a permit, it is
important that complete information be provided . Please review this document to determ ine if you have
adequate information to design your project and to faci li tate a plan review .
APPLICATION FORM : Please make sure the following information is provided on the application .
• Parcel number obtained from the County Assessor's Office .
• Job address (assigned physical address).
• Legal Description: lot, block , filing , subdiv ision or tract, section, township and range.
• Owners name, mailing address , phone, fax , or cell.
• Contactors name, mailing address, phone, fax, or cell.
• ArchitectlEngineer's name, ma iling address, phone , fax or cell.
• Build ing size , height , number of stories, lot size.
• Use of bu ilding (commercia l)
• Class of Work (new, addition, alteration, repair, demo, move , other)
• Description of work.
• Type of heating (natural gas, propane, electric, other)
• Sewer system (Community or ISDS), also see other items below.
• Garage (attached or detached)
• Driveway permit (please see other items below)
• Valuation (labor and materials)
OTHER ITEMS:
• If you anticipate obtain ing a water-tap from the City of Rifle, please provide a letter indicating that
the City will provide water service . (Required to submit building permit application).
• ISDS requires a septic permit application to be submitted with the building permit application.
• A separate electrical permit must be obtained from the State of Colorado Electrical Board .
• At the ti me of building permit submittal, you are required to show proof of legal and adequate
access to the site . This may include proof of right to use a private easement, County Road &
Bridge permit, or Colorado Department of Highway permit, including a Notice to Proceed . The
County Road & Bridge Department can be reached at 970-625-8601 .
• If you anticipate excavating or grading prior to issuance of a building permit, you will be requ ired
to obtain a separate grading permit.
• If you belong to a Homeowners Association, it is your responsibility to obtain written approval , if
required .
• Provide copies of any Resolutions and/or Land Use Permits associated with this property.
• Projects with more than 1 O occupants require plans sealed by a Colorado Licensed Design
Professional. Occupant load shall be calculated by IBC Table 1004.1.1.
• A Colorado State Licensed Electrician and Plumber must perform installatio n and hook-ups.
BUILDING PLANS: 2 sets of plans must be submitted. Plans must be 18"x24" minimum size, complete,
identical, legible, and to scale. Certain projects may also require a third copy of the plans be submitted to
the local Fire District for review prior to permit issuance. All plans will be checked at the counter for
completeness. If any of the required information is missing, the building permit application cannot be
accepted. ·
SITE PLAN: Please make sure the following information is provided on the site plan.
• Property address/legal description.
• North Arrow and Scale on each page.
• Show all property lines, building envelopes, flood plain, and easements.
• Provide setback distances from boundaries, buildings, septic, well, and waterways.
• Location and direction of the county or private road and driveway accessing the property.
• Proposed and existing structures include sheds, barns, decks, patios, and any other buildings.
• Existing and proposed grade, positive drainage around structure (to be contained on site).
• Streams, rivers, creeks, springs, ponds and ditches.
• Existing and proposed wells, septic tanks, leach fields, and other systems. (if applicable)
• Retaining walls (engineer stamped detail required for walls over 4 fl, measured from bottom of
footing to top of wall).
NOTE: Any site plan depicting the placement of any portion of the structure within 50 feet of a property
line or not within an established building envelope shall be prepared, stamped, and signed by a licensed
surveyor. For structures to be built within a building envelope, provide a copy of the recorded subdivision
final plat with the proposed structure located in the building envelope.
COVER SHEET:
• Project identification.
• Project address and/or legal description.
• Design specifications to include building use and occupancy classification, type of construction,
building height and area calculations, occupant load, and fire sprinkler systems.
ARCHITECTURAL PLANS: Please provide the following information on the architectural plans.
• Per C.R.S. 12-4-112; Structures designed with an occupant load exceeding 10 require Colorado
State Licensed Design Professional stamped plans.
• Minimum 4 elevations (N,S,E,W)
• Floor plans for each level including dimensions and scale noted.
• Clearly label each room or space (office, storage, mechanical, elevator, etc).
• Wall types; clearly labeled and referenced. Identify all fire resistive wall construction.
• construction details for all fire resistive elements referenced on floor plans and cross sections.
Include wall, floor/ceiling, roof/ceiling, shaft wall assemblies, and structural frame. Provide the fire
resistive listing number referenced on each assembly detail. (ex. UL P123)
• Window & door sizes, types, and operation and direction of swing noted on the floor plan.
• Specify roof slope/pitch, roof covering, and siding materials.
• Energy design specifications/details for R-values, U-factors, and SHGC's per IECC.
• Stair and guard details specifying rise, run, height and spacing.
• Accessibility; show compllance with accessibility requirements for all elements of the building per
IBC, Chapter11 and ICC/ANSI A 117.1, ADA, FHA, and UFAS.
STRUCTURAL PLANS: Please provide the following information on the structural plans.
• Per C.R.S. 12-4-112; Structures designed wilh an occupant load exceeding 10 require Colorado
State Licensed Engineer stamped plans.
• Engineered foundation design per soils report. Geotechnical report referenced.
• Design specifications to include roof and deck snow load, wind and seismic design, frost depth.
• Foundation plan showing complete footing and foundation dimensions.
• Footing and foundation details specifying reinforcement referenced on plans.
• Framing plans for each floor level and roof. All beams, columns, joists, rafters, trusses and all
live/dead loads specified.
• Framing /connection details referenced on plans.
• Pre-manufactured structures require an engineers stamp, signature, and date.
MECHANICAL PLANS: Please provide the following information on the mechanical plans.
• Per C.R.S. 12-4-112; Structures designed with an occupant load exceeding 10 require Colorado
State Licensed Engineer stamped plans.
• Energy design calculations and details verifying compliance with the 2009 IECC.
• Floor plans for each level showing size, location and materials of all ductwork, plenums, return
and outside air intake registers.
• Size and location of all combustion air ductwork and openings.
• Size, type and termination of all gas appliance flues and vents.
• Location of all fire and combination smoke/fire dampers.
• Equipment schedule for all mechanical equipment (boiler, furnace, exhaust fans, etc).
• Commercial kitchen hood location, hood and duct sizes, CFM calculations.
PLUMBING PLANS: Please provide the following information on the plumbing plans.
• Per C.R.S. 12-4-112; Structures designed with an occupant load exceeding 1 O require Colorado
State Licensed Engineer stamped plans.
• Floor plans for each level showing DWV layout and sizing, materials, slope and sewer location.
• Water piping materials, length and size of pipe, water meter location, fixture unit demands,
location and type of backflow prevention devices.
• Gas piping materials, length and size of pipe, gas meter location, and BTU/hour demands.
• Additional piping plans for roof/deck drains, condensate, medical gas, etc.
• Plumbing fixture schedule for all plumbing equipmenl
• Commercial kitchen plumbing fixtures, food preparation equipment, grease interceptors, etc.
ELECTRICAL PLANS: Please provide the following information on lhe electrical plans.
• Per C.R.S. 12-4-112; Structures designed with an occupant load exceeding 10 require Colorado
State Licensed Engineer stamped plans.
• Floor plans for each level showing location of lighting fixtures, switches, receptacles, emergency
exit signs and lighting, and panel location.
• Diagram showing service entrance, conduit/wire size, main disconnect size, grounding
electrode/conductor size, feeder conduit/wire size, transformers and generators.
• Panel schedule showing bus/breaker sizes, circuit description, voltage, phase, amperage, etc.
Approved Pond 10 Water Impoundment and Storage Site
Wildlife Deterrent Fencing
Building Permit Application Narrative
OXY USA WTP LP
Pond 10
OXY USA WTP LP (OXY) is pursuing a Building Permit for chai n-linked fenc ing surrounding the
approved water impoundment pond site (Pond 10) in Garfield Cou nty. The site was approved by
the BOCC on May 19, 2014. The subject applicatio n is for two layers of perimeter fencing that will
deter wildlife and livestock for entering the water impoundment. The site is located on private
property, owned by OXY USA WTP LP, approximately 12 miles north ofDeBeque, Colorado.
Description
The site is defin ed as a Wa ter lmpoundme nt with storage as a n accessory use. The facility's main
function will be to store produced water in a location centralized to OXY 's production field.
The subject generator provided power to pumps required for the Pond 10 operations. The
proposed s ite will be 9.835 acres. The site is located within the 7732 acre parcel. An access road to
the si te lo cation is maintained a nd owned by OXY.
Two layers of fencing w ill be installed to deter wildlife from entering the water impoundment
perimeter. The proposed fence will be a height ofB-feet and will be installed around the perimeter
of Pond 10. Th e fence will be chain link with a wildlife mesh extending 1 foo t below grad e and 2 feet
above grade attached to the 8-feet chain link fence. The wildlife mesh wi ll prevent small animals
from e ntering the site. Fencing dimensions are approxi mate ly 327 feet by 235 feet and 316 feet by
224 feet. Fencing details are provided in the subject building permit applicatio n.
The fe n ce will not exceed the maximum height restriction (8 fee t) for the Resource Lands-Gentle
Slopes zone district. The fence is required for th e proposed use to deter wildlife and livestock from
e nteri n g the s ite , will not adver sely impact t he operation of any adjacent public right-of-way or
roads, will not impact the natural li gh ting or visual corridor o f a dj acent properties, and w ill not
obstruct critical traffic areas a long roadways. The Environm ental Impact Assessment, included in
the Building Permit applic ation, described the requirement for fencing of the subject use. The
fencing will be constructed to meet Co lorado Park and Wildlife (CPW) standards a nd was approved
by CPW . Proposed fencing a lso meets all appl icable zone district standards.
DR Griffin and Associates designed the fencing perimeter. Taylor Fence Company is the fence a nd
materials supplier. DIA construction is contract ed to insta ll the perimeter fencing. All contacts are
provided on the application form.
Purpose and Need
The proposed water impoundment site will result in improved efficiency in transportation and use
of produced water. The proposed site is located on OXY's property and within the Cascade Creek
field. Pond 10 will support existing wells in the Casca d e Creek field and the completion of future
wells on Cascade Creek acreage for the Mesa, Valley, and Logan Wash areas. The Pond 10 site is
critica l to OXY's ability to produce natural gas in Garfield Co unty.
Location
The Pond 10 s ite plan is designed to be approximately 9.835 acres and will be southe rly located on
parcel 2169-214-00-026, in the Southeast% of the So uthw est% of Section 5, Towns hip 7 South,
Range 97 West of the 6th Principal Meridian, Garfield County. The subject parcel is approximate ly
7732 acres. OXY USA WTP LP, the applicant, is the owner of the property a nd th e sole owner of
Build ing Permit Application Narrative
Garfield Cou nty Limited Impact Review, 2014 Page 1 of3
OXY USA WTP LP
Pond 10
mineral rights for the subject parcel. The subject parcel is zoned resource lands-gentle slopes. All
adjacent parcels are zoned resource lands or public lands.
Building Permit Application Narrative
Garfield County Limited Impact Review, 2014 Page 2 of3
Site Plan
Building Permit
Required Documents
A Site Plan is provided on a 24 X 36 inch sheet.
Architectural Plans
OXY USA WTP LP
Pond 10
Fencing details and plans are provided in the subject building permit application.
Structural Plans
No foundation will be required for the proposed fencing. Structural plans are not applicable
to the subject building permit application .
Mechanical Plans
No mechanical plans will be required for the proposed fencing. Mechanical plans are not
applicable to the subject building permit application.
Plumbin1: Plans
No plumbing will be installed pertaining to the proposed fencing. Plumbing plans are not
applicable to the subject building permit application.
Electrical Plans
No electricity will be installed or required perta ining to the proposed fencing. Electrical
plans are not applicable to the subject buil ding permit appl icati on .
Building Permit Application Narrative
Garfield County Limited Impact Review, 2014 Page3of3
)
'fAVJ .O ~ t I :1 :NCI '. CO IVI PA NV 0 1: GI lANIJ lJU l\I C'flO N
n32 ?.1 1/2 110/\D P.O . IJ OX :I 12G
FABRIC:.
TOP HAIL:
LINEPOST:
TERMINAL:
GATE POST:
BRACING:
FITTINGS:
TIE WllH~:
GATES:
POST FOOTING:
C:dl/\ND .JUN CT IO N, CO 13150?.
9'10-21\ 1 -1'1'/~3
FAX 970-?.'1 '1-ltll[i
SYMB()l OF QUALRlY Al'\I D VV O RKMAN SID UP
CHAIN LINK FENCE SJ>l!:CJFICATION
OX\' USA INC
CONN CHEEK POND FENCI!:
96" 9 GA GALVANIZED (2" MESH) CHAIN LINK FABRIC.
I 5/8" O.D. SS40 STRUC TURAL PIPE, 1.82 LBS PER FOOT.
TOP RAIL IN 2 1' LENGTH, WITH SLEEVES .
2 3/8" O.D. SS40 STRU CTURAL Pf PE, 2.28 LBS PER FOOT.
LIN E POSTS SET 10' ON CENT ER MAXIMUM SPACTNG.
3" O.D. SS40 STRUCTURA L PIP E, 4.64 LBS PER FOOT.
6 5/8" O.D . SS40 STRUCTURAL PIPE , 19 .5 LBS PER POOT.
I 5/8 O.D. SS40 STRU CTURA L PIPE , 1.8 2 LBS PER FOOT.
REGULAR BRACE BAND AND CARRIAGE BOLT, PRESSED
STEEL RAIL, PRE SS ED STEEL CAP, PRESSED STEEL LINE
TOP S, '.V I G X Y.1" TEN S ION 13AR, REGULAR T EN SION BAND
/\ND CARRIAGE BOI :r.
8 ·Yi" 9 GA STEEL WIRE SPACED 15" ON CENTE R FOR LINE
POST AND 12" ON C ENTER FOR RAIL.
I 5/8" SS4 0 STRU CTURAL PIPE FRAME, FABRI C SAME AS
ABOVE.
HOLE DIMENSION FOR LI NE PO ST 8" X 30", TERMINAL
POST I O" X 36", CO NCRETE 3000 PSI