Loading...
HomeMy WebLinkAboutApplication.pdfGARFIELD COUNTY BUILDING PERMIT APPLICATION 108 8th Street, Suite 401, Glenwood Springs, Co 81601 Phone: 970-945-8212 / Fax: 970-384-3470 / Inspection Line: 888-868-5306 www.garfield-countv.com 1 . — Parcel No: (this information is available at the assessors office 970-945-9134) /)9/2()Do-33 2 an re(if an dr s has not been assigned, please provide Cr, Hwy or Street Name & City) or and legal de ption JoHil t /3,2 6L iv 4' _ 'i/'5 (Q -Z_ / 3 Lot No: Block No: Subd./ Exemption: �� 4 r1/V /^ pe-tY s er) L //A/4/ / In Ad � f / 6,5, eo P 7 '✓ ©/ It z 5 C actor, / /' "If/),,,,,,4,7 Mailing Addre y, Ph: Alt Ph: 6 chitect / En ineer: a5/'sy' ,r0/i/vey�l�r%t10 ailin d ass: x,46//y P . ,�11t flu 9 y 5 o Ph: 7 Sq. Ft. o Building: Sq. Ft. or tic/es / Height: N° of o / AKFh: �/ 8 Use of Id' 9 Describe W/pb lq.o 2t)c)/zii gl/gy li-Org'emi,s/7-/A/ c 10 Class of Work: �� ��� � ,/ Ne w teration o/Addition ^�y> � li �' `Y (� 11 Garage: o Atta ed �etached Septic: o ISDS o Community 12 Driveway Permit:////QQ/n//� A) Ownersaluation of Work: $ Authority. Tbis application for a Building Permit ust be signed by letter of authority, signed by the O r, must be provided A Building Permit cannot be issued without proof of legal NOTICE the Owner of the property, described above, or an authorized agent. If the signature below is not that of the Owner, a separate with this Application and adequate access to the property for purposes of inspections by the Building Department. Electrical Permit, (2) County ISDS Permit, (3) another permit required for use on the property identified above, e.g. State or Discharge Pet -mit. is not commenced within 180 days of the date of issuance and if work is suspended or abandoned for a period of 180 CERTIFICATION contained above is true and correct 1 understand that the Building Department accepts the Application, along with the plans based upon my certification as to accuracy. a Building Permit will be issued granting permission to me, as Owner, to construct the structure(s) and facilities detailed on my agents will comply with provisions of any federal, state or local law regulating the work and the Garfield County Building I acknowledge that the Building Permit may be suspended or revoked, upon notice from the County, if the location, are not in compliance with County Regulation(s) or any other applicable law. described above, to inspect the work. I further acknowledge that the issuance of the Building Permit does not prevent the if any, discovered after issuance; or (2) stopping construction or use of the structure(s) or facility(ies) if such is in violation work by the Building Depart hent do not constitute an acceptance of responsibility or liability by the County of errors, omissions compliance with federal, state and local laws and County Regulations rest with me and my authorized agents, including without Ly THE NOTICE & CERTIFICAT ON ABOVE: Leeal Access. Other Permits. Multiple separate permits may be required: (1) State County Highway/ Road Access or a State Wastewater Void Permit. A Building Permit becomes null and void if the work authorized days after commencement I hereby certify that I have read this Application and that the information and specifications and other data submitted by me or on my behalf (submittals), Assuming completeness of the submittals and approval of this Application, the submittals reviewed by the Building Department In consideration of the issuance of the Building Permit, I agree that I and Code, ISDS regulations and applicable land use regulations (County Regulation(s)). construction or use of the structure(s) and facility(ies), described above, I hereby grant permission to the Building Department to enter the property, Building Official from: (1) requiring the correction of errors in the submittals, of County Regulation(s) or any other applicable law. Review of this Application, including submittals, and inspections of the or discrepancies. As the Owner, I acknowledge that responsibility for limitation my architect designer, engineer and/ or builder. 1 HEREBY ACKNOWLEDGE THAT I H • , RE . e AND UNDERSTAND / OWNERS SIGNATU' ATE j�lC�tl' -1p-1 Lfl Gam} _rci ti j (x.11 STAFF USE ONLY CA' 4 7 6v2.. $5 Special Conditions: Adjusted Valuation: 3,5 l i B. 6 0 Plan Check Fee: 3 z 1d . S 3 Permit Fee: 50Z. 35' Manu home Fee: Misc Fees: 4E08 Fee: Total Fees: Fees Paid: Balance Due: 13P No & Issue Date: ISDS No & Issued Date: 8z9&9 3)49.53 Sd2.3,Rff-lciTS wiA Setbacks:"( ! F Z,> / 1z z5, 5 10 OCC Group: KL..Tec, Const Type: 'Zoning: BLDG DEPT: x‘.,e_e&I;.-04 .0.// PLNG DEPT: 4t-pA4A.4-3 3A5/// APPROVAL DATE APPROVAL DATE The following items are required by Garfield County for a final Inspection: 1) A final Electrical Inspection from the Colorado State Electrical Inspector. lY 6_ 2) Permanent address assigned by Garfield County Building Department and posted at the 6 structure and where readily visible from access road. �fl 3) A finished roof; a lockable building; completed exterior siding; exterior doors and windows installed; a complete kitchen with cabinets, sink with hot & cold running water, non-absorbent kitchen floor covering, counter tops and finished walls, ready for stove and refrigerator; all necessary plumbing. 4) All bathrooms must be complete, with washbowl, tub or shower, toilet, hot and cold running water, non-absorbent floors, walls finished, and privacy door. 5) Steps over three (3) risers, outside or inside must be must have handrails. Balconies and decks over 30" high must be constructed to all IBC and IRC requirements including guardrails. 6) Outside grading completed so that water slopes away from the building; 7) Exceptions to the outside steps, decks, grading may be made upon the demonstration of extenuating circumstances., i.e. weather. Under such circumstances A Certificate of Occupancy may be issued conditionally. A final inspection sign off by the Garfield County Road & Bridge Department for driveway installation, where applicable; as well as any final sign off by the Fire District, and/or State Agencies where applicable. A CERTIFICATE OF OCCUPANCY (C.O.) WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. A C.O. MAY TAKE UP TO 5 BUSINESS DAYS TO BE PROCESSED AND ISSUED. OWNER CANNOT OCCUPY OR USE DWELLING UNTIL A C.O. IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. I understand and agree to abide by the above conditions for occupancy, use and the issuance of a C.O. for the building identified in the Building Permit. OWNERS SIGNATURE DAT r B app Iicationdecember2007 Building Plan Review Description of Work: Add a mud room Bin #: Location Address: 1416 CR 132 GLENWOOD SPRINGS, CO General Information Case Manager: David Bartholomew Plan Case Number: BLDG -3-11-6763 Parcel: 211934200033 Application Date: 03/10/2011 Contacts Owner: Owen Minney Applicant: Owen Minney Applicant Phone: Email: Building ( Engineered Foundation N/4 Driveway Permit Surveyed Site Plan Planning/Zoning Property Line Setbacks 30ft Stream Setbacks Flood Plain / Septic Permit and Setbacks / Building height Grade/Topography 30% / Toning Sign -off Attach Residential Plan Review List AP Road Impact Fees / Minimum Application Questionnare /`'%✓9 HOA/DRC Approval NA' Subdivision Plat Notes , Grade/Topography 40% AM Fire Department Review 7 Planning Issues / Valuation Determination/Fees Subdivision Plat Red Line Plans/Stamps/Sticker General Comments: Attach Conditions Application Signed Plan Reviewer To Sign Application Parcel/Schedule No. A*4 40# Snowload Letter - Manu. Homes ��� Soils Report Applicant Address Date VALUATION FEE DETERMINATION Owen Minney 1416 CR 132 GWS 3/15/2011 Subdivision Lot/Block Contractor Finished (Livable Area): Main 301 sq.ft Upper sq.ft Lower sq.ft Other sq.ft X $74.68 Total Square Feet 301 sq.ft Valuation Basement: Unfinished Conversion of Unfinished to Finished Total Valuation Garage/Storage (wood framed) Carport: Total Valuation Crawl Space Total Valuation Decks/ Patios/Porches Covered Open Total Valuation Type of Construction: Occupancy: Valuation 319 104 sq.ft X $41.00 sq.ft X $33.68 sq.ft X $18.00 sq.ft X $12.00 sq.ft X $9.00 sq.ft X $24.00 sq.ftX $12.00 Commercial sf X sf X sf X sf X sf X sf X N/A N/A Owner 22,478.68 10,743.92 0.00 0.00 2,496.00 0.00 Total Valuation 35,718.60 Applicant: Job Address: Subd- Lot/block: FEE. ESTIMATE FOR S/F STICK BUILT HOMES (ALL FEES ARE ESTIMATES UNTIL FINAL PLANS ARE REVIEWED) G(J--- t o_e; /11/`% 2,f% 45gri?NT INISHED LIVING SPACE: sf X 74.68= 2-, (/ 8. g UNFINISHED BASEMENT: sf X 41.00= CRAWL SPACE: - sf X 9.00= GARAGE: sf X 18.00= UNCOVERED PATIO/DECK: sf X 12.00= COVERED PATIO/DECK 6/4,eH —L eY510 3j j ( 33,6 S ) a/ '7113, 9 z. IISC: MISC: /07 sf X 24.00= Z/ L 9k, TOTAL VALUATION: 35 -7) 8 hU THIS SECTION WILL BE DETERMEND BY GARFIELD COUNTY BUILDING & PLANNING PLAN REVIEW FEE: PERMIT FEE: TOTAL: so Z • SLS 92 8.88 SEPTIC= PERMIT: PERC: 0314 ( m - LJ ,y /l7 /Y/y /4-//‘, cg, / 3 7. �'� iy cvg)v.e).y� S F W,/-5 S` /y7 >13/A77 - 0A7 ✓ i2.7� Q % ri-F/ Ae_ P f/ c `/ Cze, ,, % f c_ g Re-glo 12,0 //).-67 L / / 7 ivp 1/6, .5 f7t2&-e-17`79 h9/ % c/ r2 `r�'®, C /4/6/6' ci aole GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS For SINGLE FAMILY DWELLING CONSTRUCTION Including NEW CONSTRUCTION ADDITIONS ALTERATIONS And MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. When reviewing a plan and it's discovered that required information has not been provided by the applicant, this will result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor shall be required to provide this information before the plan review can proceed. Other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. TWO (2) SETS OF CONSTRUCTION DRAWINGS & TWO (2) SITE PLANS MUST BE SUBMITTEDFOR ALL APPLICATIONS. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. Any project with more than ten (10) occupants requires the plans to be sealed by a Colorado Registered Design Professional. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following checklist prior to and during design. Applicants are required to indicate appropriately and to submit the completed checklist at time of application for a permit. Plans to be included for a Building Permit, must be on drafting paper at least 18"x24" and drawn to scale. Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks, balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line and 1 original grade. A section showing in detail, from the bottom of the footing to the top of the roof, including re -bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house -rap, (which is required), siding or any approved building material. Engineered foundations may be required. A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. wind speed, wind exposure B or C, and a 36 inch frost depth. All sheets to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be in compliance with the 2009 IRC, and 2009 IECC. 1 Is a site plan included that identifies the location of the proposed structure or addition and distances to the property lines from each corner of the proposed structure(s) prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Properties with slopes of 30% or greater must be shown on the site plan. (NOTE Section: 106.2) Any site plan for the placement of any portion of a structure within 50 ft. of a property line and not within a previously surveyed building envelope on a subdivision final plat shall be prepared by a licensed surveyor and have the surveyor's signature and professional stamp on the drawing. Any structure to be built within a building envelope of a lot shown on a recorded subdivision plat shall include a copy of the building envelope as it is shown on the final plat with the proposed structure located withi a envelope. Yes 2. Does the site plan also include any other buildings on the property, setback easements and utility easements? Please refer to Section 3-301 in the Garfield County Zoning Resolution if the property you are applying for a building permit on is located on a corner lot. Special setbacks do apply. Yes_,_ 3. Does the site plan include when applicable the location of the I.S.D.S. (Individual Sewage Disposal System) and the distances to the property lines, wells (on subject property and adjacent prope�t�jies), streams or water courses? Yes l( 4. Does the site plan indicate the location and direction of the County or private road accessing the property; Yes X 5. Have you provided any RESOLUTIONS and/ or LAND USE PERMIT(S) associated with this property? Yes if Yes please provide a COPY. No 2 6. Are you aware that prior to submittal of a building permit application you are required to show proof of a legal and adequate access to the site? This may include (but is not limited to) proof of your right to use a private easement/right of way; A County Road and Bridge permit; a Colorado Dept. of Highway Permit, including a Notice to Proceed; a permit from the federal government or any combination. You can contact the Road & Bridge Department at 625-8601. See phone book for other xncies Yes 7. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accofylance with the IRC or per stamped engineered design? Yes J� 8. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances/required between wood and earth? Yes A No 9. Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces and soffits? Yes X No 10. Do the plans include design loads as required by Garfield County for roof snow loads, (a minimum of 40 pounds per square foot up to & including 7,000 feet above sea level), floor loads and wind loads? Yes 11. Does the plan include a building section drawing indicating foundation, wall, floor, and roof constru tion? Yes 12. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof ra tars or joists or trusses? Yes f ' 13. Does the building section drawing or other detail include the method of positive connection of all columns d beams? Yes 14. Does the elevation plan indicate the height of the building or proposed addition from the undisturbed grade to the midpoint between the ridge and eave of a gable or shed roof or the top of a flat_rpof? (Building height measurement usually not to exceed 25 feet) Yes 7\ 15. Does the plan include any stove or zero clearance fireplace planned for installation including make an. ' ..:1 and Colorado Phase 1;1 certifications or phase II EPA certification? Yeses No 1 3 16. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the IRC? ` n Yes No x 17. Does the plan include a window schedule or other verification that egress/rescue windows from sleepin ooms and/or basements comply with the requirements of the IRC? Yes 18. Does the plan include a window schedule or other verification that windows provide natural light and ventilatgn for all habitable rooms? Yes n 19. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety glazing for these areas? 4 j Yes No IV 20. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan?,�` Yes n 21. Do you understand that if you are building on a parcel of land created by the exemption process or the subdivi ion process, are building plans in compliance with all plat notes and/or covenants? Yes 22. Do you understand that if you belong to a Homeowners Association (HOA), it is your responsibility to obtain written permission from the association, if required by that association, prior to submitting an application for a building permit? The building permit application will be accepted without it, but you run the risk of the HOA bringing action to enforce the covenants, which can result in revocation of permit issued. Additionally, your Plan Review fee is not refundable if the plans have been reviewed by the Building Department prior to any action by the HOA that requires either revocafi t su. tantial modification of the plans. Yes 1 23. Will this be th only residential structure on the parcel? Yes No If no -Explain: 24. Have two 2 complete sets of construction drawings been submitted with the application? Yes 25. Do you u Yes rstand that the minimum dimension a home can be on a lot is 20ft.wide and 20ft. long? 4 26. Have you designed or had this plan designed while considering building and other construction code require r lts? Yes nn 27. Do your plans comply with all zoning rules and regulations in the County related to your properties zone di�trrct? Yes Gx� 28. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by the rfield County Building Department? Yes 29. Do you understand that approval for design and/or construction changes are required prior to the applicaii► of these changes? Yes /\ 30. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application submittal and that you will be required to pay the "Permit Fee" as well as any "Road Iact" or "Septic System" fees required, at the time you pick up your building permit? Yes 31. Are you aware that you must call in for an inspection by 3:30 the business day before the requested inspection in order to receive it the following business day? Inspections will be made from 7:30 a.m. to 3:30 p.m. Monday through Friday. Inspections are to be called in to 888-8 f 8-5306. Yes 2 No 32. Are you aware that requesting inspections on work that is not ready or not accessible will result in a $50.00 re-ir}spection fee? Yes x 33. Are you aware that you are required to call for all inspections required under the IRC including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of the buildi��? Yes JJ�� 34. Are you aware that the Permit Application must be signed by the Owner or a written authority being given ftan Agent and that the party responsible for the project must comply with the IRC? Yes 5 35. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups, unless you as the homeowner are performing the work? The license number of the person performing the work will be required at time of applicabinspection. Yes 36. Are you aware, that on the front of the Building Permit Application you will need to fill in the Parcel/Schedule Number for the lot you are applying for this permit on prior to submittal of a building p rmit application? Your attention in this is appreciated. Yes 37. Do you know that the local fire district may require you to submit plans for their review of fire safety issues? Yes (please check with the building department about this requirement) 38. Do you understand that if you are planning on doing any excavating or grading to the property prior to iss ce of a building permit that you will be required to obtain a grading permit? Yes? 39. Are you aware that if you will be connecting to a public water and/or sewer system, that the tap fees have to be pai and the connections inspected by the service provider prior to the issuance of a Certi to of ccupancy? Yes o1% 40. If you anticipate dbtaining a water tap from the City of Rifle, please provide a letter indicating that the City will provide water service. No building permit application will be accepted without such a letter. Yes I hereb acknowledge that I have read, understand and answered these questions to the best of my a ature of Owner q7 -o 'i;;- 2 q1� Phone:g49' 1,e-s-1(days); (V/I/ Date e1 --0 �y5 ,? ') (evenings) Project Name: J/%ChtzC< eik. i%lhWy / ' '✓C'L 460—ON Project Address: i7 /( eL ,1 Z 1??&A s �p c&6c!/ 6 Notes: If any required information is missing delays in issuing the permit are to be expected. Work may not proceed without the issuance of a permit. If it is determined by the Building Official that additional information is necessary to review the application and plans to determine minimum compliance with the adopted codes, the application may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review, delay in issuance of the pennit or delay in proceeding with construction. bpminregsfJun2010 7 This does not constitute a building or use permit. GARFIELD COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH 2014 Blake Avenue Glenwood Springs, Colorado 81601 REPAIR & ALTERATION - NO CHARGE Phone 13031946.7266 INDIVIDUAL SEWAGE DISPOSAL PERMIT NY 921, Owner Earl Warren System Location`/ 1416 County Roadad132 - Mitchell Creek Licensed Contractor Cs-F� K o / ' Conditional Construction approval is herebyrerented fora 'J o gallon -( Septic Tank or Aerated treatment unit. Absorption area for dispersal area) computed es follows: . Pero rate of one inch in _Si_ minutes requires a minimum of ., b sq. ft. of absorption area per bedroom. Therefore the no. of bedrooms , x 1a f sq ft. minimum requirement - a total of 2 ft of absorption area. May we suggest / R )C ;2.1 X 3 Date '/ P1 FINAL APPROVAL OF SYSTEM: Inspector No system shall be deemed to be in compliance with the Sewage Disposal Laws until the assembled system Is approved prior to cover- ing any part. Septic Tank access for inspection and cleaning witliln 12" of ground surface or Berated access ports above ground surface. Proper meter' Is and a e bly.Oac 0 Tr me of septi or Ger ed Ohl uiflt. " 6# 7 &J � OAC //ie/J * OA. a..4% ////L 19 ie< Ort vK Adequate absorption (or dispersal) area. Adequate compliance with permit requirements. Adequate compliance with County and State regulations/requirements. Othe Date / 05 y 0 - Inspecto RETAIN WITH RECEIPT RECORD* CONSTRUCTION SITE up, MWier • `CONDITIONS: Page Two INDIVIDUAL HOME SEWAGE TREATMENT SYSTEMS APPLICATION 1' Owner: (41.4.4(2 / 42.44.2a -c. Y -ufrTce use Fees Paid $ Date II —.3—Sa Mail Address:an_43" C1ty:t/t_,,,1n._41g9 Zip: INFORMATION REGARDING PROJECT SUBMITTED FOR REVIEW Attach separate sheets or report showing'entire area with respect to surrounding areas, topography of area, habitable buildings, location of potable water wells, soil percola- tion test holes, soil profiles in test holes (see Page 3). Near What , 1. Location of Facility: County GARFIELD City or Town�Q,�Q $/9,,e.,,1J LegaliDescription&/or b ).ot Size A-vwo 2. No. of Bedrooms 72, Septic Tank. Capacity 74-6 Aeration Unit Capacity N/A 3. Source of Domestic Water: Public (name): Ci,p' ` )Naiir, :f/6a( Phone :r .Sell&4 Private: Well Depth Other Depth to 1st ground water table 4. Is facility within boundaries of a city/town or sanitation district? - 5. Distance to nearest sewer system: Are-. ice Have you attempted to arrange a connection with the system? —y�.- If rejected, what was the reason? 6. If R.P.E. tested, state rate of absorption in test holes shown on the location map, minutes per inch of drop in water level after holes have been soaked for 24 hours: in 7. Name, address, and telephone of R.P.E. who made soil absorption tests: 8. Name, address, and telephone of R:P.E. responsible for design of the system: 9. Express permission is hereby granted for the inspection of the above property by any member of the Garfield County Building & Sanitation Department and/or such persons as they may designate, Any withdrawal of this permission shall be in writing and receipt acknowledged by the County Building & Sanitation Department. 10. I have been given an opportunity to read the Individual Sewage Disposal Systems Regula- tions of Garfield County and 1 hereby agree to comply with all terms, conditions and requirements included therein. 77.' d Date /9 fQ Signature of Applicant (TO BE RETURNED TO BLDG. & SAN1. DEPT.) 4/ PLEASE DRAW AN ACCURATE MAP TO YOUR PROPERTY Page Three INDICATE BELOW THE LOCATION OF YOUR BUILDINGS WATER SUPPLY AND DISTRI- BUTION LINES, STREAMS, IRRIGATION DITCHES, ROADWAYS, AND BOUNDARY LINES (TO BE RETURNED TO BLDG. & SANI. DEPT.)