Loading...
HomeMy WebLinkAboutPlans.pdft), 1/41 , 1 N •• . --.11 O! ?/ L d V ,...q $CIaVMt bnd "','d ri nxx.� ��k:w,�c� p ��ff FY ��hh qee,,p .. {. i.� aJ...)b`,`.d"�1� Nd�� �r'.'�ir t;•':�.� d1f5i1 VAN4 << 69 d lr'C"}t' rddo , •':iGY43V e 470 • 4 Mi A rot zera9 z-gc, R3/ 5. '-e1) ....V. •.:1-. ---r, •_•%, ..3— 4 Q..) .4 () ct, t..i... ,c----) beb --f-- "V) -1\ *or tJ r - Single Family Residential Uncovered Decks and Porches Directions 1. Fill in the blanks. Please print legibly. 2. Indicate in the check box which detail from page 3 will be used. Size and1Amount of Lags/, Ti-t.a 5 L t e. JBcks 3Z (jam, (example: Two 1/2'x4 lags CO 16"0.0.) Deck Section Address: 5/18/10 A+fr/.he.,,r C>e-e/ T:4)/ PA.rI,c�,.tc LO 4,3S Type of decking 1 x 6 - Cvpnpas: re (example: 1 x 4 or2x 6 - Trex) Existing bldg. Electrical outlet required on decks over 20 sq. ft. Approved flashing required 36" high guard with balusters spaced so that a 4 Inch diameter sphere cannot pass through Beam splices to occur over posts with 1 1/2" bearing Attach decking with non corrosive fasteners E m 0 CD 2x X joists spaced / 6 " apart (example: 2 x 10" spaced 24' apart) (Z) 2, x Y beam (example: (2)2 x 10 - see detail B) Detail A (see page 3) • 2x 7 rim joist (example: 2x 10- see Alternate B18 82) ❑ Detail B O Alternate Detail 81 ❑ Alternate Detail 82 (see page 3) Conditions such as attachment to cantilevers or veneers may require Engineer's approval Span ( t1 x 4l posts spaced 7 " apart l(example: 4 x 4 posts spaced 8' apart) Finished grade Dil C ,.., (see pageeta3)�Tts• Note: Emergency escape windows are allowed to be installed under decks and porches provided the location of the deck allows the emergency escape window to be fully opened and provides a path not less than 36" in height to a yard or court. 6'8" required for walk out basements or patios. 36 Inches Min. Type of siding (existing) Note: A plot plan (plan view) showing the dimensions of your project or additions and its relationships to existing buildings or structures on the property must be included. In addition to project dimensions, your plot plan must also show other details such as post locations and spacing, joist and beam spans, and any other pertinent information not shown on the section drawing. This handout was developed by the Colorado Chapter of the International Code Council as a basic plan submittal under the 2009 International Residential Code. It is not intended to cover all circumstances. Check with your Department of Building Safety for additional requirements.