HomeMy WebLinkAbout2.0 Staff ReportREOUEST:
• •
BOCC 2/18/97
PROJECT INFORMATION AND STAFF COMMENTS
Floodplain Special Use Permit and Amended
Final Plat, Lots 1 & 2, Block 7, Rifle Village
South Subdivision.
APPLICANT: Laurence Bradley
LOCATION:
Lots 1 & 2, Block 7, Rifle Village South
Subdivision; located approximately one (1)
mile southwest of Rifle.
SITE DATA: Approximately 13,000 square feet
WATER: City of Rifle
SEWER: City of Rifle
ACCESS: Direct from Shotgun Street/Colt Drive
EXISTING ZONING: R/L/UD
ADJACENT ZONING: R/L/UD
I. RELATIONSHIP TO THE COMPREHENSIVE PLAN
The subject property is located in District A - Subdivisions, according to the Garfield County
Comprehensive Plan's Management Districts Map (1981; 1984).
II. DESCRIPTION OF THE PROPOSAL
A. Site Description: The subject property is approximately 13,000 square feet in size,
located in the Rifle Village South subdivision, one (1) mile southwest of the City of
Rifle. The property is currently undeveloped and in native vegetation. There are a
number of existing, single family dwellings throughout the subdivision. The tract
exists on the alluvial fan created at the mouth of Helmer Gulch, which has been
identified by the Federal Emergency Management Agency as a special type of flood
hazard. See vicinity map, page •
• •
B. Adjacent Land Uses: Land uses adjacent to the subject property are limited to single
family residential.
C. Development Proposal. The applicants are proposing the construction of a new,
single family dwelling on land that has been identified as existing within floodplain
zone AO, a special flood hazard area that can be inundated by types of 100 -year
shallow flooding where depths are one (1) foot or Tess with associated velocities of
four (4) feet per second, therefore, requiring the issuance of a Floodplain Special Use
Permit pursuant to Section 6:00 of the Garfield County Zoning Resolution.
Additionally, the applicant is requesting an amendment to the Rifle Village South
Subdivision Final Plat to merge Tots 1 & 2, Block 7. See site map, page 7•
III. MAJOR ISSUES AND CONCERNS
A. Floodplain: The subject tract of land is located within the "mapped" 100 -year
floodplain of Helmer Gulch. In order to meet County zoning requirements, it is
required that a Colorado registered professional engineer certify that the house will
be built in such a manner that it would withstand expected hydrostatic, hydrodynamic
and buoyant forces imposed upon the house in the event of a 100 -year flood.
Section 6:00 of the Zoning Resolution requires an approved Special Use Permit for
any development within a regulated (mapped) floodplain. The purpose of the Special
Use Permit review is to assure compliance with various applicable state and federal
regulations, as well as reviewing relevant technical data.
B. Building Design: Pursuant to Section 6:09:02 of the Zoning Resolution, the
construction of a new or substantially improved structure must meet certain
performance standards to have a reasonable assurance that the proposed construction
will be safe from flooding, to wit:
The lowest floor, including basement, of any new or substantially improved building
designed for residential occupancy shall not be Tess than one (1) foot above the
maximum water elevation of the 100 -year flood;
All new construction shall be reasonably safe from flooding;
All new construction shall be designed and adequately anchored to prevent flotation,
collapse or lateral movement, be constructed with materials and utility equipment
resistant to flood damage, and be constructed by methods that minimize flood
damage;
Within any area subject to sheet flow (Zone AO on the Flood Insurance Rate Maps)
all new construction and substantial improvements of residential structures shall have
the lowest floor, including basement, elevated above the highest adjacent grade of the
nearest street to or above the depth number specified on the Flood Maps.
C. Engineering: The applicant has engaged Jerome Gamba & Associates to conduct an
engineering review and certify that the construction will occur pursuant to the above
requirements. Mike Gamba has evaluated the property and has submitted the
following findings:
1. The 100 -year flood event from Helmer Gulch has been calculated to be on the
magnitude of 760 cubic feet per second (cfs).
2. Based on the flood depth of flow of one (1) foot, the 760 cfs flood flow
would have a total width of approximately 217 feet or 6% of the 3600 foot
width of the alluvial fan floodplain.
3. Using these calculations, it is possible to estimate the average probability of
any individual house being affected by this type of flooding, essentially
resulting in an occurrence of once every 1667 years.
4. The hydraulic capacity of Colt Drive indicates a required flow depth of 1.54
feet in order to discharge a flow of 760 cfs.
Based on these findings, Gamba can provide certification that the home is constructed
to meet requirements and be "reasonably safe from flooding," given the following
conditions of construction:
I . That the minimum, finished floor elevation of the residence shall be no less
than 5324.2 feet.
2. The foundation shall be cast -in-place reinforced concrete footers and stem
walls and all foundation designs should be based on site specific geotechnical
soil and foundation investigations.
3. That site grading around the perimeter of the residence be such that there is
a minimum grade of 10% for a minimum distance of 10 feet and all patios,
driveways and sidewalks slope away from the house at a minimum grade of
2%. Beyond these features, the 10%/10 foot grade shall be continued.
4. All foundation construction shalLcorn& with Uniform Building Code criteria.
(See engineer's letter, pages r 17
Consistent with FEMA requirements, certified "as-builts" and an elevation certificate
for the finished floor elevation must be conditions of approval.
D. Soils: Hepworth-Pawlak Geotechnical has provided a subsoil study report detailing
the type of soil encountered in a test bore hole. Based on this evaluation, the soils are
considered low-density and hydrocompressive and footings placed on the undisturbed
natural soils should be designed for a soil bearing pressure of 1000 psf. The report
• •
makes additional recommendations on foundation design and construction, which
should b� followed, based on the exact type of foundation to be used. See report,
pagesCw
E. Amended Final Plat: The floodplain special use permit application is being combined
with an application for amended final plat of Lots 1 & 2, Block 7, Rifle Village South
Subdivision. Given the original platting of the Subdivision lots, owners have found
it very difficult to construct residences and accessory buildings and still comply with
mandatory setbacks. This amended final plat request would erase the line between the
two (2) subject lots and create one (1) new lot that would comply with all applicable
setbacks. As far as this portion of the application is conte ned, a conceptual approval
from the Board is all that is required. See map, page :
IV. SUGGESTED FINDINGS
1. That proper publication and public notice was provided as required by law for the
hearing before the Board of County Commissioners.
2, That the hearing before the Board of County Commissioners was extensive and
complete, that all pertinent facts, matters and issues were submitted and that all
interested parties were heard at that hearing.
3, That the application is in compliance with the Garfield County Zoning Resolution of
1978, as amended.
4. For the above stated and other reasons, the proposed use is in the best interest of the
health, safety, morals, convenience, order, prosperity and welfare of the citizens of
Garfield County.
V. RECOMMENDATION
Staff recommends APPROVAL of the Floodplain Special Use Permit, pursuant to the
following conditions:
1. That all representations by the applicant made before the Board of County
Commissioners shall be conditions of approval, unless otherwise stated.
2. That the minimum, finished floor elevation of the residence shall be no less than
5324.2 feet.
3. The foundation shall be cast -in-place reinforced concrete footers and stem walls and
all foundation designs should be based on the site specific geotechnical soil and
foundation investigations.
4. That site grading around the perimeter of the residence be such that there is a
minimum grade of 10% for a minimum distance of 10 feet and all patios, driveways
and sidewalks slope away from the house at a minimum grade of 2%. Beyond these
features, the 10%/10 foot grade shall be continued.
5. All foundation construction shall comply with the 1994 Uniform Building Code, as
adopted by Garfield County.
6. Prior to the approval of a final/certificate of occupancy for the residence, the property
owner shall submit an elevation certificate, signed and stamped by a licensed land
surveyor, for the finished floor elevation of the single family dwelling unit.
�- INiv bitSYivcr 5 94,461.13(c
/qvEp
2/fi-o/ 1