Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Application - Permit
'Garfield County .. N~-~0294 ____ ·~ Building & Sanitation Department 108 8th Street, Suite #401 Glenwood Springs, Co. 81601 Office-945-8212 Inspection Line-384-5003 Job Address r; ~ 0 -r-a:~M}-~Y fJv'f.._ t~ (1 f? (~,c;() NatureofWork Building Permit · ;,~R__..r::J~ ,;/.(',l/7-09J-00 -D/7 U f B ~· I) '-fJ-. n ·)(.__ Zf ' ~ . se o u~) :ng , CAL~~~k T vv ---<:'(3><: - Owner f -~ , [~~ D , I ~ Contractor t~b~ ~.QA_,~~ Amount of Permit $ C[ (o :l · .)... 0 Date ~q~ o2DD7 ;r;) ?' " ' Cle;k L '. ~9-, ( c ' 1 2 3 4 5 6 7 8 9 10 GARFIELD COUNTY BUILDING PERMIT APPLICATION 108 s~· Street, SUite 401, Glea.wood Sprl.a.gs, CO 81601 / /)"'i·o/r·•2t2 1 Fwc o7o.as+a47o 1 , ......... Lln•• 970-a84-sooa Permit No'~ Parcel/Schedule No'J./7'709)00(17? I Job Address: 7~o fAlfiJtw Av<e_ -p; t..c::'le . tt G. su LotNq Block No: Subd. I Exemption: OwnK:;;:I-), f>e lrC:.t' Address Ph: w~~~'?-"l"tc 7'l>o FAir!-IAv 1.1.~._ t.~s-~'1' 7 .L '( '(<T~tl2 Address: Ph: Lie. No. kevf>fef' Architect/ Engineer: Address: Ph' Lie. No. Sq. Ft. of Building: ;).ljOQ Sq. Ft of Los. tJ t::ft!5 Height: ~0 No. ofrloors: Use of Building: (;Ar99.::. Descnbe Work: C.o-v $/rvc.f. 'f£:2Ji''·····,··.···.···.·_, ...•... :·:·· ···::·····.····· N<w e:..Mc!.i..:.L '4ArA9'tf Class of Work: ~ NeW'_,, ____ 0 Alteration o Remove 0 Addition 0 Move Garage: 0 Single Carport: 0 Single 0 Double u Double NP ..-.., t'few.!J<Pe.Tt-, 1/..J.. 0 OnMSite Sewage % Site Plan Disposal 1-1 11 Valuation of Work:(!; 3o,ooo Adjusted Valuations' fl' ..Lj 'j Z()tJ !!!2- 12 Special Conditions: NOTICE 1%;-;~ ~qit/3'to-A SEPARATE ELECTRICAL PERMIT IS REQUIRED AND MUST BE ISSUED BY THE STATE OF COI..ORADO. THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION ~96~~ Dated Permit Issued: AUTHORIZED IS NOf COMMENCED WITHLN 180 DAYS, OR, IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AF'l'ER WORK IS COMMENCED. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS oc?Jt!!: Const. Type: APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS GOVERNING THIS TYPE OF WORK WILL BE COMPLETED WITHIN WHETHER SPECIFIED HEREIN OR NOT. THE Zdning: Setbacks: GRANTING OF A PERMIT DOES NOf PRESUME TO GIVE AUTHORI'rY TO VIOLATE OR 'CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION . ..4/~ J:;J.-1-o'-Manu. Home: ISDS No. & Fee: SIGNEJ'UR'E ~ DATE 7A ~ ·3'rJ7~-.,\t'""-' ,,; lf-C>7 13LDG D~:.r: 'W ./ PLNG.DEEh. APPROVAL DATE APPROVAL DATE AGREEMENT PERMISSION IS HEREBY GRANTED TO THE APPLICANT AS OWNER, CONTRACTOR AND/OR THE AGENT OF THE CONTRACTOR OR OWNER TO CONSTRUCT THE STRUCTURE AS DETAILED ON PLANS AND SPECIF1CATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT. IN CONSIDERATION OF THE ISSSUANCE OF THIS PERMIT, THE SIGNER. HEREBY AGREES TO COMPLY Wl1'H ALL BUILDING CODES AND LAND USE REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN LN 30.28.201 CRS AS AMENDED. THE SIGN&R FURTHER AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPILED WITH IN THE LCOATION, ERECTION, CONSTRUCTION, AND USE OF THE ABOVE DESCRIBED STRUCTURE, THE PERMIT MAY BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT SHAI..I. BECOME NULL AND VOID. THE ISSUANCE OF A PERMT BASED UPON PLANS, SPECIFICATIONS AND Ol'HER DATA SHALL NOf PREVENT THE BUILDING OFFICIAL FROM THEREAFI'ER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OfHER DATA OR FROM PREVENTING BUILDING OPERATION BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OFTHS CODE OR ANY OI'HER ORDINANCE OR REGULATION OF THIS JURISDICTION. THE REVIEW OF SUBMI'ITED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAF'l'ER DOES NOT CONSTITUTE AN ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABI.JTIES BY GARFIELD COUNTY FOR ERRORS, OMISSIONS OR DISCREPENCIES. THE RESFONSI BILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICJALLY WITH THE ART!CTECT, DESIGNER, BUILDER, AND OWNER COMMENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS LNTEREST. c-~_D ~ d $ :s-7 0.E~;:LEDGt:h4t R~;~:STANDTHE AGREEMENT ABOVE(IffiTIAL) ~---- 1 ;)-I \:-O[p vt\)4\1 The following items are required by Garfield County for a final inspection: 1. A final Electrical Inspection from the Colorado State Electrical Inspector; 2. Permanent address assigned by Garfield County Building Department posted where readily visible from access road; 3. A finished roof, a lockable house, complete exterior siding, exterior doors and windows installed, a complete kitchen with cabinets, a sink with hot & cold running water, non-absorbent kitchen floor coverings, counter tops and finished walls, ready for stove and refrigerator, all necessary plumbing; 4. All bathrooms must be complete, with washbowl, tub or shower, toilet stool, hot and cold running water, non-absorbent floors and walls finished and a privacy door; 5. All steps outside or inside over three (3) steps must have handrails, guard rails on balconies or decks over 30" high constructed to all IBC and IRC requirements; 6. Outside grading done to where water will detour away from the bnilding; 7. Exceptions to the outside steps, decks and grading may be made upon the demonstration of extenuating circumstances, i.e. weather, but a Certificate of Occupancy will not be issued until all the required items are completed and a final inspection made; 8. A final inspection sign off by the Garfield County Road & Bridge Department for driveway installation, where applicable; as well as any final sign off by the Fire District, and/or State Agencies where applicable. 9. If you will be connecting to a public water and/or sewer system, proof of the tap fees have been paid and the connections inspected by the service provider prior to issuance of a C.O. A CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. ****A CERTIFICATE OF OCCUPANCY MAY TAKE UP TO 5 BUSINESS DAYS TO BE PROCESSED AND ISSUED. ****CANNOT OCCUPY OR USE DWELLING UNTIL A CERTIFICATE OF OCCUPANCY (C.O.) IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. I understand and agree to abide by the above conditions for occupancy, us~ and the issuance of a Certificate of Occupancy for the dwelling under building permit # /6, CJL( I ~-· Signature Bpapplicationoctober2006 t&-(-ob Date VALUATION/FEE DETERMINATION Applicant /J:-itzRcr Address 7B'cJPrH!l oJtkf 1/tJ'f Date I" 3 va7 Finished (Livable Area): Ma:in Upper Lower Other Basement: Total Square Feet Valuation Unfinished Conversion ofUnfmished to Finished Plan Check Fee for Conversion Valuation Garage: ,::2-L/(){) K troo J Jf 3 z_ooa:L Valuation 1 Crawl Space: Valuation Decks/Patios: Covered Valuation Open Valuation Total Valuatiot-.; 31 ~ 0 "' Subdivision Lot/Block Cj Contractor fJ K '\· %.-Sffi GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS For SINGLE FAMILY DWELLING CONSTRUCTION Including NEW CONSTRUCTION ADDITIONS ALTERATIONS And MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. When reviewing a plan and it's discovered that required information has not been provided by the applicant, this will result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor shall be required to provide this information before the plan review can proceed. Other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. Any project with more than ten (10) occupants requires the plans to be sealed by a Colorado Registered Design Professional. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following checklist prior to and during design. Applicants are required to indicate appropriately and to submit the completed checklist at time of application for a permit. Plans to be included for a Building Permit, must be on drafting paper at least 18"x24" and drawn to scale. I Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks, balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line and original grade. A section showing in detail, from the bottom of the footing to the top of the roof, including re-bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house-rap, (which is required), siding or any approved building material. Engineered foundations may be required. A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. wind speed, wind exposure B or C, and a 36 inch frost depth. All sheets to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be incompliance with the 2003 IRC. 1. Is a site plan included that identifies the location of the proposed structure or addition and distances to the property lines from each comer of the proposed structure(s) prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Properties with slopes of 30% or greater must be shown on the site plan. (NOTE Section: 106.2) Any site plan for the placement of any portion of a structure within 50 ft. of a property line and not within a previously surveyed building envelope on a subdivision final plat shall be prepared by a licensed surveyor and have the surveyor's signature and professional stamp on the drawing. Any structure to be built within a building envelope of a lot shown on a recorded subdivision plat shall include a copy of the building envelope as it is shown on the final plat with the proposed structure located within th_y-envelope. Yes V ---"--- 2. Does the site plan also include any other buildings on the property, setback easements and utility easements? Please refer to Section 5.05.03 in the Garfield County Zoning Resolution if the property you are applying for a building permit on is located on a corner lot. Special setback~ apply. Yes ___ _ 3. Does the site plan include when applicable the location of the I.S.D.S. (Individual Sewage Disposal System) and the distances to the property lines, wells (on subject property and adjacent properties), streams or water courses? Yes Nih I 4. Does the site plan indicate the location and direction of the County or private road accessing 2 the propert~ Yes ____ _ 5. Are you aware that prior to submittal of a building permit application you are required to show proof of a driveway access permit or obtain a statement from the Garfield County Road & Bridge Department stating one is not necessary? You can contact the Road & Bridge Department at 625-8601. Yes 6/A 6. Do the plans include a foundation plan indicating the size. location and spacing of all reinforcing~! in accordance with the IRC or per stamped engineered design? Yes. ____ _ 7. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and earth? Yes "- 8. Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces and s~? Yes _____ _ 9. Do the plans include design loads as required by Garfield County for roof snow loads, (a minimum of 40 pounds per square foot up to & including 7,000 feet above sea level), floor loads and wind lo)lds? Yes (/ 10. Does the plan ~de a building section drawing indicating foundation, wall, floor, and roof construction? ~ Yes ______ _ 11. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters oY.foists or trusses? Yes. ____ -"'V'--- 12. Does the building section drawing or other detail include the method of positive connection of all columns and b~? Yes ______ _ 13. Does the elevation plan indicate the height of the building or proposed addition from the undisturbed grade to the midpoint between the ridge and eave of a gable or shed roof or the top of a flat roof_/(Building height measurement usually not to exceed 25 feet) Yes · 3 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase .:a-certifications or phase ll EPA certification? Yes No V . Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the IRC? / Yes No ____________ __ Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements comply with the requirements of the IRC? Yes No / :f!. Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable roptns? Yes No / pA Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety glazing for these areas? Yes No _ __,.,A/'-'-Jl'----- Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? , 1 D. Yes No __ _,_["_f_' __ _ Do you understand that if you are building on a parcel of land created by the exemption process or the s/b ivision process, are building plans in compliance with all plat notes and/or covenants? · Yes · No ____________ _ Do you understand that if you belong to a Homeowners Association (HOA), it is your responsibility to obtain written permission from the association, if required by that association, prior to submitting an application for a building permit? The building permit application will be accepted without it, but you run the risk of the HOA bringing action to enforce the covenants, which can result in revocation of permit issued. Additionally, your Plan Review fee is not refundable if the plans have been reviewed by the Building Dep ment prior to any action by the HOA that requires either revocation or substantial mo ification of the plans. Yes No ____________ _ Will this be the only residential structure on the parcel? ~-rp..(iJ/ <-- Yes No If no-Explain: ____________ _ Have two (2) complete sets of consttuction drawings been submitted with the application? 4 Yes. ____ _ 24. Do you understand that the minimum dimension a home can be on a lot is 20ft. wide and 20ft. long? Yes No ______ _ 25. Have you designee! or had this plan designed while considering building and otber construction cQde'fequirements? Yes / No. _______ _ 26. Do your plans comply with all zoning rules and regulations in the County related to your properties zone dis!J:i.Gt'? Yes / No ______ _ 27. Does the plan accurately indicate what you intend to construct and what will receive a final inspection byye Garfield County Building Department? Yes No ______ _ 28. Do you understand that approval for design and/or construction changes are required prior to the application f these changes? Yes No ______ _ 29. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application submittal and that you will be required to pay the "Permit Fee" as well as any "Road/pact" or "Septic System" fees required, at the time you pick up your building permit? . Yes . No _____ _ 30. Are you aware that you must call in for an inspection by 3:30 the business day before the requested inspection in order to receive it the following business day? Inspections will be made from 7:30a.m. to 3:30p.m. Monday through Friday. Inspections are to be called in to/384-5003. Yes J No. _______ _ 31. Are you aware that requesting inspections on work that is not ready or not accessible will result in a $/0.00 re-inspection fee? Yes No ________ _ 32. Are you aware that you are required to call for all inspections required under the IRC including ap 1 roval on a final inspection prior to receiving a Certificate of Occupancy and occupancy o the building? Yes No ______ _ 5 33. Are you aware that the Permit Application must be. signed by the Owner or a written authority being given for an Agent and that the party responsible for the project must comply with the IRC?/. Yes No ____________ _ 34. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups, unless you as the homeowner are performing the work? The license number of the person. performing the work will be required at time of~applicable inspection. Yes ~ No ______________ _ 35. Are you aware, that on the front of the Building Permit Application you will need to fill in the Parcel/Schedule Number for the lot you are applying for this permit on prior to submittal of a building permit application? Your attention in this. is appreciated. Yes / No __________ _c__ 36. Do you know that the local fire district may require you to submit plans for their review of fire safety issues? Yes ~ No (please check with the building department about this requirement) 37. Do you understand that if you are planning on doing any excavating or grading to the property prior to issuance of a building permit that you will be required to obtain a grading permit? Yes _.--/ 38. Are you aware that if you will be connecting to a public water and/or sewer system, that the tap fees have to be paid and the connections inspected by the service provider prior to the issuance of a Certificate of Occupancy? Yes / I hereby acknowledge that I have read, understand and answered these questions to the best of my ability. ~ !oZ-'b-z.:>=>C Signature of Owner Date Phone: __ 3_7-'--/-_Lf_~_b_( ___ (days); __::6::__c}..__5'_··_d-_C.-"'t'--C-___ ·( evenings) Project Name: re. T ~ C/rAr"4"'- Project Address: __ -'7--'<fc...o __ H_A_I :.../ t.v"""'A'-I,Y'--'-Ac.."'c..:. '-=-_,_fL_)...:.f:._. '-'! (_~------------ 6 Notes: If you have answered "No" on any of the questions, you may be required to provide this information at the request of the Building Official prior to beginning the plan review process. Delays in issuing the permit are to be expected. Work may not proceed without the issuance of a permit. If it is determined by the Building Official that additional information is necessary to review the application and plans to determine minimum compliance with the adopted codes, the application may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review, delay in issuance of the permit or delay in proceeding with construction. Bpminreq November2006 7 GARFIELD COUNTY BUILDING REQUIREMENTS Codes: 2003 IRC, IBC, IFGC, IMC, IPC, Setbacks: Check subdivisions and zone district for setback requirements. Snowload (measured at the roof): 40PSF up to 7000ft. elevation. Seismic design category: B SOPSF 7001 to 8000ft. 75PSF 8001 to 9000ft. IOOPSF 9001 to 10000ft. Weathering probability for concrete: Severe Termite infestation probability: None to slight Wind speed: 90mph Decay probability: None to slight Wind Exposure: B or C (see section R301.2.1.4) Frost Depth: 36in. to 8000ft. elevation. 42in. 8001 and above. Winter Design Temperature: Minus 2 to 7000ft.; minus 16 over 7000ft. elevation. Air Freezing Index: 2500deg F-days to 7000ft.; over 7000ft. to be determined by Building Official. Ice shield under-layment required. Mean Annual temp.: Variable Insulation: Maximum glazing U factor: 0.50 Minimum R-Values: • Ceilings/roofs R values are: R-30 stick built structures. R-38log construction and steel rafter construction. • Walls R values are R-19 wood frame; R-19 cavity R-3 sheathing steel studs. • Floors R-values are R-19. • • • Basement wall R-values are R-IO below grade, R-19 above grade. Slab perimeter R -value and depth is R- 10/36in. Crawl space wall R-valnes are R-IO below grade and R-19 above grade If floors over crawl spaces are not insulated, the crawl space walls must be insulated. Basement wall must be insulated to frost depth. Common walls garage to house must have R -19 insulation. Common ceiling/floor garage to house must have R -19. Take precautions to protect plumbing in these areas. PLAN REVIEW CHECKLIST Applicant ~ e Date /~ 35-~ 7 Building _:::__Engineered Fonndation 'Zx. Driveway Permit v-5urveyed Site Plan == Sefltie Pom:mt aaEi Setbacks ~raderropcigrapby 30% _.....----Attach Residential Plan Review List ~nimum Application Questionnaire ~Subdivision Plat Notes ~Fire Department Review /Valuation Determination/Fees Aed Line Plans/Stamps/Sticker __._.d([tach Conditions ~pplication Signed __0ilan Reviewer To Sign Application ~arcel/Schednle No. 4 0# £gowload Tetter-Manf. Hms. _ _.1""...-="'S=--oils Report GENERAL NOTES: __ B ilding Height Z nina Sirrn-off --"' " __ R ad Impact Fees __ Subdivision Plat Notes Tereasa Baker From: Wendy Mead Stmt: Monday, October04, 2004 6:50 AM To: Tereasa Baker · Cc: Kr:aig Kuberty S11bject: Kelth Petree Exemption Letter HiTereasa, Here is an exemption letterf~~ · · . . . His driveway is. entering frQm Fali'Way Ave, which is in thEl Cil)l of Rifle. Gartie!o Counly has no juriSdlca6on. He doesn't have an address yet but Kreig gave me 217709300097 as a property number(?). Mr. Petree's cell phne number.is 379-4966 If you have any fUrther questions, please contact Kraig directly. Have a great day! Wendy STATE ELECTRICAL BOARD INSPECTION REPORT / CORRECTION NOTICE ,..,. (.'' _,, ·•') Date Rec. ;;t' r / -~ (' "; ' ,. .· . ") ./ •. t ~~ :' . -~ Contractor I Home Owner: _ _;,./L.{ '+, .·::z.7 :::,.i/-:<. t::.<"'LLi.,;;.-·. --"'··. c.:· l~.ru'":,.,'':-:;..-1_<. ____ _ ' TYPE OF INSPECTION: J Partial --Rough in __ Underground __ _ • ! .. Final~';_{_ ACTION: Accepted . ~'~l .1 I Rejected __ _ /:>" Remarks __ _ ---REINSPECTION FEE Comments or Corrections:------------- Inspector's Name Phone#~·-·-'-·--"·,_----'--'------ FORMS:EBINSP_NOTICE.DOC -INSPECTION WILL NOT BE MADE UNlESS THIS CARD IS POSTED ON THE JOB 24 HOURS NOTICE REQUIRED FOR INSPECTIONS BUILDING PERMIT GARFIELD COUNTY, COLORADO Date lssued .. '/.9{.Q.1 .... Zoned Area ....•••••••••...•.•••.•••.•..•• Permit No .•. J.Q~CJ.Y. ...... . AGREEMENT In consideration of the issuance of this permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building lnspe~tor an~ IMMEDIA'J:ELY BECOME NULL AND VOID. use ..f"tA.chE-6\ Go.ra. ~ Setbacks Front Side Side Rear This Card Must Be Posted So It is Plainly Visible From Tb.e Street Until Final Inspection. INSPECTION RECORD Footing Driveway Foundation Underground Plumbing Insulation II) IJ. Rough Plumbing Drywall A/tf Chimney & Vent Electric Final (by Stale Inspector) 2J·Cf ·C> 1 Kf. Gas Piping Final lf-10· o8 Nnf- Electric Rongll (By Stale !"spector) AI j; Septic Final Framing ;~/'2~07 ~ Notes: (To include Roof in place and Windows and Doors installed). ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING - WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND. No. /O:J?!C( . '\j'Jt1 .C-, . Assessor's Parcel No. ·:?Z 1 -{j f.J ·-OC·r:;9] Date 1/ ?/?<t1ZJ 7 I ' • ] v-.. -==h ~ Job Addr" -~ ()U 1 C:tc-:~;_:,~·z"j Owner l~tA__SLJL j(_o..Ocl ' . J \¥; Contractor MA.)~>L. 1 ~l.:::._k_. BUILDING PERMIT CARD · 1 n·-· ···· (' .P(.l ~ 4>~ ' ~~~ . $_:; () \) ':::, (_, S. '~' -vJt. r-· .• ~~ ._· ... _ .. ·-·-'1 ,, '~-~J· VJ() Address'] c· i::L-"-"'-"c'-'7 CL'-''-t V'-'e 6ne # I bJS-J.L~~"b Address Phone # _____ _ ~b~ , Fro?Jt Rear RH LH Zoning lJ,IX_o_~Q~~ ~~~\.....-~({-INSPECTIONS Soils Test r Weatherproofing ___________ _ Footing Mechanical _____________ _ Foundation Electrical Rough (State)---::,--,...--..,--~"'""".--- Grout Elect!i§~l.finru (State) 3'-9· 0 7 !5:JS.____ Underground Plumbing Finaly/!LD!t /Checklist yompleted? ~ Rough Plumbing Certificate Occupancy # -'lJ-""--41.-A,.,_.__ _____ _ Framing /-I'J--o2~ Date----:-:;-;--;;----------- Insulation Septic System # /.J !;A • I Roofmg Date -------------Drywall Final, ____________ _ Gas Piping-----------Other __________________________ _ ~~ NOTES (continue on back) Parcel Detail Page 1 of 3 Garfield County Assessor/Treasurer Parcel Detail Information A~~g~~or/In:;<l§l!Ic!:PmpertYSc<!r<:h I As_sessor Subset Q1lcXY I AssessoLS_<\Jg~_Search Clerk&: RecordcLReccptimLSc<lrc::h Parcel Detail I Y<tlue Detail I Sales Detail I Residential/Commercial Improvement Iktail Land Detail I Photographs I TaxArea II Account Number II Parcel Number II Mill Levy I I 021 II R210625 II 217709300097 II 45.694 I Owner Name and Mailing Address jPETREE, KEITH D & SHA WNA C I I780FAIRWAY AVENUE I !RIFLE, CO 81650 I Legal Description !SECT,TWN,RNG:9-6-93 DESC: W 200' OF I !LOT 9 R.I.P. IN Wl/2SW BK:0592 I JPG:0568 BK:0589 PG:0011 BK:0542 I IPG:0183 BK:0525 PG:0739 BK:1613 I IPG:18 RECPT:657716 BK:1286 PG:39 I jRECPT:588157 I Location I Physical Address: 11780 FAIRWAY AVE RIFLE I I Subdivision: I Land Acres: 112.16 I Land Sq Ft: 110 Section II Township II Range I 9 II 6 II 93 I htto:/ /www. garcoact.cornl assessor/parcel.asp ?Parce!N umber=217709300097 115/2007 Parcel Detail Page 2 of3 Property Tax Valuation Information II Actual Value II Assessed Value I I Land: II 7o,oooll 20,3001 I Improvements: II 0 11 ol I Total: II 70,00011 20,3001 Sale Date: 119/5/2001 Sale Price: 1197,200 Basic Building Characteristics Number of Residential lo I Buildings: Number of Commllnd lo I Buildings: No Building Records Found Tax Information I Tax Year II Transaction Type II Amount I I 2006 II Tax Amount II $927.601 I 2005 II Tax Payment: Second Half II ($465.60)1 I 2005 II Tax Payment: First Half II ($465.60)1 I 2005 II Tax Amount II $931.201 2004 II Tax Payment: Second Half II ($425.19)1 2004 II Tax Payment: First Half II ($425.19)1 2004 II Tax Amount II $850.381 2003 II Tax Payment: Second Half II ($471.58)1 2003 II Tax Payment: First Half II ($471.58)1 2003 II Tax Amount II $943.161 2002 II Tax Payment: Second Half II ($446.20)1 I 2002 II Tax Payment: First Half II ($446.20)1 I 2002 II Tax Amount II $892.401 I 2001 II Tax Payment: Second Half II ($455.79)1 I 2001 II Tax Payment: First Half II ($455.79)1 I 2001 II Tax Amount II $911.581 I 2000 II Tax Payment: Whole II ($920.08)1 I 2000 II Tax Amount II $920.081 II II http://www. garcoact. corn! assessor/parcel.asp ?ParcelN umber=217709300097 1/5/2007 Parcel Detail 1999 II Tax Payment: Whole II ($922.48)1 1999 II Tax Amount II $922.481 Top ofPag\< A~~e§~oLR<:tt<:ll::>a>e S9<!feh0Ption$ I Trea~;mer Da_t<tbase Sear.rh Options Clerk & Recorder Database Search Options Page 3 of3 The Garfield County Assessor and Treasurer's Offices make every effort to collect and maintain accurate data. However, Good Turns Software and the Garfield County Assessor and Treasurer's Offices are unable to warrant any of the information herein contained. Copyright © 2005 -2006 Good Turns Software. All Rights Reserved. Database & Web Design by Good Tums Software. http://www .garcoact.com/assessor/parcel.asp?Parce!Number=217709300097 115/2007 APPROVED SUBJECT TO NOTED EXCEPTIONS & INSPECTIONS GARFIELD COlJNT"i' ~~iii!~ NO l!llfiCTION WITHOUT 'l'!OSE PLANs oN sm ~ of (Jl~r:J ~~~(/ .SooTH EL\Slfl'tT10"" ~-·--.__~~ ~~ ~0 YR. ARC. Roofil-l& ~ ,~· . ~", ;;:::-! 5 %-os~ s~e-v ~NG-INfER~D iRiJS~ A ·-~~-·-tv/ ~0 LB LO;rb_ ::.__.../ ~ n' ~~~ t{ut<.RIU:.l'le e.uP 1 ! !tl '5<~r--;_ 'II u~ ' l_·l ! H-I lj /2u 1 il_\ s-ruco I 'Y .r--, 'I~ I (I I ll n ~ -~ ~ --:::~::~:~::/·_.--/~ '·········-.___~ / I " I<· II ~ 1 /JI 1VtrvJ I q /~~.~~~ ~ ~ D D ~D '· 0 ~~tq SCALe-~::\' 0 fcd_-l- 5 I ll l .I :J '1/. fRt;iYl!N G-\LJi'~os; II ~X(. Ti< J..-~c..ol!J NOT lfe.Ju z...~- i /h>pl lJw·J fvl(. . 3 l ':> [ r"""' rl e () 0 WU 3 '3 I [LC-~ n c~ ;.J.I , 1'-~ fff{) TO $CA~ -<s-~ " 9<:/- l ~ "" " <> 0 . ~') to In ______, _L <::) ~ (- I I I I I I l I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I ,_ SITE PLAN The West 200 Feet of Lot 9, in the Wl/ 2sw 1/4 of Section 9, Township 6 South, Range 93 West of the 6th P.M., Said Lot 9 being in the Rifle Irrigation and Power Company Plat as shown by Document No. 35613, County of Garfield, State of Colorado SCALE: 1 "=60' 40.0' Proposed Shed 40.0' BUILDING DETAIL SCALE: 1 "-20' NOTE: TIDS PARCEL IS SUBJECT TO RESERVATIONS, RESTRICTIONS, COVENANTS AND EASEMENTS OF RECORD OR IN PLACE. -~ o/J~ • e"-ce--...,_. N 89°27'37" E 200.00' #5 Rebar in Place$---,---,--".~.:..:;;:,;:.;:;:.:..~...;;:,_..,.::==.;;:_--, Site Benchmark Elev.~5452.94' I I I I I '"' OldFence "-' 46.4' ' I : ~ ~ " 1---164.9'1 ~+,-,"'-r , r" I '.._ ':0'\0 I : \ "'o." \ I : ) <:/~.. "-.... I : ( I : ~ I : o I : ~ 37.3' 0'1 I : fC-.LL'-"~---\--93.1' Top of Bank~\\ Ctl "'-..... 2 g 11---166.9': ~ I : I : I I I I I I I r I / /I \Existing House I { I : Utility Stubo / I .J.-Electric I 1 Er i Transformer ~ I I I i \0 j I I )-Proposed 0," I I I/ : Dedication for 1 25.0' 1 Fairview I I I I I : 11, ~ I I ~ I ""I 243.2' ~ tl I 1q ~I I ~: ·E:J I ~I 1:4 I 'B: t;l "'I C'ij I til: I : 1 45.o' r-- 1 I : I : ( I : I s 89°29'37" w ~Fairview Avenue \ 8 ,\ ----1..:: 82. \ 0'1 \ g I ' trl ! I I I ' TopofBank 'f The West 200 Feet of Lot 9, R.I.P. 200.00' NOTES 1.) THIS SURVEY WAS PREPARED WITHOUT THE BENEFIT OF A CURRENT TITLE COMMITMENT AND DOES NOT REPRESENT A TITLE SEARCH BY TffiS SURVEYOR OR BOOK CLIFF SURVEY SERVICES, INC. OF THE PROPERTY SHOWN .TO DETERMINE OWNERSHIP, COMPATIBiliTY WITH ADJOINING PARCELS, OR EASEMENT OR ENCUMBRANCES OF RECORDS AFFECTING THIS PARCEL. 2.) THE PROPOSED BUILDING SITE IS NOT LOCATED WITffiN A 30% SLOPE AREA. 3.) THIS SITE PLAN DOES NOT REPRESENT A BOUNDARY, IMPROVEMENT OR IMPROVEMENT LOCATION CERTIFICATE SURVEY BY BOOKCLIFF SURVEY SERVICES, INC. OR ANY OF ITS ASSOCIATES. 4.) APPROXIMATE ELEVAIJON OF THE SITE, BASED ON THE #5 REBAR AT NE CORNER OF LOT THE ELEVATION BEING 5452.94' AS USTED HEREON. SURVEYOR'S STATEMENT PROJECT NO, 04103~ SHEET 1 Of I