Loading...
HomeMy WebLinkAboutApplication-Permit. Garfield County Building & Sanitation Department 108 Kh Street, Suite #401 Glenwood Springs, Co. 81601 Office-945-8212 Inspection Line-384-5003 Job Address (o4t{.-5 c_Q__ ll'] {;c_;)S I NO . 10298 Nature ofWork Building Permit ())395-/5'Cj-C::{) _.,DO] UseofBuilding 5/J' 00 unf'bJ.:SrJ_.u.Jf cdl!~~fVl-t,,-,.s ...--r ~~ Owner I ru.bv'e.1 1\d '+--1\...oq__ Contractor a~ (\e_r- Amount of Permit $ E)[ d3. /7 GARFI E LD COUNTY BUILD I NG PERM IT A PPLI CATI ON 108 8 ." Street, Sui te 401 . Glenwood Springs, CO 8 1601 Phone: 970·945·8212 I F ax: 970·384-3470 I Inspection Line: 970·384-5003 Permit No: ( ~C{2( J o b Address: Parcel/Sch edule No: fJ.. Y/5-/5 LJ. -ro ~co l 6-~5. ~ y/bO I 2 3 4 5 tl Use of Buil d ing: 7 Desclibe Work: ~ Class of Work: 0 ~) 0 S ing le Double 10 11 NOTIC A SEPARATE ELECTRICAL PERMIT IS REQUIRED AND MUST BE ISSUED BY THE STATE OF COLO RAD O. PH Subd. I Exemption: Alte r a tion Addi ti on 0 Move On-S ite Sewage Dis posal Carport: ~l tePlan Adj u sted Valuation s: S C. D . Permit Fee: \1/k Ph: 97o -~~.scy Lie. No. Li e. No. 0 Single 0 Doubl e "3/<Dt. 9~ TillS PERMIT BECOMES NULL AND VOID I F' WORK OR CONSTRUCTION AUTH ORIZED IS NOT COMMENCED WlTH LN ISO DAYS. OR. IF CONSTRUCf!ON OR WORK I S SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY T I ME AFTER WORK IS COMMENCED. T otal F ee: \ Dat e d Pe rmit Iss u ed: 1 HEREBY CERTI FY THAT 1 HAVE READ AND EXAMI NED TH I S APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PRO VISI ONS OF LAWS GOVERNING T HIS TYPE OF WORI< Wl LL BE COM PLETED WITHIN WHETHER SPECIFIED H EREI N OR NOT. T H E GRANTING OF A Pi::RMIT DOES NOT PRESUME TO GIVE AUTHORI TY TO VIOLATE OR CANCEL THE PROVISI ONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OFCON CTI ON . ?. /2-~ ./7 -t/50- Zoning: Ma nu . Ho m e: AGREEMENT PERMISSION I S HEREBY GRANTED TO THE APPLICANT AS OWN ER CONTRACTOR AND/OR T HE AGENT OF THE CONTRACTOR OR OWNER TO CONSTRUCT THE STRU CTURE AS DETAI LED ON PLANS AND SPECIFI CATI ONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT. IN CONSIDERATION OF T H E I SSSUANCE OF T HIS PERM IT , THE SIGNER HEREBY AGREES TO COMPLY WlTH ALL BUILDING CODES AND LAND USE REGULATIONS ADOPTED BY GARFI ELD COUNTY PURSUANT TO AUTHORITY GIVEN LN 30.28.201 CRS AS AMENDED. THE SIGNER FURTHER AGREES TIIAT I F T H E ABOVE SAID ORDINANCES ARE NOT FULLY COMPILED \VITH IN THE LCOATION. ERECTION, CONSTRUCTION , AND USE OF THE ABOVE DESCRIBED STRUCT URE. T H E PERM IT MAY BE REVOKED BY NOTICE FROM THE COUN TY AND THAT THEN AND THERE IT SHALL BECOME NULL AN D VOID. THE ISSUANCE OF A PERMT BASED UPON PLANS, SPECWICATI ONS AND OTHER DATA SHALL NOT PREVENT THE BU I LDI NG OFFI CIAL FROM TH EREAFTER REQU I RING T H E CORRECTI ON OF ERRORS I N SAID PLANS. SPECIFICAT I ONS AND OTHER DATA OR FROM PREVENTI NG BUILDING OPERATI ON BEI NG CARRIED ON THEREUNDER WHEN I N VIOLATION OF THS CODE OR ANY OTHER ORDI NANCE OR REGULATI ON OF THIS JURISDICTI ON. THE REVIEW Of SUBMITTED PLANS AND SPEC I FI CATIONS AND INSPECf!ONS CONDUCTED T HEREAFTER DOES NOT CONSTITUTE AN ACCEPTANCE OF ANY RESPONSIBI LITIES OR L tABL!TI ES BY GARFI ELD COUNTY FOR ERRORS, OMISSIONS OR D!SCREPENCIES. THE RESPONS! BIL!TY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRU CTION RESTS SPEC!FI CIALLY WlTH THE ARTICTECT. DESI GNER. BUILDER. AND OWNER. COMMENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF T HE OWNERS LNTEREST. "~ 'HEREBY ACKNOWCEDGE THAT' HAVE READ AN D UNDERSTAND THE AGREEPd$3~'1 'WWu.t tee_ \)\~~\0~ .0 v..~l,\"'J CJl# {[)63 l-t :d --67 ~~ \ ~:~'c)''~ The following items are required by Garfield County for a final inspection: 1. A final Electrical Inspection from the Colorado State Electrical Inspector; 2. Permanent address assigned by Garfield County Building Department posted where readily visible from access road; 3. A finished ro of, a lockable hou se , complete exterior s iding, exterior doors and windows install ed, a complete kitchen with cabinets, a s ink with ho t & cold running water, non-absorbent kitche n floor coverings, counter top s and finished walls, ready for stove and refrigerator, all neces sary plumbing; 4. All bathrooms must be complete , with washbowl, tub o r shower, toilet s tool, hot and cold running water, non-absorbent floors and walJs finished and a privacy door; 5. All steps outside or ins ide over three (3) steps mu st have handrail s, guard rails on balconies or decks over 30" high constructed to alJ IBC and IRC requirements; 6. Outs ide grading done to where water will detour away from th e building; 7. Exceptions to the outside step s , decks and grading may be made upon the demon s tration of extenuating circumstances, i.e. weather, but a Certificate of Occupancy will not be issued until all th e required items are completed and a final inspection mad e; 8. A final inspec tion sign off by th e Garfield County R oad & Bridge Department for driveway installation, where applicable; as well as any final sign off by the Fire Dis trict , and/or State Agencies where applicable. A CERTIFICATE OFOCCUPANCY WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. ****CANNOT OCCUPY OR USE DWELLING UNTIL A CERTIFICATE OFOCCUPANCY (C.O.) IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. I und ers tand and agree to a bide by th e a bove conditions for occupancy, use an d the issuance of a Certificate of Occupancy for th e dwelling under building permit# /O'&Xj 1?' Signature Bpapplicationfeb2006 Date GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS For SINGLE FAMILY DWELLING CONSTRUCTION Including NEW CONSTRUCTION ADDITIONS ALTERATIONS And MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. When reviewing a plan and it's discovered that required information has not been provided by the applicant, this will result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor shall be required to provide this information before the plan review can proceed. Other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. Any project with more than ten (10) occupants requires the plans to be sealed by a Colorado Registered Design Professional. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following checklist prior to and during design. Applicants are required to indicate appropriately and to submit the completed checklist at time of application for a permit. Plans to be included for a Building Permit, must be on drafting paper at least 18"x24" and drawn to scale. 1 Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks, balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line and original grade. A section showing in detail , from the bottom of the footing to the top of the roof, including re-bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house-rap, (which is required), siding or any approved building material. Engineered foundations may be required. A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M .P .H. wind speed, wind exposure B or C , and a 36 inch frost depth. All sheets to be identified by number and indexed. All of the above requirements must be met or your pla ns will be returned. All plans s ubmitted must be incompliance with the 2003 IRC. 1. Is a site plan included that identifies the locatio n of the proposed structure or addition and distances to the property lines from each comer of the proposed structure(s) prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Prope1ties w ith s lopes of 30% or greater must be shown on the si te plan. (NOTE Section: 106 .2) Any site plan for the placement of any portion of a structure within 50 ft . of a prope1ty line and not within a previous ly surveyed building envelope on a subdivision final plat shall be prepared by a licensed surveyor and have the surveyor's signature and professional stamp on the drawing . Any structure to be built within a building envelope of a lot shown on a recorded subdivision plat shall include a copy of the building envelope as it is shown on the final plat with the proposed structure located within the ~velope. Yes -~ ---- 2. Does the site plan also include any other buildings on the property, setback easements and utility easements? Please refer to Section 5.05.03 in the Garfield County Zoning Resolution if the property you are applying for a building permit on is located on a comer lot. Special setbacks doy.pply. Yes V 3. Does the site plan include when applicable the location of the I.S .D.S. (Individual Sewage Disposal System) and the distances to the property lines, wells (on subject property and adjacent pty¢'rties), streams or water courses? Yes V ---- 2 4. Does the site plan indicate the location and direction of the County or private road accessing the propert~ Yes //' -~--- 5. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the IRC or per stamped engineered design? Yes ~ · 6 . Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and earth? Yes l~ 7. Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces and so!Jits? Yes IL_ 8. Do the plans include design loads as required by Garfield County for roof snow loads, (a minimum of 40 pounds per square foot up to & including 7,000 feet above sea level), floor loads and wind loads? Yes ~ 9. Does the plan include a building section drawing indicating foundation, wall, floor, and roof construction? Yes V" 10. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafte_rs or joists or trusses? Yes ~ 11. Does the building section drawing or other detail include the method of positive connection of all columns and beams? Yes ~ 12 . Does the elevation plan indicate the height of the building or proposed addition from the undisturbed grade to the midpoint between the ridge and eave of a gable or shed roof or the top of a flat roof? (Building height measurement usually not to exceed 25 feet) Yes ~ 13 . Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase II certifications or phase II EPA certification? Yes No ~ 3 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. Do es the plan includ e a masonry fireplace including a firepl ace sec tion indicating design to comply with the IRC? Yes No ------- Does the plan include a window schedule or other verification that egress /rescue windows from sleeging room s and/or basements comply with the requirements of the IRC ? Yes V No ------- Doe s the plan include a window schedule or other verification that windows pro vide natural light and ventilation for all habitable rooms? Yes v No ------- Do th e plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors ; fixed glass panels ; shower doors and tub enclosures and specify safety glazing for these areas? Yes V No ------- Is the location of all natural and liquid petroleum gas furnaces , boil ers and water heaters indicated 01ythe plan? Yes V No ------- Do you understand that if you are building on a parcel of land created by the exemption process or the subdivision process, are building plans in compliance with all plat notes and/or covenants? ~ Yes v/ ~ No __________ _ Do you understand that if you belong to a homeowners association, it is your responsibility to obtain written permission from the association, if required by that as sociation, prior to submitting an application for a building permit? The building permit application will not be accepted without it. Yes v,d J No _____ _ Will this be the only residentia~cture on the parcel? . Yes No tL__ Ifno-Explam: ~·S';.,h 9 f?I".€-.A-6 /IN~ 1'o & ~n Jc qs ,ft..p/, 'o Have two (2)...complete sets of construction drawings been submitted with the application? Yes ~ ____:::;..._ ___ _ Do you understand that the minimum dimen sion a home can be on a lot i s 20ft. wide and 20ft. long? Yes V No ------ 4 24. Have you designed or had this plan designed while considering building and other construction code requirements? Yes V No ____ _ 25. Do your plans comply with a ll zoning rules and regulations in the County related to you r properties z ~e distric t? Yes V No ------- 26. Does the plan accurately indic ate what you int end to construct and what will rece ive a final in spect ion by the Garfield County Building Department? Yes ~ No _________ _ 27. D o you understand tha t approval for design and/or construction changes are required prior to the ap plication of the se changes? Yes IL No ------ 28. Do you understand that the Building D epartment will collect a "Plan Review" fee from you at the time of application submittal and that you will be r equired to pay the "Permit Fee" as well as any "Road Im pact" or "Septic Sys t em" fees required , at the time yo u pick up your building permit? Yes ~ No ____ _ 29. Are you aware that you must call in for an inspection by 3:30 the business day before the requested inspection in order to receive it the following business day? Inspections will be made from 7:30a.m. to 3:30p.m. Monday through Friday. Inspections are to be called in to 384-5003. Yes ~ No ------- 30. Are you aware that reques ting inspections on work that is not ready or not accessible will result in a $50 .00 re-inspection fee ? Yes ~ No ------- 31. Are you aware that you are required to call for all inspections required under the IRC including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of the building? Yes t/ No _____ _ 32. Are you aware that the Permit Application mus t be signed by th e Owner or a written authority being given for an Agent and that the party responsible for the project mus t comply with the IRSJ- Yes V No ------- 5 33. Are you aware that prior to submittal of a building permit application you are required to show proof of a driveway access permit or obtain a statement from the Garfield County Road & Bridge Department s tatin g one is not necessary? You can contact the Road & Bridge Department at 625-8601. Yes e.kiJ1f'th't117 No Al/4 10-e.e afo {led 34. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installation s and hookups, unless you as the homeowner are performing the work? The license number of the person performing the work will be required at time of applicable inspection . Yes ~/ No ______ _ 35. Are you aware, that on the front of the Building Permit Application you will need to fill in the Parcel Number for the lot you are applying for this permit on prior to s ubmittal of a building permit application? Your attention in this i s appreciated. Yes b~ No ______________ __ 36. Do you know that the local fire di strict may require you to submit plans for their review of fire safety issues? Yes L/ No (please check with the building department about thi s requirement) 37. Do you understand that if you are pl anning on doing any excavating or grading to the property prior to issuance of a building permit that you will be required to obtain a grading permit? Yes ~ I hereby acknowledge that I have read, understand and answered these questions to the best of my ability. ~(~~ Signature of Owner Date Phone: 970 -9Jq ~ SOl .l. (days); __ J_9.!_?o==---~ ---'~'--, yL..r'--~-f'::......!--9.:...../ <-_Jt~_( evenings) Project Name: f;., love... /lesr'cifnc.JL Notes: If you have answered "No" on any of the questions, you may be require d to provide this information at the request of the Building Official prior to beginning the plan review process. Delays in i ssuing the permit are to be expected. Work may not proceed without th e issuance of a permit. If it i s determined by the Building Official that additional information i s necessary to review the a ppli cation and plans to determine minimum compliance with the adopted codes , the application 6 may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review, delay in issuance of the permit or delay in proceeding with construction. BpminreqFeb2005 7 GARFIELD COUNTY BUILDING REQUIREMENTS Codes: 2003 IRC, IBC, IFGC, IMC, IPC, Setbacks: Check subdivisions and zone district for setback requirements. Snow load: 40PSF up to 7000ft. elevation. SOP SF 7001 to 8000ft. 75PSF 8001 to 9000ft. 1 OOPSF 9001 to I OOOOft. Seismic design category: B Weathering probability for concrete: Severe Termite infestation probability: None to slight Wind speed: 90mph Decay probability: None to slight Wind Exposure: B or C (see section R301.2.1.4) \ Frost Depth: 36in. to 8000ft. elevation. 42in. 8001 and above. Winter Design Temperature: Minus 2 to 7000ft.; minus 16 over 7000ft. elevation. · Air Freezing Index: 2500deg F-days to 7000ft.; over 7000ft. to be determined by Building Official. Ice shield under-layment required. Mean Annual temp.: Variable Insulation: Maximum glazing U factor: 0.50 Minimum R-Values: • Ceilings/roofs R values are: R-30 stick built structures. R-38 log construction and steel rafter construction. • Walls R values are R-19 wood frame; R-19 cavity R-3 sheathing steel studs. • Floors R-values are R-19. • • • Basement wall R-values are R-IO below grade, R -19 above grade. Slab perimeter R-value and depth is R- 1 0/36in. Crawl space wall R-values are R-10 below grade and R-19 above grade If floors over craw) spaces are not insulated, the crawl space walls must be insulated. Basement wall must be insulated to frost depth. Common walls garage to house must have R-19 insulation. Common ceiling/floor garage to house must have R-19. Take precautions to protect plumbing in these areas. PLAN REVIEW CHECKLIST Applicant ~Y LuvfL Date /::J ' 17 '<0 Building 1A A. Engineered Foundation ':f\.IYi~·-u . .f-1 t #P--~ ftU~ 0 )( Driveway Permit 0)\u.. c~ lff'11 .• ~ ~· r-;i~«.b ~ --~ed Site Plan /5:J f vJ~~ ~ ~ptic Permit a nd Setbacks . ~effopography 30% ~tach Residential Plan Review List ~imum Application Questionnaire ~Subdivision Plat Notes tl~epartrnent Review Valuation Determin at ion/Fees ~ine Plans/Stamps/Sticker --4•h Conditions --2_plication Signed __ Plan R ev iewer To Sign Application ---.J.rcel/Schedule N o. --JLl40# Snow load Letter-Manf. Hms. J1.L_ Soils Repmt GENERAL NOTES: Planning/Zoning ~operty Line Setbacks --#A.30ft Stream Setbacks ~Flood Plain ~Building Height /zoni ng Sign-off ~Ro ad Impact Fees 1{/l.. HON~RC Approval _LGradeffopography 40% UJL_Planning Is sue s ~bdivision Plat Notes April261h, 2007 Mr. Ty Trulove 6445 Co unty Road 117 William J. Young 3960 South Pinehurst Circle Denver, Colorado 80235 303-881-6631 Glenwood Springs, CO 81601-4523 (970) 945-5914 RE: Footer Construction New Residence Dear Mr Trulove : I have reviewed the footer area of concern, a large rock, in line with the house footer. I have determined that the footer may gap up to four feet to pass the large rock , footer steel may also stop on each side of the gap. The concrete structural system for the house is adequate to allow the gap in the footer. The house wall may be pl aced directly upon the existing rock. If you have additional questions or need additional information, please call me at (303) 881-6631 . / -·· <. November 51 \ 2007 Mr . Ty Trulove 6445 County Road 117 William J. Young 3960 South Pinehurst Circle Denver, Colorado 80235 303-881-6631 Glenwood Springs, CO 81601-4523 (970) 945-5914 RE : Framing Inspection Dear Mr Trulove: I have inspected the new construction at the above address for properly constructed structural framing. I have reviewed the structural plans and actual construction, it is my opinion that the structural system for this residence has been constructed properly to carry the minimum code prescribed design loads for this residence. If you have additional questions or need additional information, please caB me at (303) 881-6631. March 14, 2008 Garfield County Building and Planning RE: Ty and Tina Trulove Residence To Whom It May Concern: Ty and Tina Trulove have converted prior residence at 6445 County Rd. 117 Glenwood Springs, CO. into a workshop above a garage. Ty and Tina have no intentions of renting the workshop . COUNTY OF GARFIELD -BUILDING DEPARTMENT CORRECTION NOTICE 108 8th St., Suite 401 Glenwood Springs, Colorado Phone (970) 945-8212 Job located at 6Lf /.f!) 61<//7 Permit No. /0;;.9f? I have this day inspected this structure and these premises and found the following corrections needed: ~Call for Re-lnspection ... 0 $50.00 Re-lnspection Fee must be paid prior to Re-Jnspection You are hereby notified that the above correction must be inspected before covering. When correction(s) have been made, call for inspection at 970-384-5003. Date 3-/3-og 20=------ Building Inspector ~~~ Phone (970) 945-8212 M COUNTY OF GARFIELD -BUILDING PERMIT CORRECTION NOTICE 108 8th St., Suite 401 Glenwood Springs, Colorado Phone (970) 945·8212 Job located at 6 9/i.r C/{/17 PermitNo.~~~0~~9~8~/--~----------------------- I have this day inspected this structure and these premises and found the following corrections needed: 1) ~/(!, /~k f-mn ~· c?-L c;a-A$_,_ ~ ~ ~ .l) ~ tfo~ ,~~4--/ ·i/~ #c~--t~. You are hereby notified that the above correction must be inspected before covering. When corrections have been made, call for inspection at 970·384-5003. Date '/-!l~o7 20 .. Building Inspector -;/.~~ Phone (970) 945-8212 No.JDCflezi Assessor's Parcel Nod39,,'5-/5"t..f-ffi-OO? Date 1-fa-{)7. BUILDING PERMIT CARD ,,_,h JobAddresstoY4~ CJL l \7 GL..0S ( q4s'-591~ Owner I ru~g :JU+=ri f)CL Address 6a J'N) Phone #99Ft-50[~ Contractor ~ 22~r Address _________ Phone#~ Sp~cks: Front Rear RH· _____ LH _____ Zoning ----- S/1;-·~rl UJI-1-:tx:tSe__. Wf a.:J=:t. INSPECTIONS Soils Te&jaf\o.e,e ~~ Weatherproofing . . Footing 4-19.-o7~ Mechanical liM c:\v......v. lo-3 1 -c') 4--> k Foundation 't-~Z-o?~ Electrical Rough (State) _,rJ"---"'"""--r''------- Grout Electrical Final (State)-------7""--- Underground PlumbingS-/G7 P'fu ~inal 3-Jt.f-o!S /Checklist Completed?~v __ Roug_h Plumbing It? -31-o1 9ft . Certificate Occupancy # ---=S~Z.,.:O._H~---:=----- Frammg Lo :.3\-~\ 1.. ~-£""'-·-'...,~ _ Date \~uecl '3-.d,0-03" Insulation ll~i0--o3ib a:tl'.fh<j0/.£:n."1. ,,-t? Septic System#....,......_ 4''-..,S4!C .... 6""-)3.._._-=------ Roofing -t . . . Date (-12-07 ..¥Drywall lo--sr -011. Jli,l/L/-J<?<?7~Jk~ Final a:-Ia:-0'3' Gas Piping 0 "7 Other--------------- ~.· · .. ~~'~--'-"·"··· Cd_l,L~Q.. .. ~:"·~-' NOTES .~ L)f)#. aU'~ f;:{-~-£17~ ;,; ·.·'.·."~'' •.. ,.:;:;;i:~.;~.J.,."'~f.i.·.· ........ --.~ ~"" "'!'J\.; r:--ri~.·t2:f·"1"t'r."~.l ... i,,b..,l.·~· .. ·. ~ . .rP: "·" ·~~~~~~~~ ' ' 'Ut~C):JU R::,. ~-~ -~, ..• ,,~\7~\"'"~-.-;..u~r.r~~~l'£>.~~,1!'~-;;'~"~·.-~t~.i;,;c~~,~"· -~~~~,F~~-.:.~ .. -~~~lt':~l;?,.\::;i""i-~i.~~i·~··· (continue on back) INSPECTION WILL NOT BE MADE UNLESS THIS CARD IS POSTED ON THE JOB 24 HOURS NOTICE REQUIRED FOR INSPECTIONS BUILDING PERMIT GARFIELD COUNTY, COLORADO Date Issued.f~.1.a~ .. 01. .... Zoned Area ............................... Permit NoJQ:i\9.1 ........ .. AGREEMENT In consideration of the issuance of this permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building Inspector and IMMEDIATELY BECOME NULL AND VOID. Setbacks Front Sjde Side Rear This Card Must Be Posted So It is Plainly Visible From The Street Until Final Inspection. INSPECTION RECORD Footing "?'-17-c?7~ Driveway Chimney& Vent /O-)I~'\ t;J,~;,. ElectricFinal(byStatel~lff ~~ GasPiping · \u-'1'·"" ~~~ Finai3'-/'I-o8'~~A: tYr:! ~E~Ie;;;c;tr;:ic;;.R:o;::u~g~h.l:(B~y~S;::t•::;t•:,:l:=;'\!i~I;~:;::.~~P/=:;;., ... ~S;;e:;;pli:;;'c;,;F;,;i;;;na;,;lliii_g.~.,i.~~:;ff~lfii/~~/:i=.~--1 Framing (), ~L [..,.. 1..-'*' Notes: (To include Ro3nDP!ite atid Wind~ and Doors installed). ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING - WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND. THIS PERMIT IS NOT TRANSFERABLE For Inspections Call 384-5003 I 08 8th Street Glenwood Springs, Colorado APPROVED DO NOT DESTROY THIS CARD oate l"la .. ci7 ey ['J/18 IF PLACED OUTSIDE -COVER WITH CLEAR PLASTIC Parcel Detail Page 1 of 3 Garfield County Assessor/Treasurer Parcel Detail Information Assessmfl):eastJrerPropert.Y Se<ln::h I Asse~J;m:_S_]J];J_set .Q!!m I Assessor Sales Search Clt'!rk&Rec.:on:lerRe<::eptionSt'!arc.:h I?.asic: .... l?.l!ildingCbamcteristics I I<Jx .. Infonnation Parcel Detail I Value Detail I Sales Detail I Residential/Commercial Improvement Detail Land Detail I Photographs I TaxArea II Account Number /I Parcel Number II Mill Levy I I oo8 II R080370 II 239515400007 II 63.502 I Owner Name and Mailing Address !TRULOVE, TY & TINA I 16445 COUNTY 117 I !GLENWOOD SPRINGS, CO 81601 I Legal Description lsECT,TWN,RNG:15-7-89 DESC: A TR IN lsE BK:0570 PG:0136 BK:1318 PG:640 IRECPT:595257 BK:1318 PG:638 IRECPT:595256 BK:0639 PG:0568 Location Physical Address: 6445 117 COUNTY RD GLENWOOD SPRINGS! Subdivision: Land Acres: 2.34 Land Sq Ft: 0 Section II Township II Range I 15 II 7 II 89 I Property Tax Valuation Information http://www. garcoact.corn! assessor/parcel. asp ?ParcelN umber=23 9 515400007 10/24/2006 Parcel Detail Page 2 of3 II Actual Value II Assessed Value I I Land: II 150,oooll 11,9401 I Im[!rovements: II 128,70oll 10,2401 I Total: II 278,7ooll 22,1801 Sale Date: II 1/7/2002 Sale Price: II 150,000 Basic Building Characteristics Number of Residential lo I Buildings: Number of Comm!Ind lo I Buildings: No Building Records Found Tax Information Tax Year II Transaction Type I Amount I 2005 II Tax Payment: Second Half ($704.24)1 2005 Tax Payment: First Half ($704.24)1 2005 Tax Amount $1,408.481 2004 Tax Payment: Second Half ($745.68)1 2004 Tax Payment: First Half I ($745.68)1 2004 II Tax Amount $1,491.361 2003 Tax Payment: Second Half ($657.77)1 2003 Tax Payment: First Half ($657.77)1 2003 Tax Amount $1,315.541 2002 Tax Payment: Second Half ($1 ,337 .06)1 2002 Tax Payment: First Half ($1,337.06)1 2002 Tax Amount $2,674.121 2001 Tax Payment: Whole ($2,691.56)1 2001 Tax Amount $2,691.561 2000 Tax Payment: Second Half ($836.77)1 2000 Tax Payment: First Half I ($836.77)1 2000 Tax Amount $1,673.541 I 1999 Tax Payment: Second Half ($771.76)1 I 1999 Tax Payment: First Half ($771.76)1 I 1999 Tax Amount $1,543.521 http://www. garcoact.com/assessor/parcel.asp ?ParcelN umber=239515400007 10124/2006