HomeMy WebLinkAboutApplication-PermitPermit No:
Job Address:
GARFIELD COUNTY BUILDING PERMIT APPLI CATION
108 8." Street, Suite 201, Glenwood Springs, CO 81801
Phone: 970-945-8212 / Fax: 970-384-3470 / Inspection Line: 970.384-5003 i� (b lo
`
Parcel/Schedule No: + V 1 O�
Te C G . .'1 60
1 Lot Na: 131act No: Subd. / Exemption:
/( 7 W447 :32 -254U., -254U.' /4 '
2
Owner:
Address r,
Ph•
3
Contractor:
__ / r
Address:
Ph:
Lie. No.
4
Architect/Engiin�eer:
_5441171/4- 1/4–
Address:
Ph:
Lic. No.
5
Sq. Ft. of Suildi�
Ft. of Lot: /7 f /7
Height:
Na. of Floors:
/040.
E.
Use of Building: —
7
Describe Work:
//1Qe,4/ %ei __5-,/,4,43 / el,fr4-2'JAG/// ,1-./
8
Class of Work: New Cl Alteration o Remove
❑ Addition 0 Move
9
10
Gara e: 0 Sin le
DL % V ey ouble`
Carport: 0 Single
0 Double
o Driveway Permit 0 On -Site Sewage
Disposal
Site Plan
11
Valuation of Work: $
Adjusted Valuations: S 71
6(
12
Special Conditions:
NOTICE
A SEPARATE ELECTRICAL PERMIT IS REQUIRED AND MUST BE
ISSUED BY THE STATE OF COLORADO.
THIS PERMIT BECOMES NULL AND VOID 1F WORK OR CONSTRUCTION
AUTHORIZED IS NOT COMMENCED WITHLN 180 DAYS, OR, IF
CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A
PERIOD OF 180 DAYS AT ANY TIME AFTER WORK I5 COMMENCED.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS
APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL
PROVISIONS OF LAWS GOVERNING THIS TYPE OF WORK WILL BE
COMPLETED WITHIN WHETHER SPECIFIED HEREIN OR NOT. THE
GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY
TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR
LOCAL LAW REGULATING C• STRU =1+ , OR THE PERFORMANCE
OF ► o 1 "'U ON�
� .
iiballi
Plan Check Fee:
r� �1 ` h�
(
Permit Fee:
37 7-5
Total Fee:
_7�{' `!) I
l �j
4
Dated Permit Issued:
OCC Gr
!1
it
, 2b:
Const. Type;
Zoning;
Setbacks:
Manu, Home:
7 -a 1,
ISDS No. & Fee:
51 i t •+mrr R Y DA
'/,+
3
BLDG Di;' . PLNG. DEFT.
APPROW/ ' ATE APPROVAL/DATE ' /
AGREEMENT
PERMISSION IS HEREBY GRANTED TO THE APPLICANT AS OWNER, CONTRACTOR AND/OR THE AGENT OF THE CONTRACTOR OR OWNER ID CONSTRUCT
THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT.
IN CONSIDERATION OF THE ISSSUANCE OF THIS PERMIT, THE SIGNER. HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND
USE REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT ID AUTHORITY GIVEN LN 30.28.201 CRS AS AMENDED. THE SIGNER FURTHER AGREES
THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPILED WITH IN THE LCOATION, ERECTION, CONSTRUCTION, AND USE OF THE
ABOVE DESCRIBED STRUCTURE, THE PERMIT MAY 13E REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT SHALL BECOME
NULL AND VOID, THE ISSUANCE OF A PERMT BASED UPON PLANS, SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE BUILDING OFFICIAL
FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING
BUILDING OPERATION BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF THS CODE OR ANY OTHER ORDINANCE OR REGULATION OF
THIS JURISDICTION. THE REVIEW OF SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE
AN ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABLITIES BY GARFIELD COUNTY FOR ERRORS, OMISSIONS OR DISCREPENCIES. THE RESPONSI
BILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICIALLY WITH THE ARTICTECT, DESIGNER., BUILDER,
AND OWNER. COMMENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS LNTEREST.
Garfom.003
I HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE (INITIAL):
Ltinlio
The following items are required by Garfield County for a final inspection:
1, A final Electrical Inspection from the Colorado State Electrical Inspector;
2. Permanent address assigned by Garfield County Building Department posted where readily
visible from access road;
3. A finished roof, a lockable house, complete exterior siding, exterior doors and windows
installed, a complete kitchen with cabinets, a sink with hot & cold running water, non-absorbent
kitchen floor coverings, counter tops and finished walls, ready for stove and refrigerator, all
necessary plumbing;
4. All bathrooms must be complete, with washbowl, tub or shower, toilet stool, hot and cold
running water, non-absorbent floors and walls finished and a privacy door;
5. All steps outside or inside over three (3) steps must have handrails, guard rails on balconies or
decks over 30" high constructed to all IBC and IRC requirements;
6. Outside grading done to where water will detour away from the building;
7. Exceptions to the outside steps, decks and grading may be made upon the demonstration of
extenuating circumstances, i.e. weather, but a Certificate of Occupancy will not be issued until
all the required items are completed and a final inspection made;
8. A final inspection sign off by the Garfield County Road & Bridge Department for driveway
installation, where applicable; as well as any final sign off by the Fire District, and/or State
Agencies where applicable.
A CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL ALL THE
ABOVE ITEMS HAVE BEEN COMPLETED.
****CANNOT OCCUPY OR USE DWELLING UNTIL A CERTIFICATE OF OCCUPANCY
(C.O.) IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE
CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING
PREMISES UNTIL ABOVE CONDITIONS ARE MET.
I understand and agree to abide by the above conditions for occupancy jsse and the issuance of a
Certificate of Occupancy for the dwelling under building permit #
ignature
Bpapplicationfeb2006
Date
GARFIELD COUNTY BUILDING AND PLANNING
970-945-8212
MINIMUM APPLICATION REQUIREMENTS
For
SINGLE FAMILY DWELLING CONSTRUCTION
Including
NEW CONSTRUCTION
ADDITIONS
ALTERATIONS
And
MOVED BUILDINGS
In order to understand the scope of the work intended under a permit application and expedite the
issuance of a permit it is important that complete information be provided. When reviewing a plan
and it's discovered that required information has not been provided by the applicant, this will result
in the delay of the permit issuance and in proceeding with building construction. The owner or
contractor shall be required to provide this information before the plan review can proceed. Other
plans that are in line for review may be given attention before the new information may be reviewed
after it has been provided to the Building Department.
Please review this document to determine if you have enough information to design your
project and provide adequate information to facilitate a plan review. Also, please consider
using a design professional for assistance in your design and a construction professional for
construction of your project. Any project with more than ten (10) occupants requires the plans
to be sealed by a Colorado Registered Design Professional.
To provide for a more understandable plan in order to determine compliance with the building,
plumbing and mechanical codes, applicants are requested to review the following checklist prior to
and during design. Applicants are required to indicate appropriately and to submit the
completed checklist at time of application for a permit.
Plans to be included for a Building Permit, must be on drafting paper at least 18"x24" and
drawn to scale.
1
Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with
decks, balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line
and original grade. A section showing in detail, from the bottom of the footing to the top of the roof,
including re -bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation,
sheeting, house -rap, (which is required), siding or any approved building material. Engineered
foundations may be required.
A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be
designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. wind
speed, wind exposure B or C, and a 36 inch frost depth.
All sheets to be identified by number and indexed. All of the above requirements must be met or
your plans will be returned.
All plans submitted must be incompliance with the 2003 IRC.
1 Is a site plan included that identifies the location of the proposed structure or addition and
distances to the property lines from each corner of the proposed structure(s) prepared by a
licensed surveyor and has the surveyors signature and professional stamp on the drawing?
Properties with slopes of 30% or greater must be shown on the site plan. (NOTE
Section: 106.2) Any site plan for the placement of any portion of a structure within 50 ft.
of a property line and not within a previously surveyed building envelope on a
subdivision final plat shall be prepared by a licensed surveyor and have the surveyor's
signature and professional stamp on the drawing. Any structure to be built within a
building envelope of a lot shown on a recorded subdivision plat shall include a copy of
the building envelope as it is shown on the final plat with the proposed structure located
within t rvelope.
Yes 1-
2. Does the site plan also include any other buildings on the property, setback easements and
utility easements? Please refer to Section 5.05.03 in the Garfield County Zoning Resolution
if the property you are applying for a building permit on is located on a corner lot. Special
setbacks do a ly.
Yes
3. Does the site plan include when applicable the location of the I.S.D.S. (Individual Sewage
Disposal System) and the distances to the property lines, wells (on subject property and
adjacent pro a es), streams or water courses?
Yes l\Ir
2
4. Does the site plan indicate the location and direction of the County or private road accessing
the property?
Yes
5. Do the plans include a foundation plan indicating the size, Iocation and spacing of all
reinforcing eel in accordance with the IRC or per stamped engineered design?
Yes
6. Do the plans indicate the location and size of ventilation openings for under floor crawl
spaces and t e clearances required between wood and earth?
Yes ll/
7. Do the plans indicate the size and location of ventilation openings for the attic, roof joist
spaces and so ts?
Yes
8. Do the plans include design loads as required by Garfield County for roof snow loads, (a
minimum of 40 pounds per square foot up to & including 7,000 feet above sea level), floor
loads and wind loads?
Yes
9. Does the plan include a building section drawing indicating foundation, wall, floor, and roof
construction?,,,_ /
10. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling
joists, roof rafttrs or joists or trusses?
Yes
11. Does the building section drawing or other detail include the method ofpositive connection of
all columns and beams?
Yes !�
12. Does the elevation plan indicate the height of the building or proposed addition from the
undisturbed grade to the midpoint between the ridge and eave of a gable or shed rooforthe
top of a flat roo (Building height measurement usually not to exceed 25 feet)
Yes
13. Does the plan include any stove or zero clearance fireplace planned for installation including
make and model and Colorado Phase certifications or phase II EPA certification?
Yes No
3
14. Does the plan include a masonry fireplace including a fireplace section indicating design to
comply with the IRC?
Yes No
15. Does the plan include a window schedule or other verification that egress/rescue windows
from sleeping ropoms and/or basements comply with the requirements of the IRC?
Yes flrl.4 No
16. Does the plan include a window schedule or other verification that windows provide natural
light and ven ilation for all habitable rooms?
Yes No
17. Do the plans indicate the location of glazing subject to human impact such as glass doors,
glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as
a walking\surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures
and specify afety glazing for these areas?
Yes /I//j)No
18. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters
indicated on the plan?
Yes 409. No
19. Do you understand that if you are building on a parcel of land created by the exemption
process or the subdivision process, are building plans in compliance with all plat notes and/or
covenants?,,
Yes V No
20. Do you understand that if you belong to a homeowners association, it is your responsibility
to obtain written permission from the association, if required by that association, prior to
submitting an application for a building permit? The building permit application will not
be accepted wi out it.
Yes 1 No
21. Will this be the onlxesidential structure on the parcel?
Yes
No If no -Explain:
22. Have two (2) com a sets of construction drawings been submitted with the application?
Yes
23. Do you understand that the minimum dimension a home can be on a lot is 20ft.wide and 20ft.
long?
Yes f No
4
24. Have you designed or had this plan designed while considering building and other
construction de requirements?
Yes No
25. Do your plans comply with all zoning rules and regulations in the County related to your
propertieszon district?
Yes i� No
26. Does the plan accurately indicate what you intend to construct and what will receive a final
inspection by e Garfield County Building Department?
Yes 1 No
27. Do you understand that approval for design and/or construction changes are required prior to
the applicatio of these changes?
Yes No
28. Do you understand that the Building Department will collect a "Plan Review" fee from you
at the time of application submittal and that you will be required to pay the "Permit Fee" as
well as any "Road Impact" or "Septic System" fees required, at the time you pick up your
building pe ?
Yes a No
29. Are you aware that you must call in for an inspection by 3:30 the business day before
the requested inspection in order to receive it the following business day? Inspections
will be made from 7:30 a.m. to 3:30 p.m. Monday through Friday. Inspections are to be
called in to 384-5003.
Yes i No
30. Are you aware that requesting inspections on work that is not ready or not accessible will
result in a $5,00 re -inspection fee?
Yes t No
31. Are you aware that you are required to call for all inspections required under the IRC
including approval on a final inspection prior to receiving a Certificate of Occupancy and
occupancy of the building?
Yes No
32. Are you aware that the Permit Application must be signed by the Owner or a written
authority being given for an Agent and that the party responsible for the project must comply
with the IRC?
Yes No
5
33. Are you aware that prior to submittal of a building permit application you are required to
show proof of a driveway access permit or obtain a statement from the Garfield County Road
& Bridge Department stating one is not necessary? You can contact the Road & Bridge
Department at 6 -8601.
Yes No
34. Do you understand that you will be required to hire a State of Colorado Licensed Electrician
and Plumber to perform installations and hookups, unless you as the homeowner are
performing the work? The license number of the person performing the work will be
required at time of plicable inspection.
Yes No
35. Are you aware, that on the front of the Building Permit Application you will need to fill in
the Parce111111111111k Number for the lot you are applying for this permit on prior to submittal
of a building permit application? Your attention in this is appreciated.
Yes No
36. Do you know that the local fire7t may require you to submit plans for their review of
fire safety issues? Yes No (please check with the
building department about this requirement)
37. Do you understand that if you are planning on doing any excavating or grading to the
property prior to issuance of a building permit that you will be required to obtain a grading
permit?
Yes l/
1[ hereby acknowledge that I have read, understand and answered these questions to the
best of my abilit
Siufiature of Ow
er
Phone: 9R? 3 4/6-7
(days);
Date
9 i7 /1/
Project Name: /6-!i//71/6--/4
Project Address: 0._.5-0C-) %G`',C /-,may �� ,Qi-)
(evenings)
Notes: If you have answered "No" on any of the questions, you may be required to provide this
information at the request of the Building Official prior to beginning the plan review process. Delays
in issuing the permit are to be expected. Work may not proceed without the issuance of a permit. If
it is determined by the Building Official that additional information is necessary to review the
application and plans to determine minimum compliance with the adopted codes, the application
6
may be placed behind more recent applications for building permits in the review process and not
reviewed until required information has been provided and the application rotates again to first
position for review, delay in issuance of the permit or delay in proceeding with construction.
BpminregFeb2005
7
GARFIELD COUNTY
BUILDING REQUIREMENTS
Codes: 2003 IRC, IBC, IFGC, IMC, IPC,
Setbacks: Check subdivisions and zone district for setback requirements.
Snowload: 40PSF up to 7000ft. elevation.
50PSF 7001 to 8000ft.
75PSF 8001 to 9000ft.
100PSF 9001 to 10000ft.
Seismic design category: B
Weathering probability for concrete: Severe
Termite infestation probability: None to slight
Wind speed: 90mph
Decay probability: None to slight
Wind Exposure: B (kr C (see section R301.2.1.4)
Frost Depth: 36in. to 8000ft. elevation. 42in. 8001 and above.
Winter Design Temperature: Minus 2 to 7000ft.; minus 16 over 7000ft.
elevation.
Air Freezing Index: 2500deg F -days to 7000ft.; over 7000ft. to be determined by
Building Official.
Ice shield under-layment required.
Mean Annual temp.: Variable
Insulation: Maximum glazing U factor: 0.50
Minimum R -Values:
Ceilings/roofs R values are: R-30 stick built
structures. R-38 log construction and steel
rafter construction.
Walls R values are R-19 wood frame; R-19
cavity R-3 sheathing steel studs.
• Floors R -values are R-19.
• Basement wall R -values are R-10 below
grade, R-19 above grade.
• Slab perimeter R -value and depth is R-
10/36in.
■ Crawl space wall R -values are R-10 below
grade and R-19 above grade
If floors over crawl spaces are not insulated, the crawl space walls must be
insulated. Basement wall must be insulated to frost depth. Common walls
garage to house must have R-19 insulation. Common ceiling/floor garage
to house must have R-19. Take precautions to protect plumbing in these
areas.
PLAN REVIEW CHECKLIST
Applicant 1V1 cr i,(l0-LZ Date 16 ` Ocp
Building
Engineered Foundation
Driveway Permit C (j
Surveyed Site Plan
4Septic Permit and Setbacks
`---Grade/Topography 30%
Attach Residential Plan Review List
-71V>[inimum Application Questionnaire
Subdivision Plat Notes
kis Fire Department Review
✓Valuation Determination/Fees
J d Line Plans/Stamps/Sticker IA ach Conditions
Application Signed
✓ Pan Reviewer To Sign Application
L Parcel/Schedule No.
tit 40# Snowload Letter- Manf. Hms.
k. Soils Report
GENERAL NOTES:
Planning/Zoning
Property Line Seth , cks
30ft Stream Se i acks
Flood Plain
Building eight
Zoning ign-off
Road pact Fees
HO : 1 RC Approval
Gr . de/Topography 40%
anning Issues
Subdivision Plat Notes
P.O. Box 6030, Snowmass Village, CO 81615
Phone 970-923-3454 Fax 970-923-3458
To:
Benson Design &
Building, Inc.
G r , Sul ivG- From: C
Fax:
Phone: Date: ST/
Re:
CC:
GI Urgento� ew 0 Please Comment ❑ Please Reply 0 Please Recycle
• Comments:
I d ONI01108 NOIS30 NOSN39 Ildti H 9002 '8P0111
a i its ub iu: ed,aI'lese>t tng�neer i.ng
dY 10• Luup 11 JIHMI oCIY3U11 VE0IUIY DUILI/111U
1
57Ue4. J /'/'/3
1
urU.Ltl u r. °•
-.-"
. . 11. ••.
.SiAAgp LI ,
Ny.lbt'b4°0TM--L'•i0-tig puariV
Z •dRecCaz'.0Nime May.18. 1:05PM
ONiO11Na 01S34 NOSN38 Wd171:9 9002 '81'001
STATE ELECTRICAL BOARD
INSPECTION REPORT / CORRECTION NOTICE
Date Rec. /2-1/4 PERMIT #
Contractor/Home Owner:
Address: AA efL KtEY
TYPE OF INSPECTION:
Partial Rough in Underground Final
ACTION: Accepted Rejected Remarks
REINSPECTION FEE
Comments or Corrections:
e70 n- I �
a3Q, o�
-zew �� 9� -�Ifywe sem.ie Q06s-rtervOc-
Inspector's Name
Phone # Date /2/b4 b
FORMS:EBINSP NOTICE.DOC
No
dI► 1• /
Job Addre/ s � .�
Owner ■ , «. ,� 4 . _' 1
Contractor 1• /
Setbacks: Front
Assessor's Parcel No c2/(7 - 3(1y a7~a 11.
Date s/ e6
BUILDING �I RMIT RD Mi ,t,0 Kicjeee ci •
Elba/ /O Id-LOC./2 1
Address15%��
� -C .47 S #5, /! � Phone
Address ce-J`�- Phone # °-3 - 3 f V
RH LH Zoning
Rear
Sd Is Test V
Footing - bid 9 rza (.5,L'1-$
Foundation 4.,`-2 Z
Grout
Underground Plumbingq//4
Rough Plumbing d�
Framing % -/-06 �J1?
Insulation /2
Roofing
Drywall J -/6 107
Gas Piping
EXTERIOR
Address No.
Drainage
Decks -support & clearance to wood
Decks -stairs & rails
Exterior locks
Flashing around doors & windows
Insect screens
INTERIOR
GARAGE
Fire wall separation
Service doors -1W min.
Door (20 min.) w/auto closer -1W min
Mech. equip. 18" above floor
No opening into sleeping area
BASEMENT -CRAWL AREA
Access
Insulation
Headroom/Stairs
Ventilation
INSPECTIONS
Weatherproofing
Mechanical
Electrical Rough (State) 12
Electrical Final (State)
Final 9-)-O7 !Checklist Co feted?
Certificate Occupancy # _ (14
Date
Septic System # t -)(4 -
Other
NOTES
Date —
Final �-- --��
(continue on back)
FINAL CHECKLIST
MECHANICAL ROOM STAIRWAYS .
Boiler Headroom (8'8")
Hot water Falling & guardrails
F.A. gadoII Width
Floor drain Rise & run
Clearance KITCHEN
Air con. system Clearance above grill
Exhaust fan
Broiler exhaust (1 hr. chase)
Gas piping, valves BEDROOMS
LPG Drain Egress
FIREPLACE/STOVE Smoke detector
Clearance to combustibles BATHROOMS
Termination of chimney Exhaust fan
Combustion air Shatterproof glass
Hearth (12" or 20" on sides) OTHER
Glass doors
Certified by:
Hot water heater
Combustion air
REMARKS
INSPECTION WILL NOT BE MADE UNLESS
THIS CARD IS POSTED ON THE JOB
24 HOURS NOTICE REQUIRED FOR INSPECTIONS
NOTICE REQUIRED FOR INSPECTIONS
BUILDING PERMIT
GARFIELD COUNTY, COLORADO
Date Issued 0oned Area Permit No
AGREEMENT
In consideration of the issuance of this permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location; construction and erection of the proposed
structure for which this permit is granted, and further agrees that if the above said regulations
are not fully complied with in the zoning, location, erection and construction of the above
described structure, the permit may then be revoked by notice from the County Building
Inspejy and IMMEDIATELY BECOME NULL AND VOID.
rg
Address or Legal Description i.0
Owner 1�j64111 Contractor
Use
This Card Must Be Posted So It is Plainly Visible From The Street Until Final Inspection.
INSPECTION RECORD
Footing 141,10544 6 v`ar
Driveway
///41
Foundation - 22).616a-
Underground Plumbing 4//g
Insulation la-ra-vG
Rough Plumbing/v/4
Drywall /6-07
Chimney & Vent ili/R
Electric Final (by State Ir on) if IN
Gas Piping /v/A
Final 9- 7- , � ,e -a --
Electric Rough (By State In. ) 04%
i �
,
Septic Final /1/A_
Framing/2-/-06��
�
(To include Roof in place and Win ows
and Doors installed).ti,;p
Notes: �fj�
/'�4%
limmiimiiimommiiiimmi
ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING -
WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND.
THIS PERMIT IS NOT TRANSFERABLE
For Inspections Call 384-5003 108 8th Street Glenwood Springs, Colorado
APPROVEDDO NOT DESTROY THIS CARD
Date50y
F PLACED OUTSIDE - CO ER WHCLEAR PLASTIC
Parcel Detail Page 1 of 4
Garfield County Assessor/Treasurer
Parcel Detail Information
Assessor/Treasurer Property Search 1 Assessor Subset Query 1 Assessor Sales Search
Clerk ..,& Recorder Reception Search
Basic Building Characteristics 1 Tax Information
Parcel Detail I Value Detail 1 Sales Detail I Residential/Commercial Improvement Detail
Land Detail I Photographs
Tax Area
001
Account Number
R020153
Parcel Number
211934407012
Mill Levy
69.797
Owner Name and Mailing Address
NIGHTINGALE, JOEL E. & BONNIE L.
500 MEL REY RD
GLENWOOD SPGS, CO 81601-2613
Legal Description
SECT,TWN,RNG:34-5-89 SUB:WESTERN HILLS
SUB. BLK:7 LOT:10 DESC: EXCEPT ELY 15'
BK:0530 PG:0882 BK:0499 PG:0366 BK:0478
PG:0273 BK:0475 PG:0332 BK:0805 PG:0660
Location
Physical Address:
500 MEL RAY RD GLENWOOD SPRINGS
Subdivision:
WESTERN HILLS SUB.
Land Acres:
0
Land Sq Ft:
18,371
Section
Township
Range
34
5
89
Property Tax Valuation Information
[1
11
11
11
http://www.garcoact.comlassessor/parcel.asp?ParcelNumber=211934407012 12/3/2007
Parcel Detail Page 2 of 4
I� Actual Value Assessed Value
Land:
Improvements:
Total:
130,000
227,440
357,440
10,350
18,100
28,450
Sale Date:
Sale Price:
6/7/1991
114,000
Basic Building Characteristics
Number of Residential
Buildings:
Number of Comm/Ind
Buildings:
1
0
1
1
Residential Building Occurrence 1 Characteristics
I
TOTAL HEATED AREA:
2,044
ABSTRACT CODE:
SINGLE FAM.RES-
IMPROVEMTS
ARCHITECTURAL STYLE:
BI LEVEL
EXTERIOR WALL:
MASONITE
EXTERIOR WALL:
BRICK VEN
ROOF COVER:
PREFAB MET
ROOF STRUCTURE:
GABLE
INTERIOR WALL:
AVG PANEL
INTERIOR WALL:
DRYWALL
FLOOR:
CARPET
FLOOR:
MIN PLYWD
HEATING FUEL:
GAS
HEATING TYPE:
FORCED AIR
STORIES:
STORIES 1.0
BATHS:
2
ROOMS:
8
UNITS:
1
BEDROOMS:
4
YEAR BUILT:
1973
Tax Information
http://www.garcoact.comlassessor/parcel.asp?ParcelNumber=211934407012 12/3/2007
Parcel Detail Page 3 of 4
Tax Year
Transaction Type
Amount
2006
Tax Payment: Second Half
($793.24)
2006
Tax Payment: First Half ($793.24)
2006
Tax Amount
$1,586.48
2005
Tax Payment: Second Half
($795.17)
2005
Tax Payment: First Half
($795.17)
2005
Tax Amount
$1,590.34
2004
Tax Payment: Second Half
($822.11)
2004
Tax Payment: First Half
($822.11)
2004
Tax Amount
$1,644.22
2003
Tax Payment: Second Half
($735.22)
2003
Tax Payment: First Half
($735.22)
2003
Tax Amount
$1,470.44
2002
Tax Payment: Second Half
($775.92)
2002
Tax Payment: First Half
($775.92)
2002
Tax Amount
$1,551.84
2001
Tax Payment: Second Half
($783.10)
2001
Tax Payment: First Half
($783.10)
2001
Tax Amount
$1,566.20
2000
Tax Payment: Second Half
($754.58)
2000
Tax Payment: First Half
($754.58)
2000
Tax Amount
$1,509.16
1999
Tax Payment: Second Half
($707.37)
1999
Tax Payment: First Half
($707.37)
1999
Tax Amount
$1,414.74
Top of Page
Assessor Database Search Options 1 Treasurer Database Search Options
Clerk & Recorder Database Search Options
Garfield County Home Page
The Garfield County Assessor and Treasurer's Offices make every effort to collect and maintain
accurate data. However, Good Turns Software and the Garfield County Assessor and Treasurer's Offices
are unable to warrant any of the information herein contained.
http://www.garcoact.com/assessor/parcel.asp?ParcelNumber=211934407012 12/3/2007
NO. 'Cia(ca
Garfield County
Building & Sanitation Department
108 8th Street, Suite #401 Glenwood Springs, Co. 81601
Office- 945-8212 Inspection Line- 384-5003
Job Address C056 -o 144
)46‘.40-vtri Ei60,
664- ft, eeeycx / 4.4-04,S
Nature of Work Buildin• Permit I . 1tt c2111- 3CA/ ?-6,
! t
Use of Building
Owner
Contractor
Amount of Permit $ 5-9 6 . oD-6
Date
Clerk