HomeMy WebLinkAboutApplication-PermitGarfield County
Building & Sanitation Department
108 8`h Street, Suite #401 Glenwood Springs, Co. 81601
Office- 945-8212 Inspection Line- 384-5003
Job Address
NO. Gq 1cj
Nature of Work
0) -395 -/o/ -0q -o/
Use of Building " 1 1 y dLGC( fie 3
Owner - K ! ± J
Contractor D2414- 3
Amount of Permit $pT PO. 5 3
Date
✓ # 13a6.s a- c
38O %- Os Clerk v I
(jf oZd1D
J
1
GARFIELD COUNTY BUILDING PERMIT APP LI CATION
108 8 Street. Suite 401. Glenwood Sprtngs, CO 81801
Phone: 970-945-8212 / Fen: 970-384-3470 / Inspection Line: 970-584-5003
Permit No 19 f 1
Parcel/Schedule No: 3Q 5 10 r G9 01S'
AGREEMENT
PERMISSION I5 HEREBY GRANTED TO THE APPLICANT AS OWNER. CONTRACTOR AND/OR THE AGENT OF THE CONTRACTOR OR OWNER 70 CONSTRUCT
THE STRUCTURE AS DETAILED ON PUNS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT
IN CONSIDERATION OF THE ISSSUANCE OF THIS PERMIT. THE SIGNER HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND
USE REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN LN 30.28.201 CRS AS AMENDED THE SIGNER FURTHER AGREES
THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPILED WITH TN THE LCOATION, ERECTION. CONSTRUCTION. AND USE OF THE
ABOVE DESCRIBED STRUCTURE, THE PERMIT MAY BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT SHALL BECOME
NULL AND VOID THE ISSUANCE OF A PERMT BASED UPON PLANS. SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE BUILDING OFFICIAL
FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS M SAID PLANS SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING
BUILDING OPERATION BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF THS CODE OR ANY OTHER ORDINANCE OR REGULATION OF
THIS JURISDICTION THE REVIEW OF SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE
AN ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABLrIIES BY GARFIELD COUNTY FOR ERRORS OMISSIONS OR DISCREPENCES THE RESPONSI
BILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICIALLY WITH THE ARTICTECT DESIGNER BUILDER,
AND OWNER. COMMENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS LNTEREST
I HEREBY ACKNOWLEDGE THAT 1 HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE IINITIALI
7
of y5 k--1igr, �� •fir. S. Co �sr6° r
1 Lot No: Block No: Subd. / Exem don'
les`� SPe//WoehXetf GRYC 9h
2
Qwrier:
obert+-Aimy 5toL�
Address
5785 S LC6HN
Ph: 303. 762 977t,
Wk
fi'0 32.0 0767.
3
Contractor
OCoc Gen sT&Ucr41
Address: 6a;Val'a," L'.ijd'4c,P1-D
Ofg7 �IFttnd 1 -Pr G.S
P lot (45 -665`s' 379-2731
Ll o
�''' AA 11-
.wl //
4
Arcbitect�glneer
Ft.
Address.
Ph ,+� _ ,.1
7
Lic. No. 0
3
Sq. of Building:
ZZ40
Sq Ft. of Lot-
S9igzg14
Height.(
2z
No. of Floors.
l
U
I ^ 0.X�' A 4
Use or ullding: ) Ahajiwa.CZ%)
94 Va+
,(13
7
Descrl a k:
bL D4.w�- (((JJJ
tt,
U
8
Class of Work: New ❑ Alteration o Remove
LI Addition 7 Move
9
10
Gyrdge.
C(
❑ Sir gle
Carport: 0 Single
U Double
Doub
u Driveway Permit ,7 On -Site Sewage
Disposal
Stte Plan
11
Valuation of Work: S3� 0�7 Adjusted Valuations: S cirrip_r�
I/
12
Special Conditions:�/02,1 p.�j`v��
`y A% /�I 1 U
/`-' Ow � TICEOr
cC�� l,rp
(J ti
MUST BE
CONSTRUCTION
OR, IF
FOR A/
COMMENCED.
THIS
CORRECT ALL
WILL BE
OR NOT THE
AUTHORITY
STATE OR
//
�(j�, �'�� /'
�SR.U1e�l. V / .
Plan Check Fee: /
917' /
�/ �O�l/J��
(,1 u'i-t
Permit Fee:
15-03.315
A SEPARATE ELECTRICAL PERMIT I5 REQUIRED AND
ISSUED BY THE STATE OF COLORADO
THIS PERMIT BECOMES NULL AND VOID IF WOW( OR
AUTHORIZED IS NOT COMMENCED WITHLN 180 DAYS.
CONSTRUCTION OR WORK I5 SUSPENDED OR ABANDONED
PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS
i HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED
APPLICATION AND KNOW THE SAME TO BE TRUE AND
PROVISIONS OF LAWS GOVERNING THIS TYPE OF WORK
COMPLETED WITHIN WHETHER SPECIFIED HEREIN
GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE
TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER
LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE
OF Cs NSTRU ON ``))rnI I,
,A / �,j?jlt' 7–fg-7�
Total Fee: ., Dated Permit Issued:
_
Z�' o /� 3 -4-- 13x.6 , 5 )— 3801 • Es
upConst. Type:
0 CC /croup:
<`.
Zoning:
I(_J
)
Setbacks:
No. & Fee:
5••
ivtrrn-rf-force--m-0.
,
G
y,IISSDS
I. 4r
3a6
1``
••(I OWNER Ln DATE
iL /TIL/o
' 15-r1` o cry JPLNG
:.-
., • -•i DEFT. (�`_c;/33-(3.5)—
• ••/DATE APPROVAL/DATE
AGREEMENT
PERMISSION I5 HEREBY GRANTED TO THE APPLICANT AS OWNER. CONTRACTOR AND/OR THE AGENT OF THE CONTRACTOR OR OWNER 70 CONSTRUCT
THE STRUCTURE AS DETAILED ON PUNS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT
IN CONSIDERATION OF THE ISSSUANCE OF THIS PERMIT. THE SIGNER HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND
USE REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN LN 30.28.201 CRS AS AMENDED THE SIGNER FURTHER AGREES
THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPILED WITH TN THE LCOATION, ERECTION. CONSTRUCTION. AND USE OF THE
ABOVE DESCRIBED STRUCTURE, THE PERMIT MAY BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT SHALL BECOME
NULL AND VOID THE ISSUANCE OF A PERMT BASED UPON PLANS. SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE BUILDING OFFICIAL
FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS M SAID PLANS SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING
BUILDING OPERATION BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF THS CODE OR ANY OTHER ORDINANCE OR REGULATION OF
THIS JURISDICTION THE REVIEW OF SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE
AN ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABLrIIES BY GARFIELD COUNTY FOR ERRORS OMISSIONS OR DISCREPENCES THE RESPONSI
BILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICIALLY WITH THE ARTICTECT DESIGNER BUILDER,
AND OWNER. COMMENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS LNTEREST
I HEREBY ACKNOWLEDGE THAT 1 HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE IINITIALI
7
The following items are required by Garfield County for a final inspection:
1. A final Electrical Inspection from the Colorado State Electrical Inspector;
2. Permanent address assigned by Garfield County Building Department posted where readily
visible from access road;
3. A finished roof, a lockable house, complete exterior siding, exterior doors and windows
installed, a complete kitchen with cabinets, a sink with hot & cold running water, non-absorbent
kitchen floor coverings, counter tops and finished walls, ready for stove and refrigerator, all
necessary plumbing;
4. All bathrooms must be complete, with washbowl, tub or shower, toilet stool, hot and cold
running water, non-absorbent floors and walls finished and a privacy door;
5. All steps outside or inside over three (3) steps must have handrails, guard rails on balconies or
decks over 30" high constructed to all IBC and IRC requirements;
6. Outside grading done to where water will detour away from the building;
7. Exceptions to the outside steps, decks and grading may be made upon the demonstration of
extenuating circumstances, i.e. weather, but a Certificate of Occupancy will not be issued until
all the required items are completed and a final inspection made;
8. A final inspection sign off by the Garfield County Road & Bridge Department for driveway
installation, where applicable; as well as any final sign off by the Fire District, and/or State
Agencies where applicable.
A CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL ALL THE
ABOVE ITEMS HAVE BEEN COMPLETED.
****CANNOT OCCUPY OR USE DWELLING UNTIL A CERTIFICATE OF OCCUPANCY
(C.O.) IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE
CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING
PREMISES UNTIL ABOVE CONDITIONS ARE MET.
I understand and agree to abide by the above conditions for occupanck use and the issuance of a
Certificate of Occupancy for the dwelling under building permit # "I �1 1 9
ii -Kg 6
Signature Date
Bpappl icationfeb2006
Applicant
Address
VALUATION/FEE DETERMINATION
Date 5- ho
-
q sit
Finished (Livable Area):
Main
Upper
Lower
Other
Total Square Feet ZZ(QQ p
Valuation
Basement:
Unfinished
Conversion of Unfinished to Finished
Plan Check Fee for Conversion
Valuation
Garage:
Crawl Space:
Valuation Wel-
ke t ( g
Valuation
Decks/Patios:
Covered
Valuation
Open
Valuation
Zcn 124
Total Valuation
Subdivision 7244144-(
Lot/Block
Contractor .Devykco
cADILLt
/6'0, 774' Zo
4(n
/9c 9',4.
GARFIELD COUNTY BUILDING AND PLANNING
970-945-8212
MINIMUM APPLICATION REQUIREMENTS
For
SINGLE FAMILY DWELLING CONSTRUCTION
Including
NEW CONSTRUCTION
ADDITIONS
ALTERATIONS
And
MOVED BUILDINGS
In order to understand the scope of the work intended under a permit application and expedite the
issuance of a permit it is important that complete information be provided. When reviewing a plan
and it's discovered that required information has not been provided by the applicant, this will result
in the delay of the permit issuance and in proceeding with building construction. The owner or
contractor shall be required to provide this information before the plan review can proceed. Other
plans that are in line for review may be given attention before the new information may be reviewed
after it has been provided to the Building Department.
Please review this document to determine if you have enough information to design your
project and provide adequate information to facilitate a plan review. Also, please consider
using a design professional for assistance in your design and a construction professional for
construction of your project. Any project with more than ten (10) occupants requires the plans
to be sealed by a Colorado Registered Design Professional.
To provide for a more understandable plan in order to determine compliance with the building,
plumbing and mechanical codes, applicants are requested to review the following checklist prior to
and during design. Applicants are required to indicate appropriately and to submit the
completed checklist at time of application for a permit.
Plans to be included for a Building Permit, must be on drafting paper at least 18"x24" and
drawn to scale.
1
•
Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with
decks, balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line
and original grade. A section showing in detail, from the bottom of the footing to the top of the roof,
including re -bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation,
sheeting, house -rap, (which is required), siding or any approved building material. Engineered
foundations may be required.
A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be
designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. wind
speed, wind exposure B or C, and a 36 inch frost depth.
All sheets to be identified by number and indexed. All of the above requirements must be met or
your plans will be returned.
All plans submitted must be incompliance with the 2003 IRC.
Is a site plan included that identifies the location of the proposed structure or addition and
distances to the property lines from each corner of the proposed structure(s) prepared by a
licensed surveyor and has the surveyors signature and professional stamp on the drawing?
Properties with slopes of 30% or greater must be shown on the site plan. (NOTE
Section: 106.2) Any site plan for the placement of any portion of a structure within 50 ft.
of a property line and not within a previously surveyed building envelope on a
subdivision final plat shall be prepared by a licensed surveyor and have the surveyor's
signature and professional stamp on the drawing. Any structure to be built within a
building envelope of a lot shown on a recorded subdivision plat shall include a copy of
the building envelope as it is shown on the final plat with the proposed structure located
within the envelope.
Yes
2. Does the site plan also include any other buildings on the property, setback easements and
utility easements? Please refer to Section 5.05.03 in the Garfield County Zoning Resolution
if the property you are applying for a building permit on is located on a corner lot. Special
setbacks do apply.
Yes
3. Does the site plan include when applicable the location of the I.S.D.S. (Individual Sewage
Disposal System) and the distances to the property lines, wells (on subject property and
adjacent pr erties), streams or water courses?
Yesl
4. Does the site plan indicate the location and direction of the County or private road accessing
the property%
Yes !i
5. Do the plans include a foundation plan indicating the size, location and spacing of all
reinforcing steel in accordance with the IRC or per stamped engineered design?
Yes
6. Do the plans indicate the location and size of ventilation openings for under floor crawl
spaces and the clearances required between wood and earth?
Yes
7. Do the plans indicate the size and location of ventilation openings for the attic, roof joist
spaces and so ts?
Yes
8. Do the plans include design loads as required by Garfield County for roof snow Toads, (a
minimum of 40 pounds per square foot up to & including 7,000 feet above sea level), floor
loads and wild loads?
Yes ✓
9. Does the plan include a building section drawing indicating foundation, wall, floor, and roof
construction?�
Yes
10. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling
joists, roof rafjsrs or joists or trusses?
Yes ✓✓
11. Does the building section drawing or other detail include the method ofpositive connection of
all columns and beams?
Yes �/
12. Does the elevation plan indicate the height of the building or proposed addition from the
undisturbed grade to the midpoint between the ridge and eave of a gable or shed roof or the
top of a flat r . (Building height measurement usually not to exceed 25 feet)
Yes
13. Does the plan include any stove or zero clearance fireplace planned for installation including
make and model and Colorado Phase II certifications or phase II EPA certification?
Yes �/ No
3
14. Does the plan include a masonry fireplace including a fireplace section indicating design to
comply with the IRC?
Yes /ti/fr No
15. Does the plan include a window schedule or other verification that egress/rescue windows
from sleeping rooms and/or basements comply with the requirements of the IRC?
Yes � No
16. Does the plan include a window schedule or other verification that windows provide natural
light and ventilation for all habitable rooms?
Yes No
17. Do the plans indicate the location of glazing subject to human impact such as glass doors,
glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as
a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures
and specify safe lazing for these areas?
Yes No
18. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters
indicated on the plan?
Yes firnir No
19. Do you understand that if you are building on a parcel of land created by the exemption
process or the subdivision process, are building plans in compliance with all plat notes and/or
covenants?
Yes L/ No
20. Do you understand that if you belong to a homeowners association, it is your responsibility
to obtain written permission from the association, if required by that association, prior to
submitting an application for a building permit? The building permit application will not
be accepted wi I�ou it.
Yes /,• n- No
21. Will this be the only residential structure on the parcel?
Yes ' No If no -Explain:
22. Have two (2) complete sets of construction drawings been submitted with the application?
Yes
23. Do you understand that the minimum dimension a home can be on a lot is 20ft.wide and 20ft.
long?
Yes No
4
24. Have you designed or had this plan designed while considering building and other
construction co a requirements?
Yes No
25. Do your plans comply with all zoning rules and regulations in the County related to your
properties zone dist ' t?
Yes No
26. Does the plan accurately indicate what you intend to construct and what will receive a final
inspection by the Garfield County Building Department?
Yes No
27. Do you understand that approval for design and/or construction changes are required prior to
the applicatioryof these changes?
Yes ✓✓ No
28. Do you understand that the Building Department will collect a "Plan Review" fee from you
at the time of application submittal and that you will be required to pay the "Permit Fee" as
well as any "Road Impact" or "Septic System" fees required, at the time you pick up your
building permit?
Yes No
29. Are you aware that you must call in for an inspection by 3:30 the business day before
the requested inspection in order to receive it the following business day? Inspections
will be made from 7:30 a.m. to 3:30 p.m. Monday through Friday. Inspections are to be
called in to 38003.
Yes c/ No
30. Are you aware that requesting inspections on work that is not ready or not accessible will
result in a 550.0 re -inspection fee?
Yes r/ No
31. Are you aware that you are required to call for all inspections required under the IRC
including approval on a final inspectionrp for to receiving a Certificate of Occupancy and
occupancy ofbuilding?
Yes No
32. Are you aware that the Permit Application must be signed by the Owner or a written
authority being given for an Agent and that the party responsible for the project must comply
with the IRC
Yes No
5
33. Are you aware that prior to submittal of a building permit application you are required to
show proof of a driveway access permit or obtain a statement from the Garfield County Road
& Bridge Department stating one is not necessary? You can contact the Road & Bridge
Department at 625-8E}�1,,_
Yes /V ft No
34. Do you understand that you will be required to hire a State of Colorado Licensed Electrician
and Plumber to perform installations and hookups, unless you as the homeowner are
performing the work? The license number of the person performing the work will be
required at time applicable inspection.
Yes No
35. Are you aware, that on the front of the Building Permit Application you will need to fill in
the Parcel Number for the lot you are applying for this permit on prior to submittal
of a building papplication? Your attention in this is appreciated.
Yes ermi No
36. Do you know that the local fire distric may require you to submit plans for their review of
fire safety issues? Yes No (please check with the
building department about this requirement)
37. Do you understand that if you are planning on doing any excavating or grading to the
property prior to issuance of a building permit that you will be required to obtain a grading
permit?
Yes
I hereby acknowledge that I have read, understand and answered these questions to the
g best of my ability.
Signature of Owner Date
Phone: 379 -Z 73 `f (days);
qqs 54t
(evenings)
Project Name: JCEL,
dek 1R , 4Nta4,R_
Project Address:
Pehtst64.
Notes: If you have answered "No" on any of the questions, you may be required to provide this
information at the request of the Building Official prior to beginning the plan review process. Delays
in issuing the permit are to be expected. Work may not proceed without the issuance of a permit. If
it is determined by the Building Official that additional information is necessary to review the
application and plans to determine minimum compliance with the adopted codes, the application
may be placed behind more recent applications for building permits in the review process and not
reviewed until required information has been provided and the application rotates again to first
position for review, delay in issuance of the permit or delay in proceeding with construction.
BpminreqFeb2005
7
April 19, 2006
Fax:3037683200
Apr 19 2006 7:05 P.01
RECEIVED
APR 1 9 2006
GARF, ^I d
BUIlD1At d PpNN NG
Garfield County 13ding Permits
Attn: Teresa
Sent VIA Fax 97 384-3470
This is m authoriz Gary Heise', Dante Construction to obtain our building permit for
lot #18, Springri . _ Reserve.
bert L. Stull
Stull
Applicant
PLAN REVIEW CHECKLIST
Building
iyiigineered Foundation
/OA Driveway Permit
Site Plan
a ft Septic Permit and Setbacks
ade/Topography 30%
4 - Attach Residential Plan Review List
c/ Minimum Application Questionnaire
Date l�
✓ Subdivision Plat Notes
et Fire Department Review z( 3SOS,Cr
/Valuation Determination/Fees
Red Line Plans/Stamps/Sticker
Attach Conditions
Application Signed
clan Reviewer To Sign Application
P 1/Schedule No.
Cl A- 40# Snowload Letter- Manf. Hms.
oils Report
GENERAL NOTES:
Planning/Zoning
Property Line Setba s
30ft Stream Setb. ks
Flood Plain
Building Hei t
Zoning Sipb-off
Road Iryipact Fees
RC Approval
de/Topography 40%
Tanning Issues
Subdivision Plat Notes
Parcel Detail Page 1 of 3
Garfield County Assessor/Treasurer
Parcel Detail Information
Assessor/Treasurer Propel Search I Assessor Subset Query 1 Assessor Sales Search
Clerk & Recorder Reception Search
Basic Building Characteristics 1 Tax Information
Parcel Detail 1 Value Detail 1 Sales Detail 1 Residential/Commercial Improvement Detail
Land Detail 1 Photographs
Tax Area
Account Number
Parcel Number
Mill Levy
008
R042633
239510109018
63.502
Owner Name and Mailing Address
STULL, ROBERT L & AMY R
5185 SOUTH LOGAN
GREENWOOD VILLAGE, CO 80121
Legal Description
SECT,TW N,RNG:10-7-89
SUB:SPRINGRIDGE RESERVE PUD, PHASE
1 LOT:18 PRE:R042100 BK:1730 PG:245
RECPT:683135 BK:1720 PG:770
RECPT:681083 BK:1720 PG:768
RECPT:681082 BK:1720 PG:766
RECPT:681081 BK:1720 PG:764
RECPT:681080 BK:1720 PG:761
RECPT:681079 BK:1720 PG:759
RECPT:681078 BK:1720 PG:757
RECPT:681077 BK:1720 PG:731
RECPT:681076 BK:1720 PG:710
RECPT:681075 BK:1720 PG:702
RECPT:681073 BK:1720 PG:696
RECPT:681072 BK:1720 PG:693
RECPT:681071 BK:1720 PG:673
htrn•/Li,a,.v aarrnart rnm/accrccnr/narrel acn7ParrelNnmher=239510109018
10/20/2006
Parcel Detail Page 2 of 3
RECPT:681069 BK:1661 PG:345
RECPT:668309 BK:1652 PG:180
RECPT:666215
Location
Physical Address:
145 HIGH POINT DR GLENWOOD SPRINGS
Subdivision:
SPRINGRIDGE RESERVE PUD, PHASE 1
Land Acres:
1.376
Improvements:
0
Land Sq Ft:
0
39,000
11,310
Section
Tax Amount
Township
Range
10
7
89
Property Tax Valuation Information
Sale Date:
Sale Price:
9/6/2005
170,000
Basic Building Characteristics
Number of Residential
Buildings:
Number of Command
Buildings:
0
0
No Building Records Found
Tax Information
Tax Year
Actual Value
Assessed Value
Land:
39,000
11,310
Improvements:
0
0
Total:
39,000
11,310
Sale Date:
Sale Price:
9/6/2005
170,000
Basic Building Characteristics
Number of Residential
Buildings:
Number of Command
Buildings:
0
0
No Building Records Found
Tax Information
Tax Year
Transaction Type
Amount
2005
Tax Payment: Whole
($5.00)
2005
Tax Payment: Whole
(S9.52)
2005
Tax Amount
$9.52
2005
Tax Amount
$5.00
I 1 .. _On.. ,...1X7.,, ,kni--11OC1111110111
1 nilnilnf6
GVS/tV Vh
HEPWORTH - PAWLAK GEOTECHNICAL
October 12, 2005
Robert and Amy Stull
5185 South Logan Drive
Greenwood Village, Colorado 80121
Hepworrh-Pawlak Geotechnical, ]nc
5020 Council Road 154
Glenwood Springs, Colorado 81601
Phone 970-945-7988
Fax- 970-945-8454
email. hpgeo@hpgeotech.com
Job No.105 810
Subject: Subsoil Study for Foundation Design, Proposed Residence, Lot 18, Spring
Ridge II, Garfield County, Colorado
Dear Mr. and Mrs. Stull:
As requested, Hepworth-Pawlak Geotechnical, Inc. performed a subsoil study for design
of foundations at the subject site. The study was conducted in accordance with our
agreement for geotechnical engineering services to you dated September 9, 2005. The
data obtained and our recommendations based on the proposed construction and
subsurface conditions encountered are presented in this report. Hepworth-Pawlak
Geotechnical, Inc., previously performed a preliminary geotechnical study for Spring
Ridge II and reported our findings February 26, 2001, Job No. 101 126.
Proposed Construction: The proposed residence will be one story wood frame with
slab -on -grade floor. The site is shown on Figure 1. Cut depths are expected to range
between about 3 to 4 feet. Foundation loadings for this type of construction are assumed
to be relatively light and typical of the proposed type of construction.
If building conditions or foundation loadings are significantly different from those
described above, we should be notified to re-evaluate the recommendations presented in
this report.
Site Conditions: The site is vacant and appears to have been used as irrigated pasture
land. Vegetation consists of grass and weeds. The ground surface is relatively gently
rolling with grades of about 3 to 5 percent.
Subsurface Conditions: The subsurface conditions at the site were evaluated by
excavating two exploratory pits at the approximate locations shown on Figure 1. The
logs of the pits are presented on Figure 2. The subsoils encountered, below about 1/2 foot
of topsoil, consist of sandy clay down to the bottom of the pits, 6 to 6'/2 feet Results of
swell -consolidation testing performed on relatively undisturbed samples of sandy clay,
presented on Figure 3, indicate low compressibility under existing moisture conditions
Parker 303-841-7119 • Colorado Springs 719-633-5562 • Silverthome 970-468-1989
-2 -
and light loading and a low expansion potential when wetted. No free water was
observed in the pits at the time of excavation and the soils were slightly moist to moist.
Foundation Recommendations: Considering the subsoil conditions encountered in the
exploratory pits and the nature of the proposed construction, we recommend spread
footings placed on the undisturbed natural soil designed for an allowable soil bearing
pressure of 1,500 psf for support of the proposed residence. The clay soils in the area are
typically settlement prone when wetted and there could be some post -construction
foundation movement if the bearing soils become wetted. Footings should be a minimum
width of 16 inches for continuous walls and 2 feet for columns. Loose and disturbed soils
encountered at the foundation bearing level within the excavation should be removed and
the footing bearing level extended down to the undisturbed natural soils. Exterior
footings should be provided with adequate cover above their bearing elevations for frost
protection. Placement of footings at least 36 inches below the exterior grade is typically
used in this area. Continuous foundation walls should be reinforced top and bottom to
span local anomalies such as by assuming an unsupported length of at least 12 feet.
Foundation walls acting as retaining structures should be designed to resist a lateral earth
pressure based on an equivalent fluid unit weight of at least 50 pcf for the on-site soil as
backfill.
Floor Slabs: The natural on-site soils, exclusive of topsoil, are suitable to support lightly
loaded slab -on -grade construction. To reduce the effects of some differential movement,
floor slabs should be separated from all bearing walls and columns with expansion joints
which allow unrestrained vertical movement. Floor slab control joints should be used to
reduce damage due to shrinkage cracking. The requirements for joint spacing and slab
reinforcement should be established by the designer based on experience and the intended
slab use. A minimum 4 inch layer of free -draining gravel should be placed beneath
basement leve] slabs to facilitate drainage. This materia] should consist of minus 2 inch
aggregate with less than 50% passing the No. 4 sieve and less than 2% passing the No.
200 sieve.
All fill materials for support of floor slabs should be compacted to at least 95% of
maximum standard Proctor density at a moisture content slightly above optimum.
Required fill can consist of the on-site soils devoid of vegetation and topsoil.
Surface Drainage: The following drainage precautions should be observed during
construction and maintained at all times after the residence has been completed:
Job No.105 810
-3-
1) Inundation of the foundation excavations and underslab areas should be
avoided during construction. Drying could increase the expansion
potential of the soils.
2) Exterior backfill should be adjusted to near optimum moisture and
compacted to at least 95% of the maximum standard Proctor density in
pavement and slab areas and to at least 90% of the maximum standard
Proctor density in landscape areas. Free -draining wall backfill should be
capped with about 2 feet of the on-site, finer graded soils to reduce surface
water infiltration.
3) The ground surface surrounding the exterior of the building should be
sloped to drain away from the foundation in all directions. We
recommend a minimum slope of 6 inches in the first 10 feet in unpaved
areas and a minimum slope of .3 inches in the first l0 feet in pavement and
walkway areas
4) Roof downspouts and drains should discharge well beyond the limits of all
backfill.
5) Landscaping which requires regular heavy irrigation should be located at
least 10 feet from the building. Consideration should be given to the use
ofxeriscape to limit potential wetting of soils below the foundation caused
by irrigation.
Limitations: This study has been conducted in accordance with generally accepted
geoteclmical engineering principles and practices in this area at this time. We make no
warranty either express or implied. The conclusions and recommendations submitted in
this report are based upon the data obtained from the exploratory pits excavated at the
locations indicated on Figure 1 and to the depths shown on Figure 2, the proposed type of
construction, and our experience in the area. Our services do not include determining the
presence, prevention or possibility of mold or other biological contaminants (MOBC)
developing in the future. If the client is concerned about MOBC, then a professional in
this special field of practice should be consulted. Our findings include interpolation and
extrapolation of the subsurface conditions identified at the exploratory pits and variations
in the subsurface conditions may not become evident until excavation is performed. If
conditions encountered during construction appear different from those described in this
report, we should be notified at once so re-evaluation of the recommendations may be
made.
This report has been prepared for the exclusive use by our client for design purposes. We
are not responsible for technical interpretations by others of our information. As the
project evolves, we should provide continued consultation and field services during
JobNo.105 810
1
-4-
construction to review and monitor the implementation of our recommendations, and to
verify that the recommendations have been appropriately interpreted. Significant design
changes may require additional analysis or modifications to the recommendations
presented herein. We recommend on-site observation of excavations and foundation
bearing strata and testing of structural fill by a representative of the geotechnical
engineer.
If you have any questions or if we may be of further assistance, please let us know.
Respectfully Submitted,
HEPWORTH - PAWLAK GEOTECHNICAL, INC.
`Louis E. Eller
Reviewed by:
,Wrlflh11H �4
§L
��U e /;,JFa
o
a4}
LEE/djb4 /djY/os•
attachments Figure ] — Loc dp oratory Pits
Figure 2 — Logs of Exploratory Pits
Figure 3 — Swell -Consolidation Test Results
Daniel E. Hardin, P.E.
cc: Demco Construction Company — Attn: Gary Heise]
Job No. 105 810
APPROXIMATE SCALE
1"=50
1
LOT 19
\
Nit
1
6450
/
/
6450
105 810
aach
Hepworth—Powlak Geotechnical
LOCATION OF EXPLORATORY PITS
Figure 1
0
5
10
LEGEND:
PJT 1 PIT 2
WC=7.7
DD=95
WC=9.0
DD=120
TOPSOIL; organic sandy silt and clay, firm, moist, dark brown.
CLAY (CL); silty, sandy, medium stiff to very stiff, slightly moist to moist, porous, brown.
2" Diameter hand driven liner sample.
0
5
10
•
NOTES:
1. Exploratory pits were excavated on September 26, 2005 with a Cat 330 trackkhoe.
2. Locations of exploratory pits were measured approximately by pacing from features shown on the site plan
provided.
3. Elevations of exploratory pits were not measured and the logs of exploratory pits are drawn to depth.
4. The exploratory pit locations and elevations should be considered accurate only to the degree implied by the method
used.
5. The lines between materials shown on the exploratory pit logs represent the approximate boundaries between
material types and transitions may be gradual.
6. No free water was encountered in the pits at the time of excavating. Fluctuation in water level may occur with time.
7. Laboratory Testing Results:
WC = Water Content (%)
DD = Dry Density (pet)
105 810
Ge~�t®ch
Hepworth—Paelok Geoteohnlanl
LOGS OF EXPLORATORY PITS
Figure 2
l.
Compression - Expansion %
N 1 p
r i
Moisture Content = 9.0 percent
Dry Density = 120 pcf
Sample of: Sandy Silty Clay
From: Pit 2 at 4.5 Feet
Expansion
upon
wetting
0.t 10 10 100
APPLIED PRESSURE - ksf
105 810
Ggcnech
Hepworth—Partial( Geotechnical
SWELL-CONSOLIDATION TEST RESULTS
Figure 3
COUNTY OF GARFIELD - BUILDING DEPARTMENT
CORRECTION NOTICE
108 8th St., Suite 201 Glenwood Springs, Colorado
Phone (970) 945-8212
Job located at4W( ee 4
Permit No. 52%/
I have this day inspected this structure and these
premises and found the following corrections needed:
. .lam - 6 fez -€y5ec t,,,'
. &7jr—, iJzAee-i ./e .� har t
You are hereby notified that the above correction must be inspected
before covering.
When correction(s) have been made, call for inspection at 970-384-5003.
Date -7 •?`C 6- 20
Building Inspector —77 %zr
Phone (970) 945-8212
No _331 /
Assessor's Parcel Net213 !J- 1°/-°9 ••o
aLLDIND PERMIT CARD
Job Addre�s;�-` • S. d pO
Owner 4 ' t t °E C1hkl.
Contractor 3
Setbacks: Front Rear
eb-t i8
Date ,I! f° C
PtiRa-•-w.re
S ($S 5� ^G. Phone # • 9`-977L
�!$� �rvi t ei .GSPhone #�(t5-r' V
Address
Address
RH
0)/ C6)3' '- INSPECTIONS
Footing C¢—/ -067A -
Soils Test
FoundationjoQ-tdi
Grout N/wr
Underground Plumbing 67-/.5-06,
Rough Plumbing 7 -.2.5" --os" 9,12
Framing 7-_3/-O6
Insulation S - Zr.2
Roofing
Drywall y— hkri
Gas Piping ___Z--ZS--C-13 e/,1
EXTERIOR
Address No.
Drainage
LH
Zoning
Weatherproofing
Mechanical 7
Electrical Rough (State) r
Electrical Final (State) /o-/3-GIS.z A
1 Snail /0-/7-0-6 /Checklist Completed? r✓
Certificate Occupancy #
Date
Septic System # Ss1a
Date
Final
Other ( - 1.3 04 -
NOTES
d&eci - `� Lti
6DIC,0
Decks -support & clearance to wood
Decks -stairs & rails
Exterior locks
Flashing around doors & windywS
Insect screens ✓
INTERIOR
GARAGE
Fire wall separation
Service doors -13/4" min
Door (20 min.) w/auto closer -11' min
Mech. equip 18" above floor
No opening into sleeping area
BASEMENT -CRAWL AREA
Access
Insulation
Headroom/Stairs / \
Ventilation
FINAL CHECKLIST
MECHANICAL ROOM / STAIRWAYS
Headroom (119" )
Railing & guardrails
Width
Rise & run
KITCHEN
Clearance above gni'
Exhaust fan
Broiler exhaust 11 hr chase)
BEDROOMS
Boiler
Hot water
F A. gasrod
Floor drain
Clearance
Air con system
Hol water heater
Combustion air
Gas piping valves
LPG Drain
FIREPLACE/STOVE
Clearance to combustibles
Termination of chimney
Combustion air
Hearth (12" or 20" on sides
Glass doors
Certified by.
REMARKS
(continue on back)
Egress
Smoke detector
BATHROOMS
Exhaust fan
vC,/
Shatterproof glass
OTHER
INSPECTION WILL NOT BE MADE UNLESS
THIS CARD IS POSTED ON THE JOB
24 HOURS NOTICE REQUIRED FOR INSPECTIONS
BUILDING PERMIT
GARFIELD COUNTY, COLORADO
Date Issued ..f .D. Zoned Area Permit No 9 ■ i
AGREEMENT
In consideration of the issuance of this permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location; construction and erection of the proposed
structure for which this permit is granted, and further agrees that if the above said regulations
are not fully complied with in the zoning, location, erection and construction of the above
described structure, the permit may then be revoked by notice from the County Building
Inspector and IMMEDIATELY BECOME NULL AND VOID.
u„51F u ( coo, p&40 +a* Q .� izct$ y'i
resi �
Add Legal• n Ili tt�
Ovine atract �C 4
Seth its Front Side YSide Rear
This Card Must Be Posted So It is Plainly Visible From The Street Uotil Final Inspection.
INSPECTION RECORD
Footing 4v_ / )6
Driveway
Foundation i _i --pc
A/k
Underground Plumbing (c,_,(r--
Insulation F_,a-pG,j
Aa
Rough Plumbing - -- - ,-
Drywall g^ oic_ o6 27)7
Chimney & Vent 7.2.5.-069,A04-
CI
Electric Final &elInspector)/on34 I
Gas Piping 7 -?.6--0674-02
Final /0 _/7....06-l,A,‹
Electric Rough (nyAseinsppIA,06
Septic Final �A
Framing 7-3/-o6Z
(To include Roof in place and Windows
and Doors installed,.
Notes:
ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING -
WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND.
THIS PERMIT IS NOT TRANSFERABLE
For Inspections Call 384-5003 108 8th Street Glenwood Springs. Colorado
APP Q EDDO NOT DESTROY THIS CARD
Date �t °(' By MIkea
IF PLACED OUTSIDE - COVER WITH CLEAR PLASTIC