HomeMy WebLinkAboutApplication-PermitGarfield County
Building & Sanitation Department
108 8th Street, Suite #201 Glenwood Springs, Co. 81601
Office- 945-8212 Inspection Line- 384-5003
Job Address �I,� ggiri w £s1q PL�4c
NO.G16II
Nature of Work Building Permit OLIO -rl`1q-c`a-mq
@ O
Owner ` C4frd o OM -
Contractor IXT cat"46
Use of Building
Amount of Permit $ 2(19 �9
Date gqI VJ
Clerk i.
GARFIELD COUNTY BUILDING PERMIT APPLICATION
108 8r" Street. Brite 201. Glenwood Sprint, CO 81001
I((Phhone: 970-945-8212 / Fu: 870-984-3470 / Inepectlea Line: 970-384-5003
Permit No: t11.J 1
Job Address: 118 Green Mesa Place
2407-074-02-004
Parcel/Schedule No: n 4 0 fN 7 7 R
I Lot No: Block No: Subd / Exe pl1on:
4 2 Willow Creek Village Fi
2
Owner:
Richard L. Witt
Address
68 Hogan Circle
53h:
285-9770
Wk Ph:
3
Contractor:
Witt homes
Address:g
62 Hogan Circle
1F35-7536
We No.
Li4 ncolln1`Devore
4`4ifr:Motor G.J.
Ph`242-8698
W30590
5
Sa. Ft of Building:
366V
Sq. Ft. of Lot:
10289
Height:
23
No of Floors:
2
6
Use of Building:
Residence
7
Describe Work: Composition Roof
Frame new 3BR,3BA, Ranch with walk -out lower level, Hardboard siding
8
Class of Work: CX New ❑ Alteration o Remove
❑ Addition 7 Move
9
Garage: ❑ Single
❑ X Double
Carport: 0 Single
0 Double
10
o Driveway
�" � 7� ❑ Chi -Site Sewage
Yes �s-D-S6 Disposal
a Site Plan
11
Valuation of Work: 8
Adjusted Valuations: S2 CJI, 6 y /fa
`J `� ••fp
12
Special Conditions:
Unfinished //06 S.F. in lower level
A SEPARATE
ISSUED
THIS
AUTHORIZED
CONSTRUCTION
PERIOD
I HEREBY
APPLICATION
PROVISIONS
COMPLETED
GRANfNG
TO
e
OF
NOTICE
ELECTRICAL PERMIT IS REQUmtD AND MUST BIS
BY THE STATE OF COLORADO.
PERMRT BECOMES NULL AND VOID IF WORE OR CONSTRUCTION
1S NOT COMMENCED WITHIN 180 DAYS. OR, IF
OR WORK IS SUSPENDED OR ABANDONED FOR A
OF 180 DAYS AT ANY TIME AFTER WORK 15 COMMENCED.
CERTIFY THAT I HAVE READ AND EXAMINEDTHISI
AND KNOW THIN SAME TO BE TRUE AND CORRECT. ALL
OF LAWS CAVERNING THIS TYPE OF WORK WILL BE
WITHIN WHETHER SPECIFIED HEREIN OR NOT. THE
OF A PERMIT DOES NOT PRESUME TO GIVE AUIHORTTY
VIO - • OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR
REGULATING CONSTRUCTION OR THE PERFORMANCE
eN�'UGIION L i / /�
��4"I / /i/i�.✓1JV/N{�,/A/�f-- `P'�� O ,_Manu.
Plan Check Fee:
I, /73 .7 J
Permit Fee:
/Mos 75
Total Fee:
Dated Per It ssued:
114
I�(I
Const. Type:
Zoning:
Setbacks:
Home:
15J /DS N�o�� &Fee: /'`Q/'
li /' 674,./
IG
F &Z-��.�a,l
'a . -
o
DA
��y,� pt4,�
`
:,,, .
PING. DEPT. �S� ,t��
• 'AL/DATE APPiCVAL/ItAi')< �w
ling 1
AGREEMENT
PERMISSION 15 HEREBY GRANTED TO THE APPLICANT AS OWNER. CONTRACTOR AND/OR THE AGENT OF THE CONTRACTOR OR OWNER TO CONSTRUCT
THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT.
IN CONSIDERATION OF THE ISSSUANCE OF THIS PERMIT THE SIGNER HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND
USE REGUTATONS ADOPTED BY GARFIELD COUNTY PURSUANT TO AUIHORflY GIVEN IN 30.28.201 CRS AS AMENDED THE SIGNER FURTHER AGREES
THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPKED Wmi IN THE LCOATION, ERECTION. CONSTRUCTION. AND USE OF THE
ABOVE DESCRIBED STRUCTURE. THE PERMIT MAY BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT SHALL BECOME
NULL AND VOID. THE ISSUANCE OF A PERMT BASED UPON PLANS SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE BUILDING OFFICIAL
FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING
BUILDING OPERATION BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF THS CODE OR ANY OTHER ORDINANCE OR REGUTATION OF
THIS JURISDICTION. THE REVIEW OF SUBMITTED PIANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONS-TTVIE
AN ACCEPTANCE OF ANY RESPONSIBILITIES OR IIABII LES BY GARFIELD COUNTY FOR ERRORS. OMISSIONS OR DISCRFPENCLES. THE RESPONSI
BLL/TY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICIALLY WITH THE AR 1L I el. L. DE$(GNER BUILDER.
AND OWNER. COMMENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS INTEREST.
Garfom.003
I HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE (I NnUla:
glgc.5c -i{ltloS
oter?Y g
The following items are required by Garfield County for a final inspection:
1. A final Electrical Inspection from the Colorado State Electrical Inspector;
2. Permanent address assigned by Garfield County Building Department posted where readily
visible from access road;
3. A finished roof, a lockable house, complete exterior siding, exterior doors and windows
installed, a complete kitchen with cabinets, a sink with hot & cold running water, non-absorbent
kitchen floor coverings, counter tops and finished walls, ready for stove and refrigerator, all
necessary plumbing;
4. All bathrooms must be complete, with washbowl, tub or shower, toilet stool, hot and cold
running water, non-absorbent floors and walls finished and a privacy door;
5. All steps outside or inside over three (3) steps must have handrails, guard rails on balconies or
decks over 30" high constructed to all IBC and IRC requirements;
6. Outside grading done to where water will detour away from the building;
7. Exceptions to the outside steps, decks and grading may be made upon the demonstration of
extenuating circumstances, i.e. weather, but a Certificate of Occupancy will not be issued until
all the required items are completed and a final inspection made;
8. A final inspection sign off by the Garfield County Road & Bridge Department for driveway
installation, where applicable; as well as any final sign off by the Fire District, anchor State
Agencies where applicable.
A CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL ALL THE
ABOVE ITEMS HAVE BFFN COMPLETED.
****CANNOT OCCUPY OR USE DWELLING UNTIL A CERTIFICATE OF OCCUPANCY
(C.O.) IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE
CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING
PREMISES UNTIL ABOVE CONDITIONS ARE MET.
I understand and agree to abide by the above conditions for occupancyuse and the issuance of a
Certificate of Occupancy for the dwelling under building permit # t36DI
Sig ature
BpcontOct2004
Date
VALUATION/FEE DETERMINATION
Applicant 1l%f]�� Subdivision 0/r-..oaka
Address �fd ta�iW fe�P- a�. Ae�„ Lot/Block
Date gt 2-40 ]S Contractor
Finished (Livable Area):
Main /g ail
Upper
Lower At
Other
Total Square Feet
Valuation
2562 y 74 68 = /91, 3 30 '4
Basement:
Unfinished Wit Zit 3 = 9g2 f 41
Conversion of Unfinished to Finished
Plan Check Fee for Conversion
Valuation
Garage:
Crawl Space:
Valuation 5 78 tC <g
Valuation
Decks/Patios:
Covered
Valuation
Open
Valuation i!o s /2c--
Total
2L
Total Valuation
44242
2 330
244 4310 /(,
Applicant
PLAN REVIEW CHECKLIST
Date 8- Z' 05-
Building
S
Building
✓Engineered Foundation
Driveway Permit
✓Surveyed Site Plan
A Septic Permit and Setbacks
_..-61(ade/Topography 30%
1/4 --'Attach Residential Plan Review List
✓Minimum Application Questionnaire
✓ Subdivision Plat Notes
di. Fire Department Review
W%aluation Determination/Fees
✓Red Line Plans/Stamps/Sticker
t/Attach Conditions
1/4./ Application Signed
V Plan Reviewer To Sign Application
Parcel/Schedule No.
40# Snowload Letter- Manf. Hms.
GENERAL NOTES:
/Planning/Zoning
- v Pseperty Line Setbacks
30 Stream Setbacks
V Flood Plain
t B 'ding Height
v Zo ' g Sign -off
/Road Impact Fees
C. HHOA/DRC Approval
/! Grasle/Topography 40%
PI
ng Issues
Subdivision Plat Notes
GARFIELD COUNTY BUILDING AND PLANNING
970-945-8212
MINIMUM APPLICATION REQUIREMENTS
For
SINGLE FAMILY DWELLING CONSTRUCTION
Including
NEW CONSTRUCTION
ADDITIONS
ALTERATIONS
And
MOVED BUILDINGS
In order to understand the scope of the work intended under a permit application and expedite the
issuance of a permit it is important that complete information be provided. When reviewing a plan
and it's discovered that required information has not been provided by the applicant, this will result
in the delay of the permit issuance and in proceeding with building construction. The owner or
contractor shall be required to provide this information before the plan review can proceed. Other
plans that are in line for review may be given attention before the new information may be reviewed
after it has been provided to the Building Department.
Please review this document to determine if you have enough information to design your
project and provide adequate information to facilitate a plan review. Also, please consider
using a design professional for assistance in your design and a construction professional for
construction of your project. Any project with more than ten (10) occupants requires the plans
to be sealed by a Colorado Registered Design Professional.
To provide for a more understandable plan in order to determine compliance with the building,
plumbing and mechanical codes, applicants are requested to review the following checklist prior to
and during design. Applicants are required to indicate appropriately and to submit the
completed checklist at time of application for a permit.
Plans to be included for a Building Permit, must be on drafting paper at least 18"x24" and
drawn to scale.
1
, Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with
. decks, balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line
and original grade. A section showing in detail, from the bottom of the footing to the top of the roof,
including re -bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation,
sheeting, house -rap, (which is required), siding or any approved building material. Engineered
foundations may be required.
A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be
designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. wind
speed, wind exposure B or C, and a 36 inch frost depth.
All sheets to be identified by number and indexed. All of the above requirements must be met or
your plans will be returned.
All plans submitted must be incompliance with the 2003 IRC.
1. Is a site plan included that identifies the location of the proposed structure or addition and
distances to the property lines from each corner of the proposed structure(s) prepared by a
licensed surveyor and has the surveyors signature and professional stamp on the drawing?
Properties with slopes of 30% or greater must be shown on the site plan. (NOTE
Section: 106.2) Any site plan for the placement of any portion of a structure within 50 ft.
of a property line and not within a previously surveyed building envelope on a
subdivision final plat 'shall be prepared by a licensed surveyor and have the surveyor's
signature and professional stamp on the drawing. Any structure to be built within a
building envelope of a lot shown on a recorded subdivision plat shall include a copy of
the building envelope as it is shown on the final plat with the proposed structure located
within the envelope.
Yes
2. Does the site plan also include any other buildings on the property, setback easements and
utility easements? Please refer to Section 5.05.03 in the Garfield County Zoning Resolution
if the property you are applying for a building permit on is located on a comer lot. Special
setbacks do apply.
Yes
3. Does the site plan include when applicable the location of the I.S.D.S. (Individual Sewage
Disposal System) and the distances to the property lines, wells (on subject property and
adjacent properties), streams or water courses?
Yes
2
.4. Does the site plan indicate the location and direction of the County or private road accessing
the property?
Yes
5. Do the plans include a foundation plan indicating the size, location and spacing of all
reinforcing steel in accordance with the IRC or per stamped engineered design?
Yes
6. Do the plans indicate the location and size of ventilation openings for under floor crawl
spaces and clearances required between wood and earth?
Yes
7. Do the plans indicate the size and location of ventilation openings for the attic, roof joist
spaces and soffjts?
Yes
8. Do the plans include design loads as required by Garfield County for roof snow loads, (a
minimum of 40 pounds per square foot up to & including 7,000 feet above sea level), floor
loads and wind loads?
Yes ✓
9. Does the plan include a building section drawing indicating foundation, wall, floor, and roof
construction?
Yes
10. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling
joists, roof rafters or joists or trusses?
Yes c✓
11. Does the building section drawing or other detail include the method of positive connection of
all columns and beams?
Yes ✓
12. Does the elevation plan indicate the height of the building or proposed addition from the
undisturbed grade to the midpoint between the ridge and eave ofa gable or shed roof or S
top ofa fiat roof? (Building height measurement usually not to exceed 25 feet)
Yes
13. Does the plan include any stove or zero clearance fireplace planned for installation including
make and mode Colorado Phase II certifications or phase II EPA certification?
Yes ✓ No
3
• 14. • Does the plan include a masonry fireplace including a fireplace section indicating design to
comply with the IRC?
Yes No f/
15. Does the plan include a window schedule or other verification that egress/rescue windows
from sleeping oms and/or basements comply with the requirements of the IRC?
Yes No
16. Does the plan include a window schedule or other verification that windows provide natural
light and ventilate for all habitable rooms?
Yes No
17. Do the plans indicate the location of glazing subject to human impact such as glass doors,
glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as
a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures
and specify saff glazing for these areas?
Yes ✓ No
18. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters
indicated on the an?
Yes No
19. Do you understand that if you are building on a parcel of land created by the exemption
process or the subdivision process, are building plans in compliance with all plat notes and/or
covenants?
Yes ✓ No
20. Do you understand that if you belong to a homeowners association, it is your responsibility
to obtain written permission from the association, if required by that association, prior to
submitting an application for a building permit? The building permit application will not
be acceptedwithout it.
Yes / No
21. Will this be the 9aly residential structure on the parcel?
Yes ✓ No If no -Explain:
22. Have two (2) cgmplete sets of construction drawings been submitted with the application?
Yes
23. Do you understand that the minimum dimension a home can be on a lot is 20ft.wide and 20ft.
long? /
Yes t/ No
4
24. Have you designed or had this plan designed while considering building and other
construction cgde requirements?
Yes No
25. Do your plans comply with all zoning rules and regulations in the County related to your
properties zone distri ?
Yes No
26. Does the plan accurately indicate what you intend to construct and what will receive a final
inspection by the Garfield County Building Department?
Yes No
27. Do you understand that approval for design and/or construction changes are required prior to
the application these changes?
Yes No
28. Do you understand that the Building Department will collect a "Plan Review" fee from you
at the time of application submittal and that you will be required to pay the "Permit Fee" as
well as any "Road Impact" or "Septic System" fees required, at the time you pick up your
building permit?
Yes ✓ No
29. Are you aware that you must call in for an inspection by 3:30 the business day before
the requested inspection in order to receive it the following business day? Inspections
will be made from 7:30 a.m. to 3:30 p.m. Monday through Friday. Inspections are to be
called in to 3$4-5003.
Yes t/ No
30. Are you aware that requesting inspections on work that is not ready or not accessible will
result in a Srre-inspection fee?
Yes / No
31. Are you aware that you are required to call for all inspections required under the IRC
including approval on a final inspection prior to receiving a Certificate of Occupancy and
occupancy ofthe building?
Yes �/ No
32. Are you aware that the Permit Application must be signed by the Owner or a written
authority being given for an Agent and that the party responsible for the project must comply
with the IRC?
Yes ✓ No
5
33. Are you aware that prior to submittal of a building permit application you are required to
show proof of a driveway access permit or obtain a statement from the Garfield County Road
& Bridge Department stating one is not necessary? You can contact the Road & Bridge
Department at 62 601.
Yes No
34. Do you understand that you will be required to hire a State of Colorado Licensed Electrician
and Plumber to perform installations and hookups, unless you as the homeowner are
performing the work? The license number of the person performing the work will be
required at time of applicable inspection.
Yes t/ No
35. Are you aware, that on the front of the Building Permit Application you will need to fill in
the ParceUSchedule Number for the lot you are applying for this permit on prior to submittal
of a building permit application? Your attention in this is appreciated.
Yes ✓ No
36. Do you know that the local fire district may require you to submit plans for their review of
fire safety issues? Yes t / No (please check with the
building department about this requirement)
37. Do you understand that if you are planning on doing any excavating or grading to the
property prior to issuance of a building permit that you will be required to obtain a grading
permit? l/
Yes
I hereby acknowledge that I have read, understand and answered these questions to the
st of ability.
Si ture of 1 ner
(
Lr
Date
Phone: c 8 S- 9 7 7 0 (days); - 9 7 7 0 (evenings)
Project Name: Tr -t Mom m R o F_ at_
Project Address: 1 1 if G R EFL) S 4 'pc A C
Notes: If you have answered "No" on any of the questions, you may be required to provide this
information at the request of the Building Official prior to beginning the plan review process. Delays
in issuing the permit are to be expected. Work may not proceed without the issuance of a permit. If
it is determined by the Building Official that additional information is necessary to review the
application and plans to determine minimum compliance with the adopted codes, the application
6
• may be placed behind more recent applications for building permits in the review process and not
reviewed until required information has been provided and the application rotates again to first
position for review, delay in issuance of the permit or delay in proceeding with construction.
BpminregFeb2005
Jun 29 05 03:02p Battlement Mesa Metro Dis 9702859631
BATTLEMENT MESA METROPOLITAN DISTRICT
.109 TAMARISK TRAIL / P.O. BOX 6116 / BATTLEMENT MESA, CO 81636
(970) 285-9050 / FAX (970) 285-9631
EQR Tap Fee Calculation
Da e: February 22, 2005
Buyer: Richard & Gladys Witt
Buyer's Address: PO Box 628
Parachute CO 81635
Service Address: 118 Green Mesa Place
Parachute CO 81635
Subdivision: Willow Creeklow Cre
e
EQR Calculation By: (il'/YN L oP
Amie L Arneson, Utility Clerk
Water Tap Fee = $3,000.00 x 1.0 EQR
Sewer Tap Fee = $2,000.00 x 1.0 EQR
Total Fees Due and Payable Upon Closing
Application Approved By:
Please remit payment to:
• $2200.00
_ $1100.00
• $ 0.00
P. 1
Battlement Mesa Metropolitan District
PO Box 6116
Battlement Mea, CO 81636
We also need a copy of the deed for this property after the closing.
A Water and Sewer Connect Permit is required to connect to the District mains. A
Connect Permit will be issued upon receipt in full of all fees required by the Battlement
Mesa Metropolitan District.
aILOILVOJ OC/.OLJOOL.
1 �
.111.441.' H VU' LUN ll UYL
Garfield County
rmuc uo
AooIw. for Drivewen Permit
Anson Obdobdwj Permit Rekord L 1PJII Perna Number: GI MS -D -$f
Annik rlar Da*: 7/14_5 T...1 dine Dare: 1/1/2MS
Cooney ReaZftL jr 371F &s Mfaee DiM*t:SR lwgrde' Jake Mall
hereby fequests permission and authority from the Bond of Comp Camminiooas to construct a driveway approach (es)
on the right-of-way of ofCounty Rordarlr Gum lap Pin WA WA of At address d 111 Geeta Mea gleet,
located on the rad side of rued for the purpose ofoltretag amen to property.
Applicant wbmt hmewSh for the owvodmetioa ed approval of die Bard ofCounty Commissiooas, a sketch of the
proposed iorallstion showing all the aaammy apeedatioa droll Shadier
1. Frontage of lot ahrg road
2. Dlstascs Brom oaalrl .e armed to paperp lies.
3. Nssnbarofdriveways requested
4. Width of proposed driveways end angle dsppomb.
5. Disgrace from driveway to and iatatmtlion. WO*
6. Sim aad skips dams serrating driveways if more than aro approach.
7. Seebeck distance of bat'ldig(s) and ale swan tarpron a
1. No unlashes of aquipmat o0 opine and. cry deeep awed to wanly mad will be repelled at subdivision
9. Riopelle for two years tom the lard am lmioa.
thadttura
1) Tbs applicsm mpressett all pegs is ideal; and JILs dim me driveway approach (es) is to he constructed by
him for de bona fide purpose of aim noes es his propety ad not for the purpose of doing business a
servicing vehicles a the road right of way.
2) The appliaast sh.b Ravish d labor ed s.arri.lr, psaform all work, ed pay all cats in connection with the
ooaset0etioa aft domway(s). Al work doll be eospieled within thirty (30) days of the permit date.
3) The type do merae:don skid be as &dpdsd ntd/or egp0nd byte Band of CAe4' Coaeeo6siceen or thea
to tenure sod all avtaerials rued rise be detidtorry sway and subject to inspection sod approval tithe
Boots of Comity Commissioners or duderepwwtative.
4) The trawling g public shall be protected daring dr iaaallmaa wig proper vanes rips sed Spell ad the Bond
ofCounty Caaoeisiooes and their duly appointed spme ed employee shall be hold bales against my action
for perml any or property damp am/ pa ray sermon of the swim of the Permit
5) The Apples shall sus respom"Mlip for the sa.slsl or clauams of avow, icer or rlem upon sed portion of
the drivev,'ay appoaob (es) nun though deposited an the driveway(s) In the coarse of the Corte mow removal
1
COPY
BATTLEMENT MESA SERVICE ASSOCIATION
ARCHITECTURAL COMMITTEE APPLICATION & CHECKLIST
(for New Home Construction projects)
Homeowner. Richard L. Witt
Home Mailing Address: 1' 0 nox 628 PatachuLe , C0 $1635
Home Phone: 285-9 / /0 Work Phone (if desired):
Project Address: 118 Green Mesa Place Lot: 4
Production Homeplan Name (if applicable): t,us t oat —
Block:
2 Subdivision:Willow Creek Village
Homebuilder. Richard L. Witt and Roan Cliff Corporation dba Witt 'Tomes
Business Mailing Address: P 0 Box 628
Business Phone: 285-9770 Fax (if desired): 21:15-159b
Submittal Date: 06/30/05 Estimated Start Date: 08/01/05 Estimated Completion Date: 03/01/06
SUBMITTAL REQUIREMENTS: Two copies each of items 1, 2 & 4 need to be submitted.
(Check -off items attached to the Application. Fill in spaces as indicated.)
x 1. Site Plan Drawing (r=10' or I"=20' scale) with the following information shown:
x Lot, Block & Subdivision name.
Street Address of Project.
x Building Setback Lines (also fill-in the shortest distance between property line to the exterior wall
closest to that property line). Please be aware that all Brindisi Setback Lines are taken from your
Property Line Pins !! Your Property Line is not the Curb Line !!
Dwelling Unit G
Front Setback: 'rre tfeet 26 feet
Left Side Setback: —11— feet feet
Right Side Setback: /.i feet i feet
Rear Setback: 30 feet fat
Utility Easemeab.
55' Clear Site -Line at Intersection Corner Lots.
Site Grading Elevations & Drainage.
First (main) Floor Height in relation to top of street curb at front -center of lot.
Driveways (include width of driveway), Walkways, Patios, etc.
Outbuildings
a:lbmsaac.ap2.draft031698 Page 2 of 5
2. Architectural Drawings (114" = 1' or 1/8" = 1' scale) with following information shown.
Floor Plan(s) with overall dimensions (fill-in the following square foot areas).
First Floor Finished Living Area:
Second Floor Finished Living Area:
Lower Floor Finished Living Area:
Total Finished Living Area
Total Unfinished Living Area:
Garage Area
1834 square feet
square feet
728 square feet
2563 square feet
square fat
5 9 8 square feet
x Building Elevations Plans indicating doors, windows, exterior materials, building height, roof pitch,
roof -mounted evaporative coolers, etc. (fill-in maximum height below).
Maximum building height to highest ridgeline or building structural projection .vie feet above
top of strew curb elevation at front -center of your lot
x Engineered Foundation Plan.
n / a Outbuildings indicating dimensions, elevations and overall height to ridgeline.
x 3. Exterior Materials (fill-in the selections below):
Architectural Style
x Roofing Material: Compost tion Shingletoj TBD
x Primary Siding Material: HardboardTBD
Cofar
x Accent Siding Material: Cedar Color fall
x Trim Material: Cedar Color: TBD
Masonry Material: Cul tured Stone Colon TBD
Color.
Stucco Material:
x Front Door Material: Fiberglass insula Mar: TDB
x Garage Door Material: Steel , insulatedcolor TBD
COLOR SAMPLE
COLOR SAMPLE
a1bmsaac.ap2.draft031698
COLOR SAMPLE
COLOR SAMPLE
Page 3 of 5
COLOR SAMPLE
COLOR SAMPLE
4: Landscape/lrrigation Plans with the following information:
Planting Plan (indicate areas of irrigated lawn, tree placement, shrub beds, groundcover, etc.).
Plant Material Listing by species of trees and shrubs.
Groundcover Material with weed control barrier.
Fences.
Other Landscape Improvements (decks, site lighting, flag poles, etc.).
5. Application Fee (payable to Battlement Mesa Service Association Architectural Committee):
, The BMSA/AC may require the applicant to pay directly, or to reimburse the BMSA/AC for payment of,
any fees of outside consultants or any costs insured by the BMSA/AC in its research review or
consideration of this application (per Section 9.6, Amended and Restated Declaration).
UWe hereby acknowledge and understand that our failure to complete Homeplan or
Improvement Projects or Landscaping Construction within the time constraints noted in
Conditions 2. & 3. on Page 5 of this Application will result in a Notice and opportunity for a
Hearing before the BMSA Board of Directors, and if We are found in violation of these
Conditions at the Hearing will result in a fine to the Owner of not less than 5500.00 per month
for each full month in excess of the allotted completion time frame.
I/We hereby acknowledge that Homeplan or Improvement Projects or Landscape Construction
features which are built in non-conformance with this full application, including the Conditions
of Approval noted on Page 5 of 5 herein, l/We will be cited by the BMSA/AC in written citation
form at the time of discovery. In extenuating circumstances a Variance may be requested from
the BMSA/AC, provided such Variance request item is within the purview and approval
jurisdiction of the BMSA/AC. U a Variance is not granted by the BMSA/AC and if the Non -
Conforming Items are not corrected within 60 days after the date of written citation, I/We will
be served Notice and opportunity for a Hearing before the BMSA Board of Directors, and if I/We
are found in violation of these Non -Conforming Items at the Hearing will be fined a minimum -
of 5500 per Non -Conforming item.
Failure to pay fines levied as determined at the Hearings may also result in a Lien being placed
on our Property or Litigation Process initiated by the BMSA Board of Directors to secure
conformance with this full Application and its respective Conditions Of Approval.
I/We further acknowledge that any subsequent field changes which I/We may desire to the
Homeplan or Improvement Projects of this original Application Submittal and the original
Condition of Approval issued by the BMSA/AC will require an additional Revised Application
Submittal on our behalf, and that 1/We will not proceed with any subsequent field changes until
a Revised Conditions of Approval have been issued to us by the BMSA/AC.
Owner's Signature(s):/ - r%' Print Name(s): Richard L. Witt Date: A?
Builder's Signature:
a%7 ntName: Richard L. Witt
a:\bmsaac.ap2.draft031698
Page 4 of 5
Date:
Date: ea -D4:.---
. This portion of the Application Form to be completed by the
Architectural Committee (not the Applicant).
CONDITIONS OF APPROVAL
No sitework or building construction may proceed on any Lot (including no preliminary site clearing, grubbing,
grade alteration, storing of material, foundation excavation, extension of underground utilities, etc.) until the Project
has received a Project Approval from the Architectural Committee and has been issued a Building Permit (as
required by Garfield County for New Home or Renovation projects).
2. All general building and site improvements constructio,n for any Project shall be completed and shall have issued
a Catifcatie of Occupancy from the Garfield County Building Dept no later than one (1) rear after the issuance
date of this Architectural Committee Approval.
3. The completed landscaping and revegetation of the improved Lot, to specifically include the front, side and rear
yard areas, shall be completed no later than six (6) months from the date of Certificate of Occupancy. An
additional maximum four (4) month extension may be granted by the Architectural Committee if the Catificate
of Occupancy was issued shortly prior to the non -growing winter months such that landscape construction could
not diligently proceed; however, in any event, the landscsping construction shall be fully complete no later than
ten (10) months from the date of Certificate of Occupancy.
4.
5.
6.
7.
8.
9.
Appliationval (Initials ofAt�hitectural om Membps
By: fC. lfJ
Application Approv for Const tion subject to the ve conditions:
By Chairman: Date: 7 -4-or
Application Denied (Initials of Architectural Committee Members):
By:
Application Denied:
By Chairman:
sAbmsaac.ap2.dratt031698 Page 5 of 5
Date:
0
0
0
0
0
1
0`13
O
0cu7
0
0
3
0.
0
0
0
-c
0
0
T
0
V
O
W
A
O
0
0
7•
W
Q
O
a
Cr CUz
O S
m
CD
0 m
o 0
o
m fpfp
7 0
3 n
0 O
0
0
7
3
N
0-
5 s
0
0
0
0.
yam,
N•
A
M
co S
0 N
0.
y,
O d
C1/44
o.
S
tD m
o QfD
—
f ?
y
5.
CO cn
C
O 0.
co C
o
w N
0 C.
co M
N 0
N N
Q 0
m
0.
co
%D —♦ ip
7• 1'. 0
0
tr7
ol
cn Qt%. - at
t
0.
s
al
0o;
a:
d
O cr
ce
i
m <
m
Li. n
IC O
it
0
3 p __it,3
acif
5
0
00
5
0
0.
'0 —
3 0)
0
co ?
Q N
Q
o•
Q
CD n
o
'N
co M
fl.1
o�
CD
co) 0.
co 0D
Q N
0.
'ON 31wJad
3
Z
O
;e pa;e3ol qof
;e pa;enol qor
"is 438 801
0
tic
Z
i
C XI O
roM D
N�
c-
mO n m
O TI
3 �m
'� r
-0
to
O.
W
C
VI 3 r
N O
N O. Z Z
c
-o v
Am
co
H D
�
al
ti
a
o p
co C
N
c M 9
N r11 D
_�
• �TI
m
iiie
—v
CDmo W
co 0
v_
N ° Z ^/
YZ
co
v
2. �
M
y ak D
n 73
O rn3
o m
0) Z
o.
O —i
Assessor's Parcel No
Date f
k (� BUILDING PER nRD LLjr u �/�
Job Address 1 ZS �l 912. tp Aa .P, l i /► /01 ci Si
AddressiA l u Phone #QST 97 7O
r hi-��"
Contractor � Phone #n
Owner UNI -11 T -\l
Address
Sk Front Rear RH LH Zoning
INSPECTIONS
Soils Test
kit MQ
Footing /7-,-75-0.S /0724.—
Foundation
87lCFoundation /2 -1-5-45-049M.
Grout .,.�77��
Underground Plumbin,,QQ ►2^2? -D -C/0/4
Rough Plumbing ;C-26'4* ern.
Framing 3-4-06/er A.
Insulation -4-‘2 c4 /ark -
Roofing
Drywall
Gas Piping a2 -2$-064n'.- Other
NOTES
3-1(0 -06 awl
Weatherproofing
Mechanical /
Electrical Rough (State) 2-/e) .8»
Electri Final (State) 2 D6 .EF
Fina 6 /Checklist Completed? -"
Certificate Occupancy # J 33 I
Date S/9/06
Septic System #
Date
Final
(continue on back)
- INSPECTION WILL NOT BE MADE UNLESS
THIS CARD IS POSTED ON THE JOB
24 HOURS NOTICE REQUIRED FOR INSPECTIONS
BUILDING PERMIT
GAppRFIELD COUNTY, COLORADO
Date Issued.$1.140'Zoned Area Permit Not./1
AGREEMENT
In consideration of the issuance of this permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location; construction and erection of the proposed
structure for which this permit is granted, and further agrees that if the above said regulations
are not fully complied with in the zoning, location, erection and construction of the above
described structure, the permit may then be revoked by notice from the County Building
Inspector and IMMEDIATELY BECOME NULL AND VOID.
Use
Add r Legal Deseripti n
Owaer
Contracto
Setbacks Front Side Side Rear
This Card Must Be Posted So It is Plainly Visible From The Street Until Final Inspection.
INSPECTION RECORD
Footing l i - 23-5 kyit
Driveway p , _ ,6, y j. 47.
Foundation f 2-15-p5 /cm
6754/go
Underground Plumbing /,. .a,-/_ps a vt,
Insulation 34-6/69(cy%¢J
Rough Plumbing a-fl-Dent...
Drywall 3 -/" ..o
Chimney & Vent z -2&pb MK.
Electric Final (by b dr
e
Gas Piping 2.•2 -K -o6 ,Q7yt,
Final s. y_06 ,GLivt
Electric Roug eta ector) 2/4a
Septic Final 4A.
Framing g,(,_ p k
fro include Boot in place a Windows
and Doors installed).
Notes:
ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING -
WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND.