HomeMy WebLinkAboutPlumbing Specs.pdfChapter 29 - Plumbing Systems Page 1 of 5 CCluckherefor ,I PAID Subscriptions J • International Building Code o J 2012 (Second Printing) 1 • Chapter 29 - Plumbing Systems • SECTION 2901 GENERAL • SECTION 2902 MINIMUM PLUMBING FACILITIES [P1 2902.1 Minimum number of fixtures. ]P] 2902.2 Separate facilities. JP1 2902.3 Employee and public toilet facilities. JP] 2902.4 Signage. JP1 2902.5 Drinking fountain location. JP] 2902.1 Minimum number of fixtures. JP] 2902.2 Separate facilities. JP] 2902.3 Employee and public toilet facilities. JP1 2902.4 Signage. JP] 2902.5 Drinking fountain location. Top Previous Section Next Section To view the next subsection please select the Next Section option. SECTION 2902 MINIMUM PLUMBING FACILITIES [P] 2902.1 Minimum number of fixtures. Plumbing fixtures shall be provided for the type of occupancy and in the minimum number shown in Table 2902.1. Types of occupancies not shown in Table 2902.1 shall be considered individually by the building official. The number of occupants shall be determined by this code. Occupancy classification shall be determined in accordance with Chapter 3. [P] TABLE 2902.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES' (See Sections 2902.2 and 2902.3) No. CLASSIFICATION OCCUPANCY DESCRIPTION WATER CLOSETS (URINALS SEE SECTION 419.2 OF THE INTERNATIONAL PLUMBING CODE) LAVATORIES BATHTUBS/ SHOWERS DRINKING FOUNTAINse'f (SEE SECTION 410.1 OF THE INTERNATIONAL PLUMBING CODE) OTHER MALE FEMALE MALE FEMALE 1 Assembly (continued) A-ld Theaters and other buildings for the performing arts and motion pictures 1 per 125 1 per 65 1 per 200 — 1 per 500 1 service sink A-2 d Nightclubs, bars, taverns, dance1 halls and buildings for similar purposes 140 r 1r 1 per 40 1 per 75 — 1 per 500 service sink Restaurants, banquet halls and food courts 1 per 11 per 75 1 per 200 — 1 per 500 1 service sink A -3d Auditoriums without permanent seating, art galleries, exhibition halls, museums, lecture halls, libraries, arcades and gymnasiums 1 per 125 1 per 65 1 per 200 — 1 per 500 1 service sink Passenger terminals and transportation facilities 1 per1 500 per 500 1 per 750 — 1 per 1,000 1 service sink Places of worship and other religious services 1 per 150 1 per 75 1 per 200 — I per 1,000 1 service sink http://publicecodes.cyberregs.com/icod/ibc/2012/icod ibc_2012 29_sec002.htm 9/11/2014 Chapter 29 - Plumbing Systems (continued) [P] TABLE 2902.1—continued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES' Page 2 of 5 No. CLASSIFICATION OCCUPANCY DESCRIPTION WATER CLOSETS (URINALS SEE SECTION 419.2 OF THE INTERNATIONAL PLUMBING CODE) LAVATORIES BATHTUBS/ SHOWERS DRINKING FOUNTAINSe,f (SEE SECTION 410.1 OF THE INTERNATIONAL PLUMBING CODE) OTHER MALE FEMALE MALE FEMALE 1 Assembly A-4 Coliseums, arenas, skating rinks, pools and tennis courts for indoor sporting events and activities 1 per 75 for the first 1,500 and 1 per 120 for the remainder exceeding 1,500 1er 40 for the first 1,520 and 1 per 60 for the remainder exceeding 1,520 1 per 200 1 per 150 — 1 per 1,000 1 service sink A-5 Stadiums, amusement parks, bleachers and grandstands for outdoor sporting events and activities 1 per 75 for the first 1,500 and 1 per 120 for the remainder exceeding 1,500 1 per 40 for the first 1,520 and 1 per 60 for the remainder exceeding 1,520 1 per 200 1 per 150 — 1 per 1,000 1 service sink 2 Business B Buildings for the transaction of business, professional services, other services involving merchandise, office buildings, banks, light industrial and similar uses 1 per 25 for the first 50 and I per 50 for the remainder exceeding 50 1 per 40 for the first 80 and 1 per 80 for the remainder exceeding 80 — 1 per 100 1 service sink g 3 Educational E Educational facilities 1 per 50 1 per 50 — 1 per 100 1 service sink 4 Factory and industrial F-1 and F-2 Structures in which occupants are engaged in work fabricating, assembly or processing of products or materials 1 per 100 1 per 100 See Section 411 of the International Plumbing Code 1 per 400 1 service sink 5 Institutional I-1 Residential care l per 10 1 per 10 1 per 8 1 per 100 1 service sink 1-2 Hospitals, ambulatory nursing home care recipientb 1 per per room° 1 per per room 1 per 15 1 per 100 1 service sink Employees, other than residential careb 1 per 25 1 per 35 — 1 per 100 — Visitors, other than residential care 1 per 75 1 per 100 — 1 per 500 — I-3 Prisonsb 1 per cell 1 per cell 1 per 15 1 per 100 1 service sink Reformatories, http://publicecodes.cyberregs.com/icod/ibc/2012/icod_ibc 2012_29_sec002.htm 9/11/2014 i Chapter 29 - Plumbing Systems detention centers and correctional I-3 centersb I-4 1perl5 1perl5 1 per 15 1 per 100 Page 3 of 5 1 service sink Employeesb Adult day care and child day care 1 per 25 1 per 35 1 per 15 lper 15 1 1 per 100 1 per 100 (continued) [P] TABLE 2902.1—continued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES' (See Sections 2902.2 and 2902.3) 1 service sink No. CLASSIFICATION OCCUPANCY DESCRIPTION WATER CLOSETS (URINALS SEE SECTION 419.2 OF THE INTERNATIONAL PLUMBING CODE) LAVATORIES BATHTUBS OR SHOWERS DRINKING FOUNTAINSe,f (SEE SECTION 410.1 OF THE INTERNATIONAL PLUMBING CODE) OTHER MALE FEMALE MALE FEMALE 6 Mercantile M Retail stores, service stations, shops, salesrooms, markets and shopping centers 1 per 500 1 per 750 — 1 per 1,000 1 service sig 7 Residential R-1 Hotels, motels, boarding houses (transient) 1 per sleeping unit 1 per sleeping unit 1 per_ sleeping unit 1 service sink R-2 Dormitories, fraternities, sororities and boarding houses (not transient) 1 per 10 1 per 10 I per 8 1 per 100 1 service sink R-2 Apartment house 1 per dwelling unit 1 per dwelling unit 1 per dwelling unit — 1 kitchen sink per dwelling unit; 1 automatic clothes washer connection per 20 dwelling units R-3 One- and two family dwellings 1 per dwelling unit 1 per 10 1 per dwelling unit _ 1 kitchen sink per dwelling unit; 1 automatic clothes washer connection per dwelling unit R-3 Congregate living facilities � 16 or fewer wipersons 1 per 10 1 per 10 1 per 8 1 per 100 1 service sink R-4 Congregate living facilities 16 or fewer withpersons 1 per 10 1 per 10 1 per 8 1 per 100 1 service sink 8 Storage S-1 S-2 Structures for the storage of goods, warehouses, storehouses and 1 per 100 1 per 100 See Section 411 of the International 1 per 1,000 1 service http://publicecodes.cyberregs.com/icod/ibc/2012/icod_ibc_2012 29_sec002.htm 9/11/2014 Chapter 29 - Plumbing Systems Page 4 of 5 freight depots, low and moderate hazard Plumbing Code sink a. The fixtures shown are based on one fixture being the minimum required for the number of persons indicated or any fraction of the number of persons indicated. The number of occupants shall be determined by this code. b. Toilet facilities for employees shall be separate from facilities for inmates or care recipients. c. A single -occupant toilet room with one water closet and one lavatory serving not more than two adjacent patient sleeping units shall be permitted where such room is provided with direct access from each patient sleeping unit and with provisions for privacy. d. The occupant load for seasonal outdoor seating and entertainment areas shall be included when determining the minimum number of facilities required. e. The minimum number of required drinking fountains shall comply with Table 2902.1 and Chapter 11. f. Drinking fountains are not required for an occupant load of 15 or fewer. g. For business and mercantile occupancies with an occupant load of 15 or fewer, service sinks shall not be required. [P] 2902.1.1 Fixture calculations. To determine the occupant load of each sex, the total occupant load shall be divided in half. To determine the required number of fixtures, the fixture ratio or ratios for each fixture type shall be applied to the occupant load of each sex in accordance with Table 2902.1. Fractional numbers resulting from applying the fixture ratios of Table 2902.1 shall be rounded up to the next whole number. For calculations involving multiple occupancies, such fractional numbers for each occupancy shall first be summed and then rounded up to the next whole number. Exception: The total occupant load shall not be required to be divided in half where approved statistical data indicate a distribution of the sexes of other than 50 percent of each sex. [P] 2902.1.2 Family or assisted -use toilet and bath fixtures. Fixtures located within family or assisted -use toilet and bathing rooms required by Section 1109.2.1 are permitted to be included in the number of required fixtures for either the male or female occupants in assembly and mercantile occupancies. [P] 2902.2 Separate facilities. Where plumbing fixtures are required, separate facilities shall be provided for each sex. Exceptions: 1. Separate facilities shall not be required for dwelling units and sleeping units. 2. Separate facilities shall not be required in structures or tenant spaces with a total occupant load, including both employees and customers, of 15 or less. 3. Separate facilities shall not be required in mercantile occupancies in which the maximum occupant load is 100 or less. [P] 2902.2.1 Family or assisted -use toilet facilities serving as separate facilities. Where a building or tenant space requires a separate toilet facility for each sex and each toilet facility is required to have only one water closet, two family/assisted-use toilet facilities shall be permitted to serve as the required separate facilities. Family or assisted -use toilet facilities shall not be required to be identified for exclusive use by either sex as required by Section 2902.4. [P] 2902.3 Employee and public toilet facilities. Customers, patrons and visitors shall be provided with public toilet facilities in structures and tenant spaces intended for public utilization. The number of plumbing fixtures located within the required toilet facilities shall be provided in accordance with Section 2902.1 for all users. Employees shall be provided with toilet facilities in all occupancies. Employee toilet facilities shall either be separate or combined employee and public toilet facilities. Exception: Public toilet facilities shall not be required in open or enclosed parking garages. Toilet facilities shall not be required in parking garages where there are no parking attendants. [P] 2902.3.1 Access. The route to the public toilet facilities required by Section 2902.3 shall not pass through kitchens, storage rooms or closets. Access to the required facilities shall be from within the building or from the exterior of the building. All routes shall comply with the accessibility requirements of this code. The public shall have access to the required toilet facilities at all times that the building is occupied. [P] 2902.3.2 Location of toilet facilities in occupancies other than malls. In occupancies other than covered and open mall buildings, the required public and employee toilet facilities shall be located not more than one story above or below the space required to be provided with toilet facilities, and the path of travel to such facilities shall not exceed a distance of 500 feet (152 m). Exception: The location and maximum travel distances to required employee facilities in factory and industrial occupancies are permitted to exceed that required by this section, provided that the location and maximum travel distance are approved. [P] 2902.3.3 Location of toilet facilities in malls. In covered and open mall buildings, the required public and employee toilet facilities shall be located not more than one story above or below the space required to be provided with toilet facilities, and the path of travel to such facilities shall not exceed a distance of 300 feet (91 440 mm). In mall buildings, the required facilities shall be based on total square footage (m2) within a covered mall building or within the perimeter line of an open mall building, and facilities shall be installed in each individual store or in a central toilet area located in accordance with this section. The http://publicecodes.cyberregs.com/icod/ibc/2012/icod ibc 2012 29 sec002.htm 9/11/2014 Chapter 29 - Plumbing Systems Page 5 of 5 maximum travel distance to central toilet facilities in mall buildings shall be measured from the main entrance of any store or tenant space. In mall buildings, where employees' toilet facilities are not provided in the individual store, the maximum travel distance shall be measured from the employees' work area of the store or tenant space. [P] 2902.3.4 Pay facilities. Where pay facilities are installed, such facilities shall be in excess of the required minimum facilities. Required facilities shall be free of charge. [P] 2902.3.5 Door locking. Where a toilet room is provided for the use of multiple occupants, the egress door for the room shall not be lockable from the inside of the room. This section does not apply to family or assisted -use toilet rooms. [P] 2902.4 Signage. Required public facilities shall be designated by a legible sign for each sex. Signs shall be readily visible and located near the entrance to each toilet facility. Signs for accessible toilet facilities shall comply with Section 1110. [P] 2902.4.1 Directional signage. Directional signage indicating the route to the public facilities shall be posted in accordance with Section 3107. Such signage shall be located in a corridor or aisle, at the entrance to the facilities for customers and visitors. [P] 2902.5 Drinking fountain location. Drinking fountains shall not be required to be located in individual tenant spaces provided that public drinking fountains are located within a travel distance of 500 feet of the most remote location in the tenant space and not more than one story above or below the tenant space. Where the tenant space is in a covered or open mall, such distance shall not exceed 300 feet. Drinking fountains shall be located on an accessible route. Top Previous Section Next Section To view the next subsection please select the Next Section option. COPYRIGHT 2007 by INTERNATIONAL CODE COUNCIL http://publicecodes.cyberregs.com/icod/ibc/2012/icod ibc 2012 29 sec002.htm 9/11/2014 Oa. ARCHITECT STRUCTURAL LANDSCAPE NOTES ISSUES PC G[333.973.9 139,9 Tenant Finish Pion 82 Liquor colied County aem.o.J, Co Tenant Finish Floor Plan 14193 **mbar 10, 0014 A 1.1