Loading...
HomeMy WebLinkAbout6.0 Amendment of Existing Site Location ApprovalSCHMUESER GORDON I MEYER ENGINEERS SURVEYORS Monday, August 08, 2005 GLENWOOD SPRINGS ASPEN CRESTED BUTTE 1 18 W. 6TH, SUITE 200 P.O. BOX 2 155 P.O. BOX 3088 GLENWOOD SPRINGS, CO 81 601 ASPEN, CO 81 61 2 CRESTED BUTTE, CO 81 224 970-945-1004 970-925-6727 970-349-5355 FX: 970-945-5948 FX: 970-925-4157 Fx: 970.349-5358 Mark Bean (Via Mail and Email mbean@garfield-county.com) Garfield County Planning Department 108 8th Street Suite 201 Glenwood Springs CO 81601 RE: West Glenwood Sanitation District — Site Application Extension Dear Mark, Enclosed with this letter is an application for amendment of an existing site location approval, for the West Glenwood Sanitation District WWTF Expansion. As required under CDPHE Regulation 22, you have fifteen days (15) days to direct any comments to: Mark Kadnuck Colorado Department of Public Health and Environment, WQCD 4300 Cherry Creek Dr South Denver, CO 80246-1530 The District intends to begin construction of its WWTF expansion within the next few months. If you have any questions, please contact me at (970)945-1004 or by email at gregs@sgm-inc.com. Thank you for your time and consideration. Best Regar Schmues r ordon Greg Schr. eder, P.E. eyer, Inc. Cc: Mark Kadnuck, CDPHE (via Email, Mark.kadnuck@state.co.us) Enc. Site Application Amendment Form (3 pages) RECEIVED AUG 0 9 2005 CART- itLD COUNTY BUILDING & PLANNING 1:\1996\96103\96103A - Correspond115 - Project Management120050808_MarkBean.doc Page 1 of 1 COLORADO DEPARTMENT OF PUBLIC HEALTH AND ENVIRONMENT Water Quality Control Division 4300 Cherry Creek Drive South Denver, Colorado 80246-1530 (303) 692-3500 APPLICATION FOR AMENDMENT OF AN EXISTING SITE LOCATION APPROVAL (Section 22.8(2)(b)(i)(iii)(iv)(v)(vj),(c),(d), and (e) Regulation #22) Applicant: Phone: Address: City, State, zip: Email Address epc@sopris.net Primary Contact (for project inquiries): Greg Schroeder Phone: 970-945-1004 Consulting Engineer: Schmueser Gordon Meyer, Inc. Phone: 970-945-1004 Address: 118 W. 6th Street, Suite 200 City, State, zip: Glenwood Springs, CO 81601 Email Address gregs@sqm-inc.com 1. Site Approval Number: 4713 Site Approval Date: February 2, 2004 2. Permitted treatment plant capacity: Requested treatment capacity: Hydraulic: 600,000 gal/day Hydraulic: gal/day (maximum monthly average) Organic: 1,252 lbs. BODS/day Organic: lbs. BOD5/day If an increase in rated capacity of the treatment plant is being requested, include an engineering evaluation of the plant's treatment capacity as well as its ability to meet all applicable effluent limitations at the higher rated capacity. 3. Current treatment process: Proposed treatment process modifications: WQCD-3d (Revised 7/04) Page 1 of 3 4. Current type of discharge: Surface discharge to watercourse (list receiving watercourse) Colorado River Subsurface disposal: Land Application: Evaporation: Evapo-transpiration: Other: (List) Proposed type of discharge: Surface discharge to watercourse (list receiving watercourse) Colorado River State water quality classification of proposed receiving watercourse: Subsurface disposal: Land Application: Evaporation: Evapo-transpiration: Other: (List) 5. Current location of discharge (stream segment and legal description): SE1/4NW1/4, Sec. 6 T6S R89W, Colorado River, Region 11, Lower Colorado River Basin, Description #1 Proposed location of discharge (stream segment and legal description): Same as Current 6. Please identify any additional factors that might help the Water Quality Control Division make an informed decision on your amendment request: Amendment request due to Agreement with CDPHE regarding treatment and redundancy issues being addressed in Sept. 2004, and subsequent PDR approval effective in Jan. 2005. Plans and Specifications production started in Jan 2005 and bid in July 2005. B. If the facility will be located on or adjacent to a site that is owned or managed by a federal or state agency, send the agency a copy of this application for the agency's review. WQCD-3d (Revised 7/04) Page 2 of 3 C. Request submitted to the following governmental entities; Please list below those entities to whom copies of this application have been provided as well as the date on which the application was transmitted to each entity. These entities shall be allowed 15 working days from receipt of the request to comment directly to the Water Quality Control Division, If you have any further comments or questions, please call (303)692-3500. Entity Agency Name Date Sent 1. Management Agency: (If different from entities listed below) 2. County: Garfield County 8/5/2005 (If site is outside located in an unincorporated area of the County) 3. city or Town: City of Glenwood Springs 8/5/2005 (If site is located within 3 miles of the bouodarice of a City or Town) 4, Local Health Authority: 5. 208 Management Agency: 6. Other State or Federal Agencies: (If facility would be located adjacent any land owned or managed by state or federal agency) 1 certify that 1 am familiar with the requirements of the "Site Location and Design Approval Regulations for Domestic Wastewater Treatment Works". Date 8/05/2005 547 ature of Applicant* Typed Name and Title r_ Jerry Law, WGSD President *This form must be signed by the applicant. This form cannot be signed by the Consulting Engineer. WQCD-3d (Revised 7/04) Page 3 of 3