HomeMy WebLinkAboutOWTS Installation Observations 12.31.14 December 31, 2014 Project No. C1023 Louisa Morrissey and Benjamin Young louisammorrissey@gmail.com benjaminyoungmd@gmail.com Onsite Wastewater Treatment System (OWTS) Installation Observations Lot 9, Mountain Springs Ranch Garfield County, Colorado Garfield County Permit No. SEPT-5-13-2827 Louisa and Benjamin, ALL SERVICE septic, LLC observed the installation of the onsite wastewater treatment system (OWTS) on November 5, 2014 for the subject property. Walters Company installed the system. The installation included a new 1000-gallon, two-compartment concrete Valley Precast septic tank with a dosing siphon in the second compartment. The screen on the dosing siphon should be cleaned annually, or as needed. The soil treatment area (STA) included four sections of subsurface drip irrigation, each section consisting of six 66’ long laterals for a total of 3168 square feet of infiltrative area. Laterals were installed between 24 and 30-inches in depth. We recommend utilizing 75% of the subsurface drip system (three sections), allowing 25% of the system (one section) to rest. The section that is turned off must be rotated annually. Either a service provider or the homeowner must be responsible for executing, tracking, and documenting the rotation as part of the routine maintenance for this system. The OWTS was generally installed according to specifications. This observation is not a guarantee of workmanship and/or parts and materials. ALL SERVICE septic, LLC should be notified if changes are made to the OW TS in the future. Any additional OWTS construction must be according to the county regulations. LIMITS: Observations are limited to components that are visible at the time of the inspection. The installer must have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. The quality of the installation is dependent of the expertise of the installer, soil type, and weather conditions. Please call with questions. Sincerely, ALL SERVICE septic, LLC Reviewed By: Carla Ostberg, MPH, REHS Richard H. Petz, P.E. 1000-gallon, two-compartment concrete septic tank prior to backfill Screened dosing siphon in second compartment 2-inch subsurface drip line 4-inch sewer line from septic tank to distribution valves Installing laterals Valve box (rotate closed valve annually) 832‐R‐13‐002