Loading...
HomeMy WebLinkAboutFire Sprinkler plans2 3 4 6 = B c 1\ ~ ' . ' . PER N.F.P .A. 13R ..,...-..,...---++-HEAD IN THIS ROOM USED IN ONE HEAD CALC D 1B2'-2' (!} ~llRlOIIS l.fSS ~ 55 9l FT N.A.S. (Y Cl.OSEf l.fSS ~ 24 SQ FT N.A.S. ~ UPPER FLOOR PIPING PLAN ~UY 1/t = 1· E c;:= = NOTE : ALL CEIUNGS TO BE 8' -0" U.N.O. PIPING ON THIS FLOOR TO BE CPVC F , SEE PIPING DErM. 4-1 /-.J. (!) 1 1 (!) 1 / ;;!:~ \ (!) I ,... 1 1 1 1 1NSPECillR lEST 'i' - ~ 1 1H ... .... 11111 Toe 1H --+----=---~~ ®\1) ... b EJal FH PI«JIECikM 1 st!RI AI 4X 9 F1M11: u.w:a RISER DETAIL , .. ,. 1H "' ~ , 1~ llPl:ltl. ROOF ~ MAIN FLOOR PIPING PLAN ~UY 1/t=t· , 1H 14-0 (MECHANICAL ROOM) ~ CRAWL SPACE PIPING PLAN ~UY vr -1• COIIPOmJI ROOFING C»> 15# FB.T ON 5/lf SHfATitNC ON WOOD lRUSS WALL ~~ \ IMlO£L ..lj lf RES J/~ SSP 2 SECTION VIEW 1 . 1/t = 1' 'h"ldD Balllrip F.D.C. DETAIL 1 1H 1'h" SINGlE FH DEPT. OOff£CT10N 2'-6" AF.F. ~ ~ 1 1H :;'i' "' , 1H 1 1H NOTE: PIPING IN CRAWL SPACE TO BE 5' BOD PIPING IN CRAWL SPACE TO BE DYNA-THREAD Galv Piping 3// Galli Woll Plate ~1'-4'+­ A.F.F. Remote Line Of Fire Protection System 3f4"X '11" 45" ill W'ilh Vt" Smooth Bore Orifice INSPECTORS TEST DETAIL 1 1.Hl G DOUBlE F~ Sl1W' 1lPE tW«lER STRAP HANGER PIPE HANGER DETAIL WATER FLOW INFORMATION STATIC PRESSURE: 83 RESIDUAL PRESSURE: 78 P.S.I. FLOWING 1244 GPM . PER : CARBONDALE FIRE DEPT . 0 2:15 P.M . 3-2 -1999 LOCATION : 0 HIGHWAY 133 & COWEN SYSTEM HYDRAUUC DEMAND 1"'1'. ~ HEAD CAI.C \JJ Pressure 61.53 PSI Flowing 108.2 GPM SYSm.t HYDRAUUC DEMAND ...1'-. 1 H£AO CAI.C \JJ Pressure 67 .11 PSI Flowing 87.0 GPW "------------------.--------~---------~--------~--~- friolt ColiniJ SPRINKLER SYMOOL-< 7/1t .II RES lf W11ltl1 HSSW W11ltl1 Wodol l6l :!-l'loco Eoc ~ ..... ~ ffliD IDN'T :V." l:l"ot TEE --+r--:v.· Cl'tt PI'E 2xB stud Wall (2nd fbor Only) 2nd FlOOR HANGER LEGEND A HOOK B COACH SCREW ROD . C C CLAMP D TOP BEAM CLAMP E EYE ROD F FLUSH SHELL G CEILING FLANGE H SIDE BEAM BRACKET ~ XXX lliVAmN A!lll\o£ flNISHEO flOOR A F. F. (;\___ STRUCfUilE 10 COllER ~ UOC Cf Pf£ IN KHB BOD @ CI<.ClllAOON NOD!' II rnooiEil COOPUI«: -SPRINKLER LEGEND • CP.(: PI'E- PIPING DETAIL HA.' "'--:~ :!EX HOO SEL7 TilR'"":J.DINC SCRE'f.' IS r, A!NISHEO Willi THE HANGER AND IS THE MIMt.IUt.l FASTENER SIZE ACCEPTABLE CP'IC SINCL£ F~ER STRAP TYPE HANGER RG. 22 CPVC HANGER PIPE HANGER DETAIL WET SYSTEM LIGHT HAZARD 13R 11 ,168 SQ FT (b ® NEW 4" U.G. \};) ~ ~,l==sr=~=:=~=N= SUPPLY JCI". I I I I 0 1' 2' 4' SCALE I B' ~· CP'IC PI'E 1" ~ Pf[ -1x1 x¥ox¥1" ~ CROSS .... Wodol 2-f'loco Eoc 3/f' JN RES lF Whb SSP SPRINKLER SYIIIIOL-e r u SPRINKLER ORin:;[ SIZES AND T'rl'f 4 l2 SPRAY J' I l J 2 8 16 2 SfiWAU TEMP RATING 0 165" B m o€} 285 ~ ,. :§ m • GlOil[ JN R£S 1F l'l' Mff SSP .l6 155F •I ..0011 IBJ ,..,. WKT < Gl08E JN R£S 1F 7I 1ft W1ff HSSW 31 155F •I ..0011 IBJ ,..,. WKT @o GLOBE .t1 QA 7/l o BRZ SSU 13 286F IDTAL 80 NPS CPVC INSIDE DWIETER APPROVALS REQUIRED OWNERIJ<CH!TECT 3/4" 0.884 ii--QUALITY CONTROL AY: 1" 1.101 I:IYNA-THREAD · ,~ 1---1 ...... • _,.-,-.o8-7--l N .I. C. E.T . 0759 79 GENERAL NOTES 1. All MATERIAL AND EQUIPMENT TO BE NEW AND UNDER WRITERS APPR()II[D. 2. PIPING DIMENSIONS ARE CENTER 10 CENTER EXCEPT RISER & DIMENSIONS SHOWN THUSLY ( 1 -6) WHICH ARE END TO EN D. 3. PIPE HANGERS & MEIHOO OF HANGING TO BE IN ACCORDANCE WllH PAAIPH LET NO. 13. 4. PIPING SHALL 13£ IN ACCORDANCE WITH NFPA PAAIPHL£1 NO . 13. 5. JOINING OF PIPE AND FlTTINGS, THREADED AND WEWED SHALL BE IN ACCORDANCE WITH PAMPHlET NO . 13. 6. OWNER TO PRO'I1DE ADEQUATE HEAT TO PRf.\1:1ff 'WATER IN PI P[S FROM FREEZ ING IN AREAS PROTECTED BY A WET PIPE SPRINKLER SYSTEM. 7. AL L WIRIN G OF ElECTRICAL DEVICES (IF REQUIRED) TO BE PROVIDED BY 01'HERS. B. PAINTI NG OF PIPE AND EQUIPMENT (IF REQUIRED) TO BE PRD'I1DED BY OTHERS. 9. FURRING OF PIPE AN D EQUIPI.IENT (If REQUIRED) TO BE PROVIDED BY OTHERS. REVISIONS MK DA TE BY 1\ 1\ DESIGN CRITERIA: 1. Light Hazard N.F.P.A. 13R 2. Maximum Spacing 18 X 18 In Accordance With Spri nkler Data Sheets . 3. Sprinklers To Be Residential & OR Throughout. 4. 65 G.P .M. Domestic Allowance 5 . Remote Area On Main Floor To Be 4 Most Remote Sprinklers Per N.F.P .A. 13R CONTRACT WITH: PROJECT: THUNDER RIVER LODGE 0179 HIGHWAY 133 , CABONDAL£, COLORADO (970) 963-2543 THUNDER RNER LODGE 0179 HIGHWAY 133 CARBONDALE, COLORADO EXCEL FIRE PROTECTION INC. 536 31 1/2 ROAD, GRAND JUNCTION, COLORADO PHONE: (970) 434-4803 FAX (970) 434-0802 REG. # 99-071 DESIGNER DATE SHEET JOB NO . NKG 3-3-99 1 OF 1 99-1075