Loading...
HomeMy WebLinkAboutApplication- PermitGarfield County ..... I N_o_._w_o_s7 ___ ___, Building & Sanitation Department 1081/1 ' Street, Suite #401 Glenwood Springs, Co. 81601 Office-945-8212 Inspection Line-384-5003 GARFIELD COUNTY BUILDING PERMIT APPLICATION ,, 7 II 12 THIS I'EMII!r BrtOim! troLL AlfD VOID IP WOI!K OR COir.ITRUCTIOH lll11110RIZED IS NOT OOIIIIENCED WlTIILif 180 MY!I, OR, IP CONSTRUCTION OR WORK IS SUSI'I!HDED OR 1\llo\HDOHED POR II PI!RJOD OP 180 01\YS liTANY TilliE APTER WORII: IS COIIIIIEHCED liE REilY CE11'111'Y ntAT lilA VI!: REIID AND I!!XAIIDII!!Dnll! III'PIJCAtt)JII\ND KJIOW TilE 111\111! TO BE TRUE AND CORRECT /IU, PROVI910HS OF LI\WS GClVERHINCI TillS 'ITPB OF WORJO: WILL BE COIII'\.ETED wmiiH 'IIIIIE11li!R SPEC !PIED HER!:IH OR NOT THE ORAHnHO OF A f'ERIIIT DOES NOT PRESUME TO DIY!! lluntOIUn' TO VIOlATE OR CANCEL TilE I'ROVlliiOHS OP AHY 01HER SI'A11! OR I.OCAL LI\W REOUIA1tHO TRUC1tOH OR THE PERPORIIAHCE or L Const. Type: Sclbackft: IS OS No & Fee. _ .. --If-:. SQ.Q..~ AOR!:EII~ PERIIISSION 19 III!REDY DRAinED TO TilE III'I'UCAHT AS OWNER. COKmi\CTORAND/OR Till! AOI!HTOFTIII!i COtn11ACJUR OR OWtfi!IR TO COH$11!UCT Till!: Bn!UcnJRI! AS DI!:'I'AIIZD ON PU\NSAHD l!nC II'K:ATIOIIS SUBIIITT1!D TO 1\HD REVIEWED DYTIII! BUIUliHO DEPARTIII!HT IN COHSlDI!AATION Or nil! IS8SUAHCI!: OP '11118 PllRIIIf. Tlfl! 8fQIQ!R. IIEREBY 110111!:1!:8 TO COIIPLY'III'J1{ AlL IJUIUliiiO CODES liND UNO UBI!: REOUUTIOHS IIDOPTlm DY OIIRPII!lD COumY I'URSUI\Hl"TO 1\UTIIO!Un' OIVI!H Llf 30.:!!1.201 CRS AS AIII!NDI!D. 'ntl! SIONER PURTHI!R 1\0RI!f!S niAT IF TilE IlBOV I! !WO ORDIHI\HCI!S IIIII!: NOTPULLY OOIIPILED WITH JNTHI! LCOI\nDII, I!:RECTIOif, OONSTRIJCTION, AND USE Ol'nlf~ AllOW DEIIClllllED STRUcnJRE, '111E I'ERIIIT lillY IJI! RP:YOKI!D BY H01tCE !'ROll TilE COIJKn' MD TIIATTIIEI'I AND THERI! IT 8111\LL Bf!COIIE HULL AND VOID, TilE ISSIII\NCE OP II I'ERJIT BAllED UPON PIAH9. SPECIPICA1tOIIS.IIJID 01tlf!R DI\Tl\ SH/IU, NOTPREVI!HTTIII! BUIUJIIIO OPPICJAL FRO II TIII!RI!AI'TI!R R~UIRIHO THE CORRI!CTIOff Or I!RRORS IN SAID PIAHS, BPI!CIPICI\TIOIIS AND OTHER Do\TA OR rROII PREVI!H11NCI DUILDIHO OPEAA'IlON BI!IHO CI\RRIED O N THEREUNDER WilEN IN VIOU'IlOH 01' TIIS CODE ORAHY OTIIER ORDIHAHCE OR REOUUnOH Or THIS JURIBDICTIOII. '1111! REVII!W OP BUDIIITTI!D PlANS AND BI'ECIPICATIOIIS AND IH!IPI!CTIOHS CONDUC11!DTIII!REAP'rnR DOES NOT COII!I1TIV11! AN IICCEPTIIHCE OF /\NY RI!SI'OHSJBIU'Ili!S OR UABLmES BY OARFIELD COUNTY POR ERRORS, OIIISSIOffS OR DISCREPENCIES .111E RESPOHSI BILrn' POR 'IllESt!: l'l"niSAND IMPLEIII!IfTl\TIOH DURJIIO CONSTRUC'IlON RESTS SPI!CIPICIIIU.YWmt Till! AR'I1C11!CT. DESIGNER, BUILOI!:R, AND OWNER . COIIIIENTB ARE ~OED TO BE COHSERVII"IIVI! liND 1K SUPPORT OF TilE OWHI!Rs LHTERI!ST T ~ I HEREBY IICKflOWLEDOI! TIIAT IIIII VI! RI!IID AND UIIDERSTIIND 1111! "OREEIIEHT AIIOVJ: (1111T11\4: __ ..L/_...__,_/ ___ _ The following items are required by Garfield County for a final inspection: I. A final El cctrical Inspection from the Colorado Slate Electrical Inspector, 2. Pennanent address assigned by Garfield County Building Department posted where readily visible from access road; 3. A finished roof. a lockable house, complete exterior siding, exterior doors and windows installed, a complete kitchen v.ith cabinets, a sink with hot & cold running water, non-absorbent kitchen floor coverings, counter lops and finished walls, ready for stove and refrigerator, all necessary plumbing: 4. All bathrooms must be complete, with washbowl, tub or shower, toilet stool, hot and cold running water, non·absorbent floors and waits finished and a privacy door; 5. All steps outside or inside over three (3) steps must have handrails, guard mils on balconies or decks over 30" high constructed to all IBC and IRC requirements; 14. Outside grading done to where water will detour away from the building: Exceptions to the outside steps, decks and grading may be made upon the demonstration of extenuating circumstances, i.e. weather, but a Certificah: of Occupancy will not be issued until all the required items arc completed and a final inspection made: 8. A final inspection sign off by the Garfield County Road & Bridge Department for driveway installation, where applicable; as well as any final sign olfby the Fire District, and/or State Agencies where applicable. A CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED . ••••cANNOT OCCUPY OR USE DWELLING UNTIL A CERTIRCA TE OF OCCUPANCY (C.O.) IS ISSUED. OCCUPANCY OR US E OF DWELLING WITIIOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. I understand and agree to abide by the above conditi o ns for oceupa~~ll~ _!ll d the iss uance of a Certificate of Occupancy for the dwelling under building permit I 0'0':5.._;2- ~~1.. . ±:Leta& Signature ~ Dil le Bpapplicationfeb2006 VALUATION/FEE DETERMINATION Applicant~ Address i/ Date 7.. - Finished (Livable Area): Main Upper Lower Other Basement: 1410 1w Total Square Feet Valuation Unfinished Conversion of Unfinished to Finished Plan Check Fee for Conversion Valuation Valuation Ct~ 't {~ Crawl Space: Valuation lftO 'I~ Decks/Patios: Covered Valuation ?.?2. .,.l!f Open Valuation Total Valuation ~' rs-+-rt\ Subdivision~lt')Yf:Jft<lj' Lot/Block 17 Contractor D -~· -- tetf~ frQrvti~ /71 ~55 zo I Ljg 7?/LoN --rRA1L Pll.eAc.llt.J-t-,r/ CO GARFIELD COUNTY BUILDING AND PLANNING t?'j("' ~ ~"" 970-945-8212 0 1 u;J ..::> .:> MINIMUM APPLICATION REQUIREMENTS For SINGLE FAMILY DWELLING CONSTRUCTION Including NEW CONSTRUCTION ADDITIONS ALTERATIONS And MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. When reviewing a plan and it's discovered that required information has not been provided by the applicant, this will result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor shall be required to provide this information before the plan review can proceed. Other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. Any project with more than ten (10) occupants requires the plans to be sealed by a Colorado Registered Design Professional. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following checklist prior to and during design. Applicants are required to indicate appropriately and to submit the completed checklist at time of application for a permit. Plans to be included for a Building Permit, must be on drafting paper at least l8"x24" and drawn to scale. Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with I decks, balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line and original grade. A section showing in detail, from the bottom of the footing to the top of the roof, including re-bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house-rap, (which is required), siding or any approved building material. Engineered foundations may be required. A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. wind speed, wind exposure B or C, and a 36 inch frost depth. All sheets to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be incompliance with the 2003 IRC. 1. Is a site plan included that identifies the location of the proposed structure or addition and distances to the property lines from each comer of the proposed structure(s) prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Properties with slopes of30% or greater must be shown on the site plan. (NOTE Section: 106.2) Any site plan for the placement of any portion of a structure within 50 ft. of a property line and not within a previously surveyed building envelope on a subdivision final plat shall be prepared by a licensed surveyor and have the surveyor's signature and professional stamp on the drawing. Any structure to be built within a building envelope of a lot shown on a recorded subdivision plat shall include a copy of the building envelope as it is shown on the final plat with the proposed structure located within the envelope. Yes--fr-- 2. Does the site plan also include any other buildings on the property, setback easements and utility easements? Please refer to Section 5.05.03 in the Garfield County Zoning Resolution if the property you are applying for a building permit on is located on a comer lot. Special ~:cx ·pply. 3. Does the site plan include when applicable the location of the I.S.D.S. (Individual Sewage Disposal System) and the distances to the property lines, wells (on subject property and adjacm~es), streams or water courses? Yes 2 4. Does the site plan indicate the location and direction of the County or private road accessing the propertY? Yes '(.,( 5. Do the plans include a foundation plan indicating the size, location and spacing of all ~:forcin)l..eel in accordance with the IRC or per stamped engineered design? 6. Do the plans indicate the location and size of ventilation openings for under floor crawl i'~ces an.x:e clearances required between wood and earth? 1. Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces and soffits? Yes 'k 8. Do the plans include design loads as required by Garfield County for roof snow loads, (a minimum of 40 pounds per square foot up to & including 7,000 feet above sea level), floor loads and wind loads? Yes \j 0- 9. Does the plan include a building section drawing indicating foundation, wall, floor, and roof constructior(! .r Yes __ ....,. 7 X<........l., __ _ 10. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or joists or trusses? Yes X ) 11. Does the building section drawing or other detail include the method of positive connection ~:;1 coi')C'd beams1 12. Does the elevation plan indicate the height of the building or proposed addition from the undisturbed grade to the midpoint between the ridge and eave of a gable or shed roof or the top of a flat roo . (Building height measurement usually not to exceed 25 feet) Yes -----::::""""""....;:..... __ 13. Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase II certifications or phase II EPA certification? Yes No )< -,(,.:;........;..___ __ _ 3 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the IRC? ~ Yes No __ 7~~~=----- Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements comply with the requirements of the IRC? Yes >"-No ______ _ Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable rooms? Yes )< No __________ __ 7 Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specifY safety glazing for these areas? Yes ~ No _________ _ 7 Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? Yes I..L No ______ _ / Do you understand that if you are building on a parcel of land created by the exemption process or the subdivision process, are building plans in compliance with all plat notes and/or covenants? Yes )< No ______ _ Do you understand that if you belong to a homeowners association, it is your responsibility to obtain written permission from the association, if required by that association, prior to submittinz: an application for a buildinz: pennit? The building permit application will not be accepted~wi~out it. Yes .>C No ------- Will this be! only residential structure on the parcel? Yes .~ No Ifno-Explain: ______ _ Have two (2) complete sets of construction drawings been submitted with the application? Yes ,X. Do you Wlderstand that the minimum dimension a home can be on a lot is 20ft. wide and 20ft. long? Yes .Y No 7 ' ----- 4 24. Have you designed or had this plan designed while considering building and other constructi~n ~code requirements? Yes X No _____ _ 7" 25. Do your plans comply with all zoning rules and regulations in the County related to your properties zone district? Yes 'j.._.. No. _____ _ 26. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by the Garfield County Building Department? Yes X No ____ _ 7'- 27. Do you understand that approval for design and/or construction changes are required prior to the applJsation of these changes? Yes J<.. No _____ _ I 28. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application submittal and that you will be required to pay the "Permit Fee" as well as any "Road Impact" or "Septic System .. fees required, at the time you pick up your building eegnit? Yes X. No _____ _ I 29. Are you aware that you must call in for an inspection by 3:30 the business day berore the requested inspection in order to receive it the rollowing business day? Inspections will be made from 7:30 a.m. to 3:30 p.m. Monday through Friday. Inspections are to be called in to 384-5003. Yes X No ____ _ 7 30. Are you aware that requesting inspections on work that is not ready or not accessible will result in a 5 00 re-inspection fee ? Yes No _____ _ 31. Are you aware that you are required to call for all inspections required under the IRC including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of the building? YesX No _____ _ ( 32. Are you aware that the Permit Application must be signed by the Owner or a written authority being given for an Agent and that the party responsible for the project must comply with the IR«;?. Yes 'X No _____ _ /' s 33. Are you aware that prior to submittal of a building permit application you are required to show proof of a driveway access permit or obtain a statement from the Garfield County Road & Bridge Department stating one is not necessaty? You can contact the Road & Bridge Department at 625-8601. Yes ':L No ~ ----- 34. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups. unless you as the homeowner are performing the work? The license number of the person performing the work will be required at time of applicable inspection. Yes 7 X... No ______ _ 35. Are you aware. that on the front of the Building Permit Application you will need to fill in the Parcel/Schedule Number for the lot you are applying for this permit on prior to submittal of a building permit application? Your attention in this is appreciated. Yes X No ? -------- 36. Do you know that the local fire district may require you to submit plans for their review of fire safety issues? Yes No ~ (please check with the building department about this requirement) 7 37 . Do you understand that if you are planning on doing any excavating or grading to the property prior to issuance of a building permit that you will be required to obtain a grading ~e:it? )( I . I hereby acknowledge that I have read, understand and answered these questions to the a ·~ «><?-t) "' ~er · Date Phone:_?/:;J .. /p¢9. J,.Q(o 3 (days)~ (evenings) ProjectName: ~ ~ ~~~ Project Address: L/g L?lb, 1\) 7'RA J L /J1£4c..flt.J fE) C..o , Notes: lfyou have answered "No" on any of the questions . you may be required to provide this g /Ce,Jc information at the request of the Building Official prior to beginning the plan review process. " Delays in issuing the permit are to be expected. Work may not proceed without the issuance of a permit. Ifit is determined by the Building Official that additional information is necessaty to review the application and plans to determine minimum compliance with the adopted codes. the application may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first 6 position for review, delay in issuance of the permit or delay in proceeding with construction. BpminreqFeb2005 7 PLAN REVIEW CHECKLIST Applican~OO ~~J:trn't'!W~i¥!nnm it _0u'rveyed Site Plan Jf.ls;:::; Permit and Setbacks __ '-1];._ raaddee1ffopography 30% -~ach Residential Plan Review List ~inimum Application Questionnaire ~ivision Plat Notes ~Fire Department Review ~luation Determination/Fees ~ne Plans/Stamps/Sticker ~ach Conditions ~plication Signed ~Reviewer To Sign Application ~/Schedule No. rl.:tf.. ~Snow load Letter-Manf. Hms. --'V"'---_ S Saoils Report GENERAL NOTES: Line Setbacks -~Zoning Sign-off --+-Road Impact Fees -t--HONDRC Approval ,__~Gradeffopography 40% __ Planning Issues _Subdivision Plat Notes • ,, Lo-r if7 EAGLES POINT ARCHITECTURAL COMMITTEE APPLICATlON SUBMITTAL FORM (For New Home Construction) INSTRUCTIONS: This Application & Check1ist is to be used for all project submittals to the Eagles Point Architectural Conunittee (EP/AC). This form is intended to assist in ensuring that the application submittal is complete. This wi11 help provide a quicker, more thorough review process. It is recommended that each Applicant thoroughly review the requirements of the current Architectural Standards, the DecJaration of Covenants {including Resolutions) and the recorded Final Plat prior to preparing a submittaL Applicants preparing a submittal should compare the information they are about to submit with the requirements of this form and Acheck off@ each required item on the form. If any item is not checked, the Application submittal is not complete and should not be submitted. Incomplete Applications will not be processed and will be returned to the Applicant. In addition to the checklist, Applicants should fill in all of the places on the Application Form where information is requested. The Architectural Committee wi11 use this information in evaluating your Application. If information is requested but is not applicable to your specific project submittal, write 'AN/A@ in the space provided. If some required information is yet to be determined (such as exterior paint colors you may not have yet selected) write A TBD@ in the appropriated space provided. You will then be required to make a fo11ow-up submittal with these selections at a later date but before installation in the home. DO NOT fill in any information in the AConditions for Approval@ section of this form. This portion of the fonn is for Architectural Corrunittee use only. 'When an Application is complete, please mail or deliver it to the following address: Eagles Point Architectural Corrunittee Application 73-G Sipprelle Drive P.O. Box 6006 Battlement Mesa, Colorado 81636 Please contact Jane Chapman at (970) 285-9740 to confinn the next scheduled meeting date or to request further information. We thank you in advance for your cooperation and in complying with the Architectural Standards of Eagles Point. AdoptLd anti Ejf~criv~ Augu$1 1, 1004 11111111111111111111111111111111 11111111111111111111111 660192 09/22/2004 11:24~ 81624 P379 M ALSDORF .. J._....~...)L_ 2 . Architectural Drawings (1/4" = 1' or 1/8" = 1' scale) with the fo11owing infonnation shown. =-# Floor Plan(s) wi th overa11 dimensions (fill -in the following square foot areas). First Floor Fin ished Living Area: Second Floor Finished Living Area: Lower Floor Finished Living Area: Total Finished Living Area: Total Unfinished Living Area: Garage Area: I '+ 1 o square feet 4 g 0 square feet ·i:::JC . .>c . square feet / 2? "'10 square feet ·-square feet (2 $' 'f square feet Building Elevations Plans indicating doors, windows, exterior materials, building height, roof pitch, roof-mounted evaporative coolers, etc. (fi11-in maximum height below). MIDCirnum building height to highest ridge line or building structural projection ____ feet above top of street curb at front-center of your lot . Engineered (stamped) Foundation Plan. Outbuildings indicating dimensions, elevations and overalJ height to ridge line. 3. Exterior Materials (.fiJJ-in the selections below): Roofing Material: l?.c'1 $ ?>0 v i1?. '1&&/·' Ale. Color: _......~o::R<z~'(,~:;..:~'~w~\'J..k....;=G:::;..L:g:::::r;~y~­ Primary Siding ' rlaterial: toJor: Accent Siding Material : _________ Color:---------- Trim Material : Color: Masonry Material: Color: -------------:j Stucco Materials: .:J)g.y ~tlrr u \6?A1 Afj}uJq Color: or.:-r-Wii q€ k;~., h r I 7 11.¥-Y' Front Door Material : .::; r €f!''L I Er f?iZ£(MsColor: --~..L....:!~/L.,_ ____ _ Garage Door Material : 57-ree r..-Color:---------- COLOR SAMPLE COLOR SAMPLE COLOR SAMPLE COLOR SAlvfPLE COLOR SAMPLE COLOR SAMPLE Atiopud anti Efftctivt August 2, 2004 1111111111111111111 Jlllllllllllllllllllllllllllllllllll ~~~1~? ~~/??/?~A4 11:24A B1S24 P3B1 H QI~OORF ' ;Failure to pay fines Jevied as determined at the Hearing may also resu1t in a Lien being placed on your Property or litigation Process initiated by the Eagles Point Board of Directors to secure conformance with this fuJI Application and its respective Conditions Of Approval. I/\Ve understand that Architectural Committee approval does not constitute approval oftbe local building department, drainage design or structural soundness, nor does it constitute assurance that the plans comply with an applicable codes, regulations, ordinances and laws. J!\Ve further acknowledge that any subsequent field changes which I/We may desire to the Home Construction or Improvement Projects of this original Application Submittal and the original Conditions of Approval issued by tbe EP/AC wm require an additional Revised Application Submittal on our behalf, and tbatli'Ve wiJJ not proceed with any subsequent field changes until a Revised Conditions of Approval have been issued to us by tbe EP/AC. Owner=s Signature(s): --=..Lz.....:;;;..~_.;.:..· ---,--j"--....:..~..=~..;;.._-· -~-------- Owner=s Printed Names: . z;;", 7-# / Poev Date: ;z-,?;2-()cS? Date: Builder=s Signature: ~~ ~ // ~4 t2-z7!1)/ /l~y ;?-r2J -oc:o Builders Printed Name: Date: i This portion of the AppHcation Form is to be completed by the Architectural Committee (not the Applicant). Adopud tmd Eff~cti~ August 1, 200~ 11111/lll///llllllflll 1111111111 1111111 Ill 1111/lllf 1111 660192 09/22/2004 11 :24A 81624 P383 M ALSDORF I I .. ~-... Lo~ Lf I AS PER THE ARCHITECTURAL ST ANDARDS,PLEASE INDICATE THE FOLLOWING POINTS ON THE PLOT PLAN AND BELOW: ELEVATIONS AT EACH CORNER OF THE LOT. _LOCATION. l. 2. 3. 4. 5. 6.--THE HIGH POINT OF THE LOT. 7.--THE LOW POINT OF THE LOT. &.--HEIGHT OF GARAGE FLOOR 9.--HEIGHT OF HOUSE MAIN FLOOR 1 0.-HEIGHT OF ROOF ABOVE FOUNDATION. ( MAXIMUM---35 FEET) 11.--HEIGHT OF ROOF ABOVE CENTER OF THE :MID CURB. ( MAXIMUM---29 FEET) ELEVATION ( FEET ) -----t ~11 - 0 -2- -I£- ,..--I 1'0 {_ - 0 -=--'-- ,rP L -· -·· - tt'.!2- -Z ____ ::s, ~ ./ .) z ¥·- 12.~-DRAINAGE FLOW LINES ON THE PLOT PLAN. 13.--ROOF PITCHES.--------1.------------ ~/ ~ 2.-------------/, zc _________ _ 4.------------- 15 .--SQUARE FEET OF LIVING SPACE. )~Z~ ---------~-~--------- \ (I) X m !:!1 .... i ~ lW 8 DO [§~~~ l!:.@ij' ~d' §~]'if'§ ~ ID • . -...--.-vva "~ JC~ m t•m' , ... _.,..,. ~tech HEPWORTH ' ' \ • AK c;EOTP 1-.r , RECEIVElfecember 3o. 2nos t_,+ Lj 7 3 LOOG Tim Perrv JUL 0 7422 So~th Tcllunde Ctrcle GARFii::L. ....... ~. .... uNTY Foxfield, Colorado 80016 BUILDING & PLANNING i.u. ( ;l ••h•, t 111n . lu~ I ,,, I 't · , -. l , .t"' • !, , 'It•~,· i .......... h IJ •• Ill Job No.106 0077 Subject: Subsoil Study for Foundation Destgn. Propos ed Residence, Lot 47, Eagles Point at Battlement Mesa, Talon Trail. B a ttlement Mesa. Colorado. Dear Mr. Perry: As requested, Hepworth-Pawlak Geotechnical. Inc. performed a s ubsoil study for design of foundations at the subject site. The study was conducted in accordance with our agreement for geotechnical engineering sen·ices to you dated December 9, 2005. The data obtained and our recommendations based on the proposed construction and subsurface conditions encountered are presented in this report. Hepworth-Pawlak Geoteclmical. Inc. previously performed a preliminary geotechnical study for development of the subdivision and presented our findings in u report dated November 21 , 2003 , Job No. I 03 680. Proposed Construction: The proposed residence will he a two story wood frame structure with an attached garage localed on the site between the exploratory pits shown on Figure I . Ground floor will be structural over a crawlspace tor the residence and slab· on-grade in the garage. Cut depths are expected to range up to about 3 feet. Foundation loadings for this type of construction are assumed to be relatively light and typical of the proposed type of construction. If building conditions or foundation loadings arc sigmficantly d i fferent from those described above, we should be notified to re·C\'aluatc the recommendations presented in this report. Site Conditions: The site was v acant at the time of our tield exploration. The ground surface of the lot is relatively flat. The vegetation has been remo\'ed from the lot. Subsurface Conditions: The subsurfac e conditions at the site were evaluated by excavating two exploratory pits at the approximate loc ations shown on Fibrure 1. The logs of the pits nrc presented on Figure 2. The subsoils encountered, below about 1 toot oftopsoil and 1 to 2'h ofmedtum stiff, sandy clay and silt. consist of relatively dense, (', -2- basalt !:,'Tavel. cobbles and boulders in a sandy clay matrix t o the pit depths of2'l'2 to 4~ feet. Results of swell-consolidatio n resting perfimned on a relatively undisturbed sample of the clay. presented on Figure 3. indicate low compressibility under existing moisture conditions and light loading and a minor expans10n potential when wetted. No free water was observed in the pits at the time of excavation and the soils were slightly moist. A boring drilled to the east of the lot as part of the preliminary study encountered about 5Yl feet of clay soils O\'erlying the ba'\alt rock soils and no groundwater to the drilled depth of 12 feet in Octob er 1003 . Foundation Recommendations: Considering the subsoil conditions encountered in the exploratory pits and the nature of the proposed construction. we recommend spread footings placed on the undisturbed natural soil designed for an allowable soil bearing pressure of 1 ,500 psf for support of the proposed residence. The clay soils in the area tend to have variable settlement/heave potential when wetted and there could be some post- construction foundation movement if the bearing soils become wetted. Bearing entirely on the basalt rock soils will help mitigate the pot~ntial expansiorusettlemcnt of the clay soils. The settlement/heave potential should be further e\'aluated at the time of construction. Footings should be a minimum width of 18 inches for continuous walls and 2 feet for columns. The topsoil and loose disturbed soils encountered at the foundatwn bearing level within the excavation should be removed and the footing bearing level extended down to the undisturbed natural soils. Voids created by the removal oflarge rocks should be backfill with compacted sand and ~'t'avel, such as road base, or with concrete. Exterior footings should be provided with adequate cover above their bearing elevations for frost protection. Placement of footings at least 36 inches below the exterior grade is typically used in this area. Continuous foundation walls should be reinforced top and bottom to span local anomalies such as by assuming an unsupported length of at least 12 feet. Foundatio n walls acting as retaining structures should be designed to resist a lateral earth pressure based on an equivalent fluid unit weight of at least 50 pcf for the on- site soil, excludin g v egetation. topsoil or oversized rock. as backfill. Floor Slabs: The natural on-si t e soils. exclusive of topsoil, are suitable to support lightly loaded slab-on-b'l'ade construction. The clay soils have 'ariable settlement/heave potential which co uld result in some slab movement if the bearing soils become wetted. To reduce the effect s of some differential movement, floor slabs should be separated from all bearing walls and co lumns with expansion joints which allow unrestrained vertical movement. Floor slab control joints should be used to reduce damage due to shrinkage cracking. The requirements for joint spacing and slab rei nforcement should be established by the designer based on experience and the intended slab use. A minimum 4 inch layer of sand and gravel. such as r oad base should be placed below interior slabs-on- Job NCI .I 0(, 0077 ... --~ - ~'fade as a leveling course and for subgrade suppon. This material should consist of minus 2 inch aggregate with Jess than 50% passing the "''o . 4 steve and Jess than 12% passing the No. 200 sieve. All fiJI materials tor support of floor slabs should be compacted to at least 95% of maximum standard Proctor density at a moisture content near optimum. Required fill can consist of the on-site soils devoid of\·egetation. topsoil and oversized rock. Surface Drainage: The followmg drainage precautions should ht! observed during construction and maintained at all times after the residence has been completed: I) Inundation of the foundation excavations and underslab areas should be avoided during construction. Drying could increase the expansion potential of the clay soils. 2) Exterior backfill should be adjusted to ncar optimum moisture and compacted to at least 95% of the maximum standard Proctor density in pa,·cment and slab areas and to at least 90% of the maximum standard Proctor density in landscape areas. 3) The ground surface surrounding the exterior of the building should be sloped to drain away from the foundation in all directions. We recommend a minimum slope of 6 inches m the first 1 0 feet in unpaved areas and a minimum slope of 3 inches in the first 10 feet in pavement and walkway areas. 4) Roof downspouts and drains should discharge well beyond the limits of all backfill. 5) Irrigation sprinkler heads and landscaping which requires regular heavy irrigation, such as sod, should be located at least 5 teet from foundation walls. Limitations: This study has been conducted in accordance with generally accepted geotechnical engineering principles and practices in this area at this time. We make no warranty either express or implied. The conclusions and recommendations submitted in this report are based upon the data obtained from the exploratory pits excavated at the locations indicated on Figure 1 and to the depths shown on Figure 2, the proposed type of construction, and our experience in the area. Our sen·ices do not mclude determining the presence, prevention or possibility of mold or other biological contaminants (MOBC) developing in the future. If the client is concerned about MOBC, then a professional in this special field of practice should be consulted. Our findings include interpolation and extrapolation of the subsurface conditions identified at the exploratory pits and variations in the subsurface conditions may not become evident until excavation is perfonned. If Job t\o. I 06 Oll77 -4- conditions encountered during construction appear dlfrerent from those described in this report, we should be notified at once so re-evaluation of the recommendations may be made. This report has been prepared for the exclusive use b y our client for design purposes. We are not responsible for technical mterpretations by others of our intbnnation. As the project evolves, we should provide continued consultation and 1ield services during construction to review and monitor the implementation of our recommendations, and to verifY that the recommendations have been appropriately interpreted. Significant design changes may require additional analysis or modifications to the recommendations presented herein. We recommend on-site observation of cxcavatwns and foundation bearing strata and testing of structural fil) by a representative of the geotechnical engineer. Ifyou have any questions or if we may be of further assistance. please let us know. Respectfully Submitted, Jordy Z. Adamson. Jr .• Reviewed by: Steven L. Pawlak. P .E . JZA!ksw attachments Job ~'''·106 (Kl77 Figure 1 -Location of Exploratory Pits Figure 2-Logs of Exploratory Pits Figure 3 -Swell-Consolidation Test Results Table 1 -Summary of Laboratory Test Results APPROXIMATE SCALE 1. = 20 ~~ TALON TRAIL -- -- r---------------, I I I • PIT 2 I I I I I I I I I I I I I I I I I I I I I I I I I I LOT 47 I I I I I LOT 48 I I I I LOT46 I I I I I I I PIT 1 • I I I L--------------__l -- LOT 49 106 0077 o&-'&tech LOCATION OF EXPLORATORY PITS Figure 1 Heoworth-Pawlck Geottchnlcal 0 5 10 LEGEND: ?T1 LOT47 PIT 2 ~~ WC =103 DD-=88 -200 =85 g TOPSOIL; sandy silt and clay, organics. ftrrn, slightly motst brown 0 5 10 D CLAY AND SILT (CL-ML): sandy, medium stiff. slightly mo1st, brown, calcareous , low to medium p lasticity . BASALT FRAGMENTS (GM-GC); m a sandy silt to sandy clay matnx. with cobbles and boulders, dense , slightly moist, mtxed brown, slightly to moderately calcareous ~ 2" Diameter hand driven liner sample. f -: Disturbed bulk sample ~-~ NOTES: 1. Er.ploratory pits were excavated on December 21, 2005 with a trackhoe . 2. Locations of exploratory pits were measured approxtmately by pacing from features shown on the site plan provided. 3. Elevations of exploratory pits were not measured a.,d the logs o ~ exploratory pits are drawn to depth. 4. The exploratory pit locations should be considered accurate on ly to the deg1ee imphec by the method used. 5. The lines between materials shown on the exp oratory p1t ~ogs represent the approximate boundaries between material types and transitions may be gradual . 6. No free water was encountered tn the pits at the time of excavat 1ng. Fluctuation in water level may occur with time . 7. Laboratory Testing Results: WC =Water Content(%) DD = Dry Density (pen -200 = Percent oassing No . 200 sieve G~ H wortn-Powlak Geotltc:l'lnlcol 106 0077 LOGS OF EXPLORATORY PITS Figure 2 Moisture Content = 10.3 percent Dry Density = 88 pcf Sample of. Sandy Silty O ay From : P1t 2 at 3 Feet Lot 47 I '#- § 0 ·u; I<!>--a ~~ ~ ~ 1 11... I Expansion "~p .§ fl) upon &1 2 wetting a. g u 01 1.0 10 100 APPLIED PRESSURE -ks1 106 0077 ~ SWELL-CONSOLIDATION TEST RESULTS Figure 3 H•i•ortn-Pawlak G«<technlcal COUNTY OF -GARFIELD -BUILDING PERMIT CORRECTION NOTICE 108 8th St., Suite 401 Glenwood Springs, Colorado Phone (970) 945-8212 Permit No. !OO..f" 7 I have this day inspected this structure and these J Jim~~he f J:;ni~c~d: g) /-~~an~ 6to2- 1 )/.( ~ ;-:z_ r)L You are hereby notified that the above correction must be inspected before covering. When corrections have been made, call for Inspection at 970.384·5003. Date 3-1'/ 20.!2..2__ --·•ilding Inspector -----"'=!ll~-~ ....... k-·J,....._~......,_.-"-'----------­ ... "'\ 945-8212 COUNTY OF GARFIELD -BUILDING PERMIT CORRECTION NOTICE 108 8th St., Suite 401 Glenwood Springs, Colorado Phone (970) 945-8212 Job located at t?t?zi' M~ 74"'-&j:_, Permit No. / !JOS7 You are hereby notified that the above correction must be inspected before covering. When corrections have been made, call for Inspection at 970·384·5003. Date :sh-o 20 ~ Building lnspec'r ~;?/ Phone (970) 945-821 2 COUNTY OF GARFIELD -BUILDING PERMIT CORRECTION NOTICE 108 8th St., Suite 401 Glenwood Springs, Colorado Phone (970) 945-8212 /0 ~ ,.,, ,-,. Job located at _(_1.;..._( .. _.;......;'7,;.:;..~:_---'1'--;;.;...t?....;;!~;..;..?_-·_1 ....;.--r;_/l_,_f'{,_L ___ _ Permit No. _____ /_~~!~=~~----~~-------------------- I have this day inspected this structure and these premises and found the following corrections needed: .---, .~,-:· . / I '1 /t-? ,, I C.,t·l~ I -t ~~ IJ e,y~ rJ-t' /tr · I o(j. 1) • _ /} c:--L·ff71 -,._ ;?-"" ;: r 1 L"u"'.z.-c.---. ;' I ·YJ . ·"' L / ,_ I _ _;, t''~) . . J. if.. /) 01 "\ .:--, I You are hereby notified that the above correction must be inspected before covering. When corrections have been made, call for Inspection at 970·384-5003. J -. I /' .-l Date------------20 . ..:..• -::---..,--- /. . / / " I ·? .'1 J, Building Inspector ----=-~t.:..:/:.;....,:.;...., _'...:..I' __ " __ L·_~ _f..(-_.;;..?1'"""': _______ _ Phone (970) 945·8212 No. ~/{)D-~___,7'---- 1 t:O ..-1 ~ /) pUILDINQ PER~IT CARD Job Address "1"/!l ~ o<'Yif'-11 Owner ~ ...dc-kM.~ Contractor &'7J ~~ Setbacks: Front Rear RH _____ LH _____ Zoning ----- SfF c:JY\ O-tt~~ wf~'\l,~NSPECTIONs SoiiJ Test ~T~ . Weatherproofing Footing 9-2 '1--" IT a-Mechanicai _____ ......,.,_,,....,.--..,.--~,---- Foundatlon q:'b~-=ro Electrical Rough (State) ~ ~ -o'1 Grout Electrical FinaljState)......:..f~·-=~~-;~'=:F--......... ,.........,- Underground PlumbWg Finallf-/'~~0 7 /Checklist Complet Rough Plumb,..lng ::2-Z-~en; Certificate Occupancy # ~'S:;~~gq~----- Framing .:S-z.J' o 1 ~ Date ---=\~\-_\.._::3 ..... --'o;:;.~....,._ _____ _ Insulation ]-"l.-'Z..,D1 W.. Septic System *-=SQe=:~......:.~.x.=::....;;..:. ______ _ Roofing . Date ------------- Drywall ?(~If -o 1 ldJ'!J .. Fina1---...,...-------- Gas Piping ~-Z. • lrJ£ih\l\ OtheJ""l\""'• +'f-.... .... J.t"'"'~-=t-=Al91r-::A......_ ______ _ ~~ ~~-~ ~ 'f-NOTES ~~~·~~~~ ~C.o. •X'ORIOR ~~~·-------------------- Drainage -------------- Oec~suppon & c:leerance to wood ------- Decks-slllnl & ralla ----------- Exterior loc:ka ----------- Flashing around door~~ & windows _____ _ lnHC:I sc:reens __________ _ INTERIOR GARAGE Fire wall aeparatlon ____________ _ Service doo,...1~·· min . ________ _ Door (20 mln 1 w/auto c:loMr·t~·· min. ____ _ Mach. equip. 18" above floor _______ _ ~opening Into sleeping are•------- BASEMENT ·CRAWL AREA Acc:esa ______________ _ inautatlon -------------- Haedroom/Stalrs __________ _ Ventilation ------------ FINAL CH.CKLIST MECHANICAL ROOM Bd~--------------Hot water _________ _ F.A. gil/oil ________ _ Floor drain ________ _ Clearance _________ _ Air con . system, _______ _ Hot watll' heater -------- Combuallon air _______ _ Gas piping, valves _______ _ LPG Drain --------- FIREPLACE/STOVE Cleerance to combuallbtea ____ _ Termlnallon ol chimney _____ _ Combuellon •-------- Hearth (1 2'' or 20 ' on lldHI ----- Giass doOrs ________ _ Certified by: ________ _ REMARKS (continue on back) STAIR'NAYS . Headroom (8'6"1 --------- Railing & guardraira ·----------- W~h -------------- Alae & run ------------- KITCHEN Clear~nce above grill ______ -:-_ Exhauat fan ---------- Broiler exhauat (1 tv. chasai ------ BEDROOMS Egress ____________ _ Smoke detector ---------- BATHROOMS Exhaust fan _________ _ Shlltterproof glass _________ _ OTHER ,. .. t ' INSPECTION WILL NOT BE MADE UNLESS THIS CARD IS POSTED ON THE JOB 24 HOURS NOTICE REQUIRED FOR INSPECTIONS BUILDING PERMIT GARFIELD COUNTY, COLORADO Date lssuedZ\~ .. Zoned Area ••••••••••••.•••••••••••••.• Permit No •.• ./®$...7, ........ . AGREEMENT In consideration of the issuance of this permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the mning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building Inspector and IMMEDIATELY BECOME NULL AND VOID. i; Tbis Card Must Be Posted So It is Plainly Visible From Tbe Street Until Final Inspection. INSPECTION RECORD Footing Driveway Insulation 3-'J... Z --07 ~ Drywall -1/--0? ~ THIS PERMIT IS NOT TRANSFERABLE For Inspections Call384-5003 108 8th Street Glenwood Springs, Colorado APPROVEDDO NOT DESTROY THIS CARD Data~/ ~~ICED OUTSIDE-c ~fWITH CLEAR PLASTIC Parcel Detail Page 1 of 3 Garfield County Assessor/Treasurer Parcel Detail Information Assessorffreasurer Pror-ecry Search I Assessor Subset Query I Assessor Sales Search CJerk & Recorder Recer-ti on Se arc h Basic Building Characteristi c s I I~InformatioQ Parcel Detail I Value Detail Sales Detail I Residen ti al/Commerci al Improvement Detail Land Detail I Photograph s I Tax Area II Account Nu mber II Parcel Number II Mill Levy I I 080 II R0422 15 II 240717211047 II 51.771 I Owner Name and Mailing Address IPERR Y, TIMOTHY T I 17422 S TELLURIDE CT I !FOXFIELD, CO 80016 I Legal Description lsECT,TWN,RNG:17-7-95 SUB:FIRST !EAGLES POINT LOT:47 PRE:R770006 IBK:0735 PG:0142 BK:0601 PG:0658 IBK: 1773 PG:85 RECPT:692523 BK: 1763 IPG:42 RECPT:690211 BK: 1624 PG:286 IRECPT:660189 BK:l703 PG:330 IRECPT:677438 BK: 1703 PG:327 IRECPT:677437 BK: 1668 PG:443 IRECPT:669853 BK: 1650 PG:358 IRECPT:665807 BK:1650 PG:355 IRECPT:665806 BK:1636 PG:378 IRECPT:662798 BK: 1624 PG:389 IRECPT:660193 BK:1624 PG:306 IRECPT:660192 BK:1624 PG:288 IRECPT:660190 BK:1615 PG:504 IRECPT:658359 BK : 1604 PG:906 http ://www .garcoac t.c om/asse ss or/parce l.asp ?ParcelN um be r=240717211 04 7 8/4/2006 Parcel Detail IRECPT:655941 BK:1575 PG:7 IRECPT:649590 BK: 1575 PG: 11 IRECPT:649591 BK:0780 PG:0729 IBK:0780 PG:0722 BK:0780 PG:0718 IBK:0773 PG:0475 BK:0769 PG:0647 IBK:0769 PG:0643 BK:0769 PG:0639 IBK:0769 PG:0518 BK:0729 PG:0231 Location Physical Address: IIPARACHUTE Subdivision: IIFIRST EAGLES POINT Land Acres: llo Land Sq Ft: lltO,l13 Section II Township II Range 17 II 7 II 95 I Property Tax Valuation Information Actual Value II Assessed Value I Land: 14,79011 4,2901 Improvements: oil ol Total: 14,79011 4,2901 Sale Date: 112114/2006 Sale Price: 1152,700 Basic Building Characteristics Number of Residential lo I Buildings: Number of Commllnd lo I Buildings: No Building Records Found Tax Information Tax Year II Transaction Type II Amount I ?=====================~~========~! 2005 II Tax Payment: Whole II ($29.50)1 IF=======~u~=================~uFI======~,~ http ://www .garcoact.com/assessor/parcel.asp?Parcel Number=240717211 04 7 Page 2 of3 8/4/2006