HomeMy WebLinkAboutApplication - Permit~ 1
Garfield County
t, Btiilding & Sanitation Depmtment
108 8 1
' Street, Suite #201 Glenwood Springs, Co. 81601
Office-945-8212 Inspection Line-384-5003
I NO. 9\39
JobAddress 8'~ .f6&&J>Mas:B ~&S ,~~~ (b 8.(623
Nature of Work Buildigf Permit 'h:J ~ UseofBuilding=~IIOff{~:!ZC*~~
Owner Gp;rac. 5. J.{,L i'Y c:t:= -Grcley.
Contractor Q.vJJ.Jidl '4 &/,.,.,..· ~ (TJf/1' f.J{V S -.---..rr-...-j,#~
Amount of Pennit $ /7 95./3 -f-0tJ~~ 86ate_~r::....'"---=-l.:..._). o_d....t..__ ___ _
7 {~(~)-~ ~~Clerk !J..tf2
~ o~~.:n~:Jrcr
-._.
--
Apr 10 04 09:58a
J p . 1
GARFIELD COUNTY BUILDING PERMIT APPLICATION
1•8* Stnet,Sute 211, Gt-oed Sprillp, CO 11"1 ~ 3 03
Pkae: !)70-9&UIZ I Fac: "t-3UoU1ll /l~~~p.cdoa Llll•: 1nC>.JI4-5tll3 I -
Pcnnlt No: cp J 39 ParceiJSdac4111e N~ 'iji! be; Z
35""/-0 0 • 65/ .--
~
jGt; Addnill;
1
2
3
4
i -l lO~ I -7:47 .r-1 -. I ~ L
6 Ute of BulldJar. --~~ -/ ,.1 .... -,. .. -__ 17 P .... _. ""-~tc .. ,/ """cL...e.Jc. f..
1 1 o.cnl»ew-.r~c -_~i»fJ;t.C-~-~--~ i~-~ -T-· ·9~
s t OU.erWortc
~ 0
11
ti
A S!I'ARA'ft ELECTRICAL. PE.RM11' ' ~ _4!.Jij ~ ~ l5SVUBYTHIISTATEOPCOLORADO"f-t ~~ ._.::>/// ~
TB•fDIMll'HCOMESNIJU.ANDVOUHFWO'AKOilCONSTilllC'llON I -=-='?'-' .. I I I , • -•.• --I
A.IITROIUZID JS NOT COMIIENC&D WrnDM 110 D.\ VS.Oa.IF
CONSTaUCTIOI'C OR WORK IS SOSPEI'rDED OR ,uAI(l)ONJ:D FOR A
PEJUOD OF liD DAYS AT AI\"VTIIUAF'l'Ea WOitiC ISCONNEMQD.
I RUDY CI:Jd'lJIY THAT I RAW READ AND EXAMINED nm
APPWCAnOl'fAJQ)ICNOWTIIESo\IIGTOBIItTRIJEANDCORUCT. AU
PROYU10NSOfU1'r'SGOvatlfiNGT1rlSTWEOPWOUWILL11E
COMPLE'JED wrnnH WBEI'B:1R SPKJIIRD HElWM OR Nor. Till:
GIW'CTING OF A PEIIMIT DOD NOT l'USilM5 TO GM AtmiOIUTY
TO VlOLATt 0111. CANCEL~ bOVISIONS OP AA"Y OTDit Sf ATE Oil
~ LAW ~\!LA'IJffG# COIC.flialiCmON OR t1la. rsliJORMANC'& opd)~l't
AGJU:Ua!NT
Setba:ks:
PER.MlntON IS UR&8Y GM'a'&D 'tb TU-AWUGUCT .UOWNU. CONni.C10R A!'COIOR nn: Aatm"OP T8£C01miACTOil Oil OW!Ca TO CONSTIWCT
1111: S'DUicnJRI.U DETAU.UO!II I'L»iS A!G SPECJJIICATIONS SVBMrnEO TO A.>m R&VI&WIO IIY nmalilUJPIC: OUARni&NT.
11'1 CONSIIICRATION 0' 111£ ISSSUANCC OF THIS I'UIMlT, mi. SICNU. HEREBY AGREES Tt COMP1.Y WITil I•U. BIIU.PIJIIG COOts AND LAND USE
lUIGl!LATIONS ADOPnD .V GAJU1EU) COUlft'Y I'UliSUAJn' TO AUTRORin' GIVEN IN 31.zutl CKS AS AlG!fDtJ). TIB SIGffD l'\.'R111U AGAEE81BAT
lF TilE .UOVJ: S.UU ORIIOIAHCU ARE I'IOT 1UU Y CONr1U:D wrrB !If til& U'OATJON, IUCtlON,COI'ISTIWCTION, AND CU OP raE .UOVS D£5CRIIED
STJUIC'111RE, THE nRMJT MAY N HVOICED 8'Y Not1CJ: nOM T8£ COUNTY AMO TIL\TlB!l'f A1'ID TBER£ IT SIIAil. UCOME PM.L AND VOID.
TB& ISSl/AHCE or A PUtl\IT&UED L'PON PUNS. SPEC'UilC.l110NS AI'ID OTRI!ll DATA SUALL NOTrtliVII'o'I'TBE BIJILDINGOlPictAL PIOM TBUEAFBR
UQUIJUNC 'l'11E COitUCTJON OF mtaOI:S IN SAID PUNS. SPICU'ICATtOI'$ 4HD OTIIU "DATA OR nOM lRVIVI'TI1'IC IWIUIJNG OPI:RATIOI'I B£UitC
CARRIED ON TIIIJlBtll'(DEJl WilEN IN VIOLATION Of111!1 COOEOit 4l'IY0111EltOitDIHAI'fO:OR REGtiLAT10N 01'\'IIJSIVIUSilltTIOI'L
ntlf IIEV&W r:6 SliBMJTrEO PLAttS AND lriOJIJC\ TJONI MfD INSNCTIOHS COHl)UCTm 11IDEAFrD DOD MOT CIICS11101"£ AN ACCII'I'ANCE OF
A!Oo"Y USI'OI'ISlBILITJU oa UABUTIU BY CUFIED CDVNTY I'Oll IUOJII.S. OMISSIONS 011 DISCai!PINCUS.. 18& uti'OIQIIIU1'\' ma 11USE nDtS
AHD l'Mft.EMEN'tATJOI! DVRINC COKSTilUCT'IOl'( ltU1'S Sr&C'IJI!CLULY WlrH nu: ARncn:cr, DDIGNO, DtllLDI:R.7flj;D • COMMEinS AU
Rl'11:lfDD TO Ill CONSERV.\TJW .\NO DC SCIPI'OilTO.FTBE OwrfERS I'IT!lU:SI".
c ...........
l 11ERE8\' ACICHOWI.OJGE TXA.TI RAVE REA.D A."'D lJI'IDIIISTAMI TB£ ACJU!IIIWf'l' .UO~(IMJ1A1.).
Sp/ f!eutl /)/ tl:fr 7f!J:?-R #1' #?!¢/ $~~~
~:JJ-?.o'l rh · ~t•/olf ~ 1i~b65 -~f
~
-._.
--
~., '*•
I ~ev-ch~,eM.~ p. l
GARFIELD COUNTY BUILDING PEnnT APPLICATION
J•.-scr-,SutelOl,GimwoodSpri~~P.CO 11601 ~ 3 G3
Ptloac !170-945-UU I Fa.u !nt-)14..3'711 I IDrPtcdoa Uat: 97G.3~ -/ •
Permit No: q>/39 Parai/Sch4uNc::~C De:=" Z
3 57 -o o · o5j .--
!;
JGbAddr-.:
1 LotNa: ,
.+!
2
3
4
5 No. orfloon: z_
i
7 I DeKn"be Work: I orWortc
qe: c
~-~ ~~li1)Mfi:~
7-2~~05'
10 I o Driveway Penalt
11 V.Juadoa ofWerk: 5
ll Special Colldhloa.: 1,
.:J..,
A SII'ARAT& EUCTIUC.U. J'tRMIT ~ RI.'QIIIbtD ~~~ ~
ISSUf.DW'/TIIBSfATEOPCOU>P.ADO"I-/,(!,eA./o&4f ..:::>f/J ~ r , ~ _
TBISrDMITIII.COMESMIU.ANDVOIJ)JF'NORXOil('OMTIUJCTION ----I
411'71101UZ1D IS Har COMMEHCEIJ WrtBJN 110 DAYS. oa.IF
CO!Ul"RVCTlOI'I OR WORK IS SOSP£1'8£0 OR ABAI'IDONEO FOK A
PtlUOD Of JIG JIA YS AT AI'>"Y TIME AJITEJt WOJU( JS CONNENQD.
I 81Uft CEKJ'tJIY THAT I BAVI. READ AND EXAI\UrttD nns
APPLICA1101'1Al(DJ0(0WTHESMBTOB&'I1Uif;AMDCORJU!CT. AU
PROVIIIONIOFL.\WSGOVU!fiNGTKl!n'!EOPWOUWILl.BE I ~ .:L-«S.... :c:py: i
COMPUTED wrnuN WB£'I1IIR SPICIPIED KEUII'( OR NOT. 111£ -1 --
GRAJOI'DNG OF A I'EIIMJT 11018 NOT ftliSOIR TO GI'VIi AUTBORfTY
TO VJOJ.AD Oil CIJfCJ:L 111& IROVJSIONS OP ANY Ol'UER stATE Oil
~ LAW UGUU'QNG/COfii'I\R~ON OR 11lt; ~C&
OU!QSSTRIJCTJC)I'IJ II 1 i I I I 1 I I --I ---· -
4GJU%MI!HT
PnMihiON IS .RIUBY CP.A.'«m 1b TIUAri'UC41'1T ASO'WHU., COH'BAC10R MfDIOR 'niC AGESTOF TJI£<07ri11ACJ'OR Olt OW NEll TO CONSTlWCF
1111: SI'JUJCTIJU .U Dt:rAlUD ()!'( l'LANS Al'fD SPEOFICATIONS StJIMJn'r:OTO 4HD Rn'I&WD BYTB llill.DII'fC DUAitnUNT.
IN CONsmot.\110H OF 'l'Bt: ISSSUANC£ 0¥ ?JIIS PUMIT, t1lE SIGH'Pt. HERDY AGata Tt COiiVLY WIT1I I•'U. IJUU.»IJIIG CODES ~D LArfD U9£
UGVLATJONS ADOPTIIt In' GARJUU) COUI'fTY PURSUAH1' TO ..urtliORin' GIVEN IN 3UI.2tl CliS AS MIDCDED. 1'111: SIGHE1li'\IRJ1IU AGJlE£8111A?
lP 1B£ .UOVI SAID ORDeCAJitctS ARE lfOT fULl.\' COMPUD WlT8 l!f 11IE l.COATIOtC, &UC1101f. CO!'CSTRIICTJON, Al'fD VSE CW TBE AlOYS DESCIUIED
STitCJC'n/11& TIE ftiUIOT NAY KIIE\'OUD B\' !COT1Cr. fROM Til£ COUNTY AI'ID 11JAt''l8£rl A.ND 'l'BEAI: ITSBAI.I. NCOMEM/l.L AM) VOID.
TB&JSSUANQOfAPUMTMI£DWOHPI.ANS.SPECJIICATIOHIAI'ID0111ERDATA!IIIAJ.Lifari'UWHr'TIIX.UILDlNG0t'IIICIALnt0MTBUEAn'aR
UQUJ1UIIIC T1IE COitUCTJON OF GIAOIIS LH So\D» PUNS. SPI:curtCA'l10NS .unJ OTIID DATA OA JllOM PllE'/EI'I'm(G aun.DING Ol'DATJON IEII'IC
CAitlUID ON1111RIMmD WII'EN IN VIOLA liON Or 11IS CODE ORIIJf'/ OTBEit c:.DINANCCOR UGULA110N Olt,'IUSitlltiSDICI'10N.
1112 lti:YIItW M SUJI.'IQTIXV PlANS AND SPICJFICATIOI'II AND INSP&C'1'10NS COHOUcnD 'J"'DDI£AFJ'D J)()£S Mrr ~AN ACCUTAI'ICE OF
-'NY USI'OI'ISUIO.n'JES OR UABtn11S In' GUFIDD COUNTY lOll EIUtOitS, OMJSSIONS OR DISOiriNCUS. 111& USI'OI'IBIBIUTY R:IR tBI!IJ: l"l'EMS
AND lMPLIMENTA'nOPI DllRIHG COICSniJC1101'1 ltU1'S Sl'llCIJIIO.U.LY wrru TU ARTIC'I'ECT, DUIGND. lllllLDtlt,~D • COMMII'ITS AR£
INl'IMIOTOUCONSEilV.TtVEANDI!fSOPPORTOPT81!0Wl'I£RSwri:RIST.
CartoaOU
1 BEREBY ACKNOWLIIIGI TJIAT IRA \IE READ A."'D IINDIRST AffD Til£ ACIUIIM&IIT ABOVE(Jl'lliiAL):
8pl t!BH/f" IJI t/5/ ;r:; ;J:l-R ~ ~~/
~sJ..?.o'i ~· -sl•/otf ~ 1'%bs"
J
The following items are required by Garfield County for a final inspection:
1. A final Electrical Inspection from the Colorado State Electrical Inspector;
2. Pennanent address assigned by Garfield County Building Department posted where readily
visible from access road;
3. A finished roof, a lockable house, complete exterior siding, exterior doors and windows
installed, a complete kitchen with cabinets, a sink with hot & cold running water, non-absorbent
kitchen floor coverings, counter tops and finished walls, ready for stove and refrigerator, all
necessary plumbing;
4 . A complete bathroom, with washbowl, tub or shower, toilet stool, hot and cold running water,
non-absorbent floors and walls finished and a privacy door;
5. All steps outside or inside over three (3) steps must have handrails, guard rails on balconies or
decks over 30" high constructed to alll997 UBC requirements;
6. Outside grading done to where water will detour away from the building;
7. Exceptions to the outside steps, decks and grading may be made upon the demonstration of
extenuating circumstances, i.e. weather, but a Certificate of Occupancy will not be issued until
all the required items are completed and a final inspection made;
8. A final inspection sign off by the Garfield County Road & Bridge Department for driveway
installation, where applicable; as well as any final sign off by the Fire District, where applicable.
A CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL ALL THE
ABOVE ITEMS HAVE BEEN COMPLETED.
****CANNOT OCCUPY OR USE DWELLING UNTIL A CERTIFICATE OF OCCUPANCY
(C.O .) IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE
CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING
PREMISES UNTIL ABOVE CONDITIONS ARE MET.
I understand and agree to abide by the above conditions for occupancy, ~e and the issuance of a
Certificate of Occupancy for the dwelling under building pennit # 9/81 .
tutti-;Wt(l 11 i);;,ID tf
Signature Date
Bpcont03 /2004
~
VALUATION/FEE DETERMINATION
Applicant.....,..~~..!:....!:":....J-...
Address.-:JL..!Io.,j:.....__~~
Date
Subdivision~y Sl.(lx/. S ~ Lot/Block Lo+ 0 1onct~~~~"~S Contractor Ow,....,er
l;x~pfio 111
Total Square Feet l'<;?Jh '1-~9 ::
Valuation
Basement:
Unfinished
Conversion of Unfinished to Finished
Plan Check Fee for Conversion
Valuation
Garage:
Valuation 7 !t '( I b
Crawl Space:
Valuation
Decks/Patios:
Covered
Valuation
Open
Valuation 501
Total Valuation
'f {7,..
g5 D()~
/
14 II~
~oq~
~~ ffo8
~"0~ P~ 7-z~.fJ~
VALUATION/FEE DETERMINATION
Applicant~
Address ...-DE( ().K!El
Date 1 ~2&,-o,-
Subdivision
Lot/Block
Contractor
Total Square Feet 208 8 'v 71 . b -f .: /5~ Cf'3/ !.1
Valuation I
Basement:
Unfinished
Conversion of Unfinished to Finished
Plan Check Fee for Conversion
Valuation
Garage:
Valuation 44£ 'I { g
Crawl Space:
Valuation
Decks/Patios:
Covered
Valuation
Open
Valuation /p .5 ~ "i-/'L
Total Valuation
'/J'f;uJ ~ l=i.tj
P--A1o '' ''
:: 8ofD4
-7S7~ -
J7J, Sta7 JO
z~~~7
I~ '15"~ 13
~ 09. 84 BAt,~~
Plans to be Included for a Building Permit, must be on drafting paper at least
18'"x24" and drawn to scale.
Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides
with decks, balcony, steps, hand rails and guard rails, windows and doors, including the
finish grade line. A section showing in detail, from the bottom of the footing to the top of the
roof, including re-bar, anchor bolts, pressure treated plates, floor joists, wall studs and
spacing, insulation, sheeting, house-rap, (which is required), siding or any approved
building material.
A window schedule. A door schedule.
A floor framing plan, a roof framing plan, roof must be designed to withstand a 40 pound
per square foot up to 7,000 feet in elevation, an 80 M.P.H. windshear, wind exposure B,
windload of 15 pounds per square foot, and a 36 inch frost depth.
All sheets to be identified by number and indexed. All of the above requirements must be
met or your plans will be retumed.
All plans submitted must be incompliance with the 1997 UBC, UMC and 1997 UPC.
1. Is a site plan included that identifies the location of the proposed structure or
addition and distances to the property lines from each comer of the proposed
structure(s) prepared by a licensed surveyor and has the surveyors signature and
professional stamp on the drawing? Properties with slopes of 30% or greater must
be shown on the site plan. NOTe: 106.3.1 (7~Any site plan for the placement of
any portion of a structure within 50 ft. of a pro . rty line and not within a previously
surveyed building envelope on a subdivisio final plat shall be prepared by a
licensed surveyor and have the .surveyors signature and professional stamp on the
drawing. Any structure to be built within a building envelope of a lot shown on a
recorded subdivision plat, shall include a copy of the building envelope as it is
shown~e final plat with the proposed structure located within the envelope.
Yes._~~--
2. Does the site plan also include any other buildings on the property, setback
easements and utility easements? Please refer to Section 5.05.03 in the Garfield
County Zoning Resolution if the property you are applying for a building permit on is
located 09-a comer lot. Special setbacks do apply.
Yes ___ ./ __ Alo ~tJt Lv//1/~s-UTil-ITY E4S6A.fC..v;-.J CJfti~-)..-
3. Does the site plan include when applicable the location of the I.S.D.S. (Individual
2
4.
1: ...
6.
7.
8.
9.
10.
11.
12.
13.
Sewage Disposal System) and the distances to the property lines, wells (on subject
property and adjacent properties), streams or water courses?
Yes_ ~
Does the site plan indicate the location and direction of the County or private road
accessing)he property?
Yes_V::..,_ __ _
Do the plans include a foundation plan indicating the size , location and spacing of
all reinforcing steel in accordance with the uniform building code or per stamped
engineered design?
Yes v
Do the plans indicate the location and size of ventilation openings for under floor
crawl spaces and the clearances required between wood and earth?
Yes~ __ v
Do the plans indicate the size and location of ventilation openings for the attic, roof
joist spaces's and soffits?
Yes ___ ~
Do the plans include design loads as required by Garfield County for roof snow
loads, (a minimum of 40 pounds per square foot up to & including 7,000 feet above
sea level), floor loads and wind loads?
Yes ,/ •
Does the plan include a building section drawing indicating foundation, wall, floor,
and roof construction?
Yes V::: ) 1 Does the building section drawing include s1ze nd spac1ng offlooqo1sts, wall studs,
ceiling joists, roof rafters or joists or trusses?
Yes_ -~ ~.
Does the building section drawing or other detail include the method of positive
connection of all columns and beams?
Yes. _____________ _
Does the plan indicate the height of the building or proposed addition from the
.highest point of the building or addition measured at mid span between the ridge
and the eave down to existing (undisturbed) grade contours?
Yes v
Does the plan include any stove or zero clearance fireplace planned for installation
3
i
including make and model and Colorado Phase II certifications or phase II EPA
certification?
Yes. _____ _ No ../'
14 . Does the plan include a masonry fireplace including a fireplace section indicating
design to comply with the Uniform Building Code Chapter 37?
Yes No ~
1 '5. Does the plan include a window schedule or other verification that egress/rescue
windows from sleeping rooms and/or basements comply with the requirements of
~:s~nifo2ilding Code? No ______ _
16. Does the plan include a window schedule or other verification that windows provide
natural light and ventilation for all habitable rooms?
Yes C No. ______ _
17. Do the plans indicate the location of glazing subject to human impact such as glass
doors, glazing immediately adjacent to such doors; glazing adjacent to any surface
normally used as a walking surface; sliding glass doors; fixed glass panels; shower
doors an~ enclosures and specify safety glazing for these areas?
Yes ~ No _______ ..... ______ ____
18. Is the location of all natural and liquid petroleum gas furnaces, boilers and water
heaters indicated on the plan?
Yes . ~ No~-----------
19. Do you understand that if you are building on a parcel of land created by the
exemption process or the subdivij"on process, are building plans in compiancewith
all plat note..§ and/or covenants? \
Yes y/ No._______ f
.
20. Do you understand that if you 'belong to a homeowners association, it is your
responsibility to obtain written permission from the association, if required by that
association, prior to submitting an application for a building permit? If you do not
have written permission from the association, do you understand that the plan check
fee will not be refunded should the architectural committee deny or reject your
building plat}J?
Yes ~ No __________________ ___
21 . Will this be the only residential structure on the parcel?
Yes . _ _ ____ No. _ _.v'~----If no-
Explain: FcJ r e ~<= P~ ,_N'.s 1../u ~ , '\/ t:t '"-u o .; ..:J oo o tLl .D 1~:~~"' ,.,, c:r
/frr~c,~ 7-o c c.J/Z.eS.vl A ~ PL .-f-r.ovC.O q.~ 4-Crt£/Dt.N~cc:.,,Jq-
4
22 .
23.
2-!.
25.
26.
27 .
28.
29.
30.
31 .
Have two (2) complete sets of construction drawings been submitted with the
application?
Yes . L
Do you understand that the minimum dimensions a home can be on a lot is
20ft.wide and 20ft. long?
Yes u. / No. ____ _
Have you designed or had this plan designed while considering building and other
construction code requirements?
Yes 1/ No. _____ _
Do your plans comply with all zoning rules and regulations in the County related to
your properties zone district?
Yes ~ No ·------
Does the plan accurately indicate what you intend to construct and what will receive
a final inspection by the Garfield County Building Department?
Yes £ No. _____ _
Do you understand that approval for design and/or construction changes are
required prior to the application of these changes?
Yes ~ No. ______ _
Do you understand that the Building Department will collect a "Plan Review'' fee
from you at the time of application submittal and that you will be required to pay the
"Permit Fee" as well as any "Road Impact" or "Septic System" fees required, at the
time you pick up your building permit?
Yes v No ~
Are you aware that twenty-four (24) hour notice Is required for all Inspections?
Inspections will be made froiJI Battlement Mesa to West Glenwood In the
mornings and from Glenwood Springs to Carbondale In the afternoons. All
Inspections must be called In by 3:30 p.m. the day before. Failure to give
twenty-four (24) hour notice for Inspections will delay your inspection one (1)
day. Inspections are to be called In to 384-5003.
Yes v No _____ _
Are you aware that requesting inspections on work that is not ready or not
accesslbJe..will result in a $47.00 re-inpsection fee?
Yes ~ No·-------
Are you aware that you are required to call for all inspections required under the
Unifonn Building Code including approval on a final inspection prior to receiving a
5
Certificate of Occupancy and occupancy of the building?
Yes ~ _ No _________ __
32. Are you aware that the Permit Application must be signed by the Owner or a written
authority be given for an Agent and that the party responsible for the project must
comply with the Uniform Building Code?
Yes _ -./ No, _____ _
33. Are you aware that prior to submittal of a building permit application you are
required to show proof of a driveway access perm it or obtain a statement from the
Garfield County Road & Bridge Department stating one is not necessary? You can
contact the Road & Bridge Department at 625-8601.
Yes V: No, ______ _
34. Do you understand that you will be required to hire a State of Colorado Licensed
Electrician and Plumber to perfonn installations and hookups, unless you as the
homeowner are performing the work? The license number of the person performing
the work will be required at time of applicable inspection.
Yes V::::: No, ______ _
35. Are you aware, that on the front of the Building Permit Application you will need to
fill in the Parcel/Schedule Number for the lot you are applying forth is permit on prior
to submittal of a building permit application? Your attention in this Is appreciated.
Yes v<: No ________ -______ _
I hereby acknowledge that I have read, understand and answered these
questions to the best of my ability.
~A-?§\ )
Signature of Owner Date
• ~ /A ;1-.... ~~A-)
Phone : 2~~-23 7-l i!-89 (days);~J5(fE...!uve:rsrrr"'/V 1.s 10 ~' _ _ 1 ~c..o (b. ,z ~tG Slo zo 47 (eveRiAgs) c_G.t-'-p~e (o¥~o. r foAJ '*' 1 JJ t:;¥f
Project j,
Name: !(; h ~ Y cfM .4-t:£~ !J? tv#/. t.,/ N<i •
Project
Address: eu.e-.4 ~,/Jt?=t' 5u6DI v't ~r()N .. Se~ I/7T;t-elfStJ ~ct<4Tr OtV #@
Notes:
If you have answered "No" on any of the questions, you may be required to provide this
6
PLAN REVIEW CHECKLIST
Applicant H IL 'Jh Date $:27 .£)*
Building
~Engineered Foundation
/oriveway Permit
_Surveyed Site Plan?
./Septic Permit and Setbacks ~ .
~deffopography 30%
~ch Resident i al Plan Review List
~mum Application Questionnaire
~bdivision Plat Notes 2 ~~.)
~Fire Department Review
./"' .. __ Valuation Determmatlon/Fees
~ Line Plans/Stamps/Sticker
~ach Conditions
~lication Signed
~ Reviewer To Sign Application
__,.,..-~---
Parcel/Schedule No.
lJ..J_A40# Snowload Letter-Manf. Hms.
GENERAL NOTES:
Planning/Zoning
Property Line Setbacks
30ft Stream Setbacks
Flood Plain
Building Height
___ Zoning Sign-off
__ Road Impact Fees
HOA/DRC Approval
__ Gradeffopography 40%
Planning Issues
Subdivision Plat Notes
Sn: ~ ;~'rD
~5j)!UtS.W>< ~f
.-{'-lc~.
Invoice Number:
Bill To:
'-'
q_q_~[!.eld 9ounty
Roild and Bridge Oep.utmenl
902l'aughenbilugh Blvd., Ste 305
IUfle, CO 81650
l'hone-(970)6~601 fax-(970)625-8627
13 Invoice Date:
George Kilby
,CO
1/17/01
Driveway Permit Number: 17
$15.00 per Driveway Permit.
Driveway Permit Fee: $15.00
----·--------------------------
Total Due: $15.00
Thank You!
11AI ID
~(1/ . (17/o;
EXHIBIT B pgl
.
Garfield Cottn
Application for Driveway Permit
Application Date: 1117101
Termination .Date:419/0l
District: 1
Permit Number:17
County Road Number: 100
Sub-Co11tractor:
Permitee: George Kilby
Inspector:Kenny Gardner
George Kilby hereby requests permission and authority from the Board of County Commissioners to construct a
driveway approach (es) on the right-of-way off of County Road 100, adjacent to Applicant's property located on the
north side of road for the purpose of obtaining access to property. -
Applicant submits herewith for the consideration and approval of the Board of County Commissioners, a sketch of the
proposed installation showing all the necessary specification detail including:
II>
1. Frontage of lot along road.
2. Distance from centerline of road to property line.
3. Number of driveways requested
4. Width of proposed driveways and angle of approach.
5. Distance from driveway to road intersection, if any.
6. Size and shape of area separating driveways if more than one approach.
7. Setback distance ofbuilding(s) and other structure improvements.
8. No unloading of equipment on county road, any damage caused to county road will be repaired at subdivision
expense.
9. Responsible for two years from the date of completion.
General Provisions
1) The applicant represents all parties in interest, and affirms that tne driveway approach(es) is to be constructed by
him for the bona fide purpose of securing access to his property and not for the purpose of doing business or
servicing vehicles on the road right of way .
2) The applicant shaU furnish all labor and materials , perform all work, and pay all costs in connection with the
construction of the driveway(s). All work shall be completed within thirty (30) days of the pennit date.
3) The type of construction shall be as designated and/or approved by the Board of County Commissioners or their
representive, and all materials used shall be of satisfactory quality and subject to inspection and approval of the
Board of County Commissioners or their representive.
4) The traveling public shall be protected during the installation with proper warning signs and signals and the Board
of County Commissioners and their duly appointed agents and employee shall be held hannless against any action
for personal injury or property damage sustained by any reason of the exercise of the Permit.
5) The Applicant shall assume responsibility for the removal or clearance of snow, ice, or sleet upon any portion of
the driveway approach(es) even though deposited on the driveway(s) in the course of the County snow removal
operations.
EXHIBIT B pg2
~
..
Specifications
1. A driveway approach is understood to be that portion of the county road right-of way between the pavement edge
and the property line that is designed and used for the interchange of traffic between the roadway and abutting
property.
2. At any intersection, a driveway shallqe restricted for a sufficient distance from the intersection to preserve the
normal and safe movement of traffic. (It is recommended for rural residence entrances that a minimum
intersection clearance of 50 feet be provided and for rural commercial entrances a minimum of 100 feet be
provided .)
3. All et.trances and exits shall be so located and constructed that vehicles approaching or using them will be able to
obtam adequate sight distance in both directions along the county road in order to maneuver safely and without
interfering with county road traffic.
4 . The Applicant shall not be pemUtted to erect any sign or display material, either fixed or movable, on or
extending over any portion of the county road right-of-way. _
5. Generally, no more than one approach shall be allowed any parcel or property the frontage of which is less than
one hundred (100) feet. Additional entrances or exits for parcels having a frontage in excess of one hundred 100)
feet shall be permitted only after showing of actual conven ience and necessity .
6. All driveways shall be so located that the flared portion adjacent to the traveled way will not encroach upon
adjoining property.
7. No commercial driveway shall have a width greater than thirty (30) feet measured at right angles to the centerline
of the driveway except as increased by permissible radii. No noncommercial driveway shaU have a width greater
than twenty (20) feet measured at right angles to the centerline of the driveway, except as increased by
permissible radii.
8. The axis of an approach to the road may be at a right angle to the centerline of the county road and of any angle
between ninety (90) degrees and sixty (60) degrees but shall not be less than sixty (60) degrees. Adjustment will
be made according to the type of traffic to be served and other physical conditions .
\
9. The construction of parking or servicing areas on the county road right-of-way is specifically prohibited.
Commerci al establishments for customer vehicles should provide off-the-road parking facilities .
10. The grade of entrance and exit shal1 slope downward and away from the road surface at the same rate as the
nonnal shoulder slope and for a distance equal to the width of the shoulder but in no case less than twenty (20)
feet from the pavement edge. Approach grades are restricted to not more than ten percent (I 0%).
11. All driveways and approaches shal1 be so constructed that they shall not interfere with the drainage system of the
street or county road . The Applicant will be required to provide, at his own expense, drainage structures at
entrances and exits, which will become an integral part ofthe existing drainage system. The Board of County
Commissioners or their representative, prior to installation, must approve the dimensions of all drainage
structures.
Note: This permit shall be made available at the site where and when work is being done. A work sketch or
dr.twing of the propost..>d driveway(s) must accompany application. No permit will be issued without drawing,
blueprint, or sketch.
EXHIBIT B pg3
Special Provisions for Excavation ofRoad Surface and Installation
I) Any oversized material, (larger than I 0 inches in diameter), that is not utilized in backfill will be hauled off by
permitee. Further, any frozen material will be removed from site by permittee.
2) When a paved or chipped surface is cut, it is to be replaced with a minimum three-inch (3") hot mix asphalt patch.
Temporary patch with cold mix asphalt would be allowed, which would be replaced with hot mix asphalt when
the weather or availability of materials aJJow the work to be completed. An asphalt or chipped surface cut would
require the road to be straight cut and squared by means of a pavement cutter or saw. A chipped surface cut will
requir~ a seal coat of the patch, which will be full width or half width of roadway when trenches run with the
road. !'or trenches across the road, the edges of the seal coat will overlap the existing edge. All seal coats will
overlap edges by a two of the roadway in the vicinity of the excavation. Asphalt bot mix or cold patches will be
completed in a maximum of five (5) working Days. Weather pennitting.
3) When possible all installations should avoid the top edge of a fill slope.
4) Installations in drainages subject to flash flooding will have a minimum bury of 4 feet deeper than normal flow
line at nearest abutment, wing walL or culvert.
5) Installations at culvert crossings will be buried beneath the culvert with a minimum separation of 18 inches
between installation and the bottom of the culvert.
6) Open trenches adjacent to the traveled roadway shall be backfilled daily to within 100 feet of the working area of
the trench, and shall be barricaded with warning devices after dark. A 3 foot high orange plastic fence will be
installed daily to keep livestock out of the open trench after hours .
7) In areas being disturbed where vegetation is established, reseeding with a mixture either by broadcasting, drilling
and mulching with seed mixtures suitable to the climatic conditions or existing vegetation wiii be performed. Use
only certified weed-free seed Noxious weed control will be ongoing along with revegetation.
8) The pennittee should check the R-0-W of surrounding landowners to see if other permits are required, i.e., BLM,
Forest Service.
r Garfield County Road and Bridge
k!~A
EXIIIBIT B pg4
. .
6) In the event it becomes necessary to remove any right-of-way fence, the posts on either side of the entrance shall
~e surely braced before the fence is cut to prevent any slacking of the remaining fence, and all posts and wire
removed shaH be turned over to the District Road Supervisor of the Board of County Commissioners.
7) No revisions or additions shall be made to the driveway(s) or its appW1enances on the right-of-way without written
permiss ion of the Board of County Commissioners.
8) Provisions and specifications outlined herein shall apply on all roads under the judsdiction of the Board of County
Commissioners of Garfield County, Colorado, and the Specificatioqs, set forth on the attached hereof and
incorporated herein as conditions hereof.
"' Special Conditions:
2. stop sign, 15"culvert
3 . subdivision entrance shall be asphalt 3" thick from cr 100 back to property line.
4. the approach will enter at a 90degree angle to CR I 00
5. any new fences, rocks, scrubs,dirst, or other decorative items shall be on property of subdivision not on county
right of way
6. any signs overhead or otherwise shall be on subdivision property, not on county right of way and shall not
obstruct line of sight.
7. 3'4" roadbase shall be laid and used until weather is wann enough to pennit asphnlting, so as not to track mud on
county road
8. Asphalt or concrete wiU be placed as soon as weather pennits
9. Driveway wiU be subject to fmal inspection when completed
...,. 10. Responsible for two years from the date of completion
II. Must call Jake Mall at 876-2348 for final inspection.
In signing this application and upon receiving authorization and permission to install the driveway approach (es)
described herein the Applicant signifies that he has read, understands and accepts the foregoing provisions and conditions
and agrees to construct the driveway(s) in accordance with the accompanying specification plan reviewed and approved
b-? t~ "'ard of County Commissioners.
Signed: \fL~e~ 7
Address:
Telephone Number:
----------------------------------------------------
Permit granted 1/17/01. subject to the provisions, specifications and conditions stipulated herein.
For Board of County Commissioners' of Garfield County, Colorado:
Repr esen tative of Garfield County Road and Bridge Signature
EX III BIT B pg5
. ~
1:11/18/26131 68: -1~ 97El9<156!;)S9 __ _
Subdivis ion Driveway Permit
George R. Kilby
Mayfly Bend Ranch Subdivision
(970) 94 7-9733 (Ivan Perrin residence)
(256) 237-7289 (Kilby Home phone)
(256) 310-2027 (cell)
North side of Cr.lOO,
Stop Sign
15" Culvert
Subdivision entrance shall be asphalt 3" thick from Cr.l 00 back to
Property line.
The approach will enter at a 90 degree angle to Cr. 100 .
Any new fences, rocks, scrubs, dit1, or other decorative items shall
be on property of subdivision not on county right-of-way.
Any signs overhead or otherwise shall be on subdivision property,
not on county right-of-way, and shall not obstruct line of sight.
I
%, roadbase shall be laid and used until weather is warm enough
to pem1it asphalting, so as not to track mud on county ro a d.
No unloading of equipment on county road,any damage caused to
county road will be repaired at subdivision expense.
¥,~~~fit c~,.J~;r
PAGE 61
EXHIBIT B pg6
I
• " • J
~ech
HEPWORTH-PAWLAK GEOTECHNICAL
February 16, 2004
George R. Kilby
505 Sandy Lane
Anniston, AI. 36207
Hep\\'orth·Paw lak Georechnic;~[, Inc.
5020 County Road 154
Gl~n w ood Spr ings, Color:~do 81601
Phone: 970 -945-7988
Fax: 970-945-8 45-f
email: hpgeo@h pgeorech.com
Job No. 104 156
Subject: Observation of Profile Pit, Proposed ISDS System, Lot 3, Day
Subdivision, Northwest of Mayfly Bend Subdivision, Garfield County,
Colorado
Dear Mr. Kilby:
As requested, a representative of Hepworth-Pawlak Geotechnical, Inc. observed the
profile pit at the subject site on February 16, 2004. The findings of our observations
are presented in this report. The services were performed in accordance with our
agreement for geotechnical engineering services to you, dated February 16, 2004.
The site is located in the bottom of the Roaring Fork River Valley, east of Carbondale
and north of County Road 100, northwest of Mayfly Bend Subdivision and south of the
Roaring Fork River. Vegetation consists of cottonwood trees and brush with a ground
cover of grass and weeds. There was about 6 inches of snow cover at the time of our
~
site visit. The ground surface is relatively flat with a slight slope down to the north.
The Oxford irrigation ditch crosses through the site from east to west about 40 feet
north of the Profile Pit. The proposed building site is about 120 feet to the east of the
Profile Pit.
A Profile Pit had been excavated at the location shown on Figure 1. The subsoils
exposed in the pit consisted of 1 foot of topsoil overlying slightly silty to silty, fine to
medium sand to the bottom pit depth of 7 feet. Free water was encountered at about 61h
feet and the upper soils were moist.
Parker 303~841~7119 • ColoradoSprings 719~633~5562 ° Silverthorne 970A68~1989
I \1 • I
, George R. Kilby
February 16, 2004
Page 2
If you have any questions or need further assistance, please call our office.
Sincerely,
HEPWORTH-PAWLAK GEOTCHNICAL, INC.
Louis E. Eller
Reviewed by:
LEE/ksw
attachments Figure 1 -Location of Profile Pit
cc: Sopris Engineering -Attn: Paul Rutledge
Job No. 104 156
~tech
4 t• I ,I
APPRQ}(JMA TE SCALE
1" = 30'
PROFILE
PIT.
__ _,
--I ----\ lswu;NG \
I ENVELOPE \
I \
\
\
\
\ . \
\
PROPOSED \
RESIDENCE \
I
I
I
I
\
\
\
\
\
I
I
:r:
~
B
a a::
~
0
104 156 HEPWORTH-PAWLAK
GEOTECHNICAL, INC. LOCATION OF PROFILE PIT Figure 1
COUNTY OF GARFIELD .. BUILDING PERMIT
CORRECTI ON N O TICE
1 08 8th St., Suite 401 Glenwood Springs, Colorado
Phone (970) 945-8212
Job located at .3~5 lf?~r:z• ~
Permit No. 91 3 £'
I have this day inspected this structure and these
premises and found the following corrections needed:
J)~~~~~a..
~~~~
~~.
~)~~-*~~·~
3)/~ ~a.dp~~
nsf/J1E &'/'I -rttL 1'17t:t
'i) ~ ~1""~~-z ~ ..<;;,. .u ~~
~)
You are hereby notified that the above correction must be inspected
before covering.
When corrections have been made, call for inspection at 970-384-5003 .
Date 9-G-o6 20 ~.-----
Building Inspector ~ ~~
Phone (970) 945·8212
'.
COUNTY OF GARFIELD -BUILDING DEPARTMENT
CORRECTION NOTICE
108 8th St., Suite 201 Glenwood Springs, Colorado
Phone(970)945-8212
Job located at 3¥s-~ £..
Permit No. 9139 _
I have this day inspected this structure and these
premises and found the following corrections needed:
t)~p~~
-J~~.$V.r~
J)~~~~
~}~~~
s) ~ F~ ¢'1,//~ ,; b)~~ ~~_u_bc-U(."ff
~~)
7)~~~
~r"~ ~adiJAk~ djU
,o)Md~~~ ,,) ~ r~--~a,,,r
You are hereby notified that the above correction must be inspected
before covering.
When correction(s) have been made, call for inspection at 970-384-5003.
Date 6 -IS. o / 20 =--=--
Building Inspector :/?ib~
Phone (970) 945-8212
. L ~
THE ELEVATOR COMPANY TM
I MOUNTAIN ELEVATOR
FINAL ACCEPTANCE OF ELEVATOR
We have examined the elevator furnished and completed by The Elevator Company at the
JobNamc K.tt...~"· Q£~ Locatedat MA'< 1-LY l3f~l) ~lliJCH !.Ai~lf•!)/'t~.J 1 (0 .
The elevator Equipment, Hoistway entrances & Cab (enclosure) have been thoroughly inspected and
found satisfactory. The elevator is in accordance with our contract and we hereby accept it.
Contract with: ~e.ou,E t,L~\ By: ________ _
(Contractor or Owner)
Equipment:
(Print Name of Person Accepting)
Manufacturer: lH ~ ~~VA Toe Ct>. Type: Rf::vOL-..U "TI o rJ
Elevator Information
The below i~rmation has been reviewed with the undersigned by the Installation Technician
; C~IJ' k::.... ::r1:;-r.c (l_<;ol\) • Please initial each item when complete.
1. Verified elevator/equipment is equipped and installed as ordered.~
2. Contracto!{~ner has been informed as to the proper operation of equipment, controls and safety
features . fir" ~
3. Verified that the phone line is operational "'F:>I !!!
Verified that the phone line is not operational and the customer acknowledges that fact. The
Customer understands and has acknowledged with signature below that The Elevator Company
must be notified when the phone line is operational and that all operation of elevator/equipment is
at users own risk until this notification is received.--=,....;=~
4. Assisted the contractor/owner on an orientation ride. ·~
5. Explained the warranty period and need for maintenance (below). ~
6. Explained hours of operation and emergency contact information (below).~ --
Service and Contact Information
The New Installation Warranty/Service will begin immediately and will continue for _b. Months. C!2(;f"'\ ~ ...
-r"vSPErr,c.JN
Our Normal Business Hours are 8:00am to 5:00pm Monday -Friday. For Emergency service or questions
reganling this installation, user may calll-866-553-842124 hours a day 7 days a week.
'
Acceptance and Customer Responsibilitv
This above referenced job bas been completed per contractual requirements. The undersigned bas
inspected the Elevator equipment and agrees to accept AJI in its present condition. We recommend the
equipment be protected from damage during the final stages of the project completion. Please be aware
any damage to the equipment after this form bas been signed will be the responsibility of building owner
or his agents. The Elevator warranty will commence as of the date of this acceptance form. Please review
your contract for the apP.licable warranty term.
/
Accepted By: _______________ ......;.._
(Signature of Person Accepting)
~·;..., /_
Date: -V ~ -~7
7800 Hwy 82, Suite #206 • Glenwood Springs, Colorado 81601 • 970-945-8421 Phone • 970-945-8462 Fax
ulu (l) Q.) (J)U1 A TRACT OF LAND SlnJA TED IN LUI::. o, ' "'~.. • "'• ~--.. -. . .
88 WEST OF THE SIXTH P.M., GARFIE'LD COUNTY, COLORADO AND EE 'NG A POR TJ -. · 'f -. ·
TRACTS OF' LAND AS DESCRIBED IN DOCUMENTS RECORDED UNDER RECEPTI ON •J 1 \;;<i .• '--
380981 AND 478497 OF THE RECORDS OF SAID COUNTY, SAID TRACT C'F :._;'\r ::.=._r ·, •· • 1
PARTICULARLY DESCRIBED AS FOLLOWS;
BEGINNING AT A POINT FROM WHICH THE SOUTHWEST CORNER OF F-AR Sf._ -,
LAND DESCRIBED IN SAID DOCUMENT RECORDED UNDER RECEPTION #3 72'Y'·" .._~.., ..
·---------
':fiver
A DISTANCE OF 482.49 FEET, THEN N.05'22'00"W. A DISTANCE OF 140./8 tEE ~· ~ ·-
N.30'51'00"W. A DISTANCE OF 95.91 FEET; THEN N.45'27'53"E. A DISTA'f'".E 0• -r
FEET TO THE THREAD OF THE ROARING FORK RIVER; THEN ALONG SA 'C i'.:'.'E r... -
COURSES:
---.......... -.... ........
--........ ______ --.
------....... ~--------
1) S.5217'07"E. A DISTANCE OF 133.38 FEET;
2) S.65'58'13•E. A DISTANCE OF 214.05 FEET;
3) S.8117'54•E. A DISTANCE OF 184.09 FEET TO THE EAST UHE OF SAIS 1.... 1 ~
DEPARTING SAID RIVER AND ALONG THE EAST LINE OF SAID LOT 18 5.0 0 '~3·::::·::. '.
OF 251.82 FEET: THEN DEPARTING SAID EAST LINE N.68'31'45"W. A OI STA W:.£ ::-·""
THEN S.13'26'4a•w. A DISTANCE OF 76.62 FEET; THEN S.22'0E'54"W. A :..!~r.;·
FEET TO 1HE SOU1HERLY BOUNDARY OF THAT TRACT OF LA"'D AS DESC.k'Fi!;.(..
RECORDED UNDER RECEPTION lf478497; THEN ALONG SAID SOUrnER!....'i !:..., •I
COURSES:
1) S.B9'24'57"W. A DISTANCE OF 287.67 FEET;
2) S.89'42'00"W. A DISTANCE OF 374.37 FEET TO THE POINT OF B£GIN I~ll'"r'
SAID TRACT OF LAND CONTAINS 7.47 ACRES AS DESCRIBED.
----1 00' Witness Cor. z
1\)lg (.11' ~~
01 -No -~
==
NOTES:
1) BEARINGS AS SHOWN HEREON ARE BASED UPON A BEARING OF ~L -· :·
UNE OF LOT 18, SEC. 35, T. 7 S., R. 88 W. OF THE 6TH P.M. MON ul.!EW.LI. "':l .
IN 11-IE FIELD AS INDICA TEO HEREON.
2) 11-IIS PROPERTY IS SUBJECT TO EASEMENTS AND RIGHTS OF WA ( J r-t.•, -.
REQUEST NO EASEMENTS HAVE BEEN SHOWN OTHER THAN THE NEW 25.C" r -:
ACCESS EASEMENT BEING CREA TEO BY VIR1UE OF THIS DOCUMEIH.
3) ALL LOTS SHALL REQUIRE AND ENGINEERED !.S.O.S. SYSTEM AT ,..ri!:.. m.lr • · ~
PERMIT SUBMITIAL IN ADDITlON, ANY REPAIRED OR REPLACED !.S.O.S. !.>HA'_!.. r:F ~ 1 ,
A REGISTERED PROFESSIONAL ENGINEER.
4) All LOTS INCLUDE PORTIONS OF THE REGULATED 100 YEAR FL.C0C r-'-A'r
FORK RIVER. ANY ENCROACHMENT IN THE 100 YEAR FLOOD PLAIN WI!.... .. L,cc.· .~f. ..1
PERMIT FROM GARFIELD COUNTY.
5) TI·US PROPERTY IS SUBJECT TO A MEMORANDUM OF UNDERSTA ND!~ • ..; A'1 ..,;
~-~-~-AT PAGE UNDER REC::PTI ON # _ ----
OF GARFIELD COUNTY, COLORADO. nilS AGREEMENT IS 811\DING ON ALL f'JfJR E , .. h· •·
PROPERTY AND CONTAINS SPECIFIC CONDITIONS REGULATING THE USE OF Trlt. F .L:, .E .
6) ANY RELOCATION OF THE BUILDING ENVELOPES WILL REQUIRE COMP t.J A·J:t 7"r ";t ,,
COUNTY fLOODPLAIN REGULATIONS.
7} AL lliOUGH 1HE BUILDING ENVELOPES SHOWN HEREON ARE AB OVE TI-lE E-f '.t. -,-r
YEAR fLOODPLAIN OF lliE ROARING FORK RIVER, 1HE PARCELS AND THE t:t '1L.::1t-. ·, :..,::
ENTIRELY FREE FROM fLOOD HAZARDS.
8) iHE ELEVATIONS SRtJWt.i ll!:Ri;Ob' AR~ @A~~D UPOtJ m'"ELEVATiCr! (I f fl ~.:. L -'
U.S.G.S. S.M. 0-156 WHICH IS SHOWN AS R.M . #22 ON THE FLOOD INS''RM !.:;f. l~.c~
-GARFIELD COUNTY, COLORADO, ON COMMUNITY PANEL #080205 18598. ---
SURVEYOR'S CERTIFICATE
I, SAMUEL D. PHELPS, DO HEREBY CERTIFY THAT I AM A REGISTERED LAND SURVEYOR UCENSED UNDEr\ 'l ·lt. ~..;·.-•:-' •
lliE STATE OF COLORADO, TI-iAT nilS PLAT IS A TRUE, CORRECT AND COMPLETE PLAT OF THE ·oAY Su6C·;'/l ':l0'
EXEMP110N PLAT", GARFIELD COUNTY, COLORADO, AS LAID OUT, PLA TIED, DEDICATED AND SHOWN HEkE OtJ . Th.A T -•-:, ..
PLAT WAS MADE FROM AN ACCURATE SURVEY OF SAID PROPERTY BY ME AND UNDER MY SUPERVISION M J[ t,L F<:--i:, :..
THE LOCATION AND DIMENSIONS OF "0--E LOTS, EASEMENTS AND STREETS OF SAID SUBDIVISION AS THE S.:.1.\E .t._. .. r "'r.~
UPON 1HE GROUND IN COMPLIANCE WITH APPUCABLE REGULATIONS GOVERNING TI-iE SUBDIVISI ON OF LA~ID .
IN WITNESS WHEREOF I HAVE SET MY HAND AND SEAL THIS DAY OF ________ _
BY: ______________________________________ ___
SAMUEL D. PHELPS
COLORADO REGISTERED PROFESSIONAL
LAND SURVEYOR # 27613
:.
J
~
l<t~
feMUJ 3
:Vcyf Sub iJJA4fif/fP1
N~ 7+ g-re~lj ~~ot~ br
:5 vf) r) .bif tJ-'1 A..eff. --' .
(!_ D / ~J !j/ir j )._
15
AooP
II ab~ I
~'
................................................................................................................................................................................................................ ~~----~~ ... ~-.. -------------J-
¥~
Ffotr1
7!2-
(!;()
109 8th Street Suite 303
Glenwood Springs, Colorado 81601
Phone (303) 945-8212
INDIVIDUAL SEWAGE DISPOSAL PERMIT
PROPERTY
Present Address 206 Srl29.J)y LJ.J. ~~~.
·--;) Q Cb ' --It ..v;:J PfW@IliPlU. 1-· I J
Owner's Name S~c,L,' /{1'-Q Y '
System Locatiof"l "?fC{~ 16u 7J1i..( c \II
SYSTEM DESIGN
--------Septic Tank Capacity (gallon) ________ Other
-----Percolation Rate (minutes/inch) Number of Bedrooms (or other)-----
ReqUired Absorption Area· See Attached
Special Setback Requirements:
Permit N: 3960
Assessor's Parcel No.
Th is does not const itute
a building or use permit.
Phone~-2.""57. 72 ..9 ?
Date ______________ Inspector ---------------------------
FINAL SYSTEM INSPECTION AND APPROVAL (as installed)
Call for Inspection (24 hours notice) Before Covering Installation
Sy~emln~a~r·-----------------------~~~~-------------~ Sep~c~nk Capac"Y---------~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~---------
Septic Tank Manufacturer or Trade Name------:;...--...:--------------------------
Septic Tank Access within 8 " of surface -----.S,.-------::fi:~.Jclf=-!"'-t~!U..\ _..J.E'm=.!..:!::::::r..LILrt-U-(lL-1~~~-----------
Absorption Area -----------~---------------------------
Absorption Area Type and /or Manufacturer or Trade Name ~------------------------
RETAIN WITH RECEIPT RECORDS AT CONSTRUCTION SITE
•CONDITIONS:
1. All installation must comply with all requirements of the Colorado State Board of Health Individual Sewage Disposal Systems Chapter
25, Article 10 C.R .S. 1973, Revised 1964.
2. This permit is valid only for connection to structures which have fully complied with County zoning and building requirements. Con-
nection to or use with any dwelling or structures not approved by the Building and Zoning office shall automatically be a violation or a
requirement of the permit and cause for both legal action and revocation of the permit.
3. Any person who constructs, alters. or installs an individual sewage disposal system in a manner which involves a knowing and material
variation from the terms or specifications contained in the application of permit commits a Class I, Petty Offense ($500.00 fine-6
months in jail or both).
While· APPLICANT Yellow • DEPARTMENT
b~/2e12ea7 14:57 s7e-7e4-6313 SOPRIS ENGINEERING
FAX Transmittal
Tl: Andy Schwaller
Clllllau: Garfield County Building Department
fu#: 384 3470
late: 9-20-07
TIIIIPIIIS: 4
SEPraJICIII. 240201.01
l'fom: Paul Rutledge
PAGE 61
111111e: Attached is the, As-Built Certification Jetter for George Kilby
improvements, at Parcel 3, Day Subdivision, addressing the OWS
and the Finish Floor Elevations. Tf you have any questions please
can me.
o Original not to foll ow
o Original to fo llow by mall
o Original to be delivered by messenger
o Original to be picked up
lso2 ma i n street • suite A3 • carbo ndale . CO 81623 • (970) 704 -0311 • fax (970) 704-0313]
SOPRIS ENGINEERINO • llC civil consultants
e9/20/2BB7 14:57
George Kilby
505 Sandy Lane
Annisto~ AL 36207
Andy Schwaller
970-704-0313
Garfield County Building Department
108 gth Street, Suite 401
Glenwood Springs , CO 8160 1
SOPRIS ENGINEERING PAGE 02
September 20, 20071
RE: As-Built Onsite Wastewater System and As-Built Finish Floor Documentation for the Kilby
Property. Parcel 3, Day Subdivision. Garfield County, CO
SE Job No. 24020.01
Dear George & Andy:
Pursuant to County Regulations, this Jetter provides documentation that the new Onsite Wastewater
System (OWS), installed approximately 3 years ago. is in general compliance with the permitted design.
This letter also documents the As-built conditions of the Garage-ADU Structure in tenns of the Finish
floor elevation. with respect to the base flood elevation (BFE).
Sopris Engineering has petformed site visits to measure, inspect. and document the as -built conditions of
the constructed system. We have coordinated our efforts with the treatment system installer, and the
contractors that constructed the system. The system was inspected prior to backfilline and after all
installations was completed . The as-buHt conditions and installation of the new OWS components is in
compliance with the permitted design specifications for the system. The as-built field dimensions and
location of the new OWS treatment components were installed with respect to existing site conditions and
are marked in the field by the component risers and inspection ports installed to the finish surface grades.
In addition we have checked the system in coordination with the Service provider that has performed
required standard maintenance. bi-annually, pursuit to the ongoing maintenance agreement contract
The System was installed in accordance with Garfield County Regulations; the design parameters
presented in the Sopris Engineering design drawing, dated ApriJ 30, 2004 and the design report, dated May
6, 2004. A l 500-gallon dual compartment septic tank was installed with an Orenco Systems, Tnc .
Advantex AX-20 treatment system installed with the septic tank. The Advantex re-circulating packed bed
filter assembly was instaJied by a qualified installer. The system has a 24" diameter by 7' deep Orenco
dosing pump basin installed adjacent to the septic tank. The simplex pump assembly is designed to
pressure dose treated effluent to the perforated field laterals through a distribution manifold. The systems
control box has a remote telemetry unit that shares a connection to a phone line. A Three-year inspection
and maintenance agreement is in place, which provides for routine maintenance and inspections every 6
months by a qualified service provider. The maintenance agreement contract is due for renewal next year.
The last regular maintenance and inspection was pcrfonned by SCG on July 2, 2007.
jso2 Main Street • Suite A3 • Carbondale, CO 81623 • (970 } 704-0311 • Fax (970} 704~0313 I
SOPRIS ENGINEERING • llC civil consultants
6~/2e/2e67 14:57 97 6-704-6313 SOP RIS ENGINEER ING PAGE 0 3
George Kilby
SE Job No . 24020.01
September 20, 2007
Page2
The Dispersal field was constructed with as a mounded bed containing 3 rows of 12 standard infiltrator
chambers each 75' in length as generally delineated on the site plan. Flow is split equally between the
chamber rows through the pressure manifold to the individual distribution laterals running the full length of
the chamber rows. Inspection ports were installed on each end chamber and on the head comer chambers.
The overall dimension of the dispersal field is 75 ' by 9' mounded approximately 3.25-feet above the
natural surface grade. The field was installed level with the chambers installed over 24-inches of filter
sand overlying suitable native soils. Suitable native soil is backfilled over and around the chambers. The
24-inch layer of filter sand below the leaching chambers provides a basal area ofapproximately1400 S.F .
Treated effluent from the septic tank/ Advantex treatment system is pressure dosed to a manifold at the
head of the bed. The flow is equally split to each row in the field. Each chamber row has a 4" inch
perforated PVC distribution pipe running the length of the row. The construction was completed utilizing
specified materials installed according to design. The minimum setback distances have been maintained.
Advantex AX-20
The advanced treatment system installed is an Orenco Systems Advantex-AX·20 unit (re·circulating
trickling packed bed filter). The system is capable of producing effluent quality which meets or exceeds
the requirements of the US EPA for secondary wastewater treatment (30mg/L BOD and 30 mg/L
suspended solids). The dispersal field is sized to adequately service (4) bedrooms. AllOWS components
are accessible from the surface to facilitate system testing and maintenance. The return flow is discharged
back to the secondary compartment for nitrogen removal. The Advantex AX-20 is designed to provide
treatment resulting in effluent water quality parameter levels of 30 mg/L BOD and 20 mg!L TSS based on
a design flow of 1125 gpd.
Maintenan~e Protocol
The engineered system shall continue to be inspected on a regular basis and be properly maintained .
Ownership of the system and responsibility for construction! repair and maintenance will remain with the
Lot Owner. The Owner shall continue to retain the services of qualified persotulel to inspect the OWS and
to perfonn all maintenance and repairs necessary to ensure that the system is functioning properly, is in
good operating condition and is in compliance with the manufacturer's performance requirements. The
operating components of the OWS system will be serviced and inspected bi-annually.
Garage-ADU Finish Floor Elevation & Base Flood Elevation
The Garage -ADU structure was constructed that includes a 1-bedroom studio apartment over a single
garage with adjacent accessory space. An adjacent 3-bedroom single-family home will be built in the
future. The new garage-ADU structure is generally located as shown on the design plan.
Applicable floodplain information for the site was referenced from the FEMA; FIRM map (panel No.,
080205 1880 B) dated January 3, 1986: which indicates that a portion of the site is in Zone A. The t 00-
year base flood elevations (BFE) across the site range from 6186 to 6192 as delineated on the FIRM map.
0~/26/2007 14 :57 970-704-0313 SOPRIS ENGINEERING PAGE 04
George Kilby
SE Job No. 24020 .01
September 20t 2007
Page 3
The As~built finished floor elevation of the garage slab is 6190.87 feet MSL. approximately 1.5 fect: above
the BFE of 6189.40. The adjacent accessory space dwelling finish floor elevation is 6191.44 feet MSL,
approximately 2 feet above the BFE of6189.40. The existing grades shown on the plan are based on a
recent topographical survey by Sopris Engineering, using the 1929 vertical datum as referenced on the
FEMA map. The Finish Floor elevations were recently surveyed by Sopris Engineering, using the 1929
vertical datum.
If you have any questions or need any additional infonnation, please call.
Sincerely,
SOPRIS ENGINEERING, LLC
Paul utledge
Design Engineer
Cc: Andy Schwaller
''
on-' ... As~~-~or's Parcel No ~24-!.:i, -=)Sf -O' -u~CJ
Date t{-· I I -c.}/
Owner
1
AddressS:f">Sor'l~jla ~f\~\h
Contracton() ll "N)QC: Address _________ _
Setbac~s:. . Fro~t \. .. ~ea~ . 'C-RH LH Zoning ~tt'JrrtJ-t~~£c:Srf;,;ecTtoNs S(f=""wf~~+~ ~ ~;~~~-T~g ~ (;?latherproofing
Footing W -c, '"0~ Mechanical _________ --:-.::or.::::r----
Foundation /4-8 "'()~ Electrical Rough (State ) 11-4.2--as" IBP
Grout Electrical Final (State ) ___ .Lo;, /:::...._ ___ ._.....,~-
1 Underground _Plumbing /~-~-dcfrl1tf= 1..Fina~. (. · 2 2 --<::'7/Checklist Completed? ~ 7
1\'"Rough Plumbmg Jz -L-C' ~Z1/ Certtflcate Occupancy # ~~~':....4.!..2-::::::..._ ____ _
' Framing l/-pllf.:<>6 J1/>AP-Date --!b:;?:::-2.~2=---=o=--~~;;-------
lnsulation {2.-t&b~ Septic System# _?f\(cD -f~~ ~
Rooting " Q~ Date ~w""---...L.I.J..I-.....!o ... A-:....~. ______ _
Drywall 3.-c C'J._ I J.. Final ___________ _
Gas Piping C:·-l7t;75f" Other ------------------
,....-,--~-' d /. -/) (~. r -~~~ ~t~ ~ ~/'( CA4~J. ~ry f).~("s ~~o..r~ -prJ.
CJJ(II{o q -k:l.(tt! oy , . 1 . L ·1--=$ t oq. iY 7 /.)...7/ o_r
_.h ,; • • , ,~ JZ: ,L.Jc. 1 17 c t-(continue on back)
-J( /( "t tYl ... • 11 r:· /ft,,.-rt .u~-
FINAL CHECKLIST
MECHANICAL ROj)M
Boiler ,L_
Hot water _________ _
F.A gas/oil _________ _
Floor drain _________ _
Clearance _________ _
Air con. system __ -;".-:,~----
Hot water heater -....\/~7'=~-----
Combustion air_-J,JZL_ _____ _
Gas piping, valves _______ _
LPG Drain ----------
FIREPLACE/STOVE
REMARKS
. '
BUILDING PERMIT
GARFIELD COUNTY, COLORADO
Date lssuedC..-:ll~ .•• ~.4. ... Zoncd Area ............................... Permit No.9.J..l.9 .............. .
AGREEMENT
In consideration of the issuance of this permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location; construction and erection of the proposed
structure for which this permit is granted, and further agrees that if the above said regulations
a re not fully complied with in tl1e zoning, location, erection and construction of the above
d escribed structure, the permit may then be revoked by notice from the County Building
Inspector and IMMEDIATELY BECOME NULL AND VOID.
Use~~&, tJ1 J'If (.,•,., .S,s c£ ~loe'l
Address or Legal Description _____________________ _
Owner Contractor
Setbacks Front Side Sid.L----R.ca.t.. _ -----
T bls Canl .Must Be Posted So It is l'lalnly Visible From Tbe Street Until Final Inspection.
INSPECTION RECORD
Footing 1 b -U .. 6 'f 1:£.
Foundation £0.-.YJ~U~
Underground Plumbing Ja,.7 ~.ofl'f rJ-Insulation il2-t8 .Qrp7} {-_
Rough Plumbing lJ.-r-tJro ~ Drywall 3-g -0 _7 J s
Chimney & Vent eu.. '/fl/o/ ~ 0~
Gas Piping ~-l-D~I/1:-Final C-~-()?"7?7/72-
Septic Final
Framing 11~~-ob'~ Notes:
(To indude Roof in place and Windows
and Doors installed).
I ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED DEFORE COVERING -
WIIETIIER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND.
f,tt-. fl.ov~ll 0~ THIS PERMIT IS NOT TRANSFERABLE
PIJJ(e"iff-so!J 109 8th Street County Courthouse Glenwood Springs, Colorado.
APPROVED
• Date By ____ _
IF PLACED OUTSIDE-COVER WITH CLEAR PLASTIC