HomeMy WebLinkAboutBP-59190327
Job Address
GARFIELD COUNTY
BUILDING, SANI7A77GNand PLANNING DEPARTMENT
109 lith Street Suitt 303
Glenwood Springs, Colorado K1601
(303) 945-1212
Nature of Work Building Permit
Use of Funding Single Family Dwelling TTni1-
Owner
Robert & Mary Proctor
, Sierra Vista RanLh, Lot 14,_Silt
Contractor Owner
Amount of Permit S
1,472.21
Permit: 892.25
Plan : 579.96
Paid $579.96 5-9-96
Dale June 3, 1996
S. Archuleta
Clerk
BUILDING PERMIT APPLICATION
GARFIELD COUNTY, COLORADO
Applicant to complete numbered spaces only. PERMIT NO. 6-9M PARCEUSCHED NO.
, %-
Joe An 13 ss -$�. 33 // �/ Lr-
1
LEGAL
DESCR.
LOT NO.
BLOCK
j L -
SUBDIVISION SI fI/6� U 15T6, 1�a,(��
1r.
2
OWNER ?"1- O C`�6
ADDRESS �a �j3 335RUT- pi.
Cy
PH. laL{-D�JQr
V •V
WK PH.
3
CONTRACTOR 0 \�-% rv� r--
ADDRESS S F t rnC.
PH.
LICENSE NO.
4
N a_4.0 na..l
ARCHITECT OR DESIGNER l>Latn S e... -.f ICA.,..
ADDRESS
PH.
LICENSE NO.
5
ENGINEER
ADDRESS
PH,
LICENSE NO.
6
\ r t5hCa 123 d-
SF OF BUILDINGScr(\ FiAst'.ed 123.).
12 p
S.F OF LOT .21 etc(
HEIGHT ICI, lr1
NO. OF FLOORS
7
USE OF BUILDING OTO en e
8
CLASS OF WORK: 'EW InADDITION oALTERATION O REPAIR oMOVE °REMOVE
9
DESCRIBE WORK:
10
GARAGE SINGLE DOUBLE CARPORT SINGLE DOUBLE
DRIVEWAY PERMIT ON SITE SEWAGE DISPOSAL PERMIT SITE PLAN
11
VALUATION OF WORK $ ADJUSTEDVAL.$
PLAN CHECK FEE 579.96
//r�
PERMIT FEE/g9a. #g 3 -
SPECIAL CONDITIONS: /2.32 a' K 4..C.-2-9 .7 q VSCHOOL
•
/2 3a Q'� /c, . 3(o _ oo/0 '
IMP
FE 0 7f
4 CQ
NO. OF BUILDINGS ON
PARCEL
USE OF BUILDINGS NOW ON
PARCEL
TOTAL Hai 5r 2 lii2r
' WATER SUPPLY
OCC. GR. 6-3-94
DATE PERMIT ISSUED
CONST. TYPE
SEPARATE PERMITS
VENTILATING OR AIR
THIS PERMIT BECOMES
NOT COMMENCED WITHIN
OR ABANDONED
COMMENCED.
I HEREBY CERTIFY
THE SAME TO BE TRUE
GOVERNING THIS TYPE
HEREIN OR NOT.
AUTHORITY TO VIOLATE
-LOCAL •TON,
CON CTION.
NOTICE
ARE REQUIRED FOR ELECTRICAL, PLUMBING, HEATING,
CONDITIONING.
NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS
180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED
FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS
THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW
AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES
OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED
THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE
OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR
rIEF+ i G CONSTRUCTION THE I�RF MANCE OF
7•�
SPECLOL APPROVALS
REQUIRED
REeelvEo�/
NOT REQUIRED
ZONING
.�
(y0,/
�5_ j��
_
HEALTH DEPT.
1
FIRE DEPT.
SOIL REPORT
SETBACKS
j�
FLOOD HAZARD
Signature of �Ow\ = , Cbniractor
or authorized agen a ' .. / :.... notic- . bov..
V--
MANUF. HOME
V.“AArl O. S. La «6
Y
Building 'Mr. Department Aggravate] e p Planning Depa Ent A.. • -•
j
OTHER15'f%S
/So , D
AGREEMENT
PERMISSION IS HEREBY GRANTED TO THE APPLICANT AS OWNER, CONTRACTOR AND/OR THE AGENT OF THE CONTRACTOR OR OWNER TO
CONSTRUCT THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT
IN CONSIDERATION OF THE ISSUANCE OF THIS PERMIT THE SIGNER HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND USE
REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN IN 30.28.201 CRS AS AMENDED. THE SIGNER FURTHER
AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPLIED WITH IN THE LOCATION, ERECTION, CONSTRUCTION AND USE OF
THE ABOVE DESCRIBED STRUCTURE. THE PERMIT MAY THEN BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT
SHALL BECOME NULL AND VOID.
THE ISSUANCE OF A PERMIT BASED UPON PLANS, SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE BUILDING OFFICIAL FROM
THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING BUILDING
OPERATION BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF THIS CODE OR ANY OTHER ORDINANCE OR REGULATION OF THIS
JURISDICTION.
THE REVIEW OF THE SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN
ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABILITIES 8Y GARFIELD COUNTY FOR ERRORS, OMISSIONS OR DISCREPANCIES. THE
RESPONSIBILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICALLY WITH THE ARCH CT, DESIGNER,
BUILDER AND OWNER. COMMENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS INTEREST.
Garform.003 1 HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE INI IAL
GARFIELD COUNTY BUILDING AND PLANNING
MINIMUM APPLICATION REQUIREMENTS
for
SINGLE FAMILY DWELLING CONSTRUCTION
including
NEW CONSTRUCTION
ADDITIONS
ALTERATIONS
and
MOVED BUILDINGS
In order to understand the scope of the work intended under a permit
application and expedite the issuance of a permit it is important that
complete information be provided. Adequate and complete information
will prevent delays in the plan review process. Reviewing a plan and the
discovery that required information has not been provided by the applicant
may result in the delay of the permit issuance and in proceeding with
building construction. The owner or contractor may be required to provide
this information before the plan review may proceed. This causes delays
because other plans that are in line for review may be given attention
before the new information may be reviewed after it has been provided to
the Building Department.
Please review this document to determine if you have enough information
to design your project and provide adequate information to facilitate a plan
review. If you do not, it may be helpful to obtain a book titled Dwelling
construction under the Uniform Building Code. This book is available to
you through this department at our cost. Also, please consider using a
design professional for assistance in your design and a construction
professional for construction of your project.
To provide for a more understandable plan in order to determine
compliance with the building, plumbing and mechanical codes, applicants
are requested to review the following check list prior to and during design.
Applicants are required to indicate appropriately and to submit completed
check list at time of application for a permit:
1
T. Is a site plan included that indicates the distance of the proposed
building or addition to property lines, other buildings, set back
easements and utility easements?
Yes _x,_ No cn Not necessary for this project (2)
2. Does the site plan include the location of the I.S.D.S. (Individual
Sewage Disposal System) and the distances to property lines, wells
(on subject property and adjacent properties) , streams or water
courses?
Yes A No ____cu Not necessary for this project (2)
3. Does the site plan indicate the location and direction of the County or
private road accessing the property?
Yes _ No (1) Not necessary for this project (2)
4. Do the plans include a foundation plan indicating the size, location
and spacing of all reinforcing steel in accordance with the uniform
building code or per stamped engineered design?
Yes X _ No (1) Not necessary for this project (2)
5. Do the plans indicate the location and size of ventilation openings for
under floor crawl spaces and the clearances required between wood
and earth? y
Yes No (1) Not necessary for this project _Xc_(2)
6. Do the plans indicate the size an location of ventilation openings for
the attic, roof joist spaces and soffits?
Yes _ No 1) Not necessary for this project
7. Do the plans include design loads as required under the Uniform
Building code for roof snow loads, (a minimum of 40 pounds per
square foot in Garfield County) floor loads and wind loads?
Yes _ _ No n> Not necessary for this project (2)
8. Does the plan include a building section drawing indicating
foundation, wall, floor and roof construction?
Yes _(__ No _____a, Not necessary for this project
9. Does the building section drawing include size and spacing of floor
joists, wall studs, ceiling joists, roof rafters or joists or trusses?
Yes _X__ No (1) Not necessary for this project (2)
10. Does the building section drawing or other detail include the method
of positive connection of all columns and beams?
YaS.�-
2
Yes I-_ No _____u, Not necessary for this project (2)
11. Does the plan indicate the height of the building or proposed addition
from the highest point of the building or addition measured at mid
span between the ridge and the eave down to existing grade contours?
Yes _,.r(_ No a) Not necessary for this project
12. Does the plan include any stove or zero clearance fireplace planned
for installation including make and model and Colorado Phase II
certifications or phase II EPA certification?
Yes No (1) Not necessary for this project , &(2)
13. Does the plan include a masonry fireplace including a fireplace
section indicating design to comply with the Uniform Building Code
Chapter 37? `J��,5"
Yes No _(n Not necessary for this project _[�_(2)
14. Does the plan include a window schedule or other verification that
egress/rescue windows from sleeping rooms and/or basements
comply with the requirements of the Uniform Building Code?
Yes _22 _ No ..____a, Not necessary for this project ____(2)
15. Does the plan include a window schedule or other verification that
windows provide natural light and ventilation for all habitable rooms?
Yes _ No _____o) Not necessary for this project (2)
16. Do the plans indicate the location of glazing subject to human impact
such as glass doors, glazing immediately adjacent to such doors;
glazing adjacent to any surface normally used as a walking surface;
sliding glass doors; fixed glass panels; shower doors and tub
enclosures and specify safety glazing for these areas?
Yes _X__ No a) Not necessary for this project (2)
17. Is the location of all natural and liquid petroleum gas furnaces,
boilers and water heaters indicated on the plan?
Yes _�_ No ,) Not necessary for this project (2)
18. Have two (2) complete sets of constructions drawings been submitted
with the application?
Yes No (0 Not necessary for this project (2)
19. Have you designed or had this plan designed while considering
building and other construction code requirements?
Yes _A__ No 3)
3
20. Does the plan accurately indicate what you intend to construct and
what will receive a final inspection by the Garfield Building
Department?
Yes 2k__ No (3)
21. Do you understand that approval for design and/or construction
changes are required prior to the application of these changes?
Yes Lc_ No (3)
22. Do you understand that the Building Department will collect a "Plan
Review" fee from you at the time of application and that you will be
required to pay the "Permit Fee" as well as any "School impact" or
"Septic system " fees required, at the time you pick up your building
permit?
Yes _2L_ No (3)
23. Are you aware that you are required to call for all inspections
required under the Uniform Building Code including approval on a
final inspection prior to receiving a Certificate of Occupancy and
occupancy of the building?
Yes _ ,_ No (3)
24. Are you aware that the person signing the Permit Application whether
the "Owner", "Agent of the Owner", "General Contractor", "Contractor"
or otherwise, signing the application is the party responsible for the
project complying with the Uniform Codes".
Yes _ No
I hereby acknowledge that I have read, understand and answered these
questio accurately to best of my ability.
5c g --
date
Phone: l 0 7 '.1/ days); (evenings)
t
Project Name: (AJC i Re s \ Cite_A'lL
Project Address: l—O`i 1± i l %k -eel -CI (1{i, p„_L
4
Notes:
(1) If you have answered "No" on any of these questions you may be required to provide this information at
the request of the Building Official prior to beginning the plan review. process. Delays in Issuing the
permit are to be expected. Work may not proceed without the Issuance of the permit.
(2) if you have answered "Not necessary for this protect" on any of the questions and it Is determined by
the Building Official that the information is necessary to review the application and plans to determine
minimum compliance with the adopted codes, please expect the following:
A. The application may be placed behind more recent applications for building permits In the
review process and not reviewed until required Information has been provided and the
application rotates again to first position for review.
B. Delay in issuance of the permit.
C. Delay In proceeding with construction.
(3) If you answered "No" to this question the circumstances described in the question could result In a 'Stop
Work Order" being issued or a "Certificate of Occupancy" not being issued.
PerApp01.94 Effective May 1, 1994
5
RIGHT J LOAD AND EQUIPMENT SUMMARY
For: PROCTOR RESIDENCE
N/A
SILT
N/A
By:
CLIMATE CONTROL COMPANY
1537 130 ND"
GLENWOOD SPRINGS
970-945 2326
WINTER DESIGN CONDITIONS
Outside db:
Inside db:
Design TD:
HEATING SUMMARY
Bldg. Heat Loss
Ventilation Air
Vent Air Loss
Design Heat Load
O Deg F
70 Deg F
70 Deg F
44785 Btuh
O CFM
O Btuh
44785 Btuh
INFILTRATION
Const Qual a
# Fireplaces 0
HEATING COOLING
Area (sq"ft,) 2408 2408
Volume (ce.ft.) 19264 19264
Air Changes/Hour 0^7 0.4
Equivalent CFM 225 129
HEATING E8UIPMEN/ SUMMARY
Make TRANS
Model
Type
Efficiency / HSPF
Heating Input
Heating Output
Heating Temp Rise
Actual Heating Fan
Htg Air Flute: Factor
Space Thermostat
0.0
0
@
690
0"@15
Btuh
Etuh
Deg F
CFM
CFM/Btuh
7 23-95
CO 81602
Job #:
Wthr : GraU_Junction_AW_(S> CO
Zone
SUMMER DESIGN CONDITIONS
Outside db:
inside db:
Design TD:
Daily Range
Rel" Hum" :
Grains Water
94
75
19
H
50
@
Deg
Deg
Deg
�
Ur
SENSIBLE CODLING EQUIP LOAD Sl[ING
Structure 12900 Etuh
Ventilation Q Stun
Design Temp. Swing 3,0 Deg F
Use Mfg. Data n
Rate/Swing Mul*" 1"00
Total Sens Lquip Load 12900 Btuh
LATENT COOLING EQUIP LOAD SIZING
Internal Gains
Ventilation
Infiltration
Tot Latent Equip Load
O etuh
O Btuh
m Btuh
O Ptyh
Total Equip Load 12900 Btuh
COOLING EQUIPMENT SUMMARY
Make TRANE
Model
Type
COP/EER/SEER
Sensible Cooling
Latent Cooling
Total Cooling
Actual Cooling Fan
rlg Air Flow Factor
m.m
O 'Stuh
0
Btuh
O Btub
690 CFM
0"053 CFM/Btuh
Load Sens Heat Ratio 100
MANUAL J: 7th Ed. RIGHT -J: V1^74 S/N !!!!
Printout certified
by ACCA to meet all requirements of Manual Form
RIGHT ,I CALCULATION PROCEDURES A, B,
Job {h : 7--23-951
Procedure H -- Winter Infiltration HIM Calculation*
I 1. Winter "infiltration CFM
0.7 AC/HR x 19264 Cu. Ft. x 0.0167 225 CFM
Winter Infiltration Btuh
1.1 225 CFM 70 Winter 1D -- 17340 Btuh
I 3. Winter '1iifiltratinn HTM
17340 Btuh J 240 Total Window = 72.3 HTM
& Door Area
Procedure B• -- Summer infiltration HTNI Calculation*
I 1. Summer Infiltration CFM
0.4 HC; HR x 19264 Cu. Ft. x 0.0167 129 CFM
I 2. Summer infiltration Btuh
1. 1 x 129 CFM x 19 Summer TD = 2689 Btuh
Summer infiltration HIM
2689 Btuh 240 Total Window -- 11.2 HIM
&- Door Area
Procedure 0 -- Latent Infiltration Gain
0.68 x 0 gr. diff. x 129 CFM = Vi Btu..ih
Procedure D -- Equipment Sizing Loads
1. Sensible Sizing Load
Sensible Ventilation Load
1.1. x 0 Ven't.CFM x 19 Bummer TD = 0 Btuh
Sensible Load for Structure Wine 19) -i- 12900 Btuh
Sum of Ventilation and Structure Loads = 12900 Btuh
Rating and Temperature Swing Multiplie r: 1.00 RSM
Equipment Sizing Load -- Sensible + 12900 Btuh
2. Latent Sizing Loac
Latent Ventilation Load
0.68 x 0 Vent.CFR1 x 0 gr. diff.
Internal Loads -- 230 x 0 No. People
infiltration Load From Procedure 0
Equipment Sizing Load — Latent
{-
4i Btuh
• Btuh
O Btuh
O Btuh
*Construction Quality is: a No. of Fireplaces is: 0
MANUAL 3: eth Ed. RIGHT --J: V1.74 a:N I'll
Printout certified by RCCA to meet all requirements of Manual Form J
Joh #: Zune: /-23- z
----- MANUAL J: 7th Ed. --'- RIGHT -j: V1.74 ---- S/N !!!! --- Page 1
11 Name of Room | Entire House | BASEMENT i
21 Running Ft. Exposed Wall | 284.0 Ft^ | 144.0 Ft" l
3i Room Dimensions, Ft. | | 44.0 x 28.0 Ft. |
| 41 Ceilngs,Ft 1 Condit. Opti"ni 8.0 1 1 8.0 | heat/cool |
' |'-------^-----------|
'| TYPE OF | |CST| HTM | Area | Btuh i Area 1 Btuh |
|. EXPOSURE 1 INO, |Htg |Clg |Length| Ht8 i Clg |Length| Htg 1 Clg 1
|.__^___ __------------------------------^------|-~'-----'-------^---(
| 51 Gross |a|12D| 5.61 1.41 11201 **** 1 **** 1 01 **** 1 **** }
| 1 Exposed 1h115B1 5.21 0.01 8001 **** 1 **** 1 8001 **** 1 **** |
1 Walls and 1c11401 5.41 0.61 3521 **** | **** 1 3521 **** | **** 1
1 Partitions \d1 1 0"01 0^01 01 **** 1 **** | 01 **** 1 **** |
1 lei | 0.01 0.01 01 **** 1 **** 1 01 **** | **** |
| |f| | 0"01 0"01 01 **** 1 **** i @| **** 1 **** 1
---------~----`--------------'-|------^-^^^--'------|--------------------|
61 Windows lal 30150.81 ** 1561 79171 **** 1 561 28421 **** 1
| | & Glass |b| 80150"81 ** | 421 21321 **** 1 01 01 **** |
| | Doors Htg. |c| 9I152.81 ** | 421 22171 **** 1 211 11081 **** 1
| | |d| | 0"01 ** | 01 01 **** | 01 Oi **** i
i |
lel 1 @,@| ** i @i 01 **** 1 01 01 **** 1
| | |fi | 0.01 ** i 01 01 **** | 01 Qi **** |
|-'---------------------'-------|----~---~-----------|-------`------------|
| 71 Windows 1 North 123"01 1061 **** | 24381 241 **** 1 552|
| | & Glass i NE&NW 1 0"01 01 **** 1 Q| 01 **** | 01
| | Doors Clg. 1 E&W | @"Q| 01 **** | 01 01 **** | 01
| } i SE&SW ) 0.01 01 **** 1 01 01 | 01
| i
1 South 138^01 1341 **** 1 50921 531 **** | 20141
| |
1 H"rz i 0.01 01 **** 1 @i Q| **** 1 m|
|--~----``-----------------|-'`--------------'--|-----------^------`-|
|
81 Othr doors 1a110D132.21 8.11 01 01 @| 0! 01 N|
1 |b| | 0.01 0.01 01 01 Q| 01 01 01
|-------------------------------1--------------------1----------------`---1
|
91 Net |a|12D1 5"61 1"41 8801 49381 12391 -771 -4311 -1081
| | Exposed 1b11581 5.21 0.01 8001 41441 01 8001 41441 01
| | Walls and |c114131 5.41 0.81 352i 18971 2791 3521 18971 2791
| |
Partitions |d| 1 0.01 0.01 01 01 01 01 01 0|
| |
lel | 0.01 0.01 01 01 01 01 01 01
i | |f| | 0"01 0.01 01 01 01 01 m| 01
|---------------------------'---|--------------------|------------'``-----1
1101 Ceilings 1a116H1 1"81 1.01 11761 21401 11621 01 01 01
| 1 (b| 1 0.01 0.01 @| 01 01 01 01 01
| 1 101 | 0.01 0.01 @| 01 01 01 01 01
i----'------------------------`-|--------------------|---------------~----|
1111 Floors |a121A1 1.71 Q"N| 12321 20701 01 12321 20701 01
| 1 ih| 1 0.01 0"01 01 01 01 01 01 a|
| 1 |r| 1 0.01 0.01 m{ 01 01 01 @| 01
|-------------------------------|------^-------------|--------------------|
1121 Infiltration a 172"3111.21 2401 173401 26891 771 55631 8631
|----------------~---'^-`-------|-----'--------------i--------------^-----|
1131S"btot Btuh Loss=6+(}""+1l+121 **** 1 447851 **** i **** } 171941 **** ;
1141 Duct Btuh Loss 1 m%| N| **** 1 0%1 01 **** 1
1151 Total Btuh Loss = 13+14 | **** 1 447851 **** 1 **** | 171941 **** 1
|---------------------'---------|------~^-^`~--------|-~-~~-------------^-|
1161 Int. Gains: People @ 3001 01 **** 1 01 01 **** 1 01
| 1 App]. @ 12001 01 **** 1 01 0| **** 1 m|
1171 Subtot RSH Gain=7+8..+12+161 **** 1 **** | 129001 **** 1 **** 1 36001
1181 Duct Btuh Gain | @%| **** 1 W| @%| **** | 01
1191 Total RSH Gain 17+18 1 **** 1 **** 1 129001 «*** 1 **** 1 36001
1201 CFM Air Required 1 **** 1 6901 6901 **** | 2651 1921
- Printout certified by ACCA to meet all requirements of Manual Form J --
Job #: Zone: 7-23-95
. MANUAL J: 7th Ed. RIGHT-J: V1.74 S/N !!!! --- Page 2 '---
1| Name of Room 1 GREAT ROOM/FOYER | KITCHEN/DINING |
21 Running Ft. Exposed Wall | 35.0 Ft. | 35.0 Ft. |
31 Room Dimensions, Ft. | 21.0 x 14"0 Ft" 1 21.16 x 14,0 Ft" |
41 CeilngsxFt | Condit. Option! 8.0 1 heat/cool 1 8.0 1 heat/cool i
-|- '|
TYPE OF 1 |CGT| HTM | Area 1 Gtuh 1 Area i Stub i
EXPOSURE | |NO.iHtg |Cig (Length| Htg 1 C18 'Length' Htg | Gig |
| |
51 Gross |a|12D1 5"61 1.41 2801 **** | **** | 2801 **** | **** |
Exposed 1h!1561 5.21 0.01 01 **** | **** | 01 **** 1 **** |
Walls and |c114015.41 0"81 0| **** **** | 01 **** | **** i
Partitions |d| 1 ��,0| ��"0| @| **** 1 **** ) 01 ***� | **** |
lel 1 m"@| @.m| @| **** | **** 1 mi **** 1 **** |
|fi | 0.01 0.01 01 **** i **** i 0| **** i **** |
------------------`-^----}`----------------- -|--~-----------------|
61 Windows lal 30150"8i ** 301 15231 **** 1 101 5081 **** 1
� & Glass |b| 80150"81 ** 01 01 **** | 421 21321 **** |
| Doors Htg. |c| 9I152.81 ** 211 11081 **** | 01 Q| **** |
|d| 1 0.01 ** 01 01 **** | 01 01 **** |
iei | 0.01 ** | 01 01 **** | 01 01 **** |
|f| 1 0"01 ** | m| 01 **** | 01 01 **** i
------------------^|--------------------|----------^-----____|
|
71 Windows North 123.01 01 **** 1 01 521 **** 1 11961
| & Glass | NE&NW | 0.01 01 **** | 01 01 **** | @i
} |
Doors Clg. | E&W 1 0.01 N| **** 1 01 01 **** | 01
| | | SE&SW ] m"0| 0| **** | 01 01 **** | 01
| | |
South |]8^0| 51| ***x | 19381 01 **** | 01
| | | Horz | 0.01 0! **** | @| @| »*** 1 01
|`---------------^--------------|--------------~-----|^-------------------|
8| Othr doors |a|10D132.21 8.11 01 01 01 @| 01 01
| | |b| | 0.01 0,01 01 01 01 O| m| 0|
|~----`----------------------^--)--------------------i-- ---------------i
9| Net |a|12D| 5"6| 1^4| 229| 128?| 322| P2H| 1�77| 3211
| Exposed 1b11561 5.21 0^01 01 01 01 01 01 0|
| Walls and 1c|1401 5"4| @"8| @| 01 0i m| @| 01
Partitions |d| | 0.01 @"Q| 01 01 01 01 @| 0i
|e| | 0^@| 0"01 m| 0| 01 01 Q| 01
|f| 1 @"@| 0.m| Q| 01 Q| Q| 01 N|
|------------------------ --^-|---~----------------i-~------------------|
110! Ceilings |a|16H1 1.81 1"01 2541 5351 2901 2941 5351 2901
I | |b| | N^N| 0.01 01 @| 01 01 01 01
| i ic| | 0.01 0.01 01 01 Qi 01 @| @|
|---`-----`---------------------|----------------~---|------~-------------|
1111 Flnors |a|21A{ 1"7| 0.01 0| 01 01 01 01 @|
| | |h| | 0.01 0.@| @| 01 Qi 01 01 0I
| | |c| | @,0| 0.01 01 Q| 01 01 Q| 01
|-----------------------`----'--|--------------------i------------`-------|
|12| Infiltration a |72"J|11.2| 51i 36851 5721 521 37571 5831
|i^------^----^-------i--^-----------------|
1131Sebtvt Dt"h Loss=6+8,,+11+i21 **** | 81331 **** | ***: | 82061 **** |
1141 Duct Btuh Loss | m%| 01 **** | 0%1 01 **** |
1151 Total Btuh Loss = 13+14 | **** | 81331 **** 1 **** | 82081 **** |
|-------------------------------|-------`---------~--|--------------------|
1161�Int. 8s/ins: People 0 3001 @| **** | 01 @| **** 1 01
| 1 Appl" @ 12001 0| **** i @| 01 **** | 01
|&71 Subtot RSH Gain=7+2^.+12+161 **** { **** i 31221 **** 1 **** | 23901
1181 Duct Stub Gain | 0%1 **** i 01 0%1 **** | @|
1191-Total RSH Gain = 17+18 1 **** | **** 1 31221 **** | **** | 23901
1201 CFM Air Required | **** | 12d| 1671 **** 1 1261 1281
,Printout certified by ACCA to meet all requirements of Manual Form J --
Job #: Zone: 7^23-95
----- MANUAL J: 7th Ed. -- - RIGHT -J: V1.74 S/N !I!! --- Page 3 '---
| 11 Name of Room | MASTER BED/BATH | BEDROOM *2 i
21RunnioO Ft. Exposed Wall 1 34.0 Ft. 1 24.0 Ft. \
31
Room Dimensions, Ft. 1 20.0 x 14.0 Ft. | 14.0 x 10"0 Ft. 7
41 Ceilngs,Ft | Condit, Option' 8.0 1 heat/cool | 8.0 1 heat/cool |
•------------------------------------------------|-------^----`-------|
TYPE OF i |CST| HT@ 1 Area | Btuh 1 Area | Btuh |
N EXPOSURE 1 |ND. |Htg !Gig 'Length' Mtg | Clg |Lengthl H+g i CIE /
|�------------'----^-------------^---'----------------|--------------`-----i
| 51 Dross |a|12D| 5.61 1.41 2721 **** | **** 1 1921 **** 1 **** 1
{ \ Exposed Ih<15R1 5.21 0.01 01 **** | **** | 01 **** 1 **** 1
1 Walls and |c114C1 5.41 0.81 01 **** 1 **** 1 m| **** 1 **** |
} Partitions idi | 0"01 0.1Z11 01 **** 1 **** 1 �| l iiii
| |e| | Q"Q| Q"0| @| **** | **** | 0| **** | | |f1 | m"@| m"0| m| **** | **** | 0| **** |
|------------ -
-----------------|--------------------|--------------------i
| 61 Windows |a\ 313150"81 | 301 15231 **** | i51 7611 *x** |
1 & Glass |h| 90150.81 +/* 1 01 01 **** | 01 01 **** 1
1 Doors Htg" \c| 9I152"81 ** ( 01 01 **** 1 01 01 **** |
] | Id! 1 0.01 ** 1 01 01 **** 1 01 01 **** |
1 lel | 0"01 ** 1 01 01 **** 1 01 Q| **** 1
| if' | 0^01 ** | 01 01 **** 1 01 01 **** 1
|-------------------------------|-----------------'--i---^~---------------|
/i Windows North 123"01 301 **** | 6901 01 **** 01
| � Glass NE&NW | 0"01 m| **** | m\ 01 **** 01
| Doors Clg" E&W 1 0.01 01 **** | 01 01 **** 01
1 SE&SW 1 0.01 Q| **** } Q| 0\ **** 01
| | South 138^01 01 **** | 01 151 **** | 570|
| ) Horz 1 @"@i @| :*** | @| Q\ **** | 01
|-------------------------------|-- '-i--------------------|
|
81 Othr doors |a110D132"21 8.11 @\ Q| @< 01 01 01
| |b| 1 0.01 0.01 01 01 01 01 01 01
|----------- -'------~----------1--------------------1-^-----^'-----'-----1
) 91 Net |a|12D1 5.61 1.41 2421 13551 3411 1771 9911 2491
| Exposed 1b11581 5.21 0.01 01 01 @\ 01 01 01
1 Walls and 1c11401 5,41 0"81 @| 01 01 @i 01 m|
| Partitions |d| 1 0.01 0.01 J| 01 W| 01 01 @|
lei | 0.0| @,@| 01 Ni 01 01 Q| 01
| |f| 1 0^01 0'01 01 01 @| 01 01 Oi
|--------------------`----------|-----'--- |----' |
|101 Ceilings |a|16H1 1.61 1"01 2801 510) 2771 1401 2551 1381
1 |b| | 0.01 0.01 01 01 01 01 Q| 01
i
1 |c| | 0^01 0.N| 0 01 01 01 01 0i
|-------------`--~----'^----^-~~|---^----^---^-------i-------`--------~---i
|111 Floors |a121Q1 1.71 0^01 01 01 Q| 01 01 01
1 |b! } 0"01 0"01 Q| 01 01 01 Q| 01
1 |c| 1 0.01 0.01 01 01 01 @\ @i m|
|-`-----------------------------|-----------`~'------I-'-~------^-- ^-----|
1121 Infiltration a 172"3111"21 30i 21681 3361 151 10841 1681
|---------------------'`------^-|~---- '-------------i--------------------|
|131E!"btnt Btuh Lsss=6+C1..+11+12| **** | 55551 **** | **** 1 30911 **** \
1141 Duct Btuh Loss | 0%1 01 **** | 0%1 01 **** |
1151 Total Btuh Loss = 13+14 1 **** 1 55551 **** 1 **** 1 30911 **** |
|-------------------------------|~-----'-----^--^--~-|-------'-~---^---
1161 Int. Gains: People 0 3001 01 **** 1 01 01 **** | 01
| 1 Appl" 0 12001 01 **** 1 01 01 **** | m|
1171 Subtot RSH Gain=7+8^.+12+161 **** i x*** 1 1644| **** 1 **** | 11261
1181 Duct Btuh Gain 1 0%1 **** | 0| 0%1 **** | 01
1191 Total RSH Rain = 17+18 1 **** | **** 1 16441 **** | **** | 11261
1201 CFM Air Required 1 **** 1 861 881 **** | 481 601
Printout certified by ACCA to meet all requirements of Manual Form J --
Job #: Zone: /-23-1i)5
---^- MANUAL J: 7th Ed. -'-- RICHT J: V1.74 ---- G/N !!!! --- Page 4 - - - -
11 Name of Room | BFDRO2M ��3 |
21 Running Ft. Exposed Wall l 12.0 Ft" |
31 Room Dimensions, Ft. | 12.0 x 14"0 Ft. i x Ft.
41 CeilngsrFt | Condit. Option | 3.0 1 heat/cool 1 i
|_______-___-____~___-_.^.---------------------------|------------------
TYPE OF | |CST| HIM | Area 1 Btuh 1 Area 1 Rtuh
EXPOSURE i INC). iHtg |Clg |Length| Htg | Clg |Leng*h| H+8 | Clg
.______^________~-----------------------------|--------------------|
5i Gross ia|12Di 5.61 1.41 961 **** 1 **** i | **** ****
| Exposed 1b11581 5"21 Q"@| 01 **** 1 **** 1 i **** ****
1 Walls and 1c114C1 5"41 0,81 01 **** 1 **** ( | **** ****
| Partitions 161 1 0,01 0.01 01 l **** 1 { **** ****
1 lel 1 0.01 0.01 N| **** | 1 **** | ****
i [f| 1 0.01 0"01 01 **** 1 **** | **** i ****
|___________--------------------|-----------~--------)-----~--------------|
| 61 Windows \a| 30150"81 | 151 7611 1 | | ****
1 & Glass |h| 80150"81 ** | 01 01 **** 1 | | ****
1 Doors Htg^ |ci 9I152.81 ** 1 01 m( **** | | | ****
| |d| | 0"0| ** ( 01 01 **** | | | ****
| )e| | 0"01 ** i @| Wi **** | ( | ****
j |f| | 0"01 ** | Q: 0i **** | | | ****
i-'-----------------------------|--------------------|-------------------^|
71 Windows | North 123.01 01 01 ****
| ( & Glass 1 NE&NW | 0.01 01 **** 01 ****
| |
Doors Clg. 1 E&W | 0"01 01 **** 01 ****
| |
1SE&SW | 0"01 01 *u** 01 *«**
| |
1 South |38,01 151 **** | 5701 ****
| |
i Horz | 0^01 01 **** | Qi
|---------^----------|--------------------|
|
31 Othr doors |a|10D132.21 8,11 01 01 01
1 |b| | @"@: 0.01 01 01 01 | | |
|--------- ---------------------|--------------------1-------------~-'----|
|
91 Net |a|12D1 5"61 1"41 311 4541 1141
| Exposed 1611581 5.21 0.01 01 01 Q|
|
Walls and 1c114131 5.41 0.81 01 Q| 01
| Partitions |d| 1 @"@| 0"01 01 01 01
| |
lel | 0"01 0.01 0| 01 01
| i |f| 1 0"01 0^01 01 01 01
|-------------------------------|--------- ----------|--------
|1Qi Ceilings |*116H1 1,31 1.01 1681 3061 1661
I | |b| 1 @.m| 0.0| 01 01 01
i i i 0 i 0.01 @"e| W| 01 0|
i---------------------------^---|--- ------------|----- --------|
|11| Floors \a\21A\ 1.71 0.01 m| Q| @|
| | )b! ( Q,Q| 0"01 01 01 01
| | }c} ! 0.01 0.01 @| 01 01
|----------------------------'--i---------- ---------|------------'-------|
1121 infiltration a 172.3111.21 151 10341 1681 { | \
|-------------------------------i--------------------{
-------------------
1131Subtot Dtuh Lsss=6+8."+11+121 **** 1 26041 o*** 1 **** | | ****
1141 Duct [!tuh Loss | 0%1 m| **** i %I | ****
1151 Total 9*uh Loss = 13+14 1 **** 1 26041 **** 1 **** i | ****
|----------- ----------------- |--------------------|--------------------|
1161 Int. Gains: People 0 3001 01 **o* | 01 1 **** � \
|^ | Appl. 0 12001 Q! **** | 01 | **** >
i:1/1 qubtot RSH Gain=7+8..+12+161 **** 1 **** | 10181 **** i ****
1181 Duct Btyh Gain 1 0%1 **** | 0| %| **** |
\|9i,Total RSH Gain = 17+18 i **** | **** i 10181 **** 1 ****
1201 CFM Air Required 1 **** 1 40| 541 **** {
Printout certified by ACCA to meet all requirements of Manual Form J --
MANUAL J: 7th Ed"
'
RIGHT—J: Vl"74 S/N ! ! ! !
RIBHT —J WINDOW DATA
Joh #:
, 7-23-95
.
W S D W G L S S ON A S 0 O W C W S
NR 1 A L O T H V G N H V V H H N H
DWRL A WR A H L G 0 R R G T A A
W i Z E M D 6 Z L. 0 X Y T M R ;',:
BASEMENT
an s a c n n n n 2 90 1"0 @"@ 0.Q 1.0 38"Q 32"0 0"0
a n n a c n n n n 2 90 1.@ 0"0 O.0 1"0 23,0 24"Q 0.0
c n s a c n n n n 2 90 1"0 @"Q @"@ 1.e J8"@ 21"@ Q,0
GREAT ROOM/FOYER
a n s a c n n n n 2 90 1.@ m.0 O. 1"0 33"121 30"0 m"@
c n n n n P 90 1.0 u.0 m.0 1,0 J8.0 21. 0.m
KITCHEN/DINING
a n n a c n n n n P 90 1.0 a.@ 0.0 1"@ 23,@ 10.12:1 0.Q
b n n a c n n 2 50 1^0 0"0 0"@ 1"@ 23"@ 42"0 @.@
MASTER BED/BATH
� n 11 a c fl n n n 2 90 1.m 0.0 @"0 1"@ 23"0 3W.0 @"o
BEDROOM #2
a n s a c n n n n 2 91Z1 1.0 0"0 @"0 1"Q 38"Q 15"@ @"0
BEDROOM #3
a n s a c n n n n 2 90 1.0 @"@ 0.0 1"@ 38.@ 15.@ 0"@
LOTt 114
..SI E R %A dtsTA RANcJk.
Q ro HOME
NOT TO SCALL
•
4o
g'►Sr{N G RoA0
c0HNTy rd,
* 331
14t3. 1 -ii`
ANDERSON COMPONENTS-LINDCAId
101 S. GENEVA RD.
-LINDON, UT 84042
Phone: (801)785-0255 Fax: (801)785-0252
To:
84 LUMBER L8830,3-26
779 22 ROAD
GRAND JUNCTION, CO 81504
DeliveryList
Job No: L8830
Page:
Date: 03-23-1998
Project ID: 18830
Project:PROCTOR Block No:
Model: Lot No:
Contact:
Site:
Office:
Deliver To:
YARD
GRAND JUNCTION, CO 81504
Account No:
Designer: MARK
Salesman: KIM
Quote No:
Name:
Phone:
Fax:
BRUCE
(303) 245-8400
(303) 245-5372
Tentative Delivery Date: 3-31-98
Profile:
Qty:
Truss Id:
Span:
Truss Type:
Slope:
LOH
ROH
Load By:
----(<1 Hh _..
2
A
104 lbs, each
28-0-0
FINK
5.00
0.00
2-0-0
2-0-0
�_
5
Al
84 lbs. each
28-0-0
FINK
5.00
0.00
2-0-0
2-0-0
a_I
__
!28.0-0
910s. each
SCISSOR
5.00
2.50
2-0-0
2-0-0
n
it a 77 / 91-Zad y w y
Z____,..,.- ' i
,7574_r c! .
7
Above listed
to right).
Received
Date:
items have been received in good condition. (exceptions listed
by:
.. -..
Thank You for your Business. .
Job
L8830
Truss
A
Truss Type
FINK
Qty
2
Ply
1
84 LBR GJ 3-26-98 MM
..ne.enn rmmnnnnnre unnnn 3.300
$ Sep Al 1995 MIi1ekInus nes, nc. on Mar 231
N
b
1-0.0
140-0
14-0-0
4X4 =
2
28-0-0
14-0-0
3x4 =
1-0-0
4x4 = 3x4 =
28-0-0
28-0-0
LOADING (psf)
TCLL 40.0
TCDL 10.0
BCLL 0.0
BCDL 10.0
SPACING 2-0-0
Plates Increase 1.15
Lumber Increase 1.15
Rep Stress Incr YES
Code UBC -94
CSI
TC 0.00
BC 0.00
WB 0.00
DEFL (in) (loc) Udell
Vert(LL) 0.00 / `...
Vert(TL) 0.00 /
Horz(TL) 0.00 n/a
Min Length / LL deg = 240
PLATES GRIP
M20(20ga) 149/110
Weight: 104 (lbs)
LUMBER BRACING
TOP CHORD 2 X 4 SPF No.2 TOP CHORD Sheathed
BOT CHORD 2 X 4 SPF No.2 BOT CHORD 3-4:2-0-14, 1-4:2-0-14.
OTHERS 2 X 4 SPF Stud/Std
FORCES
NOTES
1) Gable requires continuous bottom chord bearing.
2) Gable studs spaced at 24 inches on center.
3) Gable studs exceeding 72 inches length to be laterally braced at midpoint. For studs exposed to wind, see MiTek "Standard Gable End Detail".
4) Studs to be fastened with 2x4 M20 plates.
5) This truss has been designed for a 10.0 p.s.f. bottom chord live load nonconcurrent with any other live loads per Table No. 16-9, UBC -94.
LOAD CASE(S) Standard
Job Truss
L8830 Al
Truss Type
FINK
Qty
5
Ply
1
Sep 2U
84 LBR GJ 3-26-98 MM
anderson components, Imdon 4.400 s
19g5-MITeek Industries, n—I c. Mon Marf2712:47:02 1998 Hage 1—
0-a 73-14 14-0-0 20-8-2 26-0-0 29-0.9
In
41-0-0 7-3-14 6-8-2 6-8-2 7-3-14 1-0-0
•
4x4 =
3
5.00 ��
2x40 _ , '_ \\' , 2x40
/
cif 7 1- %---- \�'( \C 4
m.
\ \\ // Z
/ j
r
V
T \
ya
+P
C :'q 8 7 6 `-rf o
.5
T 3x4= 3x4 3x4
= =
5x6 = 5x6 =
9-94 16-3-0 28-0-0
1
9-9-0 8-6-1 9-9-0
Plate Offsets (X,Y): [1:0-2-8,0-0-0), [5:0-2-8,0-0-0]
LOADING (psf)
SPACING 2-0-0
CSI
DEFL (in) (loc) I/defl PLATES GRIP
TCLL 40.0
Plates Increase 1.15
TC 0.92
Vert(LL) 0.35 8/7 937 M20(20ga) 149/110
TCDL 10.0
Lumber Increase 1.15
BC 0.90
Vert(TL) 0.53 1/8 625
BCLL 0.0
Rep Stress Incr YES
WB 0.49
Horz(TL) 0.11 5 n/a
BCDL 10.0
Code UBC -94
Min Length / LL deft = 240 Weight: 64 (lbs)
LUMBER BRACING
TOP CHORD 2 X 4 SPF 1650F 1.5E TOP CHORD Sheathed or 2-3-12 an center puffin spacing.
BOT CHORD 2 X 4 SPF 1650F 1.5E BOT CHORD Rigid ceiling directly applied, or 10-00-00 on center bracing.
WEBS 2 X 4 SPF Stud/Std Except: 5-6:6-3-0, 1-8:6-3-0.
REACTIONS (lbs/size) 1=1753/0-5-8, 5=1753/0-5-8
Max Horz 1=-19(load case 2)
Max Uplift 1=-98(load case 4), 5=-98(laad case 4)
FORCES
TOP CHORD 1-2=-3022, 2-3=-2585, 3-4=-2585, 4-5=-3022
BOT CHORD 5-6=2772, 6-7=1909, 7-8=1909, 1-8=2772
WEBS 2-8=-614, 3-8=812, 3-6=812, 4-6=-614
NOTES
1) This truss has been designed for the wind loads generated by 85.0 m.p.h. winds at 25.0 feet above ground level, using 7.0 p.s.f. top chord dead load and 10.0
p.s.f bottom chord dead load, 100.0 miles from hurricane aceanline, on a category I enclosed building, of dimensions 45.0 by 24.0 with exposure C (ASCE 7-93).
Lumber Increase = 1.33, Plate Increase = 1.33. Both end verticals are exposed.
2) This truss has been designed for a 10.0 p.s.f. bottom chord live load nonconcurrent with any other live loads per Table No. 16-B, UBC -94.
3) SIMPSON H2.5 connectors recommended to connect truss to bearing walls due to uplift as follows: One connector at joint(s) 1, 5.
LOAD CASE(S) Standard ,
Job
L8830
Truss
Truss Type
A2 SCISSOR
anderson components, lindon
co
c1
_ of
Y
4x12,
Qty
Ply
16 1 84 LBR GJ 3-26-98 MM
4.30U s Sep 2U 1993 Mi I ek Industries, Inc. Mon Mar23T2-46TT4 1998 Page 1
5-3-0 9-7-8 14-0-0 18-4-8 22-9-0 28-0-0 29-0-0
5-3-0 4-04 4-44 44-8 4-04 5.3-0 1-0-0
5.00 fit
5x6=
5
avas , 4,---;-: /W��\Ty-3x4
,:.-
------__>.__
3x6;3x4o T2i W2
W2- \
2x4 = = 2x4
2 e
�%a4g 8x125/M18= -e1_-.-- \ 71
12 10
3x4 _.
7.7-9
3x4=
2.50[12
140-0
204-7
28-0-0
7-7-9
84.7
6.4-7
7-7-9
Plate Offsets (X,Y): [1:0-2-0,0-0-12],[5:0-0-0,0.1-8],[9:0-2-0,0-0-12], [11:0-0-0,0-3-4j
LOADING (psf)
SPACING
2-0-0
CSI
DEFL
(in)
(loc) I/deft
PLATES GRIP
TCLL
40.0
Plates Increase
1.15
TC
0.85
Vert(LL)
0.60
11
555
M20(26ga) 149/110
TCDL
10.0
Lumber Increase
1.15
BC
0.75
Vert(TL)
0.89
11
370
M16(16ga) 139/91
BOLL
0.0
Rep Stress Inc[
YES
WB
0.69
Horz(TL)
0.56
9
n/a
BCDL
10.0
Code
UBC -94
Min Length / LL defl = 240
Weight: 89 (lbs)
LUMBER
TOP CHORD 2 X 4 SPF 2100F 1.8E
BOT CHORD 2 X 4 SPF 2100F 1.8E
WEBS 2 X 4 SPF Stud/Std *Except'
W1 2 X 4 SPF No.2
REACTIONS (lbs/size) 1=1753/0-5-8, 9=1752/0-5-8
Max Horz 1=-19(load case 2)
Max Uplift 1=-98(load case 4), 9=-98(load case 4)
BRACING
TOP CHORD Sheathed or 2-0-14 on center purlin spacing.
BOT CHORD 1-12:6-3-0, 11-12:6-3-0, 10-11:6-3-0, 9-10:6-3-0.
FORCES
TOP CHORD 1-2=-6004, 2-3=-5511, 3-4=-5511, 4-5=-4052, 5-6=-4052, 6-7=-5511, 7-8=-5511, 8-9=-6004
BOT CHORD 9-10=5589, 10-11=4884, 11-12=4884, 1-12=5589
WEBS 2-12=-401, 4.12=500, 4-11=1077, 5-11=2670, 6-11=-1077, 6-10=500, 8-10=-401
NOTES
1) This truss has been designed for the wind loads generated by 85.0 m.p.h. winds at 25.0 feet above ground level, using 7.0 p.s.f. lop chord dead load and 10.0
p.s.f bottom chord dead load, 100.0 miles from hurricane oceanline, on a category I enclosed building, of dimensions 45.0 by 24.0 with exposure C (ASCE 7-93).
Lumber Increase = 1.33, Plate Increase = 1.33. Both end verticals are exposed.
2) This truss has been designed for a 10.0 p.s.f. bottom chord live load nonconcurrent with any other live loads per Table No. 16-6, UBC -94.
3) SIMPSON H2.5 connectors recommended to connect truss to bearing walls due to uplift as follows: One connector at joint(s) 1, 9.
LOAD CASE(S) Standard
INSPECTION WILL NOT BE MADE UNLESS I
THIS CARD IS POSTED ON THE JOB
24HOUPS NOTICE REQUIRED FOR INSPECTIONS
HOURS
BUILDING PERMIT
/^ G RFIELD COUNTY, COLORADO /
Date Issue4/3 9 Zoned Area Permit No ✓ 7 /9
AGREEMENT
In consideration of the issuance of this permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location; construction and erection of the proposed
structure for which this permit is granted, and further agrees that if the above said regulations
are not fully complied with in the zoning, location, erection and construction of the above
described structure, the permit may then be revoked by notice from the County Building
Inspe3an I IATELY HICOMENU AND VOID.
(veil Nir
�J4r
Use
Address eptDesc�tin
Owne r
Setbacks Front
DANContractor testy
Side Side Rear
This Card Must Be Posted So It is Plainly Visible From The Street Until Final Inspection.
INSPECTION RECORD
Footing j , r
Foundation ,: /5 v 472-c/3; .4t— . t.: , (3/ `ln) ' C,
Underground Plumbing
Insulation2 -,2E- 9f A,.
Rough Plumbing 22 /s- i tile, ,
Drywall cP -Q2-- A -No_
Chimney & Vent ,,;- p
Electric Final (by State Inspector))/r(c q
Gas Piping c ./3 -9/%w,.,_
Final /e. -•- _, Yd' / ;_:
Electric Rough (By State Inspector) g ,--
- Septic Final 1;
Framing 3Hr;-3.8 kcs.'.c
(To include Root in place and Windows •
and Doors installed).
Notes:
ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING -
WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND.
THIS PERMIT IS NOT TRANSFERABLE! t
Phone 945-8212 109 8th Street County Courthouse Glenwood Springs, Colorado.
I APPROVEDDO NOT DESTROYgTII.IS CARD
Dat �(��L,� By .&414
IF PLACED OUTSIDE -COVER WITH CLEAR PLASTIC