HomeMy WebLinkAboutApplicationRECEl\TEP
SEP 1 7 101~
GARFIELD COUNT'f
MMUNITY OEVELOW E'~T
-
Gar.fie/ti Cmmty
Community Development Department
108 8"' Streat, Suite 401
Glenwood Sprln1s, CO 81601
(970) 945·8212
www.1ad!11d;mnty.mm
TYPE OF CONSTRUCTION
8 Commerclal/Multi-Famlly
0 Manufactured Home (SF or Duplex)
0 Resldenlial (SF, Duplex, or TownhomeJ
1 INVOLVED PARTIES
0 Demolltlon
0 Reroof
Property Owner: Jolley. Richard and Mary Family, LLP Phone: ( __ 1, ______ _
Malllns Address: 1288 Counly Road Road 245 New Castle, CO 81647
Contractor: TPI Industrial, Inc. Phone: L.~_J,_2_43_·_46_4_2 ___ _
Malllns Address: 2471 Riverside Pkwy Unit A Grand Junction, CO 81505
Archltect: _________________ Phone:l __ I _____ _
MalllnsAddress: __________________________ _
Enslneer: CCI Engineering Phone: L ... !~_J_24_S_-o_s_1_1 __ _
Malllns Address: 1129 24 Road Grand JuncUon, CO 81505
Manufactured Homo Installer: ___________ Phone:( __ ) _____ _
Mallln1Address: __________________________ _
PROJECT NAME AND LOCATION
Describe Work: Erect new 24'x44'x20'Pro-englneered building over exlsllng equipment on a well pad.
Job Address: Jolley KP 24·8 Well Ped, S81, CO (see alleched location maps)
Assessor's Parcel Number: 216117200086 Sub. ________ Lot Olock
Owner's Valuation of Work: $_7_o._o_oo _______ Property Size (Sq.Ft or Acres): -----
Sq.Ft of Bulldlng: 1056 Height: 20' #of Floors:,_1 ____ _
Class of Work: 8 New D Alleration 0 Addition 0 Repair 0 Move/Relocation
Garage: OAttached 0 Detached
Septic: 01505 D Community
Type of Heat: 0 Natural Gas 0 Propane 0 Elec:lric D Other
Driveway Permit: 0 EJCempt D Permit n: ______ _
NOTICE
&llluldJlt. This appliutlon for a Pulld ln1 PC!rmlt mull be slaned by the Owner of the property, described ilbove, or
an authorized agent . If the slgn11u1e below 1s nol that of the Owner, a separate leuer of authority, signed by the
O\Yner, must be provided with this llppllcalion.
leral Acc11s. A BuUdlng Permit cannot be lnued without proof of leaal and adequille access to lhe property for
purposes of Inspections by the Building Olvlslon.
Other Pcrml!s. Mulllple sep1rate permits may be required: 111 State Electrical Permll, f2) County ISOS Petmll, (ll
another permit requ11ed for use on the property kfenlifled above, e g. State or County Highway/ Road l\cceu or a
State WaSlewater Ois<harge Permit.
\fold Permit. A Building Permit be<omes null and void If the work authorued Is not commenced within 180 days of
the date of lnuance and if work is suspended at abandoned for ii period of 180days after commencement .
CERTIFICATION
I hereby cer Illy that I have read this Application and that the Information containl?d above ls true and correct I
undetsland lhal !he 8ulldlng Division accepts the Appllc.illon, along with the pl•m and specifications ;ind Olher
data submllled by me or on my behalf (submlttals), based upon my cattlficatlon as to accuracy. Assuming
complelenen of lhe submlltills and approval of this l\ppllcatlon, a Building Permll will ba Issued granting
permission to me, as owner, to construct the structure(s) and f.;icllith:s detailed on the su bmlllals reviewed by the
Building Division. In conskfer.tlon of the Issuance of the Building PC!rmll, I agree th1t I and my agents will comply
wUh p1ovlr.lons or any federal, stale or local law regulating the work ind the Garfield County Building Code, ISDS
regula lions and appliCilble land use regul;lllons (County Regula!lon(s)). I acknowledae that the Building Per mil
may be suspended or revoked, upon notice lrom the County, 1r the location, construction or use of the s11ucture(s)
and fildlily(les), described .;ibove, are not In compliance with County Regulallon(s) or any other applicable law .
I h~reby grant permission lo the BuUdln1Division10 enter the property, described above, 10 inspect the work . I
rurther ilcknowledge lhat the Issuance of the Buildln.i: Pern111 does not prevent the Bu ildtn1 Official from : (l)
requiring the correction of errors in lhe submlttals, 11 any, discovered after luu111ce; or 121 stoppina construcUon
or use of the structure(s) or faclllty(les) If such IS In violation of County R!!gulallon(s) or any other applicable law.
Review of this Application, Including submiltillS, .and lnspecllons of the work by the Building Oivlslon do not
constitute an acceptance or responslblllly or liablllty by the County of errors, omiHlonr. or discrepancies. As the
Owner, I acknowledge that responslblhty for ccmpll.ance with faderal, state and loc•l l.aws and County Regulations
rest with me and my authorlied agents, lncludln& without limltatlon my ilrthltett deslsner, engineer ilnd/ or
builder.
I herebv acknowledge that I have read and understand the Not
have provided the required lnform;itlon whl
nd Certlflcallon above a1 well as
e to the beu of mv knowled1a.
.~k~,_-
*~~~_.a~~...L:;~fld_~~'J/&11
Propertv Owner Print and Sien
OFFICIAL USE ONLY
Spe,111 Condlllons:
I ... ..
Zonli•1: 1<
Building Plan Review
Description of Work: erect new 24'x44'x20' pre-engineered buidling over existing equipme
Bin#:
Location Address: Sec 17, T06, R91
SILT,CO 81652
Case Manager: David Bartholomew
Plan Case Number: BLDG-9-14-8077
Parcel: 218117200086
Application Date : 09/17/2014
Building
___ / ___ Engineered Foundation
_ ___./0 ...... ~_tf __ Oriveway Permit
__ .. / ___ Surveyed Site Plan
~~-!VJ .. f _;,_.,_.Septic Permit and Setbacks
__ ... / ___ Grade/Topography 30%
_ ___.fVt-~._.A..___Attach Residential Plan Review List
_____ Minimum Application Questionnare
~~-4'----Subdivision Plat Notes
___ / ___ Fire Department Review
/ _____ Valuation Determination/Fees
/
-----Red Line Plans/Stamps/Sticker
__ / ___ .Attach Conditions
__ / ___ _,Application Signed
/ _____ Plan Reviewer To Sign Application
/ _____ Parcel/Schedule No.
__ M_j_A __ 40# Snowload Letter -Manu. Homes
_____ Soils Report
Thursday, March 5, 2015
Contacts
Owner: Jolley, Richard & Mary Familly LLLP
Applicant: Jolley, Richard & Mary Familly LLLP
Applicant Phone: 379-6669 Email:
Planning/Zoning
I
Property Line Setbacks
/ 30ft Stream Setbacks
/ Flood Plain
/ Building height
/ Zoning Sign-off
tf A Road Impact Fees
11" HOA/ORC Approval
/ Grade/Topography 40%
/,
7 Planning Issues
Subdivision Plat
General Comments:
NOTE: I( any required lnrormalion is missing. delays in issuing the permit are to be expected. I(
determined by the Building Official that addi!lonal information Is necessary to review the application
and/or plans for compliance , the appllca lion may be placed on hold until the required Information is
provided . Work may not proceed without lhe Issuance or a permll.
The Bu ilding Division will collect a Plan Review fee at lime of appllcallon submillal. The Perm it Fee. as
well as any Septic or Road Impact fees will be collected when the permit Is issued.
The permit application must be signed by the o\mer or by a person having written authority from the
owner to act as their representative.
I heroby acknowledge I havo read, understand, an wlll abldo with tho requirements of thla
checkllst.
ce-Garfield County
Community Development Department
108 8th Street, Suite 401
Glenwood Springs, CO 81601
(970) 945-8212
www.garfield-county.com
COMMERCIAL OR
MULTI-FAMILY
BUILDING PERMIT
APPLICATION CHECKLIST
COMMERCIAL OR MULTI-FAMILY BUILDING PERMIT APPLICATION CHECKLIST
In order to understand the scope of work intended and to expedite the issuance of a permit, it is
important that complete information be provided. Please review this document to determine if you have
adequate information to design your project and to facilitate a plan review.
APPLICATION FORM: Please make sure the following information is provided on the application .
• Parcel number obtained from the County Assessor's Office.
• Job address (assigned physical address).
• Legal Description: lot, block, filing, subdivision or tract, section, township and range.
• Owners name, mailing address, phone, fax, or cell.
• Contactors name, mailing address, phone, fax, or cell.
• Architect/Engineer's name, mailing address, phone, fax or cell.
• Building size, height, number of stories, lot size.
• Use of building (commercial)
• Class of Work (new, addition, alteration, repair, demo, move, other)
• Description of work.
• Type of heating (natural gas, propane, electric, other)
• Sewer system (Community or ISDS), also see other items below.
• Garage (attached or detached)
• Driveway permit (please see other items below)
• Valuation (labor and materials)
OTHER ITEMS:
• If you anticipate obtaining a water-tap from the City of Rifle, please provide a letter indicating that
the City will provide water service. (Required to submit building permit application).
• ISDS requires a septic permit application to be submitted with the building permit application.
• A separate electrical permit must be obtained from the State of Colorado Electrical Board.
• At the time of building permit submittal, you are required to show proof of legal and adequate
access to the site. This may include proof of right to use a private easement, County Road &
Bridge permit, or Colorado Department of Highway permit, including a Notice to Proceed. The
County Road & Bridge Department can be reached at 970-625-8601 .
• If you anticipate excavating or grading prior to issuance of a building permit, you will be required
to obtain a separate grading permit.
• If you belong to a Homeowners Association, it is your responsibility to obtain written approval, if
required.
• Provide copies of any Resolutions and/or Land Use Permits associated with this property.
• Projects with more than 1 O occupants require plans sealed by a Colorado Licensed Design
Professional. Occupantload shall be calculated by JBC Table 1004.1.1.
• A Colorado State Licensed Electrician and Plumber must perform installation and hook-ups.
BUILDING PLANS: 2 sets of plans must be submitted. Plans must be 18nx24" minimum size, complete,
identical, legible, and to scale. Certain projects may also require a third copy of the plans be submitted to
the local Fire District for review prior to permit issuance. All plans will be checked at the counter for
completeness. If any of the required information is missing, the building permit application cannot be
accepted.
SITE PLAN: Please make sure the following information is provided on the site plan.
• Property address/legal description.
• North Arrow and Scale on each page.
• Show all property lines, building envelopes, flood plain, and easements.
• Provide setback distances from boundaries, buildings, septic, well, and waterways.
• Location and direction of the county or private road and driveway accessing the property.
• Proposed and existing structures include sheds, barns, decks, patios, and any other buildings.
• Existing and proposed grade, positive drainage around structure (to be contained on site).
• Streams, rivers, creeks, springs, ponds and ditches.
• Existing and proposed wells, septic tanks, leach fields, and other systems. (if applicable)
• Retaining walls (engineer stamped detail required for walls over 4 ft, measured from bottom of
footing to top of wall).
NOTE: Any site plan depicting the placement of any portion of the structure within 50 feet of a property
line or not within an established building envelope shall be prepared, stamped, and signed by a licensed
surveyor. For structures to be built within a building envelope, provide a copy of the recorded subdivision
final plat with the proposed structure located in the building envelope.
COVER SHEET:
• Project identification.
• Project address and/or legal description .
• Design specifications to include building use and occupancy classification, type of construction,
building height and area calculations, occupant load, and fire sprinkler systems.
ARCHITECTURAL PLANS: Please provide the following information on the architectural plans.
• Per C.R.S. 12-4-112; Structures designed with an occupant load exceeding 10 require Colorado
State Licensed Design Professional stamped plans.
• Minimum 4 elevations (N,S,E,W)
• Floor plans for each level including dimensions and scale noted.
• Clearly label each room or space (office, storage, mechanical, elevator, etc).
• Wall types; clearly labeled and referenced. Identify all fire resistive wall construction.
• Construction details for all fire resistive elements referenced on floor plans and cross sections.
Include wall, floor/ceiling, roof/ceiling, shaft wall assemblies, and structural frame. Provide the fire
resistive listing number referenced on each assembly detail. (ex. UL P123)
• Window & door sizes, types, and operation and direction of swing noted on the floor plan.
• Specify roof slope/pitch, roof covering, and siding materials.
• Energy design specifications/details for R-values, LI-factors, and SHGC's per IECC.
• Stair and guard details specifying rise, run, height and spacing.
• Accessibility; show compliance with accessibility requirements for all elements of the building per
IBC, Chapter 11 and ICC/ANSI A 117.1, ADA, FHA, and UFAS.
STRUCTURAL PLANS: Please provide the following information on the structural plans.
• Per C.R.S. 12-4-112; Structures designed with an occupant load exceeding 10 require Colorado
State Licensed Engineer stamped plans.
• Engineered foundation design per soils report. Geotechnical report referenced.
• Design specifications to include roof and deck snow load, wind and seismic design, frost depth.
• Foundation plan showing complete footing and foundation dimensions.
• Footing and foundation details specifying reinforcement referenced on plans.
• Framing plans for each floor level and roof. All beams, columns, joists, rafters, trusses and all
live/dead loads specified.
• Framing /connection details referenced on plans.
• Pre-manufactured structures require an engineers stamp, signature, and date.
MECHANICAL PLANS: Please provide the following information on the mechanical plans.
• Per C.R.S. 12-4-112; Structures designed with an occupant load exceeding 10 require Colorado
State Licensed Engineer stamped plans.
• Energy design calculations and details verifying compliance with the 2009 IECC.
• Floor plans for each level showing size, location and materials of all ductwork, plenums, return
and outside air intake registers.
• Size and location of all combustion air ductwork and openings.
• Size, type and termination of all gas appliance flues and vents.
• Location of all fire and combination smoke/fire dampers.
• Equipment schedule for all mechanical equipment (boiler, furnace, exhaust fans, etc).
• Commercial kitchen hood location, hood and duct sizes, CFM calculations.
PLUMBING PLANS: Please provide the following information on the plumbing plans.
• Per C.R.S. 12-4-112; Structures designed with an occupant load exceeding 10 require Colorado
State Licensed Engineer stamped plans.
• Floor plans for each level showing DWV layout and sizing, materials, slope and sewer location.
• Water piping materials, length and size of pipe, water meter location, fixture unit demands,
location and type of backflow prevention devices.
• Gas piping materials, length and size of pipe, gas meter location, and BTU/hour demands.
• Additional piping plans for roof/deck drains, condensate, medical gas, etc.
• Plumbing fixture schedule for all plumbing equipment.
• Commercial kitchen plumbing fixtures, food preparation equipment, grease interceptors, etc.
ELECTRICAL PLANS: Please provide the following information on the electrical plans.
• Per C.R.S. 12-4-112; Structures designed with an occupant load exceeding 10 require Colorado
State Licensed Engineer stamped plans.
• Floor plans for each level showing location of lighting fixtures, switches, receptacles, emergency
exit signs and lighting, and panel location.
• Diagram showing service entrance, conduit/wire size, main disconnect size, grounding
electrode/conductor size, feeder conduit/wire size, transformers and generators.
• Panel schedule showing bus/breaker sizes, circuit description, voltage, phase, amperage, etc.