REVISED INDIVIDUAL SEWAGE DISPOSAL SYSTEM DESIGN
(Originally Submitted 10/19/2008)
(Revised for Well Setback 12/17/2008)
January 9, 2009
Prepared by: Thomas A. Cronk, P .E.
Cronk Construction Inc.
1129-24-Road
Type of Design:
Client:
Property address:
Grand Junction, CO 81505
245-0577
Commercial Repair System
Kent Cotten
KC Equipment
30585 Hwy92
Hotchkiss, CO 81419
970-250-3471
Lot 1, Big R Commercial Park, Hwy 6, CR 221, CR 223, Rifle, CO 81650
1 Tax schedule No .:
~
]
J
J
Legal Dcscript:
Page 1 of 10
J
l
l
J
J
J
J
..J
1.0 Site History
As shown on the attached plot plan, the site consists of approximately 8.93 acres of uncultivated native
soil. Drainage is approximately 1 % to the southwest. The site is a commercial property on which six
commercial office/warehouse structures have been built. Three of the existing structures (units 2-3, 5,
and 6) each have their own onsite wastewater treabnent systems (OWTS) and two of the existing
structures (units 1 and 4) share a common OWTS. Unit 7 is currently an open warehouse with no water
service or plumbing fixtures . Sewage loadings at the site are generated from Vi bath facilities associated
with the office/warehouse units. No floor drains or additional sewage loadings discharge to the
OWTS(s). The existing OWTS(s) on the property are failing . The owners wish to convert unit 7 into an
office/warehouse configuration with sewer service and also wish to install a common repair OWTS to
serve all of the buildings on the site.
A percolation test/soils evaluation was conducted on the property ofreference on 07/14/08 by Tom A.
Cronk, registered professional engineer (R.P.E.). The 07/14/08 investigation was intended to develop
subsurface design parameters for a repair ISDS to serve the existing commercial buildings. Because of
the commercial nature and size of the project, an engineered ISDS design has been prepared. The
07/14/08 perc test/soils evaluation is attached for reference as Append ix A. The locations of the site
investigation excavations are shown on the attached plot plan. A discussion of developed subsurface
design parameters and the engineered ISDS design follows .
2.0 Development of Design Parameters
Aperc excavation trench (excavation A) was extended to a depth of 120" below ground surface (BGS).
There was no evidence of ground water or high seasonal water table in the open excavation to a depth of
120" BGS. The soils evaluation indicates three distinct soil horizons underlie the site . A lithological
description follows:
depth (in.)
0 11 -811
8" -96"
96" -120"
description
1-1/211 pitrun manfill
sandy clay/clayey sand, tan; hard; friable
clayey sand, tan
...1 The OWTS will consist of a recirculating packed bed textile filter treatment system and a pressurized
gravel trench absorption field. An average design perc rate of 5 8 min/in. is chosen for overall system
sizing for subsurface absorption below a depth of 48" BGS .
....
J
Page 2of10
.....
..,
l
J
3.0 System Design
The existing OWTS(s) currently serving the structures on the property shall be abandoned.
Abandonment of the absorption fields shall consist of capping the influent piping followed by
abandoning the absorption fields in-place. The existing septic tanks shall be drained of residual fluids by
pumping and physically removed . Five 2,000 gallon concrete, two compartment septic tanks will be used
for primary treatment of sewage. As shown on the attached septic layout plan, the new septic tanks will
be placed in the same area as the existing septic tanks to facilitate easy hookup to existing plumbing. A
new 2000 gallon septic tank will be added to building unit 7 to facilitate the addition of plumbing fixtures
and conversion into an office/warehouse rental.
Duplex septic tank effluent pumps (STEP) will be placed in the second compartment of each septic tank
to de1iver septage to a secondary treatment unit. Each STEP system will deliver scptage to a common
pressure main. As shown on the attached graphics, the STEP pump will consist of duplex Orenco pumps
(model no. PF200512) configured in an Orenco pump vault (model no. PVU57-2419-L). Each STEP unit
will be fitted with a 1-1/4" discharge assembly and a 1-1/4" check valve installed below the frost line to
prevent backflow from the 4 11 common pressure main (see detail). A 2-112" pressure transport line
(SCHD 40) will be used to convey septage from the STEP unit to the common pressure main . The 2-112"
pressure line must be installed below a depth of 36 11 or insulated to prevent freezing.
As shown on the attached graphic, the common pressure main will consist of 4" SCHD 40 PVC and shall
transport septage to the packed bed textile filter secondary treatment unit. The pressure main will be
installed below a depth of 36" or insulated to prevent freezing. All sewage lines shall be encased with
SCHD 40 PVC piping with water-tight end caps a minimum of 10 1 to either side of all domestic waterline
crossings.
The secondary treatment unit will consist of a 3,000 gallon concrete recirculation tank connected to an
AdvanTex AXIOO packed bed textile filter treatment system. As shown in the attached graphic, septage
will be transferred from the recirculation tank to the AXlOO unit by a Orenco duplex pumping system
(model no . PF500512) configured in an Orenco pump vault (model no . PVU72-2419-L). Treated
wastewater from the AXlOO will be returned to a recirculation valve (Orenco model no. MM4U) where it
well be directed back to the recirculation tank or to final discharge. An Orenco control panel with
remote telemetry capability will control all aspects of the treatment process.
A 1,250 gallon concrete will be used as a lift station for discharge of treated effluent to the absorption
field. The lift station will be configured with a duplex Orenco pump (model no . PF500512) setup in an
Orenco pump vault (model no. PVU57-24-19-L). As shown in the attached graphics, two 2-112" SCHD
40 pressure mains (one connected to each pump of the duplex pumping system) will transfer treated
effluent to the absorption area. The pressure mains will be self draining or be buried a minimum of 36 11
below ground surface to prevent freezing .
A trench absorption field is proposed for discharge of septic effluent at the site. As shown in the
attached graphics, the absorption field will consist of eight trenches 31 wide and ranging in length from
1421 to 16' as shown on the attached graphic. The trenches will be excavated to a depth of 72". After
excavation, 42 11 of gravel fill (1.0"-2.5" screened rock with aggregate components of uniform size) will
be used to construct a level seepage bed in each trench. Adjacent trenches shall be separated by a
horizontal distance of 6' of undisturbed soil. The absorption field dimensions shown on the attached
Absorption Field -Plan View (i.e., trench length, separation , trench width, overall field size, etc .) must
Page 3 oflO
J
J
be maintained to achieve the required setbacks shown on the attached Septic Layout Plan.
Septic effluent distribution piping in the absorption field will consist of a 4" perforated discharge line
placed level (end-to-end) down the center of each trench. As shown in the attached graphic, the
perforated line will terminate 18" from the ends of each trench. The perforated line will be embedded in
the gravel seepage fill with a minimum of 36 11 of gravel under, and 211 of gravel over each pipe.
Septic effluent will be introduced into the 4" perforated discharge line through pressurized distnoution
laterals installed in each trench as shown in the attached graphics. The injection laterals will consist of
2" Schd 40 PVC pipe with 1/4" (0.25 11
) holes equally spaced 60 11 o.c. along each trench. Holes in the
injection laterals will be drilled at 12:00 o'clock to direct effluent up for dispersal against the top of the
411 perforated discharge lines. Septic effluent will be delivered to the distribution laterals through two 2"
(Schd 40 PVC) pressure manifold. Each pressure manifold will be centrally located in the absorption
field as shown on the attached absorption field plan view. All pressure piping and absorption field
construction shall be completed in accordance with the attached graphics and as per manufacturer's
recommendations.
Native soil will be used to fill the remaining 30" of trench excavation and construct a soil cap over the
absorption field. Before placing the soil cap, synthetic filter fabric ("myrafi", 140-200 mesh), hay, or
untreated building paper will be placed over the gravel bed to prevent intrusion of fine soils. The native
soil backfill will be mounded 5% over each trench to promote surface flow runoff in the vicinity of the
absorption system.
As shown on the attached Septic Layout Plan, the absorption area is located on Lot 10 of the Big R
Commercial Park Subdivision. In order to construct the absorption area on an adjoining lot, the owner
must execute a legally binding and properly recorded agreement among all affected parties clearly
specifying the permanent nature of the OWTS and limiting future use and construction of any
infrastructure in the affected area which may adversely affect the functioning of, or constitute a violation
of any regulations relevant to the OWTS.
As mentioned above, the AdvanTex treatment system will be controlled with a control panel with remote
telemetry capability. A dedicated telephone line must be provided to the control panel to provide the
remote telemetry capability. Additionally, a frost free water tap must be available within 50' (1 O' min .
setback required) of the treatment system for maintenance and cleaning. Finally, the secondary treatment
system must be installed and maintained by trained personnel to assure effective operation. As the
treatment system manufacturer, Orenco Systems Inc. requires the system owner acknowledge these
requirements by signing a "System Owner's Disclosure" before the treatment system is installed. A copy
of the "System Owner's Disclosure" is attached as Appendix B.
The installer must also confirm the setbacks from property lines, building envelopes, and existing
easements shown in the attached graphics are maintained. Construction of the absorption area will
required the existing well on Lot 10 be sealed and abandoned and moved to the north a minimum
distance of 220' from the absorption area. Abandonment and sealing of the Lot 10 well shall be
completed by a licensed well driller with an affidavit of work being recorded with the Colorado
Department of Water Resources. Additionally, any unknown utility lines, easements, or other adverse
conditions disclosed during construction must maintain the required setbacks listed on page 6 of this
document. A minimum of 12" (18 11 recommended) of soil cover is required for all gravity flow effluent
piping, the septic tank/lift station, and the absorption field (excepting maximum 811 soil cover over septic
Page 4of10
J
J
l
J
_,
access ports). All non-draining pressure effluent piping must be covered with a minimum of 36" of cover
or insulated to prevent freezing.
The existing off-site well (permit no. 170888 as shown on the attacked plot plan) will be slightly more
than 220' from the proposed OWTS absorption area. To afford compliance with required drinking water
well setbacks, the repair OWTS will be limited to a maximum average sewage loading of 1,640 gal/day
(2,460 gal/day design flow). Sewage loadings for the existing buildings are generated from Yi bath
facilities (i .e., stool and lavatory) for employees for one eight hour shift per day. Under a sewage loading
rate of 20 gallons/employee-day-8hr. shift, the 1,640 gallons/day average design rate equates to a total of
82 employees for all buildings at the site. Each individual building will be limited to a maximum of 25
employees to assure that the 2,000 gallon septic tank and STEP system associated with each building can
provide a minimum of 2 day retention time for sewage.
The site currently employs 68 people with a maximum of20 people being employed in a single building.
The design criteria discussed above is thus in excess of current loading rates and will assure the
effectiveness of the OWTS and allow for future expansion.
As discussed above, an gravel trench absorption field is proposed to discharge septic effluent to the
underlying sub-soils. The absorption field will be sized to accept a maximum of 1,640 gallons/day
(average flow) of septage. As shown in the attached graphics, the absorption field will consist of eight
trenches, each 3 ft wide, 72 in. deep, and varying from 142 ft to 16 ft long . The trenches will be filled
with 42" of gravel to provide an effective infiltration area of 3, 792 square feet. Calculations and design
parameters used to size the absorption field follow.
Page 5of10
J
J
.....J
l
J
.J
DESIGN CALCULATIONS
AVERAGE DESIGN FLOW OF 1640 GAL.IDAY
PEAK FLOW = 150% OF AVERAGE == 2460 GAL.IDAY
DESIGN PERCOLATION RATE = 58.0 MIN.IINCH
A• Q{t WHERE
5 ' '
A = ABSORPTION FJELD AREA
Q = PEAK FLOW
t = PERC TIME/INCH
A = 2460 Jss.o = 3746.96 SQUARE FEET
5
UNADJUSTED TRENCH LENGTH= DESIGN AREA = 3746 ·96 = 1248.99
TRENCH WIDTH 3
ADJUSTED TRENCH LENGTH = UNADJUSTED TRENCH LENGTH X ( W + 2 ) , JO
W+ 1 +2(D) 1
WHERE,
W = WIDTH OF TRENCH (FT.)
D =DEPTH OF TRENCH BELOW PIPE (FT.)
ADJUSTED TRENCH LENGTH = 1248.99 X ( 3 + 2 ) = 624.501
3+1 +2(3.0) -~
DESIGN TRENCH LENGTH = 8 TRENCHES WITH CUMULATIVE LENGTH OF 6321
Page 6of10
J
J
J
J
J
J
4.0 Site Specific Installation/Operation Reguirements
The owner and system contractor shall be aware and comply with the following installation and system
operation requirements.
4.1 Installation -Setbacks. Notifications. and Inspections
• All installation activities shall be conducted in accordance with current Colorado
Department of Health ISDSRegu/ations as well as any relevant Garfield County
regulations and requirements . If at any time dµrjng construction. subsurface site
conditions are encountered which differ from the design parameters developed in Section
2.0. construction activities will stop and the design engineer will be contacted to address
any necessary design modifications.
•
•
Installation procedures including grade, location, setbacks, septic tank size, and
absorption field size shall conform with the attached graphic details. Construction
activities and system components will not encroach upon existing easements or utility
corridors. A minimum of 6 ft of undisturbed soil shall be maintained between individual
absorption elements and the septic tank and/or adjacent absorption elements. Minimum
site specific setbacks for system components are:
Source Septic Tanlc
waterline 10'
domestic well 50'
dwelling 5'
property lines 1 O'
dry gulch 10'
pond/lake/stream 50'
irrigation ditch
open
lined/gated
solid pipe
50'
10'
10'
Absorntion Field
25'
220'
20'
10'
145'
170'
170'
10'
10'
Building Sewer
10'
SO'
To avoid surface flow infiltration and saturation of the new absorption system,
abandonment of irrigation in the vicinity of the disposal system is required. Diversion
ditches necessary to divert surface flows around the new absorption bed must maintain
the minimum setbacks listed above.
• All gravity flow sewer lines and effluent distribution piping shall be 4 inches in diameter
and have glued joints. All lines discharging sewage from the residence to the septic tank
shall maintain fall of between 118 in. and 1/4 in. per foot and shall employ sweep 90's or
2-45's at all turns. Sewer lines from the dwelling to the septic tank and at least 6 ft from
the septic tank outlet must meet minimum standard ASTM-3034. Sewer lines under
driveways shall always meet minimum Schedule 40 PVC standards and shall be encased
with corrugated metal pipe or flow fill and minimum 1-112" high density blue board
when covered with less than 24" of soil .
• A minimum of 12" of soil cover (18" reconunended) shall be maintained over all gravity
draining ISDS components to prevent freezing of septic effluent (excepting maximum 811
Page 7of10
J
J
J
J
I
..J
J
cover over septic access ports). Four in . sanitary clean-outs shall be installed at
maximum 100' intervals in all gravity flow effluent lines exceeding 100' in length.
• The installer shall not place gravel in the open excavation until inspected and approved
by the design engineer. AdditionalJy, the final cover shall not be placed on sewer lines,
septic tank, or the absorption area until the system has been inspected and approved by
the design engineer and the Garfield County Health Department. The installer shall
provide 48 hour notice for all required inspections.
• All pressure piping shall be min. Schd 40 PVC and have glued joints.
• The septic effluent pumping system limit switching shall consist of: I) low level/pump
off, 2) high level/pump on, and 3) high level alarm/system failure. The high level alann
shall be easily detectable by occupants. Emergency notification information (e.g.,
telephone numbers of owner, Garfield County Environmental Health Department, service
personnel) shall be posted near the high level alarm.
• All access manholes on septic tanks and dosing chambers will be child proof and contain
appropriate warning labels if accessible to the public . Confined space entry precautions
should be observed by maintenance personnel.
• The surface cap shall consist of sandy loam soil mounded 5% over the absorption field to
promote surface runoff.
• The owner shall execute a legally binding and properly recorded agreement among all
affected parties clearly specifying the permanent nature of the OWTS construction on
Lot 10 and limiting future use and construction of any infrastructure in the affected area
which may adversely affect the functioning of, or constitute a violation of any
regulations relevant to the OWTS.
• Abandonment and sealing of the Lot 10 well shall be completed by a licensed well driller
with an affidavit of work being recorded with the Colorado Department of Water
Resources.
• The system contractor shall be aware of the potential for construction activities to reduce
soil permeabilities at the site through compaction, smearing, and shearing. The
following precautions and construction procedures should be employed during
installation to minimize disturbance to native soils:
i.
ii.
iii.
Excavation should proceed only when the moisture content of the soil is below
the plastic limit. If a sample of soil forms a rope instead of crumbling when
rolled between the hands it is too wet and should be allowed to dry before
excavation continues.
Excavation and backfill equipment should work from the surface where at aU
practical to avoid compaction of the soils at depth .
The bottom and sidewalls of the excavation should be left with a rough, open
surface. The appearance should be that of broken or ripped soil as opposed to a
sheared, smeared, or troweled surface. Any smoothed or smeared surfaces
Page 8of10
l
J
J
J
l
J
J
J
J
1
...J
J
iv.
should be removed with a toothed rake or shallow ripper taking care to remove
loose residues from the bottom of the excavation by hand if necessary.
Care should be taken in placing fill materials in the excavation to avoid
damaging the exposed soil surfaces.
4.2 Operation -Maintenance and Insoections
•
•
•
•
•
The owner shall install a structural barrier if necessary and take precautions to prevent
vehicular traffic, excessive surface watering, accidental flooding, or other activities in
the vicinity of the absorption field which may compact, saturate, or otherwise alter the
subsurface soil parameters used in designing the septic system.
The owner will plant and maintain grass or other shallow rooted cover crop to prevent
erosion and promote evapotranspiration over the absorption field .
The owner will inspect and maintain the required mound ing and drainage away from the
absorption field to prevent saturation from precipitation and surface flows .
To mitigate the generation of preferential flow channels which may compromise the
operation of the system, the owner will inspect and prevent intrusion of burrowing
an imals and deep rooted plants into the absorption field.
The owner shall execute a "System Owner's Disclosure" (see Append ix B) with the
manufacturer of the treatment system to assure the secondary treatment components of
the OWTS are installed and maintained on a regular basis by trained personnel to assure
effective operation.
Page 9of10
...,
l
J
J
J
l
J
l
I
J
,
_J
J
....
I
_J
l
J
5.0 Limitations
This report is a site specific design for installation of an individual sewage disposal system and is
applicable only for the client for whom our work was performed. Use of this report under other
circumstances is not an appropriate application of this document. This report is a product of Cronk
Construction Incorporated and is to be taken in its entirety. Excerpts from this report may be taken out of
context and may not convey the true intent of the report. It is the owner's and owner's agents
responsibility to read this report and become familiar with the recommendations and design guidelines
contained herein.
The recommendations and design guidelines outlined in this report are based on: 1) the proposed site
development and plot plan as furnished to Cronk Construction Incorporated by the client, and 2) the site
conditions disclosed at the specific time of the site investigation of reference. Cronk Construction
Incorporated assumes no liability for the accuracy or completeness of information furnished by the client.
Site conditions are subject to external environmental effects and may change over time. Use of this plan
under different site conditions is inappropriate . If it becomes apparent that current site conditions vary
from those anticipated, the design engineer should be contacted to develop any required design
modifications . Cronk Construction Incorporated is not responsible and accepts no liability for any
variation in assumed design parameters.
Cronk Construction Incorporated represents this report has been prepared within the limits prescribed by
the owner and in accordance with the current accepted practice of the civil engineering profession in the
area . No warranty or representation either expressed or implied is included or intended in this report or
in any of our contracts.
Thomas A. Cronk, P.E.
:ti,,a ,f! ~
Date~'-J 4
1
Zv-.:>"I
NOTE: This individual sewage disposal plan is meant to include the following six pages of
graphics including: 1) plot plan, 2) septic layout plan, 3) absorption field plan view, 4) absorption
field cross section, S) cross section -septic tank and STEP system, 6) cross section • AXlOO
treatment pod and recirculation tank, 7) cross section -lift station, and 8) effluent pumping system
design. The plan is not to be implemented in the absence of these related graphics. In addition,
results from the percolation test and soils evaluation and a "System Owner's Disclosure" are
included for reference as Appendices A and B respectively .
Page 10of10
L L
t.5', typ.
;a
L-.J L J L_ L___; L _J l-L_J l -J L-....J
~---2• SCHD 40 PVC I distribution 111 terals with
1/4• holes spoced 60• O.C. 2• SCHD 40 PVC solid pressure and encased In 4• SCHD 40
laterol piping connecting 11dJ11cent perforoted PVC droln field
distribution lllterols 11s shown · pipe, typ. two <2> of' sixteen
~--------1142''-------~
L J J ~ J
typ -=Jl _J_
T
ri. >. ...
I 25''-----~ ;.,
,18', typ.--1
"'3>Z..2-
2-112· SCHD 40 pressure
tronsport lines
<2 e11ch>
septic Influent frol"I
lift sta. tlon utilizing
duplex pul'\ps <one
line frOl'I each pUl"lp>
2• SCHD 40 PVC solid pressure
loterol piping connecting adjGcent
~ dls-t,.!lo•dlon loter11ls os shown
'------provide ii'
11t ellch end of: llbsorptlon
<see detoll>
perforated section
of piping, 1.5' Fron
each end of trench,
typ.
2• SCHD 40
pressure Manifolds
<two t-ach>
I lllIE I ABSORPTION AREA Dlt£NSIONS SHJ'w'N
HUST BE HAJHTAitf'.D CLOSELY DURING
CQNSIRUCDQN TD ASSIEE SETBACKS
SH!!llH QN SEPTIC umm f'LAN ABE
CAPABLE Qf BEJNG HAINJAINED
ABSORPTION FIELD -PLAN VIEW
SCALE: 1 "=20•
BIG R CDHHERCIAL PARK, LDT
HWY 6, CR 221, AND CR223
RIF"LE, ca 81650
ABSORPTION FIELD PLAN VIE\/
JANUARY 9, 2009
SCALE• t •=20•
'l
1
J
J
J
...J
J
J
J
J
son cop CMOund 51.>
nntlve soil bnckflll
synthetic filter Fnbrlc, hny, or·---
untrented building poper over grnvel
2• SCHD 40 PVC pressure distribution ---S~M:;;HoR
lnternls with 1/4' holes spoced 60' D.C.
nnd encnsed In 4• SCHD 40 perforoted
•xlstlng ground surfnce
PVC drnln Field pipe -1/4• holes to be
directed up nt 12•00 o'clock For dispersion
oF 41ffluent ngolnst top of 4• perforClted ~ drcln Field pipe, typ.
36'x42• grnvel seepnge trench f--36' I /
6' TYP.----l
c1.o·-2.s• wnshed rock> '_)
2' SCHD 40 PVC / provide l'lln. 36' cover
pressur• 1'14nlfo\d for Cltl pressure trClnsport
Unes contolnlng reslduol
2-112• SCHD 40 PVC pressure eff'lent, typ.
tronsport line FroM lift sto tlon
utilizing duplex purlpS Ctyp. one
of two>
ABSORPTION TRENCH -CROSS SECTION <TYPICAL T\v'O OF' EIGHT>
SCALE• l'=S'
BIG R COMMERCIAL PARK, LOT I
BICi R COMMERCIAL PARK
HWY 6, CR 221, CR 223
SOILS LOG NOTES
111 -1-1/2' PITRUN HANF'lll
•2
-96'
ltJ
-120·
SOILS LOG
<SEE NOTES>
RIF'LE, CO 81650
ABSORPTION F'IELD CROSS SECTION
JANUARY 9, 2009
112 -TAN SANDY CLAY/CLAYEY SAND, HARD AND FRIABLE
113 -TAN CLAYEY SAND
2' SCHD 40 PVC press1.1re
to.terol with 114• holes
spoc:ed 60' o.c. o.nc:I c:lrntec:I
up o.t 12•00 o'clock to
direct c:llschclrge up For
c:llspersol ogo.lnst top of
4• perforo.tec:I c:lroln field
pipe, typ.
ND CiRDUND \JATER OR HICiH SEASONAL WATER
TABLE TO 120' BGS
4• SCHD 40 PVC
vent/Inspection
port----
enc:cse pr•ssure \o.·bro.ls with 4'
SCHD 40 p•rforoted PVC droln
Flotlcl pipe with dro.ln holes set
o. t o.pprox. 5•00 o.nd 7.00 o'clock
3/4• threod co.p
3/4' thre4d nipple
to surfoce For c\eo.n
out ond pressure bolonc:lng
Cend oF loterol on\y)
PRESSURE LATERAL CONSTRUCTION DETAIL
SCALE: 1 "=1'
Effluent Pumping System -2nd Compartment Drawdown
Effluent Pumping System for Cold Weather Applications (cw style)
Inspection Access
Riser ond Lid
Tank Adopter ---~
Slope Ground
Away from Riser
---PVC Splice Box with
Cord Grips
---Fiberglass Insulated Gosketed
Lid with Stainless Steel Bolls
1-bhi 11-61 t Discharge As sem bly
~ £ PVC Riser with Grommets
(bond to tonk adopter with
recommended odhesive) * Pea Grovel Backfill
Provide 1/4" Drain Hole
BIG R COMMERCIAL PARK immediately above check valve
H\./Y 6 , CR 221. AND CR 223 Provide 1-t/4" check valve OS
RIFLE, CO 81650 low os pos sible to prevent
SEPTIC T ANK DET AIL bo ckflow from 4" common
J ANU ARY 9 , 2009 pressure main
~ ~
Orenco Systems®
Incorporated
814 />JrrNAY AVENUE
SUTliERUN , OREGON
97479-9012
TELEPHONE:
(541) 459-4«9
FACSIMILE:
(54 l) 459 -2884
(cost or bolted) Effluent Discharge (2-1 /2'' Schd 40) below
frost line to 4" common pressure main
•----Tonk Adopter (cost or bolted)
Inlet Tee -----
..,,.
h~h level alarm set to tri gg er max .
6 above pump-on f loot level
pump -on/pump-off float differential set
to provide dose volume of 80 gallon s
tonk to hove minimum volume
of 2000 gallons
1HO 1111 I I Level Control
Float Assembly
T.M.H.Mil I I I Delete Check Valve
I, I , I . f I Vault Inlet Ports
• Flow Inducer (2)
'II " 1 Duplex OSI Effluent Pump
(Orenco PF200512)
! -==::....---= ~'I I Drain Port
I ~I f Filter Cartridge
Biotube® Pump Vault (Orenco PVU57-2419-L)
Potents I 4,439,323 & 5,492,635
Foreign Potents Pending
@ 1997, Orenco Systems, Inc. * Pea Gravel Backfill Recommended to Help Prevent Frost Heave EDW-TD-18
Rev . 1.0 (2/98)
AX100 Pod with Recirculation Tank Detail
Salo:N.T.S.~mrl
Screened-
Eflluent rrom
Septic Tonk
Recirculating Valve
Model MM4U
Recirculation Tonk
min. 3,000 gallon
one piece c:onc:rete
(Copeland Concrete)
Retum From Filter
level Control Float Assembly
Configure Floats to allow min.
500 gallon surge capacity
Duplex Orenc:o Effluent Pump
Model PF500512
Biolube Q!Pump Vault
Model PVU72-2419-L
BIG R COHHERCJAL PARK
H'JY 6, CR 221, AND CR223
RIFLE , ca 91650
AXIOO POD \JITH RECIRCIJLATION TANK DETAIL
JANUARY 9, 2009
~
Duplex Effluent Pumping System for Cold Weather Applications (cw style)
Inspection Access
Riser and Lid
Tonk Adopter ----
(cost or bolted)
Inlet Tee -----'
---PVC Splice Box with
Cord Grips
---Fiberglass Insulated Casketed
Lid with Stainless Steel Bolts
Orenco Systems®
lnex>rporated
814 /<JfrNAY AVENUE
SUTHERLIN, OREGON
97479-9012
1:-Att! !!:Ate Discharge Assembly
(Minimum 2")
BIG R COMME RCIAL PARK
H\o/Y 6, CR 221, AND CR 223
RIFLE, CO 8 1650 .
LIFT STATION DET AIL
JANUARY 9, 2009
-::-
h~h level alarm set to trigger mox.
6 above pump -on float level
pump-on/pump -off float different ial set
to provide dose volume of 200 ga llo ns
tonk to have minimum volum e
of 1250 gallons
~ t PVC Riser with Grommets
(bond to tank adopter with
recommended adhesive)
* Pea Grovel Backfill
Provide 1/ 4" Drain Hole
TEl.£PHONE:
(541) 459-4449
fACSIMIL£:
(541) 459-2884
Effluen t Discharge (2 ea. 2-1/2" Schd 40)
Below Frost Line
•---Tonk Adopter (cost or bolted)
1HS 1111 I I Level Control
Float Assembly
T.UW..11:11 I r Delete Check Valve
1111 I II I I Vault Inlet Ports
'> '> Flow Inducer (2)
.._ 'f 1 Duplex OSI Effluent Pump
(Orenco PF500512)
J r=r-c '-"I I Drain Port
'I-+-----Filter Cartridge
~----------------------~~----~~b-~~~~~re~~~-M1~0
Potents I 4,439,323 & 5,492,635
Foreign Patents Pending
@ 1997, Orenco Systems, Inc. * Peo Gravel Backfill Recommended to Help Prevent Frost Heave EDW-TD-18
Rev. 1.0 (2/98)
Pump Selection for a Pressurized System
Input Parameters
Orifice Size 1/4 Inches
Residual Head at Last Orifice 1.00 feet 100
Orifice Spacing 5.0 feet
Number of Laterals per Cell 5 I
PF5007 I
Lateral Length 64.0 feet
Lateral Line Size 2.00 Inches
1 ...........
"-.
90
Lateral Pipe Class/Schedule 40
Distributing Valve Model None I
"~
80
Manifold Length 36.0 feet
Manifold Une Size 2.00 Inches
Manifold Pipe Class/Schedule 40
Lift to Manifold 10.0 feet
Transport Length 300.0 feet j
I 70
Transport Line Size 2.50 inches -T ransport Pipe Class/Schedule 40 :c
Q
Discharge Assembly Size 2.00 Inches !:=.
1 PF5005
!'..... ~
60
Flow Meter None Inches "O m 'Add-on' FricUon Losses o.o feet :c
(,,)
-
I 50
Calculations E
IU
Minimum Flow Rate per Orifice 0.78 gpm c >-
Number of Orifices per Zone 65 Q
n;
Total Actual Flow Rate 50.6 gpm -
Number of Lines per Zone 5
{!.
I 40
% Flow Differential 1st and Last Orifice 2.1 % 30 I
Lift to Manifold 10.0 feet
Residua! Head at Last Orifice 1.00 feet
Head Loss in Lalerals 0.1 feet 20 t
Head Loss Through OistribuUng Valve o.o feet
Head Loss in Manifold 0.4 feet
Head Loss in Transport Pipe 5.2 feet
Head Loss Through Discharge 5.1 feet t 10
Head Loss Through Fla.v Meter 0.0 feet
'Add-on' Friction Losses o.o feet
Total Flow Rate 50.6 gpm 00 10
TOH 21.8 feet
BIG R COMMERCIAL PARK~ LOT 1
HWY 6 & CR221, RIFLE, CO
I I I
I Effluent Pumps r l PFSO Series
1/2hp to 3/4ho
.........
r--......
...........
:-...........
""' r-....
"~
~
t--... ............._ " --~ ~ ...............
-....... I'-. f\
........... ~ \
j ~ --· I ---
I ~ /
_, / "~
'
~ ... " .... 'J
-i_.....-v
~
__...
-
20 30 40 50 60 10
Net Discharge, gpm
-
I
v
\
r--.... ....
80
CB
Orenco Systems"
Incorporated
814AIRWAY AVENUE
SUTHERUN, OREGON
97479
Ttll.l FREE:
(Im) 348-!1143
T8.£PHONE:
(541l 459-i449
FACSIMllf:
(541)459-28114
www.orenco.com
1
.J
_,
APPENDIX A
son..s AND PERCOLATION REPORT
CRONK CONSTRUCTION INCORPORATED
CRONK
CONSTRUCTION
INCORPORATED
• 1129·24·Road
Grand Junction, CO 81505
970·245·0577, 970·257·7453 (fax)
Date:
Prepared by:
Client:
Property address:
Tax schedule No .:
Legal Descript.:
1.0 Soils Evaluation
son,s AND PERCOLATION REPORT
July 15, 2008
Thomas A. Cronk, P.E.
1129 -24-Road
Grand Junction, CO 81505
245-0577
Kent Cotten
KC Equipment
30585 Hwy92
Hotchkiss, CO 81419
970-250-3471
Big R Commercial Park, Hwy 6, CR 221, and CR 223 Rifle, CO 81650
The site consists of approximately 8 .93 acres of uncultivated native soil. Drainage is approximately 1 %
to the southwest. A percolation test/soils evaluation was conducted on the property of reference on
07 /14/08 by Tom A. Cronk, registered professional engineer (R.P .E.). The perc excavation trench
(excavation A) was located in the northeast comer of the property and approximately 35' south of the
north property line and 225' west of the northeast property pin. Additional perc holes were located 35'
east of the trench (excavation B) and 15' west (excavation C).
Aperc excavation trench (excavation A) was extended to a depth of 120" below ground surface (BGS).
There was no evidence of ground water or high seasonal water table in the open excavation to a depth of
12011 BGS . The soils evaluation indicates three distinct soil horizons underlie the site. A lithological
description follows :
depth (in .)
0° -811
8° -9611
96" -12011
description
1-1/2" pitrun manfill
sandy clay/clayey sand, tan; hard; friable
clayey sand, tan
Page A-1 of A-2
,J
Pere holes were constructed in excavation A at the surface and at depths of approximately 38 in . and 70
in. Additional perc holes were constructed in excavation B at a depth of 42 in. and in excavation C at a
depth of 43 in. The holes appeared to be well saturated at the time of the test. Results of the percolation
test arc shown in Table 1.
TABLE 1
Percolation Test Results
Bist R Commercial Parle
Depth Time on 07/15/08 Ii.ms Pere
Drop Rate
13 :16 13:36 13 :56 14:16 min/in
<Al0"-8" 4.S625 5.125 5.5625 5.875 6011.3125 46
(A)38" ·48" 3.625 4.125 4.625 S.125 6011.50 40
(A) 70" -76" 3.375 3.75 4.125 4.375 60/1.0 60
<Bl42" -52" 4.0 4.5625 4.875 5.25 60/1.25 48
(C)43" -SO" 3.875 4.8125 5.5 6.125 60/2.25 27
2.0 Limitations
This document is representative of the site conditions disclosed at the specific time of the site
investigation . Site conditions are subject to change from external events both manmade (irrigation or
water feature construction) and naturally occurring (flooding or excessive precipitation). Cronk
Construction Incorporated is not responsible and accepts no liability for any future variation in site
conditions.
Cronk Construction Incorporated represents this report has been prepared within the limits prescribed by
the owner and in accordance with the current accepted practice of the civil engineering profession in the
area. No warranty or representation either expressed or implied is included or intended in this report or
in any of our contracts. /J V
SEAL =%-; n-w.Y ~
Thomas A. Cronk, P.E.
Date
Page A-2 of A-2
J
APPENDIXB
SYSTEM OWNER'S DISCLOSURE
J
·! . 4 .... ..
"
• . . 4' • :~. • .... . .. . . . . .
·,.:~·~-.. flt._ Ow.ner' s Discl(>.til\lc,~
.. -• .4 • ---~ ..... :::·~ .. • -· • • • • •
' ' -' . . ~ . .
Disclosure.of Requirements for AdvanTex$ Trea~~nt Systems
-.
lrqtr.uctions to the prospective AdvanTex Treatment System Owner: Please review thrt following
Di~closurefor review and signatures. The purp9se of this Disclosure is to ens"re you are awar.e
th~ AdvanTex Treatment System requires proper installation and maintenance for the zystem to
·f!perpte properly. This require~ installation and maintenance by trained personnel, and maintaining
a qec/!cated telepho,ne line to the system, as described herein. With your approval, please sen(J a
copj of the signed Disclosure to the Orenco Dealer. If no Dealer, send directly to Orenco, Attn:
SystetM Engineering, 814 Airway Avenue, OR 97479.
Ilw~, as prowectivc owners of an Orenco Systems~, Inc. commercial AdvanTex Treatment Sy~
un:der~d tMt I/we are purchaSing an ons.ite wastewater treatment system ~t us~s advanced ~water
ti'~aime~t "technologies. The Installer of this system must be trained, and the instal1f;ltion overse~n/by Oie11cto
or fiµ Orenco Authorized Dealer. I/we agree to have the.sys.tem installed by a tr~~~cl ~Q.d sw),q,tjt1~··
lij~t~Uer~ ·
This advanced wastewater tr~atment system may have been permitted l\Ilder fc;c;ler~ sblte, or local
r~gui~tions that require the system owner to obtain a Service Contract for ongoing ope.ration and
nllPri~~ce (O&M) from a professional provid~r. I/we understand that Orenco, as the tnan\tfhC.Pll'er,
i'eqUires. ongoing O&M by a trained and authorized AdvanTex Treatment Systems Service Provide.r ~ -~ · . . _ ·
cob(lj.tion of warranty. Ilwe agree to provide op~ration and mainten~nce by a. trainP4 a.nd-.~~t)g~4.···· · · --
Semce-'Provider. · . .. . . .
.. .....
This ~van~ wastewater treatment system also includes. an Orenco telemetrY control pan~l.-~ ~9~~ _: · . ·. -
pro.vi~g alarm notification to the Service Provider, the telemetry control panel allows re.mo~ ~·~~·*e .·· · · · ...
p~cl by 'Orenco, or Orenco' s Authorized Dealer, to assist the Service Provider in mei.n~g .tli.e' 'Y~ . , · ·. : .·:
1[W¢'8Iso ~gr~e to p'1t'chase and maintain ~ de4icated t~lephone servic.e to the :PBD{I ~ l9P.1'-~;t~o-·: · .... ' ·,
sy.st~m]s '11 ~peration. ..· ..
I/we~so agree t9 provide a copy of this System Owner• s Disclosure to any sub.seq~ent b:UY.Cr of tWs
Sy$tem.
-'
SiteAddress: _-------------------------~--· . . Street/PO Box .-.•
City State/Province Zip Code/Postill Code COU,Jir.ey
Printed N~e: __________ _ Printed Name: __________ ..,....._
·Si~~~:-------------Signature : ____________ _
Date:_.... ____________ _ D~te: --------.,...--...---....... ----
..
-·
..
u • '.