Loading...
HomeMy WebLinkAboutApplication - PermitGarfield County Building & Planning Departm ent 108 Bth Street Suite 401 Glenwood Springs, CO 81601 · Phone: (970)945,8212 Fax: (970>384·3470 Project Address Parcel No. Subdivision 24 CR 138 212335200186 NEW CASTLE, CO Owner lnfonnatlon Address Conrad Wagner 0024 CR 138 Glenwood Springs CO 81601 Permit NO. Bl:..RE-9-j 0-17 42 Permit Type: ~esidentijl Building Wqtk Clas~cation: New Permit Status: Active Issue Date: 1 0/4/201 0 Expires: 04/02/2011 Section Township Range Phone Cell 970·947 ·0020 Contractor(s) Phone Primary Contractor Required Inspections: Proposed Construction I Details Steel building for garage. FEES DUE Fee Plan Check Fee Residential Building Fee Total: Amount 5518 54 5797.75 $1,316.29 Valuation: Total Sq Feet: FEES PAID $ 71,976.00 2400 lnv Total Paytype Amt Paid Amt Due lnv # BLRE-9-10-20505 S 1 ,316.29 Check # 7173 Check# 7198 S379.05 5937.24 $0.00 Forln•pecthm• call: 1 (888}868-5306 Inspection IVR See Permit Record Building Department Copy I Monday, October 4, 201 D 2 2 3 4 6 7 8 9 10 11 12 Driveway Permit: GARFIELD COUNTY BUILDING PERMIT APPUCA TION 108 8"' Street, Suite 401, Glenwood Springs, Co 81601 Phone: 970-945·8212/ Fax: 970-384·3470 I Inspection Line: 888·868·5306 www.garfield ·countv.com Ph: Height: J &. , O 1 ~ Septic: ~{h o lSDS Owners valuation of Work: NOTICE ~-z. No . of Floors: oCommuni ~· This application for a Building Permit must be signod by the Owner of the property, described abo•e, or 1t1 authonzed lj!ent If the signa~ below is not thai of the Owner, a separ.ue !coer of authority, signed by the Owner, must be pro•idcd with thU Application. Lrt•l Arrps. A Building Permit cannot be issued without proof oflegal and adequate accm to the property for purposes of mspeetiOliS by the Building Ocpanment. Other Pcrmig. Multiple scpara~ permits may be requirod. (I) Stlte Electrical Permit, (2) County ISDS Permit. (3) another pcnrut required for usc on the property identified Gbovc, e.g. Swe or County Highway/ Road Access or a State Wasttwater Discharge Permit Vgld Permit. A Buildins Permit becomes null and void if the wort< authorized is not commenced withio 180 days of the date ofissuance and if wort< is suspended or abandoned for a period ofl80 days after commencement. ' CERTIFICA T!OS 1 hereby ccnlfY that llum: lUll this Applict~ti4n and that the information contained abo\"t: is true and corteet I understand that the Building Dcpan:ment accepts the Application. alo ng with the plans and spec ifications and other dati submitted by me or on my bcbalf(submtttals), based upon my c:eni6cation as to a=ney. Aswminl! campletcncu of the submiaals and appro \'tl of this Applation. a Building Penni! will be issued l!fltlling pcmussion to me, as OwDCt, to construct the ~s) and facilities detailed on the subminals re•icwcd by the Bwlding Ocplll1ment. ' lo consideration of the inuan~e of the Bwlding Permit. I ag~tt th.1! 1 and my ogcnts will comply with pro•istons of any federal, state or local law regulating the work and the Gatiield County Building Code, IS OS regulations and appl icable land use regulations (County Rcgulation(s)). I acknowledge that the Buildin g Pcnnit IMY be suspcuded or n:•"Okcd. upon notice from the County, iftbe location, construcrion or usc of the structure(&) and flcility(ies), descn'bed above, 111: not in ~ompliancc with County Regulauon(s) or ~ny otbcr applicable law 1 hereby grant pc:nniuion to the Bwlding Dcpan:mem to enter the property. dcsmbed above, to tnspcct the wort< I further acknowledge thai the inuance of the Building Pc:nnit does not ptc\'ent the Building Official from ; (I) requinllg the correction of errors 111 the submiruds,tfany, disco• wed after ISSU&JJCe, or (2) stopping constniCtion or usc of the sll'UCt\lre(s) or facil ity(ics) if such is in •iolation of Coun ty Regulation(s) or any other appl icable law. Rc\iew of this Application. including subnuttals, and inspections of the wort< by the Bui ldmg Dcpamnem do not coostttute 1t1 acceptance of responsibility or liab ility by the County of crron, omissions or discrepancies . As the Owner, 1 acknowledge that responsib ility for compliance with fcden~l, state and local laws and County Re!llllati ons rest ,.;th me and my authorized agents, includJng without limi11tion my ~~ehiteet dcslgncr, engineer and/ or builder. 1 ACK."iOWLEDGE THAT I HAVE READ Ml> UNDERSTAND mE NOTICE &; CER.TIFlCA TIO~ ABOVE. .:2o J D DATE STAFF USE ONLY Special Conditions: Adjusted Valuation: Plan Ch«:k Fee: Permit Fee: Manu home Fee: Mise Fees: 7/, q7b.OO S/8. 5Y 797.7.5 --... ! ISDS Fee: ' Total Fees: Fees Paid: 'D~ Balance Due: ~ & Issue Dale: JSDS i'\o & Issued Date: I 13Jb.t.1 3lq , CJ37.'Z.lf -1142.. Setbacks: OCCGroup: I, Const Type: 1[. 6 .::S:./< C Zoning: R FZS .. _gz5 ~ ; 12-3 I/<.C SIO BLDG£: Lf. ~ .... ~f/1. .. ~ 7 9;/~t:J ;~: ;~~ 7)~~1"" ~1"1 ROYAL DATE ' APPROVAL .... DATE , The following items are required by Garfield County for a final Inspection: 1) A final Electrical Inspection from the Colorado State Electrical Inspector. 2) Permanent address assigned by Garfield County Building Department and posted at the structure and where readily visible from access road. 3) A finished roof; a lockable building; completed exterior siding; exterior doors and windows installed; a complete kitchen with cabinets, sink with hot & cold running water, non-absorbent kitchen floor covering, counter tops and finished walls, ready for stove and refrigerator; all necessary plumbing. 4) All bathrooms must be complete, with washbowl, tub or shower, toilet, hot and cold running water, non-absorbent floors, walls finished, and privacy door. 5) Steps over three (3) risers, outside or inside must be must have handrails. Balconies and decks over 30" high must be constructed to all IBC and IRC requirements including guardrails. 6) Outside grading completed so that water slopes away from the building; 7) Exceptions to the outside steps, decks, grading may be made upon the demonstration of extenuating circumstances., i.e. weather. Under such circumstances A Certificate of Occupancy may be issued conditionally. 8) A final inspection sign off by the Garfield County Road & Bridge Department for driveway installation, where applicable; as well as any final sign off by the Fire District, and/or State Agencies where applicable. A CERTIFICATE OF OCCUPANCY (C.O.) WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. A C.O. MAY TAKE UP TO 5 BUSINESS DAYS TO BE PROCESSED AND ISSUED. OWNER CANNOT OCCUPY OR USE DWELLING UNTIL A C.O. IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. I understand and agree to abide by the above conditions for occupancy, use and the issuance of a C.O. for the building identified in the Building Permit. Bapplicationdecember2007 Building Plan Review Description of Work: Steel building for garage. Bin#: Location Address: 24 138COUNTY RD NEW CASTLE, CO Case Manager: David Bartholomew Plan Case Number: BLDG-9-1().6584 Parcel: 212335200186 Application Date: 09/0&12010 Building __ / ___ ,Engineered Foundation __ IV.,.~.r_14 __ Driveway Permit ___ / __ Surveyed Site Plan _...;.tJ.......,/_A_-:SeptJc Permit and Setbacks ___ / __ Grade/Topography 30% / ---~-Attach Residential Plan Review List / _____ Minimum Application Questionnare ,...; {_,4 Subdivision Plat Notes I I'lL A Fire Department Review _ ___;/ ___ Valuation Detennination/Fees / ------Red Line Plans/Stamps/Sticker ___ /____,.~.Attach Conditions l c ___ 7 __,._,...A ppllcation Signed --7~::o--..JP ian Reviewer To Sign Application ____ _.ParceUSchedule No. __ tJ...;.'(._'A~_-40# Snowload Letter-Manu. Homes / ____ _..Soils Report Cont01 c ts Owner: Conrad Wagner Applicant: Conrad Wagner Applicant Phone: 97~947-0020 Em a it Planning/Zoning / Property Line Setbacks / 30ft Stream Setbacks / Flood Plain I Building height 7 Zoning Sign-off tU/4 Road Impact Fees ;tf.A HOAIDRC Approval / Grade/Topography 40% / Planning Issues 7 Subdivision Plat General Comments: 51-eel r~e fe~tdeJrt tu I ~hYhfej~p 29. qq I Z'loo fJ-x 29 .99 :: 71, 976 v ,1/u.A-nb'J/1 1J 7JI CJ7b, (!!L ~YW11 t {:fe_ 797.75 [2tvJ-ew .Pee 51 B .5'1 TO TAt.. I 3/{:,.z_q ~+.Pd 379. ~5 Pae :' ~ 37.24 FEE ESTIMATE FOR S/F STICK BUILT HOMES (ALL FEES ARE ESTIMATES UNTIL FINAL PLANS ARE REVIEWED) Applicant: Job Address: Subd-Lot/block: FINISHED LIVING SPACE: sf X 74.68= ------------------------- UNFINISHED BASEMENT: sf X 41.00= ------------------------- CRAWL SPACE: sf X 9.00= ------------------- UNCOVERED PATIO/DECK: sf X 12.00= ------------------------- COVERED PATIO/DECK: sf X 24.00= MISC: --------------------------- MISC: TOTALVALUATION: Y 3 p \)Q THIS SECTION WILL BE DETERMEND BY GARFIELD COUNTY BUILDING & PLANNING PLAN REVIEW FEE: PERMIT FEE: TOTAL: PERMIT: SEPTIC= PERC: GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS For SINGLE FAMILY DWELLING CONSTRUCTION Including NEW CONSTRUCTION ADDITIONS ALTERATIONS And MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. When reviewing a plan and it's discovered that required information has not been provided by the applicant, this will result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor shall be required to provide this information before the plan review can proceed. Other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. TWO (2) SETS OF CONSTRUCTION DRAWINGS & TWO (2) SITE PLANS MUST BE SUBMITTEDFOR ALL APPLICATIONS. Please review t~is document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. Any project with more than ten (10) occupants requires the plans to be sealed by a Colorado Registered Design Professional. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechan ical codes, applicants are requested to review the following checklist prior to and during design . Applicants are required to indicate appropriately and to submit the completed checklist at time of application for a permit. Plans to be included for a Building Permit, must be on drafting paper at least 18"x24" and drawn to scale. Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks, balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line and original grade. A section showing in detail, from the bottom of the footing to the top of the roof, including re-bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house-rap, (which is required), siding or any approved building material. Engineered foundations may be required. A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. wind speed, wind exposure B or C, and a 36 inch frost depth. All sheets to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be in compliance with the 2009 IRC, and 2009 IECC. 1. Is a site plan included that identifies the location of the proposed structure or addition and distances to the property lines from each corner of the proposed structure(s) prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Properties with slopes of 30% or greater must be shown on the site plan. (NOTE Section; 106.2) Any site plan for the placement of any portion of a structure within 50 ft. of a property line and not within a previously surveyed building envelope on a subdivision final plat shall be prepared by a licensed surveyor and have the surveyor's signature and professional stamp on the drawing. Any structure to be built within a building envelope of a lot shown on a recorded subdivision plat shall include a copy of the building envelope as it is shown on the final plat with the proposed structure located within the ~e. Yes ---=:V;....___ • 2. Does the site plan also include any other buildings on the property, setback easements and utility easements? Please refer to Section 3-301 in the Garfield County Zoning Resolution if the property you are applying for a building permit on is located on a corner lot. Special setbacks do apply. /"' Yes V ----- 3. Does the site plan include when applicable the location of the I.S.D.S. (Individual Sewage Disposal System) and the distances to the property lines, wells (on subject property and adjacent properties), streams or water courses? Yes.J~ {k 4. Does the site plan indicate the location and direction of the County or private road accessing the property?. _/ Yes ~ _......:;;; __ _ 5. Have you provided any RESOLUTIONS and/ or LAND USE PERMIT(S) associated with this property? , __,- Yes if Yes please provide a COPY. No_-=~---- 2 6 . Are you aware that prior to submittal of a building permit application you are required to show proof of a legal and adequate access to the site? This may include (but is not limited to) proof of your right to use a private easement/right of way; A County Road and Bridge penn it; a Colorado Dept. of Highway Permit, including a Notice to Proceed; a permit from the federal government or any combination. You can contact the Road & Bridge Department at 625-8601. See phone book for otheragen~ Yes v ----- 7 . Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the IRC or per stamped engineered design? Yes v-::' 8. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and earth? Yes No N Jl\ 9 . Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces and soffits? Yes No }.(A 10 . Do the plans include design loads as required by Garfield County for roof snow loads, (a minimum of 40 pounds per square foot up to & including 7,000 feet above sea level), floor loads and wind loads? / Yes V ------ 11 . Does the plan include a building section drawing indicating foundation, wall, floor, and roof constructi_on~ Yes V __ .:._ ___ _ 12 . Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters o_!)oists or trusses? Yes V __ ..::...... ___ _ 13. Does the building section drawing or other detail include the method of positive connection of all columns and beams? Yes V 14. Does the elevation plan indicate the height of the building or proposed addition from the undisturbed grade to the midpoint between the ridge and eave of a gable or shed roof or the top of a flat r~or?fluilding height measurement usually not to exceed 25 feet) Yes. __ ..z:~--- 15 . Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase II certifications or phase II EPA certification? Yes No N b ~ 3 16. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the IRC? Yes _____ No_ ..... N+-+.~-\-· __ _ 17. Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements comply with the requirements of the IRC? Yes f::i .t\ 18. Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable rooms? Yes ('If! 19. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety glazing for these areas? Yes /'1 (< No ____ _ 20. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? Yes N es 21. Do you understand that if you are building on a parcel of land created by the exemption process or the subdivision rocess, are building plans in compliance with all plat notes and/or covenants? Yes _.......,.__.....;:..__ 22. Do you understand that if you belong to a Homeowners Association (HOA), it is your responsibility to obtain written permission from the association, if required by that association, prior to submitting an application for a building permit? The building permit application will be accepted without it, but you run the risk of the HOA bringing action to enforce the covenants, which can result in revocation of permit issued. Additionally, your Plan Review fee is not refundable if the plans have been reviewed by the Building Department prior to any action by the HOA that requires either revocation or substantial modification of the plans. Yes N h 23. Will this be the only residential structure on the parcel? Yes .f¥. ~ No lfno-Explain: ______ _ 24. Have two (2 ~co plete sets of construction drawings been submitted with the application? Yes 1 25. Do you unders~d that the minimum dimension a home can be on a lot is 20ft. wide and 20ft. long? Yes v · _ __:;. __ _ 4 26. Have you designed or had this plan designed while considering building and other construction code requiremen ~ Yes ............ ·----- 27. Do your plans comply with all zoning rules and regulations in the County related to your properties zone districV" Yes. _______ _ 28. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by the Ga~County Building Department? Yes ____ _ 29. Do you understand that approval for design and/or construction changes are required prior to the application ~ese changes? Yes ----- 30. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application submittal and that you will be required to pay the "Permit Fee" as well as any "Road Impact" or "Septic System" fees required, at the time you pick up your building permit? Yes V 31. Are you aware that you must call in for an inspection by 3:30 the business day before the requested inspection in order to receive it the following business day? Inspections will be made from 7:30a.m. to 3 :30p.m. Monday through Friday. Inspections are to be called in to 888-868;.S-306. Yes ~ No _______ __ 32. Are you aware that requesting inspections on work that is not ready or not accessible will result in a $50.00 re-insg.cx:tion fee? Yes V __ :...__ ____ __ 33. Are you aware that you are required to call for all inspections required under the IRC including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of the building? V Yes ---------- 34. Are you aware that the Permit Application must be signed by the Owner or a written authority being given for an ~ent and that the party responsible for the project must comply with the IRC? Yes V ---------- 5 35. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups, unless you as the homeowner are performing the work? The license number of the person performing the work will be required at time of applicable i ~. Yes ________________ __ 36. Are you aware, that on the front of the Building Permit Application you will need to fill in the Parcel/Schedule Number for the lot you are applying for this permit on prior to submittal of a building permit application? Your attention in this is appreciated. Yes £/ 37. Do you know that the local fire district may require you to submit plans for their review of fire safety issues? / Yes (please check with the building department about this requirement) 38. Do you understand that if you are planning on doing any excavating or grading to the property prior to issuance..Pf a building permit that you will be required to obtain a grading permit? Yes __.V:;...._ __ 39. Are you aware that if you will be connecting to a public water and/or sewer system, that the tap fees have to be paid and the connections inspected by the service provider prior to the issuance of a Certificat~ccupancy? Yes _____ _ 40. If you anticipate obtaining a water tap from the City of Rifle, please provide a letter indicating that the City will provide water service. No building permit application will be accepted without such a letter. Yes N k: I hereby acknowledge that I have read, understand and answered these questions to the best of my ability. ~f.w~ -2.DJ b Date 'MD '1'·0 Phone:.,9.,Y:J • D 0 Q.o (days); _.a..{">o~:.o~}~g~ ....... .3_. _,.'f'-'0:;.13 ..... '--( evenings) b I 8' -LJ. to i .2 Project Name: \..!d~tJ...)!\ Cl" G a.. r Q,~ e. Project Address: 0-?, ff: Cs2 f)-;J.y B o 94. 6 13 ss G ~ eqf.d6Y>c\ S t.,_\ ns ~ ce> ~Jbol Notes: If any required information is missing delays in issuing the permit are to be expected. Work may not proceed without the issuance of a permit. If it is determined by the Building Official that additional information is necessary to review the application and plans to determine minimum compliance with the adopted codes, the application may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review, delay in issuance of the permit or delay in proceeding with construction. bpminreqsfJun201 0 7 GARFIELD COUNTY BUILDING REQUIREMENTS Codes: 2009 IRC, me, IFGC, IMC, IPC, 2009 IECC. Setbacks: Check subdivisions and zone district for setback requirements. Snow load (measured at the roof! Not ground): 40PSF up to 7000ft. elevation. Seismic design category: B SOP SF 7001 ft to 8000ft. 75PSF 8001 ft to 9000ft. I OOPSF 900 I to I OOOOft. Weathering probability for concrete: Severe. Termite infestation probability: None to slight. Wind speed: 90mph. Decay probability: None Wind Exposure: B or C (see section R301.2.1.4) Frost Depth: 36in. to 8000ft. elevation. 42in. 8001 and above. Winter Design Temperature: Minus 2 to 7000ft.; minus 16over 7000ft. elevation. Air Freezing Index: 2500deg F-days to 7000ft.; over 7000ft. to be determined by Building official Ice shield under-layment required. Mean Annual temp: Variable Insulation: Windows/doors U=.35, Skylights U=.6, TBL 402.1.1, 2009 IECC. Minimum R-Values: • Ceilings/roofs R values are R-38 stick built structures. R38 log construction and steel rafter construction. • Walls R values are R-20 wood frame. See Table 402.2.5 2009 IECC for steel framing • Floors R-values are R-30 or enough to fill cavity. • Basement wall R-values are R-1 0 /13. • Slab perimeter R-values and depth is R-10/24in. • Crawl space wall R-value are Rl 0/13. If floors over crawl space are not insulated, the crawl space walls must be insulated. Basement wall must be insulated to frost depth. Common walls garage to house must have R-20 insulation. Common ceiling/floor garage to house must have R-20. Take precautions to protect plumbing in these areas. 8 KURTZ & ASSOCIATES, IN CORPORA TED Structural Consultants 5012 County Road 154 Glenwood Springs, CO 81601 Phone (970) 945-6305 Fax (970) 945-1093 FIELD OBSERVATION REPORT TO: ATTN: Precision Cut and Design Conrad Wagner 024 Cty Rd 138 New Castle, Co. THE FOLLOWING WAS OBSERVED: DATE: September 20, 2011 PROJECT: Steel Building @ 024 Cty Road 138, Lot No.2 Garfield County, CO . PRESENT AT SITE: 1. Brian Kurtz 2. Conrad Wagner, Precision Cut & Design Brian Kurtz, P. E. of Kurtz & Associates, Inc. perfonned a structural inspection ofthe noted building . At the time of the inspection the foundation and concrete floor slab-on-grade were in place . At that time the steel structure, the roof and wall framing, and the steel roofing and siding were substantially erected and in place. Mr. Kurtz also reviewed the construction documents from the building supplier (Chief Buildings, dated 03/30/2007). The building measures, in plan, approximately 60-0" east-to-west by 40' -0" north-to-south. The primary framing system consists of structural steel frames spaced at 20'-0" on center. The two (2) interior frames clear span 40'-0", and the east and west •end watr frames include an intennediate support column. the building height at the eave lines is approximately 17' -0". The primary structural steel frames were erected and fully bolted. Roof framing was complete. The 8" deep steel roof purlins were erected and bolted in accordance with the construction documents, and the roof sheathing was installed and screwed to the purlins in accordance with the construction documents. The exterior wall framing (8" steel girts) and steel siding was also fully erected, bolted and screwed. The layout of the exterior doors, as erected, varied from the construction documents. The wall construction has been erected in a structurally acceptable manner. This is true in all bays, including the bays where the exterior doors have been relocated relative to the construction documents. The wind load resisting system for the buildings consists of the four (4) rigid frames to resist north-to- south lateral loads and one set of X-braces in the both the north and south walls to resist east-to-west lateral loads. The X-braces consist ofS/16" diameter seven wire steel cables in the middle, 20'-0" wide bay of both the north and south walls. The X-braces are manufactured to bolt to the top and bottom of the rigid frames. The X-braces, therefore, measure approximately 17' -0" high by 20' -0" wide. The X-braces, as shown on the construction documents were shown in the center bay of three (3)-20'-0" wide bays. The construction documents from ChiefBuildings show two (2)-14'-0" x 14'-0" overhead garage doors on each end of the building (on the east and west ends), and two (2)-3 '-4" x 7' -2" man doors on the north and south sides. Mr. Wagner elected to erect the building with a different door arrangement. The 2 east and south walls have been erected with the door openings as shown on the construction documents. On the west wall one garage door has been installed in accordance with the construction documents, but the north half of that wall has been framed as a solid wall. The north wall has been framed with a garage door in the west bay, and a man door in both the east bay and the center bay. The man door in the center bay creates a physical conflict between the door and one leg of the intended X-brace. Consequently, one leg of this X-brace had not been fully installed. I recommended that this leg be relocated to the east bay of the north wall so that rather than an X-brace, the wall would contain a V-brace. From a load resisting perspective, the V-brace is equally effective as the intended X-brace, and is structurally acceptable. Note that the X-brace cables are manufactured with attached eyebols to bolt to the primary steel frames, and all of the frame columns are pre-drilled to accept the eyebolts, so that relocating one leg of the brace is a straightforward process that does not require any modification ofthe existing structural members. West Slope Testing & Inspection LLC 3177 Glendam Dr. Grand Junction, CO 81504 Phone:970-434-6988 Cell: 970-260-2844 Date: 9-28-11 Inspection Report Project: Metal Shop Building Address: 24 CR 138 Glenwood Springs, CO Building Permit No.: BLRE-9-10-1742 General Contractor: Conrad Wagner Inspection of shop fabrication or field work at job site: Field Report#! Page 1 of 1 Report: Visually inspected the high strength bolting at the main frame column & rafter connections. Also randomly tested a minimum of two bolts per connection at the main frame column & rafter connections for "snug tightness" as allowed per the building manufactures plans. The high strength bolting inspected as outlined above appeared to be in conformance with the plans for bolt size & grade, and the A325 high strength bolts appeared to be tightened to a minimum of"snug tight" as per the building manufactures plans. To the best of my knowledge this completes the special inspection of the high strength bolting as outlined above. Inspectortrechnician: Douglas E Young P~L.J4.:( CWI ~e(,~1~g QC1 EXP. 7/112014 Permlf Card Garfie:d County fouilding a11d Planning De lartmen! 108 ath Stre2t, Scite 401 Glenwood Spnngs, CO e 601 Phone. (970)945-82 ·2 Fax : (970)3E4-3470 POST ON SITE Permit NO. BLRE-9-1 0-17 42 Issue Date: 10/4/2010 -------· AGREEMENT r Permit Type: ReSidential Building Work Classificelicm: New. Expires : 04/02/20•11 In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structured for which this pem1it is gnmted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction cf the above described structure, the permit may then be revoked by notice from the County Building department and IMMEDIATELY B~;COME NULL AND VOID. Residential Building Parcel #:2123352001 86 ------------·------------------------------------------------------------ ]owner's Name: _C_o_n _ra_d_W_a~g_ne_r _____ ~~----------Owner's Phone: 970 ~947 ~00~_0 __ ~ j Joh Adores:;: 24_ C~ 138 ~ l NE.~W CASTLE , C•::) Totc.15G•Jare Feet: . 2400 ___ ~ a:z::.·mt ... ~m~~~rm~=l:l'ro:::l"""'"~*'""•"""""III<ZlO==m•cl:2•:u:::::c=""'""=··~-~c=:utK~~....,.. ... :::x ~ r COJlt;i~t9i(S_) _____ -_--·---P_h_on_e ____ ~'!.~·~··aclo• I L __________ _ ~ -. ----· I Work Descnptoon: Sleet bu ilding fo · garag•. l L_ rfny :~~~~ Fo~t.ers Fcundauon W alls r-L:_rc.ml ng lnspedion Scheduling Code iorywail ------------------------~~~----------------Final 135 160 175 +---------- ~05 ADDITIONAL INSPECTIONS MAY BE REQLIIR E:.D POST THIS IN CONSPICUOUS PLACE WHEN CO I·JSrRuCTION IS STARTED For l n spe ctton s Call· 1-888 -868-53fl:, · Account Account: R040429 Location Parcel Number 2123-352-00-186 Situs Address 24 138 COUNTY RD City New Castle ZlpCode 81647 Tax Area 004-1G-F-004 Legal Summary Section: 35 Township: 5 Range: 90 A TR IN THE NW4 CONT 34.685 AC AKA LOT 2 GABOSSI SUBDIVISION EXEMPTION. Transfers Sale Price $226,900 $700.000 Tax History Tax Year Taxes *2010 $2,433.80 2009 $2,433.80 *Estimated Owner Information Owner Name WAGNER, CONRAD L & MARSHA L Owner Address 0024 COUNTY ROAD 138 GLENWOOD SPRINGS, CO 81601 Assessment History Actual (2010) Primary Taxable Page 1 of 1 $528,820 $42,090 Tax Area: 004 Mill Levy : 57.8240 Type Actual Assessed Acres Units Improvement $308,820 $24,580 1.000 Land $220,000 $17,510 34.685 Sale Date Doc Type Book Page 03/03/2003 WD 8 : 144~ P: 667 04/1812001 QCD 8 : 1246 P: 776 04/1812001 PRO 8 : 1246 P: 773 04/1812001 LTR B: 1246 P : 772 Images • Photo • Sketch • GIS https://act.garfield-county.com/assessor/taxweb/account.jsp?accountNum=R040429 9/8/2010 .S.ENERAL. STI'WC:.l\JRAL. NOTES !SoENEAAL REGUIREMENTS 1. Doatsn I& b<:l&od on tho :2005 odl"on oP tho lnt.rnatlonal 6ulldlns C:.odo (lee.). 2.Doetsn Llvo Load&• a. RooP (5no>'~) .......... 40PSF b. Y'llnd .......................... '10 MPH Saelc. Y'l!nd Spoed, S &ec.ond gvst c.. omc.o Floor ......... SOPSF S.AII d lm o n&lon&, olovatlons and dotall& on strvc.tvral doc.vmonte ehall bo voriPiod agalnet the arc.hlt.oc.tvral doc.umont& prior to c.onetrvc.tlon or Pabrlc.atlon. 4.n,o c.ontrac.t atruc.tura l doc.umont& and epoc.IPic.atlone roproeo!lnt tho c.omplotod &truc.tvre . n,o c.ontrac.tor ehall provldo all mea&urea noc.o&&ary to protoc.t tho &truc.turo and oxh•tlns adJac.ont otruc.tvre& and vtllltlee. 5.C:.oordlnato all oponlnge through Floor&, >'lOll& and rooF& >'lith Moc.han lc:al and Eloc:trlc:al C:.Ontrac.tore. NotiPy engtnoer oF any opening& to bo c:ut In etrvc:tural ayatom&. FOUNDATIONS !.Foundation Do&lgn ·111 ba&od on Sail& Report ll 101-154 b4 Hep>'~orth-Pa>'llal< e.eot.c:hnlc.al, Inc.., dated Fobrvary 1, ::fool. Maximum doalsn eoll boarlns c:apac.lty• 1500 PSF. n,o C:.ontrac.tor eholl revlol'l tho Salle Report ond Polloi'! all all roc:ommondat lone thoroln, lnc.ludlng , but not llmlt.d to oxc:avatlon, &Ito c:ondltlone, dralnago, b<:lc.kllll anil c.ompa.otlon, &lab-on-grade c:on&truc:tlon, dralnogo ay&tome, and &lt. ln&poc.tlon roqulrome~te . 2 .AII Pootlnge are to boor on undleturbod natural belc:"lng materia l& or c.ompac.t.d etruc.tural Pill. C:.Ompac:tlvo eFFort For &trvc.tural Pil l &hall bo In ac.c.ordanc.o >'lith the Sail& Engln .. or'& roc.omm .. ndotlon&. B<oartns eoll& (natural and c:ompac.ted) eholl b" lnepec:ted and approvod by the Sallo !:nglnoor prior Footing p la.ooment. S.Avold e><.ooulvo "'"ttlng or drying oF the """ovation, ke"plng the e><.oovatlon reaaonob ly rree oF >'later during plac:em,.nt oP • c:onc.rete For Pootlng&. 4.e. .. noral Rea,ul romont&• a . Foundation >'~o ll e With b<:lc.kPIII on only one >'lOll Fac:e &ha ll hav" all &upportlng Pramlng &y&tem& or temporary brac.lng In ploc." prior to p lac.lng b<:lc.kllll (unleee noted other>'~l&o on plan). 1 b. eac.kllll on >'loll& l'llth Pill on both elde& to bo c.ompac:ted In equal liFt& eoc:h eldo oP wall . C:.ONC:.RETE AND REINFORC.IN.S. STEEL I.AII c.onc.rete ehall attain epoo PSI c:ompreeelve strensth l'!lthln :2e day. e><c.ept ae Polio>'~&• C:.onc:ret" For oxterlor Plato-tori< and garage rloore &hall attain 5,!500 PSI c:ompreeelve etrensth wlthTn :lei day&. I :2.Uee Type 1-11 Portlc:>nd C:.emont (ASTM C:.l50) with 4-b~ air <>~tralnment. C:.onc.rete asgregate to bo normal "'"'Sht (&ton<?). 6.Pertorm all c.<>o:-ln-ploc.e conuete >'lork In ac.c.ordanc.e >'lith I "S!:>ec.IPic.atlon& For l'>truc.turol C:.onc:rete Por 6ulldlngo,' AC:.I SO I··e4, unlee& noted otherwl&e . Provide hot or c.old l'teot'hor protec:tlon1 ..,e,. ACI 305 or 90b. · 4.'RelnPorc.lng &teel &hall c.onForm to ASTM A615 · 114 and &mallor ..... .S.rade 401 415 and larg·•r ..... c!orade t>O 5.Horlzr.>ntol r "lnPorc.lng &t.el ehall bo maao c.ontlnuoue by lap,,.ng • bore a minimum oF 62 b<:lr diameter& at all apllc:e& and providin g c;o,·ner baro. Fabrlc:atlon and lnotallatlon oP ro lnForc.1n5 eb•l . "'"'"''' c.onPorm to AC:.I 615. . I':'.F'• .-,·:d;: ac:c:ouorle& n"c.euary to prop .. rly &upport r"lnlorc ln g aL tho po&ltlon& e>hol'tn on the doc:um..,.,:&. 1 .Calc:lvm c:h lorlde or adml><turo& c.ontolnlng more than 0.05>'6 c.h k>rldo lone or thloc.yonatee ore not permitted. e.Do not. p loc.e plpoe, Cluc.t& or c:ha&e& In etruc.tural c.onc.rek ,. :·.·•aut prlc~ approval oP the Struc.turol l:nslneer. NOTE, THE SAI'j C.UTTIN<& 5HALJ.. 6E DONE l'jiTHIN :24 HOURS TO PREVENT UNCON~LLED CRACKIN6 OF THE SLAe AND ~N THE CONC~TE HAS HARDENED SU!"FICIENTL. "( TO PE~IT CUTTIN6 Y'<ITHO\IT CHIPPIN6, SPAL.LIN6, OR TEARIN6. TYPICAL SAWCUT JOINT 1-004 CONT. EA. SID!!! OF' JT. TYPICAL CONSTRUC TION JOINT LOCATE UNDI!!R PARTITION VjHEN P05SI6LE TYPICAL CONC SLAB ON GRADE DTL'S INTERIOR SLAeS-ON-~AAPE ( S.O .~. ) I. UNLESS NOTED OTHE~I 5e, INTEI'I.IORS S.O.<!'I.'S 5HAL.L 6E ,. THICK CONCI'I.ETE SLA65 Pl.ACED ON A MINIMUM 4 ' THICK LAYER Of' FI'I.EI:-DAAININ6 6RAVI!L. :2 . AU.. INTERIOR S.O.S .'S 5HAL.l.. 6E I'I.EINFORCI:OD l'jiTH 6•6-Y'!I.4MI'jl.4 I'El..DED I"'II'I.E f'A6RIC UNLeSS NOTED OTHERI'ii5E. !l. PROV IDE SLAe CON~L JOINTS MAXIMUM 15' eACH I"!AY, UNLESS NOTED OTHEI'IY'<ISI: ( SEE TYl"ICAL DETAILS ). 4 . ~VIDE FREE-DAAININ6 ~RAVELS AND COMPACTED FILL ( i'IHEI'I.E NECESSARY ) ACCOI'WIN6 TO SOILS I!N61NEeR'S ~COMMENDATIONS . 5 . COMPACTIVE EFI"ORT FOR ~RAVELS, STIWC.'T\JFlAL. FILL AND r.XISTIN6 SUEl6AAPES VjHICH SUPPORT S.O.S .'S SHAl-L 6E IN ACc.OI'lDANGo!j, Vj i TI-' SOILS EN61NEER'S I'I.EC.OMMI!!NDATIONS. •o~. I ' . 6A5E ANC:.LE i ATTACHHENT- 5EE HETAL 6UILDINC:. HFR TYPICAL c:;RADE }1- V'IALL REINF . (2)-#5 CONT . T $ 6 0 114 ill 1::2" o.c.. --~-+ 114 VERT. ® 16" O.C. --.~.._, Drt. •4 x 26 "1 r 10 , 0 16 ' o.c.. $100'-Q' S.O.cS-SEE TYP. DETAIL 1\._-l--CONT Ac. T LAP • • ROUc:;HEN COLD JT __.--, TO 1/4' AMPLITIJDE -TYP ~~--~------+---~'--+-~·~--· 9 " 1 ~~ = 1,_0 u Di't. FROM FTC:, 115 x FULL HTl.<IO ' (6 THUS) 1.1/2' CLR ALL AROJND b" 6 " .2-115 CONT. OF • 9 liS HORIZ CLOSED TIE - SPAc.E AS FOL.LOriS: 9 -#9 0 4" O.C.. o TOP OF PILASTER -~ o 10" O.C. FOR 6ALANCE PLAN VIEV'i @ -----c , .. = ,._0 .. DY'IL. 114 X 16 "fC'I6" ® .24" o.c . • --X--)( $100'-0' PL~IV EXTERIOR SURFACE • SEE PLAN PFi.-?V I.'J E :!o /4' dla x II" 4 , l e>~'l...:'9" ANC.HOR I ----1~~:..._---,Ji 60L T5-TYP o r PILASTER:> PROV IriE (2)-•5 x 10' HORIZ I HOOK ' Di"'L ~ FROM "ILASTER TO 1'E'lSION TIE __ LI_I_ I I I I I I I I ---r---r------1--1. I I I I • I I I I ----~-1-'=~ I I I I I I ----~--r ROUC:.HEN COLD JOINT TO 1/4" AHPLITUDE-TYP. 10" "----.2-115 CONT. =NC.L05E ANCHOR 60L T5 I'll (9)-#9 x[J'HORIZ TIES 0 4 '' o.c.. ~~i~; NOT 5HOY'lN) • cl • • ~1111 11 :2'-611 CONTACT LAP • 5/e" THI< A5PHAL T IMPREcSNATED FI6ER 60ARD-TYP 100'-0' I _]_--._ PILASTER REINF • DV'll. '5 SEE C/51 v'IALI-REINF ' $ DY'll-- ~·EE A/51 • I I I ----1--t. I I I • en eu V'IALL I • b I ! . PILASTEf". 6!:YOND 2'-411 (2)-115 COt-IT + (9!-115 x 9'-e" SPACE AS 5HOI'iN (4J-•s x :l'-4' TRANSVERSE 0 12' o.c. 1"--=-1'--0-.. -----------------® KURTZ ~ ASSOC. I A TES I INC.. 5012 C.OUNTY RD. 154 cSrLENY'lOOD 5F'RINcSr5, C.OLORADO ('110) '145-b905 Con >-..4-Wo.z ..,~., G c; 'r-"'tZC...-, - D). 'f C ~( ~ o<>.J-(I r C/GV)C.U"'o !._ DRAY'lN BY: H.H.Y'l . C.HEC.KED BY: B.J.K. 5C.ALE: A5 5HOY'lN PROJEC-T NO.: 05-11.1 DATE: C.ON5TRUC.TION 5ET: 04/19/01 5HEET TITLE: cSrENERAL NOTE5 $ FOUNDATION DETAILS 5HEET: S= I • -. : •• BUILDER: KDM BUILDERS CUSTOMER: $9 0 9 2 '? 'S IIIli LOCATION: ?RII Eli lb & WIDTH LENGTH Bldg A : 40.00 6o .oo Roof Sheeting : Type: cs Gage: 26 Color: Eme rald Green Finish : Kyn ar Wall Sheeting : Type: AP Con~-~ Wo:;'f'le"' Ill liilaiiiSI IIIII! SWA HEIGHT 17 .00 FRONT ROOF PITCH 2.000 Ordered Options: DOWNSPOUT DROPB-SWA 4 Base Condition: Base C w/ trim Base Trim Co lor: Parchment Wall Mastic: No UL Rating : 90 Thermal Blocks: N/a DOWNSPOUT · DROPB-SWC 4 . TABLE OF CONTENTS GENERAL INFORMJ>,TION ANCHOR ROC PLAN A1-A2 CROSS SECTION CS1-CS1 ROOF FRAMING RE1-Rf1 ROOF SHEETING CS1-CS1 SIDEWALL S1-S2 ENDWALL E1-E2 UPDATED DETAILS __ _ QUALITY ASSURANCE P DLICY __ _ Framing Kits & Wall Openir,gs See Accessory Schedule on Anc11 or Rod Plan, Page A 1. rZ:J ~--------------~----~~~,~~~ I 1&~ ,.fll ~~~ See. Load Notes on Anchor Ro d Detail !" ~: _, c B BUILDING 'A' D A KEY PLAN PURLINS/GIRTS 50" LIP . Gage : 26 ~--------------~7·--~~~~L-----------------~ I. Color: Parc hm ent Finish : Kyn ar Framing: Purlin Type: Zee s · Girt Type: Cees Sidewall Eave Trim Type: Eave Gutter Eave & Gable Trim Color: Emerald Green Downspout Type: Closed Downspout Color: Parchment Elbows at Bottom of Drops : Yes Corner Trim Color: Emerald Green Framed Opening Trim Color: Emerald Green Light Transmitting Panels: o c, .. rvt::J .. , 0~ ·o ________________ ; ____ ~----------, L-----------~--------------------~---,--~----~S=H=E~==IN=G=n=P=ES=-------~~·~~~ _ : ___ :,_--------------------,-------------------~ lO:--=-=,.-J-"'=-::=-::~"-.=-==-==l-"_ . m;ElliN~ __ o_· _· __ --~ __ · _JillLj,jfjL ___ : _ '-___ c...· ME~LII!I!l ~ -_ 1-----STEEL LINE -= ----r--- ------~ ~ I ~ I l • J LTC Panel AP Panel CFW-PAN EL FSP·-PANEL MSC Panel ------------------------------------~-----------------·- . ',~ •, .. •'··' JUNClOR • TEMP003 .TIF -41212007-07 :~5 . ; . . ~~:·,-. DESIGNAtiON D B DESIGNATION D B 816 6.00 3.00 . 818 8.00 814 8.00 3.00 814 8.00 ·2.&i- 812 8 .00 3.00 812 8.00 2.150 ' 1014 10.00 3.150 1014 10.00 2.75 2.75 -1012 10.00 .__ ____ ..___ __ 3.50 1012 10.00 ~tng081~"==--~-----·---------,--~---'---~----j 1 Drawing . . . 1 .• a) Drawings stamped 'PERMIT DRAWING<!" •m drawing• tho : · ""' complete for Uoe moat ·plllt. howewr, Iince oume delalla and part marks ora nilulng, they ara pnollmJnary and are not to be uaed for conatruction and are not conlldarad final drawlngo. b) Drawingo atomped "PROGRESS DRAWINGS" are dnl>~i ngs that ara complete for the moat part, however, since aorr . J detalla and part marka are mlallng, they are prellmlnlll) and are not to be uaad for conatrucllon and are not conalderad final drawings. c) Drewlnga stamped "DOCUMENTS FOR APPROVAL" ora ,·' . prallminaty drawings, uaad far approval with no part markings and ora not to be u&ad for construcllall . tJ S'e-::;;.4-VL. r'/0' '1t~..,.-{; w bu.t/cllvur fZet:tu.trtwt-evL 1-5 , fttl H1qk 5-l-rtittlf lA BtJ/11~ (Zhy:utre5 5peaA-l,lt1spe&-/d / -tWfmtff ,tff'1ZOVK"L I (/tfe.r-ttf ROOF PANEL MANUAL V --------- APPROVED I N ~ ,_ .... • Q .... • Q) w ~ ...J a! 60'-0" :20 '-0" :20 '-0" :20 '-0" ~4" ~ ~ 4" u'-e" ' 5 '-4" r D \ I r D \ I 5'-4" " J'-e"" e" Jl' (6\ \.?Y fA\ \.?J} (6\ '-e" \ 51 ) ;-1. :.l'-0 ' .,2'-0" ~ , ~J7 ;-~· :2'-G' ..2'-0" L \._5)-/ O" Tl'i = 100'-0"--...;::~ r-TI'i" 10 0 '-0" \ J -~!----~ '{" \ J ri----~ Tl'i = 100'-0"~ /-Tl'i = 100'-.-~--1---'-+-~ -. . -\ --- - -., .,- 1->.,--''<--~~. • ~--~1411 ff • I, • / • II>IF_-~ . d-1 • ~---1<--{ ~ '? I I +--TI'i = -+--u(\ -r-I ?."" -11' r -+-f-c r-I 7. . -t -+-Tl'i = -r-I I -:!..,,; ,..... _j '-'1'1 '-4" I T •1 "" <!) I 1-. _I "" ~ I '1'1'-4" '--L , 1,1:!!: I I -Lf-_1_ j_ _j 9 i r-_1_ j_ _j 9 =-'-lL l Jl. I ~ r-I ,_ I I -· '--I I -= d-1 I :I I I I I I I I I ~ ll I <!) I 'I : l l : fZ\ l l co~~~ ll I 4 '!.._, l! ·-4" 1 1 1 1 1 1 \2!) 1 1 1 1 ~ "' ~,i; ~ 4·~-1J 1--4 " e "~ll 11 I I I I I I I I I ~I z · al ~ , I : I '1'1'-4" I I ~I : : I '1'1 '-4" I : I I 1 1 ITI'i = ~ : I : ~1, .b T.O . 5LA6 II I II 1 ,. Tl'i =LI' I -+---t;iVlloo'-o" ~I I I 'f 100'-0" loo'-O"I'tz; .--7"'. '!<- ! II"' ~~ Ill I : : I : : I OPP051TE(C\ ~ l''o I ! -:::.. k-----,-J~ -l'-59 I I I I I I I HAND\ 59/ -1-h~-----=-· + "f" -5AI'i -CUT CONTROL. JOINT ~ L 1--1---'k-! -~, 8--·------:-·.-·--·----·-r:-----·--·--:---·-----·-rt------·-·-·-:-·-------L r-,--~-=~~'1\-- ::..~-::'k--··-~ ~l .r ~II : O : : : : l : 0 "• ~ ~ '---~--"1<- 1 I ~e" 1 1 I I I I : I : 1 e·;J I I :I I : I : I I I I I: I . i I I I I I I I' (6\ I :1 I ; I I I I ~ I I I IJ I (6\ • 9 Cl N \2!) I Jl I i I :II @ I ~ : ,J I I I IJ I \2]) 9 9 · I ~~~·-4.. : ! i i : J J : "~~4~011, I ~ ~ g ! I 1,1 I I I I I I I I I " I I I I Ill I 1'-4 "d 1'-4"r'i:' II. I FT<:> 1 11 I I I ~ I I I I FT<:> 'I i ., I TF = '16 '-e " · I I f '-' \ I I TF = I r TYP All.. I I I \2!) I I I I '16'-e"-I I AROUND ! I . I 6" I I I 6" ! TYP All.. """ I' I II I 4 I ~ I AROUND'\ I d-1 t>k----11 t;l L i -cr + + -::h 9 I c-I + + -::h 9 i J fa ii-----'I<,Y -"k----4--l I -~TI'i = I 9 II T ; ,_ 9 II T I Tl'i =~-IJ I f-1-1---+ -"' '1'1'-4" -r--'t . --'1'1'-4" ; ~ d;) • I L ---- -+----I L ~r--~ <"""" --1-1--- -I L -~~-----+ ---_ -r-_j I ~ d-1 \->~..--'"-~ <!) ~ ~ --I<! ... • • ~ ~ ' l' ~ _j_ -'"' .,--"<;----"<--1 l'i-"'= 100'-0"~t;f-.--/i'B;:::: -,.-'\:::'TI'i .. 100'-0" L ' -r; :r~ f-·' r I _._ -r Tl'i = 100'-o'J -r-/E6~--\::~TI'i = 100 '-0 " T { t ;~ \ ~ I' 1;2'-0" :.2'-G"i L '<t <!) (A\ '<t 1..2'-0" :.l'-0'1 L { ~;;> \ \ S l J ·1 r~ \ 51 ; 1 r \2!) '.J '-e" ~.. LP~ ~ (D'\ 5'-4" u·-e" 1-f'--'e::....," Y,j<,.,!o;l~4.-. -'--..,r :zo'-o" 1 \2!) :zo'-O " 1 \2.!) :zo '-o" 4 " ~ e " -~ 60'-0 " 2 FOUNDATION PLAN 1/4"=1'-0" Pl.. AN NORTH EB KURTZ $ ASSOCIATES, INC. 5012 COUNTY RD . 154 CS.LENY'IOOD SPRINCS.S, COLORADO ('110) '145-6905 TI~E !3HDI F9Fl S/cl ~8E~!3 i"Re'e!JIE£114~ 1'1iiT AIFbs£ It 'ii'U IT I"! 1i tb 17 ;' tl"!l t CS.ARF:'IELD COUNTY, COLORADO DRAY'jN ElY: H.M .Y'j. CHEC-KED ElY: El.J.K. SCALE: A5 SHOY'jN PROJECT NO.: 05-11.1 DATE: CONSTRUCTION SET: 04/19/01 SHEET TITLE: FOUNDATION PLAN SHEET: S=2 V'I.V'I.F.-SEE l TYPIC.AL DETAIL I \ ' l ~ ~~-x--~-~--->~-~-~•? . ..: "" f----.. h-===-=,= 2-115 CONT J (5T~~ER 5PLICE5J! Sl.JPPORT 13Af't, 114 I® 4'-0" o .c.. b" b" I 6" ~LEAR I I ViALL REINF)} { r.1 { 1'-e" b " 1,_2 .. DV'IL FROM FT~ C.ENTE:RLINEIJ<..-:=--.,~<--:..-=:__ /--:::~liS x FULL HTI..c-10" C.OLUMNf / (6 THUS) / ----'.-ro~-1--r~li\<' 1.1/2" C.LR[ .1$:11 6 SIDES[ I (l re 0 \ 0 ~ I - C.ORNER. 6AR., 114 X 60" X 60" ® 12" o.c. l e" l ~p~~.~=:'-~-~o-~~. ~IE~~-----------------1-V'IAL ___ L_1 _______ ~ eu en ' 116 HORIZ Ia\ /1-C.LOSED TIE ViALL REINF"'""'V~ ® 10" O.C.. ~ '--..~~-.., ---"~<:- = -!) o---~~ DV'IL FROM FT~ V.>i\i:~ ___ '4'l,. -t-----',"'1 ~ liS x FULL HT !fiO"I-- (4 THUS) • 1.1/2' CLR ALL AROUND PLANVIE~ @) ----c 111 = 1•-ou KURTZ 4 ASSOC. I A TES I INC.. 501.2 C.OUNTY RD. 154 ~LENV'IOOD SPRIN~S, C.OLORADO (<110) '145-b905 ••II"!! SAD P ' FS'fiil: i/J lOERa ·--·· •' i i'if 't 1 a -"''""' ·---. ,..., ,...,,_.. 5ARFIELD c-OUNTY, C.OLORADO DRAV'IN 6Y: H.M.V'I. C.HEC.KED 6Y: 6.J.K. SC.ALE: AS SHOV'IN PROJEC.T NO.: 05-11.1 DATE: C.ONSTRUC. TION SET: 04/19/01 SHEET TITLE: DETAILS SHEET: S=3 • .-.... __ ----· CQIJNTY PI :q NQIES ___.--.....-----~;:: GABOSSI EXEMPT~ON PLAf A Tract of Land Being Situated in the NW1f11 of Section 35 Township 5 South, Range 90 West oi tJJie 6th P.M. County of Garfield, State ot; Colorado 'POINT Of BEUINNING -LOT 2' No~th 1/4 CornPr of Section 35. round 2• Iron Pipe a.nd Alul'l. Cg,p, PLS 15710. ' '.· ..... · 346 315 331 -. 311 . ' • r \"·-----... . ' .... 0 ~y;l !> lndic:o:tes rounti or Set Rebo r \1 .1 Plostic Cnp. PLS No. 27613 <Typic:n t QU cor"nel"'s unless othrr"'wl se noted.) Vicinify Hap (.:Jpt tg Sc ole '. t.----____ , GLENWOOD SPRINGS D ALL !RRIGA TION DITCHES AND DITCH EASEMENTS ARE TO BE RECOGNIZED AND MAINTAINED AS EXISTING AND IN PLACE. IN THE USUAL HANNER. ·'POINT OF BEGINNING -LOT I' LEGAL DESCRIPTION LOT 1 LEGAL DESCRIPTION LDT 2 2> ONE (J) DOG VILL BE ALLOVED F'OR EACH RESIDENTIAL UNIT VITHIN THE SUBDIVISION EXEMPTION. 3> CONTROL Of NOXIOUS IJEEDS SHALL BE THE RESPONSIBILITY OF THE PROPERTY OVNER. 4) NO NEll OPEN HEARTH SOLID-fUEL FIREPLACES VILL BE ALLOVED ANYVHER£ VITHIN THE SUBDIVISION. ONE (!) NEV SOLID-FUEL BURNING STOVE AS DEFINED BY CRS 25-7-407 ET. SEll. AND THE REGULATIONS PROMULGATED THEREUNDER. VILL BE ALLOIJED IN ANY DVELLING UNIT. ALL DIJELLING UNITS VILL BE ALLOVED AN UNRESTRICTED NUMBER OF NATURAL GAS BURNING STOVES AND APPLIANCES . . ln'i0D \,on Dit c h JnUico·t.<~~ llitc::l"l on() DoLch Ac.ces s/Mu;ntenance E c.l.~;l'r1<'11 t !:.. 5) ALL EXTERIOR LIGHTING SHALL BE THE MINIMUM AMOUNT NECESSARY AND THAT ALL EXTERIOR LIGHTING BE DIRECTED INIJARD. TOVARDS THE INTERIOR OF THE SUBDIVISION. EXCEPT THAT PROVISIONS HAY BE MADE TO ALLOIJ FOR SAFETY LIGHTING THAT GOES BEYOND THE PROPERTY BOUNDARIES. COUNTY SURVEYOR'S CERTIFICATE N35'15'1~'1J 161.50' ~ ' . \ Lot 1 890,802 sq.ft. 20.220 acres APPROVED FOR CONTENT AND fORM ONLY AND NOT THE ACCURACY Of SURVEY~ CALCULATIONS OR DRAFTING. PURSUANT TO C.R.S . :i8-51·101 et. seq. BY• ·nE"P"ufv-d".\R"fii:i.1fcC:iuNTI's"liR-vE'v6R" ____ _ DA TE•----_____ ----_ ---_ ---__ ---_ ---_ StlRVEXDR'S CERTIEICA!f L SAMUEL D. PHELPS, DO HEREBY CERTIFY THAT I AM A REGISTERED LAND SURVEYOR LICENSED UNDER THE LAVS OF THE STATE Or C0£0RADO. THAT ->fHIS PLAT IS A TRUE. CORRECT AND COMPLETE PLAT or THE • GABOSSI SUBDIVISION EXEMPTION PLAT', COUNTY OF GARF!ELIL STATE or COLORADO. AS LAID OUT, PLATTED, DEDICATED AND SHOIJN HEREON. THAT SUCH PLAT IJAS MADE rROM AN ACCURATE SURVEY OF SAID PROPERTY BY ME AND UNDER MY SUPERVISION AND CORRECTLY SHOIJS THe' lOCATION AND D!MENSICNS OF THE LOTS, EASEMENTS AND STREETS Of SAID SUBDIVISION AS THE SAME ARE STAKED UPON , THE GROUND IN COMPLIANCE 'JITH APPLICABLE REGULA! IONS GOVERNING THE SUBDIVISION OF LAND. IN VITNESS \/HEREO F I HAVE SET MY HAND AND SEAL THIS __________ DAY OF----"----------------A.D. 2001. BY• SAMUEL D, PHELPS COLORADO REGISTERED PROFESSIONAL LAND SURVEYOR M 27613 fOR AND ON BEHALF' Of' SURVCQ. INC. SIW&1J>S - Dltck Croa541'5 I0\.0 PrOPf"ty NO. 8Y DATE P.EVISION DESCRIPTION L.ot 1.510.900 34.685 L.ot3 136,553 sq.f't. 3.13 acres 1SlD111t 17.37t:i acrea SURVEYORS• NOTES• Center/Nor:"th 1'16 Corner"" Sefition 35. F'ou 1d Reba.r ·lo'/2' A1u~. Cop, PLS 15710 Ovhd. Utility Line to Adjoining Pl"'ope,..ty. Inttlc:c.tes Appa.rent Ea.seMent I> BEARINGS AS SHOVN HEREON ARE BASED UPON A RECORD BEARING OF N.89'42'00'V. FOR THE EAST /VEST CENTERLINE OF SECTION 35. .. --- MONUMENTATION BEING FOUND IN THE f"IELD AT EACH END or THIS LINE IS A BLM ALUM CAP AND STANDARD MONUMENT. 2> THIS PROP!i:RTY IS SUBJECT TO MINERAL RIGHT RESERVATIONS AND RIGHT OF \JAY FOR DITCHES AND CANALS CONSTRUCTED BY THE AUTHORITY OF THE UNITED STATES AS RESERVED IN PATENT RECORDED OCT. 06, 1967 IN BOOK 399 AT PAGE 311. 3> THE BOUNDARY DIMENSIONS AND LOCATIONS roR THE SUBJECT PROPERTY AS SHOVN HEREON ARE BASED UPON A PREVIOUS MONUMENTED LAND SURVEY AS PREPARED BY SCARRO'J AND 1/ALKER. INC. AND BEING DATED SEPT. 06. 1993. 4) THE LOCATION OF THE IRRIGATION DITCHES SHOIJN HERE~N ARE SCALED IN PART FROM USGS QUAD MAP OF THE SUBJECT PROPERTY AND ARE APPROXIMATE. THE IRRIGATION DITCHES CROSSING THE SUBJECT PROPERTY INDICATE EASEMENTS OF UNSPECIFIED VIDTH FOR MAINTENANCE. THIS EASEMENT MAY INCLUDE ACCESS OVER AND ACCROSS THE SUBJECT PROPERTY TO THE DITCH. 5> THE 20' 'JIDE PUBLIC SERVICE EASEMENT SHOVN HEREON IS BASED UPON UNRECORDED EASEMENT DOCUMENTS PRESENTED TO THIS LAND SURVEYOR BY THE CLIENT. NOIICE1 ACCORDING TO COLORADO LAV YOU MUST COMMENCE ANY LEGAL ACTION BASED UPON ANY DEFECT IN THIS SURVEY VITHIN THREE YEARS Af"TER YOU fiRST DISCOVER SUCH DErECT . IN NO EVENT , MAY ANY ACTION BASED UPON ANY DEfECT IN THIS SURVEY BE COMMENCED MORE THAN TEN YEARS FROM THE DATE or CERTIF'ICATION SHOVN HEREON. . ·- • \ A TRACT Of LAND SITUATED IN THE NVI/4 OF' SECTION 35, TOIJNSHIP o SOUTH. RANGE 90 VEST DF' THE 6TH P .M. COUNTY OF' GARfiELn. SiATE OF COLORADO. SAID TRACT OF LAND BEING MORE PARTICULARLY C SCRIBED BV METES AND BOUNDS AS FOLLOVSo BEGINNING AT A POINT FROM VHICH THE NORTH 1/4 CORNER OF SAID ~ EC1 :O N 35 BEARS N.45'21'31'E. 655.56 fEET, SAID NORTH 1/4 CORNER BEING A IRON PIPE IJITH AN ALUMINUM CAP, PLS NO. 15710, THENCE S.26'31'06'(. 55.72 FEET; THENCE S.26'11'52'1J . 62.99 FEET; THENCE S.U'39'34'V. 51.69 FEET1 THENCE S.37'29'23'.V. 90.15 FEET1 THENCE S.49'48'42'V. 66.45 FEET1 THENCE S.22'37'!4'V. 167.65 FEET1 THENCE S.04'15"08'E. 209.64 FEETi THENCE S.40'24'52'V. 63.16 fEET1 THENCE S.23'42'17'1J . 160.96 rEETi THENCE S.34'01'36'V. 250.32 f :ETJ THENCE S.28'03'51'E. 69.80 fEET1 THENCE S.02'36'42'V. 276.57 FEET TO A POINT ON THE NORTHERLY RIGHT Of 'JAY OF STATE HIGHVAY 6 AND 241 THENCE ALONu SAID RIGHT OF 'JAY THE FOLLOIJING 5 COURSES • I> THENCE 358.13 FEET ALONG THE ARC OF A CURVE TO THE LEFT HAVING A RADIUS OF 2010.00 FEET, A CENTRAL ANGLE OF 10 '12'31' AND SUB - TENDING A CHORD VHICH BEARS N.72'17'01'V. 357.65 FEETJ 2l THENCE S.1 3'12'00'\J. 50.00 FEETJ 3l THENCE 270.72 FEET ALONG THE ARC Or A NON-TANGENT CURVE TO THE LEFT HAVING A RADIUS OF 1960.00 FEET. A CENTRAL ANGLE OF 07'54'49' AND SUB-TENDING A CHORD VHICH BEARS N.61"21'35'V. 270.50 F((T; 4) THENCE N.B5'19'00'V. 368.00 FEET1 5l THENCE 109.74 FEET ALONG THE ARC Of A CURVE TO THE RiGHT HAVING A RADIUS OF 5680.00 fEET, A CENTRAL ANGLE Of 01'06'25' AND SUB- TENDING A CHORD VHICH BEARS N.84'45'48'V. 109 ~74 FEETi • THENCE DEPARTING · SAID RIGHT OF \JAY N.23'00'10'E. 85.51 FEET) THENCE N.33'41'22'E. 273.31 FEET1 THENCE N.10'4l 'Ol'E . 126.20 f"EETJ THENCE N.18'00'46'E. 102.71 FEET; THENCE S.79'05'06'E. 44 .2:5 FEET; THENCE N.87'14'09'E. 373.76 FEET1 THENCE S.83'55'42'E. 116.11 rEETl THENCE 1'1.45'21'31'£. 1000.98 FEET TO THE ~OINT OF BEGINNING. SAID TRACT OF LAND CONTAINS 20.2ZO ACRES . MORE OR LESS. LEGAL DESCRIPTION LOT 3 ' A TRACT Of LAND SITUATED IN THE NVI/4 OF SECTION 35. TOVNSHIP 5 SOUTH. RANuE 90 VEST OF THE 6TH P.M. COUNTY OF GARFIELD. STATE OF COLORADO. SAID TRACT OF LAND BEING MORE PARTICULARLY DESCRIBED AS FOLLOIJS• BEGINNING AT A POINT FROM IJHICH THE N1/4 CORNER Of SAID SECTION 3 5 BEARS N.I0'07'06'E. 1~44.83 FEET, SAID POINT BEING AN IRON PIPE 'JITH AN ALUMINUM CAP, PLS NO. 15710J THENCE S.24'46'00'\J. 324.52 FEET TO A POINT ON THE NORTHERLY RIGHT OF VAY Or STATE HIGHVAY 6 AND 241 THENCE ALONG SAID RIGHT OF \JAY N.6 5'14'00'V. 504 .04 rEET; THENCE • CONTINUING ALONG SAID RIGHT OF VA{ 68.27 FEET ALONG THE •'RC Of A CURVE .,TO THE LEtT HAVING A RADIUS OF 2 <HO .OO FEET, A CENTRAL ANGLE OF 01'56'46' AND SUB-TENDING A CHORD WHICH BEARS N.66'12 '33'V . 68.27 rEET1 THENCE DEPARTING SAID RIGHT Of VAY N.02'38'42'E. 134 .32 fEETi THENCE S.80'11'5l'E. 128.20 FEET; THENCE N.72'59'26'E. 101.15 FEET; THENCE S.68'43'16'E . 110.56 fEET1 THENCE S74'56'17'E. 210 .39 F EETi THENCE N.84'18'28'E. 105.41 fEETJ THENCE S.84'08'51'E. 15 .86 FEET TO THE POINT OF BEGINNING. SAID TRACT or L AND CONTAINS 136,5 53 SQ.FT. OR 3.1 3 ACRES . MORE OR LESS . EXEMPTION CEBT!EICATE THIS PLAT APPROVED BY RESOLUTION OF THE BOARD OF COUNTY COMMISSIONERS AT GARFIELD COUNTY, COLORADO THIS ••••••• DAY OF -------~-------• A.D. 2001. IN fiLING VlTH THE CLERK AND RECORDER Of GARfiELD COUNIY. SUCH APPROVAL IN NO VAY IMPLIES THA T THE INFORMATION SHOIJN HEREIN IS TRUE AND ACCURATE BUT DOES INDICATE THAT THIS PLAT IS EXEMPT FROM AND NOT SUBJECT TO REGULATION UNDER GARfiELD COUNTY SUBDIVISION REGULATIONS AT THE TIME OF ITS FILING. CHAIRMAN 'JITNESS HY HAND AND SEAL OF THE COUNTY OF GARFIELD . ATTESTI _____________________ --------- COUNTY CLERK '•,'' A TRACT OF LAND SITUATED IN THO: NVl/4 Of SECTION 35. TOIJNSHIP 5 SOUTH_ RANGE 90 \JEST OF THE 6TH P.M. COUNTY OF GARFIELD, STATE OF COLORADO. SAID TRACT OF L AND BEtNC MORE PARTIC ULA RLY DESCRIBED AS F"OLLOIJS• BE.GINNING AT THE Nl/4 CORNER 0 1' SAID SECTION 35. SAID POINT BEING AN IRON PIPE VITH AN ALUMINUM CAP, PL S NO . 157101 THENCE ALONG THE EAST LINE Of SAID NVl/4 S.07'03'10'E. 1870 .02 FEET, THENCE DEPARTING SAID \JEST LINE N.90'00'00'V. 84 .81 rEETJ THENCE S.00'40"50'1J . 80.42 FEETJ THENCE S-10'10'24'(. 123.46 rEETJ THENCE S.79'49'36'1J . 85.70 FEET; THENCE N.59'20'18'V. 80.34 FE ET 1 THENCE 19.34 fEET ALONG THE ARC Of-A CURVE TO T nE LEFT HAV !NG A RA DIUS Of 35.00 FEET. A CENTRAL ANGLE OF 31'39'4 2' AND SUB-TENDING A CHO RD IJHICH BEARS N.74'10"09''J. 19.1 0 fEETv THENCE N.90'00'W'J. 38.18 FEE!i THENCE 89.09 FE o:T 'LONG THE ARC OF A CURVE TO THE RI GHT HAVING A RADIUS OF 515.00 FEET, ol CE •TRAL ANGLE OF 0~'47'59" AND SUB-TENDING A CHORD VHICH BEARS N.85'06 I 'll. 7.99 FEE T; THENCE N.80'12'0 1 'II. >.76 EET; THENCE 110.42 FEET I ONG rH E ARC OF A CUR VE TO THE RIGHT HAVING A RADIUS Of 65.0 0 fEE A ( NTRAL ANGLE [IF 97'20"08' AND SUBTENO!NG A CHORD VHICH BE 'RS 31'3 i7'V. 97.6Z rEJ:TJ THENCE N .94'0S'~1'1J. 19 .SO 'EET; THENCE ~ 84'18'28'11 . 105.41 FEET; TH£NCE _IU.4..!56"17'V.__l 0.3~-cEETJ THCN CE <68'43'16 '11. 110 .56 FEET; THENCE S.72'59'c6'1J .• OI.lo -'EET1 THENC~Ii -80'11'~1'11 . 128.20 FEET, i~~~g~ ~~~:~~:;~:~ ~~~-;~ ~~g; J~~~~E ~~:~~:?~:t ~~~-~~ !r.W' THE~CE N.40'24'52'E. 63.16 FEETJ TH ENCE N.04'15'0B'V . 209.64 FEE T1 THENCE N.22'37'14'(. 167.65 FEETi THENCE N.49'48'42 'E. 68.45 FEETJ THENCE N.37'29"c3'E. 80.1 5 f[ETJ THENCE N.!I'39'34'E. 5169 FEET ; THENCE N .?6'11 '~ ?'E. ;2.99 FEET; THENCE N.26'31'06'1J , 55.72 FEET 1 THENCE N.45 '2 1': 1'£. 355.56 FEE ·T TO THE POINT OF BEGINNING. SAID TRAC T lF L \NO CONTAINS L51D.900 SQ.FT . OR 34.685 -ACRES. MOR E - OR LESS. LEGAL DESCRIPTION LO T 4 A TRACT OF l AND SllUATED IN THC NIJ I/4 OF SECTIO N 35, TOVNSHIP 5 SOUTH. RANGE 90 VEST Of THE 6TH PM, COUNTY OF GARFIELD. STA TE OF COLORADO. SAID ·, RACT Of LAND BE ING MORE PARTICU L AR L Y DESCRIB ED AS fDLLOIJS• BEGINNING AT A POINT FROM IJHICH THE Nl/4 CORNER OF SAID SECTION 35 BEARS N.IO'D7'06'E. 1944 .93 fEE T, SAID POINT BEING AN IRON PIPE \liT H AN ALUMINUM CAP. PLS NO. 15710; THENCE $.24 '46 '00'\J . 324.52 FEET TO A POINT ON THE NORTHERLY RIGHT OF 'JAY Of STATE HIG H1,1AY 6 AND e4i TH ENC E ALONG SAID RIGHT or \JAY S.65'14'00'E, 254.18 FEET TO A POINT IJHICH INTERSECTS THE NORTHVESTERLY RIGHT Of" \JA Y OF GARFIELD COUNTY ROAD NO . 138J THENCE ALONG SAID NORTHVESTERLY RIGHT OF VAY THE FOLLOWING FOUR (4) COURSES • THENCE N.67'03 '2 1'E. 153.8 3 FEETi THENCE N.79'09"05'E. 64.99 FEET1 THENCE N.75•trl7•(. 119.64 F"EET i TH£NCE N.6B.56'19'(. 119..42 f'"EETJ THENCE DEPARTING SAID RIGHT OF 'JAY N.IO'IO'Z4'\I. 114 .23 r££T, THENCE S.79'49'36''J, 85.70 FEETi THENCE N.58'20'1 8'V. 80 .34 rEETJ THENCE 19.34 FEET ALONG THE ARC OF A CURVE TO THE LEFT HAVING ' RA DIUS OF 35.00 FEET, A -CENTR AL AN GLE OF 31'39'42' AND SUB-TENDING A CH [ RD VHICH BEARS N.74'10'09'V. 19.10 FEET1 THENCE N.90'00"00'1J . 38.18 FEET1 THENCE BB .08 FEET ALONG THE ARC OF A CURVE TO THE RIGHT HAVII<G A R,\DIUS or 515.00 fEET. A CENTRAL ANGLE · OF 09'47 '59' AND SUB-TENDING A CHORD IJHICH BEARS N.85'06'01''J. 87.9S FEET1 THENCE N.8D'I2'01'V. 56.76 FEET; THENCE 110-42 FEET ALONG THE AR C OF A CURVE TO THE RiGHT HAVINC, A RADIUS OF 65.00 FEET, A CENTRAL ANGLE OF 97'20"08' AND SUB-TENDIN G A CHORD IJHICH BEARS N.31'31'57'V. 97 .62 fEET1 THENCE N.64'08'51 '1J . 103 .94 FEET TO THE POINT OF BE GINNING . SAID TRACT OF LAND CONTA INS 149,257 SQ.FT. OR 3.4 3 ACRES. MORE OR LE SS. GAREIE! D COUNTY C! ERK AND RfCORDf!;·'S CERITEJCATE THIS PLAT IJAS FIL ED FOR RECORD IN THE OFFI CE OF THE CLERK AND l1EC ORDER OF GARFIELD COUNTY AT ----------O'CLOCK ___ M, ON THE -------___ DAY OF ----------------: ••• ~ A.D. 20 ____ AND IS DULY RECORDED IN olD OK -----PAGE ------RECEP ' ION NO. ______________ . -----------------------------------------CLERK AND RECORDER BY • ---!lE"P"ufv·----------------------· ------- "' • " ,; 0 a 0> I() 0 0> 0> ,---------------------------------------------------------------------{1~ ,_. .- SHEET 1 of 1 SaJrvCo'i Professional Land Surveyin£, Ser-vices 613 E. First Street , P.O. Box 3 26 New Castle, CO. 8164 7-082 3 Phone: (970) 984-9119 Fax: (9 70) 984 --3993 <S-"0 ?'' 3: 9 " Ul 3 "~ cSoENERAL 5TRJ.)G.l1JRAL NOTE5 cSoENERAL REGIJIFU:MENTS I. De61gn Ia based on the .:2009 edition oP the International Elvlld lng Code (leG). .:2 .Deslgn L ive Load•• a. RooP (5no.-t) .......... 40PSF b. !"!Ind .......................... '10 MPH 6ael~ ~"lind Speed, 9 ••~ond guet ~. OPPI~e Floo~ ......... 50P5F 9 .AII dlmene lone, elevations and detall6 on et~~tura l do~umente sha ll be ve~IP i ed against the ~~hlte~tu~a l do~umente p~lo~ to ~onet:ru~tlon or Pabrl~at l on. 4.The ~onva~t et:ru~tu~a l do~umente and epe~IP I ~atlone ~•p~eeent the ~ompleted evu~tu~e. ,.,., ~onva~tor shall p~ovlde all meaeu~es n•~••·~~ to p~ote~t the 6l:ru~tu~e and existin g adja~ent et:ru~tu~•• and utilities. S .C.Oo~d l nate a ll openlnge through Plo~e • .-tails and ~ooPe .-tlth Me~hanl~a l and c l e~V I~al C.Onv~to~. NotiP~ Engine•~ oP an~ openings to be ~ut In evu~tura l e~eteme. FOUNDATION5 !.Foundation deelgn Ia boeed upon the Pollo.-tlng aeeumed soli properties . Maximum Bearing c.apa~l~ ......................... 1000 P5F. ~t l ve 5oll Preeeure ..................................... 50 PCF. 5olle ~• preeumed to be non-expansive, non-eoluble, and not prone to ex~eeelve ~oneolldatlon . .:2.A II Pootlnge are to bear on und isturbed natural bearing material• or ~ompa~ted svu~tu~al Pill. 9 .Avold ex~eeelve .-~ettlng or d~lng oP the ex~avatlon, keeping the ex~avat lon ~eaeonabl~ Pree oP .-tater during pla~ement oP ~on~~ete Por Pootlng6. 4. 6a~lc.PIII on .-tails .-tlth Pill on both eldee to be ~ompa~ted In equal 11Pt6 ea~h a ide oP .-tall. CONCRETE AND REINFORCINcSo 5TEEL I.AII ~on~rete ehall attain 9/)00 P51 ~ompreeelve evength .-tlthln .:2e d~e ex~ept ae Pollo.-te. C.Onuete Por exterl~ Plat.-torlc. ond garage Ploore ehall attain 9,500 P51 ~omp~eeelve evength .-tlth ln .:2e da~•· :Z.U.e Type 1-11 Po~tland Cement (A5TM Cl50) .-tlth 4-6!11 air entrainment. Con~rete aggregate to be normal .-telght (etone). ::I .PerPorm all ~a•t-ln-pl~e ~oncrete .-tori< In a~~ordan~e .-tlth "5pe~IPI~atlone Por &Vu~tural Conuete Por Elvildlnge,' ACI 901-e4, un leee noted other.-tlse. Provide hot ~ ~old .-teather prote~tlon per ACI 905 or 906. 4.RelnPor~lng eteel shall ~onP~m to ASTM A615 o "4 and emaller ..... cSorade 40: 115 and l~ge~ ..... cSorade 60 S.Horlzontol ~elnPor~l ng etee l ehall be mOde ~ontlnuoue ~ lapping ~· a minimum oP 9:::! bar diameters at all epll~•• and providing ~omer ~.. Fabrl~atlon and lnetollatlon oP relnPor~lng eteel shall ~onPorm to ACI 915. 6.Provlde a~~e .. orlee ne~eeear~ to proper!~ euppo~t ~•lnPo~~lng at the poeltlone eho.-tn on the cfowments. 1.Cal~lum ~h l orlde or adm ixture• ~ontolnlng more than 0 .05SII ~hlorlde lone or thlo~yanatee a~• not permitted. e.Do not pi~• pipes, Clu~ta or ~ha••• In evu~tural ~on~~ete .-tlthout prior approval oP the St~~tural Engln•er. REINFORCED UNIT MASONRY I. 1'-faeonr~ unit deelgn, manuPoc;ture and lnetallatlon ehall c;onPorm to etanda~d• eet ~ the 1'-faeonr~ Institute oP Amerlc;o. :2 . ~sembled maeon~~ to develop 1500 PSI ultimate c;ompreeelve etrength (F 'm) In :26 do~•· Spec;lal lnepec;tlon not ~equl~ed. e. C.onc;rete maeon~y un ite ehall c;onPorm to ASTI'-f C.'IO, 6orade 'N,' Type I, llght~elght bloc;lo:.. 4 . 1-fortar enall be ~pe 'N' or 'S.' 1'-forta~ ehall attain 1eoo PSI c;ompreeelve strength ~lthln :2e da~e. 5. (5o~out ehall attain :2000 PSI c;omp~eeelve strength ~lthln :2e do~•· b . RelnPo~c;lng ba~• to be dePo~med ba~•. minimum ~leld strength " 40 KSI. Lap relnPo~c;lng ba~ epllc;ee 40 bar dlamete~s unless othe~.-tlse noted . DY'«.. FROM FT6 114 X FULL HTlL'IO" N (6 TH.!S) '" ',LL.L..tY ~ z • / < b77.: /: C/ '/, ~/ . / /: /: • I I e" J • • ' rl 60ND 61'-1 REINF :/, '{.£.1. • / '/ C/~ ~/ / ;. _, ~ 113 HORIZ CLOSED T IE- Y6 : ~ SPACE A5 FOLLO e" 5 -113 • 4' o.c. e TOP OF PILASTER -113 o 10 ' O.C. FOR 6ALA 6ASE A~LE 4 A TT AC.Hi'-IENT- SEE i'-IET AL BUILDING 1'-fFR TYPICAL GRADE ViALL REINF. BONO BM YV _.- (2)-114 CONT. 114 VERT. G1 :24" O.C.. Q e" C.MU ~L­ GROUT SOL ID-r--....- TYPIC.AL SEE PLAN' 9"C.LR SEE PLAN ~ 100'-0' DY'«.. 114 x 26 '1 f'IO' • 24" o.c. PROVIDE LADDER TYPE, STANDARD ~T. HORIZ JO INT REINF. G1 lb" O .C.., TYPIC.AL • () :2-115 C.ONT . ---~ .. -=-1'--0-.. ----------------------~~ II ' PROVIDE 3/4' dla x le"lr'9" ANCHOR SOL TS-TYP Gl 1---'--~ PILASTERS 4" I I I I .j...l-1-- 1 I I I DY'IL 114 x lb"[Cio" ~ :24" o.c.. EXTERIOR SURFAC.E 9"C.l..R • -x-x--x • • • • Cl ~ 100'-0" ~ T~• '1'1'-4_" ____ __ 11f'!:e pV11/Vkf ;tta~l-~/./1'17 ~e ~,?" H/~ ,helcl 5d<>r /hf;; /#J.If't£!?P7/1, :2 -liS C.ONT. _J,.--re" ~L SEE PLAN ---~ .. -=-1-'-0-.. ----------------------~~ APPROVED SUBJECT TO NOI'ED EXCEPTIONS & INSPECTIONS ENCLOSE ANCHOR SOL T5 I'V (:2)-119 x[jHORIZ TIES • e" o .c.. 3/e" .THK ASPHALT IMPRE(5oNATED FIBER SOARD-TYP S .O.G .- (REINF NOT SHOY'IN) ' 4 ' • ------ 100'-o' GARFIELD COUNTY ~~EPAR~ ozo Z> By~~a.~a;.:::;_- LDCOPY J(() INSPECTION wrrHOVT 'JilES!. PLANS ON SITE of 14 ( 5~-.-.e~ DePTH )• 1.11,.' NOTEo THE SA.-! GIJTTIN6 SHALL eE DONE ~I THIN :24 ~TO PREVI:NT UNCONTROU..!:D CfVoei<IN6 Of' THe ~ AND ~N THE c;oNc;I'Um: HAS HAIW!:NED ~IC i eNT\.. Y' TO roeRMIT GVTTIN6 ~ITHOIJT (;HII"P IN6, SPALL IN6 , OR TEARIN<!o. TYPICAL SAWCUT JOINT F==ooo+::-+ ""'1 T I -I -------- PROV IDE (5)-114 x 10 ' HORIZ r-- HOOK I DY'«.. 'S FROM PILASTER TO TENS ION TIE I I I I n-r-r .... I'-I I I I I I I I I ::2'-b" C.ONTAC.T LAP 1'-o· 1-"'' c.oNT. !:A. SIDE Of' JT. ~L REINF 4 Dli'\L.- SEE A/51 I •~-+----TYP IC AL CONSTRUCTION JOINT ,. (, 1 I BEYOND :2'-411 (4)-115 X 3'-4' 'I'RANSVERSE 0 12" o.c.. l.Oc.ATE UND!:R PARTITION ~N POSSI6U: TYPICAL CONC SLAB ON GRADE DTL'S INTERIOR 5LA85-0N-6~ ( 5.0.6. ) I. UNU:SS NOTED OTHERI'IJ&e, INTERIORS S.0.6 .'S 5HAL.L. eE 5' THic;l< (;ONc;Rf:TE SLABS PLAC.E:D ON A M1N IIo1\JM ,., THic;l< !..A 'fER OF FI'I.Ee:-DAAIN IN6 6AAVI:L. :2. ALL INTER IOI'I. S.0 .6.'S SHAI..L 6!: RI:INF'ORC!:D I"!ITH 6x6-~1.4x~l .... fi'IE:LDE:D ~IRE: f'Aei'I.IC UNU:SS NOT'!:O OTHERI'IJ&e. 5. PI'WVIDI! SL.Ae c;oNTROL JoiNTS MAXIt-M-1 15 ' I!AGoH Y'!AY', UNU!SS NOTED OTHERI'IISI! ( 512! TY'PI(;AJ.. DeTA IL.& ). 4 . PI'WVIDE FI'I.I:I:·DAAININ6 6AAVI:LS AND c;oMPACT'!:O FIL.L. I ~'+ERE: Nf:(;I!SSAAY' ) ~IN6 TO SOILS I!N61NI:I!R'S RE:c;oMMI:NI:'ATIONS. _P_L_A_N_V_I_E_V"' ___________ ~01--~. ·· In = j•-ou \.::::_) o' ---~ .. -=-1'--0-.. --------------------------------~~ 5. c;oMPACTIVI: Ef'f'ORT f'OR <!OAAVI:L5, STRUCo'TUI'I.AL. FIL.L. AND !:XISTIN6 SU66AADES ~lc;H SUPPORT S.0 .6.'S SHALL ee IN ACGOI'I.DANc;l! ~ITH SO IL.S I!N61NEI!I'I.'S I'I.I!(;OMMI!NI:'ATION5. '•' I KURTZ $ ASSOCIATES, INC.. 012 COUNTY RD. 154 LENV'lOOD SPRINGS, LORADO ( 10) <145-6905 GARAGE FOR C.ONRAD V'IAGNER 029 COUNTY RD. 198 GARFIELD COUNTY, COLORADO DR.AifoiN BY: M.C .E.t<.. CHECKED BY: B.J.t<.. SCALE: AS SHOV'lN PROJECT NO.: 05-11.2 DATE: C.ONSTRUC. TION SET: 10/25/10 SHEET TITLE: GENERAL NOTES 4 FOUNDATION DETAILS SHEET: S= = <{) 4" I :I I \: 'T~ • I 1'-1<~<~'-4" I :I TF= "li'-4" TYP ALL AROUND 20'-0" 20'-0" ] . ' ' I o 20'-0" 20'-0" 60'-0" FOUNDAT ION PLAN 1/4"=1'-0" :2'-eu PLAN NORTH EB I I ' l 20'-0" TYi • 100'-0' 20'-0" TYPo TF"' "li'-4"- FT~ TYP ALL~-­ AROUND 4" !-----'!<) T~ • 100'-0" KURTZ c$ ASSOC-IATES, INC.. 50 I :2 COUNTY RD. 154 6LENII'!OOD 5PRIN65, COLORADO (<110) <145-6905 GARAGE FOR C-ONRAD V'!AGNER 0:29 COUNTY RD. 198 6ARFIELD COUNTY, COLORADO DRAII'IN BY: M .C.E.K. CHECKED BY: B.J.K. 5CALE: A5 5HOV'IN PROJECT NO.: 05-11.:2 DATE: CONSTRUCTION 5ET: 10/:25/10 5HEET TITLE: FOUNDATION PLAN 5HEET: S=2 Y'I .Y'I .F.· SEE l -+--'TY.,...P ICAL DETA IL I '\ ' 1o .Lx-~x-~x -x~ . ~~ ~. ~ rv~ _., . / ' J ,..--._3 ' CLEAR "'=S IIIII ~ (9 )· #4 C.ONT II= (STA56ER SPL ICES) I SUPPORT 6AR: 114 0 4'-0" o.c . 6 11 6 11 1'-0 11 TENSION TIE 0 -----A ,., • ~~-o n :2 '-0" 10 " CENTERL INE ! COLUMNII--+---..-I [', I '·::2 " D~ FROM FT5 114 x F ULL HTlciO " I (6 THUS) v 9 N liS HORIZ CLOSED T IE· _,. e e SPACE AS F OLL O Y'I S : !---'_......-~~~~~~~~~ (:2)-ll9 o e" O .c. o TOP , I': OF P ILASTER ~ . CORNER BAR: 1--ll4 X 90 " X 90" o BOND 6M l e ~· l 'f Y'IALL 1 PLANV I E~ ® ------B I"= 1'-0" [/ / 119 HORIZ CLOSED T IE· SPACE AS FOLLOY'IS : ( V (:2 )-119 ~ 8" O .C. C1 TOP 60ND 6M I OF P ILASTER RE INF I ~V~tl~~~ / • • o--~z ~~t---+ 'i' ~ ~ D~ FROM FT5 114 x FULL HT lfiO"V v:>-,z;~ [/ (4 THUS) :r / • PLAN VIE~ @) -----G I''= lt-ou KURTZ $ ASSOC IATES, lNG. 50 12 COUNTY RD . 154 cSLENV'IOOD SPRINcSS, COLORADO (Gl10) Gl45-6905 GARAGE FOR GONRAD ~AGNER 029 COUNTY RD. 198 cSARF IELD COUNTY, COLORADO DRAV'IN BY: M.C.E.K. CHECKED BY: B.J.K. SCALE : AS SHOV'IN PROJECT NO.: 05-11.2 DATE : CONSTRUe T ION SET: 10/25/10 SHEET T ITLE: DETA ILS SHEET : S=3 .. • 4 REFERENCE NOTES; 1. ALL ANCHOR RODS INCLUDING NUTS AND WASHERS FOR SAME ARE NOT FURNISHED BY CHIEF BUILDINGS. 0-:'-~ e- 0:-~ 2. ANCHOR ROD MATERIAL SHALL CONFORM TO ASTM F1554 HAVING A YIELD OF 36 KSI OR GREATER. _, .. g _, .. ~ ... 3. ROD PROJECTIONS ARE RECOMMENDED MINIMUMS BASED ON THE BASE PLATE BEARING DIRECTLY ON THE CONCRETE PIER. IF THE BASE PLATE IS TO BEAR ON GROUT, THE ROD PROJECTION MUST BE INCREASED ACCORDINGLY . 4. ALL DRAWINGS ARE NOT TO SCALE. 9 l:> "' ~ "' Esp -I: .. ~ 0 I ~ 1m - I H8 Hx•3.5k - I ~ liD - I 5o 0 .., !AI ·---------------- ·~U NC IO R • TEMP004.TIF • 41212007-07 :1 5 20'..0 11 0 ... ' , ~ cp ,\ ' ~ ·~ ; ' 60'-0" BL TO BL - 20'-0'' ' ' ' f--f-0 -0 I ' I ! ' I ~·· tJ I 0 • ANCHOR ROD PLAN FINISHED FI .OOR ELEVATION= 100'-0" BASE OF ALL COLUMNS AT ELEVATION= 100'-0" BASE OF FRAME OPENING JAMBS AT ELEVATION= 100'-0" I I 0 ACCESSORY SCHEDULE MARK QUAN DESCRIPTION A 4 3070 WALKDOOR F.O. B . 4 14'-0" X 14'-0'' OVERHEAD DOOR F.O. EWcp 20'a0" 1·:· I I- ~ b ~ 0 _, .., I ~ - IS]~ I;> l:> -"' I • 8 H -e • Hx•3.5k - I 11!1~ I;> ~ I 0· 5o + .., ~ !AI ~ '· ANCHOR ROD DRAWINGS KDM BUILDERS-I BRAD SANDERS RIFLE, CO RF 40'X60'X17' 20' BAYS 2:12 cHIEF.~ 1--D_RA::._WN.:..:_I--C.:..:.HE:_C_K -+ _ _:O_:_:R:_DE_:_:R.:..:.NO:.:.. --ly BUILDINGS ..,...... f---"'DB=---t----'J=-MT~ C089371 diMIMtJICirlllttduarla.k =~IE 3-3Q...07 3-3()..07 . (4) 3/4" DIA. ANCHOR RODS (NOT BY CHIEF) BASE ANGLE (A-20-B) OR BASE GIRT (BG ) MASTIC (NOT BY CHIEF) . . . ·:· WITHOUT NOTCH b .... DE EW CONTRACTOR IS RESPONSIBLE FOR ANCHORING BASE MEMBER TO CONCRETE. BASE ANGLE (A-20-B) OR BASE GIRT (BG) MASTIC (NOT BY CHIEF) -~· ... . ·. ~ ' . , .. 4" + (2) 3/4" DIA. ANCHOR~ODS (NOT BY CHIEF) _ __;D=-:E=-T-=-=-A-=1=-L -8 .,!IN ..- .t ONE PIECE BASE ANGLE (OPB) MASTIC (NOT BY CHIEF) .... ·-·~ - : .•. ~ .. : _. :-···:··· ·: ... -~-..... · :~< .... ! .. ~ -~ WITHOUT NOTCH · • RAMSET, ANCHOR ROD, OR EXPANSION BOLT (2" FROM EACH END THEN SPACING FROM FASTENER SPACING CHART) (TYP .) WITH NOTCH BASE MEMBER DETAILS 1 . COLUMN FOOTINGS AND PIERS MUST BE DESIGNED WITHSTAND HORIZONTAL AND VERTICAL REACTIONS AS SHOWN ON THE ANCHOR ROD PLAN . CHIEF BUI IS NOT RESPONSIBLE FOR DESIGN OF CONCRET FOUNDATION. CHIEF BUILDINGS RECOMME :rHATT E SERVICES OF A QUALIFIED ENGINEER IS TAl CONTRACTOR I BUILDER TO DESIGN T NDA FOR THE INDICATED REACTIONS . 2 . REACTIONS ARE GIVEN IN KIPS. (1 KIP = 1000 LB~. · MOMENTS, IF ANY, ARE GIVEN IN KIP-FT . 3. ANCHOR ROD DESIGN IS BASED ON SHEAR, TENSI AND COMBINED TENSION AND SHEAR. CHIEF BUILDING NOT RESPONSIBLE FOR ANCHOR ROD SIZE RECOMMENDATIONS WHEN ANCHOR ROD CONFIGURATION PLACES THE RODS IN A BENDING MODE . WHEN THE COLUMN BASE PLATE BEARS ON GROUT, THE CONTRACTOR I BUILDER OR FOUNDATION ENGINEER SHALL INVESTIGATE BENDING IN THE ANCHOR RODS AND PROVIDE A SHEAR KEY FOR THE COLUMN BASE TO THE PIER WHEN THE ANCHOR RODS ARE NOT ADEQUATE IN BENDING ABOUT THE PIER . .,:IN .... (4) 1/2" DIA. AN .CHOR RODS (NOT BY CHIEF) OVERHEAD DOOR WIDTH OVERHEAD DOOR ANCHOR ROD DETAIL • .-IN .... (4) 1/2" DIA. ANCHOR RODS (NOT BY CHIEF) NOM . DOOR WIDTH 3'-0", 4'-0'\ 6'-0" 3'-7" (3068 & 3070) 4'-7" (4070) 6'-7" (6068 & 6070) DETAIL • .-IN .... been designed for a collateral load of 1.5 psf. ~o:ads due to ceiling panels, ducts, sprinkler electrical equipment, conduit, fireproofing , mechanical loads , etc., cannot exceed this load . In no case shall the total unifonn collateral load indivldiUi\11 roof member exceed the product of 1.5 psf the spacing of the supporting member. Nor shall any individual point load or summation of point loads on any one roof member exceed the product of 1.5 psf times the member spacing times half the member length. In addition, no individual point load on a purlin can exceed 65 lbs. All loads suspended from purlins shall have the load Introduced through the web and not the flange of the purlin. Hangers cannot be supported from the edge of flanges or through holes in the flanges of the Design of hangers and their attachments are not by Chief Buildings . Chief Buildings is NOT responsible for lateral or longitudinal bracing of suspended members subjected to horizontal service, seismic, or wind loading. Chief Buildings neither assumes nor accepts any responsibility for the design of hangers, bracing of suspended members, transverse support members, nor connections to roof purlins . It is the responsibility of the Buyer/Contractor and/or End Owner to have this design performed by a registered design professional. HANGER AT INDIVIDUAL ZEE PURLIN PURUN HANGER CONNECTION MUST BE THROUGH THE WEB HANGERANDCONNECTIONTOPURUN -ARE NOT BY CHIEF BUILDINGS I MAXIMUM INDMOUAL t POINTLOAD HANGER BETWEEN ZEE PURLINS STRUTS AND CONNECTIONS r ARE NOT BY CHIEF BUILDINGS 'r;:::>--~--~ '-PURl.IN MAXIMUM REACTION \ \ MAXIMUM REACTION PUR UN ATPURUN ATPURUN HANGER AND CONNECTION TO STRUTS ARE NOT BY BASE ANCHORAGE SPACING FOR STANDARD BASE ANGLE, BASE GIRT OR ONE PIECE BASE WITH CS OR AP WALLS MINIMUM MAXIMUM FASTENER TYPE & DIAMETER EMBEDMENT SPACING 1/4" WEDGE ANCHOR CD 11/4" 3'.zy' 1/4" SCREW TYPE ANCHOR @ 11/2" 3'-0" 3/8" CAST-IN ANCHOR ~ .. -:;~1 ~1'11A~UI\ 3'-0" 1/4" HAMMER·IN @ 1 3/8" "2'-0" 0 .14" POWDER ACTUATED @ 1 1/4" 1'-8'' CD HIL Tl KWIK BOLT®, RAM SET TRUBOL T®, POWERS POWERSTUD®, OR EQUAL @ CFS TAPCON®, HILTI KWIK.CON II®, POWERS WEDGE..fiOLT®, OR EQUAL @ POWERS ZAMAC HAMMER SCREm, HILT! METAL HIT ANCHOR®, OREQUAL . . . @ POWERS BALLISTIC POINT PIN, RAMSET 1500/1600 SERIES, HIL Tl UNIVERSAL NAIL OR EQUAL FASTENER SPACING CHART Building Design Criteria C089371 Building Code 2002 MBMA Occupancy Category Roof Live Load Collateral Load Ground Snow Load (Pg) E>:posure Factor (Ce) Thennal Factor (Ct) Importance Factor (I) Flat Roof Snow Load (PI) Minimum Roof Snow Load Building Enclosure Wind Speed Exposure Category Importance Factor (I) Wind Pressure (q) Seismic Ss 51 Seismic Importance Factor Use Group Design Category Si t e Class Seismic Resisting System Cs SDS SD1 Analysis Procedure Base Shear Other Loads; IBC 2003 St&~ndard Buildings 20 psf (Tributary Area Reduction Not Allowed) 1.5 psf 40 psf 1.0 1 .0 1.0 28 psf 40 psf Enclosed 100 mph (GCpi :1: 0.18) c 1.0 19.68 psf 43.6% 9.0% 1.0 I c D Steel System (R=3.0) 0.141 . 0.422 0.144 ELF 5,8211bs. None NOlWITHSTANDING THE ADJACENT SEAL, NEITHER THE ENGINEER NAMED ANCHOR ROD DRAWINGS REFERENCE NOTES 1. ACTUAL BASE PLATE DIMENSIONS MAY BE SMAL~ER THAN BASE PLATE DIMENSIONS SHOWN . ------ ..;UN CIOR -TEM?OOS.TIF • 41212007 -07:15 ~ NOR CHIEF BUILDINGS IS ACTING 1-4---------------------j AS THE ENGINEER OF RECORD . THE ,A.. 3 ENGINEER NAMED AND CHIEF BUILDINGS ~ -------------------1 RESPONSIBILITY IS LIMITED TO THE 1---------------------j STRUCTURAL PERFORMANCE OF THE A PRE-ENGINEERED COMPONENTS ~ DESIGNED BY CHIEF BUILDINGS . KDM BUILDERS I BRAD SANDERS RIFLE, CO .·• This building has been designed for a collateral load of 1.5 psf. The total applied loads due to ceiling panels, ducts, sprinkler distribution lines, electrical equipment, conduit, fireproofing, other piping and mechanical loads, etc., cannot exceed this collateral load. In no case shall the total uniform collateral load on an individual roof member exceed the product of 1.5 psf times the spacing of the supporting member. Nor shall any individual point load or summation of point loads on any one roof member exceed the product of 1.5 psf times the member spacing times half the member length. In addition, no individual point load on a purlin can exceed 65 lbs. All loads suspended from purlins shall have the load introduced through the web and not the flange of the purlln. Hangers cannot be supported from the edge of flanges or through holes in the flanges of the purllns. Design of hangers and their attachments are not by Chief Buildings. Chief Buildings is NOT responsibl~ for lateral or longitudinal bracing of suspended members subjected to horizontal service, se ismic, or wind loading. Chief Buildings neither assumes nor accepts any responsibility for the design of hangers, bracing of suspended members, transverse support members, nor connections to roof purlins. It is the responsibility of the Buyer/Contractor and/or End OWner to have this design performed by a registered design professional. HANGER AT INDIVIDUAL ZEE PURLIN PURLIN HANGER CONNECTION MUST BE THROUGH THE WEB HANGER AND CONNECTION TO PURLIN -ARE NOT BY CHIEF BUILDINGS I MAXIMUM INDIVIDUAL t POINTLOAD HANGER BETWEEN ZEE PURLINS PURUN STRUTS AND CONNECTIONS r ARE NOT BY CH IEF BUILDINGS ~:>--_:_--1j '\__ PURLIN ~---r---c::f \ MAXIMUM REACTION ATPURUN MAXIMUM REACTION \ AT PURLIN HANGER AND CONNECTION · TO STRUTS ARE NOT BY CHIEF BUILDINGS REFERENCE NOTES I . ALL PURLINS ATTAC H TO FRAMING USING "STD" ATTACHMENT UNLESS NOTED . REFER TO GO MANUAL SECTION 4 FOR BOLT LOCATIONS. 2. "T'' = TOP SAG ANGLE . "B" = BOTT()t,1 SAG AN GLE . ---'-------·--------· . \IU NCIOR • TEMP007.TIF • 4/2/2007 • 07:15 60 ' 0" BL TO BL - 20'-0" 20'..()" PIA (TYP U.N.) 3'·1~" 3'·1i" P2A (TYI' U.N.) u-= 0'-oi" EDGE OF PURLIN REVISIONS ~--------------------~~ A-------------------------1 A -----------------------! .L1A ------------------------1 / " / " / " / / " / " / " / " / 2WB ROOF FRAMING PLAN NOTWITHSTANDING THE ADJACEN T SEAL, NEITHER THE ENGINEER NAMED NOR CHIEF BUILDINGS IS ACTING AS THE ENGINEER OF RECORD. THE ENGINEER NAMED AND CHIEF BUILDINGS RESPONSIBILITY IS LIMITED TO THE STRUCTURAL PERFORMANCE OF THE PRE-ENGINEERED COMPONENTS · DESIGNED BY CHIEF BUILDINGS. 20'..()" 3'·1!" 3'·1j'' PIA (TYP U.N.) 1'-2" 1- 0'-01" 4 ~ EDGE OF PURLIN / / / " --0 y I )G HEG • rlir ~-'>··•·.,~Sr. . ROOF FRAMING DRAWINGS ·?.~··_j ~\;·''-Jt;~;:~ OM BUILDERS I BRAD SANDERS ' , •. ~ .. .J ·;;:,. o\F'-1?----..:._-------------------~--------J ., . . 3~·i 35 • ·-IFLE, CO _ -;1' jj/YI/ 1 . ,·~-~~,'1":,'-~<_.!-F-4-0':....X_60-'X_1_7_' -2-0'_B_A_Y_S_2_:1-2------------1 ~,---t l/'f'jlfJ·r -~~:> · HIEF.~ DRAWN cHEcK oRoERNo. RF1 I , --.<'i • f----f----f---------1 ..,._. -f BUILDINGS DB •dMtionaiCJWfl~dunri•&lnc. ~~o, NE f--="---f-----1 CQ893 71 ''"''"'" 12 -=o:::::-:J-, 2.000 4 '-10 101 101FF102 3'-8 3 '-6 REVISIONS NOTWITHSTANDING THE ADJACENT SEAL. NEITHER THE ENGINEER -.---------------1 NAMED NOR CHIEF BUILDINGS IS A ACTING AS THE ENGINEER OF ~-------------1 RECORD. THE ENGINEER NAMED AND CHIEF BUILDINGS ~ RESPONSIBILITY IS LIMITED ~ TD THE STRUCTURAL PERFORMANCE -.--------------1 OF THE PRE-ENGINEERED ~2 COMPONENTS DESIGNED BY CHIEF ~--------------1 BUILDINGS. ~------------~--~ .. ~ cp cp cp 1" 20'..0" I 20'..()'' I 20'-o" -~ r ~ ~ "" ,// " / I I " / I I " // ' " !::. " '/ ~ ~ "~ / -/; ~ ... ~ / " ll ..... _ ~ / " rZII .., I I // " I I ~ ' • {:!- // "'-, ~'-/ ... !9 3WB .., / -...: ~ ~' ~ IAl IAl SIDEWALL FRAMING EL. COL. LINE: A GIRT P. , ib- cp cp . -~ cp ~ 1" 20'-0" 1· -I 20'~0" ~ r -~ - ~ // / I / I I --~-~~ "...., // // !::. -5> ·' ... ( ,_ /)' ... -~~· / " ~ / " I ~ ~ . I // "-, I ~ I // " ~ 3WB ' v " ~ IAl ~ IAl SIDEWALL FRAM ING ELEVATION COL UNE: C GIRT DEPTH : 8" REVISIONS NOTWITHSTANDING THE ADJACENT SIDEWALL DRAWINGS & SEAL, NEITHER THE ENG INEER NAMED -.'i/Y~ NOR CHIEF BUILDINGS IS ACTING . \)0 REG/ KDM BUILDERS/ BRAD SANDERS AS THE ENGINEER OF RECORD . THE & ENGINEER NAMED AND CHIEF BUILDINGS ~~ ••••••• 8~ RIFLE, CO RESPONSIBILITY IS LIMITED TO THE ~ ~·~·~~'t;>,\.M4y;;·.~ STRUCTURAL PERFORMANCE OF THE ~ c ;~ .z. .a RF 40'X60'X17' 20' BAYS 2:12 .Lt. PRE-ENGINEERED COMPONENTS :·:(~/ 3.1 3¥MZ:: CHIEF.~ DRAWN CHECK ORDER NO. IY. DESIGNED BY CHIEF BUILDINGS. 't•' . -:) 0 • '-il ~ , '·o ' ."tJ BUILDINGS DB C089371 .:;. :-;:._"c. •• ~"" , dWiaMolarltf6tdwlttu.*-~~ tl! ·· •. :...,<. '{'t ..,0 , ~,) c too)~~~\:). ' -~~),,,!H I , , """"" ·~~-::.-.:_:;·~;'1.~1"' --------· ----·------···--- 'II UNC!OR -TEMP008 . TIF -4/2i 2007 -07 :15 ' .· ·.-_; r-l I I I I I I REFERENCE NOTES 1. FOR OPENING TRIMS, REFER TO GENERAL DETAILS . -----·------------------····----------------------·-·-· \IUNCIOR • TEMP009.TIF • 4/'))2007 -07.15 SIDEWALL SHEETING EL COL. LINE: A SIDEWALL SHEETING ELEVATION COL LINE : C REVISIONS r -l I I I I I I r -l I I I I I I cp SIDEWALL DRAWINGS KDM BUILDERS I BRAD SANDERS RIFLE , CO RF 40'X60'X 17' 20' BAYS 2:12 CHIEF.Efl t--D_RA_WN_+--c_He_c_K -+-__ o_R_DE_R_No_._-; ~~~~~~~~~ ~~~~D.NE DB C089371 111102-2071 52 .. ~ '-? 1>1 b ~ ~ .. ~ ~ !9 "' ~UNC!OR • TEMP01 0.TI F • 41212007 • 07'15 : : I I I I I I I I I I I I I I ' 14'-0" 20'-Q ' ---r -- I I I I .I C? C? I s "~ I 0 ---r-- 20'-Q" . -----. - - - --r-- - - ----::-==----...... ---------,-----~'-?~~ --_---u --u ~ --__ ~n ~~:: ~~ :: .Ab1111-~ I I \ : I I I I . Q .~ :: c.'\ C-' I I ; JJ I I I I I I . !9 I I .., I I I I I I .. I 3'-0" I 14'-0" . I 14'-0 " I a·-o· 1 f---1' _1;-· ______,..).---13'-~" .I /; -'j ENDWALL FRAMING ELEVATION .v 1m ENDWALL FRAMING ELEVATION COL. LINE: 1 GIRT DEPTH : 8" ~ REVISIONS NOTWITHSTANDING THE ADJACENT 1---------'-'.c::..--'-...:....:....:__ ______ -1 SEAL, NEITHER THE ENGINEER NAMED 1 ------------------{ NOR CHIEF BUILDINGS IS ACTING J-=~=------------------1 AS THE ENGINEER OF RECORD. THE A. 3 ENGINEER NAMED AND CHIEF BUILDINGS ~ -------------------! RESPONSIBILITY IS LIMITED TO THE F=--------------·-----1 STRUCTURAL PERFORMANCE OF THE /4.. 2 -·---J PRE-ENGINEERED COMPONENTS .tf.64. DESIGNED BY CHIEF BUILDINGS . F==--------------~ ~---------------------~ COL.LINE :4 Gl RT DEPTH: 8" ENDWALL DRAWINGS KDM BUILDERS I BRAD SANDERS RIFLE, CO RF 40'X60'X17' 20' BAYS 2:12 CHIEF.~ f--DRA_WN-+_cH_E_cK-t __ o_R_DE_R_N_o. _ _,.Y,1: 2 BUILDINGS . ..,. DB C0893 1 ,,...,, __ ... =~ ... r----+-----1 7 ,,..,, . I REFERENCE NOTES 1. FOR ,OPENING TRIMS, REFER TO GENERAL DETAILS. I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I ENDWALL SHEETING ELEVATION COL. LINE: 1 -··· . -------· --------··---------------- \IUNCIOR ~ T EMP01 1.TlF • 4/2!2007 • 07:,5 rdtiJ ~~ ~~ . ~ Q 0C:J I I I I I I I I I cp -:::;! ( CHIEF] [.::. I I .• I I I I I I I I I ENDWALL SHEETING ELEVATION COL LINE : 4 (<? « REVISIONS NOlWITHSTANDING THE ADJACENT 1-'-------..:....:.:.:.:...:..c...:.c:...::_.:..c_ ______ --1 SEAL, NEITHER THE ENGINEER NAMED 1 -----------------l NORCHIEFBUILDINGSISACTING \'-1)0 REG!. ~ AS THE ENGINEER OF RECORD . THE I <;::,~ ••••••••• &;, ENGINEER NAMED AND CHIEF BUILDINGS ~ ,.• ~ l-~-M~Y. •. ~ & -----------------1 RESPONSIBILITY.ISLIMITEDTOTHE f C:..":}~. 7«-z·'-~ . -"' (-'-=--------------------1 STRUCTURALPERFORMANCEOFTHE 1; ~ ? ,..?"'!~ 11'//,/ ENDWALL DRAWINGS KDM BUILDERS I BRAD SANDERS RIFLE, CO RF 40'X60'X17' 20' BAYS 2:12 cr :JQ A -------------------PRE-ENGINEEREDCOMPONENTS \\co~ v 813t/7?~' 1 fl.z/t J6\. DESIGNED BY CHIEF BUILDINGS. . <:S)_;~~·.o ,.;_~'/j 07 &. .~.~~~~~~f,~J:'~\~.~:~ CHIEF.~ I--DRA_WN-t_cH_E_cK-+ __ oR_DE_R_N_o._-1~~'2E 2 . ~~~~!!!.! ... ~~ .... r----_:D:.:B:.__-t------1 C089371 11111241171