HomeMy WebLinkAboutInsulation Certificate InfoJim Wilson From: Jim Wilson Sent: To: Monday, November 17, 2014 3:06 PM 'Chad Driggers ' Subject: RE: Insulation Certificate Chad, You should have verification of the material installed and the matching attic chart, loose fill or stabilized? And should list the number of bags used to cover how many SQ. FT. Because of different materials used in certain area's under the blow in and where the depth stick may have started? The depth indicated appeared to be at settled. Thanks Jim Wilson From: Chad Driggers [mailto:cdriggersSS@gmail.com] Sent: Saturday, November 15, 2014 4:29 PM To: Jim Wilson Subject: RE: Insulation Certificate Jim, What was your conclusion based off the info that I sent to you? What do you think about it? thanks Chad Driggers 720 Callicotte Ranch Drive From: Chad Driggers [mailto:cdriggersSS@gmail.com] Sent: Wednesday, November OS, 201410:12 PM To: 'Jim Wilson' Subject: FW: Insulation Certificate Jim, I apologize I was wrong when I said I didn't have this info today. My insulator had sent this to me a few weeks ago, and J assumed at that time it was just for the first phase of insulating and honestly have been so busy that I didn't even look at it until tonight. This covers everything that he has done. I would ask you that if you feel that we have not reached my target level of RGO in the attic area, that you please let me know and I will ask my insulator to come back to inspect his guys work to see what he thinks. Based off this, it appears that I need to have 17.5" of the cellulose. There is also one thing I didn't mention to you while you were up here Jim. That is I had some extra batts and about 8 full 2.5" inch foam panels left over from earlier in the project that I laid down in between the trusses on Monday before it was sprayed. After you left I thought about that and wondered if maybe that was throwing you a bit. The area I used the left over batts and foam where in the SW corner. Basically right when you pop out of the house into the attic, they would have been dead in front of you , some right behind you and then running into the corner as you would look to your left. Most of the batts were 4 inch batts, but somewhere 6 inch. When you were measuring, are you sure you were hitting sheetrock and not my foam panels or the top of a batt? 1 thanks Chad Driggers 720 Callicotte Ranch Drive From: Vandenheuvel, James [mailto:James.Vandenheuvel@installed.net] sent: Monday, October 20, 2014 7:29 AM To: Chad Driggers Subject: Insulation Certificate Chad, I've attached the certificates for the insulation installed on your project. You will need to provide this information for the inspector at the time of the insulation inspection. Let me know if you need anything else. 'Tfiank.s. James 'Yancfenlieuve( COY~,_,NO T'HB WCBTU\H :'9'.0pt_, ~ ... r -.-l-"•• C~L.i.111.<lel Accurate Insulation Cell: 970·260 ·2134 Office: 970·241-8871 Fax:970 ·255 -8906 2 i< f ·a..~· ~·~ ATTIC CARD THIS IS GREENFIBER9 STABILIZED FOR ATIICS ONLY CELLULOSE INSULATION * THE ABOVE COVERAGE CHART IS BASED ON A NOMINAL BAG WEIGHT OF 30 LBS . USING A VOLUMATIC Ill, 3RD GEAR AND s-GATE . THE CHART IS BASED ON SETTLED THICKNESS AND IS FOR ESTIMATING PURPOSES ONLY. DO NOT EXCEED MAXIMUM SQUARE FEET COVERAGE PER BAG . THE APPLICATOR MUST INTALL BOTH THE MINIMUM NUMBER OF BAGS PER 1.000 SQ. FT. AND THE MINIMUM INSTALLED THICKNESS TO INSURE THE STATED A-VALUE HAS BEEN REACHED. FAILURE TO MEET BOTH THESE REQUIREMENTS MAY PREVENTTHEAPPUCATION OF SPECIFIED A·VALUE. THE INSTALLED MOISTURE CONTENT MUST BE BETWEEN 16'Y .. AND 25% IN ATTIC APPLICATIONS. THIS COVERAGE CHART DOES NOT APPLY TO DRY LOOSE· FILLATIICJFLOOR APPLICATIONS . THIS PRODUCT IS NOT INTENDED FOR SPRAY APPLIED OR DAY DENSE-PACK WALL APPLICATIONS. JOB CONDITIONS , APPLICATION TECHNIQUES, EQUIPMENT, AND SETTINGS CAN INFLUENCE ACTUAL COVERAGE. MINIMUM NET WEIGHT IS 28 .5 LBS. ~ S\~ te\\in~~ <1~ i ~-\\i c, f\ius A TIIC INSULATION R-I~ I Insulation has been installed to the R-value Indicated above with GreenFiber Insulation. GreenFiber provides outstanding thermal performance, fire- reslstance and sound control . Consisting of 85% _recycled content , GreenFiber IF1sulation is specially treated for flame resistance. R-value means resistance to heat flow -the higher the R-vaJue, the greater the insulation power.• Residence Address: 12.0 to\\\~ Ro.N.'f\ ~r Installed by: ~uro.~ Tu~\l\o.\\on -Builde11 Company Name: t\o.\jQs ~V\S\roc.\ion - Builder Signature : . Date Installed: ______ _ CERTIFJCATION Attic: GreenFiber Stabilized for Attics Only Insulation, manufactured by GreenFiber. This is to certify that the attic insulation has been installed in ·conformance with the coverage chart recommendations above using_ bags to cover sq. ft. to obtai n an R-value of ___ . Manufacturlno Lota!ions: Albany, NY Charlotte . NC Delpl'los, OH Norfolk, NE Phoenix, AZ FOR MORE INFORMATION CONTACT GREENFIBER: 800.228.0024 greenflber.lnfo@greenfiber.com Corporate Office: 2500 Distribution Street. Suite 200 Charlotte NC 28203 • . Sall Lalca City, UT Tampa, Fl Waco, TIC (p) 600226.0024 (I) 704.379.06S5 www.greenfiber.com PM-6.3-12 Rev G 02110 TM-6.4-11RevB08/09 f ·'-'~; ~.~, .... 'P'"' ._ ._ r r ~~ ATIICCARD THIS IS GREENFIBER\ID LOOSE FILL CELLULOSE INSULATION R·Valueat 75• FMean Temp. Va!o1de resislenaa lenr.la (valol R) a 7Sfde lemperatUl'il media 11 13 19 22 26 30 32 38 40 44 48 49 50 60 Net Coverage Minimum Thickness (inches) (no adjustment lor lraming) Elqiesor minimo (tnpu~llasl Cobenura ne!J (s:n compensati6n para d tn:ramlllol lniltal lnstaned Thid<ness Espesor inical inswa:lo 3.40 4.01 5.84 6.74 7.94 9.13 9.72 1149 12.08 13.25 14.42 14.71 15.00 1790 Sellled I Maximum Thiclmess Sq. fl per Bag EsPt$0f ~ros ilSt~QdO Cua:IB:lo 3.06 3.61 5.25 6.07 7.15 8.22 8.75 10.34 10.87 11.93 12.98 13.24 13.50 16.11 mhimos por bolsa 796 66.7 44.2 37.6 31.1 26 .5 24 .6 20.1 18.9 16.9 15.2 14 .9 14.5 11.6 Mimimum Bags per 1,000$q. fl. C1n11dad minma de bolsas por 1,000 pies cuadradM 12.5 15.0 22.6 26.6 32.1 37.8 40 .7 49.7 52.8 59 .1 65.7 67.3 69 .0 86.4 M:nimum WeirJht per Sq.fl. Pesom;n;mo po< pie e11adrado 0.376 0.450 0.679 0.799 0.963 1.133 1.221 1.491 1.584 1.774 1.970 2.020 2.070 2.593 Gross COYl!rage (based on 2"x 6" framing on 16" centers) Rtcubrimeinto Sr~to (9mao en armu6n de 5.1 cm {21 x 15.2 cm (61 en cenlro de ~G.64c:tn (161 Maximum Sq. fl per Bag Mtlros Cuae1aao m!xlmos pol bolsa 88 .0 73.6 46.5 40.7 33.3 28.1 26 .0 21 .1 19 .8 17 .6 15 .8 15 4 15.0 11.9 Mum mum Bags per t,OOOSq. Fl. Cin1idad mio.ma de !>Olsas per 1,000 pies cuadraaos l1 4 13.6 20.6 24 .6 300 35 .6 38.5 47.5 50.5 56 .8 633 650 66 .6 83 .9 TllE ABOVE COVERAGE CHART IS BASEO ON A NOMINAl BAG WEIGHT OF 30 LBS USING A VOLUMATIC Ill, 3rd GEAR ANO 8' GATE. TllE CHART IS BASED ON SETTUO THICKNESS AND IS FOR ESTIMATING PURPOSES ONLY. DO NOT EXCEED MAXIMUM SQUARE FEET COVERAGE PER BAG. THE APPLICATOR MUST INSTALL BOTii THE MINIMUM NUMBER OF BAGS PER 1000 sa. FT. AND THE MINIMUM INSTALLED THICKNESS TO INSURE THE STATED R·VAlUE HAS BEEN REACHED. FAllURE TO MEET BOTH TllESE REQUIREMENTS MAY PREVENT THE APPLICATION OF SPECIFIED R·VALUE. THIS PRODUCT IS INTENDED FOR ORY APPLICATION ONlY JOB CONDITIONS, APPLICATION TECHNIOUES, EQUIPMENT, ANO SETIING CAN INFLUENCE ACTUAl COVERAGE. 00 NOT ADO WATER TO THIS PRODUCT. MINIMUM NET WEIGHT IS 28.5 LBS. Thermal Resistance (R value) Re$1S1tnw t!nna lRJ 13 21 Fram ing £slJ1Jcluri z~• i.i:G Installed Th ttkness (inches) Espesor tl'l$!ali~o (ptAgms) 3.5 5.5 M1mmumWt. Per Square Foot lll/lt2 P.so mfr•mo ~or pe cuittrado 1~t 1.02 1.60 Maximum Coverage Per Bag (Adiusted for Fram1ncl 112/Bag Cooerlura rrh!1111 POt balsa (txr1c:onwuiln !*l eleotram1~o)ft~ (16"oc) I (24"oc) 32 .4 I JL3 20.6 19.9 THIS COVERAGE CHART IS FOR ORY APPLICATIONS ONLY ANO IS BASED ON THE KRENOL KS200, WITH MATERIAL APPUEO Of\Y. FOR MAXIMUM COVERAGE PER BAG (ADJUSTED FOf\ FRAM ING), THE FRAMING FACTOR FOR 16" OC STUD SPAC IHG IS 9.375o/a; FOR 24' OC STUD SPACING THE FRAMING FACTOR IS 6.25%. GreenF1ber provides outstanding thermal performance , fire-resistance and sound control. Consisting of 85% recycled content, GreenFiber Insulation 1s specially treated for flame resistance . R-value means res istance to heat flow -the higher the R-value, the greater the insulation power. CERTIFICATION: This insulation has been installed in conformance with the above recommendations, to provide a value of R-using bags of this insulation to cover square feet of area. Builder's Signature:-------------------Company Name: ___________________ ~ Date: ____ _ Applicator's Signature:------------------Company Name: ___________________ ~ Date·------ FOR MORE INFORMATION CONTACT GREENFIBER: 800.228.0024 greenfiber.info@greenfiber.com GreenFiber Corporate Office 2500 Distribution Street, Suite 200 Charlotte NC 28203 www.greenfiber.com MANUFACTURING LOCATIONS: Albany, NY Delphos, OH Norfolk, NE Phoenix, AZ ~ ~~ • MADEINTHE USA Salt Lake City, UT Tampa, FL fliSCScertified .. Waco, TX W'C'ICUM IS111i ltlCYa.fD rotmUT U~'<JSlCCIHWW:R lO' ,..._<otcSIJWI PM·6.3-24 Rev F 01/13 -. "'. ·~ .' ...... ' . <.. • ,· : ,• .• -~.. • ::•, ,•'i ·~!:·._;~···: ' -• .;..I ·•"'1"'1'l1.,."!' .,I • • • • '. ..,..,.,,._ !• \, .::··· ~·~ ~r-:·:::fl~.~ . ·-l ~--.·~~:-·)'. :, t~:· ': = Certificate of Insulation il~lf ::;;;:,..;~r.~~:.~·j:_..: .\ ... t ;~ •• ~1. ~ .. ti~i:t,-,.i,:r.+4 ~·r i ,•I .,,.r,;-~!. '· £::;·-;r~~·:r::·[.t~,· .... ~ f: .::::.: The undersigned certifies that Knauf Insulation.products have been i nstalled in accordance with the manufacturer's, recommended applications for these -products. Sloped Ceilings Attic Areas f'\\d Floors Above Grade ~l..~i\b Walls Basement/ Crawlspaces ~~t'Q.~CV Kraft Unlaced Fa~ 0 0 D D ~ D ' D ~ D Foil Faced D D D D D FSK B'oVfing No. of Co,Yer~g~ Foil Insulation R·Value Thickness Packages Area (SF) D D JJ/I\ __ in. _sq.ft. D D ~A. __ in. _sqJI. D D \<\ 'Ii Min. __ sq .ft . 0 D \q <o''~ . __ in. __ sq.ft. D D 30 r() in. _sq .ft . 1'2.() to.\\ \c.dre, Ro.t\__<l\_\)f _ _ Lot _'2.\ tn\\ \c.ote. Runch Dr Street Address on\ . - -. -. ---.. ----:-Lot~No. -Subdivision tnr \))f\ ~ ~ \.~ ~\Cs>~ City ~-"'· L ,-.... \ ~ 'Sta~ Zip ru.~f0.1e,, .lJ\~~\0.\\1 lnstallina:c. Date Keep this certificate with olher valuable homeowner papers. When lhis property is sold, .rhis certificate should be p assed on lo the purchaser of lhe properly. . ~ ~ . . . . . ·. '· !:~~f~~.~~.._ t 1 ~: .• ~-r.~~-==-·r: .:..~.-1 !'ij'(9i :.~. r~~ ... ~~p~;; !~t:.!~.,..j.t•"'! ~t ... t-t r#!' • ~l-1"'-=-'·. '· ~··· .. f· ·;;;: ~~~ .. J •. ofl!Jt.~;~l':;l ..... .., •. ,..~ti\._.-;,.. . ~. :.t • .; •. .:t ... e--..::tt . ··' • --$! •-!~'-=--~ •.• D•·BASF The Chei:nlcal CQmpany Spraytite 158 Oosed-Cell Medium Density Spray Polyurethane Foam PRODUCT DESCRIPTION: SPRA YTITB 158 ls a closed-cell polyurethane system utilizing an EPA approved, zero ozone-depicting, blowing agent. It is designed for use in commercial and residential constructlon applications. SPRA YTlTB I 58 is compatible with most common construction materials, but can only be processed with BASF I!lastospray 8000A Isocyanate. Benefits of SPRA mTE 158 include: • Superlor insulation performance • Control moisture infiltration • Controls air infiltration • Ease ofepplication • Non-fibrous • Structural properties Al'l'ROV ALS AND CREDENTIALS: ASTM E-84•/•• Listed at SGS US Testing Co .. Inc. Cllw I (SPF Thickness 4.0 inches) NFPA 286 lGcncral Use) 8 inch wall ICC ESR-2642 Flame Spread Index 25 or less Smoke Development Index 450 or less 12 inch cathedral ceilings with 15 min. thermal barrier • -This llUlllOlical rl1111• sprue! roting d-not tdlccillarards pitlDlllCd by Ibis or ony ochar cnaterielundet ••Nil rwo candillon1.1'olylll1!.lh•11& foam 1yolems should not flo lo& exposed (unless ollallltd per CGdo) md 01ust bo PfOtec:llli by a minim•m J 5-mnnllo h:rinal barrier ,.. olhcr code-co~fiant 11111ariel (fadUion ba1tio11 « olhcr •l'P'G.....i U1anblia) u lllowod by applioobla buildi"I oodc(a) 1nd Codt OfToolals. ••ASlM £..14 ioa tcsl cluitPltd (ot Mmplc lhiclcnaa 1pl1 ~ inchc.s. NfPA 216 .,id n>di(oed NPPA(App X) 111 building code/ICC ,....,..,ized1flem1tl,.. iests •wara co..ductcd r,.. .,...,., 11Kow1119Piicadoas ot.sproy (oHL Thon l.., tat nporte un lb<n •ouaed by d:eip prurcuiooafs for lhoit prodlltlHltttloft prooen r,.. projoou. T\'F(CAL PROPER11F.S**: PROPERTY OF CURED FOAM Density (pcf@2" lift) Compl"CS3ivc Strength (psi) Tensile Strength (psi) Closed Cell Content(%) Aged k-factor (Btu in/tu hr 0 P) In conformance with ICC AC377 Permeability (perm inch) Pcrmeancc: (perms) Air Permeancc Djmcnsjonal Stability £%Linear Change) Humid Ase 28 Days ( 158°F at 97%RH) YALJ.IB 2.0-2.3 22 28 >90 0.152 (R-valuc=6.6/in)••• @ 1" 0.147 (R-valuc =6.8/in)u• @ 4" 2.38 2.38@ l"SPP 1.19@2"SPF 0.95 @ 2.5" SPF 0.79@3"SPF 0.050 Us/m2@ 7SPa at I" 2.07% TEST MBTI!OD ASTMD 1622 ASTMD 1621 ASTM D 1623 Type C ASTMD6226 ASTMCS18 ASTMC518 ASTMB96 ASTME2178-0l ASTMD2126 •• -Those plirslcal propmy ~b:s .,. typlc:ll (IW thit malclial Id: Ojlplicd IC Olft d&vclopment facility under conllol~ awlltiofts. SPP pafona111co aadaclual physical propalies will wry with ditfc...,.cs iuJll'llcelion (I.e. lftlhicnl <0ndidon1, pacas c.q11lpmcnl w stllingt, 11111etiel llvouahpa~ cl•). Aa a malt, Ihm: P11bllshcd pr11pc1riu should ba -5 u auidclincs solely fat lh• pu1po1c or CVllluation. Physical propony spccif!Celi<lllt wuld be ddumincd (rcllll aoidll produc:tion tn1luial. BASF CorporaUon f 3630 W1tetfolftr Circle Mll'lllupaUs, MN 55441 Tet 800.7011.(1712 www.911f.ba1r.com ~ Polyurethane ~Solutions D•BASF The ChemlcaJ Company · Installed R-value I U-factor Chart All SPF Cavltv Ontlons -158 Series Frame Wall CC SPF (Inch) Total R-value••• U-facto,. .. • Slzlna twoodl Anv 1· 6.6 a.152 Anv 1.5" 9.9 a.1a1 Anv 2· 13 a.on 2x4 2.s· 16.3 0.061 2x4 3• 20 0.050 2x6 2· 13 a.on 2x6 2.s· 16.3 a .061 2x6 3• 20.1 0.050 2x6 3.5" 24 0.042 2x8 4• 27 0.037 2x8 4.5" 30.4 0.033 2x8 5• 34 0.029 2XB s.s· 37.4 0.027 2x8 6" 41 0.024 2x8 7• ..CB 0.021 2x10 a· 54 0.019 2x10 9• 60.0 0.016 2x12 10· 68 0.015 2x12 11· 75 0.013 .. 'The d1l1 ch111 •"-tho R..,.... of ti• lnsuliltlon. 'R' m11n1 ,.lltlo!IC.I lo h11tn.w. Tht hlgll1r Ille R..,.b1, Ille Gllaltr tllll li\IUollog .-r. ~..., hldelbn R-Y1b11 before you nuv. Tllanl 1111 otllor l••lota lo con&ldor. Th• -oflnoulollon ...... ,.1111 upon ... cl mole, N lyp• ... •Im DI ~·r hClllU, Ind~· Jvel ••• palllms """lcnlt aim , ti YD<' i.,,, 1oa ,...ch houlollon •,..I co•l 1'11" "'"'" lhln llNl ll"U\Mll sovo 111 luel. Ta ••h-p-A.vus, 111 11Hn1lll lhat lhll lftWllh:I bo hallllod pn>!Mrlf. '"IUllClorlo 1ia hwr>• ol A .......... n~lrl BTU /Ill 'F II'). Th•_,.,. n-or, 111• r.t1erll1 P"'*',,_ce Dflha malarLttor •-If. Ualog O.llc1Dtnqulrw1 8PF II .. ed...,,., ... O_ A .. ltftblv. If uHd h Otalloru•amblt h. Aa!•d OHIO ., .... adl .... 8"F 11'1111 ba -pptdMIUlld•I .... hG ............ nlnuty. GENERAL INFORMATION: SPRA YTITB I SB is 11 spray polyurethane foam (SPF) sys~ intended for instnllation by qualified c:onlfllctors trained in the proCC3sing and application of SPF systems, es well as the pl11rnl-cumponcut polyurctbmic dispensing equipment required to do so. Contmctors and applicators must comply with 1111 applicable Md 11ppropriatc storage, h1111dling. processing and safety guidelines. BASP Corpomtion tcclmical sezvicc personnel sho11ld be consulted in nil cases where application conditions nrc questionable. CAUfiONS AND RECOMMENDATIONS: SPRA YTITE ISB is de.signed for nn llflplicalion·ratc ofl4 lnch minimum to 2 inches m1L1Cimum per pass. Once the installed material hll!I cooled it Is possible to lldd additional applications In order to increiwe the overall installed thickness ofSl'P. Sl'RA YTITfi lSR is NOT designed for use os nn IDITERJOR roofing system. BASP Corpomtio11 offcr1 a separate line of products for c.xtcrior roofing applications. For mocc infunnation ple11Sc conlllet your sales rcprcscnltllivc. Cold-storage structu11:.1 1uc11 as coolers and frc:CZCIS demand special design considerations with regard to themial insulation and moisture-vapor drive. SPRA YTITE lS8 should NO'r be installed in these types of constructions unless the structure wm designed by a design professional for specific use as cold storage. · SPRA YTITB JSR is designed for iruitallntion in most stnndnrd construction configurations using common mntcrillls such as wood Md wood products, n1etal tllld concrc:lc:. For other substrates. plc11Sc consult your DASF sales or technical SCIVicc representative for specific rc:comniendations. UMITRD \V ARRANTY INFORMATION -l'LllASE READ CAREFULLY: The inrornia1ion herein Is 10 nsshl custumm in dctcnnining whether our pioducts an: sulcnblc for lheir a?ficntiom. Our products are ouJy inte11ded !Or sale to industrial and co111mc1c:lll c1111Dme11. Custum=r mumcs Ml ~nsibilily for quality conlrol, tcshng a11d delciminaliOR or suiiabllll)' or prod111:1S ror i!J inlcndc.l 911plica1lon or UK. We warrant lhal our products will meet ourwritlcn liqufd componenl spcclric:alions. We mate nn oilier 1w1T11nly of ~ny J;ind, eillicr express or implied, by lllc:t or law, fru:twling any warranty of 1nc1C11111111biliry or Illness for n panicular pwposo. Olir Iota! liability and C11tlllnicrs' cxc:hisivc remedy for all pro'l'l:n claims is n:ptaceruc:nt of n()Jl(.()nformlnc prod11e1 and In no cMnt shaU we lie liable fbr any other d~n111i;cs. BASF Corporation 13630 WalartowerClrcll Mlmeapol!a, UN 554~ 1 Tai: 800.708-0712 www.apt.busf.com ~ Polyurethane ~Solutions --------------·----·- ~-a -------- The coverage chart Is based on settled thickness and is for estimating purposes only. Do not exceed maximum sq. ft. coverage per bag. Actual coverage will be influenced by job conditions and application techniques:rand may vary as much as 1 0% without significantly affecting the stated R-value. Failure of the Installer to provide at least the required number of bags per 1000 sq. ft. and at least the mini- mum thickness may result in a lower installed R-value. This product is Intended for spray-applied application. This coverage chart does not apply to dry application. To obtain optimum performance from this product, we~ recommend maintalnl.ng applied moisture co~tent within the ranges of 25·35% for wall applications and 1 B-22% for attic floors. R-value at I Mlnlinum Thiduless I Maximum N!t Covm&e 7S'F M!an Temp . Jinche.s) (No Adlu5tment !of framinl) To Obtlin ~ 'lhellnal I Installed Insulation ! Thickness I Mulmum Square I Minimum Bars per Resistance(R) of: . S:':': .::,O,~, I Altes Settlin1 feet per Bag • l,000 Square feet :u I J:a-100:7 3.6 I 3.5 _ J 80.2 I G I 5:3 I H I 48J I •V·• I ~·~·· I u . . 45:2 5.9 I 5.7 t 42.4 .1 I s.9 r--J-93 Sidewalls I Framin1 This .!lttk has been insulated to: R-OJ/f[l ~I ~-!~. • I t~$"• , ~ The walls have been insulated to: The floors have been insulated to: R-1 l"3 I P~s 2-11 ~ R-1 N(t\ I Fooff\ Insulation has been installed to the R-valuc indicated above, with Cocoon, the high-effi- ciency insulation. Made from a minimum of 80% recycled materials, Cocoon is scientifically formulated to deliver greater efficiency per inch tbnn other insulation materials. R-Valuc is a measure of resistance to heat flow-the higher the R-value, the greater the insulation power. If you would like to add more insulation to your home, contact your Cocoon dealer. RcsidcnccAddri:ss: 120 tG.\\ i C.~ \\0.nc.\\ \)( Installed by: Acc_uro.~ ~ul o:non Builder Company Name: ~O.~ ~QD~trut.-\\Or\ Builder Signature:---------------------- Da~=·~----------~ Cocoon2 Ii a reglsTered t7adtmatt< at GreenFiber 0 2006 US Grffnflber LLC. All rights l9SeMld. Printed in USA. PM-6.3-56 Rw.B CERTIFICATION A11ka Cocoon2, manufactured by Gr~ber. This is to certify that the attic insulation has been installed in conformance with the coverage chart recommendations above using bags to cover sq. ft. to obtain an R-value of ____ _ lYAU!.i Cocoon2 Stabilized Borate Formula, manufactured by GrecnFiber. This is to certify that the wall insulation has been installed in confonnancc with the manufacturer's recommcndatioJll! to obtain the R~vnluc of .J}_. W:atls and Floon: Type of insulation Manufacturer-----· This is to certify that the wall and floor insulations have been installed in conformance with the manufacturer's recommendations to obtain the R-Values noted above. Installer Company Name: ____________________ _ Installer Authorized Signature:------------------- Dare:. ___________ ~ Manufactwed in: • AJbany, NY • Delphos, OH •Atlanta, GA • E. St Louis, IL • Charlotte, NC • Elkwood, VA • Denver, CO •Norfolk, NE • Phoenix., AZ • Sacramento, CA • Salt Lake City, UT •Tampa.FL •Waco, TX ~~t Charlotte, NC 28203 ph. 800-228-0024 www.grecnfibec.com