Loading...
HomeMy WebLinkAboutCorrespondenceMonte Baker From: Mike Thele <thelepe@wildblue.net> Sent Monday, November 17, 2014 2:18 PM To: Mark Elice Cc: Monte Baker Subject Re: Diamond Ranch Monte, Regarding holes thru the W 10x26 floor beam web for dryer vent and gas piping. A max 4 1/2" diameter hole may be placed with the edge of the hole at least 18" from the connection boltline and a 2" diameter hole may be placed with at least 9" clear between it and the 4 1/2" hole. The holes should be placed at mid -height of the beam web and drilled if possible. Let me know if you need anything else. Thanks, Mike On Mon, Nov 10, 2014 at 11:32 AM, Mark Elice <me'a•iwbinc.com> wrote: Mike, Thanks for the tune up in that area. Please copy Monte with your correspondence. Mark Elice Project Manager ty JackWilkie Builder Est 1974 Office (970) 927-4226 Fax (970) 927-4712 Cell (970) 379-3214 me@lwbinc.com www.iackwiIkiebuilder.com 1