Loading...
HomeMy WebLinkAboutApplication - PermitGarfield County I Building & Sanitation Department 108 8th Street, Suite #401 Glenwood Springs, Co. 81601 Office 945-8212 Inspection Line 384-5003 Job Address: 0244 Red Bluff Vista, GWS Locality: Ironbridge PUD Ph2 Flg1,2,3, Lot 204/2395-122-27-204 ------------~--------~~~------------------------- Use of Building: s/f on foundation w/att garage & cov patio Owner: Allen & Karla & Cheryl Contractor: Hansen Const -------------------------------------------------- Amount of Permit: RAFT total $2,341.93 $750.00 $3,091.93 Date: clerk: ____,{)............,. ]Q=-+, y __ J eX' ____ ?lo.r )~!d:- 1 C).Da-A -L GARFIELD COUNTY BUI LD I NG PERMIT APPL I CATION 108 8 .. Street, Suite 40 1, Glenwood Springs, CO 816 01 Phone: 9 70 -94S-8 2 12 I Fax: 9 7 0 -384-347 0 I In ape ctlon Line: 970-384·5003 Permit No: -+{~B-'~·~.:::3~-- 2 3 4 5 6 7 8 9 10 11 12 NOTICE CJ New (J Single Double D A SEPARATE ELECTRICAL PERMIT IS REQUIRED AND MUST BE I SSUED BY TilE STAT E OF COLORADO. THI S PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORI ZED IS NOT COMMENCED WITHLN 180 DAYS, OR, IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. I HEREBY CERTIFY THAT I HAVE READ AND EXAMI NED THIS APPUCATION AND KNOW 1llE SAME TO BE TRUE AND CORRECT. ALL PROVISI ONS OF LAWS GOVERNING THI S TYPE OF WORK WILL BE COMPLE;'TED WITHIN WHE1llER SPECIFI ED HEREIN OR NOT. THE GRANTING OF' A PERMIT DOES NOT PRESUME TO GI VE AUTHORITY TO VIOLATE OR CANCEL THE PROVISI ONS OF' ANY HER STATE OR LOCAL L AW REGULATING CONSTRUCTIO PERFORMANCE OFCONSTR.~~~.,~ 0 Alteration Addition 0 Move On-Site Sewage Disposal Carport: D Site Plan Total Fee: .) 3LI \ (0 ')s-o oo AGREEMENT Permit Fee: Dated Permit I ssued: PERM ISSION IS HERBBY GHANTED TO THE APPLICANT AS OWNER, CONTRACTOR AND/OR THE AGBNT OF THE CONTRACTOR OR OWNER TO CONSTRUCT THE STRUCTURE AS DETAILED O N PLANS AND SPECI FI CATIONS SUBMJTTED TO AND REVIEWED BY THE BUILDI NG DEPARTMENT. IN CONSIDERATION OF THE: I SSSUANCE OF THI S PERMIT, THE SI GNER. HERBBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND USE REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN LN 30.28.20 I CRS AS AMENDED. 1llE SIGNER FURTHER AGREES 1llATIF 1llE ABOVE SAID ORDI NANCES ARE NOT FULLY COMPILED WITH IN THE LCOATION, ERECTION, CONSTRUCTION, AND USE OF THE ABO¥& DESCR IBED STRUCTURE, THE PERMIT MAY BE REVOKED BY NOTICE PROM 1llE COUNTY AND THAT THEN AND 1llERE IT SHALL BECOME NULl. AND VOI D. THE I SSUANCE OF A PERMT BASED UPON PLANS, SPECI FICATIONS AND OTHER DATA SHALl. NOT PREVENT THE BUI LDING OFFICIAL FROM THEREAFTER REQUIRI NG 11iE CORRECTI ON OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR FROM PREVIENTING BUILDING OPERATION BEING CARRI ED ON THEREUNDER WHEN IN VIOLATION OF THS CODE OR ANY OTHER ORDINANCE OR REGULATION OF THI S JURI SDICTION. 11iE REVIEW OF SUBMITTED PL ANS AND SPECI FICATI ONS AND INSPECTI ONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN ACCEPTANCE OF' ANY RESPONSI B I LI11ES OR LIABLI11ES BY GARFIELD COUNTY FOR ERRORS, OMISSI ONS OR DISCREPENCIES. THE RESPONSI BILITY FOR THESE I TEMS AND I MPLEMENTATION DURING CONSTRUCTION RESTS SPECI FI CIALLY WI TH THE ARTICTECT , DESIGNER, BUI LDER, AND OWNER. COMMENTS ARE INTENDED TO BE CO NSERVATIVE AND I N SUPPORT OF THE OWNERS LNTEREST. I HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE. AGREEMENT ABO¥& (IN ITI AL): __ ~_,tj:J"--7""-- ~t:\tl Fee &dq-P % -l()-0~ g-:5~~ c.~ttcA~ c~ \tl15 lBl-~o -:1$ v . .nq.35 The following items are required by Garfield County for a final inspection: 1. A final Electrical Inspection from the Colorado State Electrical Inspector; 2. Permanent address assigned by Garfield County Building Department posted where readily visible from access road ; 3. A finished roof, a lockable house, complete exterior siding, exterior doors and windows installed, a complete kitchen with cabinets, a sink with hot & cold running water, non-absorbent kitchen floor coverings, counter tops and finished walls, ready for stove and refrigerator, all necessary plumbing; 4. All bathrooms must be complete, with washbowl, tub or shower, toilet stool , hot and cold running water, non-absorbent floors and walls finished and a privacy door; 5. All steps outside or inside over three (3) steps must have handrails, guard rails on balconies or decks over 30" high constructed to all IBC and IRC requirements; 6. Outside grading done to where water will detour away from the building; 7. Exceptions to the outside steps, decks and grading may be made upon the demonstration of extenuating circumstances, i.e. weather, but a Certificate of Occupancy will not be issued until all the required items are completed and a final inspection made; 8. A final inspection sign off by the Garfield County Road & Bridge Department for driveway installation, where applicable; as well as any final sign off by the Fire District, and/or State Agencies where applicable . 9. If you will be connecting to a public water and /or sewer system, proof of the tap fees have been paid and the connections inspected by the service provider prior to issuance of a C.O . A CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL ALL TilE ABOVE ITEMS HAVE BEEN COMPLETED. ****A CERTlFICATE OF OCCUPANCY MAY TAKE UP TO 5 BUSINESS DAYS TO BE PROCESSED AND ISSUED. ****CANNOT OCCUPY OR USE DWELLING UNTIL A CERTIFICATE OF OCCUPANCY (C.O.) IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. I understand and agree to abide by the above conditions for occupancy, useA\QdJhe issuance of a Certificate of Occupancy for the dwelling under building permit# / Vl,ooZ~ tf?-r0--07 Date /2f:JZ r~tf VALVA TION/FEE DETERMINATION Applicant AJJ er-..... Address 6744 Q_.,.J l?lu.% IASM Date ?i:a,3-o1 Finished (Livable Areal: 'L1.r Main h-.,~ 7 Upper JO(p Lower Other Subdivision ~~j3~C..i:". LoUBiock 2otj Contractor l+-ft11S...q '2/,A ... ~ 14~ = Total Square Feet "<,; r Valuation Basement: Unfinished Conversion of Unfinished to Finished Plan Check Fee for Conversion Valuation Garage: Valuation ~?2 1/ S Crawl Space: Valuation Decks/Patios: Covered Valuation Open Valuation Total Valuation GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS For SINGLE FAMILY DWELLING CONSTRUCTION Including NEW CONSTRUCTION ADDITIONS ALTERATIONS And MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. When reviewing a plan and it 's discovered that required information has not been provided by the applicant, this will result in the delay of the permit iss uance and in proceeding with building construction. The owner or contractor shall be required to provide this information before the plan review can proceed. Other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. Any project with more than ten (10) occupants requires the plans to be sealed by a Colorado Registered Design Professional. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following checklist prior to and during design. Applicants are required to indicate appropriately and to submit the completed checklist at time of application for a permit. Plans to be included for a Building Permit, must be on drafting paper at least 18"x24" and drawn to scale. Plans must include a floor plan , a concrete footing and foundation plan, elevation s all side s with decks, balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line and original grade. A section showing in detail, from the bottom ofthe footing to the top of the roof, including re-bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house-rap, (which is required), siding or any approved building material. Engineered foundations may be required. A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. wind speed, wind exposure B or C, and a 36 inch frost depth. All sheets to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be incompliance with the 2003 IRC. I. Is a site plan included that identifies the location of the proposed structure or addition and distances to the property lines from each corner of the proposed structure(s) prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Properties with slopes of 30% or greater must be shown on the site plan. (NOTE Section: 106.2) Any site plan for the placement of any portion of a structure within 50 ft. of a property line and not within a previously surveyed building envelope on a subdivision final plat shall be prepared by a licensed surveyor and have the surveyor's signature and professional stamp on the drawing. Any structure to be built within a building envelope of a lot shown on a recorded subdivision plat shall include a copy of the building envelope as it is shown on the final plat with the proposed structure located within the envelope. Yes X 2. Does the site plan also include any other buildings on the property, setback easements and utility easements? Please refer to Section 5.05.03 in the Garfield County Zoning Resolution if the property you are applying for a building penni! on is located on a corner lot. Special setbac~o apply. Y es._.6_'-"--- 3. Does the site plan include when applicable the location of the !.S.O.S. (Individual Sewage Disposal System) and the distances to the property lines, wells (on subject property and adjactroperties), streams or water courses? Yes 4. Does the site plan indicate the location and direction of the County or private road accessing the property? 2 Yes '{:. 5. Are you aware that prior to submittal of a building permit application you are required to show proof of a driveway access permit or obtain a statement from the Garfield County Road & Bridge Department stating one is not necessary? You can contact the Road & Bridge Department at 625-8601. Yes ){ 6. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcin9 steel in accordance with the IRC or per stamped engineered design? Yes._~,r.:oX------ 7. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and earth? Yes X · 8. Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces and soffits? Yes ,>( 9. Do the plans include design loads as required by Garfield County for roof snow loads, (a minimum of 40 pounds per square foot up to & including 7,000 feet above sea level), floor loads and wind loads? Yes X I 0. Does the plan include a building section drawing indicating foundation, wall, floor, and roof constructi\))'1? Yes _ __,_/\_,_ __ _ II. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roo[;.afters or joists or trusses? Yes._----'-/( ____ _ 12. Does the building section drawing or other detail include the method of positive connection of all columns and beams? Yes X 13. Does the elevation plan indicate the height of the building or proposed addition from the undisturbed grade to the midpoint between the ridge and eave of a gable or shed roof or the top of a fla~ !Yof? (Building height measurement usually not to exceed 25 feet) Yes. __ --J~""---- 14. Does the plan include any stove orzero clearance fireplace planned for installation including 3 15. 16. 17. 18. 19. 20. 21. 22. 23. make and model and Colorado ase 11 certifications or phase II EPA certification? Yes N o_-1-'--'::--:-----:-----: Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the IRC? V Yes No __ ~~~------- Does the plan include a window schedule or other verification that egress/rescue windows from sleeyg rooms and/or basements comply with the requirements of the IRC? Yes ~ No ____________ _ Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable rooms? Yes X No. ______ _ Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and spec~ safety glazing for these areas? Yes ~ No ____________ _ Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicate<\_oy the plan? Yes ~ No __________ _ Do you understand that if you are building on a parcel of land created by the exemption process or the subdivision process, are building plans in compliance with all plat notes and/or CQ,_v91ants? Yes L_ No. ______ _ Do you understand that if you belong to a Homeowners Association (HOA), it is your responsibility to obtain written permission from the association, if required by that association, prior to submitting an application for a building permit? The building permit application will be accepted without it, but you run the risk of the HOA bringing action to enforce the covenants, which can result in revocation of permit issued. Additionally, your Plan Review fee is not refundable if the plans have been reviewed by the Building Department prior to any action by the HOA that requires either revocation or substanti~I 91odification of the plans. Yes ,& No ___________ _ Will this ~he only residential structure on the parcel? Yes )5_ No Ifno-Explain: ______ _ Have two J,2) complete sets of construction drawings been submitted with the application? Y es_-I,C:_'-------- 4 24. Do you understand that the minimum dimension a home can be on a lot is 20ft. wide and 20ft. long? Yes X: No ___ _ 25. Have you designed or had this plan designed while considering building and other construction code requirements? Yes X No ____ _ 26. Do your plans comply with all zoning rules and regulations in the County related to your properties zone district? Yes X No _____ _ 27. Does the plan accurately indicate what you intend to construct and what will receive a final inspectiqn yy the Garfield County Building Department? Yes ~ No __________ _ 28. Do you understand that approval for design and/or construction changes are required prior to the ap(>lication of these changes? Yes ~ No. _____ _ 29. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application submittal and that you will be required to pay the "Permit Fee" as well as any "Road Impact" or "Septic System" fees required, at the time you pick up your building permit? Yes )'< No _____ _ 30. Are you aware that you must call in for an inspection by 3:30 the business day before the requested inspection in order to receive it the following business day? Inspections will be made from 7:30a.m. to 3:30 p.m. Monday through Friday. Inspections are to be calle~ iJI to 384-5003. Yes ~ No __________ __ 31. Are you aware that requesting inspections on work that is not ready or not accessible will result in a $50.00 re-inspection fee? Yes~ No __________ _ ~ . 32. Are you aware that you are required to call for all inspections required under the IRC including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of the building? Yes ,><: No _____ _ 5 33. Are you aware that the Permit Application must be signed by the Owner or a writt en authority being given for an Agent and that the party responsible for the project mu st comply with thei:RC? Yes _ No 7 ------------- 34. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups , unless you as the homeowner are performing the work? The licen se number of the person performing the work will be required at gme of applicable inspection. Yes 25:::. No 7 --------------- 35. Are you aware, that on the front of the Building Permit Application you will need to fill in the Parcel/Schedule Number for the lot you are applying for this permit on prior to submittal of a building penn it application? Your attention in this is appreciated. Yes )( No _______ _ 7 36. Do you know that the local fire district may require you to submit plans for their review of fire safety issues? Yes ,)( No (please check with the building department about this requirement) 37. Do you understand that if you are planning on doing any excavating or grading to the property prior to issuance of a building permit that you will be required to obtain a grading permit?X Yes __,,~~--- 38. Are you aware that if you will be connecting to a public water and/or sewer system, that the tap fees have to be paid and the connections inspected by the service provider prior to the issuance of a Certificate of Occupancy? Yes )( I I hereby acknowledge that I have read, understand and answered these questions to the best of my ability. ~~ ~c!9-tP-0 7 ~ pate 7 Phone: 32tJ-"399 D (days); (evenings) · ProjectName:TCO!Obri~ M~o_;d,,.L6.~'3 /of Cll'l4- Project Address:O-R G.::J""\\ Cn. floC:>\ c c)..'f{ e.. '<. Vt ~ fct 1 Notes: If you have answered "No" on any of the que stions , you may b-t required to provid e this 6 information at the request of the Building Official prior to beginning the plan review process. Delays in issuing the permit are to be expected. Work may not proceed without the issuance of a permit. I fit is determined by the Building Official that additional information is necessary to review the application and plans to determine minimum compliance with the adopted codes, the application may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review, delay in issuance of the permit or delay in proceeding with construction. Bpminreq November2006 7 PLAN REVIEW CHECKLIST Applicant A\ \,-e.Y\ Buildin g _.0ngineered F oundation V Driveway Permit GK~ ~Surveye d Site Plan V" Septi c Permit and Setbacks ~ ~ Gradeffopography 30% / Attach Resi de ntial Plan Review Li st ~Minimum Appb cation Questi onnaire ___!L_S ubdi vis ion Plat Notes ~Fir e Department Rev iew V \1 aluation Determination/Fees ~d Lin e Plans/S tamps/S ti cker . 4Attach Conditions _l..L_Application Signed _ _! .. ,,~.Plan Revi ewer T o Sign Application dParcel/Schedule No. ~ 40# Snow l oad Lette r-Manf. Hms. V Soils Report GENERAL NOTES: Date _ __!~>!__~ -=-2-=s:...._-_o_'/~_ Planning/Zoning :;;perty Line Setbacks __ 30ft Stream Setbacks ~odPlain ~ding Height · ng Sign-off Impact Fees --~ V ~RC Approval __ Grade/Top ograph y 40 % ~annin g Iss ue s _bbdivision Pl at Notes '1Yk IMPROVEMENT LOCATION CERTIFICATE / / ' / ' / 'v / / / / / / / / / / / / / / ' ' / / / / / < ~ ', .'2>" " I I I I I I I I I I '-'- '- '-'- SCALEI 1" = 20' 0244 RE[\ BLUFF VISTA '-'-'-'-'- > ( A / ' / / / / / / / ' / ' / '- '-'- LOT 204 MODEL 1202 FOUNDATION CONCRETE FORM CERTIFICATE '-'-'-'- '- '-. '-~ '-~· I I / ' / / / /-:, / ~. / ' ' ' \ __) ' \ \ \ NOTE: THIS PROPERTY IS SUBJECT TO RESERVATIONS, RESTRICTIONS. COVENANTS AND EASEMENTS OF RECORD OR IN PLACE. THIS IMPROVEMENT LOCATION CERTIFICATE IS SOLELY BASED ON THE RECORDED PLAT PROPERTY DESCRIPTION LOT 204, ACCORDING TO THE AMENDED AND RESTATED FINAL PLAT OF IRONBRIDGE P.U.D .. PHASE 2, RECORDED AS RECEPTION NO_ 702420, COUNTY OF GARFIELD, STATE OF COLORADO FOUNDATION CONCRETE FORM CERTIFICATE I HEREBY STATE THAT THIS FOUNDATION CONCRETE FORM CERTIFICATE WAS PREPARED BY HIGH COUNTRY ENGINEERING, INC FOR IRONBRIOGE HOMES, THAT IT IS NOT A LAND SURVEY PLAT OR AN IMPROVEMENT SURVEY PLAT. I FURTHER STATE THAT THE PROPOSED IMPROVEMENTS SHOWN HEREON ARE BASED ON THE FIELD LOCATION OF THE EXISTING CONCRETE FORMS. ON THIS DATE. SEPTEMBER 20, 2007, ARE ENTIRELY WITHIN THE BOU•'.IOARIES OF THE PARCEL, AND THAT THERE ARE NO ENCROACHMENTS UPON THE DESCRIBED PREMISES BY IMPROVEMENTS ON ANY ADJOINING PREMISES, EXCEPT AS INDICATED, AND THAT THERE IS NO APPARENT EVIDENCE OR SIGN OF ANY EASEMENT CROSSING OR BURDENING ANY PART OF SAID PARCEL, EXCEPT AS NOTED. DA TE, __ S:::E:::P_T~E:::M~B~E::_R:_.-:2:.::0::_. _-2:_-0:.::0:::7 __ JOB NO. , _ _,_2,-,0:.::6:::1 "06-,c0-,c·:.::2:.::0c_-4 _____ _ " / " / " / NOT: " / "v / / / / / EXHIBIT LOT / / / / / A / " / " / " / " / / / LOT 204 MODEL 1202 204 , ___ _ RED BLUFF VISTA I 1. NORTH AMERICAN GREEN S150 EROSION CONTROL BLANKET (OR EQUIVALENT) IS TO BE PLACED ON All SLOPES GREATER THAN 3:1 2. MAINTAIN POSITIVE DRAINAGE AWAY FROM STRUCTURES IN All DIRECTIONS AT All TIMES. 3. CHANGES TO THE GRADING PLAN AND DRAINAGE SHALL BE VERIFIED THROUGH THE ENGINEER OF RECORD PRIOR TO BEING COMPLETED IN THE FIELD. PROPERTY DESCRIBED AS: LOT 204, ACCORDING TO THE AMENDED & RESTATED FINAL PLAT OF IRONBRIDGE P.U.D. PHASE 1, RECORDED AS RECEPTION NO. 654210, COUNTY OF GARFIELD, STATE OF COLORADO; ALSO KNOWN AS: 0244 RED BLUFF VISTA COUNTRY ENGINEERING, INC. 141NYERNESS DRIVE EAST, STE F·l20, ENGLEWOOD, C080112 PHONE 1303) 925-0544 FAX (303)9250547 1517 BLAKE AVENUE, STE I Of, GLENWOOD SPRINGS, CO 81601 PHONE (970) 945-8676 FAX (970)945-2555 WWW.HCENG,C:OM IRONBRIDGECLUB GLENWOOD SPRINGS, COLORADO IRONBRIDGE PLOT PLAN LOT204 ORAWNBV: SPG CHECKED BY: FWH SCALE: t" =20' PROJEcr No: 2051019.00 DATE: PAGE: 7/30/07 FILE: J:/SDSKPROJ/205/ 1 01 9/DWG/D<HIBrTS/LOTS/LOT 204 FUHRMANN ENGINEERING SERVICES, LLC STRUCTURAL CONSULTANTS October 5, 2007 Ironbridge 410 Iron bridge Drive Glenwood Springs, CO Attn: James Hagerman SubjecS,_ Covered Porch Framing n Plan 1202 lronbridge Community Garfield County, Colorado Dear James: PlATTE RIVER PLAZA BLDG. 1205 S. PLA TIE RIVER OR., STE 200 DENVER, CO 80223 OFFICE (303) 715·9885 FAX (303) 715·9890 Per your request, we have provided the required framing for the Covered Porch at the rear of the house. Refer to the attached drawing for detail. Please call if you have any questions. Sincerely, Fuhrmann Engineering Services, LLC Reviewed by: Nathaniel P. MSP attachment cc: file Q:\LETTERS'Jronbridge Homes\Ironbridge _12_92 _ CovPorchfnn.doc '? ~ ~" "'' '?<.; ~ "' "'""" " '<v ~,._c;_,c; o<:> v 1!-v >~'"'" ~~~ '<. "' ~ ~ ~~-rr----~--~----,---,r---,---,r----rr----rr---~----,--n ~ ,.~ v"" q,O 0ov- -'o~o?~!v'?r~ ---------------------------------------1---------' f= q,O'!§.cft.=-~x10 =====~==== 5 6x10 == ====~== I I I I = I , "'<-----tt------tt-----tt-----1!------tHI 2 x8 R. R. 11-H------fl-----11----tt-----lt----11---J>II : '" [@16" O.C.[ I I I r-_j2x LEDGER with 1(_)1--tt----..... : F= / r l3-16d@15"o.c.[ "" 1 _6; I : ®1 ® {~ ® i Hr;;~~=~~-~~~¥= ~c:~=m==ij=::j!:J#= = === = = === = = ~==n ~ / [;: '---BALLOON FRAME -----( IF)§~~~~~~~2~L~V~L::113~§~'F§~dl [;: WALL w/2x6 HGUS412 _.\. C/ \ ~4 TYP f:; @12"0.C. p:i% v PARTIAL FRAMING LOWER PLAN OPT REAR PORCH lRONBRIDGE OOJ.P ii;:I.VI a IJ'Oit'TING COMMUNITY 410 IRONBRIDGE DR. GLENWOOD SPRINGS, CO. 81601 PHONE: (970) 947·9800 FAX: (303) 379·6811 Fuhrmann Engineering Services, LLC STRUCTURAL CONSULTANTS 1205 South Platte River Drive, Suite 11200 Denver, Colorado 80223 ROOF ELEV A&C BALCONY DETAIL PLAN 1202 REVISIONS Joa No. 55·001-BF DATE OCT. 5, 2007 DESIGN MSP CRAniNG MSP CHECI(ED NPG $/<EET 1 OF 1 FUHI;IMANN ENGINEERING SERVICES, LLC STRUCTURAL CONSULTANTS October 4, 2007 Ironbridge Golf Club & Sporting Community 4 I 0 Iron bridge Drive Glenwood Springs, CO 8!601 ATTN: Mike Woelke RE: Post Tensioned Slab-on-Grade Certification 0244 Red Bluff Vista Lot 204 Ironbridge Community Garfield County, Colorado Dear: Mike PLAITE RIVER PLAZA BLDG. 1205 S. PLAITE RIVER DR., STE 100 DENVER, CO 80223 OFFICE (303) 715-9885 FAX (303) 715-9890 As of October I, 2007 all required construction observations for the Post Tensioned Slab-on-Grade Foundation System at the subject site have been completed by this office. From our observations, we have concluded that this foundation has been constructed in accordance with the approved construction documents and guidelines set forth by the Post Tensioning Institute. All required observations and their subsequent letters by this office for the Post Tensioned Slab-on-Grade Foundation System which includes the Trench Beam and Steel Observation including Ufer Rod, Tendon Placement (pre-pour) Observation, and Tendon Stressing Observation have been approved by this office. We also note that the required insulation has been installed per our structural details and the International Residential Code, 2003 Edition. No further observations are required. Please call if you have any questions. Sincerely, Fuhrmann Engineering Services, LLC HY Matthew S. Peterson, P FUHRMANN ENGINEERING SERVICES, LLC STRUCTURAL CONSULTANTS October 4, 2007 Ironbridge Golf Club & Sporting Community 410 Iron bridge Drive Glenwood Springs, CO 81601 Attn: Mike Woelke RE: Tendon Stressing Observation 0244 Red Bluff Vista Lot204 Iron bridge Subdivision Garfield County, Colorado Dear Mike: PlAITE RIVER PlAZA BLDG. 1205 S. PLATTE RIVER DR., STE 100 DENVER, CO 80223 OFFICE (303) 715·9885 FAX (303) 715-9890 Per your request, we visited the subject site on October I, 2007 to observe the tendon stressing operations for post-tensioned slab-on-grade design. The stressing of the tendons were conducted within acceptable tolerances and appeared to be in general conformance with the construction. At this time, tendon tails may be cut off and the anchor cavities grouted with a high strength, non-shrink grout. This concludes the construction of the post-tensioned foundation system. Please call if you have any questions. Sincerely, Fuhrmann Engineering Services, LLC fo~ MatthewS. Peterson, P.E., PTI #1919 MSP:jma attachments file -·-~-~~~---·-·------~~·-~-----------------~·---~-----------~~~---·--------- FUHRMANN ENGINEERING SERVICES, LLC STRUCTURAL CONSULTANTS September 25, 2007 Ironbridge Golf Club & Sporting Community 410 Ironbridge Drive Glenwood Springs, CO 8160 I Attn: Mike Woelke RE: Tendon Placement (pre-pour) Inspection 0244 Red Bluff Vista Lot204 Ironbridge Subdivision Garfield County, Colorado Dear Mike: PLAnE RIVER PLAZA BLDG. 1205 S. PLAnE RIVER OR., STE 100 DENVER, CO 80223 OFFICE (303) 715·9885 FAX (303) 715-9890 Per your request, we visited the subject site on September 14, 2007 to observe the tendon placement and interior trench beams of the post-tensioned slab-on-grade. The dimensions, geometry, and required options have not been verified at this time. The contractor assumes responsibility for the accuracy of all building dimensions, locations on lot, foundation elevations, and the slab step layout. The installation of the tendons and interior stiffened beams appeared to be in general conformance with the construction plans. We observed the top of grade appeared to be at the correct elevation to maintain the slab thickness per plan. It is the responsibility of the contractor to verify slab thickness and tendon layout remain as observed during concrete placement. No other items were observed at this time. Please call if you have any questions. Sincerely, Fuhrmann Engineering Services, LLC frtr Matthew S. Peterson, P.E., PTI # 1919 MSP:jma attachments file FUHRMANN ENGINEERING SERVICES, LLC STRUCTURAL CONSULTANTS September 25, 2007 Ironbridge Golf Club & Sporting Community 410 Iron bridge Drive Glenwood Springs, CO 81601 Attn: Mike Woelke RE: Trench Beam and Steel Observation including Ufer Rod 0244 Red Bluff Vista Lot 204 Iron bridge Subdivision Garfield County, Colorado Dear Mike: PlATIE RIVER PLAZA BLDG. 1205 S. PlATIE RIVER DR., STE 100 DENVER, CO 80223 OFFICE (303) 715·9885 FAX (303) 715·9890 Per your request, we visited the subject site on September 14,2007 to observe the construction of the trench beams of the post-tensioned slab-on-grade. The dimensions, geometry, and required options have not been verified at this time. The contractor assumes responsibility for the accuracy of all building dimensions, locations on lot, foundation elevations, and the slab step layout. The trench beam depth, width, and required steel placement appeared to be in general conformance with approved construction documents. Also, we observed the required l-inch polystyrene foam (extruded) insulation was placed in the trenches at the exterior of the building footprint per plan and is temporarily to the trench wall. We also observed that an Ufer rod was placed at the time of the wall steel installation. No other items were observed at this time. Please call if you have any questions. Sincerely, Fuhrmann Engineering Services, LLC ~ MatthewS. Peterson, P.E., PTI #1919 MSP:jma Attachments file -·------- FUHRMANN ENGINEERING SERVICES, LLC STRUCTURAL CONSULTANTS October 31, 2007 Ironbridge 410 Ironbridge Drive Glenwood Springs, CO Attn: David Ockers Subject: Covered Porch Foundation Retrofit 0244 Red Bluff Vista Lot 204, Ironbridge Community Garfield County, Colorado Dear David: PLA TIE RIVER PLAZA BLDG. 1205 S. PLATIE RIVER DR., STE 100 DENVER, CO 80223 OFFICE (303) 715·9885 FAX (303) 715·9890 Per our telephone conversation, we understand that the covered porch option was not placed with the foundation. Since the foundation at the above subject site is a Post Tensioned Slab-on-Grade system, we recommend incorporating the optional porch with the existing foundation (Option 1). We understand that the existing tendons for the foundation have not been cut and could be spliced at the porch location. Trench beams should be placed at the perimeter of the optional porch. The trench beams should be 12 inches wide by 4 feet deep with (2) rows of #4 continuous reinforcing steel located at the bottom of the trench beam. The vertical insulation attached to the existing trench beams should be removed adjacent to the added trench beams. Embed and epoxy (I) row of #4 bars, 12 inches long, into the bottom of the existing trench beams and tie to a continuous #4 bar. Embedded bars should be located 6 inches from the bottom of the existing trench beams. Dowels are to be embedded 4" minimum and epoxy with Simpson AT structural epoxy or equivalent. Install vertical insulation at the trench beams per the plan details on Sheet F2.0 for the Optional Covered Porch. The porch slab should be 9 inches thick with 2" of horizontal insulation (XPS Type IV) under the slab. New tendons should be spliced to the existing tendon tails. Install a standard splice chuck at the existing tendon tails. Install a 3 inch diameter PVC sleeve, 12 inches long, around the splice chuck. Install the end of the sleeve at the opposite end of where the stressing equipment will elongate the tendon. Seal off the ends of the PVC to tendons using duct tape prior to pouring concrete. We recommend that the concrete be in place and cured a minimum of I 0 days prior to stressing the new cables. Refer to Figure I and 2 for clarification. If some movement in the porch slab is not a concern, we recommend installing 4 foot foundation walls with footings at the perimeter of the Optional Covered porch (Option 2). The foundation walls should be 8 inches wide and bear on continuous footings which are 20 inches wide by 8 inches deep. Provide (2) rows of #4 continuous reinforcing steel at the top and bottom of the foundation walls. The existing tendons should be cut and patched as required. Provide a 4 inch thick structural concrete slab for the added porch. lnstall4x4-W2.9xW2.9 wire welded fabric at the mid-depth of the slab and provide 6" thick void material under the porch slab. Cantilever the structural porch slab over the added foundation wall to the existing foundation and provide an expansion material. Note that the new porch foundation Q:\LETTERS\lronbridge Homes\lronbridge _Lot 204 _ CovPorchFdn.doc walls and slab should not be connected to the existing Post Tensioned Slab-on-Grade foundation. Refer to Figure 3 for clarification. A representative from this office must observe the repairs to the added porch prior to placement of new concrete. For Option 2 only, the soils engineer of record should be called out to observe the footing placement and the on-site soil conditions for the new foundation walls. If a third party engineer is contacted to observe the foundation walls and structural slab for Option 2, please provide our office with a copy of the approval letter. Please call if you have any questions. Sincerely, Fuhrmann Engineering Services, LLC Reviewed by:' MSP attachment cc: file Q:ILETIERS\Ironbridge Homes\lronbridge _Lot 204 _ CovPorchFdn.doc EXISTING SLAB • 4 LOOSELY COMPACTED SOIL AT CANTILEVERED PORTION OF SLAB EDGE OF FOOTING TO ALIGN WITH EDGE OF EXISTING FOUNDATION 4 1 1/2" EXPANSION JOINT MAT'L (2)-#4 CONT. 4 4 (2)-#4 CONT. 4" CONCRETE SLAB with 4x4-W2.9xW2.9 WIRE WELDED FABRIC. SLOPE AS REQUIRED. 1-- - 6" SLAB VOID~, ·ciTI[T]f -=:I 1.::: 4 (2)-#4 CONT. 4 (2)-#4 CONT. SIGNATURE: Lot: 204 1202-A-3 GENERAL: Legal Address: 0244 Red Bluff Vista Type: Mountain Cottages Plan: 1202 Elev: A Color: 3 Lender Info: Orientation: Release: 0 Type: F/P Seq.: 60 Lot Size: 6,430 Home Size: 2,163 SIGNATURE DATES Wednesday, August 01, 2007 Wednesday, August 01, 2007 .l REPORT I OWNER INFORMATION KEY DATES: Name: Karla & Cheryl Allen Agreement Date: 4/2112007 Address: PO Box 3863 ProjectedCiose: 6/2112007 City: Basalt Closed: 6/2112007 State: Co Construction Start: 7/23/2007 Zip: 81621 Home 927-7089 Home Review: Fax 927-1119 Walkthrough: DS 1: 7/23/2007 DS2: DS3: J Page I of2 Lot: 204 1202-A-3 DESIGN OPTIONS: ARCHITECTURAL OPTIONS Option Covered Rear Porch (Mountain Cottages Only) 1202 Optional 2nd Floor Plan (Paint Grade) CHANGE ORDERS: co# Date Description COMMENTS: VVednesday,August01,2007 REPORT Qty I Page 2 of2 t06~ No.~~-------------Assessor's Parcel No. ~jq5 .. \ ~-?1-zo:t. Date 9-0S-D-=t-. BUILDING PERMIT CARD . Job Addressm4U e.ect 81UfF 0t~JA?-6Ul5 (lronbrttlqe \)Ut ·l?h1-flqL-c3,LO±~D4) Owner J:.\\f:V), K.OrtO.t eher'll Address BQ<'3B63 tlt,~l± Phone# ___ _ Contractor \\Cl~E.'V\ llin~ Address4l0 '~cnhl~ ·M\OC u~~e #384.-MtO Setbacks: Front Rear RH ____ LH ____ Zoning ___ _ sJF en IDunctottoV\ w[a.t\-qcuaqi~PecTioNs Soils Test --rr~-,...---___..--,.------ Footing ~~ Foundatio~~ Grout v/ Under ground Plumbing 9"--7-oZ~ Rough Plumbing t!-l<t-o7 ?m3 Fram i ng J)-:;1.6"122~ Insulation /l'eJ-tf-r:;]~ ' Roofing __________ _ Drywall /,.} -It:.> ·0 Z~ Gas Piping Jl ·-!lf ·o?~· g'o/~~~ ~~r 7-~~7~ $~~ Weatherproofing ________________ _ Mechanicai _________ --=-....,..........-- Eiectrical Rough (State) F Electrical Final (State) (!.,-;z 7-o I'Jf:: -~inal q7,,.:l..7-o9 /Che list ~C m g.J eted? ~ Certificate 0 cc up an cy # --r-""'-""---'_,::t');::,...=~-=-------­ Date iss'wd ·II· re Septic System # ___________ _ Date __________ _ Final __________ _ Other--------'-------- NOTES (continue on back) .£. INSPECTION WILL NOT BE MADE UNLESS THIS CARD IS POSTED ON THE JOB 24 H OU RS NOTICE REQUIRED FOR INSPECTIONS J~~ BUILDING PERMIT ~D~ GARFIELD COUNTY, COLORADO 1 Date I ssued .9:S:l. ...... Zoned Area ............................... Permit No .... J.~~3. .. .. j AGREEMENT In consideration of the issuance of this permit, the applicant hereby agrees to comply with all laws and regulations rel ated to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above sa id regulations are not fully complied with in the zoning, lo ca tion, erection and construction of the above described structure, the permit ma y then be revoked by notice from the County Building Inspector and IMMEDIAT ELY BECOME NULL AND VOID. ~::~~!~!ti!~Q ~~=~rou ~·w Owner 'l\en-~~\Q~ tWf'tl Contractor t\om.m C'l>lmt• Setbacks Front Side Side Rear This Card Must Be Posted So It is PlA inly Visible From The Street Unt il Final Inspection. INSPECTION RECORD Footing ;/,~ L-n A:_' Driveway Foundation ..t'~ I.-.~· ~.a... ith' Underground Plumbing 9-/--o/~ Insulation //~'P-9-o?~ Rough Plumbing Jl-!t/-o?97¥J.. Drywall /J ·l o --o-7-P»r?- Chimney & Vent /J-?.6-d? w/1--E lec tric Final (by State In spector) Gas Piping 11 _ /tf-o7 PP-Final ;/.·.?-7-o? .():h~~ .d. E lectric Rough (By State ln s p~ /?r-Septic Fina l ~ Framing !1 -!).6 -o l --?lfZ Notes: (To include Roof in place and Windows and Doors in stalled). ALL LISTED ITEMS MUST BE INSPE CTED AND APPROVED BEFORE COV ERING - WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND. THIS PERMIT IS NOT TRANSFERABLE For Inspections Call 384-5003 108 8th Street G le nwood Sp rin gs, Colorado APPROVED DO NOT DESTROY THIS CARD l}i( . Date Q-'S-+ By t:l' J+L V '-\, I F PLA~-COVER WITH CLEAR PLASTIC Parcel Detail Page 1 of3 Garfield County Assessor/Treasurer Parcel Detail Information Assessor/Treasurer Property Search I Assessor Subset Query I Assessor Sales Search Clerk & Recorder Reception Search Basic Building Characteristics I Tax Information Paic~!I>_~tflil I Ya_lue_Detiiil Sales Detail I ResidenJial/Cgmm_eJ:cia!Jmpmy_~l11~nt[ktail Land Detail I Photographs I TaxArea II Account Number II Parcel Number II Mill Levy I I o9o II R043376 II 239512227204 II 67.224 I Owner Name and Mailing Address IALLEN, KARLA & CHERYL I IPO BOX 3863 I !BASALT, CO 81621 I Legal Description lsECT,TWN,RNG: 12-7-89 SUB:IRONBRIDGE IPUD, PHASE II, FILING 1, 2 & 3 ILOT:204 PRE:R004189 BK:l596 PG:871 IBK:J565 PG:600 BK:l560 PG:438 IBK:l560 PG:431 BK:1057 PG:0745 IBK:J028 PG:768 BK:1028 PG:597 IBK:l006 PG:743 BK:1944 PG:399 IRECPT:726961 BK: 1944 PG:398 IRECPT:726960 BK:1822 PG:287 IRECPT:702424 BK:1822 PG:283 IRECPT:702422 BK:1822 PG:250 IRECPT:702421 BK:1782 PG:269 IRECPT:6944 79 BK: 1782 PG:264 IRECPT:694478 BK:1747 PG:1 IRECPT:686745 BK:1218 PG:738 IRECPT:572583 BK:1218 PG:715 http://www. garcoact.com/ assessor/parcel.asp ?ParcelN umber=23 9 51222 7204 8/3/2007 Parcel Detail Page 2 of3 IRECPT:572582 BK: 1217 PG:266 I IRECPT:572131 BK: 1206 PG:852 I IRECPT:569200 BK: 1206 PG:780 I IRECPT:569199 BK:1206 PG:768 I IRECPT:569197 BK:1206 PG:734 I IRECPT:569195 BK:1206 PG:662 I IRECPT:569194 BK:1206 PG:637 I IRECPT:569192 BK:1206 PG:629 I IRECPT:569!91 BK:1206 PG:574 I IRECPT:569190 BK: I 063 PG:0578 I IBK:1063 PG:0571 I Location Physical 1244 RED BLUFF VISTA GLENWOOD SPRINGS' Address: Subdivision: IIIRONBRIDGE PUD, PHASE II, FILING I, 2 & I Land Acres: I 0 Land SqFt: I 6,430 Section II Township II Range I 12 Jl 7 II 89 I Property Tax Valuation Information II Actual Value II Assessed Value I I Land: II 71,56011 20,7501 I Improvements: II Oil 0 I Total: II 71 ,56oll 20,7501 Sale Date: 116/2112007 Sale Price: 11247,100 Basic Building Characteristics Number of Residential 0 Buildings: Number of Commllnd 0 Buildings: No Building Records Found http://www. garcoact.com/assessor/parcel.asp ?ParcelN um ber=23 9 51222 72 04 8/3/2007