December 23, 2014
Eric Williams
44157 Highway 6
Garfield County
RE: Insulation proposal for the Williams Residence, plans dated 6/2/2014 and site visit, 10/22/2014.
INSULATION CERTIFICATE
Vaulted roof , entry and dormers -- 4.5" R31 Average spray applied closed cell rigid polyurethane foam
with R I9 unlaced batt insulation over the foam. R50
Interior partitions -- RI I unfaced batt insulation to designated walls excluding closets and laundry,
Mid -floor- R19 unfaced batt insulation.(upper Icvcl floor)
Box sills and rims at top of foundation level -2" R 13 Average spray applied closed cell rigid polyurethane
foam, to seal + R19 unfaccd batt insulation .R32.
Truss heal -3'' R20, Average spray applied closed cell rigid polyurethane foam to seal eaves exposure.
Foundation crawl space -R1 1 Rated vinyl faced batt insulation with 3.5" pin-up.
Foundation demising walls -2", R 13 Average spray applied closed cell rigid polyurethane foam.
Exterior walls at dormers and walk -out foundation, south wall -2.5" RI7" Average spray applied closed
cell rigid polyurethane foam with 3" Blown -In -Blanket, R13, R30.
Foundation North wall- RI 1 unfaccd batt insulation added to your site installed blue board.
Foam chinking of exterior doors, windows, and plate penetrations.
Regards,
Kerry M. Karnan
PM Division 7 Insulation, Inc.