HomeMy WebLinkAboutE-mail CorrespondenceJim Wilson From: erniekollar@gmail.com on behalf of Ernest Kollar [erniekollar@sopris.net] Sent: Friday, April 26, 2013 11:38 AM To: Jim Wilson Subject: 101 Wood Nymph Place Attachments: S2 Main 4-26-13.pdf; S6 -Details 4-26-13.pdf Jim/ Paco: Per our discussion during the site visit, I am attaching revised drawing sheets S2 (Main Floor) and S6 (Details) that address the following areas: 1. The revisions that were made to the steel at the living room. 2. The corner post at the entry was omitted. The cantilevered 3-11 7/8" LVL beam is capable of carrying the load but the "K" hanger is inadequate. Detail 13/S6 shows a bracket that will enhance the capacity of the connection. 3. In the mechanical room, holes for a gas line were drilled too close to the bottom of several rafters. Please install LSTA12 straps to the bottom of the rafters. Keep nails at least 2 inches away from the edge of hole on each side. 4. Detail 12/S6 shows a new 4 ft. x 6 ft. shed roof along the back, supported with a beam/brace system. This has not yet been constructed. Please call with any questions. Ernie Ernest Kollar Engineers, Inc. 320 Main Street, Suite 203 Carbondale, CO 81623 (970) 963-3223 phone erniekollar(a�sopris.net 1