Loading...
HomeMy WebLinkAboutApplication-PermitProject Address 0360 CR 225 RIFLE, CO Owner Information Garfield County Building & Planning Department 108 Bth Street Suite 401 Glenwood Springs, CO 81601 - Phone: (970)945-8212 Fax: (970)384-3470 Parcel No. Subdivision emit No Permit Type Residential Bwldtng Work Classification. New Permit Status: Active issue Date: 4/14/2010 Section Expires: 10/11/2010 Township Range 217906400071 6 6 92 Address Phone Cell Terry Davis 074 CR 225 Rifle CO 81650 970-625-9160 Contractor(s) Phone Primary Contractor Proposed Construction! Details Single family dwelling with attached garage and covered/uncovered decks. FEES DUE Fee Amount Plan Check Fee $1,617.82 Residential Building Fee $2,488.95 Total: $4,106.77 Valuation: $ 366,190.68 Total Sq Feet: 6424 FEES PAID Inv Total Paytype Amt Paid Amt Due Inv # BLRE-11-09-19904 $ 4,106.77 Check # 1507 Credit Card $2,485.31 $1,621.46 $ 0.00 Required Inspections: For Inspections call : 1(970)384-5003 inspection IVR See Permit Record Building Department Copy Wednesday, April 14, 2010 GARFIELD COUNTY BUILDING PERMIT APPLICATION 108 8th Street, Suite 401, Glenwood Springs, Co 81601 Phone: 970-945-8212 / Fax: 970-384-3470 / Inspection Line: 970-384-5003 www.2,arfield-eountv.com 1 ,, Parcel No: (this information is available at the assessors office 970-945-9134) Z , 7 ?496,4 Q 7 / � //���-4CD oh A dress: (if an address has not b_een�rassigned, please provide Cr, ,/Hwy yoorr Sire,el Name & City) or and legal description 3 Lot No: Block No: Subdi Exemption: 4 Owner: (property owner) iz y rDAUI S Mailing Address:/Ph: o 71 Psi. 2-2,5(Z(i 9 --62,S=Y14,0 Alt Ph; • y',0 -3e70 --54 ) 5 Contractor: ID t. Mailing Ad ress:_ ... Ph: Alt Ph: Const Type: F•6* , Zoning: R„. BLDG DEPT: 6 Architect / Engineer: Mailing Address: Ph: Alt Ph: 7 Sq. Ft. of Building: ' Sq. Ft. or Acres of Lot: 4(9 S Height: Z3 d No. of Floors: 8 Use of Building: — , SI"J916- /- 1 e Wrrc 9 Describe Work: 10 Class 6f Work: jgNew _ ❑ Alteration o Addition 11 Garage: Attached c Detached Septic: -r ISDS o Community 12 Driveytiay„P git 2 ((, -609-p- Owners valuation of Work: $ ltd s/® ori Authority. This application for a Building Permit must be signed by letter of authority, signed by the Owner. must be provided A Building Permit cannot be issued without proof of legal NOTICE / the Owner of the property. described above, or an authorized agent. If the signature below is not that of the Owner, a separate with this Application. and adequa:e access to the property for purposes of inspections by the Building Department Electrical Permit, (2) County ISDS Permit, (3) another permit required for use on the property identified above, e.g, State or Discharge Permit is not commenced within 180 days of the date of issuance and if work is suspended or abandoned for a period of 180 CERTIFICATION contained above is true and correct. I understand that the Building Department accepts the Application, along with the plans based upon my certification as to accuracy. a Building Permit will be issued granting permission to nte, as Owner, to construct the structure(s) and facilities detailed on and my agents will comply with provisions of any federal, state or local law regulating the work and the Garfield County Building I acknowledge that the Building, Permit may be suspended or revoked, upon notice from the County, if the location, are not in compliance with County Regulation(s) or any other applicable law. described above, to inspect the work. I further acknowledge that the issuance of the Building Permit does not prevent the if any, discovered after issuance, or (2) stopping construction or use of the structure(s) or facility(ies) if such is in violation work by the Building Department do not constitute an acceptance of responsibility or liability by the County of errors, Omissions compliance with federal, state and local laws and County Regulations rest with me and my authorized agents, including without THE NOTICE & CERTIFICATION ABOVE: c_efixy .2_,/0 -- DATE Leval Access. Other Permits. Multiple separate permits may be required: (3) State County Highway/ Road Access or a State Wastewater Void Permit. A Building Permit becomes null and void if the work authorized days after commencement, I hereby certify that I have read this Application and that the information and specifications and other data submitted by me or on my behalf (submittals), Assuming completeness of the submittals and approval of this Application, the submittals reviewed by the Building Department. In consideration of the issuance of the Building Permit, I agree that 1 Code, ISDS regulations and applicable land use regulations (County Regulation(s)). construction or use of the structure(s) and facility(ies), described above, 1 hereby grant permission to the Building Department to enter the property, Building Official from: (1) requiring the correction of errors in the submittals, of County Regulation(s) or any other applicable law. Review of this Application, including submittals, and inspections of the or discrepancies. As the Owner, I acknowledge that responsibility for limitation my architect designer, engineer and/ or builder. I HEREBY ACKNOWLEDGE THAT I HAV EAD ANDUNDERSTAND OWNER NATURE STAFF USE ONLY Special Conditions: Adjusted Valuation: Saco NO, 03 Plan Check Fee: 1647 .g).2. Permit Fee: /207a-615 Manu home Fee: Misc Fees: ISDS Fee: 11-71.60 Total Fees: 4171.70(P2--).4(19 Fees Paid: Balance Due: s's'`8.1 f BP No & Issue Date: ISDS No & Issued Date: - '7 t -1319 Setbacks: OCC Group: (1Z0 Const Type: F•6* , Zoning: R„. BLDG DEPT: r PLNG DEP : • APPROVAL DATE APPR VAL DATE The following items are required by Garfield County for a final Inspection: 1) A final Electrical Inspection from the Colorado State Electrical Inspector. 2) Permanent address assigned by Garfield County Building Department and posted at the structure and where readily visible from access road. 3) A finished roof; a lockable building; completed exterior siding; exterior doors and windows installed; a complete kitchen with cabinets, sink with hot & cold running water, non-absorbent kitchen floor covering, counter tops and finished walls, ready for stove and refrigerator; all necessary plumbing. 4) All bathrooms must be complete, with washbowl, tub or shower, toilet, hot and cold running water, non-absorbent floors, walls finished, and privacy door. 5) Steps over three (3) risers, outside or inside must be must have handrails. Balconies and decks over 30" high must be constructed to all IBC and IRC requirements including guardrails. 6) Outside grading completed so that water slopes away from the building; 7) Exceptions to the outside steps, decks, grading may be made upon the demonstration of extenuating circumstances., i.e. weather. Under such circumstances A Certificate of Occupancy may be issued conditionally. 8) A final inspection sign off by the Garfield County Road & Bridge Department for driveway installation, where applicable; as well as any final sign off by the Fire District, and/or State Agencies where applicable. A CERTIFICATE OF OCCUPANCY (C.O.) WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. A C.O. MAY TAKE UP TO 5 BUSINESS DAYS TO BE PROCESSED AND ISSUED. OWNER CANNOT OCCUPY OR USE DWELLING UNTIL A C.O. IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. I understand and agree to abide by the above conditions for occupancy, use and the issuance of a C.O. for the building identified in the Building Permit. OWNE GNATURE Bapplicati blfdecember2007 Building Plan Review Description of Work: Single family dwelling with attached garage and covered/uncovered Bin #: E-3 Location Address: 000074 CR 225 RIFLE, CO General Information Contacts Case Manager: Ken Smith Plan Case Number: BLDG -II -09-6214 Parcel: 217906400071 Application Date: 11/23/2009 Owner: Terry Davis Applicant: Terry Davis Applicant Phone: 970-625-9160 Email: Building Planning/Zoning Engineered Foundation Property Line Setbacks Driveway Permit 30ft Stream Setbacks Surveyed Site Plan Flood Plain Septic Permit and Setbacks Building height Grade/Topography 30% Toning Sign -off Attach Residential Plan Review List Road Impact Fees Minimum Application Questionnare HOA/DRC Approval Subdivision Plat Notes Grade/Topography 40% Fire Department Review Planning Issues Valuation Determination/Fees Subdivision Plat Red Line Plans/Stamps/Sticker General Comments: Attach Conditions 416t A1)." # 74, e y 32060.68 F i 7e A r G Application Signed 2 j X 4 j Plan Reviewer To Sign Application G i 6*-" 2 f X30, Parcel/Schedule No. --VC) Diablit - .?,4;& , `Ct` 40# Snowload Letter - Manu. Homes Soils Report Tuesday, November 24, 2009 GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS For SINGLE FAMILY DWELLING CONSTRUCTION Including NEW CONSTRUCTION ADDITIONS ALTERATIONS And MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. When reviewing a plan and it's discovered that required information has not been provided by the applicant, this will result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor shall be required to provide this information before the plan review can proceed. Other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. TWO (2) SETS OF CONSTRUCTION DRAWINGS & TWO (2) SITE PLANS MUST BE SUBMITTEDFOR ALL APPLICATIONS. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. Any project with more than ten (10) occupants requires the plans to be sealed by a Colorado Registered Design Professional. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following checklist prior to and during design. Applicants are required to indicate appropriately and to submit the completed checklist at time of application for a permit. Plans to be included for a Building Permit, must be o,n drafting paper at least 18"x24" and drawn to scale. 5. Have you provided any RESOLUTIONS and/ or LAND USE PERM1T(S) associated with this property? Yes if Yes please provide a COPY. No t- 6. Are you aware that prior to submittal of a building permit application you are required to show proof of a legal and adequate access to the site? This may include (but is not limited to) proof of your right to use a private easement/right of way; A County Road and Bridge permit; a Colorado Dept. of Highway Permit, including a Notice to Proceed; a permit from the federal government or any combination. You can contact the Road & Bridge Department at 625-8601. See phone book for other agencies Yes 7. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordan9e with the IRC or per stamped engineered design? Yes 8. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and earth? Yes v No 9. Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces and soffits? Yes ✓ No 10. Do the plans include design loads as required by Garfield County for roof snow loads, (a minimum of 40 pounds per square foot up to & including 7,000 feet above sea level), floor loads and wind loads? Yes 11. Does the plan include a building section drawing indicating foundation, wall, floor, and roof construction Yes 12. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or joists or trusses? Yes / 13. Does the building section drawing or other detail include the method of positive connection of all columns and beams? Yes ✓ 14. Does the elevation plan indicate the height of the building or proposed addition from the undisturbed grade to the midpoint between the ridge and eave of a gable or shed roof or the top of a flat roof? (Building height measurement usually not to exceed 25 feet) Yes 3 25. Do you understand that the minimum dimension a home can be on a lot is 20ft.wide and 20ft. long? Yes k 26. Have you designed or had this plan designed while considering building and other construction code requirement Yes 27. Do your plans comply with all zoning rules and regulations in the County related to your properties zone district? Yes 28. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by the Garfield,.County Building Department? Yes 29. Do you understand that approval for design and/or construction changes are required prior to the application of hese changes? Yes t/ 30. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application submittal and that you will be required to pay the "Permit l=ee" as well as any "Road Impac " r "Septic System" fees required, at the time you pick up your building permit? Yes 31. Are you aware that you must call in for an inspection by 3:30 the business day before the requested inspection in order to receive it the following business day? Inspections will be made from 7:30 a.m. to 3:30 p.m. Monday through Friday. Inspections are to be called in to 384-5003. Yes V No 32. Are you aware that requesting inspections on work that is not ready or not accessible will result in a $50.00 re -in pection fee? Yes 33. Are you aware that you are required to call for all inspections required under the IRC including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of the building? Yes 5 Project Name: Project Address: Notes: 22-r If any required information is missing delays in issuing the permit are to be expected. Work may not proceed without the issuance of a permit. If it is determined by the Building Official that additional information is necessary to review the application and plans to determine minimum compliance with the adopted codes, the application may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review, delay in issuance of the permit or delay in proceeding with construction. bpm inregsfMar2009 7 LAND USE CHANGE PERMIT for An Accessory Dwelling Unit located at 0074 County Road 225, Rifle, CO Parcel Number: 2179-064-00-071 In accordance with and pursuant to Sections, 4-104 and 7-801 of the Garfield County Unified Land Use Code of 2008 the Director of Building and Planning hereby authorizes, by Administrative Permit, GAPA 6265, the following activity: An Accessory Dwelling Unit located at 0074 County Road 225, Rifle, Garfield County, Colorado The Administrative Permit is issued subject to the conditions set forth in Exhibit A (attached hereto), and shall be valid only during compliance with such conditions and other applicable provisions of the Garfield County Unified Land Use Code, Building Code, and other regulations of the Board of County Commissioners of Garfield County, Colorado. BUILDING AND PLANNING DEPARTMENT, GARFIELD COUNTY, COLORADO Fred Jarman, AICPV Director of Building and Planning I/ / l0/4) Date EXHIBIT A 0074 County Road 225, Rifle, CO 1. The leach field for the proposed residence may be located north of the Cactus Valley Ditch as shown in Exhibit Al . However, if this location is found not to be suitable then the ISDS system shall be located at another location on-site provided it meets all local and state ISDS requirements. 2. All representations of the applicant within the application shall be considered conditions of approval unless otherwise modified by the Determination of the Director. 3. All lighting associated with the ADU shall be the minimum amount necessary. All exterior lighting shall be shielded to prevent light trespass on any adjoining property and be downward facing towards the structure. 4. The Applicant shall meet all requirements of the Garfield County Unified Land Use Resolution of 2008, as amended and shall meet all building code requirements. 5. The accessory dwelling unit shall not be conveyed as a separate interest but may be leased. 6. The gross floor area for the ADU shall not exceed 1,500 square feet. 7. All construction of the new residence on-site to meet the current Garfield County building codes, state, and federal requirements. 8. A driveway permit shall be required for the new residence. The driveway access permit shall be issued with conditions specific to the driveway access location, 9. All vehicles hauling equipment and materials for this application shall abide by Garfield County's oversize/overweight permit system. All vehicles requiring oversize/overweight permits shall apply for them at Garfield County Road and Bridge. a E April 1, 2010 Terry and Victoria Davis 0074 CR 225 Rifle, CO 81650 Garfield County BUILDING & PLANNING DEPARTMENT Re: Request for Administrative Approval for an Accessory Dwelling Unit, GAPA-1-10- 6265 Dear Mr. and Mrs. Davis, Please find enclosed the General Administrative Permit Request (staff report) and Director Determination for an Accessory Dwelling Unit located at 0074 CR 225, Rifle, Colorado. As of April 1, 2010 the Director issued a Determination conditionally approving the request. As per Unified Land Use Resolution of 2008, as amended, Section 4-104 (B) (1), "The applicant or adjacent property owner affected by the decision may request reconsideration of the Director's decision by the Board of County Commissioners. The requesting party may file a written request within ten (10) calendar days of the date of written notice of the decision by the Director. The Board of County Commissioners shall review the request at the next regular meeting of the Board and set a public hearing by a majority vote of the Board in favor of said hearing." The Board may also call-up the application. The call-up period ends April 11, 2010. The permit will be approved on April 12, 2010, if no public hearing is set for reconsideration. Please feel free to call me with any questions you may have regarding any questions. Sincerely, Molly Orkild=Larson, AICP, RLA Senior Planner 970.625.5903 108 Eighth Street, Suite 401 • Glenwood Springs, CO 81601 (970) 945-8212 • (970) 285-7972 • Fax: (970) 384-3470 BUILDING & PLANNING DEPARTMENT April 1, 2010 Terry and Victoria Davis 0074 County Road 225, Antler Lane Rifle, CO 81650 DIRECTOR DETERMINATION Accessory Dwelling Unit at 0074 County Road 225, Antler Lane Garfield County Pile Number GAPA 1-10-6265 Dear Mr. and Mrs. Davis, This letter is provided to you as the owner / applicants of 0074 County Road 225, Antler Lane. A request for an Administrative Permit for an Accessory Dwelling Unit has been reviewed and a Director Determination is issued approving the permit subject to the following conditions: 1. The leach field for the proposed residence may be located north of the Cactus Valley Ditch as shown in Exhibit A. However, if this location is found not to be suitable then the ISDS system shall be located at another location on-site provided it meets all local and state ISDS requirements. 2. All representations of the applicant within the application shall be considered conditions of approval unless otherwise modified by the Determination of the Director. 3. All lighting associated with the ADU shall be the minimum amount necessary. All exterior lighting shall be shielded to prevent light trespass on any adjoining property and be downward facing towards the structure. 4. The Applicant shall meet all requirements of the Garfield County Unified Land Use Resolution of 2008, as amended and shall meet all building code requirements. 5. The accessory dwelling unit shall not be conveyed as a separate interest but may be leased. 6. The gross floor area for the ADU shall not exceed 1,500 square feet. 7. All construction of the. new residence on-site to meet the current Garfield County building codes, state, and federal requirements. 1 108 Eighth Street, Suite 401 • Glenwood Springs, CO 81601 (970) 945-8212 • (970) 285-7972 • Fax: (970) 384-3470 8. A driveway permit shall be required for the new residence. The driveway access permit shall be issued with conditions specific to the driveway access location. 9. All vehicles hauling equipment and materials for this application shall abide by Garfield County's oversize/overweight permit system. All vehicles requiring oversize/overweight permits shall apply for them at Garfield County Road and Bridge. The Board of County Commissioners may call-up the application for review within 10 calendar days. The timeframe commences from the date of determination. The Administrative Permit will be issued upon expiration of that time if no request for further consideration is received. Sincerely, Fred Jarman, AICP Director of Building and Planning cc: File 2 [METER LS 38572 ON MING THE JD FORG PROPOSED GRAVEL f 1,0 v EXHIBIT A 494.00 5493.00 _ .� FIRST FLOOR EL a 5495.00 SECOND FLOOR EL 5505.15 RIDGE EL a 5519.05 h49gtiZ~ f i iSAb. � yf cirr L re s-f$a ▪ i 56�g. // 1 3'Tg*D60- ` 5-18e 0 10 GRAPHIC SCALE z0 40 00 ( IN FEET ) 1 tache 20 ft. NOTES 11 DATE OF SURVEY; APRIL 14, 2009 AND JANUARY 12.2010 Davis ADUIMOL April 1, 2010 GENERAL ADMINISTRATIVE PERMIT REQUEST 1. REQUEST Terry and Victoria Davis request a permit for an Accessory Dwelling Unit (ADU) in the Rural Zoning District at 0074 County Road 225, Antler Lane, Rifle, CO. 2. DESCRIPTION OF THE PROPOSAL The applicant requests an Administrative Permit to allow for an Accessory Dwelling Unit (ADU) at 0074 County Road 225, Antler Lane, Rifle, CO. Under this application, the existing residence is designated as the ADU and a new residence will be built on the north side of the 40 acre property. The ADU contains less than 1,500 square feet of finished floor area and the minimum lot size requirement has been met. The water supply for the ADU and proposed residence will be provided via a spring located on the property. In a report by Resource Engineering Inc., it states that the spring's water quality is suitable for domestic and irrigation uses and the quantity is more than adequate to meet the demands of existing uses and a new residence on the property. An Individual Sewage Disposal System (ISDS) is proposed for the new residence and the existing residence is presently accommodated by an ISDS system. A revised location of the ISDS system for the proposed residence is illustrated in Exhibit A. The proposed residence is situated north of the Cactus Valley Ditch which is owned and operated by the Grand River Ditch Company. A letter from the ditch company's representative, Neil Goluba, requests "that any County approval of the Davis' Application be conditioned upon the Davis' executing an agreement with the Ditch Company defining the historic setbacks established for the Ditch." This letter also states that the ditch does not have a "specifically defined" easement. See Exhibit F. The Applicant's revised site plan indicates at least a 20 foot separation between the ditch and proposed residence and leach field, a distance capable of accommodating an easement if so desired. See Exhibit A. The County believes that the delineation of a ditch easement and agreement on this property is a matter between the property owners and Ditch Company, and not the County. 3. APPLICABLE REGULATIONS The Land Use Table contained in Article III of the Land Use Resolution of 2008, as amended designates an ADU as a Use Permitted Subject to Administrative Review. Section 7-801 stipulates requirements that must be met in order to apply for the General Administrative Permit. Those requirements include a minimum lot size of two (2) acres or twice the minimum lot size in zone districts where the minimum lot size is less than two (2) acres. The subject property is 40 acres therefore compliant with this requirement. In addition, the maximum square footage for an ADU in the Rural zone district is 1,500 square feet which is not exceeded in the current request. Davis ADU/MOL April 1, 2010 Section 4-104 stipulates the Administrative Review Process and Section 7-801 provides applicable standards for an ADU. All requirements have been met, including the requirement for notice to the adjacent properties which the applicant has completed by submitting certified return receipts for that notice. 4. REFFERAL AGENCY COMMENTS Garfield County Road and Bridge — This department does not have any objections to this application and also provides some additional comments. See Exhibit B. City of Rifle Fire Protection District — It is the policy of the Rifle Fire Protection District to review parcels of land that contain three (3) or more homes for fire code compliance. Since this parcel does not meet this requirement, only recommendations are provided by this agency. See Exhibit C. Adjacent Neighbors — Two neighbors, John and Nila Parrington and Edith Goldman, provided a letter and phone call, respectively, in support of the Applicant's ADU application. See Exhibits D and E. Grand River Ditch Company (represented by Neil W. Goluba, Goluba & Goluba P.C.) — The ditch company requests that the County make as a condition of approval of this application for the Davis' to execute an agreement with the ditch company defining the historic setbacks established for the ditch. See Exhibit F. 5. RECOMMENDATION Staff finds that the proposed ADU is in compliance with Article III, Sections 4-104, 4-501 and 7-801 of the Garfield County Unified Land Use Resolution of 2008, as amended and recommends that the Director approve the General Administrative Permit to allow an ADU on a property legally described as 0074 County Road 225, Antler Lane, Rifle, CO with the following conditions: 1. The leach field for the proposed residence may be located north of the Cactus Valley Ditch as shown in Exhibit A. However, if this location is found not to be suitable then the 1SDS system shall be located at another location on-site provided it meets all local and state ISDS requirements. 2. All representations of the applicant within the application shall be considered conditions of approval unless otherwise modified by the Determination of the Director. 3. All lighting associated with the ADU shall be the minimum amount necessary. All exterior lighting shall be shielded to prevent light trespass on any adjoining property and be downward facing towards the structure. 4. The Applicant shall meet all requirements of the Garfield County Unified Land Use Resolution of 2008, as amended and shall meet all building code requirements. 5. The accessory dwelling unit shall not be conveyed as a separate interest but may be leased. 6. The gross floor area for the ADU shall not exceed 1,500 square feet. 2 Davis ADU/MOL April 1, 2010 7. All construction ofthe new residence on-site to meet the current Garfield County building codes, state, and federal requirements. 8. A driveway permit shall be required for the new residence. The driveway access permit shall be issued with conditions specific to the driveway access location. 9. All vehicles hauling equipment and materials for this application shall abide by Garfield County's oversize/overweight permit system. All vehicles requiring oversize/overweight permits shall apply for them at Garfield County Road and Bridge. 3 ( PROPOSED GRAVEL 5493,00 IAMETER LS 36572 ON !KING THE ER FOR 10 7 C �r 28' SETBACK ELE,C & TELE WATER LINE 4g7" 2600 5491,00 S W o FIRST FLOOR EL a 5495.00 SECOND FLOOR EL - 5505.15 RIDGE EL a 5519.06 F091.0 GONG ?Nilo \s+e ��oo 1� gpa � 5 J -�� ��'a9boo c GRAPHIC SCALE m B B m 'w BO ( IN FEET ) 1. inch 20 [t. NOTES 11 DATE OF SURVEY. APRIL 14, 2009 AND JANUARY 12,2010 GARFIELD COUNTY Building & Planning Department Review Agency Foran Date Sent: February 22, 2010 Comments Due: Requested Name of application: Terry and Victoria Davis ADU Sent to: Garfield County Road & Bridge Garfield County requests your comment in review of this project. Please notify the Planning Department in the event you are unable to respond by the deadline_ This form may be used for your response, or you may attach your own additional sheets as necessary. Written comments may be mailed, e-mailed, or faxed to: Garfield County Building & Planning Staff Contact: Molly Orkild-Larson 109 8th Street, Suite 301 Glenwood Springs, CO 81601 Fax: 970-384-3470 Phone: 970-945-8212 General Comments: Garfield County Road and Bridge Department has no objections to this application with the following comments. _ A driveway access peinit shall be required for this location. The driveway access permit shall be issued with conditions s ecific to the drivewa access location. The added traffic load created by this application will not have an impact on the total traffic volume on Cr. 225. All vehicles hauling equipment and materials for this application shall abide by Garfield County's oversize/overweight permits system. All vehicles requiring oversize/overweigh permits shall apply for theme at Garfield Conn Road and Bridge Department. Name of review agency: Garfield Count Road and Brid e De artment By: Jake B. Mall Date March 1, 2010 Revised 3/30/00 Moll ` OrkiId-Larson From: Kevin Whelan tkewhelan@riflefiredept.orgj Sent: Friday, March 19, 2010 10:14 AM To: Molly Orkild-Larson Subject: Davis ADU - Permit # BLRE-11-09-1378 Molly, The Rifle Fire Protection District has recently reviewed the proposed Davis ADU- permit # BLRE 11-09-1378. The property is located at 074 CR 225. It is the District's understanding that the intent is to add a single ADU on a 40 acre parcel that also has one other primary residence. The District's policy is to review parcels of land that contain three of more homes for fire code compliance. Since this parcel does not meet this, the following are recommendations only. The proposed subdivision is within the boundaries of the Rifle Fire Protection District and fire and emergency medical services are provided by the District. In order to improve our ability to provide these services, the District makes the following recommendations: 1. Fire protection water is recommended for the site. Without dedicated fire protection water our ability to fight a fully involved structure fire in this area is limited. The fire district does have some ability to transport water to the site. 2. Posting of addresses: Addresses are to be posted where the driveway intersects with the County Road as well as on the individual homes and / or where single drives intersect with the shared driveway. Letters are to be a minimum of 4 inches in height, 1/2 inch in width and be in contrast to background colors. 3. Individual propane tanks are to be placed in a location where they are not subject to damage and combustible materials are to be kept a minimum of 10 feet away from tanks. 4. Vegetation should be removed from near any structures to provide a safe area in the event of a wild land fire. 5. Roadways: Consideration should be given to the heavy weights, widths and heights of emergency apparatus when constructing driveways. Driveways should be of an all weather -driving surface. Again, these are only recommendations to the property owners. Feel free to contact me if I can be of further assistance or there are any questions. Sincerely, Kevin C. Whelan Fire Marshal Rifle Fire Protection District "The Mission of the Rifle Fire Protection District to to Enhance Health and Safety and to Protect the Life , Home and Property of the People We Serve" f TALLY HO RANCH, LLC 0145 County Road 225 Rifle, CO 81650 970-625-0208 FAX: 970-625-8636 tallyhoconst a.sopris.net March 20, 2010 Garfield County Pluming Department Attention: Ms. Molly Orkild-Larson Garfield County Plaza Building 108 Eighth Street, Suite 401 Glenwood Springs, CO 81601 Re: Request for Administrative Pennit for an Accessory Dwelling Unit Applicant: Teny and Victoria Davis Dear Ms. Orkild-Larson: We are writing this in support of our neighbors, Terry and Tori (Victoria) Davis. Ever since they moved to Antlers Lane, they have been good neighbors to us and others. They keep their place neat and alltactive, and help out their neighbors whenever they can, including snow plowing drive- ways or mowing the next door lady's lawn when she couldn't get to it. We think the County should allow Terry and Tori an accessary dwelling on their property. The County allowed us to subdivide our property so our children could have land on which to build their homes. The land to the south of Davis's has two houses on it, and it is a much smaller parcel than Davis's 40 acres. Our neighbors to the north of us, the Fraser's got permission from the County to put in an arena facility. The neighbors to the north of the Fraser's received permission from the County to build a metal building with living space in it before they built their new house. So, you can see the County has been very flexible with us and our other neighbors in the past, and should allow Terry and Tori Davis the same consideration. JKP:np John and Nila Parrington xc: Ms. Molly Orkild-Larson, Garfield County Planning Dept., 0375 County Road 352, Building 2060, Rifle, CO 81650 Phone Conversations Date: February 24, 2010 Conversation Between: Edith Goldman and Molly Orkild-Larson RE: Terry and Victoria Davis ADU Application Discussion: Mrs. Goldman called to say that the Applicants are good neighbors. They have helped her with snow plowing and putting up a fence. She also has no problem/issues with the ADU they're proposed. NICHOLAS W, GOLUBA GOLUBA & GOLUBA P.C. ATTORNEYS AT LAW US BANK BUILDING I901 GRAND AVENUE, SUITE 206 P.O. BOX 931 GLENWOOD SPRINGS, CO 81602 (970) 945-9141 (970) 945-9143 (Fax) February 19, 2010 Garfield County Building and Planning Department Attn: Molly Orkild-Larson 0375 CR 352, Building 2020 Rifle, CO 81650 Re: Application of Terry Davis 0074 CR 225, Rifle, Colorado Dear Mrs. Orkild-Larson: NEIL W. GOLUBA This firm represents the Grand River Ditch Company which owns and operates the Lower Cactus Valley Ditch (the "Ditch"). It is my understanding that Terry Davis has applied to obtain approval of an Accessory Dwelling Unit on his property located at 0074 CR 225, Rifle, Colorado. The Ditch traverses the Property and the Ditch Company is concerned about possible encroachments into the Ditch right-of-way. The easement for the Ditch as it traverses the Property is historic in nature and not specifically defined. The Davis' cannot construct or place any improvements within the historic Ditch right-of-way. In order to avoid future conflicts between the Ditch Company and the Davis' or future land owners, the Ditch Company proposes that the parties enter into a written agreement establishing reasonable setbacks from the Ditch which correspond to the historic right-of-way used by the Ditch Company. The agreement would provide that no structures shall be constructed within 25 feet of the centerline of the Ditch and no fences, trees, shrubs, and landscaping (other than grass or lawn) shall be placed within 15 feet of the centerline of the Ditch. A proposed form of agreement is attached hereto. In order to protect the Ditch Company's rights and avoid future conflicts, the Ditch Company requests that any County approval of the Davis' Application be conditioned upon the Davis' executing an agreement with the Ditch Company defining the historic setbacks established for the Ditch. The Ditch Company also requests a copy of the submittal packet associated with the Davis Application and to be notified of any further proceedings in connection therewith. C:5ClientlGrand River Ditch\Letter12-19-10 GarCo Bld and Pian.wpd Garfield County Building and Planning Department Attn: Molly Orkild-Larson February 19, 2010 Page 2 Thank you for your consideration of this matter. Please contact me with any questions you may have. Very truly yours, IIfVi. GO /jams f, NW G/alb cc: Grand River Ditch Company C:\Client1Grand River Ditrhllalter12-19-10 GarCa AM and Plan.wpd AGREEMENT THIS AGREEMENT is made and entered into by and between GRAND RIVER DITCH COMPANY (the "Ditch Company") and ("Owner"). RECITALS A. is the owner and developer of (the "Property"). B. The Ditch Company is the owner of the Lower Cactus Valley Ditch, also known as the Grand River Ditch (the "Ditch"), which traverses the Property. C. Owner plans to construct an additional dwelling unit on the Property. D. The parties have reached an Agreement regarding restrictions to be imposed on the Property in order to protect the Ditch Company's historic use and maintenance of the Ditch and are desirous of reducing their Agreement to writing. AGREEMENT NOW, THEREFORE, for and in consideration of the promises, covenants and agreements herein contained, the sufficiency of which is hereby acknowledged, the parties agree as follows: 1. Existing Easement. The parties recognize and agree that the Property is burdened by a valid preexisting and lawful easement and right-of-way for the Ditch and the use, operation, maintenance and repair of the Ditch. The parties agree that nothing contained herein shall be construed to alter or otherwise restrict the Ditch Company's prior and continuing right to operate, maintain and repair the Ditch in accordance with past and historic practices. 2. Setbacks. Owner hereby agrees that no building, shed, garage or other structure shall be constructed within twenty-five (25) feet of the centerline of the Ditch as it traverses the Property and no fences, gates or other improvements, including without limitation, trees, shrubs or landscaping (other than grass or lawn) may be placed, maintained or permitted within fifteen (15) feet of the centerline of the Ditch as it traverses the Property. Notwithstanding the foregoing, the Ditch Company shall have no obligation to restore or repair damage to any grass or lawn area maintained within the fifteen (15) foot setback occasioned by the Ditch Company's maintenance and operation of the Ditch. 3. Ditch Company Rights and Liabilities. The parties acknowledge that this Agreement does not amend or alter the existing and historic rights, responsibilities and liabilities of the Ditch Company relating to or arising from the operation and maintenance of the Ditch in its existing lawful easement. 4. Default. Should Owner or its successor in interest breach this Agreement in any manner, the Ditch Company shall be entitled to damages and costs, including reasonable attorney's fees incurred in enforcing the provisions of this Agreement. 5. Payment of Fees. Owner agrees to reimburse the Ditch Company for one --half (1/2) of all fees or costs, including attorney's fees, incurred by the Ditch Company in connection with this Agreement, including the drafting of this Agreement. 6. Amendments or Modifications. No amendment or modification to this Agreement shall be valid or binding unless expressed in writing, executed by the parties. 7. Entire Agreement. This Agreement constitutes the entire and complete understanding and agreement of the parties pertaining to the subject matter hereof and supersedes any and all prior contemporaneous agreements or understandings in connection with the subject matter hereof. 8. Recording and Binding Effect. This Agreement shall be recorded in the records of the Garfield County Clerk and Recorder and shall run with the Property and be binding upon and inure to the benefit of the parties and their respective successors and assigns. IN WITNESS WHEREOF, the parties have executed this Agreement this day of , 2010. OWNER GRAND RIVER DITCH COMPANY By: By: Alvin Hansen, President By: QSCIie thGrand Rivcr NultAgrecmeni.sample.wpd 2 STATE OF COLORADO ) ) ss. COUNTY OF ) The foregoing Agreement was acknowledged before me this day of , 2010, by , Owner. Witness my hand and official seal. My commission expires: STATE OF COLORADO ) COUNTY OF GARFIELD ) ss. Notary Public The foregoing Agreement was acknowledged before me this day of , 2010, by Alvin Hansen, as President of the Grand River Ditch Company. Witness my hand and official seal. My commission expires: CACIienL Grand River DIRIAAgrconcnl.sample.wpd 3 Notary Public HEPWORTH-1PAWLAK GEOTECHNICAL Hepn'orth-Pawlak Geotechnical, Inc. 5020 Count}- Road 154 Glenwood Spuings, Colorado 81601 Phone: 970-945-7988 Fax: 970-915.8454 email: hpgeo@hpgeotech.com SUBSOIL STUDY FOR FOUNDATION DESIGN PROPOSED DAVIS RESIDENCE 0074 COUNTY ROAD 225 GARFIELD COUNTY, COLORADO JOB NO. 109 039A MARCH 6, 2009 PREPARED FOR: TERRY AND TORI DAVIS c/o CIMARRON LAND AND HOMES, LLC. ATTN: BILL WILDE 73 SIPPERELLE DRIVE BATTLEMENT MESA, COLORADO 81635 Parker 303-841-7119 0 Colorado Springs 719-633-5562 • Silverthorne 970-468-1989 TABLE OF CONTENTS PURPOSE AND SCOPE OF STUDY - I - PROPOSED CONSTRUCTION I - SITE CONDITIONS - 2 - FIELD EXPLORATION - 2 - SUBSURFACE CONDITIONS - 2 - DESIGN RECOMMENDATIONS - 3 - FOUNDATIONS - 3 - FLOOR SLABS - 4 - UNDERDRAIN SYSTEM.. - 5 - SURFACE DRAINAGE - 5 - LIMITATIONS - 6 - FIGURE 1 - LOCATION OF EXPLORATORY BORINGS FIGURE 2 - LOGS OF EXPLORATORY BORINGS FIGURE 3 - LEGEND AND NOTES FIGURES 4 and 5- SWELL -CONSOLIDATION TEST RESULTS TABLE I- SUMMARY OF LABORATORY TEST RESULTS PURPOSE AND SCOPE OF STUDY This report presents the results of a subsoil study for a proposed residence to be located at 0074 County Road 225, Garfield County, Colorado. The project site is shown on Figure 1. The purpose of the study was to develop recommendations for the foundation design. The study was conducted in accordance with our proposal for geotechnical engineering services to Terry and Tori Davis dated February 9, 2009. A field exploration program consisting of exploratory borings was conducted to obtain information on the subsurface conditions. Samples of the subsoils obtained during the field exploration were tested in the laboratory to detennine their classification, compressibility or swell and other engineering characteristics. The results of the field exploration and laboratory testing were analyzed to develop recommendations for foundation types, depths and allowable pressures for the proposed building foundation. This report summarizes the data obtained during this study and presents our conclusions, design recommendations and other geotechnical engineering considerations based on the proposed construction and the subsurface conditions encountered. PROPOSED CONSTRUCTION Building plans for the residence are being developed. We understand the proposed residence will be one story wood frame or timber frame construction above a crawlspace or slab -on -grade floor. A detached garage will be located adjacent to the residence. Grading for the structure is assumed to be relatively minor with cut depths between about 2 to 4 feet. We assume relatively light foundation loadings, typical of the proposed type of construction. If building loadings, location or grading plans change significantly from those described above, we should be notified to re-evaluate the recommendations contained in this report. Job No. 109 039A G ech -2 - SITE CONDITIONS The property is an undeveloped 40 acre parcel located on the east side of County Road 225 and north of State Highway 6. The building area has been cleared of vegetation. The surrounding area is vegetated with grass, weeds, sage brush and cottonwood trees. The ground surface is relatively flat with a slight slope down to the south. A large irrigation ditch crosses the property from west to east and the building area is located uphill and north of the ditch. FIELD EXPLORATION The field exploration for the project was conducted on February 26, 2009. Two exploratory borings were drilled at the locations shown on Figure 1 to evaluate the subsurface conditions. The borings were advanced with 4 inch diameter continuous flight augers powered by a truck -mounted CME -45B drill rig, The borings were logged by a representative of Hepworth-Pawlak Geotechnical, Inc. Samples ofthe subsoils were taken with a 2 inch I.D. spoon sampler. The sampler was driven into the subsoils at various depths with blows from a 140 pound hammer falling 30 inches. This test is similar to the standard penetration test described by ASTM Method D-1586. The penetration resistance values are an indication of the relative density or consistency of the subsoils. Depths at which the samples were taken and the penetration resistance values are shown on the Logs of Exploratory Borings, Figure 2. The samples were returned to our laboratory for review by the project engineer and testing. SUBSURFACE CONDITIONS Graphic logs of the subsurface conditions encountered at the site are shown on Figure 2, The subsoils consist of about 6 inches of topsoil root zone overlying and silty sand and sandy silt down to the maximum depth explored of 23 feet. Job No. 109 039A G8 tech -3 - Laboratory testing performed on samples obtained from the borings included natural moisture content, density and percent finer than sand size gradation analyses. Results of swell -consolidation testing performed on relatively undisturbed drive samples, presented on Figures 4 and 5, indicate low to moderate compressibility under conditions of loading and wetting. The laboratory testing is summarized in Table 1. No free water was encountered in the borings at the time of drilling or when checked 6 days later and the subsoils were slightly moist to moist. DESIGN RECOMMENDATIONS FOUNDATION S Considering the subsurface conditions encountered in the exploratory borings and the nature of the proposed construction, we recommend the building be founded with spread footings bearing on the natural soils. The design and construction criteria presented below should be observed for a spread footing foundation system. 1) Footings placed on the undisturbed natural granular soils should be designed for an allowable bearing pressure of 1,500 psf Based on experience, we expect settlement of footings designed and constructed as discussed in this section will be about 1 inch or less. Additional settlements on the order of 1 to 2 inches could occur if the soils become wet. 2) The footings should have a minimum width of 18 inches for continuous walls and 2 feet for isolated pads. 3) Exterior footings and footings beneath unheated areas should be provided with adequate soil cover above their bearing elevation for frost protection. Placement of foundations at least 36 inches below exterior grade is typically used in this area. Job No. 109 039A Gtech -4- 4) Continuous foundation walls should be reinforced top and bottom to span local anomalies such as by assuming an unsupported length of at least 10 feet. Foundation walls acting as retaining structures should also be designed to resist a lateral earth pressure corresponding to an equivalent fluid unit weight of at least 55 pcf 5) All topsoil and any loose or disturbed soils should be removed and the footing bearing level extended down to the relatively dense natural soils. The exposed soils in footing area should then be moistened and compacted. If water seepage is encountered, the footing areas should be dewatered before concrete placement. 6) A representative of the geotechnical engineer should observe all footing excavations prior to concrete placement to evaluate bearing conditions, FLOOR SLABS The natural on-site soils, exclusive of topsoil, are suitable to support lightly loaded slab - on -grade construction. To reduce the effects of some differential movement, floor slabs should be separated from all bearing walls and columns with expansion joints which allow unrestrained vertical movement. Floor slab control joints should be used to reduce damage due to shrinkage cracking. The requirements for joint spacing and slab reinforcement should be established by the designer based on experience and the intended slab use. A minimum 4 inch layer of free -draining gravel should be placed beneath slabs. This material should consist of minus 2 inch aggregate with at least 50% retained on the No. 4 sieve and less than 2% passing the No. 200 sieve, All fill materials for support of floor slabs should be compacted to at least 95% of maximum standard Proctor density at a moisture content near optimum. Required fill can consist of the on-site soils devoid of vegetation, topsoil and oversized rock. Job No. 109 039A GecPtech 5 UNDERDRAIN SYSTEM Although free water was not encountered during our exploration, it has been our experience in the area that local perched groundwater can develop during times of heavy precipitation or seasonal runoff Frozen ground during spring runoff can create a perched condition. We recommend below -grade construction, such as retaining walls and crawlspace areas, be protected from wetting and hydrostatic pressure buildup by an underdrain system. Shallow crawlspace (less than 4 feet) and slab -on -grade construction should not require an underdrain system provided positive drainage is provided foundation wall backfill is well -compacted and slopes away from the foundation. If installed, the drains should consist of drainpipe placed in the bottom of the wall backfill surrounded above the invert level with free -draining granular material. The drain should be placed at each level of excavation and at least 1 foot below lowest adjacent finish grade and sloped at a minimum I% to a suitable gravity outlet. Free -draining granular material used in the underdrain system should contain less than 2% passing the No. 200 sieve, less than 50% passing the No. 4 sieve and have a maximum size of 2 inches. The drain gravel backfill should be at least 1 1/2 feet deep. SURFACE DRAINAGE The following drainage precautions should be observed during construction and maintained at all times after the residence has been completed: I) Inundation ofthe foundation excavations and underslab areas should be avoided during construction. 2) Exterior backfill should be adjusted to near optimum moisture and compacted to at least 95% of the maximum standard Proctor density in pavement and slab areas and to at least 90% of the maximum standard Proctor density in landscape areas. 3) The ground surface surrounding the exterior ofthe building should be sloped to drain away from the foundation in all directions. We Job No. 109 039A G legtech -6 - recommend a minimum slope of 6 inches in the first 10 feet in unpaved areas and a minimum slope of 3 inches in the first 10 feet in paved areas. Free -draining wall backfill should be capped with about 2 feet of the on- site soils to reduce surface water infiltration. 4) Roof downspouts and drains should discharge well beyond the limits of all backfill. 5) Landscaping which requires regular heavy irrigation should be located at least 10 feet from foundation walls. Consideration should be given to use of xeriscape to reduce the potential for wetting of soils below the building caused by irrigation. LIMITATIONS This study has been conducted in accordance with generally accepted geotechnical engineering principles and practices in this area at this time. We make no warranty either express or implied. The conclusions and recommendations submitted in this report are based upon the data obtained from the exploratory borings drilled at the locations indicated on Figure 1, the proposed type of construction and our experience in the area. Our services do not include determining the presence, prevention or possibility of mold or other biological contaminants (MOBC) developing in the fixture. If the client is concerned about MOBC, then a professional in this special field of practice should be consulted. Our findings include interpolation and extrapolation of the subsurface conditions identified at the exploratory borings and variations in the subsurface conditions may not become evident until excavation is performed. If conditions encountered during construction appear different from those described in this report, we should be notified so that re-evaluation of the recommendations may be made. This report has been prepared for the exclusive use by our client for design purposes. We are not responsible for technical interpretations by others of our information. As the project evolves, we should provide continued consultation and field services during construction to review and monitor the implementation of our recommendations, and to Job No, 109 039A G1.-Stech -7_ verify that the recommendations have been appropriately interpreted. Significant design changes may require additional analysis or modifications to the recommendations presented herein. We recommend on-site observation of excavations and foundation bearing strata and testing of structural fill by a representative of the geotechnical engineer. Respectfully Submitted, HEPWORTH - PAWLAK GEOTECHNICAL, INC. Louis E. Eller Reviewed by: Daniel E. Hardin, P.E. 5� 2414 6� z LEEllcsw'� cc: Lindauer Dunn Inc. : G. Job No. 109 039A w 0 2 w LL w BORING 2 el BUILDING AREA BORING 1 80' EXISTING DRIVE 80' COUNTY ROAD 225 NOT TO SCALE PASTURE 109 039A Hepworth—Powick Geotechnical LOCATION OF EXPLORATORY BORINGS Figure 1 Depth Feet 0 5 - 10 1•...1.11 15 - 20 BORING 1 BORING 2 / 7112 / WC= - 23/126.0 WC=4.2 f DD=110 DD=103 / -200=30 / // 6/12 /f ✓ - 4/12 /- WC=6.7 WC=7.4 / DD=96 DD=93 / / -200=59 / // - 12/12 / 8/12 / /12112 /WC=14.0 11/12 DD=113 / 71 15/12 WC= 16.8 DD=110 10 15 20 25 25 Note: Explanation of symbols is shown on Figure 3. a) s a) 0 109 039A 1-I Hepworth—Powlak Geotechnical LOGS OF EXPLORATORY BORINGS Figure 2 LEGEND: 7 7/12 TOPSOIL; organic sandy clay and silt, firm, slightly moist, brown. The site had been grubbed. This is the remaining root zone. SILT (ML); sandy to very sandy, medium stiff to stiff, loose to medium dense, slightly moist to moist with depth, reddish brown, upper 4 feet appears to be silty sand. Relatively undisturbed drive sample; 2 -inch I.D. California liner sample. Drive sample blow count; indicates that 7 blows of a 140 pound hammer falling 30 inches were required to drive the California sampler 12 inches. NOTES: 1. Exploratory borings were drilled on February 26, 2009 with 4 -inch diameter continuous flight power auger. 2. Locations of exploratory borings were measured approximately by pacing from features shown on the site plan provided. 3. Elevations of exploratory borings were not measured and the logs of exploratory borings are drawn to depth. Boring 1 is about 1Y feet higher than Boring 2. 4. The exploratory boring locations and elevations should be considered accurate only to the degree implied by the method used. 5. The lines between materials shown on the exploratory boring logs represent the approximate boundaries between material types and transitions may be gradual. 6. No freewater was encountered in the borings at the time of drilling or when checked 6 days later. Fluctuation in water level may occur with time. 7. Laboratory Testing Results: WC = Water Content (%) DD = Dry Density (pct) -200 = Percent passing No. 200 sieve 109 039A LEGEND AND NOTES Figure 3 Compression Compression 0 1 2 3 4 0 1 2 3 Moisture Content = 4.2 percent Dry Density = 103 pcf Sample of: Silty Sand From: Boring 1 at 3 Feet Compression upon wetting 0.1 1.0 10 APPLIED PRESSURE - ksf 100 Moisture Content = 7.4 percent Dry Density = 93 pcf Sample of: Sandy Silt From: Boring 1 at 8 Feet Compression upon wetting r 0.1 1.0 10 APPLIED PRESSURE - ksf 100 1 109 039A H Hepworth—Pcwiak Geotechnical SWELL -CONSOLIDATION TEST RESULTS Figure 4 Compression % Compression % 0 1 2 3 0 1 2 3 Moisture Content = 6.0 Dry Density = 110 Sample of: Silt and Sand From: Boring 2 at 2 Feet percent pcf emenommini No movement upon wetting 0 0.1 1.0 10 APPLIED PRESSURE - ksf 100 Moisture Content = 6.7 percent Dry Density = 96 pcf Sample of: Sandy Silt From: Boring 2 at 7 Feet No movement upon wetting 0.1 1.0 10 APPLIED PRESSURE - ksf 100 109 039A 1-4 Hepworth—Pawiak Geotechnical SWELL -CONSOLIDATION TEST RESULTS Figure 5 HEPWORTH-PAWLAK GEOTECHNICAL, INC. TABLE 1 SUMMARY OF LABORATORY TEST RESULTS Job No. 109 039A SAMPLE LOCATION NATURAL MOISTURE CONTENT c%) NATURAL DRY DENSITY (Pd) GRADATION PERCENT PASSING NO. 200 SIEVE _ ATTERBERG LIMITS UNCbNFINED COMPRESSIVE STRENGTH (PSF) SOIL OR BEDROCK TYPE BORING DEPTH (ftZ GRAVEL (%) SAND (%) LIQUID LIMIT (%) PLASTIC INDEX (%) 1 3 4.2 103 30 Silty Sand 8 7.4 93 59 Sandy Silt 2 2 6.0 110 Silt and Sand 7 6.7 96 Sandy Silt 17 14.0 113 Sandy Silt 22 16.8 110 Sandy Silt Parcel Detail Pagel of4 Garfield County Assessor/Trey surer Parcel Detail Information Assessor/Treasures Property Search 1 Assessor Subset Query 1 Assessor Sales Search Clerk & Recorder Reception Search Basic Building Characteristics 1 Tax Information Parcel Detail 1 Value Detail 1 Sales Detail 1 Residential/Commercial Improvement Detail Land Detail 1 Photographs I Mill Levy Revenues Detail Tax Area 021 Account Number R210444 Parcel Number 217906400071 2008 Mill Levy 47.116 Owner Name and Mailing Address DAVIS, TERRY D & VICTORIA A 0074 COUNTY ROAD 225 RIFLE, CO 81650 Assessor's Parcel Description (Not to be used as a legal description) [SECT,TWN,RNG:6-6-92 DESC: SWSE BK:0506 PG:0239 BK:0436 PG:0432 BK:1667 PG:595 RECPT:669587 BK:0794 PG:0181 BK:0794 PG:0180 BK:0702 PG:0680 BK:0693 PG:0811 BK:0680 PG:0718 Location Physical Address: Subdivision: Land Acres: 74 225 COUNTY RD RIFLE 40 http://www.garcoact.com/assessor/pa rcel.asp?Parcel Nu m ber=217906400071 11/24/2009 Parcel Detail Page 2 of4 Land Sq Ft: Section 0 Township Range 6 6 92 2009 Property Tax Valuation Information Additional Value Detail Most Recent Saie Sale Date: Sale Price: 3/2/2005 669,000 Additional Safes Detail Basic Building Characteristics Num ber of Residential Buildings: Number ofComm/1nd Buildings: 1 0 I 1 Actual Value Assessed Value Land: 10,570 3,070 Improvements: 97,870 8,340 Total: 108,440 11,410 Additional Value Detail Most Recent Saie Sale Date: Sale Price: 3/2/2005 669,000 Additional Safes Detail Basic Building Characteristics Num ber of Residential Buildings: Number ofComm/1nd Buildings: 1 0 I 1 Residential Building Occurrence 1 Characteristics l 1 STORY: 1,023 PORCH, ENCLOSED, FINISHED: 84 TOTAL HEATED AREA 1,023 ABSTRACT CODE: FARM/RANCH RESIDENCE - IMPS ARCHITECTURAL STYLE: 1-5TORY EXTERIOR WALL: BOARD/BATT ROOF COVER: [COMP SHNGL I http://www, ga rcoact.com/assessor/parcef.asp? Pa rcel Num ber=217906400071 11/24/2009 Parcel Detail Page 3 0f 4 ROOF STRUCTURE: 1[GABLE INTERIOR WALL: FLOOR: FLOOR: HEATING FUEL: HEATING TYPE: STORIES: BATHS: ROOMS: UNITS: BEDROOMS: YEAR BUILT: DRYWALL SHT VINYL CARPET GAS FORCED AIR STORIES 1.0 1 4 1 2 1909 Additional Residential/Commercial Improvement Detail Tax information Tax Year Transaction Type Amount 2008 Tax Payment: Second Half ($245.70) 2008 Tax Payment: First Half ($245.70) 2008 Tax Amount $491.40 2007 Tax Payment: Second Half ($152.30) 2007 Tax Payment: First Half ($152.30) 2007 Tax Amount $304.60 2006 Tax Payment: Second Half. ($150.10) 2006 Tax Payment: First Half ($150.10) 2006 Tax Amount $300.20 2005 Tax Payment: Second Half ($150.69) 2005 Tax Payment: First Half ($150.69) 2005 Tax Amount $301.38 2004 Tax Payment: Whole ($337.22) 2004- Tax Amount $337,22 2003 Tax Payment: Whole ($374.00) 2003 Tax Amount $374.00 I 11 11 1 http : //www. g a rcoa ct. co m /assessor/parcel .asp ? Pa rce l N u m be r=217906400071 11/24/2009 Parcel Detail Page 4 oE4 1 2002 Tax Payment: Whole 11 ($354.44)1 2002 2001 2001 2000 2000 1999 1999 Tax Amount Tax Payment: Whole Tax Amount Tax Payment: Whole Tax Amount Tax Payment: Whole Tax Amount Mill Lever Revenues Detail $354.44 ($362.06) $362,06 ($372,06) $372.06 ($373.04) $373.04 T p //Page Assessor Database Search Options 1 Treasurer Database Search Options Clerk & Recorder Database Search Options Garfield County Home Page The Garfield County Assessor and Treasurer's OFfices make every effort to collect and maintain accurate data. However, Good Turns Software and the Garfield County Assessor and Treasurer's Offices are unable to warrant any of the information herein contained. Copyright ® 2005 - 2008 Good Turns Software. All Rights Reserved. Database & Web Design by Good Turns Software. http://www.garcoact.com/assessor/parcd. sp?ParcelNumber=217906400071 11/24/2009 Permit Card Garfield County Building and Planning Department 108 8th Street, Suite 401 Glenwood Springs, CO 81601 Phone: (970)945-8212 Fax_ (970)384-3470 POST ON SITE Permit NO BLRE"11-09-1378 up) *d tial � 41c ing g Issue Date: 4/14/2010 Expires: 10/11/2010 AGREEMENT In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structured for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building department and IMMEDIATELY BECOME NULL AND VOID. Residential Building Parcel #:217906400071 Owner's Name: Terry Davis Job Address; 0360 CR 225 RIFLE, CO Owner's Phone: 970-625-9160 Total Square Feet: 6424 Contractor(s) Phone Primary Contractor Work Description: Single family dwelling with attached garage and covered/uncovered decks. Inspection Scheduling Code itipectio-n ' d 3u IM17 .,', C ' meets:. . ...., .. ... . .. :.. , f a.Ci.i ,,._.D f ...- Footers ! e/,:e f -v Foundation Walls 9 r _ f=raming Ok —63 ,N\A-1A44 f Drywall g '5 f l Final n', 1Z0Q7/ Misc t35 Insulation BQ ��74:, Grout N . Mechanical LIG Plumbing ,05 L. L %cir p 727l3 7rA f 6 "Zi Rough Plumbing 1 3 I � Gas ,��—. �/ 0 § ' , `w, + + 2 L'// 4ario-( lures i� .,//to 7" P t2 ADDITIONAL INSPECTIONS MAY BE REQUIRED POST THIS IN CONSPICUOUS PLACE WHEN CONSTRUCTION IS STARTED For Inspections Call: 1-888-868-5306 7 ,'. A 4-:5-407/,/ z?7, //-2_9-/P k CI C VM- ill ij 0 7-23- )0 oglA _<-;t` d���- T-74AL 9i1 zi40 G �i Project Address Garfield County Building & Planning Department 108 Bth Street Suite 401 Glenwood Springs, CO 81601 - Phone: (970)945-8212 Fax: (970)384-3470 Parcel No. Subdivision issue Date: 4/1412010 Section Expires: 04/14/2011 Township Range 0360 CR 225 RIFLE, CO Owner Information 217906400071 Address Phone 6 6 Cell 92 Terry Davis 074 CR 225 Rifle CO 81650 970-625-9160 Contractor(s) Phone Primary Contractor Colonna Construction (970)625-3376 Yes Proposed Construction 1 Details Septic tank for single family dwelling. FEES DUE Fee Percolation Test Septic Fee - New Total: Amount $100.00 $73.00 $173.00 Valuation: Total Sq Feet: FEES PAID $ 0.00 0 Inv Total Paytype Amt Paid Amt Due Inv # SEPT -11-09-19905 $ 173.00 Check # 1505 Check # 1507 $100.00 $73.00 $ 0.00 Required Inspections: For Inspections call : 1(970)384-5003 Inspection IVR Building Department Copy Wednesday, April 14, 2010 2 GARI IELD COUNTY SEPTIC PERMIT APPLICATION 108 8th Street, Suite 401, Glenwood Springs, Co 81601 Phone: 970-945-8212 / Fax: 970-384-3470 / Inspection Line: 970-384-5003 WWW. garf field -county com 1 Parcel No: (this information is available at the assessors office 970-945.9134) 2-17906,100071 2 Building Permit #: 378 ' Job Ad ress: (if an address has not been assigned, please provide Cr, limi or Street Name & City) or and legal description -7`1 eea L2 s- '/4 I GO . 3 Issue Date: { -t- IL1--D0 I.CTh Lot Size: Lot No: Block No: Subd,l Exemption: 40 f -G 4 .7/Ib APPROVAL `Owner: (property owner) i e,44.1 1)14 ''a Mailing Address -- Z779 1 eo. Sik5�' t Ph: 6na = 9/470 Alt Ph: 5 Contractor. 6fac 4.4t.411- ['e..1-64. eve Maas�' ing Address A; .50de /964> An, 6 Ph: 6'2r— 53/4, Alt Ph: ,/,q -g7o , 6 Engineer: Mailing Address Ph: Ati Ph: 7 PERMIT REQUEST FOR: (['` New Installation ( ) Alteration ( ) Repair 8 WASTE TYPE: (,welling ( )Transient Use ( }Commercial or industrial ( )Non- Domestic wastes ( )Other - Describe 9 BUILDING OR SERVICE TYPE: /✓ / r7ettif,' L(f %/Ont Number 6f bedrooms ! Q Garbage Grinder (Wes ( )No i 0 SOURCE & TYPE OF WATER SUPPLY: ( )WELL ('SPRING ( )STREAM OR CREEK ( )CISTERN If supplied by COMMUNITY WATER, give name of supplier: 11 DISTANCE TO NEAREST COMMUNITY SEWER SYSTEM: Was an effort made to connect to the Community System? q pm t f -s .t/G' YOUR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT WILL NOT BE ISSUED WITH OUT A SITE PLAN 12 GROUND CONDITIONS: De, ii 6D u:7' AX (4.341-6-4- O4tDepth to 151 Ground Water Table Percent Ground Slope Depth 13 TYPE OF INDIVIDUAL SEWAGE DISPOSAL SYSTEM (ISDS) PROPOSED: (i4Septic Tank ( )Aeration Plant ( )Vault ( )Vault Privy ( )Composting Toilet ( )Recycling, Potable Use ( )Recycling, other use ( )Pit Privy ( )Incineration Toilet ( )Chemical Toilet ( )Other- Describe 14 FINAL DISPOSAL BY: (t4Absorption trench, Bed or Pit ( )Underground ( )Wastewater pond ( )Other- Dispersal ( )Above Ground Dispersal ( }Evapotranspiration ( )Sand filter Describe 15 Will effluent be discharged directly Into waters of the state? ( )YES (I.)NO 16 PERCOLATION TEST RESULT: (to be completed by Registered Professional Engineer, ii the Engineer does the Percolation Test) Minutes per inch in hole No.1 Minutes per inch in hole No.3 No, Minutes per inch in hole No,2 Minutes per inch in hole Name, address & telephone of RPE who made soil Name, address & telephone of RPE responsible absorption test: for design of the system: 17 Applicant acknowledges that the completeness of the application is conditional upon such further mandatory and additional test and reports as may be required by the local health department to be made and furnished by the applicant or by the local health department for purposed of the evaluation of the application; and the issuance of the permit is subject to such terms and conditions as deemed necessary to insure compliance with rules and regulations made, information and reports submitted herewith and required to be submitted by the applicant are or will be represented to be true and correct to the best of my knowledge and belief and are designed to be relied on by the local department of health in evaluating the same for purposes of issuing the permit applied for herein. I further understand that any falsification or misrepresentation may result in the denial of the application or revocation of any permit granted based upon said application an�egel-actt'sn for perju as ed bylaw. tAv1 01 -de- O j OWNERS 5 ATURE DATE STAFF USE ONLY Permit Fee: i .13 i. Perk Fee: 11■a . I.OT ,d5=it Total fees: L 1 3 Building Permit #: 378 Septic Permit #: —1319. Issue Date: { -t- IL1--D0 I.CTh Sul ing & Plannig Dept:. .7/Ib APPROVAL DATE