Loading...
HomeMy WebLinkAboutApplication - PermitGarfield County No. I lObSO I Building & Sanitation Department 108 8th Street, Suite #401 Glenwood Springs, Co. 81601 Office 945-8212 Inspection Line 384-5003 Job Address: 1222 cr 238, Silt Locality: 2125-332-00-190 ------------------------------------------------- Use of Building: garage Owner: Smith, Leroy Contractor: R.T. Taylor ------------------------~--------------------- Amount of Permit: $322.16 ----'------Date: 0-tQ-o~ Clerk: :\tQ~ (U • GARFIELD COUNTY BUILDING PERMIT APPLICATION 108 a·• Street, SUite 401, OleDwoocl S prlDp, CO 81601 PhoDel 970.945·8:3 1:3 I Fax: 970.384-3470 1 IDapeotlon Line: 970.384-5003 PennitNo: ________________ __ Job Address: r-:--.J....,---:-:-----' ')... 'J-)- Lot No : Lo-\ g._ C..,(L do.~ Block No : ). 3 5 Sq. Ft. of Lot: ~.$" 6 7 8 Class of Work: 0 9 Garage: 10 0 II Valuation of Work: 12 Special Conditions: NOTICE A SEPARATE ELECTRICAL PERMIT IS REQUIRED AND MUST Bit I SSUED BY THE STATE OF COLORADO. THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTI ON AUTHORIZED IS NOT COMMENCED WITHLN 180 DAYS, OR, IF' CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY T IME AFTER WORK I S <.:OMMJ::N(;t:D. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS GOVERNING THIS TYPE OF WORK WILL BE COMPLETED WITHIN WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AllfHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTI ON OR THE PERFORMANCE OF CONSTRUCTION. Parcel/Schedule No:.._. ~~)-5" J"J;L ~ Si 1+ I co olto~ ___ ______, Wk Ph: Lie. No. Ph: Lie. No . lv ) Height: I <.. ' No . of Floors: 0 Alteration o Remove Addition 0 Move Carport: 0 Single 0 Double Site Plan Adjusted Valuations: Plan Check Fee: /2-l:, 4 I Permit Fee: Total Fee: I 3 2?-LL Dated Permit Issued: OCC Group : uc Const. Type: Zoning: Setbacks: Manu . Home: ISDS No . & Fee: AGREEMENT PERMISSION IS HEREBY GRANTED TO THE APPLICANT AS OWNER, CONTRACTOR AND/OR THE AGENT OF THE CONTRACTOR OR OWNER TO CONSTRUCT THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTM~;NT. IN CONSIDERATION OF THE ISSSUANCE OF THIS PERMIT, THE SIGN ER. HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND USE REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN LN 30.28.201 CRS AS AMENDED. THE SIGNER FURTHER AGREES THAT IP THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPILED WITH IN THE LCOATION, ERECTION, CONSTRUCTION, AND USE OF THE ABOW DESCRIBED STRUCTURE, THE PERMIT MAY BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT SHALL BECOME NULL AND VOID. 'THE ISSUANCE OF A PERMT BASED UPON PLANS, SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT 'THE BUILDING OFFICIAL FROM T H EREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING BUILDING OPERATION BEING CARRIED ON 'THER EUNDE R WHEN I N VIOLATION OFTHS CODE OR ANY OTHER ORDINANCE OR REGULATION OF THIS JURISDICTION. THE REVIEW OF SUBMITTED PLANS AND SPECIFICATIONS AND I NSPECTIONS CONDUCTED T H EREAFTER DOES NOT CONSTI'fUTE AN ACCEPTANCE OF ANY RESPONSIBIUTI ES OR LIABLITIES BY GARFIELD COUNTY FOR ERRORS, OMISSIONS OR DISCREPENCIES. 'THE RESPONSI BILrrY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICIALLY WrfH THE ARTICTECT, DESIGNER, BUILDER, AND OWNER. COMMENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS LNTEREST. !/~ I H EREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE AGREEMENT ABOW (INITIAqY __ -:;z_,.L'---- Bt>-0-\Q-D 1- c~ lb4li Jttq:s .2<:) The following items are required by Garfield County for a final inspection: 1. A final Electrical Inspection from the Colorado State Electrical Inspector; 2. Permanent address assigned by Garfield County Building Department posted where readily visible from access road; 3. A fin ished roof, a lockable house, complete exterior siding, exterior doors and windows installed, a complete kitchen with cabinets, a sink w ith hot & cold running water, non-absorbent kitchen floor coverings, counter tops and finished walls, ready for stove and refrigerator, all necessary plumbing; 4. All bathrooms must be complete, with washbowl, tub or shower, toilet stool, hot and cold running water, non-absorbent floors and walls finished and a privacy door; 5. All steps outside or inside over three (3) steps must have handrails, guard rails on balconies or decks over 30" high constructed to all me and IRC requirements ; 6. Outside grading done to where water will detour away from the building; 7. Exceptions to the outside steps, decks and grading may be made upon the demonstration of extenuating circumstances, i.e. weather, but a Certificate of Occupancy will not be issued until all the required items are completed and a final inspection made; 8 . A final inspection sign off by the Garfield County Road & Bridge Department for drive way installation, where applicable; as well as any final sign off by the Fire District, and/or State Agencies where applicable . 9 . If you will be connecting to a public water and/or sewer system, proof of the tap fees have been paid and the connections inspected by the service provider prior to issuance of a C.O. A CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. ****A CERTIFICATE OF OCCUPANCY MAY TAKE UP TO 5 BUSINESS DAYS TO BE PROCESSED AND ISSUED. ****CANNOT OCCUPY OR USE DWELLING UNTIL A CERTIFICATE OF OCCUPANCY (C.O.) IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. I understand and agree to abide by the above conditions for occupancy, use and the issuance of a Certificate of Occupancy for the dwelling under building permit # ____ _ Signature Bpapplicationoctober2006 Date I I ' VALUATION/FEE DETERMINATION Applica nt. __ <""""-L&=I.;....;;'.....J\L....;·~~---­ Address __ -::-\L-7...__.'2.._-7..__ ...... < .... a..___'2'---.3"'""8-,J.._ Da t e ____ C...~...t ~;;..\J...::0:::....-.....:0:.:::..0...~....-___ _ Finished (Li vable Area): Main Upper Lower Other Basement: Total Square Feet Valu ation U nfi nished Conversion of Unfini shed to Finished Plan Check Fee for Conversion Valu ation Gar a£e: 5 7£." \.~-: Val uat io n Crawl Space: Val uation Decks/Pati os: Covered Val uation Open Valuation Total Val uation /0 36 ~ S ubdi vis ion Lot/Block C ontract o r 2-e ~~--"-'\ E~·Ht> h. La~ 7.. /Z-'l T"'r GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS For SINGLE F AMlL Y DWELLING CONSTRUCTION Including NEW CONSTRUCTION ADDITIONS ALTERATIONS And MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. When reviewing a plan and it's discovered that required information has not been provided by the applicant, this will result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor shall be required to provide this information before the plan review can proceed. Other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. Any project with more than ten (10) occupants requires the plans to be sealed by a Colorado Registered Design Professional. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following checklist prior to and during design. Applicants are required to indicate appropriately and to submit the completed checklist at time of application for a permit. Plans to be included for a Building Permit, most be on drafting paper at least 18"x24" and drawn to scale. Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with I decks, balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line and original grade. A section showing in detail, from the bottom of the footing to the top of the roof, including re-bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house-rap, (which is required), siding or any approved building material. Engineered foundations may be required. A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. wind speed, wind exposure B or C, and a 36 inch frost depth. All sheets to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be incompliance with the 2003 IRC. I. Is a site plan included that identifies the location of the proposed structure or addition and distances to the property lines from each comer of the proposed structure( s) prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Properties with slopes of30% or greater must be shown on the site plan. (NOTE Section: 106.2) Any site plan for the placement of any portion of a structure within 50 ft. of a property line and not within a previously surveyed building envelope on a subdivision final plat shall be prepared by a licensed surveyor and have the surveyor's signature and professional stamp on the drawing. Any structure to be built within a building envelope of a lot shown on a recorded subdivision plat shall include a copy of the building envelope as it is shown on the final plat with the proposed structure located within the envelope. Yes .r 2. Does the site plan also include any other buildings on the property, setback easements and utility easements? Please refer to Section 5.05.03 in the Garfield County Zoning Resolution if the property you are applying for a building permit on is located on a comer lot. Special setbacks do apply. Yes / 3. Does the site plan include when applicable the location of the I.S.D.S. (Individual Sewage Disposal System) and the distances to the property lines, wells (on subject property and adjacent properties), streams or water courses? Yes ./ 4. Does the site plan indicate the location and direction of the County or private road accessing the property? 2 Yes ____ _ 5. Are you aware that prior to submittal of a building permit application you are required to show proof of a driveway access permit or obtain a statement from the Garfield County Road & Bridge Department stating one is not necessary? You can contact the Road & Bridge Department at 625-860 I. Yes v f:.'j.U>f\ 6. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the IRC or per stamped engineered design? Yes 7 7. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and earth? Yes }Jl p,. 8. Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces a~soffits? Yes , _____ _ 9. Do the plans include design loads as required by Garfield County for roof snow loads, (a minimum of 40 pounds per square foot up to & including 7,000 feet above sea level), floor loads and wind loads? Yes ,_.; I 0. Does the plan include a building section drawing indicating foundation, wall, floor, and roof construction? Yes v" II. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or joists or trusses? Yes ./ I2. Does the building section drawing or other detail include the method of positive connection of all columns and beams? Yes / 13. Does the elevation plan indicate the height of the building or proposed addition from the undisturbed grade to the midpoint between the ridge and eave of a gable or shed roof or the top of a flat roof? (Building height measurement usually not to exceed 25 feet) Yes .., 14. Does the plan include any stove or zero clearance fireplace planned for installation including 3 15. 16. 17. 18. 19. 20. 21. 22. 23. make and model and Colorado Phase II certifications or phase II EPA certification? Yes No / Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the IRC? / Yes No ____________ __ Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basemc;,llts comply with the requirements of the IRC? Yes No ____________ _ Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable rooms? Yes No / ------ Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety glazing for these areas? Yes No / ------ Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? / Yes No ____________ _ Do you understand that if you are building on a parcel of land created by the exemption process or the subdivision process, are building plans in compliance with all plat notes and/or covenants? Yes No ______ __ Do you understand that if you belong to a Homeowners Association (HOA), it is your responsibility to obtain written permission from the association, if required by that association, prior to submitting an application for a building permit? The building permit application will be accepted without it, but you run the risk of the HOA bringing action to enforce the covenants, which can result in revocation of permit issued. Additionally, your Plan Review fee is not refundable if the plans have been reviewed by the Building Department prior to any action by the HOA that requires either revocation or substantial modification of the plans. Yes No " ------ Will this be the only residential structure on the parcel? Yes / No Ifno-Explain: ____________ _ Have two (2) complete sets of construction drawings been submitted with the application? Yes / 4 24. Do you understand that the minimum dimension a home can be on a lot is 20ft. wide and 20ft. long? / Yes No ----- 25. Have you designed or had this plan designed while considering building and other construction cod7requirements? Yes -No ------ 26. Do your plans comply with all zoning rules and regulations in the County related to your properties zone district? Yes / No ------- 27. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by the Garfield County Building Department? Yes / No ------ 28. Do you understand that approval for design and/or construction changes are required prior to the application of these changes? Yes / No ------ 29. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application submittal and that you will be required to pay the "Permit Fee" as well as any "Road Impact" or "Septic System" fees required, at the time you pick up your building ""mit? Yes No ------ 30. Are you aware that you must call in for an inspection by 3:30 the business day before the requested inspection in order to receive it the following business day? Inspections will be made from 7:30a.m. to 3:30p.m. Monday through Friday. Inspections are to be called in Jo 384-5003. Yes ~ No ______ _ 31. Are you aware that requesting inspections on work that is not ready or not accessible will result in a $50 .00 re-inspection fee? Yes / No ____ _ 32. Are you aware that you are required to call for all inspections required under the IRC including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of the building? Yes / No ------- 5 33. Are you aware that the Pennit Application must be signed by the Owner or a written authority being given for an Agent and that the party responsible for the project must comply with the IRC/? Yes No ___________ _ 34. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups, unless you as the homeowner are performing the work? The license number of the person performing the work will be required at time 9f applicable inspection. Yes / No __________ __ 35. Are you aware, that on the front of the Building Permit Application you will need to fill in the Parcel/Schedule Number for the lot you are applying for this permit on prior to submittal of a building permit application? Your attention in this is appreciated. Yes / No _______ _ 36. Do you know that the local fire district may require you to submit plans for their review of fire safety issues? Yes / No (please check with the building department about this requirement) 37 . Do you understand that if you are plann ing on doing any excavating or grading to the property prior to issuance of a building pem1it that you will be required to obtain a grading permit? / Yes ___ _ 38 . Are you aware that if you will be connecting to a public water and/or sewer system, that the tap fees have to be paid and the connections inspected by the service provider prior to the issuance of a Certificate of Occupancy? Yes / I hereby acknowledge that I have read, understand and answered these questions to the best of my a ility. Date 1 I Phone:. ___________ (days); (evenings) Project Name: ____ -'L.....,P,.__.~_:.e_-==5:..___::t11l~l__,_~--------~---- /_ . I \_ d-/A /? ~ _j C-<;;-'7 c7f-Project Address:. _________ '-~--'-ol-_A ____ <.__.e~ ___ <-_____ C) __________________ _ Notes: If you have answered "No" on any of the questions, you may be required to provide this 6 information at the request of the Building Official prior to beginning the plan review process. Delays in issuing the permit are to be expected. Work may not proceed without the issuance of a permit. I fit is determined by the Building Official that additional information is necessary to review the application and plans to determine minimum compliance with the adopted codes, the application may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review, delay in issuance of the permit or delay in proceeding with construction. Bpminreq November2006 7 PLAN REVIEW CHECKLIST Applicant S V\A , fu Date q -\ (J ~ O\ Building ~ngineered Foundation ~Driveway Permit fX \ .-::, ~1 --.1LSurveyed Site Plan ~'L c;-o ' 4-Septic Permit and Setbacks ~ Gradeffopography 30% ~Attach Residential Plan Review List L~um Application · Questionnaire Lsubdivision Plat Notes ~Fire Department Review ~Valuation Determination/Fees ~ed Line Plans/Stamps/Sticker ~Attach Conditions ~Application Signed J Plan Reviewer To Sign Application .dParcel/Schedule No. ~ 40# Snow l oad Letter-Manf. Hms. d Soils Report GENERAL NOTES: Planning/Zoning /rroperty Line Setbacks V30ft Stream Setbacks _L_Flood Plain ~ilding Height ~onino Siun-off --t:> t:> _LRoad Impact Fees jjt_HOA/DRC Approval _____Coradeffopography 40% ~anning Issues ~ubdivision Plat Notes No. ----'-'\ 0=-DS=....:::.o ___ _ Assessor's Parcel No. a\~~ ~L-ffi-rqo Date Q~\Q-o:t- BUILDING PERMIT CARD Job Address I~ rr d-3'6-'?;IL.+- OwnerSVV\1\-h. lJ:f.O'/ Contractor ~.'.l ; \Cbt.\ () e,/ AddressStl-T-Phone# '816-09'2.6 Address 2/--140. ~ ISW'r~ C1-Q.tFtPhone # ())S--'S2,2--~ Setbacks: Front _____ Rear _____ RH _____ LH _____ Zoning ____ _ q<lffi.(fe INSPECTIONS Soi Is Test ---,-------;;:,---,----- Footing fO -r -o ll ftb t,._ Foundation _________ _ Grout------------ Underground Plumbing _____ _ Rough PI u mbi ng ---;=;--T't----:----- Framing /1-:2-07~ Insulation fl-1--o:..7J.FiiA Roofing --o?~~c;-:;;~~:----­ Drywall /(-~07 ~ Gas Piping 11-:;L -O 1---;g:;;;c NOTES Weatherproofing __________ _ Mechanical ____________ _ Electrical Rough (State) -;;-;:-----:o::---=---- Eiectrical Final (State) -Z -eJ> Finai3-23"'--@!Checklist ComRieted?---7'::..=..~ Certificate Occupancy_# ~lQ~2~2;;;-ca~-,----:r;:-:,...,.--- Date \<:;,~u_ro 3-2Lo·OCf Septic System # ----'--'N"'--+'/ A~-------- Date ___________ _ Final ___________ _ Other ______________ _ (continue on back) INSPECTION Will NOT BE MADE UNLESS nilS CARD IS POSTED ON THE JOB 24 HOURS NOTICE REQUIRED FOR INSPECTIONS BUILDING PERMIT GARFIELD COUNTY, COLORADO Date Issuedq.J.9:::P?. ..... Zoned Area ............................... Permit No ... l0§.;?.9. ....... . AGREEMENT In consideration of the issuan~:e of this permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building Inspector and IMMEDIATELY BECOME NULL AND VOID. use WrWtJe . • Add"ss or Legal Dmriplion \:J,CIZ.C (' 2~B • "D \l,-1- Qwner '5'fmth, l,p£1)\1 Conlractor R .1Ji\\\eL Setbacks Front Side Side Rear This Card Must Be Posted So It is Plainly Visible From The Street Until Final Inspection. INSPECTION RECORD Footing reJ ·-i -<rL .4.s L Driveway Foundation Underground Plumbing Insulation )) -/-01 J{Jrvv Rough Plumbing Drywall II-{;'-V/ Qr,A Chimney & Vent Electric Final (by State Inspector);/-2 <f-o 7 Gas Piping Final ::3J Z3-c;7" .Z<». Electric Rough (By State Inspector) Septic Final Framing j/-1-0/~ Notes: (To include Roof in place and Windows and Doors installed). ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING- WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND. THIS PERMIT IS NOT TRANSFERABLE For Inspections Call384-5003 108 8th Street Glenwood Springs, Colorado APPROVED DO NOT DESTROY THIS CARD Date9-JCt-~ By fs1lJ IF PLA~-COVER WITH CLEAR PLASTIC Parcel Detail Page I of 3 Garfield County Assessor/Treasurer Parcel Detail Information Asscssor{frc<lswcrPropcny Sc<lr<::h I h5~e_ssor Subset i211m I Ass~_ssor Sllk!LSearch Cl.erk&RecorcleLRe.c.eP!ionSe;Jr<::h Parcel Detail I Value Detail I Sales Detail I Residential/Commercial Improvement Detail Land Detail I Photographs I Tax Area II Account Number II Parcel Number II Mill Levy I I o2o II R041330 II 212533200190 II 45.408 I Owner Name and Mailing Address !sMITH, LEROY D I 11222 COUNTY ROAD 238 I lsiLT, CO 81647 I Legal Description ISECT,TWN,RNG:33-5-91 DESC: A TR IN ITHE S2NW CONT 2.053 AC AKA LOT 2 !ZELENKA SUBDIVISION EXEMPTION. IPRE:R200187 BK:0982 PG:0497 BK:0589 IPG:0121 BK:l803 PG:l6 RECPT:698474 IBK:l669 PG:728 RECPT:60104 BK:l669 IPG:47 RECPT:669952 BK: 1525 PG:672 IRECPT:637929 BK:1525 PG:668 IRECPT:637928 BK:1525 PG:663 IRECPT:637927 BK:l456 PG:l52 I IRECPT:624688 BK:1383 PG:631 IRECPT:610101 BK:1364 PG:788 IRECPT:605776 BK: 1361 PG: 142 IRECPT:604881 BK:l331 PG:837 IRECPT:597916 BK: 1328 PG:20 IRECPT:597116 BK:l312 PG:461 http://www .garcoact.com/assessor/parcel.asp?Parce1Number=212533200 190 9/17/2007 Parcel Detail Page 2 of3 I1RECPT:593814 II Location I Physical Address: jj1222 238 COUNTY RD NEW CASTLEj I Subdivision: I I Land Acres: JJ2.053 I I Land Sq Ft: Jlo I Section II Township II Range I I 33 II 5 II 91 I Property Tax Valuation Information II Actual Value II Assessed Value I I Land: II 125,oooJI 9,9501 I Improvements: II 187,8ooJI 14,9501 I Total: II 312,80011 24,9001 Sale Date: JJ5!22/2006 Sale Price: JJ329,500 Basic Building Characteristics Number of Residential 1 Buildings: Number of Comm/Ind jo I Buildings: Residential Building Occurrence 1 Characteristics I TOTAL HEATED AREA: IJ!,920 ABSTRACT CODE·IISINGLE FAM.RES- . IMPROVEMTS ARCHITECTURAL STYLE: IJMODULAR -UBCIIRCIIBC EXTERIOR WALL: IJMASONITE ROOF COVER: jjCOMP SHNGL ROOF STRUCTURE: IJGABLE INTERIOR WALL: IIDRYWALL I FLOOR: IIHARD TILE I FLOOR: IJcARPET I http://www .garcoact.com/assessor/parcel.asp ?Parce1Number=212533200 190 9117/2007 Parcel Detail HEATING FUEL: IlGAS I HEATING TYPE: IIFORCED AIR I STORIES: STORIES 1.0 I BATHS: 2 ROOMS: 6 UNITS: 1 BEDROOMS: 13 I YEAR BUILT: 112005 I Tax Information I Tax Year Transaction Type Amount I 2006 Tax Payment: Second Half ($579.18)1 2006 Tax Payment: First Half ($579.18)1 2006 Tax Amount $1,158.361 2005 Tax Payment: Second Half ($855.88)1 2005 Tax Payment: First Half ($855.88)1 2005 Tax Amount $1,711.761 2004 Tax Payment: Whole ($390.06)1 2004 Tax Amount $390.061 Top of Page Ass,s~or Dat<tbasg Se<trch Options I Treasurer Database Search Opti.ons Clerk. /k .. ..RecorderD<ll<thm;e SearcJLOptions Page 3 of 3 The Garfield County Assessor and Treasurer's Offices make every effort to collect and maintain accurate data. However, Good Turns Software and the Garfield County Assessor and Treasurer's Offices are unable to warrant any of the information herein contained. Copyright © 2005 -2006 Good Turns Software. All Rights Reserved. Database & Web Design by Good Turns Software. http://www .garcoact.com/assessor/parcel.asp ?Parce1Number=212533200 190 9117/2007 Building Guide Colorado Chapter of the International Code Council How to Use this Guide Provide two sets of plans and complete the following: 1 Complete thiS Building GUide by filling in the blanks on page two and three, and indicating which c;onstruction details will be used. 2 ProVide 2 Plot Plans (site plan) showing dimensions of your project or addition and its relationship to existing buildings or structures on the property and thte distance to existing property lines, drawn to scale. a Fill out a buDding permit application. The majority of permit applications are processted with little delay. The submitted documents Will help determine if the project is in compliance· with building safety codes, zoning ordinances and other applicable laws. The Colorado Chapter of the International Code Council is a professional organization seeking to promote the public · heatth, safety and welfare to building construction. We appreciate your faeclback and suggestions. To obtain a master copy of this building guide, please write to the Colorado Chapter of the lntemational Coda Council, P.O. Box 961, Arvada, CO 80001. This handout was cleveloped by the Colorado Chapter of the International Code Council as a basic plan submittal under the 2003 International Residential Code. It is not Intended to cover all circumstances. Check with your Department of Building Safety for additional requirements. 1 Single Fantily Residential One Story Detached Garage Directions 1. Fill in the blank~ on pages Z and 3 with dimensions and materials which wlll be used to build the structure. Please print legibly. 2. Indicate in the check boxes on page 3 which detail from page 4 will be used. Note: Heated garages may require special provisions. Floor PJan '---====:.ID. . ;L~' 1.===------i ,-l liDenswn J Locate and detail bracing ( o Garage is heated J ~arage is not heated Indicate rafter or truss direction Show door and window header sizes and location and size of tanding tn front of door ( 3'h" minimum concrele •lab) r ~) . ;i_ X .(O'.s header J L..::. {Wrnp/s: {2) 2 K 10 Note: If roof trusses or rafters bear on header. special header design may be required 1 ..---Double 2x4 or 2x6 trimmers each 11 '/ end of overhead door header Garage door opening Floor slope ~~ ---:-----1•*""1 -=:::::={Garage door opening width Z&" }:;:::=--+1•.--.--..-+l•l * 2' s• minimum. with plywoocl sheathing on outside of entire wall with hold downs.lf less than 2' 8", engineering may be required. This handout was developed by the Colorado Chapter of the International Code Council as a basic plan submittal under the 2003 International Residentia l Code. It Is not intended to cover all circumstances . Check with your Department of Building Safety for additional requirements. 'f' Sittgle Fantily Residential 011e Story Detached Garage Note: For roofs with slopes less than 4:12, follow manufacturer's instructions for low slope application of roofing material. or 2x . rafters spaced n O.C. Sheathing '(:L c ~ i3 . CflBQ<m;;r;; box -<Jr-2 x 10"'J.?afr«S Spa"CtXii4 • 0 .0.) (t~Mmple; 'It ' BX!Srior plywood) Minimum lx __ ridge board (8:xampls : 1 :X Note: Pre-enginee red roof trusses w/truss clips may be used in lieu of roof structure shown. _,....._-+-Diagonal wind bracing or braced wall panels @ comers and each 25' of wall. ./Cli'Eoundlaticm Detail A Founaat.on Detail B 4) This handout was developed by the Colorado Chapter of the International Code Council as a basic plan subminal under the 2003 International Residential Code. II is not intended to cover all circumstances. Ch&ek with your Department of Building Safety for additional requirements. Ceiling Insulation tz.-3~ (1/lriJ<Jt!Jd -s:xamp/8: ~-38) 2x_g__ceiling joists@ &O.C. (s:xampls! 2 :x 8 ct 24" O.CJ Double 2x__Ltop plate (B:xamp/a: 2 X 8) Cont. 2x...1_sill plate {sxam~: 2 x 6) Wall lm-Ulation 12 -'( 4 (If h~~al8d • liX'dn!&J/8: R·19 FJbsrglilss Batts) Footing size_x_ (ex811!pls : 8' :X 16~ ~--------------------~·3 Single Fatnily I~c .~idential ()nc Story Jlctached Ga1·age Foundation Detail A Lap sid ing over foundation a minimum of 1'. Finish ed grade Note: Check with local bulldihg department for swelling soils. Ca issons may be required . Foundation f)ctail B Lap siding over foundation 11 minimum of 1 • Finished grade Note: Check wi th local building department for swel lin~ soil s. Caisson s may be requ tred . 36" min . Thi3 handout was develop&d by the Colorado Chapt er of the lntQrnatlona l Cod e Council as 11 basi c plan subminal under the 2003 International Resicl llnti.ll Cod e. It 16 not Intend ed to cover all circum stances. Check Mth your DepartmQot of Building Safety lor acldltionaJ requlrQments . W x 1 0' steel anchor bolts 6'·0' O.C. max., 7' min. penetrati on max. 12' from comer and 1 2' from each ind of plate (min. 2 botts per plate). Bottom plate shall be min . 8" above grade, or be treated wood or decay resistive wood #4 reba r min. cont . top & bottom * \ ... < 16 W' x 10' steel anchor bolts 6'·0" O .C. max., 7" min . penetration max. 12" from comer and 12' from each end of plate (min. 2 bolts per plate ). Bottom plate shall b• min. 8" above grade, or be treated wood or dvcay resistive wood 3 W Minimum concrete slab Fiberboard ~rKpansion joint '''101"H-----Provide #4 rebar vert. @ 4'.0 " O.C. Insert reba r into ocncrete footlng or key way #4 rebar min . conti nuous lop of S1emwall & at footing ~--------------------;4 Ml CASITA REAL ESTATE 970 945 2450 P.03 • lm~r~vement Loc~lion Certificate --7 f Lot,,2, Zelenka SubdNISion fxempt1on • G~~;~~::· Colo10~ CORNell OF Sf(;TIOH JJ, TSS, R91W ONE-STORY WOOD FRAME HOUSe HOUSE CIETAIL SCALE; 1'" 20' N~O'OO'OO'E LOT2 .p'.x,y ... ~ "' "ii'l .. >-{ ~. c. .1'"( t-llo lU2&.j 0M.AU' J)~rL ____ .,/ h :..;;~" ~ jQ,OO' ACCfS$.1. UlllWE. 1 h.nby nMyrhollhi• imp....,..m•nl !aeolian collilico!o....rt !)I"OilD,.j lo.: lh.l fl-ltt,:lr, lhbl il 01 Ml G lo"d WIW)' pial..-1mprov.,menl 1vrvoy pial, and lhol il;. 110llo l,,.l;.d vpon lar!ho .. loblflhllllnl tl fiMI, bulldi~Q, or 01~111 fvrvt• imll"'"~mtnl hn01. . . I Ntth~r ullify lhollht imgrOWI'II!IIIIIn lht <:~b11vr t:lowibed por~•l on!l.i•<lol~ • .li..n~ 9,10M, .;U~IIJ"IijjJ.t t,Mi<~ohl, 6ro ~~lirolrwil~in lho bou~darftj, of. \I,. pareol. aupl ao rhO'olm,lhollh"o ar. M """'""dm1Mh upon lhe d<ml~ Pf<mi•••lry im~ro~~ll o~ MJ"Odjoi~iM-Q pwniJst, n"pl 111 indio:tl3d, and lkallh1r1 iii'O III!DOftl~ tv!~IMI ~ ai~n of 011~ ~~$mini U<lllii"IQ or but dolling Ot11 )l"(lol of !old l!llfCII, ACI~IIX ~gl1d, NOTtS1 Thd rNI pr4p•"V dm.rib•d ahav& do•• oo! li•wilhi~ lh•IOmiiJ Dlo 100 Year flood Haror~ DOIII'odal')'. Flores Residence 1