HomeMy WebLinkAboutPlansGENERAL STRUCTURAL NOTES GENERAL REQUIREMENTS 1. Design Is based on the 2003 edition oP the International Residential Code ORO). 2Design Live Loads: a. Roof (Snow) 40P9F b. Residential Floors 40P5F c. Pecks 60P5F d. Wind 40 MPH Basic Wind Speed, 3 second gust 3AII dimensions, elevations and details on structural documents shall be verified against the architectural documents prior to construction or fabrication. 4.The contract structural documents and specifications represent the completed structure. The contractor shall provide all measures necessary to protect the structure and existing adjacent structures and utilities. 5.Coordinate all openings through floors, walls and roofs with Mechanical and Electrical Contractors. Notify Engineer of any openings to be cut In structural systems. FOUNDATIONS 1. Foundation Design Is based on Solis Report *101 -I% -I by Hepworth-Pawlak Geotechnical, Inc., dated April 13, 2006. The Contractor shall review the Soils Report and follow all recommendations therein, Including, but not limited to excavation, site conditions, drainage, backfill and compaction, slob -on -grade construction, drainage systems, and site inspection requirements. 2.Avold excessive wetting or drying of the excavation, keeping the excavation reasonably free of water during placement of concrete for footings. CONCRETE AND REINFORCING STEEL IAll concrete shall attain 3,000 P5I compressive strength within 28 days. 2.Use Type I-11 Portland Cement (ASTM 050) with 4-6% air entrainment. Concrete aggregate to be normal weight (stone). 3.Per&orm all cast -In -plats concrete work In accordance with Specifications for Structural Concrete for Bulldings" AGI 901-84, unless noted otherwise. Provide hot or cold weather protection per AGI 305 or 506. 4.ReinPorcing steel shall conform to ASTM A6151 *4 and smaller (rade 40, *5 and larger ■ Grade 60. 5.Horizontal reinforcing steel shall be made continuous by lapping bars a minimum oP 52 bars diameters at all splices and providing corner baro. Fabrication and Installation of reinforcing steel shall conform to AGI 515. 6.Provide accessories necessary to properly support reinforcing at the positions shown on the dow ments. 1.Calclum chloride or admixtures containing more than 0.05% chloride Ions or thiocyanates are not permitted. 8Do not place pipes, ducts or chases In structural concrete without prior approval of the Structural Engineer. pi Lc. 7-77 PROVIDE STEEL BEARING PLATE 1"x 14"x14" EXISTIN6 CONC. FOUNDATION WALL 4 FT6 EXISTING BASEMENT 5.0.6. SAW -GUY EXISTING FOOTING ® HELICAL PIER LOCATIONS STANDARD BRACKET PROVIDED BY HELICAL PIER SUPPLIER DRILLED HELICAL. PIER- SEE PLAN FOR LOCATION- SEE KEY 4 PLAN NOTES FOR ADDN'L INFORMATION PROVIDE TUBULAR STEEL 2.1/2" SQUARE 51-IAFT- TYPICAL EXISTING CONC. FOUNDATION WALL 1 FT6 UPPER SOILS: SANDY SILTS 4 CLAYS L 51'-O" +/- SEE SOILS REPORT T.O. EXISTING RAVEL Nee CONDITIONS OF PERMIT BLRE-10-11-2236 Paul Allen 108 Riverbend Way Foundation Repair Glenwood Springs, Colorado 1) ALL WORK MUST COMPLY WITH THE 2009 INTERNATIONAL RESIDENTIAL CODE (IRC) AND MANUFACTURER'S INSTALLATION SPECIFICATIONS 2) THIS PERMIT IS ISSUED FOR FOUNDATION REPAIRS ONLY. REPAIRS TO REMAINING STRUCTURE REQUIRE A SEPARATE PERMIT. 3) ENGINEER ON RECORD SHALL FIELD VERIFY HELICAL PIER INSTALLATION. ENGINEER STAMPED APPROVAL REPORT IS REQUIRED FOR FINAL INSPECTION. 4) ADDITIONAL STRUCTURAL FOUNDATION DEFECIENCIES ENCOUNTERED DURING REPAIRS REQUIRE ENGINEER STAMPED DETAIL/APPROVAL FOR REPAIRS. 5) SEE PLAN ATTACHMENTS FOR CARBON MONOXICDE (CO) ALARM REQUIREMENTS IN EXISTING STRUCTURE. 6) GARFIELD COUNTY FINAL INSPECTION REQUIRED. EXTEND HELICAL PIER INTO COMPETENT BEARING SOILS (DENSE GRANULAR SOILS) 4 PROVIDE A SAFE WORKING LOAD OF 25,000 LBS. MINIMUM UNLESS NOTED OTHERWISE CONC. FOUNDATION WALL @ UNDERPINNING I" = I' -O" EXISTING BASEMENT 5.0.6. L '1 a Q 4 '1 G r ▪ \ TYPICAL TIEBACK GORE DRILL S" dia. HOLE THRID EXIST. WALL T.O. SLAB 55'-10" 4 /,1;7/r>17 /)7Vg. , //!fir r/2-5 :j,; %/' l' ; /.S DRILLED 4ELICAL TIEBACK (SEE KEY 4 PLAN NOTES) 12'-O" MINIMUM 111 • 1'-01 1 /1'Y/5/ '7/41/ //,5 Qat el' //'-A/&__ ow�4 i Z 'rf>%�` ; 7r S fit'! t/e - /1/'. cif 5-9,7,1r, VED TO NOTE!) i.�l. y, Id Ill —lR itIsPF0 t,VyHS :1.";/:.1.41 , ii :19 U N'r'' ;a"'Y t. f"" , R' ele it" MW `T'E'S; ON WITHOUT Ila ).Y. MANS ON SITE Z KURTZ ASSOG I ATES, NG. 5012 COUNTY W. 154 GLENWOOD SPRINGS, COLORADO (G110) Q45-6305 PAUL KANDIGE ALLEN RESIDENCE 108 RI VERBEND WAY, 1 RONBRI DGE SUBDIVISION, GARFIELD COUNTY, COLORADO DRAWNBY: CHECKED BY: B.J.K. SCALE: AS SHOWN PROJECT #: II -32 DATE: 0N4TI..,KTIQN SET: 10/04/11 SHEET TITLE: GENERAL NOTES DETAILS; SHEET: 03 03 0- C- 03 zd w et Lk) Nt 14 V- \ICI* O 3 coco Ca M O LO ISI G m L d O_C Q! � =To 0 = 0 L TI m GARAGE 52'-4" IP' -1" Iq'-6" L TW=82'10" TW=88'-10" m TW=q8'-1" TW=q2'-O" (WINDOW SILL) TW=q6'-10" TW=q4'-10" 4'-4" 6'-5" 6'-0" L_ 3'-2 3'-2 MAIN LEVEL ABOVE: T.O. PLYWD■ 100'-0" 1.11.5 STEEL BEAM ABOVE WALK -OUT BASEMENT SLAB -ON -GRADE T.O. SLAB■ 88'-10" 6'-6 LOWER LEVEL Or RESIDENCE 6'-6 3'-3 3'-3 6'-0" sec W18 STEEL BEAM ABOVE /4.•, -i11 -(7111/144"4/-115, q /[2 4 -,(LA iz, i UP 3'-0 (C .11.1f t1 f 6'-1" 3'-O TW=q2'-0" (WINDOW SILL) 6'-1" TIN= q6'-10" T11=q4'-10" 4'-4" �-- TW -412'-10" H,P.rr SEE A/SI- TYPICAL /'/ 2'-i" -BEE B/51 - TYPICAL —ly_ 2 8 \ H.P. 30000 lbs. 12'-0" I� H.P. PATIO CONCRETE ATIOCONCRETE SLAB H.P. 12'-0" y4L-f;;. 30000 Ib$. _I I 10'-10" H.P x 10'-"1" H.P. 3'-0" 51'-0" KEY H.P.= HELICAL PIER TO BE INSTALLED (13 TOTAL) T.B.= TIEBACK TO BE INSTALLED (3 TOTAL) FOUNDATION FLAN 1/4"•I'-0" ED PLAN NORTH TW=88'-10" /._ '/..;' //67/• //et' 77- FOUNDATION FOUNDATION PLAN NOTES: 1. Existing concrete foundation walls are 8" thick unless noted otherwise 0.1.N.0) 2. Dimensions this sheet are to Pace oP concrete U.N.O. 3. Helical Piers (HP) to S installed to achieve a minimum safe working load= 25,000 lbs. unless noted otherwise on plan, with a minimum Installed length= 8'-0". 4. Tiebacks MB) to be Installed to achieve a minimum safe working load (pull-out strength)= 12,000 lbs., with a minimum installed length■ 12'-0". 5. T.W.= top of existing concrete wall. 6. 't Stop top oP concrete wall. *Th7. designates timber post supported on Patio Slab. KURTZ 4 ASSOCIATES, INC. 5012 COUNTY W. 154 GLENWOOD SPRINGS, COLORADO (G1-10) ai45-6305 PAUL 4 KAND ICE ALLEN RESIDENCE IOS RIVERBEND WAY, I RONBR I DGE SUBDIVISION, GARP IELD COUNTY, COLORADO DRAWN BY: M.C.E.K. CHECKED BY: B.J.K. SCALE: AS SHOWN PROJECT it.; II -32 DATE: CONSTRUCTION SET: • 40/04/11., SHEET TITLE: FOUNDATION SHEET: