Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutApplication-PermitDavid Bartholomew
From: David Bartholomew
Sent: Wednesday, August 04, 2010 12:17 PM
To: 'john chromy'
Cc: Andy Schwaller; Jena Thompson; Julie Taylor
Subject: RE: 3313 County Road 113
They'll be here. Thanks for getting back to me.
David
From: john chrorny {mailto:whipples2@rof.net]
Sent: Wednesday, August 04, 2010 12:06 PM
To: David Bartholomew
Subject: Re: 3313 County Road 113
Dave,
Thanks for your patients, thought 1 was going to get down to see you by now but not looking good.
I am sending our feild man, Sam Wright. He will pick the plans up this week.
Thanks,
John
Original IVIessage_-----
.F.roin David Bartholomew:
To: John chromy
Cc: Andy Schwaller ; Jena Thompson ; Julie Taylor
Sent: Tuesday, July 27, 2010 4:14 PM
Subject: RE: 3313 County Road 113
John,
Would you like to pick up the original plans or should we dispose of them?
Thanks,
David
From: john chromy [mailto:whipples2@rof.net]
Sent: Tuesday, July 27, 2010 3:44 PM
To: David Bartholomew
Subject: 3313 County Road 113
Parcel No. 239310400006
RE: 2009 Building Permits
Dave Bartholomew; Plans Examiner,
In the Fall of 2009, Whipple and Brewster applied for building permits at 3313 County Road 113, for a Dwelling
Unit (Permit Number: BLRE-10-09-1305) and an Accessary Building (Permit Number: BLRE-10-09-1303).
The drawings where dated: PERMIT 6 Oct 09, and submitted to Garfield County on Oct. 8, 2009. This submittion has
been superceeded by a new submittion dated: Permit 6-8-10, and assigned
Permit Numbers, BLRE-6-10-1587 and BLRE-6-10-1588, respectiviey.
Please contact me, if any addittional information is needed.
1
Thanks,
John Chromy
Whipple and Brewster Corp.
2
GARFIELD COUNTY BUILDING PERMIT APPLICATION
108 8'h Street, Suite 401, Glenwood Springs, Co 81601
Phone: 970-945-8212 / Fax: 970-3843470 / Inspection Line: 970.384-5003
www.aarfield-countv.com
I
Parcel No: (thisinformation i�vallable at the assessors office 970-945-9134) 134-1--10
2
Job Address: (if an address has not been psigned, please provide Cr, Hwy or Street Name & City) or arid leg 1 description
i (9043
x5
Lot No: Block No: bd./ Exemption,:
)0,5 i0;,, t0 ,: is 12 88 S Q - 6. . n�
Mist Fees:
.,or
Owner: (roperty owner)
L�C�ed' ' to ki:r.f '
Mailing Address:
I L1 Sa (1e vtr, ) ei
Ph:
gm 720 2
Alt Ph;
5
Contractor: I
Mailing Address:,
Ph:
Alt Ph:
6
Archite t / Engi. ee •„
oliaT tAjfiAeetS �>i e
Mailing Address -Ph•,
. a � -o vtiotIAST, a C. ki4,4e
ello l 3 22.5
Alt Ph: --j-.6 (n v+
(0 (g'4
7
Sq. Ft. of Building_ i g fSq.
Ft. or Acres of Lot: Z j 1g. /+
Height: , i' p�
No. of Floors:
8
Use of Building:g�.
4-�" 90 (
�..� -.moi* * '. i —�ANrk i . eG U.) loji„.a+
#oil
e
9
Describe Work: .^
,V.,,, rwt
10
Class of Work:
New o Alteration a Addition
11
Garage: r
Attached Detached
Septic: •
RSDS tl Community
12
Driveway Permit:
Owners valuation of Work: S
Authority.
This application for a Building Permit must be signed by
letter of authority, signed by the Owner, must be provided
A Building Permit cannot be issued without proof of legal
NOTICE
the Owner of the property, described above, or an authorized agent. If the signature below is not that of the Owner, a separate
with this Application.
and adequate access to the property for purposes of inspections by the Building Department.
Electrical Perini[, (2) County ISDS Permit, (3) another permit required for use on the property identified above, e.g. State or
Discharge Permit.
authorized is not commenced within 180 days of the date of issuance and if work is suspended or abandoned for a period of 180
CERTIFICATION
contained above is true and correct I understand that the Building Department accepts the Application, along with the plans
based upon my certification as to accuracy.
a Building Permit will be issued granting permission to me, as Owner. to construct the structure(s) and facilities detailed on
and my agents will comply with provisions of any federal, state or local law regulating the work and the Garfield County Building
Regulation(s)). I acknowiedge that the Building Permit may be suspended or revoked, upon notice from the County, if the location,
are not in compliance with County Rea iation(s) or any other applicable law.
described above, to inspect the work. 1 further acknowledge that the issuance of the Building Permit does not prevent the
if any, discovered after issuance: or (2) stopping construction or use of the structure(s) or facility(ies) if such is in violation
work by the Building Department do not constitute an acceptance of responsibility or liability by the County of errors, omissions
compliance with federal, state and local laws and County Regulations rest with me and my authorized agents, including without
THE NOTICE & CERTIFICATION ABOVE:
CJ
Legal Access.
Other Permits. Multiple separate permits may be required: (1) State
County Highway/ Road Access or a State Wastewater
Void Permit_ A Building Permit becomes null and void if the work
days after commencement,
I hereby certify that I have read this Application and that the information
and specifications and other data submitted by me or on my behalf (submittals),
Assuming completeness of the submittals and approval of this Application,
the submittals reviewed by the Building Department.
In consideration of the issuance of the Building Permit, I agree that 1
Code, ISDS regulations and applicable land use regulations (County
construction or use of the structure(s) and facility(ies), described above,
1 hereby grant permission to the Building Department to enter the property,
Building Official from: (1) requiring the con-ection of errors in the submittals,
of County Regulation(s) or any other applicable law,
Review of this Application, including submittals, and inspections of the
or discrepancies, As the Owner, I acknowledge that responsibility for
limitation my architect designer, engineer and/ or builder.
I HEREBY zKNOWLEDGE THAT I VE READ AND UNDERSTAND
RS; GNAeTUR DA '
STAFF USE ONLY
Special Conditions: le 6p4- .-13V5
So
Adjusted Valuation:
Plan Check
Fee: api "cti
Permit Fee: 3 35.
x5
Manu home Fee:
Mist Fees:
ISDS Fee:
Total Fees: 55 3./to
-1Z11-7P.
Fees Paid:
/1 5
C?/1--
Balance Due: 17. 3
-7grWg.0
BP No & Issue Date:
ISDS No & Issued Date:
1 -503
Setbacks:
OCC Group:
1FZ,
Const Type:
r r
(F6,te✓
Zoning:
BLD Y DEPT:
PLNC DEPT:
'V \\W\\'N (6/(4/01 .
APPROVAL DATE
APPROVAL DA I E
The following items are required by Garfield County for a final inspection:
1) A final Electrical Inspection from the Colorado State Electrical Inspector.
2) Permanent address assigned by Garfield County Building Department and posted at the
structure and where readily visible from access road.
3) A finished roof; a lockable building; completed exterior siding; exterior doors and windows
installed; a complete kitchen with cabinets, sink with hot & cold running water, non-absorbent
kitchen floor covering, counter tops and finished walls, ready for stove and refrigerator; all
necessary plumbing.
4) All bathrooms must be complete, with washbowl, tub or shower, toilet, hot and cold running
water, non-absorbent floors, walls finished, and privacy door.
5) Steps over three (3) risers, outside or inside must be must have handrails. Balconies and decks
over 30" high must be constructed to all IBC and IRC requirements including guardrails.
6) Outside grading completed so that water slopes away from the building;
7) Exceptions to the outside steps, decks, grading may be made upon the demonstration of
extenuating circumstances., i.e. weather. Under such circumstances A Certificate of
Occupancy may be issued conditionally.
8) A final inspection sign off by the Garfield County Road & Bridge Department for driveway
installation, where applicable; as well as any final sign off by the Fire District, and/or State
Agencies where applicable.
A CERTIFICATE OF OCCUPANCY (C.0.) WILL NOT BE ISSUED UNTIL ALL THF,
ABOVE ITEMS HAVE BEEN COMPLETED.
A C.O. MAY TARE UP TO 5 BUSINESS DAYS TO BE PROCESSED AND ISSUED.
OWNER CANNOT OCCUPY OR USE DWELLING UNTIL A C.O. IS ISSUED.
OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN
ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES
UNTIL ABOVE CONDITIONS ARE MET.
I understand and agree to abide by the above conditions for occupancy, use and the issuance of a
C.O. for the building identified in the Building Permit.
GeneralInforrnation
Building Plan Review
Description of Work: Accessory building
Bin #: E-1
Location Address: 003313 113 COUNTY RD
CARBONDALE, CO
d l
Contacts
Case Manager: Ken Smith
Plan Case Number: BLDG -10-09-6143
Parcel: 239310400006
Application Date: 10/08/2009
Owner: George S. Whipple
Applicant: George S. Whipple
Applicant Phone: 970-920-4428 Email:
Building
Engineered Foundation
Driveway Permit
Surveyed Site Plan
Septic Permit and Setbacks
Grade/Topography 30%
Attach Residential Plan Review List
Minimum Application Questionnare
Subdivision Plat Notes
Fire Department Review
i
Valuation Determination/Fees
r
Red Line Plans/Stamps/Sticker
r Attach Conditions
_Application Signed
Plan Reviewer To Sign Application
Parcel/Schedule No.
40# Snowload Letter - Manu. Homes
Soils Report
Planning/Zoning
Property Line Setbacks
30ft Stream Setbacks
Flood Plain
Ruilding height
i
Toning Sign -off
Road Impact Fees
HOAIDRC Approval
Grade/Topography 40%
Planning Issues
Subdivision Plat
General Comments:
2624X g7S'x 74.65- tit 7,74 .64
7 J . + 4
74.66
ti(6 gif,91 Jr( it 26
1 ci3gipxr�,= !t.,gSY•-1-"(063.9)
Monday, October 12, 2009
GARFIELD COUNTY BUILDING AND PLANNING
970-945-8212
MINIMUM APPLICATION REQUIREMENTS
For
SINGLE FAMILY DWELLING CONSTRUCTION
Including
NEW CONSTRUCTION
ADDITIONS
ALTERATIONS
And
MOVED BUILDINGS
In order to understand the scope of the work intended under a permit application and expedite the
issuance of a permit it is important that complete information be provided. When reviewing a plan and
it's discovered that required information has not been provided by the applicant, this will result in the
delay of the permit issuance and in proceeding with building construction. The owner or contractor shall
be required to provide this information before the plan review can proceed. Other plans that are in line
for review may be given attention before the new infounation may be reviewed after it has been
provided to the Building Department.
TWO (2) SETS OF CONSTRUCTION DRAWINGS & TWO (2) SITE PLANS MUST BE
SUBMITTEDFOR ALL APPLICATIONS.
Please review this document to determine if you have enough information to design your project
and provide adequate information to facilitate a plan review. Also, please consider using a design
pr©fessionai for assistance' in your design and a construction -professional .for .-construction ...ofyour.
project. Any project with more than ten (10) occupants requires the plans to be sealed by a
Colorado Registered Design Professional.
To provide for a more understandable plan in order to determine compliance with the building, plumbing
and mechanical codes, applicants are requested to review the following checklist prior to and during
design. Applicants are required to indicate appropriately and to submit the completed checklist at
time of application for a permit.
Plans to be included for a Building Permit, must be on drafting paper at least 18"x.24" and drawn
to scale.
1
Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks,
balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line and
original grade. A section showing in detail, from the bottom of the footing to the top of the roof,
including re -bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation,
sheeting, house -rap, (which is required), siding or any approved building material. Engineered
foundations may be required.
A window schedule, A door schedule. A floor framing plan, a roof framing plan, roof must be
designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. wind speed,
wind exposure B or C, and a 36 inch frost depth.
All sheets to be identified by number and indexed, All of the above requirements must be met or your
plans will be returned.
All plans submitted must be in compliance with the 2003 IRC, and 2006 IECC.
1. Is a site plan included that identifies the location of the proposed structure or addition and distances to
the property lines from each comer of the proposed structure(s) prepared by a licensed surveyor
and has the surveyors signature and professional stamp on the drawing? Properties with slopes of
30% or greater must be shown on the site plan. (NOTE Section: 106.2) Any site plan for the
placement of any portion of a structure within 50 ft. of a property line and not within a previously
surveyed building envelope on a.subdivision final plat shall be prepared by a licensed surveyor
and have the surveyor's signature and professional stamp on the drawing. Any structure to be
built within a building envelope of a lot shown on a recorded subdivision plat shall include a
copy of the building envelope as it is shown on the final plat with the proposed structure located
within the nvelope.
Yes
2. Does the site plan also include any other buildings on the property, setback easements and utility
easements? Please refer to Section 5.05.03 in the Garfield County Zoning Resolution if the
property you are applying for a building permit on is Located on a corner lot. Special setbacks do
apply.
Yes
3. Does the site plan include when applicable the location of the I.S.D.S. (Individual Sewage Disposal
System) and the distances to the property lines, wells (on subject property and adjacent
7,properties), teams or water courses?
Yes
4. Does the site plan indicate the location and direction of the County or private road accessing the
property?
Yes
2
5. Have you provided any RESOLUTIONS and/ or LAND USE PERMIT(S) associated with this
property?
Yes if Yes please provide a COPY. No
6. Are you aware that prior to submittal of a building permit application you are required to show proof
of a legal and adequate access to the site? This may include (but is not limited to) proof of your
right to use a private easementJright of way; A. County Road and Bridge permit; a Colorado Dept.
of Highway Permit, including a Notice to Proceed; a permit from the federal government or any
combination. You can contact the Road & Bridge Department at 625-8601. See phone book for
other agerr s
Yes ,�
7. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel
in accordance with the FRC or per stamped engineered design?
Yes
8. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the
clearances required between wood and earth?
Yes No
9. Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces and
soffits?
Yes No
10. Do the plans include design loads as required by Garfield County for roof snow loads, (a minimum
of 40 pounds per square foot up to & including 7,000 feet above sea level), floor loads and wind
loads?
Yes
11. Does the plan include a building section drawing indicating foundation, wall, floor, and roof
construction?
Yes "
12. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists,
roof rafters or joists or trusses?
Yes
13. Does the building section drawing or other detail include the method of positive connection of all
columns and beams?
Yes
14. Does the elevation plan indicate the height of the building or proposed addition from the
undisturbed grade to the midpoint between the ridge and cave of a gable or shed roof or the top
of a flat roof? (Building height measurement usually not to exceed 25 feet)
Yes
3
15. Does the plan include any stove or zero clearance fireplace planned for installation including make
and model and Colorado Phase 11 certifications or phase 11 EPA certification?
Yes No
16. Does the plan include a masonry fireplace including a fireplace section indicating design to comply
with the IRC`
Yes No
17. Does the plan include a window schedule or other verification that egress/rescue windows from
sleeping rooms and/or basements comply with the requirements of the IRC?
Yes
18. Does the plan include a window schedule or other verification that windows provide natural light and
ventilation for all habitable rooms?
Yes
19. Do the plans indicate the location of glazing subject to human. impact such as glass doors, glazing
immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking
surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety
glazing for these areas?
Yes No
20. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on
the plan?
Yes
21. Do you understand that if you are building on a parcel of land created by the exemption process 6r the
subdivision process, are building plans in compliance with all plat notes and/or covenants?
Yes
22, Do you understand that if you belong to a Homeowners Association (HOA), it is your responsibility to
obtain written permission from the association, if required by that association, prior to submitting.
an application for a building permit? The building permit application will be accepted without
it, but you run the risk of the HOA bringing action to enforce the covenants, which can result in
revocation of permit issued. Additionally, your Plan Review fee is not refundable if the plans
have been reviewed by the Building Department prior to any action by the HOA that requires either
revocation o�bstantial modification of the plans.
Yes
23. Will this be the only residential structure on the parcel?
Yes ," No If no -Explain:
24. Have two (2) complete sets of construction drawings been submitted with the application?
Yes
4
25. Do you understa ►. `hat the minimum dimension a home can be on a lot is 20ft.wide and 20ft. long?
Yes
26. Have you designed or had this plan designed while considering building and other construction code
requirements?
Yes
27. Do your plans comply with all zoning rules and regulations in the County related to your properties
zone districty
Yes
28. Does the plan accurately indicate what you intend to construct and what will receive a final inspection
by the Garfield County Building Department?
Yes
29. Do you understand that approval for design and/or construction changes are required prior to the
application of these changes?
Yes
30. Do you understand that the Building Department will collect a "Plan Review" fee from you at the
time of application submittal and that you will be required to pay the "Permit Fee" as well as any
"Road Impact" or "Septic System" fees required, at the time you pick up your building permit?
Yes l
31. Are you aware that you must call in for an inspection by 3:30 the business day before the
requested inspection in order to receive it the following business day? Inspections will be
made from 7:30 a.m. to 3:30 p.rn. Monday through Friday. Inspections are to be called in
to 384-5003
Yes No
32. Are you aware that requesting inspections on work that is not ready or not accessible will result in a
$50.00 re -in ction fee?
Yes
33. Are you aware that you are required to call for all inspections required under the IRC including
approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of the
building?
Yes
5
34. Are you aware that the Permit Application must be signed by the Owner or a written authority being
given for an gent and that the party responsible for the project must comply with the IRC?
Yes
35. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and
Plumber to perform installations and hookups, unless you as the homeowner are performing the
work? The license number of the person performing the work will be required at time of
applicable inspef ion.
Yes
36. Are you aware, that on the front of the Building Permit Application you will need to fi11 in the
Parcel/Schedule Number for the lot you are applying for this permit on prior to submittal of a
building permi application? Your attention in this is appreciated.
Yes
37. Do you know that the local fire district may require you to submit plans for their review of fire safety
issues?
Yes (please check with the building department about this requirement)
38. Do you understand that if you are planning on doing any excavating or grading to the property prior
to issu.anc of a building permit that you will be required to obtain a grading permit?
Yes
39 . Are you aware that if you will be connecting to a public water and/or sewer system, that the tap
fees have to be paid and the connections inspected by the service provider prior to the issuance of
a Certificate of Occupancy?
Yes
40. If you anticipate obtaining a water tap from the City of Rifle, please provide a letter indicating that
the City will provide water service. No building permit application will be accepted without such
a letter.
Yes
I hereby acknowledge that I have read, understand and answered these questions to the best of
ity.
"urea Owne
r !
Phone�l7t W ` ZC (days);
/ch £ c
6
Date
l ` 1b 3_ g9 1 t'p(evenings)
GARFIELD COUNTY
BUlLDIVG REQ1JIRFMENTS
Codes: 2003 IRC, IBC, IFGC, IMC, IPC, 2006 IECC.
Setbacks: Check subdivisions and zone district for setback requirements.
Snowload (measured at the roof! Not ground): 40PSF up to 7000ft. elevation.
50PSF 7001ft to 8000ft.
75PSF 8001ft to 9000ft.
100PSF 9001 to 10000ft.
Seismic design category: 13
Weathering probability for concrete: Severe.
Termite infestation probability: None to slight.
Wind speed: 90mph.
Decay probability: None
Wind Exposure: B or C (see section R301.2.1.4)
Frost Depth: 36in. to 8000ft. elevation. 42in. 8001 and above.
Winter Design Temperature: Minus 2 to 7000ft.; minus 16over 7000ft. elevation.
Air Freezing Index: 2500deg F -days to 7000ft.; over 7000ft. to be determined by Building official
Ice shield under-layment required.
Mean Annual temp: Variable
Insulation: Windows/doors U=.35, Skylights U=.6, TBL 402.1.1, 2006 IECC.
Minimum R -Values:
Ceilings/roofs R values are R-38 stick built structures. R38 log
construction and steel rafter construction.
• Walls R values are R-19 wood frame; R-19 cavity R-3 sheathing or R-10
sheathing for steel studs.
• Floors R -values are R-30 or enough to fill cavity.
• Basement wall R -values are R-10 below grade, R-19 above grade.
• Slab perimeter R -values and depth is R-10/24in
• Crawl space wall R -value are R-10 below grade and R-19 above grade.
If floors over crawl space are not insulated, the crawl space walls rnust be insulated. Basement wall must be
insulated to frost depth. Common walls garage to house must have R-19 insulation. Common ceiling/floor
garage to house must have R-19. Take precautions to protect plumbing in these areas.
bpminreqsfMar2009
8
Project Name:
AC--ec-25 c)\('
Project Address: 13 CON vti
Notes:
111 c2,4i \e3,4)4 ajc.
If any required information is missing delays in issuing the permit are to be expected. Work may not
proceed without the issuance of a permit. if it is determined by the Building Official that additional
information is necessary to review the application and plans to determine minimum compliance with the
adopted codes, the application may be placed behind more recent applications for building permits in the
review process and not reviewed until required information has been provided and the application rotates
again to first position for review, delay in issuance of the permit or delay in proceeding with
construction.
bpminregsfMar2009
7
App)icattion for Driveway Permit
Person Obtaining Permit: Whipple & Brewster Corp. Permit Number: G.RB09-L)-48
Application Date: 10/06/2009 Termination Date: 11/06/2009
County Road Number: 113 (CATTLE CRE. District: 1 Inspector: fake Mall
hereby requests permission and authority from the Board of County Commissioners to construct a driveway approach (es)
on the right-of-way off of County Roadj i3 (CATTLE CREEK), 3313 East of intersection, located on the ,North
side of road for the purpose of obtaining access to property.
Applicant submits herewith for the consideration and approval of the Board of County Commissioners, a sketch of the
proposed installation showing all the necessary speeiflkation detail including:
1. Frontage of lot along road.
2. Distance from centerline of road to property line.
3. Number of driveways requested
4, Width of proposed driveways and angle of approach.
5. Distance from driveway to road intersection, if any,
6. Size and shape of area separating driveways if more than one approach.
7. Setback distance of building(s) and other structure improvements.
S. No unloading of equipment on county road, any damage caused to county road will be repaired at subdivision
expense.
9. Responsible for two years from the date of completion.
General Provisions
1) The applicant represents alI parties in interest, and affirms that the driveway approach (es) is to be constructed by
him for the bona fide purpose of securing access to his property and not for the purpose of doing business or
servicing vehicles on the road right of way.
2) The applicant shall furnish all labor and materials, perform all work, and pay all costs in connection with the
construction of the driveway(s). AIL work shall be completed within thirty (30) days of the permit date:
3) The type of construction shall be as designated and/or approved by the Board of County Commissioners or their
representative and all materials used shall be of satisfactory quality and subject to inspection and approval of the
Board of County Commissioners or their representative.
4) The traveling public shall be protected during the installation with proper warning signs and signals and the Board
of County Commissioners and their duly appointed agents and employee shall be held harmless against any action.
for personal injury or property damage sustained by any reason of the exercise of the Permit. •
5) The Applicant shall assume responsibility for the removal or clearance of snow, ice, or sleet upon any portion of
the driveway approach (es) even though deposited on the driveway(s) in the course of the County snow removal
operations.
2009-10-06 11:41 970 625 8601 Page 2
6) Itt the event it becomes necessary to remove any right-of-way fence, the posts on either side of the entrance shall
be surely braced before the fence is cut to prevent any slacking of the remaining fence and all posts and wire
removed shall be turned over to the District Road Supervisor of the Board of County Commissioners.
7) No revisions or additions shall be made to the driveway(s) or its appurtenances on the right-of-way without
written permission of the Board of County Commissioners.
8) Provisions and specifications outlined herein shall apply on all roads under the jurisdiction of the Board of County
Commissioners of Garfield County, Colorado, and the Specifications, set forth on the attached hereof and
incorporated herein as conditions hereof.
9) Final inspection of driveway will be required upon completion and must be approved by person issuing
permit or representative of person issuing permit.
The inspection and sign off must be done prior to any CO from the Building and Planning
Department being issued.
10) Contractor agrees to all Provisions in Exhibit A.
Special Conditions:
1. Driveway Width- 32ft
2. Culvert required? False Size: N/A
3. Asphalt or concrete pad required? True Size of pad: 32'xIO'x4"
4. Gravel portion required? True Length: 40'
5. Trees, brush and/or fence need to be removed for visibility? False
6. Distance and Direction.
7, Certified Traffic Control Required? False
S. Work zone signs required? True
In signing this application and upon receiving authorization and permission to install the driveway approach (es)
described herein the Applicant signifies that he has read, understands and accepts the foregoing provisions and conditions
and agrees to construct the driveway(s) in accordance with the accompanying specification plan reviewed and approved
by the Board of County Commissioners.
Signed:
Addressi
ipp e Brew er'Corp.
/ 19-i 5 ga, ,Sa1Gt at l2Lo 7 erl 10-10 Sly
Telephone Number e176 - 99-0 —.442
Permit granted 10/06/2009, subject to the provisions, specifications and conditions stipulated herein.
For Board of County Commissioners' of Garfield County, Colorado:
(7.6,6eorit,
Representative of Garfield County Road and Bridge Signature
2009-10-061141 970 625 8601
Page 3
Specifications
A driveway approach is understood to be that portion of the county road right -of way between the pavement edge
and the property line that is designed and used for the interchange of tragic between the roadway and abutting
property.
2. At any intersection, a driveway shall be restricted for a sufficient distance from the intersection to preserve the
normal and safe movement of traffic. (It is recommended for rural residence entrances that a minimum
intersection clearance of 50 feet be provided and for rural comtnercial entrances a minimum of 100 feet be
provided.)
3. All entrances and exits shall be so located and constructed that vehicles approaching or using them will be able to
obtain adequate sight distance in both directions along the county road in order to maneuver safely and without
interfering with county road traffic.
4. The Applicant shall not be permitted to erect any sign or display material, either fixed or movable, on or
extending over any portion of the county road right-of-way.
5. Generally, no more than one approach shall be allowed any parcel or property the frontage of which is Less than
one hundred (100) feet. Additional entrances or exits for parcels having a frontage in excess of one hundred 100)
feet shall be permitted only atler showing of actual convenience and necessity.
6. All driveways shall be so located that the flared portion adjacent to the traveled way will not encroach upon
adjoining property.
7. No commercial driveway shall have a width greater than thirty (30) feet measured at right angles to the centerline
of the driveway except as increased by permissible radii. No noncommercial driveway shall have a width greater
than twenty (20) feet measured at right angles to the centerline ate driveway, except as increased by
permissible radii.
8. The axis of an approach to the road may be at a right angle to the centerline of the county road and of any angle
between ninety (90) degrees and sixty (60) degrees but shall not be less than sixty (60) degrees. Adjustment will
be made according to the type of traffic to be served and other physical conditions.
9. The construction of parking or servicing areas on the county mad right-of-way is specifically prohibited.
Commercial establishments for customer vehicles should provide off -the -road parking facilities.
10, The grade of entrance and exit shall slope downward and away from the road surface at the same rate as the
normal shoulder slope and for a distance equal to the width of the shoulder but in no case less than twenty (20)
feet from the pavement edge. Approach grades are restricted to not more than ten percent (10%).
11. All driveways and approaches shall be so constructed that they shall not interfere with the drainage system of the
street or county road. The Applicant will be required to provide, at his own expense, drainage structures at
entrances and exits, which will become an integral part of the existing drainage system. The Board of County
Commissioners or their representative, prior to installation, must approve the dimensions and types of all drainage
structures.
Note: This permit shall be made available at the site where and when work is being done. A work sketch or
drawing of the proposed driveway(s) must accompany application. No permit will be issued without drawing,
blueprint, or sketch.
2009-10-06 11:42
970 625 8601 Page 4
Porus Nd'
GWS -25
APPLICANT
OFFICE OF THE STATE ENGINEER
COLORADO DIVISION OF WASE i RESOURCES
818 CantemnJai Btdg., 1313 Sherman SL, Denver, Colorado 8043
(343) 568.3 a1
GEORGE S WHIPPLE
% PATRICK & STOWELL PC
730 E DURANT ST #200
ASPEN CO 81611-
(970)920-1028
1611-
(970)920-rt028
PERMIT TO USE AN EXISTING WEU..
1095
WELL PERMIT NUMBER Lalt % S -F
DIV. 5 CNTY. 23 WD 38 DES. BASIN MD
Lrrt Bionic. Filing: Subdiv:
APPROVED WELL LOCATION
GARFIELD COUNT!
NW 1/4 SE 1f4 Section 10
Twp 7 S RANGE 88 W 61h P.M.
DISTANCES FROM SECTION UNiES
2890 Ft from North Section Line
2000 Ft. from East Section Line
ISSUANCE OF Tl-i(S PERMIT DUES NOT CONFER A WATER RIGHT
CONDM NrRS OF APPROVAL
1) This well shall be used in such a way as to cause no material injury to existing water rights. The issuance of the permit does
nal assure the appifcant that no injury well occur to another vested water right or preclude another owner de vested water right
from seeking relief to a Cvii court action.
2) The construction of this well staff be in compliance with the Water Weil Construction Rues 2 CCR 402-2, :mess approval of a
variance has been granted by the State Board of Examiners of Water Well Construction and Pump Installation Contractors In
accordance with Flute 18.
3) Approved pursuant to CRS 37-90.137;2y For the replacement of an existing well, pandit no. 48356-F (decreed by the Division 5
Water Court as the Whip Well, case no. 95C4t 37) on the condition that this well is oc, stated in accordance with the George S.
Whipple plait for augmentation approved by the Division 5 Water Court in case no, 95CW33a. if the well is not operated in
accordance with the terms of said decrees, it will be subject to adMinistratton inducting orders to cease pumping,
4) The old well must be plugged according to the Water Well Conetruction Rules. .A Wel Abandonment Report must be submitted
within sixty (60) clays after construction of the new well, affirming that the old well was plugged.
The use of ground water horn this well Is ianrtec to ordinary household purposes inside one single family dwelling, storkwaterirg,
and the Irrigation of up to .35 acre of lawns and gardens.
6) The maximum pumping rats sttalf not exceed 15 GPM.
• 7) The annual amount of ground water to be with drawn shall:net exceed 283 acre-feet.
AI) MIS well shall be located not mors than 200 feet from the location deed for the Whip well ?n case no, 95CW337 and not more
man 203feet from trte location specified on ails permit.
9) A .i tallzing flow meter must be installed on the weft and maintained in good working order. Permanent records of all diversions
roust be maintained by the well owner (recorded at least annually) arra submitted to the Divisions Engineer upon request.
10) The rata: n flow from the use of the well roust be through an :ndivids al waste water" dispersal system of the non -evaporative type
where the water Is returned to the same stream system In which the well is ;orated.
11) The owner shall mart the well In a conspicuous spic uous place with Well permit number(s), name of the aquifer, and court case number(s)
as appropriate The owner shalt take necessary means and precautions to preeerve these markings.
12) Approved for the Installation cf a pump in, and the use of, an existing well, constructed on Jure 25, 1998,10 a depth of 333 feet,
under rncntoring hoe notice M1 33782, received Jure 19, 199B. 4L (0(2(4r
APPROVED
i41W
Gn neer
Receipt No, 0434627
970 927 3801
2005-10-0111:32
DATE ISSUED OCT 0 6 1998 EXPIRATION DATE O C T 0 `'' a
Page 1
Parcel Detail
Garfield County Assessor/Treasurer
Parcel Detail Information
Pagel oE4
Assessor/Treasurer Property Search 1 Assessor Subset Query 1 Assessor Sales Search
Clerk & Recorder Reception Search
Basic Building Characteristics 1 Tax Information
Parcel Detail 1 Value Detail I Sales Detail I Residential/Commercial Improvement Detail
Land Detail I Photo ra hs 1 Mill Levy Revenues Detail
Tax Area
011
Account Number
R050100
Parcel Number
239310400006
2008 Mill Levy
60,542
Owner Name and Mailing Address
WHIPPLE, GEORGE STEPHENSON &
WH I PPLE, LYDIA B
1215 GALENA STREET
ASPEN, CO 81611
Assessor's Parcel Description
(Not to be used as a legal description)
SECT,TWN,RNG:10-7-88 DESC: TR IN
LOT 10 BK:0426 PG:0254 BK:1479
PG:597 RECPT:629195
Location
http://www.ga rcoact.com/assessor/parcel.asp?Pa rcel N um ber-239310400006 10/8/2009
Parcel Detail Page 2 014
Section
10
Township
7
Range
88
2009 Property Tax Valuation information
Additional Value Detail
Most Recent Sale
Sale Date:
Sale Price:
Additional Sales Detail
Basic Building Characteristics
Number of Residential Buildings:
Actual Value
Assessed Value
Land:
300,000
23,880
Improvements:
1,039,030
82,710
Total:
1,339,030 106,590
Additional Value Detail
Most Recent Sale
Sale Date:
Sale Price:
Additional Sales Detail
Basic Building Characteristics
Number of Residential Buildings:
2
Number ofComm/1nd
0
Buildings:
1
1
Residential Building Occurrence 1 Characteristics
L
OVERHANGING LIVE
NO/FOUND:
40
OVERHANGING LIVE
NO/FOUND:
63
2 STORY:
483
1 STORY:
813
2 STORY: 1502
TOTAL HEATED AREA:
2,886
ABSTRACT CODE:
SINGLE FAM.RES-IMPROVEMTS
ARCHITECTURAL STYLE:
2 -STORY
littp://www.garcoa ct.com /assessor/pa rceL asp?Pa rcel N u m ber=239310400006 10/8/2009
Parcel Detail Page 3 of4
EXTERIOR WALL:
WD SIDING
ROOF COVER:
COMP SHNGL
ROOF STRUCTURE:
r!DGE FRME
INTERIOR WALL
DRYWALL_
FLOOR:
CARPET
FLOOR:
5HT VINYL
HEATING FUEL:
GAS
HEATING TYPE:
FORCED AIR
STORIES:
STORIES 2.0
BATHS:
4
ROOMS:
8
UNITS: j
BEDROOMS:
4
YEAR BUILT:
1977
Additional Residential/Commercial Improvement Detail
Tax Information
Tax Year
Transaction Type
Amount
2008
Tax Payment: Whole
($5,016.52)
2008
Tax Amount $5,016.52
2007
Tax Payment: Whole
($5,041.44)
2007
Tax Amount
$5,041.44
2006
Tax Payment: Whole
($4,108.00)
2006
Tax Amount
$4,108.00
2005
Tax Payment: whole
($4,125.84)
2005
Tax Amount
$4,125.84
2004
Tax Payment: Whole
($3,935.04)
2004
Tax Amount
$3,935.04
2003
Tax Payment: Whole
($3,308.24)
2003
Tax Amount
$3,308.24
2002
Tax Payment: Whole
($3,635.88)
2002
Tax Amount
$3,635.88
11
http://www.ga rcoact.com/assessor/parcel.asp?Pa reel N u tuber -239310400006 10/8/2009
Parcel Detail
1 2001
2001
2000
2000
1999
1999
1 Tax Payment: Whole 1?
Tax Amount
Tax Payment: Whole
Tax Amount
Tax Payment: Whole
Tax Amount
Mill Levy Revenues Detail
($3,656.02'.1
$3,656.02
($3,503.28)
$3,503.28
($3,455.68)
$3,455.68
Page 4 of 4
To of Page
Assessor Database Search Options 1 Treasurer Database Search Options
Clerk & Recorder Database Search Options
Garfield County Home Page
The Garfield County Assessor and Treasurer's Offices make every effort to collect and maintain
accurate data. However, Good Turns Software and the Garfield County Assessor and Treasurer's
Offices are unable to warrant any of the information herein contained.
Copyright ® 2005 - 2008 Good Turns Software. All Rights Reserved.
Database & Web Design by Good Turas Software.
h-ttp: //www. ga rcoa ct. ca m/assessor/pa rce 1.a sp? Pa rce l N u m ber=239310400006 10/8/2009
WHIPPLE & BREWSTER
ASPEN NEW YORK
TRANSMITTAL FORM
To:
efri 51444
Date:
/0 ' tot 0
From'
c110 rO
(4
Project:
35/3 j2 //3
Subject: ,-cam S.S c !` l 13u1 h vt
3
Sent via: E Fax CI U.S. Mail E Email ' Hand delivered
Memo:
A +kc,/ie wadi SeGe1-11vo
A4) surpiew,efrt a I cAik,kt/1:_S
aS 1\e tt) e 1/45fe
121 South Galena Street, Suite 203, Aspen, Colorado 81611, Phone 970-920-4428, Fax 970-920-0427
WHIPPLE & BREWSTER
CORPORATION
121 SOUTH GALENA STREET, SUITE 203
ASPEN , COLORADO 81611
PHONE 970-920-4428
ACCESSORY BUILDING
3313 CATTLE CREEK
COUNTY ROAD 113
BE -KEPT AT
NSPECTION
ONSTRUCTION
o J E
tis
z o
LI n
cik H
iet
Z m W 2 r5 XIIIco
F- mJ O t/a +Q m
PPROVED
FIELD CIPY
NO INSPECTION WITHOUT
THEsE PLANS ON STTIg
pege of
NOTE: Items not shown in sufficient clarity
or detail (IRC/IBC Section 1 D6.1.1) shall be.
subject to review during inspections.
DRAWING INDEX
0 IMPROVEMENT SURVEY
Al SITE PLAN
A2 FLOOR PLANS & SECTION & SCHEDULES
A3 ELEVATIONS
Si FOUNDATION & FRAMING PLANS
S2 SPECS & DETAILS
14)
to
V
0
3„60,£00O0N
LOT 10
W
Q
S83°1210111E 1323.011
2K` I� COVCRE115 SPR'+
rox PTJ) L3Y tt,JkttW1 E 5''giN6r
nANC]PIP! LNE
\\\
green
house
r3ARPI 15.0t
r-
(1)
S 39°02'19"W 5 5.94
0 AD 113
SCALE 1"! 100'
(51
LEGAL DESCRIPTION
All that part of Lot 10, Sec 10, Tn 7 So., R 88 W of the 6th PM, lying Northerly of
the Cattle Creek Co., Rd.; EXCEPT that portion conveyed by Doc. #275873 in Book 491
at Page 306 described as follows: A parcel of land situated in Lot 10 of Sec 10,
Tn 7 So. R 88W of the 6th PM, Co. ofGarfield, St of Colorado lying Westerly of the
Lot Line between Lots 9 and 10 of said Section 10, said parcel of land is described
as follows: Beginning at a point on said Lot line whence the So Quarter Corner of
said Sec 10 bears: S 36°24'24" W. 2219.25 ft, thence S 65°45'57'1 W 106.51 ft along
the Northerly line of Co. Rd. 113; thence N 87°59'05" W. 428.20 ft along said
County Rd; thence S 81°19'55" W 194.44 ft along Said Co. Rd; Thence S
22°00'22" E. 30 ft. along said Co. Rd; thence S 17'1'38": W 109.98 ft a1on,§
said Co. Rd; thence N 79°57'54" W. 101.43 ft along said Co. Rd; thence N. 39 02119"
E. 55.94 ft. along the Easterly line of an existing 30 ft. roadway; thence N 20°20'00"
E. 242.50 ft. along said roadway; thence N. 02°00'00" E. 75.00 ft; thence S.
71°11'28" E. 271.75 ft; thence N. 76°00'00" E. 550 ft. to a point on the Lot Line
between Lots 9 and 10 of Section 10; thence S. 00°04'52" E. along said Lot line 300
feet, more or lean to the point of beginning.
Located in the County of Garfield, State of Colorado.
IMPROVEMENT SURVEY CERTIFICATE
I HEREBY CERTIFY TO GEORGE STEPHENSON WHIPPLE THAT ON
JULY 22, 2009 A SURVEY WAS PERFORMED BY ME ON THE PARCEL OF
LAND DESCRIBED HEREON. IMPROVEMENTS WERE FOUND TO BE ON
SAID PARCEL AS SHOWN ON THIS PLAT. ALL EASEMENTS,
ENCROACHMENTS AND RIGHTS -QF -WAY IN EVIDENCE OR KNOWN TO ME
ARE SHOWN. THIS SURVEY IS TRUE AND CORRECT TO THE BEST OF MY
KNOWLEDGE AND ELIEF.
B
1411i
Vra :worn
o4 2
S 14
. 1411
11'
1
IEMNT SURVEY PLAT
33 13 County Road 113
Carbondale, Colorado
Lines In Space Sydney Lincicome L.S. 14111
Box 121 Carbondale, Colorado el/0-963-3852
oc)r. 2009 Scale : 1"- 100'
(.w4o,q,. rQ i.oLo4ADo Liu!' You UJ!.' COMMENta AN+ LI(At• AC.ON HASLO uruN AN, OEGFCT iN THIS SURVEY
WITHIN r+IREF YVARS AFTER YOU FIRST DISCOVER SUCH DEFECT. IN NO EVENT. MAY ANY ACT/ON BASED UPON ANY
DEFECI IN PHIS SURVEY BE COmmENCED WORE THAN TEN YEARS FROM NE DATE OF 1NE CERTIFICATION SHOWN HEREON.
t.0 _
0.)
op
.0.
83'12 '01T
1323.01'
.. .. ....... .... ..... .
•
PROPERTY LINE
THRESHHOLO ELFV. 1013.00'
, ..... .....
.................
............
.......
......
.0.pp .................................... •••P ............ ....
IDDB
1.4
BARN
1.4
.................
.......
......
.. .
Ev.1002.J3'
....................... Pp. ................
4121 ............ ... ....................
1006
1004
OVERHANG
......... , .................... . .. 1002
__------
1002
99B
GARAGE/
STUDIO
'"•-••••
26
996
ED AREA
LP TA
WALK
N
GREENHOUSE
.99
4-2
990
ROCK WALL
98f1
WAL K
0
BENCHMARK : THRESHHOLD
ASSLMED R FV. 1000.00'
2.5
TWO-STORY FRAME HOUSE
gr
13.7.
GP7EN
alldriezetall
LINES IN SPACE
LAND SURVEYS
FLAGPOLE
ELEV. 1000.14'
IMPROVEMENT SURVEY CERTIFICATE
1 HEREBY CERTIFY THAT ON JULY 22, 2009 A SURVEY WAS PERFORMED BY ME ON THE PARCEL or LAND
DESCRIBED HEREON. A TWO-STORY FRAME HOUSE WAS FOUND TO BE ON SAID PARCEL AS SHOO ON THIS
PLAT. ALL EASEMENTS. ENCROACHMENTS AND RIGHTS-OF-WAY IN EVIDENCE OR KNOWN TO ME ARE SHOWN.
THIS SURVEY S TRUE AND CORRECT T THE BEST OF MY KNOWLEDGE AND BELIEF.
BY'
SYDNE, L CIC
P.L.S. 14111
3NI7 kit:13c1Md
2
rv;
W+ E
melowir%
0 KY W W 40.
SCALE: 1"m2O'
CONTOUR INTERVAL: 2'-O"
LEGEND AND NOTES
1 FOUND REBAR & CAP MARKED PLS 141 FI
A TRAVERSE POINT: SET SPIKE
0 POWER POLE
CID WELL
*-- FENCE LINE
EDGE OF ROAD
PINON TREE
SPRUCE TREE
JUNIPER TREE
SITE ELEVATION IS 5500 FEET.
WIOFISE
IMPROVEMENT SURVEY PLAT
3313 COUNTY ROAD 113
CARBONDALE, COLORADO
BY.. LINES IN SPACE
SYDNEY LINCICOME ( L.5 /4 / I I J
67 GLENWOOD A VE CARBONDAL E CO 970-963-3852
IPAGE 2 OF 2
DATE: 10/0//09 SCALE: I- - X' JOB NO.: 09-13A
WIOFISE
c?
98
000
EXISTING
GRAVEL DRiVE
992
PROPOSED
DWELLING UNIT
996
994
V. 1002.13'
PROPOSED
TWO - STORY
ACCESSORY
BUILDING
F.F. 100-0 =-
SITE
SITE 999.0.0
998
........ 1006
S 8311'011
1313.01'
1008
1002
ELEV. 1000.14'
998
PRO
I.S.D.S.
BARN
1004
996
988
9?
1002
334
W+E
0 10' 20' 30' 40'
SCALE: 1"=20'
CONTOUR INTERVAL: 2'-O"
PROPERTY LINE
EXISTING
GRAVEL DRIVE
10j<,
i
SITE ELEVATION IS 6600 FEET
LEGEND A\D NOTES
• FOUND REBAR Sc CAP MARKED PLS 14111
• TRAVERSE POINT: SET SPIKE
O POWER POLE
Qw WELL
-- FENCE UNE
EDGE OF ROAD
3NI1 K[dBd02hd
NEW
JALEN
IOLOR
ACCESSARY
BUILDING
3313
COUNTY
ROAD
113
GLENWOOD SPRINGS
COLORADO
ISSUE:
PERMIT 6 OCT 09
SHEET:
Al
NEW
8x8
WOOD
26'
EXISTING
SLAB
GARAGE
T.O. SLAB
100'-0"= 999.0
f 'RATED D.W. .`
WALL AND CEILING
9-0x7.O I
20 MIN
EXISTING
SLAB
STORAGE
NEW
CONCRETE
3-0
HANDRAIL
PER U.B.C.
LIP
2
3.46"
15R
7.33
13'-8"
J
12'-4"
POSTS
AND
FOOTINGS
LOWER LEVEL Ai
1/4"= V-0"
NORTH
N
ORA
/
T.O. PLY
T.O. SLAB =100'-0"
D.W. -
CEILING
SIZE
TYPE
5$
W
RAT:
LL
•
FIXED CASEMENT
SLV
1 G
3648 3672
FIXED CASEMENT
T.O. SLAB =100'-0"
D.W. -
CEILING
3E
EXISTING
SLAB AND FOUNDATION
SECTION
/41w1+ _ -0
2'
262 SF LOWER LEVEL
676 SF UPPER LEVEL
938 SF TOTAL STORAGE
49 SF CRAWL SPACE
301 SF GARAGE
55 SF COVERED
L�
26'
/
/
T
\ 1 /
STOFAGE /
\ /
\ /
\
/
/
/ \ T.O. PLY
/ \ "Pr 309'-2"
8J
/
71
\ 38` NGT..
WAIL ... �•
\w 1 CAP
1
11'-5"
UPPER LEVEL
1/:/4"=.
0"
0
WINDOW SCHEDULE
HANDRAIL
PER U.B.C.
NORTH
SYMBOL
SIZE
TYPE
QUANTITY
A
3672 3696 3672
FIXED CASEMENT
SLV
RA(
3648 3672
FIXED CASEMENT
< a
3E
EXISTING
SLAB AND FOUNDATION
SECTION
/41w1+ _ -0
2'
262 SF LOWER LEVEL
676 SF UPPER LEVEL
938 SF TOTAL STORAGE
49 SF CRAWL SPACE
301 SF GARAGE
55 SF COVERED
L�
26'
/
/
T
\ 1 /
STOFAGE /
\ /
\ /
\
/
/
/ \ T.O. PLY
/ \ "Pr 309'-2"
8J
/
71
\ 38` NGT..
WAIL ... �•
\w 1 CAP
1
11'-5"
UPPER LEVEL
1/:/4"=.
0"
0
WINDOW SCHEDULE
HANDRAIL
PER U.B.C.
NORTH
SYMBOL
SIZE
TYPE
QUANTITY
A
3672 3696 3672
FIXED CASEMENT
1
B
3648 3672
FIXED CASEMENT
1
B-1
3648 3672
CASEMENT
2
C
3648-2
FIXED CASEMENT i
2
C-1
3648-2
CASEMENT
1
0
3648
FIXED CASEMENT
3
E
3664
CASEMENT
1
F
3672 6
FIXED CASEMENT
1
DOOR SCHEDULE
SYMBOL
SIZE
TYPE
QUANTITY
1
3-0 x 7-0
BY OTHERS
1
NOTE:
- SEE ELEVATIONS FOR OPERATION INFORMATION.
▪ ALL GLASS WINDOWS AND DOORS ARE SIZED
AS MARVIN, CLAD UNITS.
- LOW 'E' INSULATED GLASS THRU OUT.
OZ C] to
z
W W a
z Q
ow'? z w Q
0 I.Q
GO 0
z co fl' w5�
J
0.
v
W Z !n W
APPROVED:
SUBJECT TO NOTE»
EXCEPT1ONS & INSPECTI0N4
GARFWLD COUNTY
BUILDING DEPARTMENT.
DatelO/WQ1 BY KO
FIELD COPY
NO INSPECTION WITHOUT'
THESE PLANS ON SITE '
page of
AMENDED PLAN
FOR 6 OCT 09 PERMIT SET.
ASPEN NEW YORK
121 SOUTH GALENA , SUITE
ASPEN , COLORADO 81611
970-920-4428 ,Fax 970-920-4427
ACCESSARY
BUILDING
3313
COUNTY
ROAD
113
GLENWOOD SPRINGS
COLORADO
ISSUE:
PERMIT 60CT 09
amended 20 OCT 09
SHEET:
A2
//
//
//
//\
/
T.O. PLY =
fl61-2"
LIVING ROO
rt
2'
GA
NEW
8x8
WOOD
26'
EXISTING
SLAB
GARAGE
T.O. SLAB
100'-0"= 999.0
%“RATED D.W.
WALL AND CEILING
9-0 x 7-0
, . ,
� NEW
CONCRETE
3-0
EXISTING
SLAB
SITTING
24
FOYER
HANDRAIL
PER U.B.C. 1
UP
15R
.3
3' 6"
13'-8"
t2'-4"
POSTS
AND
FOOTINGS
LOWER LEVEL
"= ,1, 1 J
4
NORTH
%"RATE
WALL AN
GE
D
T.O. SLAB =100'-0'
D.W.
CEILING
Kt
SITTIN
EXISTING '
SLAB AND FOUNDATION
SECTION
n__ v , 0"
4
fsif TW2u1`'(
/Vs I s
262 SF LOWER LEVEL
676 SF UPPER LEVEL
938 SF TOTAL LIVING
49 SF CRAWL SPACE
301 SF GARAGE
55 SF COVERED
26'
a ! o
w,o
EXHAUST
FAN - TYP.
2A
OYi'tiLt (9h(((
/
/
LIVING
/
BEDROOM k
4 /I
/
/
ROOM
T.O. PLY
109'-2"
\36" HGT.
WALL
\w / CAP
3-0
ommlik
HANDRAIL
PER U.B.C.
W$NDOW
SEAT
11'-5"
/1
0
e
N
o
UPPER LEVEL 0
/4"=
WINDOW SCHEDULE
NORTH
SYMBOL
SIZE
TYPE
QUANTITY
A
3672 3696 3672
FIXED CASEMENT
1
B
3648 3672
FIXED CASEMENT
1
B-1
3648 3672
CASEMENT
2
C
3648-2
FIXED CASEMENT
2
C-1
3648-2
CASEMENT
1
D
3648
FIXED CASEMENT
3
E
3664
CASEMENT
1
F
3672
FIXED CASEMENT
1
DOOR SCHEDULE
SYMBOL
SIZE
TYPE
QUANTITY
1
3-0 x 7-0
BY OTHERS
1
NOTE:
- SEE ELEVATIONS FOR OPERATION INFORMATION.
- ALL GLASS WINDOWS AND DOORS ARE SIZED
AS MARVIN, CLAD UNITS.
- LOW 'E' INSULATED GLASS THRU OUT.
J
STEW
:ALEN
:OLOR
ACCESSARY
BUILDING
3313
COUNTY
ROAD
113
GLENWOOD SPRINGS
COLORADO
ISSUE:
PERMIT 6 OCT 09
SHEET:
A2
J
STONE
VENEER
w/CAP
T.c
PL'tir 109'4"
_'-
EXISTING GRADE
T.©. MONC. =100" V
EXISTING
FOUNDATION --
0
NORTH ELEVATION
3/411= 11 O"
z'
�_- 8x8 8x8
POST
NEW
PIERS
T0.PI_
1
STONE
VENEER
w/CAP
EXISTING
FOUNDATION
SOUTH ELEVATION
Y4"
1 1_011
BUILDING HEIGHT
EXISTING GRADE
POST - _.�.-
STONE
VENEER
w/CAP
--�
NEW
PIERS
r
L
7-0
=f _ J
- -` -�_- ;--
-
EXISTING -
-
FOUNDATION
WEST ELEVATION
/411- 11-0"
STONE
VENEER
w/CAP
EXISTING
FOUNDATION -
T.O. SLAB 4100'-O
EAST ELEVATION
411 _ 1 1 o 11
�- I��f
==7
EXISTING GRADE
ASPEN NEW YORK
121 SOUTH GALENA , SUITE
ASPEN , COLORADO 81611
970-920-4428 ,Fax 970-920-4427
ACCESSARY
BUILDING
3313
COUNTY
ROAD
113
GLENWOOD SPRINGS
COLORADO
ISSUE:
PERMIT 6 OCT 09
SHEET:
A3
2'-0"/
2x10 LOOKOUTS 0 24" 0.C.
W/ LUS210 HANGER, TYP.
2-2x8
a
cn
M
RS
RA RS
12114
v
N
2x10 LOOKOUTS 0 24" 0.C.
W/ LUS210 HANGER, TYP.
STRAP POP—OUT WALL
TO OUTLOOKERS/ TOP PLATE
W/ (2) MSTA24 EA. SIDE
ROOF FRAMING PLAN
SCALE: 1 /4" = 1'-0"
STRUCTURAL NOTES:
1. RAFTERS ARE 11 7/8" TV/ 210 0 24" O.C. W/ LSSUI2.1 HANGERS, TYP. U.N.O.
J�
J
CO
00
x
x
Kf
D.T.
V i r ITT2.1 /11.88
3-2x8
3-2x8
DF#1
L
UPPER LEVEL FRAMING PLAN
SCALE: 1 /4" =
STRUCTURAL NOTE '
1. FLOOR DESIG DOES NOT ALLOW FOR CONCRE OR GYPCRETE TOPPING.
COLUMN LEGEND
n
1. • DENOTES COLUMN BELOW.
2. 0 DENOTES COLUMN ABOVE OR TRANSFERED THIS LEVEL
3. ® DENOTES CONTINUOUS COLUMN.
4. K.P. = KING POST
5. D.T. = DOUBLE TRIMMERS
6. PROVIDE ENOUGH STUDS TO MATCH WIDTH OF BEAM ABOVE.
7. ALL COLUMNS SHOWN ARE 2-2x6's UNLESS NOTED AS FOLLOWS:
WOOD PARALLAM. PSL ,SEL
® - 3-2x6 Q — 31/2x31/2 ® — HSS3x3x1/4
® — 4-2x6 ® — 31/2x51/4 8 — HSS 4x4x1/4
© - 5-2x6 Q— 5 1/4 x 5 1/4 gi — HSS 4 x 4 x 3/8
O — 3-2x4 ®— 5 1/4 x 7 O — HSS 4 x 4 x 1/2
® — 4-2x4 ® — HSS 5 x 5 x 1/4
0 - 5-2x4 0 - HSS 5 x 5 x 3/8
© - 6x6POST O - HSS5x5x1/2
® - 8 x B POST ®- HSS 6 x 4 x 1 /4
26'-0"
•
N
N
co
CO
I
O r r �o
I-- EXISTING FOUNDATION
8"fit,
1'-9 1/2"
Q GARAGE
TSO _SLAB_
4"
9'-0"
12"0 PIER. TYP.
YJ, 8"
•
12'-4"
26'-0"
FOUNDATION PLAN
SCALE: 1/4" = 1'-0"
FOOTING SCHEDULE
/Ef'4
Cie
J{i
N
�%
ti
REINFORCING. EA. WAY
(TING: A)
2'-0" SQ.
10"
#4 0 8" O.C.
_ 6 3/4" x 24" G.L
2'-6" 50.
S2
#4 0 11" O.C.
?`7
A eO
s !L.
A
N
2-14" ML
XI V
Q,
cn
4-
Q'
v
N
2x10 LOOKOUTS 0 24" 0.C.
W/ LUS210 HANGER, TYP.
STRAP POP—OUT WALL
TO OUTLOOKERS/ TOP PLATE
W/ (2) MSTA24 EA. SIDE
ROOF FRAMING PLAN
SCALE: 1 /4" = 1'-0"
STRUCTURAL NOTES:
1. RAFTERS ARE 11 7/8" TV/ 210 0 24" O.C. W/ LSSUI2.1 HANGERS, TYP. U.N.O.
J�
J
CO
00
x
x
Kf
D.T.
V i r ITT2.1 /11.88
3-2x8
3-2x8
DF#1
L
UPPER LEVEL FRAMING PLAN
SCALE: 1 /4" =
STRUCTURAL NOTE '
1. FLOOR DESIG DOES NOT ALLOW FOR CONCRE OR GYPCRETE TOPPING.
COLUMN LEGEND
n
1. • DENOTES COLUMN BELOW.
2. 0 DENOTES COLUMN ABOVE OR TRANSFERED THIS LEVEL
3. ® DENOTES CONTINUOUS COLUMN.
4. K.P. = KING POST
5. D.T. = DOUBLE TRIMMERS
6. PROVIDE ENOUGH STUDS TO MATCH WIDTH OF BEAM ABOVE.
7. ALL COLUMNS SHOWN ARE 2-2x6's UNLESS NOTED AS FOLLOWS:
WOOD PARALLAM. PSL ,SEL
® - 3-2x6 Q — 31/2x31/2 ® — HSS3x3x1/4
® — 4-2x6 ® — 31/2x51/4 8 — HSS 4x4x1/4
© - 5-2x6 Q— 5 1/4 x 5 1/4 gi — HSS 4 x 4 x 3/8
O — 3-2x4 ®— 5 1/4 x 7 O — HSS 4 x 4 x 1/2
® — 4-2x4 ® — HSS 5 x 5 x 1/4
0 - 5-2x4 0 - HSS 5 x 5 x 3/8
© - 6x6POST O - HSS5x5x1/2
® - 8 x B POST ®- HSS 6 x 4 x 1 /4
26'-0"
•
N
N
co
CO
I
O r r �o
I-- EXISTING FOUNDATION
8"fit,
1'-9 1/2"
Q GARAGE
TSO _SLAB_
4"
9'-0"
12"0 PIER. TYP.
YJ, 8"
•
12'-4"
26'-0"
FOUNDATION PLAN
SCALE: 1/4" = 1'-0"
FOOTING SCHEDULE
DESIG.
SIZE
THICK.
REINFORCING. EA. WAY
(TING: A)
2'-0" SQ.
10"
#4 0 8" O.C.
(FTNG: B)
2'-6" 50.
10"
#4 0 11" O.C.
(FTNG: C)
3'-0" SO.
10"
#5 0 14" O.C.
(FTNG: D)
3'-6" SQ.
10"
#5 0 12" O.C.
REVISIONS
(FTNG: E)
4'-0" SQ.
10"
#5 0 12" O.C.
(FTNG: F)
4'-6" SQ.
12"
#5 0 12" O.C.
TING: G)
5'-0" SQ.
12"
#5 0 12" O.C.
PERMIT ONLY
}LATCHING LEGEND
DENOTES OVER -FRAMING
DENOTES BEARING WALL BELOW
DENOTES STONE VENEER ABOVE
C:\Documents and Settings\Ernie Kollar\My Documents\Projects\2009\0937 Cattle Creek - Whipple\Guest House\ModeLdwg, 9/28/2009 9:14:22 AM
C..
y'
ERNEST KOLLAR
ENGINEERS, INC.
320 MAIN STREET, SUITE 203
Carbondale, CO 81623
(970) 983-3223
FAX (970) 963-9395
.;
.
...
gh, ..
.Y 'J• C,y ., .„ : »t
.t,
Y `\
L.
Ho
rTY ]
RING
REVISIONS
JOB NUMBER
0937
DATE
9-28-09
PERMIT ONLY
DRAWN BY
EPK
CHECKED BY
SHEET
NUMBER
C:\Documents and Settings\Ernie Kollar\My Documents\Projects\2009\0937 Cattle Creek - Whipple\Guest House\ModeLdwg, 9/28/2009 9:14:22 AM
STRUCTURAL GENERAL NOTES & SPECIFICATIONS
DESIGN DATA:
A. DESIGN LIVE i_OAOS
1. Basic Roof Snow
2. Residential Roars
3. Decks
8. DESIGN CODES
International Residential Code, (IRC), 2003
with the International Building Code, (IBC), 2003 for Special Inspection
American Concrete institute Building Code (ACI 318-99)
American Institute of Steel Construction, Manual of Steel Construction (AiSC 9th Edition)
American Institute of Timber Construction, Timber Construction Manual (AITC 5th Edition)
National Design Specifications for Wood Construction (NDS 2001)
WHIPPLE & BREWSTER GUEST HOUSE
40 PSF
40 PSF
40 PSF
4. Garage 50 PSF
5. Wind 90 mph, Exposure
6. Seismic Design Category
B
C
GENERAL:
1. Any changes to the contract drawings shall be submitted to the structural engineer for approval.
2. Ali dimensions and details on structural drawings shall be verified against the architectural drawings and any
discrepancies shall be brought to the attention of the architect prior to fobricotion or construction. Details on
the structural drawings are typical. DO NOT SCALE DRAWINGS.
3. Ali openings through the structural system shall be approved by the Engineer.
4. Contractor shah provide all necessory temporary bracing, shoring, guying or other means to prevent excessive
stresses and to hold the structural elements in place during construction.
5. The controct structural drawings and specifications represent the finished structure. They do not Indicate
the method of construction. The contractor shall provide all measures necessary to protect the structure during
construction. Such measures shall include, but are not limited to bracing, shoring for loads due to construction
equipment and protection of existing structures. Observation visits to the site by the structural engineer shall
not include inspection of the above items nor will the structural engineer be responsible for the contractor's
means, methods, techniques, sequences for procedure of construction, or the safety precautions and programs
incident there to.
6. Options are for the convenience of the contractor. He shall be responsible for all changes necessary if he
chooses an option and shall coordinate all details. The cost of additional engineering work necessitated by
selection of an option shall be borne by the contractor.
7. Arty engineering design provided by others and submitted for review shall bear the seal and signature of an
engineer registered in Colorado.
8. Dimensions an the structural drawings are exact with the exception of masonry and sawn lumber dimensions
which are nominal. Verify ail dimensions with the architectural drawings.
l arenotshownornotthesecontractor shall
9. Where required construction details sho noted on plans the co t actor notify the
engineer and the engineer shall provide sufficient details for the work to proceed.
10. Construction materials shall be spread out if placed on frarned construction. Load shall not exceed the
design live load per square foot.
11 Shop drawings shall be submitted to the architect for all structural items. The Engineers review le intended
only as on aid to the contractor for obtaining correct shop drawings. Responsibility for correctness shalt rest
with the contractor. The contractor shall review all shop drawings prior to submittal. Items not in accordance
with the contract documents snail be flogged upon his review. The shop drawings do not replace the original
contract drawings. it is the contractors responsibility to make sure items are constructed to the original
drawings. The adequacy of engineering designs and layout performed by others rests with the designing or
submitting authority.
FOUNDATION:
A. GENERAL
The foundation design was based on the following assumed parameters:
Maximum allowable bearing pressure - --27G00 psf
Minimurn required dead load pressure - 0 psf
Lateral soil pressure - Active 45 pcf
- Passive 300 pcf
The actual soil condition sholl be investigated and the above parorneters shall be verified by a Solis Engineer,
registered in the State of Colorado, prior to construction of the foundation. if there are any discrepancies with
the above assumptions, then the foundation shall be re -designed.
B. EXCAVATION
1. Contractor shall provide all necessary sheeting, shoring and bracing where required to properly and safely
complete the work.
2. Avoid excessive wetting or drying of the foundation excavation during construction. Keep excavations
reasonably free of water at all time and completely free of water during placement of concrete.
C. BEARING REQUIREMENTS
1. Footings shall bear on natural undisturbed soil below the frost depth required by the applicable building
code. Any discrepancies with the footing elevations shown on the plans shall be brought to the attention of the
engineer.
2. Building shall be founded on continuous concrete spread footings placed on undisturbed natural soil.
D. GENERAL REQUIREMENTS
1. Center foundations under columns and walls unless noted otherwise.
2. Provide foundation ventilation in crawl space areas as required by the I.R.C.
3. Backfin on watts with fill on both sides shall be compacted in equal lifts each side of wall. Walls backfified
on one side only shall have ail supporting slabs, permanent framing or temporary bracing in place prior to
piocement of the backfill (unless noted otherwise on pians).
CONCRETE:
A. CONCRETE REQUIREMENTS
Concrete hos been designed and shall be constructed in accordance with the latest editions of the
American Concrete institute Building Code, ACI 318 and Specifications for Structural Concrete for Buildings, ACF
301. Provide hot or cold weather protection per ACI 305 & 306.
1. Concrete shall hove a minimum compressive strength at 28 days of:
Walls & footings 3000 psi
Slobs 3000 psi
2. Provide Type iI cement throughout with 4% air entrainment.
3. Mechanically vibrate concrete,
4. No admixtures shall be used without approval by the engineer.
5. Addition of water to the batch material for insufficient slump is not permitted.
6. Do not place pipes, ducts or chases in the structural concrete without the approval of the engineer.
7. Thoroughly clean all case and construction joints prior to placing concrete in adjacent pour.
8. Concrete shall not be In contact with aluminum.
B. REINFORCING
Detailing, fabrication, and erection of reinforcing steel bars shall comply with the ACI Manual of Standard
Practice far Detailing Reinforced Concrete Structures ACI 315.
1. Reinforcing bars shall be ASTM A615 -Grade 60.
2. Welded wire fabric shall conform to ASTM A185. Furnish in flat sheets only.
3. Concrete protection for reinforcement:
Cast against and permanently exposed to earth 3 in.
Exposed to earth or weather #6-#18 bar 2 in.
#3-#5 bar 1 1/2 in.
Not exposed to earth or weather slabs & walls 3/4 in.
beams & cols1 1/2 in.
4. Reinforcing lap splices shall be a minimum of 36 bar diameters unless noted otherwise. Lap wire fabric
reinforcement one full mesh plus 2" at sides and ends and wire together.
5. Splices in horizontal beams and walls shall occur at midspan for top bars and over supports for bottom
bare.
6. Discontinue one-half of horizontal steel across construction/control joints.
7. Provide corner bars of equal size and spacing around all corners.
6. Provide 2-#5 bars with a minimum of 2'-O" projection beyond the sides of all openings In Ovalis, beams and
slabs. Provide 1-#5 x 4'-0" diagonally at all re-entrant corners of slabs.
9. Provide accessories necessary to properly support reinforcing at the positions shown on the plans.
10. Reinforcing spacings are maximum on center and all reinforcing is continuous, unless noted otherwise.
C. SLABS
1. Provide control joints at 12'-0" max. spacing or as shown on the plans.
2. Provide minimum 4" compacted gravel under floor slab on grade. The material shall consist of minus 2 -inch
aggregate w/ less than 50% passing the No. 4 sieve and less than 2% passing the No. 200 sieve.
MASONRY:
A. CONCRETE MASONRY UNITS (CMUs)
1. All CMUs shall conform to ASTM 090.
2. CMUs used below grade and all exterior walls shall be Grade "N", Type 1 and interior concrete masonry units
not exposed to weather or earth may be Grade "N" or Grade "S Type 1.
3. Ali masonry shall attain 1,500 psi compressive strength (fm) in 28 days. Special Inspection required.
B. GROUT
All mortar for exterior walls and interior bearing walls shall conform to ASTM C270, Type S.
2. Grout for masonry bond beams and pilasters shall be mode with stone aggregate and shall attoin 3,000 psi
compressive strength in 28 days.
3. Grout lifts shall not exceed 4'-O" unless clean outs are provided. if cleonouts are provided then grout lifts
shall not exceed 8'-O".
C. REINFORCING
1. Reinforcing bars shall conform to ASTM A615 -76a, Grade 60.
2. Horizontal reinforcing shall be #5 at 48" plus joint reinforcement (standard truss type) spaced at 16" on
center except as noted. A bond beam shall be installed at floor levels, roof levels s and top of parapet walls.
Horizontal reinforcernent to be placed In bond beam units, grouted solid. Vertical reinforcing as shown on plans
shall extend full height of the wall in grouted cells, U.N.O.
3. Provide 1-j5 in grouted cell at all corners, ends of walls, each side of openings and both sides of control
Joints.
4. Lap bar splices 36 bar diameters. At corners and intersections, make horizontal bars continuous or provide
matching corner bars.
0. GENERAL REQUIREMENTS
1. Fill all voids and grout cells solid far a distance of 32" below and 12" each side of all beam reactions or
other concentroted loads unless noted otherwise on plans.
2. Provide vertical control joints in all masonry wall at 35'-0" maximum spacing as located on the architectural
drawings.
3. Provide masonry lintel bond beams as follows:
a, Spans not exceeding 4'-8"; provide 8" deep bearn reinforced with 2-#5 bars continuous in
bottom beam,
b. Spans not exceeding 12'-O"; provide 16" deep beam with 2-#5 bars continuous at bottom of
beam and 1-#5 bar continuous at top of beam. Install #3 stirrups (single leg) at 6" on center
horizontal spacing. Bottom reinforcing shall be within 3" of the bottom of the beam.
STRUCTURAL STEEL:
A. STRUCTURAL STEEL
Structural steel shall be detailed, fabricated and erected in accordance with latest provisions of the AISC
Manual of 'Steel Construction and MSC Code of Standard Practice. Use welders meeting the requirements
of the AWS Standard Qualification Procedure. Comply with AWS 01.1 Structural Welding Code.
1. All steel shall conform to ASTM A36 except beams shall be ASTM A992 Grade 50 and tube columns which
shall conform to ASTM A500 (GR. B) and pipe shapes which shall conform to ASTM A53 (Or. 0).
2. Bolts shall conform to ASTM A325N. Anchor bolts shall conform to ASTM A307. Bolt size shall be 3/4"
diameter unless noted otherwise. Installation shall be in accordance with AISC Specifications for Structural Joints
Using ASTM A325 or A490 Bolts. 1978.
3. All welds shall be made with E7OXX electrodes.
4. Prime all steel with approved primer paint to exposed bolts, welds, and abraded shop paint areas.
5. All column base plates shall have 1" minimum grout to provide continuous bearing.
B. GROUT AND ANCHOR BOLTS
1. Dry pack or grout shall be shrink resistant Embeco 153 or equivalent.
2. Expansion bolts shall be Simpson "Wedge -All" or approved wedge type. installed in accordance with the
manufacturer's requirements.
3. Headed anchor studs (H.D.A.S.) shall be attached to structural steel with equipment approved by the stud
manufacturer according to the stud manufacturer's recommendations. 4. Anchor bolts embedded in concrete
shall be placed with setting templates. 5. Location and coordination of anchor bolt placement shall be the
responsibility of the steel fabricator. Steel fabricator shall supply anchor bolt setting plan.
C. STEEL CONNECTIONS
1. Provide bolted connections for steel beams per Part 4 and Part 5 of the AISC Manual of Steel. Construction.
Except where otherwise shown, provide connections to support loads equal to one-half the total uniform load
copocity of the member.
2. A minimum of two bolts shall be used for oil connections. Size and grade shall be determined by the
fabricator.
STRUCTURAL WOOD FRAMING:
A. DIMENSIONAL LUMBER
All wood members shall be as described in the 2001 edition of the "National design Specifications for Woad
Construction" by the National Forest Products Association and the WWPAW.
1. Unless otherwise noted on the drawings, wood framing members shall b Douglas Fir/Larch Grade #2 or
better. Redwood members shall be construction grade.
2. Sizes shown are nominal, except when noted as RC (Rough Cut) they ore full dimensions.
3. All wood members attached to concrete or masonry shall be redwood or pressure treated lumber.
4. Block all joists and rafters per the I.R.C.
B. FASTENERS AND CONNECTORS
Alternate fasteners and connectors to those listed below, which have i.0.8.0. approval, may be used with
approval by the Engineer.
1, Connectors shown on the plans are manufactured by the Simpson Strong -Tie Company, Inc. Connectors
by other manufactures shall be deemed as equivalent if their rated capacity is equal to or greater than that
of the connector specified. Follow manufacturer's recommendations for installation of connectors.
2. All timber nailing and connections shall conform to the IRC and ALTO.
3. Bolts for wood member connections shall be 3/4" diameter, AST}A A307 with a minimum 1 1/2" washer
at each end (unless noted otherwlse).
4. Self --drilling fasteners for the attachment to structural steel shall be "Teks" fasteners as manufactured
by Buildex.
C. PLYWOOD SHEATHING
Plywood sheathing for roofs, floors and exterior shear walls shall be APA Grade -Trademarked C -D, Exposure
1, unless otherwise noted.
1. Roof Diaphragms (240 pif) shall be 5/8", APA rated sheathing, 40/20 place with 8'-0" dimension
perpendicular to the joist, rafter or truss span. End joists shall be staggered. Attach plywood at edges with
8d nails at 6" Q.C. and at intermediate supports with 8d nails at 12" O.C.
2. Floor Diaphragms (250 pif) shall be 3/4", APA rated Sturdi-I-Floor, 24 D.C. place with 8'-O" dimension
perpendicular to the joist span. End joints shall be staggered. Attach plywood with APA glue and at edges
nail with 8d nails at 6" 0.C. and at intermediate supports with 8d nails at 10" O.C. Sheathing shall be T&G.
3. Shear Wall Diaphragms (180 pif, 380 pif wind) shall be 1/2", APA rated sheathing, 24/0 with 8"-0"
vertical. dimension End joints shall be staggered.Studs shall be 16" O.C. Attach plywood at edges with
1Od nails at 4" 0.C. and at Intermediate supports with 8d nails at
5 0.C. Sheath all exterior wells full
Il
height with 1/2" plywood. At all corners, min. 4'-O" each direction, block plywood edges and nail as noted
above.
D. GLUE LAMINATED BEAMS Laminated member shall be designed and fabricated in accordance with "The
Standard Specifications for the Design and Fabrication of Structural Glue Laminated Lumber" published by the
AITC and the appropriate Lumber Producers' Association.
1. Use exterior glue for all exposed laminoted members.
2. All members exposed to weather shall receive one coat of end sealer at trimmed ends. Seal all exposed
surfaces with sealer coat as soon as practical after erection.
3. Appearance grade shall be in accordance with the architectural drawings.
4. If beam is cantilevered and the cantilever is greater than one-third of the back span, install beam "TOP"
down.
5. Allowable unit stresses for dry conditions of use required shall be as follows:
Members stressed principally in bending such as beams & girders (AITC 24F -V4) unless otherwise
noted on drawings.
Fb=2400 psi Fv=165 psi Fc(perp)=650 psi E=1.8E6 psi
Members stressed principally In compression or tension such as columns & truss members (AITC
24F -V8) Unless otherwise noted on drawings.
Fc(paraliet)-1650 psi E=1.6E6 psi
E. MICRO -LAM BEAMS
Micro -laminated members shall be designed and fabricatedin accordance with the "National Research Board"
and the "National Design Specifications for Wood".
1. Allowable unit stresses for dry conditions of use required shall be as follows:
Fb-'2600 psi Fv=285 psi Fc(perp)= 750 psi E' -1.8E6 psi
2. Install micro -laminated members in accordance with the manufacturer's recommendation.
3. Holes, cuts, or notches not previously approved by the engineer or the manufacturer shall not be mode.
4. Micro --laminated lumber is marked on the drawings as "ML" and shall be 1 3/4" wide, unless noted
otherwise.
F. FABRICATED WOOD JOISTS (i -Series)
I -series fabricated joists with structural wood flanges and plywood webs called for on the drawings (TJI/210.
TJI/360, TJI/560)) are as manufactured by the Trus -Joist Corp..Joists by other manufacturers may be used
if the depth and deflection is equal to or less than that of the joist specified for the particular span and
spacing and when authorized by the Architect/Engineer.
1. Fabricated wood joists shall be in accordance with the manufacturer's recommendations.
2. Supply all plates, blocking, bridging, bracing, stiffeners and other related items as recommended by the
manufacturer.
G. TIMBERSTRAND INSULATED HEADERS
insulated headers sholl be Tlmberstrand LSL 1.5E Insulated Headers as manufacturerd by Trus Joist. The
width shall be 5 1/2 inches with depth as shown on plans.
4" CONC. SLAB
.N
0"
3-#5xVERT.
CONST. JT.
12"e PIER
8x8 POST
PL 1/4x3x10" (KNIFE)
W/ 2-1/2"0 BOLTS
PL 1/4x7x7
w/ 2-1/2"x6" H.A.S.
#9 WIRE TIES
0 10" 0.0.
3-#5x LVERT.
10"
1 1/2"
CLR.
z
J
0
T.O. FTNG.
SEE PLAN
SEE PLAN
1
2-5/8"0 LAG
(8" MIN. EMBED.)
WOOD BEAM,
SEE PLAN
WOOD COL
2
PL 1/4
1/4
GL BEAM,
SEE PLAN
NNINk_
4-1/2"e x 4" LAGS
(B" MIN. EMBED.)
LVL VALLEY;
2 PLY
*IlLPL 3/8 (BETWEEN LVL PLIES)
w/ 3- 3/4"e BOLTS
LVL RIDGE;
2 PLY
2"
MIN.; (ALLOW FOR BOLT INSTALLATION)
3
INSIDE FACE
OF FRAMING
000 SHEATHING
1/2" PLYWOOD SHEATHING;
EXTEND TO INSIDE FACE OF
FRAMING
PLAN
14
E-+ W
z
Z z
320 MAIN STREET, SUITE 203
963-9395
-Ire' le el
m
1-41
w
0
0
tiv
r
c
H
H 124
cn4-112-1
(11ool
cy,.)12)
0
CrDI
Cr) 14
REVISIONS
JOB NUMBER
0937
DATE
9-28-09
PERMIT ONLY
DRAWN BY
EPK
CHECKED BY
SHEET NUMBER
S2
C:\Documents and Settings\Ernie Koilar\My Docunients\Projects\2049\O937 Cattle
4" FOAM INSULATION (SPRAYED)
R25.6
wivott-: .0•40„ aritourtie
Dio
•1Lfi1 4
4fr
Vit:,�4
�;,f1sly
fi
mu...:_;
f►�iif:_:
r 1404,
4Ab vow,
11%8 ENGINEERED
RAFTERS
R-19 BATT
INSULATION
w / VAPOR BARRIER
ROOF SHINGLES
BITUTHANE BUTYL RUBBER
5/8" OSB
2" x 10" OUT
LOOKERS
5/8" DRY WALL THRUOUT
EXCEPT WHEN PLANS CALL
FOR RATED DRYWALL.
117/9
ENGINEERED
JOISTS
ItZIM 2,
2 X 6 WALL
STUDS @
16" O.C.
3/4" SUBFLOOR T/G
GLUE AND NAIL
5/8" DRY WALL THRUOUT
EXCEPT WHEN PLANS CALL
FOR RATED DRYWALL.
DRIP EDGE
WOOD FASCIA (2 pc )
1" X 6" PINE SOFFIT
\� f� WOOD SIDING
EXISTING
CONC. SLAB
R-19 BATT
INSULATION
VAPOR BARRIER
2 X 6 WALL -----
STUDS @
16" O.C.
2X6
PLATE
2 X 6 TREATED
PLATE
SILL SEAL
fl
40
1
1§1
I =1
mam,41t 4
PAP
RIM BOARD
DBLE. 2 X 6 PLATE
1/2" OSB SHEATHING
- FLASHING
5"STONE VENEER
BITUTHANE
FLASHING
1
rife
EXISTING
CONC.
FOOTING
15# FELT
VAPOR BARRIER
ANGLE SUPPORT AT STONE
WITH APPLIED WATERPROOFING
EXISTING
8" C.M.U.
WALL SECTION
3/4" = 1'-0"
EXISTING
FINISH GRADE
SUPPLEMENTAL DRAWING
FOR 6 OCT 09 PERMIT SET.
NEW
:ALEN
-2OLOR
28 ,Fax 97
ACCESSARY
BUILDING
3313
COUNTY
ROAD
113
GLENWOOD SPRINGS
COLORADO
ISSUE:
PERMIT 12 OCT 09
SHEET:
A4