Loading...
HomeMy WebLinkAboutApplication- PermitGarfield County Building & Planning Department 108 8th Street Suite 401 Glenwood Springs, CO 81601 - Phone: (970)945-8212 Fax: (970)384-3470 Project Address Parcel No. 704 SKIPPER DR CARBONDALE, CO Permit NO. BLRE-9-11-2203 Permit Type: Residential Building Work Classification: Addition Permit Status: Active Issue Date: 9/29/2011 Expires: 03/27/2012 I Subdivision 239129305010 Section Township Range STIRLING RANCH PUD Owner Information Address Scott & Leah Powel & ODonell 350 madison AVE CO 10017 Phone Cell 212-920-2640 Contractor(s) Phone Primary Contractor Crystal Springs Builders (970)963-4584 Yes Proposed Construction / Details Interior remodel on a single family dwelling FEES DUE Fee Amount Plan Check Fee $671.42 Residential Building Fee $1,032.95 Total: $1,704.37 Valuation: Total Sq Feet: FEES PAID $ 106,500.00 0 Inv Total Paytype Amt Paid Amt Due Inv # BLRE-9-11-21395 $ 1,704.37 Check # 1016 Credit Card $944.42 $759.95 $ 0.00 Required Inspections: For Inspections call : 1(888)868-5306 Inspection IVR See Permit Record Building Department Copy Thursday, September 29, 2011 2 aat-fzltt 4r- —.1C)Z,1 it3,71 108 8th Street, Suite 401, Glenwood Springs, CO 81601 Ph:970-945-8212 F_x:970-384-3440 Inspection Line:888-868-5306 www.garfield-county.com BUILDING PERMIT APPLICATION SEP i 4 2011 p-5 1 Parcel No: (this information is available at the assessors office 970-945-9134) 23912.7305o/0 Lot No: Block No: Subd./ Exemptit5X:' I0 Sngu,.VRoza Pa P. 2 Job Address: (if an address has not been assigned, please provide CR, H74'Yor Street Name & City) or and legal description 7.9 $ s,Fippet Ione Ca-A*0/1 4/e , co 9/(.2 3 3 Owner: (properly, owner) orr 3‘.../.ice. 3 /EMI O'9ClNf&G Mailing Address: 350 A/44 4544 ave. Ay, 4y 70017 Ph: ,2a . 5z 0. 2 Lo Alt Ph: 4 Contractor: CRYSr#L 51 W65 guri-pii'S Mailing Address: 1000 A.1,'n sit car �rnh41 Co gU2-3 Ph: x970. 963 '/5gy 4,2044-3-74#3 Alt Ph: OCC Group- C 5 Manufactured home installer: Mailing Address: Ph: Lic #: 6 Architect: tj Emil '.- .gvrce $g,K Ale6TfGrf Mailing Address: yo ),ox 107 iasalil co 116.2.1 Ph: 770. 927. 0635 Alt Ph: 31-4'3696 7 Engineer: eow.SX l - »itF.t Mailing Address: (e.iv r,1.<1m 5d 0 nta; A xi ,suAr 3/0 Ph: 970. 7'3.9.0.3 Alt Ph: 8 Sq. Ft. of Building: Sq. Ft. or Acres of Lot: /.2. 9.2.4 aorta Height: No. of Floors: / 9 Use of Building: Residential ❑Commercial OOther Class of Work: [New Alteration ❑Addition ❑Repair ❑Demo ❑Move 10 Describe Worlyt J Fx•f6 SIP c!• New obits f U,:huluws. .I.' OrE Ln iotZp MF Uti trEt, o f 30111 op.' b{S A yK0?hltA, I )20,rrta ele t, I. f) t .. >,1 f A f 1 DElectric j*Other 11 Garage: .QAttached ❑Detached Septic: tt gISDS DCommunity Type of Heat: [Nat. Gas DPropane 12 Driveway Permit: Owners valuation of WWrk: ir/ 1 ` . ...L., Authority. This application for a Building Permit must be signed NOTICE by the Owner of the property, described above, or an authorized agent. If the signature below is not that of the Owner. a separate provided with this Application. proof of legal and adequate access to the property for purposes of inspections by the Building Department. (1) State Electrical Permit, (2) County ISDS Permit, (3) another permit required for use on the property identified above, e.g. State or Wastewater Discharge Permit. work authorized is not commenced within 180 days of the date of issuance and if work is suspended or abandoned for a period of 180 CERTIFICATION information contained above is true and correct. I understand that the Building Department accepts the Application, along with the plans behalf (submittals), based upon my certification as to accuracy. Application, a Building Permit will be issued granting permission to me, as Owner, to construct the structure(s) and facilities detailed on that 1 and my agents will comply with provisions of any federal, state or local law regulating the work and the Garfield County Building (County Regulation(s)). 1 acknowledge that the Building Permit may be suspended or revoked, upon notice from the County, if the location, above, are not in compliance with County Regulation(s) or any other applicable law. the property, described above, to inspect the work. I further acknowledge that the issuance of the Building Permit does not prevent the in the submittals, if any, discovered after issuance; or (2) stopping construction or use of the structure(s) or facility(ies) if such is in violation of the work by the Building Department do not constitute an acceptance of responsibility or liability by the County of errors, omissions for compliance with federal, state and local laws and County Regulations rest with me and my authorized agents, including without UNDERSTAND THE NOTICE & CERTIFICATION ABOVE: c• /•i) letter of authority, signed by the Owner, must be J.,eeal Access. A Building Permit cannot be issued without Other Permits. Multiple separate permits maybe required: County Highway; Road Access or a State Void Permit. A Building Permit becomes null and void if the days after commencement. i hereby certify that I have read this Application and that the and specifications and other data submitted by me or on my Assuming completeness of the submittals and approval of this the submittals reviewed by the Building Department. In consideration of the issuance of the Building Permit, I agee Code. ISDS regulations and applicable land use regulations construction or use of the structure(s) and facility(ies), described I hereby grant permission to the Building Department to enter Building Official from: (i) requiring the correction of errors of County Regulation(s) or any other applicable law. Review of this Application, including submittals, and inspections or discrepancies. As the Owner, I acknowledge that responsibility limitati rchitec si er, engineer and/ or builder. I HE BY A N 'LED THAT I HAVE RE AND O S SI A tIJRE DATE p .1 Ai PL 1111/e.-$tQU STAFF USE ONLY Special Conditions: Adjusted Valuation: J046,502,06 Plan Check Fee: S i. yZ.- Permit Fee: /0.5 •95 Manu home Fee: -- Misc Fees: .:------- Total Fees: /7o -q 37 Fees Paid:Balance C144,1-0, Due: 75-9: 9S BP No & Issue Date: ISDS No & Issued Date: r RE-9►7o3 Setbacks: FZ,s; gZS: S I o OCC Group- C Const Type: IAC PeiG 0.,...,� Zonin pu:) 07/// BL D l crs—� RAO. / APPROVAL DATE APPROVAL DATE Building Plan Review Description of Work: Interior remodel Bin #: Location Address: 704 SKIPPER DR CARBONDALE, CO General Information Contacts Case Manager: David Bartholomew Plan Case Number: BLDG -9-1I-6998 Parcel: 239129305010 Application Date: 09/14/2011 Owner: Scott & Leah Powel & ODone]] Applicant: Scott & Leah Powel & ODonell Applicant Phone: 212-920-2640 Email: Building Engineered Foundation Driveway Permit Surveyed Site Plan Septic Permit and Setbacks Grade/Topography 30% Toning Sign -off Attach Residential Plan Review List 41/0 Road Impact Fees Minimum Application Questionnare ��`9 HOA/DRC Approval Subdivision Plat Notes Grade/Topography 40% NG / Fire Department Review"/.> Planning Issues / Valuation Determination/Fees Subdivision Plat Red Line Plans/Stamps/Sticker General Comments: Planning/Zoning Property Line Setbacks 30ft Stream Setbacks Flood Plain Building height Attach Conditions Application Signed Plan Reviewer To Sign Application Parcel/Schedule No. AIM40# Snowload Letter - Manu. Homes Soils Report Tuesday, September 27, 2011 Applicant: Job Address: Subd- Lot/block: FEE ESTIMATE FOR S/F STICK B UILT HOMES (ALL FEES ARE ESTIMATES UNTIL FINAL PLANS ARE REVIEWED) 7o sLyper I,e e<rf-.4M ha, /or- /d - J`ri,Pz/44 /Z c// ?t'.17 FINISHED LIVING SPACE: 1190 0 sf X 74.68= ) `f /) g 92 UNFINISHED BASEMENT: sf X 41.00= CRAWL SPACE: sf X 9.00= GARAGE: sf X 18.00= UNCOVERED PATIO/DECK: sf X 12.00= COVERED PATIO/DECK: sf X 24.00= MISC: & o FR 42►4),1(6 (Na. EA/WR/ ) MISC: M/t 14u, y. TOTAL VALUATION: 30,ao0 /s Sao l8/, 872 THIS SECTION WILL BE DETERMEND BY GARFIELD COUNTY BUILDING & PLANNING PLAN REVIEW FEE: PERMIT FEE: TOTAL: SEPTIC= PERMIT: PERC: GARFIELD COUNTY Building & Planning Department 108 8`" Street, Suite 401 Glenwood Springs, Colorado 81601 Telephone: 970.945.8212 Facsimile: 970.384.3470 www.ciarfield-counW.com SINGLE FAMILY OR DUPLEX BUILDING PERMIT NOTE: In order to understand the scope of work intended and to expedite the issuance of a permit, it is important that complete information be provided. Please review this document to determine if you have adequate information to design your project and to facilitate a plan review. SINGLE FAMILY OR DUPLEX BUILDING PERMIT APPLICATION CHECKLIST This checklist is to be used with all single family dwelling construction. APPLICATION FORM: Please make sure the following information is provided on the application. • Parcel number obtained from the County Assessor's Office. • Job address (assigned physical address) • Legal Description: lot, block, filing, subdivision or tract, section, township and range. • Owners name, mailing address, phone, fax, or cell. • Contactors name, mailing address, phone, fax, or cell. • Architect/Engineer's name, mailing address, phone, fax or cell. • Building size, height, number of stories, lot size. • Use of building (residential) • Class of Work (new, addition, alteration, repair, demo, move, other) • Description of work. • Type of heating (natural gas, propane, electric, other). • Sewer system (Community or ISDS), also see other items below. • Garage (attached or detached). • Driveway permit (please see other items below) • Valuation (labor and materials) see attached worksheet. OTHER ITEMS: • If you anticipate obtaining a water -tap from the City of Rifle, please provide a letter indicating that the City will provide water service. (Required to submit building permit application). • ISDS requires a septic permit application to be submitted with the building permit application. • A separate electrical permit must be obtained from the State of Colorado Electrical Board. • Prior to submittal of a building permit, you are required to show proof of legal and adequate access to the site. This may include proof of right to use a private easement, County Road & Bridge permit, or Colorado Department of Highway permit, including a Notice to Proceed. The County Road & Bridge Department can be reached at 970-625-8601. • If you anticipate excavating or grading prior to issuance of a building permit, you will be required to obtain a separate grading permit. • If you belong to a Homeowners Association (HOA), it is your responsibility to obtain written approval, if required. • Provide copies of any Resolutions and/or Land Use Permits associated with this property. • Additional Dwelling Units may require Administrative Review. • Minimum dwelling dimension is 20 ft wide x 20 feet long. • A Colorado State Licensed Electrician and Plumber must perform installation and hook-ups, unless the homeowner is performing the work. BUILDING PLANS: Two (2) sets of plans must be submitted. Plans must be 18"x24" minimum size, complete, identical, legible, and to scale. All plans will be checked at the counter for completeness. If any of the required information is missing, the building permit application cannot be accepted. SITE PLAN: Please make sure the following information is provided on the site plan. • Property address/legal description. • North Arrow and Scale on each page. • Show all property lines, building envelopes, flood plain, and easements. • Provide setback distances from boundaries, buildings, septic, well, and waterways. • Location and direction of the county or private road and driveway accessing the property. • Proposed and existing structures include sheds, barns, decks, patios, and any other buildings. • Existing and proposed grade, positive drainage around structure (to be contained on site). • Streams, rivers, creeks, springs, ponds and ditches. • Existing and proposed wells, septic tanks, leach fields, and other systems. (if applicable) • Retaining walls (engineer stamped detail required for walls over four (4) ft, measured from bottom of footing to top of wall). NOTE: Any site plan depicting the placement of any portion of the structure within fifty (50) feet of a property line or not within an established building envelope shall be prepared, stamped, and signed by a licensed surveyor. For structures to be built within a building envelope, provide a copy of the recorded subdivision final plat with the proposed structure located in the building envelope. ARCHITECTURAL PLANS: Please provide the following information on the architectural plans. • Minimum four (4) elevations (N,S,E,W) Indicate height of building measured from existing grade to the midpoint between the ridge and eave of a gable or shed roof or to the top of a flat roof. • Floor plans for each level including dimensions and scale noted. • Clearly label each room or space (bedroom, bath, kitchen, closet, etc). • Show the location of the mechanical equipment. • Building cross sections with construction details. • Window sizes, types, and operation noted on the floor plans or elevations. • Specify roof slope/pitch, roof covering, and siding materials. • Stair and guard details specifying rise, run, height and spacing. • Attic, roof, and crawlspace ventilation details. Indicate size and location of ventilation openings. • Minimum insulation shown for walls, floors, roofs/ceilings, slabs, basements and crawlspaces. • Provide stove and fireplace make, model, EPA or Colorado Phase II Certification. Masonry fireplaces shall be designed to the International Residential Code (IRC) requirements. STRUCTURAL PLANS: Please provide the following information on the structural plans. • Design specifications to include roof and deck snow load, wind and seismic design, frost depth. • Foundation plan showing complete footing and foundation dimensions. • Footing and foundation details specifying reinforcement and referenced on plans. • Framing plans for each floor level and roof. All beams, columns, joists, rafters, and trusses specified. Pre -manufactured structures require the engineers stamp, signature, and date. • Framing /connection details, braced wall lines, shear wall schedule, location and hold downs. NOTE: If any required information is missing, delays in issuing the permit are to be expected. If determined by the Building Official that additional information is necessary to review the application and/or plans for compliance, the application may be placed on hold until the required information is provided. Work may not proceed without the issuance of a permit. The building department will collect a Plan Review fee at time of application submittal. The permit fee, as well as any Septic or Road Impact fees will be collected when the permit is issued. The permit application must be signed by the owner or by person having written authority from the owner to act as their representative. Building cannot be occupied until a Certificate of Occupancy (CO) is issued. Using the building without a CO will be considered an illegal occupancy and may be grounds for vacating the premises. (Final/CO inspection requirements will be attached to your approved field set of plans.) I hereby acknowiedgtl have read, understand, and will abide by the requirements of this checklist. Signature of Owner ��I �I1 Date Garfield County Building & Planning 108 8`h Street, Suite 401 Glenwood Springs, CO 81601 Phone: 970-945-8212 Fax: 970-384-3470 www.qarfield-county.com Powell Remodel Review Stirling Ranch D.R.B. Meeting Notes: 704 Schooner Ln. Lot #10 Present: Christine Bergstrom - Stirling Ranch DRB Lindsay Harris DRB (Available by Phone) Mike Otte DRB (Available by Phone) Glenn Rappaport- DRB Review Architect The proposal is to remodel a portion (roughly 1,900 sq. ft.) of the existing structure, adding new doors and windows, re -roofing and repairing the existing roofs, kitchen remodel, updated mechanical room and new plumbing fixtures. There is no increase in floor area and no additions to the existing footprint. Discussed: 1. General Visual Impact: None 2. Neighbor Concerns: None 3. Materials: n/a Approval: Re -model design approval is granted based on the drawing set dated 08.17. 2011 handed out at the meeting . Submitted by: Glenn H. Rappaport AIA Principal Black Shack Architects 9 9 ii black shack office post office box 1847 basalt colorado 81621 blackshackoffice.com ph 970 927 0635 fx 970 927 0654 Powell Remodel Revie Stirling Ranch D.R.B. Meeting Notes: 704 Schooner Ln. Lot #10 Present: Christine Bergstrom - Stirling Ranch DRB Lindsay Harris DRB (Available by Phone) Mike Otte DRB (Available by Phone) Glenn Rappaport- DRB Review Architect The proposal is to remodel a portion (roughly 1,900 sq. ft.) of the existing structure, adding new doors and windows, re -roofing and repairing the existing roofs, kitchen remodel, updated mechanical room and new plumbing fixtures. There is no increase in floor area and no additions to the existing fdotprint. Discussed: 1. General Visual Impact: None 2. Neighbor Concerns: None 3. Materials: n/a Approval: Re -model design approval is granted based on the drawing set dated 08.17. 2011 handed out at the meeting . Submitted by: Glenn H. Rappaport AIA Principal Black Shack Architects 1/ 9 black shack office post office box 1847 basalt colorado 81621 blackshackoffice.com ph 970 927 0635 fx 970 927 0654 %%wtll Sera eVAL. September 7, 2011 Glenn Rappaport, AIA, principal Post Office Box 1847 Basalt, Colorado 81621 RE: Site Evaluation—Onsite Wastewater System (OWS) Evaluation, Existing System Conditions for Single Family Residence located 704 Skipper Drive on Lot 10, Stirling Ranch PUD in Garfield County, Colorado. SE Proposal No. 11145.01 Parcel No. 239129305010 Dear Glenn: Pursuant to your request, this letter presents our findings in regard to the existing Onsite Wastewater Systems (OWS) associated with the above referenced Site. It is our understanding that you are currently applying to Garfield County for a building permit to allow limited remodeling activities inside the home. Two individual systems are currently in operation to serve the needs of the existing 4 -bedroom home on the site. The systems were constructed under separate County issued ISDS permits. We have located and performed inspections of certain OWS components, reviewed previous perniit information and have observed the existing site conditions. We understand that our initial investigation is to provide an opinion of the system's adequacy for continued usage to treat sewage from the residence. Our findings and recommendations are based on our current knowledge of the site conditions with respect to information provided by others. Conclusions In our opinion we believe that the systems appear adequate to serve the needs of the residence in the short term and that the systems can be utilized without any immediate maintenance required. Evidence of general tank, field or piping problems or failures was not observed with either systems and typical system function is expected under average usage. The systems are in general compliance with State and County standards to accommodate the design flow from the proposed dwelling based on our review of the permit documents. Findings Onsite wastewater system's sewer lines, tanks and cleanout were located and inspected by TV and field probe methods conducted on August 16, 2011 by Bishop Plumbing and observed by Sopris Engineering. The located components were surveyed and incorporated into an existing conditions map. The East system (Permit No. 1580) was constructed in 1987 was inspected by the County. The system consists of a 1250 gallon 2 -chamber concrete septic tank with a reported 18' by 30' absorption field installed to serve a two bedroom residence. The reported percolation rate indicated on the permit is 15 minutes per inch. Our TV investigation revealed that the sewer pipes in the house and the single 4" PVC line out to the tank are in good condition and function as expected. The sludge layer in the primary compartment of the septic tank is approximately 12" deep and relatively light. The clear zone appears normal and a limited amount of scum was observed at the liquid level. Approximately 100 gallons of water was drained into the tank during our investigation and flow patterns suggested adequate operation 502 Main Street • Suite A3 • Carbondale, CO 81623 • (970) 704-0311 • Fax (970) 704-0313 SOPRIS ENGINEERING • LLC civil consultants Glenn Rappaport SE Job No. 11145.01 September 7, 2011 Page 2 of 2 through the lines and tank. The tank is not in need of pumping however both tank chambers should be inspected within a year or after an extended period of full usage next spring. The West system (Permit No. 1689) was constructed to accommodate a 2 bedroom addition and was inspected by the County. The system consists of a 1000 gallon 2 -chamber concrete septic tank with a reported 24' by 40' absorption field installed to serve a two bedroom residence. The reported percolation rate indicated on the permit is 15 minutes per inch. Our TV investigation revealed that the sewer pipes in the house and the single 4" PVC line out to the tank are in good condition and function as expected. The sludge layer in the primary compartment of the septic tank is approximately 4" deep and light. The clear zone appears normal and a limited amount of scum was observed at the liquid level. Approximately 50 gallons of water was drained into the tank during our investigation and flow patterns suggested normal operation through the lines and tank. The tank is not in need of pumping however both tank chambers should be inspected within a year or after an extended period of full usage next spring, Please contact us if you have any questions or concerns. Sincerely, SOPRIS ENGINEERING, LLC s ' Sohedule of Hourly Rates, Authorization for Professional Services September 7, 2011 Glenn Rappaport, AIA, principal Post Office Box 1847 Basalt, Colorado 81621 RE: Site Evaluation—Onsite Wastewater System (OWS) Evaluation, Existing System Conditions for Single Family Residence located 704 Skipper Drive on Lot 10, Stirling Ranch PUD in Garfield County, Colorado. SE Proposal No. 11145.01 Parcel No. 239129305010 Dear Glenn: Pursuant to your request, this letter presents our findings in regard to the existing Onsite Wastewater Systems (OWS) associated with the above referenced Site. It is our understanding that you are currently applying to Garfield County for a building permit to allow limited remodeling activities inside the home. Two individual systems are currently in operation to serve the needs of the existing 4 -bedroom home on the site. The systems were constructed under separate County issued ISDS permits. We have located and performed inspections of certain OWS components, reviewed previous permit information and have observed the existing site conditions. We understand that our initial investigation is to provide an opinion of the system's adequacy for continued usage to treat sewage from the residence. Our findings and recommendations are based on our current knowledge of the site conditions with respect to information provided by others. Conclusions In our opinion we believe that the systems appear adequate to serve the needs of the residence in the short term and that the systems can be utilized without any immediate maintenance required. Evidence of general tank, field or piping problems or failures was not observed with either systems and typical system function is expected under average usage. The systems are in general compliance with State and County standards to accommodate the design flow from the proposed dwelling based on our review of the permit documents. Findings Onsite wastewater system's sewer lines, tanks and cleanout were located and inspected by TV and field probe methods conducted on August 16, 2011 by Bishop Plumbing and observed by Sopris Engineering. The located components were surveyed and incorporated into an existing conditions map. The East system (Permit No. 1580) was constructed in 1987 was inspected by the County. The system consists of a 1250 gallon 2 -chamber concrete septic tank with a reported 18' by 30' absorption field installed to serve a two bedroom residence. The reported percolation rate indicated on the permit is 15 minutes per inch. Our TV investigation revealed that the sewer pipes in the house and the single 4" PVC line out to the tank are in good condition and function as expected. The sludge layer in the primary compartment of the septic tank is approximately 12" deep and relatively light. The clear zone appears normal and a limited amount of scum was observed at the liquid level. Approximately 100 gallons of water was drained into the tank during our investigation and flow patterns suggested adequate operation 502 Main Street • Suite A3 • Carbondale, CO 81623 • (970) 704-0311 • Fax (970) 704-0313 SOPRIS ENGINEERING • LLC civil consultants Glenn Rappaport SE Job No. 11145.01 September 7, 2011 Page 2 of 2 through the lines and tank. The tank is not in need of pumping however both tank chambers should be inspected within a year or after an extended period of full usage next spring. The West system (Permit No. 1689) was constructed to accommodate a 2 bedroom addition and was inspected by the County. The system consists of a 1000 gallon 2 -chamber concrete septic tank with a reported 24' by 40' absorption field installed to serve a two bedroom residence. The reported percolation rate indicated on the permit is 15 minutes per inch. Our TV investigation revealed that the sewer pipes in the house and the single 4" PVC line out to the tank are in good condition and function as expected. The sludge layer in the primary compartment of the septic tank is approximately 4" deep and light. The clear zone appears normal and a limited amount of scum was observed at the liquid level. Approximately 50 gallons of water was drained into the tank during our investigation and flow patterns suggested normal operation through the lines and tank. The tank is not in need of pumping however both tank chambers should be inspected within a year or after an extended period of full usage next spring. Please contact us if you have any questions or concerns. Sincerely, SOPRIS ENGINEERING, LLC Sti't Schedule of Hourly Rates, Authorization for Professional Services Account Page 1 of 1 Account: R008785 Location Parcel Number 2391-293-05-010 Situs Address 704 SKIPPER DR 704162A COUNTY RD City Carbondale Carbondale ZipCode 81623 81623 Tax Area 011 - 1R -MF -�I1 Legal Summary Section: 29 Township: 7 Range: 87 Subdivision: STIRLING RANCH PUD Lot: 10 Transfers Tax History Tax Year * Estimated Sale Price $680,000 Taxes *2011 $4,265.96 2010 $6,075.84 Owner Information Owner Name POWELL, SCOTT T & LEAH O'DONNELL Owner Address 259 E 7TH STRETT 3E NEW YORK, NY 10009 Assessment History Actual (2011) $940,540 Primary Taxable $74,860 Tax Area: 011 Mill Levy: 56.9860 Type Actual Assessed Acres SQFT Units Improvement $675,540 $53,770 0.000 0.000 1.000 Land $265,000 $21,090 12.426 0.000 0.000 Sale Date Doc Type 03/30/2011 434 03/18/2011 4 12/27/2010 250 03/06/2008 SWD Images • Map • Sketch • GIS Focusing On: 704 SKIPPER DR CARBONDALE 81623 4 Ret Rttrite. co Sid 100 0 Cogdrl Co Rd 102 3 Book Page Fender Ln Map data ©2011 Google - https://act.garfield-county.com/assessor/taxweb/account jsp?accountNum=R008785 9/14/2011 Permit Card Garfield County Building and Planning Department 108 8th Street, Suite 401 Glenwood Springs. CO 81601 Phone: (970)945-8212 Fax. (970)384-3470 POST ON SITE Permit NO. B L R E 9 -11-22 0 3 Permit Type: Residential Building Work Classification: Addition Issue Date: 9/29/2011 Expires: 03/27/2012 AGREEMENT In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structured for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building department and IMMEDIATELY BECOME NULL AND VOID. Residential Building Parcel #:239129305010 Owner's Name: Scott & Leah Powel & ODonell Job Address: 704 SKIPPER DR CARBONDALE, CO Owner's Phone: 212-920-2640 Total Square Feet: 0 Contractor(s) Crystal Springs Builders Phone Primary Contractor (970)963-4584 Yes Work Description: Interior remodel on a single family dwelling Inspection Scheduling Code Ins section IVR Comments Pass Date Footers 105 Foundation Walls 110 Framing 115 th/P/t/6- /(MC, 7i ---,6I/6-, 5� z;;?e-'. r/i4 `t'( Drywall 120 Final 125 uv- til, L_/—/E ,—/—/E Misc 135 160 Grout 175 Mechanical 405 UG Plumbing -- /</7.7 605" � /^4_//' Rough Plumbing 610 f t /—�r// .1/_ / %/ Gas 620 r:.i DN fAc-k -- /-git/J///G /'L.160 - C,o P( C 25 /47-5 AL Fi A 4 L (7/7/2 - ADDITIONAL //2 - ADDITIONAL INSPECTIONS MAY BE REQUIRED POST THIS IN CONSPICUOUS PLACE WHEN CONSTRUCTION IS STARTED For Inspections Call: 1-888-868-5306 Project Address Garfield County Building & Planning Department 108 8th Street Suite 401 Glenwood Springs, CO 81601 - Phone: (970)945-8212 Fax: (970)384-3470 704 SKIPPER DR CARBONDALE, CO Owner Information Parcel No. 239129305010 Address Issue Date: 9/29/2011 Expires: 03/27/2012 Subdivision STIRLING RANCH PUD Scott & Leah Powel & ODonell 350 madison AVE CO 10017 • Phone Cell GARFIELD COUNTY 212-920-261UILDING & PLANNING ,43", .MFkixtianl,A1.4.31.16144.AMIRVAWIAAN Contractor(s) Phone Primary Contractor Crystal Springs Builders (970)963-4584 Yes Proposed Construction/Details Interior remodel on a single family dwelling FEES DUE Plan Check Fee Residential Building Fee Total: Amount, $671.42 $1,032.95 $1,704.37 Valuation: Total Sq Feet: $ 106,500.00 0 FEES PAID Inv'Total Paytype Amt Paid Ar it Due Inv # BLRE-9-11-21395 $ 1,704.37 Check # 1016 Credit Card $944.42 $759.95 $ 0.00 Required Inspections: For Inspections call : 1(888)868-5306 Inspection IVR Footers 105 Foundation Walls 110 Framing 115 Drywall 120 Final 1,25 Mlsc 135 Insulation 160 Grout 175 Mechanical 405 UG Plumbing 605 Rough Plumbing 610 Gas 620 - illlltt. IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: 1. Final inspection of the work authorized by this permit is required. A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings, structures and remodeling work. Applicant Copy This permit/plan review expires by time limitation and becomes null and void if the work authorized by the permit is not commenced within 180 days from the date of permit issuance or if the permit Is not obtained within 180 days from the date of plan submittal. This permit expires and becomes null and void if any work authorized by this permit is suspended or abandoned for 180 consecutive clays or if no progressive work has been verified by passing a required County Inspection for a period of 180 consecutive days. 00 , 9G3 �as6 Li t -x{ �i Thursday, September 29, 2011 gislvns I, /I79Q &d f2/4745 rA,r/e5 /N,7 t'97/4/ /1/ p/ s /7.),/,' 1 11.30.11 powell residence Per the revised "proposed roof plan" on the attached A2.2 sheet, the existing flat roof area clouded will be repaired and a new membrane added. No additional slope or framing will be added. Copies /i/s9r/e,/i//y4lp/ S 0 GLMINAAPPAPOIIT 9 - black shack architects basalt colorado 81 blackshackoffice.c ph 970 927 ( fx 970 927 ( Riz plan area of raised claresbrY Hill OHOHIOH 11111114 41 fine of pha 2 roof overhang FLAT rle af roofexteoverhangirlorvIsivbeieler0)(7.1.i.) Ine o 01 proposed v.cr roof plan existing roof notes: • rePlase eviSling metal roof all new standing Saani to meta exis19 phase 2 roofing (color and dimension) • repair alt Safe penetrations and membranes • repair all son areas /to n 0 087.2411 1 0 1 0 8..0177..111 1 1009.09.11 11.30.11 coodwg pernicoorderdireln:lonon OR Indian 00bleng,idilwsubmittal I revision