HomeMy WebLinkAboutPlans (2)RIDGE BEAM. 5EE STRUCT.
+T. FASCIA
V.I.F.
MATCH EXISTING
COAT HOOKS PER INTERIOR DESIGNER
STONE VENEER
2x6 0 16" 0.G. EXTERIOR WALLS
(R20 MINIMUM INSULATION)
MINIMUM 4 -MIL VAPOR BARRIER
REQUIRED ON INTERIOR FACE
OF CAVITY INSULATION WALLS
BUILT-IN STORAGE PER INTERIOR DESIGNER
ofr
CLOSED CELL SPRAY -IN FOAM
INSULATION (R3S MINIMUM)
2x RAFTERS. SEE STRUCT.
FOR DEPTH AND SPACING.
12
12
0 0
GRADE BEAM. REFER
TO STRUCTURAL.
11=11=111=1_0_
0
0 0 0
FLOOR JOISTS.
REFER TO STRUCTURAL.
WOOD BEAM. SEE STRUCT.
METAL ROOFING SYSTEM
CLOSED CELL SPRAY -IN FOAM
IN5ULATIQ t (It98 MINS
12
HALL AAY
BE -(O
2x RAFTERS. SEE STRUCT.
FOR DEPTH AND SPACING.
ROOF SHEATHING.
REFER TO STRUCTURAL.
WOOD SIDING TO
MATCH EXISTING
CLOSED
INSULATI
12
1 4.'15
Y -IN FOAM
INIMUM)
2x RAFTERS. SEE STRUCT.
FOR DEPTH AND SPACING.
P o Vl Jet/II-eel-,15 1--ew s
rev Zoog Lam, g, 8o6• -J
T. FASCIA IS)
V.I.F.
MATCH EXISTING
OVtIER TO COORDINATE WITH
BUILDER REGARDING FASCIA,
SOFFIT, FLASHING AND STONE
TERMINATION DETAILS
WALL SHEATHING.
REFER TO STRUCTURAL.
STONE VENEER
A 16' O.G. EXTERIOR WALLS
(R20 ' INIMUM INSULATION)
TILE LINED
WOOD STORAGE
I I I
GRAWLSfi AGE
1
1-6 7
MINIMUM 4 -MIL VAPOR BARRIER
REQUIRED ON INTERIOR FACE
OF CAVITY INSULATION WALLS
5/6" GYP -BOARD
HOUSE WRAP
AIR SPACE WITH DRAINAGE MAT
FULL HEIGHT OF MASONRY WALL
PROVIDE WEEP HOLES
ABOVE GRADE A 2'-0" 0.G.
I I I
CLASS I VAPOR RETARDER
WITH OVERLAPPING JOINTS
TAPED PER IRC NI102.2.9
BUILDING SECTION - ENTRY
SCALE: 3/4" ■ 11-0 on 22" x 34'
SCALE: 3/6' : I'-0 on II" x IT"
•
e•
T. PLYWOOD
100'-0"
TO MATCH EXISTING
RIGPOLYSTYRENE (CLOSED CELL)
(RI • INIMUM) OVER DAMPPROOFING
GRADE BEAM. REFER
TO STRUCTURAL.
= UNVENTED GRAWLSPAGE
• 4 PER IRC R406
•
e/ealird fen -14 /11 APAZOvt/ /5
,t li/ted n't Ae frovetizion .
e/ec4/c,/ /4' 4,4/ 4,-te��/ /5
/efi--
WEE:
CONTRACTOR TO PROVIDE
ALL WATERPROOFING,
DRAINAGE AND FLASHING
AS REQUIRED.
Floors over vented crawlspaces must be insulated; R-30 or enough to fill the cavity. Vents shall be
located below the bottom of the floor joist per IRC, R-408.1. As an alternative to insulating floors,
crawlspace walls shall be permitted to be insulated when the space is not vented to the outdoors and
meets the requirements of IRC, R-408.3. Take precautions to protect plumbing in these areas.
5,K. PEIGHTAL ENGINEERS
PROVIDES THE A -SERIES
SHEETS INA DRAFTING ROLE
ONLY, AT THE OWNER'S
DIRECTION, A -SERIES
DOCUMENTS INDICATE DESIGN
BY THE OWNER S.K. PEIGHTAL
ENGINEERS WAIVES ANY AND
ALL RESPONSIBILITY AND
LIABILITY FOR PROBLEMS
WHICH ARISE FROM FAILURE TO
FOLLOW THESE PLANS AND THE
DESIGN INTENT THEY CONVEY,
OR FOR PROBLEMS WHICH
ARISE FROM OTHERS' FAILURE
TO OBTAIN AND/OR FOLLOW
GUIDANCE OF 5.K. PEIGHTAL
ENGINEERS WITH RESPECT TO
ANY ERROR5, OMISSIONS,
INCONSISTENCIES, AMBIGUITIES,
OR CONFLICTS WHICH ARE
ALLEGED.
SKPE
S K PEIGHTAL ENGINEERS
204 PARK AVENUE UNIT IC
BASALT, COLORADO 81621
PHONE: (970) 927-9510
OLSON ADDITION
5648 COUNTY ROAD 245
GARFIELD COUNTY, CO
ISSUE:
08/28/12 PERMIT
JOB* 12023
SHEET:
A3.1
io
L — J
T
I®I
L — J
I■
H.
n T
i®
L — J
T
L — J
101
L — J
r
J
ry�
1
L_
2- 2x6 COLUMN
W/ DMZ
HOLDOWN
*5 x 30" DOWELS • 16° 0.G.
DRILL AND EPDXY 5" INTO
EXISTING CONCRETE.
PROVIDE GRAWLSPAGE
ACCESS PER IRC R408.4.
SAW -CUT EXISTING WALL.
NO IMPACT
FLOOR FRAMING 51ZED
FOR NO STONE OR
CONCRETE TOPPINGS.
T. LEDGE
qq'-0"
CRAWL SPACE
t-
_ I (E) BEAM LINE
I -T--
BASEMENT
BUILDER TO VERIFY
EXISTING MEMBER SIZES
AND INTERMEDIATE
SUPPORT THIS LINE
7. (E) PL"W000
00'-0
ext
lUe
b
ti es. f*
-' \ T. LEDGE
CN' -O°
15-6"
Q r4
i
FOUNDATION AND MAIN FLOOR FRAMING FLAN
2- 2x6 COLUMN
W/ 71722
HOEDOWN
*5 x 30" DDYe.S • 16" 0.G.
DRILL AND EPDXY 5" INTO
EXISTING CONCRETE.
T. LEDGE
q6'-0"
70/-Z 8/Z -
SCALE: 1/4' ■ I'-0 on 22" x 34"
SCALE: I/8' = I'-0 on 11" x 11"
FOUNDATION PLAN NOTES
I. TW INDICATES TOP OF GONG. WALL ELEVATION
2, TF INDICATES TOP OF CONC. FOOTING ELEVATION
5. TL INDICATES TOP OF CONC. LEDGE ELEVATION
4. INDICATES TOP OF FOOTING ELEVATION STEP
5. N INDICATES TOP OF GONG. WALL ELEV. STEP
6. R` INDICATES SURFACE PLANE STEP IN ELEV.
INDICATES COLUMN ABOVE. 2- 2x6 TYP. U.N.D.
COLUMNS SIZED AT LOWEST POINT, AND
REMAINTHAT SIZE FOR EACH LEVEL UNLESS
CHANGED BY NOTE.
8.
INDICATES PAD FOOTING. SEE PAD FOOTING
SCHEDULE THIS JFICL7.
INDICATE -5 BUILDING ELEVATION
10. [XXX' -XX"] INDICATE -5 TOP OF BEAM ELEVATION
II. INDICATES JOIST BEARING
12. INDICATE -5 JOIST HANGING
15. — — INDICATE -5 4" 9 PVC FOUNDATION DRAIN,
SET IN 6RAEL AS ON ARG. DRAWINGS
14. ALL CONCRETE WALLS ARE 10° THICK, U.N.D.
15. VENT CRAWLSPAGE AREAS PER UBC SEC. 2516. (0). 6.
PROVIDE BLOGKOUTS IN FOUNDATION WALLS A5 REQUIRED.
SEE GENERAL NOTES FOR REINFORCING.
16, DO NOT SCALE DRAYVINGS. CONTACT ARCHITECT OR
ENGINEER FOR DISCREPANCIES OR MISSING DIMENSIONS.
E
SKP'E
S K PEIGHTAL ENGINEERS
204 PARK AVENUE UNIT IC
BASALT, COLORADO 81621
PHONE: (970) 927-9510
OLSON ADDITION
5648 COUNTY ROAD 243
—rti
TW qq'-q 3/4"
TW qq'-q 3/4°
I
4
1
1
1
1
BW qb'-0"
•
BW q6' -O"
11 1L
7 7 _E,
J0E34* 12025
SHEET:
s1.1
PLYWOOD
mF. U.N.O.
-3
+T.
ot 1001-0"
MATCH EXISTING
■
ry.6%
® T3/4°
b'-O
qb'-00"
tr
�TF
■
�■ ■
A ■
■
-' \ T. LEDGE
CN' -O°
15-6"
Q r4
i
FOUNDATION AND MAIN FLOOR FRAMING FLAN
2- 2x6 COLUMN
W/ 71722
HOEDOWN
*5 x 30" DDYe.S • 16" 0.G.
DRILL AND EPDXY 5" INTO
EXISTING CONCRETE.
T. LEDGE
q6'-0"
70/-Z 8/Z -
SCALE: 1/4' ■ I'-0 on 22" x 34"
SCALE: I/8' = I'-0 on 11" x 11"
FOUNDATION PLAN NOTES
I. TW INDICATES TOP OF GONG. WALL ELEVATION
2, TF INDICATES TOP OF CONC. FOOTING ELEVATION
5. TL INDICATES TOP OF CONC. LEDGE ELEVATION
4. INDICATES TOP OF FOOTING ELEVATION STEP
5. N INDICATES TOP OF GONG. WALL ELEV. STEP
6. R` INDICATES SURFACE PLANE STEP IN ELEV.
INDICATES COLUMN ABOVE. 2- 2x6 TYP. U.N.D.
COLUMNS SIZED AT LOWEST POINT, AND
REMAINTHAT SIZE FOR EACH LEVEL UNLESS
CHANGED BY NOTE.
8.
INDICATES PAD FOOTING. SEE PAD FOOTING
SCHEDULE THIS JFICL7.
INDICATE -5 BUILDING ELEVATION
10. [XXX' -XX"] INDICATE -5 TOP OF BEAM ELEVATION
II. INDICATES JOIST BEARING
12. INDICATE -5 JOIST HANGING
15. — — INDICATE -5 4" 9 PVC FOUNDATION DRAIN,
SET IN 6RAEL AS ON ARG. DRAWINGS
14. ALL CONCRETE WALLS ARE 10° THICK, U.N.D.
15. VENT CRAWLSPAGE AREAS PER UBC SEC. 2516. (0). 6.
PROVIDE BLOGKOUTS IN FOUNDATION WALLS A5 REQUIRED.
SEE GENERAL NOTES FOR REINFORCING.
16, DO NOT SCALE DRAYVINGS. CONTACT ARCHITECT OR
ENGINEER FOR DISCREPANCIES OR MISSING DIMENSIONS.
E
ti.
BASEMENT
1
LINTEL L 4x4x5/8 WITH I/2"4, x 5"
TITEN HD SCREW ANCHORS it 24" 0.C.
TYPICAL A5 INDICATED. LINTEL
SIZED TO SUPPORT MAXIMUM 6"
THICK STONE VENEER WITH HEIGHT
NOT TO EXCEED 3'-0". PROTECT ALL
STEEL BELOW GRADE WITH
ASPHALTIC PAINT.
/Cfy%Ode/ , eey v,dte
/d,&oL//.
e,27/11Pe7
• e146,/ t 9%,„7 4y ct/.t/ /s
peuirec1 �1/ Wim' e
e/t--177/c,/ yi'rv,s/ /5
„geied/%-C407,4 cornis,4 //,Avec/#Yl
dpekt 14612 soils Reps"!
g quived 4-7- Foofen9
14517€(.47un ° z00017SA
NQM:
SEE ARCH. FOR
ALL DIMENSIONS
4 ELEVATIONS
NOT INDICATED..
ALL HALF -TONE MEMBERS
INDICATED A5 (E) ARE
EXISTING AND ASSUMED.
BUILDER TO FIELD VERIFY
AND NOTIFY ENGINEER OF
ANY DIFFERENCES FROM
THAT INDICATED.
5.K. PEIGHTAL ENGINEERS
WAIVES ANY AND ALL
RESPONSIBILITY AND LIABILITY
FOR PROBLEMS WHICH ARISE
FROM FAILURE TO FOLLOW
THESE PLANS AND THE DESIGN
INTENT THEY CONVEY, OR FOR
PROBLEMS WHICH ARISE FROM
OTHERS' FAILURE TO OBTAIN
AND/OR FOLLOW GUIDANCE OF
S.K. PEIGHTAL ENGINEERS WITH
RESPECT TO ANY ERRORS,
OMISSIONS, INCONSISTENCIES,
AMBIGUITIES, OR CONFLICTS
WHICH ARE ALLEGED.
TS ESE DRAWINGS ARE TO BE
USED WITH THE ARCHITECTURAL
DRAWINGS ON THE PROJECT TO
CLEARLY DEFINE ALL OF THE
REQUIREMENTS FOR
CONSTRUCTION. WHERE
CONFLICTS OCCUR, CONTACT
ARCHITECT FOR CLARIFICATION.
SKP'E
S K PEIGHTAL ENGINEERS
204 PARK AVENUE UNIT IC
BASALT, COLORADO 81621
PHONE: (970) 927-9510
OLSON ADDITION
5648 COUNTY ROAD 243
GARFIELD COUNTY, CO
1
1
1
I
4
1
1
1
1
�1
11
11 1L
7 7 _E,
J0E34* 12025
SHEET:
ti.
BASEMENT
1
LINTEL L 4x4x5/8 WITH I/2"4, x 5"
TITEN HD SCREW ANCHORS it 24" 0.C.
TYPICAL A5 INDICATED. LINTEL
SIZED TO SUPPORT MAXIMUM 6"
THICK STONE VENEER WITH HEIGHT
NOT TO EXCEED 3'-0". PROTECT ALL
STEEL BELOW GRADE WITH
ASPHALTIC PAINT.
/Cfy%Ode/ , eey v,dte
/d,&oL//.
e,27/11Pe7
• e146,/ t 9%,„7 4y ct/.t/ /s
peuirec1 �1/ Wim' e
e/t--177/c,/ yi'rv,s/ /5
„geied/%-C407,4 cornis,4 //,Avec/#Yl
dpekt 14612 soils Reps"!
g quived 4-7- Foofen9
14517€(.47un ° z00017SA
NQM:
SEE ARCH. FOR
ALL DIMENSIONS
4 ELEVATIONS
NOT INDICATED..
ALL HALF -TONE MEMBERS
INDICATED A5 (E) ARE
EXISTING AND ASSUMED.
BUILDER TO FIELD VERIFY
AND NOTIFY ENGINEER OF
ANY DIFFERENCES FROM
THAT INDICATED.
5.K. PEIGHTAL ENGINEERS
WAIVES ANY AND ALL
RESPONSIBILITY AND LIABILITY
FOR PROBLEMS WHICH ARISE
FROM FAILURE TO FOLLOW
THESE PLANS AND THE DESIGN
INTENT THEY CONVEY, OR FOR
PROBLEMS WHICH ARISE FROM
OTHERS' FAILURE TO OBTAIN
AND/OR FOLLOW GUIDANCE OF
S.K. PEIGHTAL ENGINEERS WITH
RESPECT TO ANY ERRORS,
OMISSIONS, INCONSISTENCIES,
AMBIGUITIES, OR CONFLICTS
WHICH ARE ALLEGED.
TS ESE DRAWINGS ARE TO BE
USED WITH THE ARCHITECTURAL
DRAWINGS ON THE PROJECT TO
CLEARLY DEFINE ALL OF THE
REQUIREMENTS FOR
CONSTRUCTION. WHERE
CONFLICTS OCCUR, CONTACT
ARCHITECT FOR CLARIFICATION.
SKP'E
S K PEIGHTAL ENGINEERS
204 PARK AVENUE UNIT IC
BASALT, COLORADO 81621
PHONE: (970) 927-9510
OLSON ADDITION
5648 COUNTY ROAD 243
GARFIELD COUNTY, CO
ISSUE:
OS/01/12 PROGRESS
08/28/12 PERMIT
J0E34* 12025
SHEET:
s1.1
EDE
rTh
X
GUEST
BAS
GUEST
BEDROOM
05 1
0
r
MSTA 16 VERTICAL
SLOPED VL TO COLUMN
eilea/Ne' saYt 551
(
PERFORATED
SHEAR 6'-0"
IPERFORATED
SHEAR WALL
ci
0
a
0
T
4
1f. -IF'. OVERFRAMIN6 PER
04 DETAIL 4/55.1. TYPICAL
A5 INDICATED.
3- i I/4" VL
• 2- 2x6
I K. POST
2
NEW ENTRY
FOYEF
101
v
W
MSTA IS VERTICAL
SLOPED VL TO COLUMN
See 4;#Het1/rn'rs
3- 2x6
K. POST
3
X41
C%
ROOF FRAMING FLAN
SCALE: I/4" = I'-0 on 22" x 34"
SCALE: VS" = 1'-0 on 11" x 11"
LOOSE LINTEL L 6x4x1/4
TYPICAL AS INDICATED.
BEAR BOTH ENDS 3" MIN.
ON MASONRY BELOW.
ma gm.
gm -
S3. %
5`
i
RAFTER ALLOWABLE SPAN
RAFTER
SPAN
2x12 $ 24" O.G.
L max = 13'-0"
2x10 a 24" O.G.
L max = 11'-D"
2x8 a 24" 0.G.
L max = q' -D"
ROOF FRAMING PLAN NOTES
I. ❑ OR 0 INDICATES COLUMN BELOW
2. INDICATES RAFTER BEARING
3. E INDICATES RAFTER HAN6IN6
INDICATES MOMENT CONNECTION
5. INDICATES ROOF PITCH BREAK
b. INDICATES 1/2" PLYWOOD SHEAR PANELS
FOR EXTENT INDICATED. PROVIDE NAILING
A5 NOTED IN GENERAL NOTES.
7. [XXX' -XX ] INDICATES TOP OF BEAM ELEVATION
8. H VT wu i INDICATE -5 OVERFRAMING
SHEAR
[X' -XX"]
q. ALL COLUMNS SHALL BE 2- 2x6 UNLESS NOTED OTHERWISE
10. ALL HEADERS UNLESS NOTED OTHERWISE SHALL BE 5- 2x10
OR 2-ct I/2" VL WITH 2" RIGID INSULATION. COORDINATE
WITH ARCHITECT. NO INSULATION AT INTERIOR WALLS.
II. ALL SLOPED ROOF SHEATHING TO BE 5/8" GDX PLYWOOD
WITH NAILING A5 NOTED IN GENERAL NOTES.
12. ALL LEVEL ROOF SHEATHING TO BE 3/4" GDX PLYWOOD
WITH NAILING AS NOTED IN GENERAL NOTES.
13. DO NOT SCALE DRAWINGS. CONTACT ARCHITECT OR
ENGINEER FOR DISCREPANCIES OR MISSING DIMENSIONS.
NOTE.
SEE ARCH. FOR
ALL DIMENSIONS
4 ELEVATIONS
NOT INDICATED..
NOTE:
ALL HALF -TONE MEMBERS
INDICATED AS (E) ARE
EXISTING AND ASSUMED.
BUILDER TO FIELD VERIFY
AND NOTIFY ENGINEER OF
ANY DIFFERENCES FROM
THAT INDICATED.
S.K. PEI&HTAL ENGINEERS
WAIVES ANY AND ALL.
RESPONSIBILITY AND LIABILITY
FOR PROBLEMS WHICH ARISE
FROM FAILURE TO FOLLOW
THESE PLANS AND THE DESIGN
INTENT THEY CONVEY, OR FOR
PROBLEMS WHICH ARISE FROM
OTHERS' FAILURE TO OBTAIN
AND/OR FOLLOW GUIDANCE OF
5.K. PEI&HTAL ENGINEERS WITH
RESPECT TO ANY ERROR5,
OMISSIONS, INCONSISTENCIES,
AMBIGUITIES, OR CONFLICTS
WHICH ARE ALLEGED.
THESE DRAWINGS ARE TO BE
USED WITH THE ARCHITECTURAL
DRAWINGS ON THE PROJECT TO
CLEARLY DEFINE ALL OF THE
REQUIREMENTS FOR
CONSTRUCTION. WHERE
CONFLICTS OCCUR, CONTACT
ARCHITECT FOR. CLARIFICATION.
S K. P =E
S K PEIGHTAL ENGINEERS
204 PARK AVENUE UNIT IC
BASALT, COLORADO 81621
PHONE: (970) 927-9510
OLSON ADDITION
5648 COUNTY ROAD 243
GARFIELD COUNTY, CO
ISSUE:
0S/07/12 PROGRESS
0S/28/12 PERMIT
JOS* 12023
SHEET:
S2.2
ti
NI\
7st
4
.1/4
6
•
NA\
t
EXISTING STRUCTURE
6,,
sit
"1/4.
„1/2.
3
s
r
1/4
■
tt
POND
a
u
rig
6t6
o
EXISTING
RESIDENCE
EXISTING STRUCTURE
r
,n
gee
1i
EXISTING GARAGE
11
4
•
ye w iidimpearrir 'as
GREEK
SITE PLAN
SCALE: Ift a 60'-0" on 22° x 94"
SCALE: I° a 120'-0" on 11' x 11"
1
4
•
PROPERTY LINE
i
5.K. PEIGHTAL ENGINEERS
PROVIDES THE A -SERIES
SHEETS IN A DRAFTING ROLE
ONLY, AT THE OMER'S
DIRECTION. A -SERIES
DOCUMENTS INDICATE DESIGN
BY THE OMER. 5,K. PEIGHTAL
ENGINEERS WAIVES ANY AND
ALL RESPONSIBILITY AND
LIABILITY FOR PROBLEMS
WHICH ARISE FROM FAILURE TO
FOLLOW THESE PLANS AND THE
DESIGN INTENT THEY CONVEY,
OR FOR PROBLEMS WHICH
ARSE FROM OTHERS' FAILURE
TO OBTAIN AND/OR FOLLOW
GUIDANCE OF 5.K. PEIGHTAL
ENGINEERS WITH RESPECT TO
ANY ERROR5, OMISSIONS,
INCONSISTENCIES, AMBIGUITIES,
OR CONFLICTS WHICH ARE
ALLEGED.
S'KPE
S K PEIGHTAL ENGINEERS
298 PARK AVENUE #301
BASALT, COLORADO 81621
PHONE: (970) 927-9510
OLSON ADDITION
5648 COUNTY ROAD 243
GARFIELD COUNTY, CO
ISSUE:
08/28/12 PERMIT
JOB* 12023
SHEET•
A0.1
OPEN TO
BELOW
OPEN TO
BELOW
I oILS laid/lc/opt/5 c L _ .3.S per
to r GC '► uirecMBwTI'j
Sec P/ter /4f//1dotopi/ #32
C o. A/,'kn izur/c m6nA /44
eI/s7'/ty a'2eMJ1 p s .
X
NEW GUEST
BATHROOM
NEW
PANTRY
06
GUEST
BEDROOM
05_.
1
STONE VENEER
HALLWAY
I
NEW ENTR1�
FOYER I
Dt l l
WOOD STORAGE
HD ngE
E1
NOE:
NEW KITCHEN LAYOUT
PER INTERIOR DESIGNER
KITCHEN
4
STONE VENEER
U 42
PROPOSED MAIN FLOOR PLAN
SCALE: 1/4" = I'-0 on 22" x 54"
SCALE! I/8' = I'-0 on II' x 11"
NEW WI
EXISTING WALL TO REMAIN
NEW WALL
VERIFY ALL NEW WINDOW
SIZES, SILL WEIGHTS AND
OPERATION WITH INTERIOR
DESIGNER.
NEE:
OWNER TO COORDINATE WITH
BUILDER TO DETERMINE SPECIFIC
FIXTURES, FINISH MATERIALS,
DOORS AND WINDOWS.
S.K. PEISHTAL ENGINEERS
PROVIDES THE A -SERIES
SHEETS IN A DRAFTING ROLE
ONLY, AT THE OWNERS
DIRECTION. A -SERIES
DOCUMENTS INDICATE DESIGN
BY THE OWNER. 5K PEIGHTAL
ENGINEERS WAIVES ANY AND
ALL RESPONSIBILITY AND
LIABILITY FOR PROBLEMS
WHICH ARISE FROM FAILURE TO
FOLLOW THESE PLANS AND THE
DESIGN INTENT THEY CONVEY,
OR FOR PROBLEMS WHICH
ARISE FROM OTHERS' FAILURE
TO OBTAIN AND/OR FOLLOW
GUIDANCE OF 5.K. PEIGHTAL
ENGINEERS WITH RESPECT TO
AM' ERRORS, OMISSIONS,
INCONSISTENCIES, AMBIGUITIES,
OR CONFLICTS WHICH ARE
ALLEGED.
SKP'E
S K PEIGHTAL ENGINEERS
298 PARK AVENUE #301
BASALT, COLORADO 81621
PHONE: (970) 9274510
OLSON ADDITION
5648 COUNTY ROAD 245
GARFIELD COUNTY, CO
ISSUE:
08/28/12 PERMIT
JOE3# 12023
SHEET:
A1.1P
L
STANDING SEAM METAL
ROOFING TO MATCH EXISTING
GUTTER AND D• - • BY OTHERS.
TYPICAL A5 I GATED. VERIFY TO
DISCHARGE MI , 101-0' AWAY FROM
BUILDING PER SOILS ENGINEER.
1212
1212
N
r -
I
I
H
{
4.75,12
4
PROPOSED ROOF PLAN
SCALE: I/4° = I'-0 on 22" x 34'
SCALE: I/' = Ib on 111 x 11°
1
1-
GUTTER AND DOWNSPOUT BY OTHERS.
TYPICAL AS INDICATED. VERIFY TO
DISCHARGE MIN. 101-0' AWAY FROM
BUILDING PER SOILS ENGINEER
FACE OF WALL BELOW
i
5,K. PEIGHTAL ENGINEERS
PROVIDES THE A -SERIES
SHEETS IN A DRAFTING ROLE
ONLY, AT THE OWNER'S
DIRECTION. A -SERIES
DOCUMENTS INDICATE DESIGN
BY THE OWNER. 5.K. PEIGHTAL
ENGINEERS WAIVES ANY AND
ALL RESPONSIBILITY AND
LIABILITY FOR PROBLEMS
WHICH ARISE FROM FAILURE TO
FOLLOW THESE PLANS AND THE
DESIGN INTENT THEY CONVEY,
OR FOR PROBLEMS WHICH
ARISE FROM OTHERS' FAILURE
TO OBTAIN AND/OR FOLLOW
GUIDANCE OF 5.K. PEIGHTAL
EN611kEER5 WITH RESPECT TO
ANY ERROR5, OMISSIONS,
INCONSISTENCIES, AMBIGUITIES,
OR CONFLICTS WHICH ARE
ALLEGED.
S'K'P'E
S K PEIGHTAL ENGINEERS
298 PARK AVENUE #301
BASALT, COLORADO 81621
PHONE: (970) 927-9510
OLSON ADDITION
5648 COUNTY ROAD 243
GARFIELD COUNTY, CO
ISSUE:
08/28/12 PERMIT
,1084* 12025
SHEET:
A1.2P
-PWOOD
100T. ' 0LY"
I
T I I
I 1
1 I I
I
I
I I
I III
II
[II I
I I I
I
1
7I
I
SKPE
1
OLSON ADDITION
5648 COUNTY ROAD 243
GARFIELD COUNTY, CO
I I
08/28/12 PERMIT
I
)
1r
)1
)1
II II III
IIIIIII
I I I 1 I
I 1 I
1 I I
1 I 1 I
1 I I
i
1
EXISTING SOUTH ELEVATION
SCALE: 1/4" = I'-0 on 22" x 54"
SCALE: I/8" = I'-0 on II" x 11"
EMI
MATCH EXISTING
EXISTING 'D' L06 WALL
STONE VENEER. GAP
FLASHING BY OTHERS.
12
12
2
lb
T'
40 A
/, j dit = j\I Of
// ate. /a•' =a�
12
12
4.15
ott
�•9•
a
is°� n
/
RIDGE LOCATED TO ALLOW NEW RIDGE
BEAM TO BEAR ON EXISTING BEARING
WALL AT GRID 'C'. ADJUST ROOF
SLOPE AS REQUIRED TO MEET RIDGE
AND FASCIA ELEVATIONS.
FASCIA ELEVATION VLF.
TO MATCH EXISTING
)I
1)
u
)
STONE VENEER
FROFQSED SOUTH ELEVATION
SCALE: I/4" = 11-0 on 22° x 34"
SCALE: I/8" = I'-0 or 11" x 11"
STONE VENEER. GAP
FLASHING BY OTHERS.
EXISTING WOOD SIDING
S.K. PEIGHTAL ENGINEERS
PROVIDES THE A -SERIES
SHEETS IN A DRAFTING ROLE
ONLY, AT THE OWNER'S
DIRECTION. A -SERIES
DOCUMENTS INDICATE DESIGN
EY THE OWNER, S.K. PEIGHTAL
ENGINEERS WAIVES ANY AND
ALL RESPONSIBILITY AND
LIABILITY FOR PROBLEMS
WHICH ARISE FROM FAILURE TO
FOLLOW THESE PLANS AND THE
DESIGN INTENT THEY CONVEY,
OR FOR PROBLEMS WHICH
ARISE FROM OTHERS' FAILURE
TO OBTAIN AND/OR FOLLOW
GUIDANCE OF S.K. PEIGHTAL
ENGINEERS WITH RESPECT TO
ANY ERRORS, OMISSIONS,
INCONSISTENCIES, AMBIGUITIES,
OR CONFLICTS WHICH ARE
ALLEGED.
SKPE
S K PEIGHTAL ENGINEERS
298 PARK AVENUE #301
BASALT, COLORADO 81621
PHONE: (970) 927-9510
OLSON ADDITION
5648 COUNTY ROAD 243
GARFIELD COUNTY, CO
ISSUE:
08/28/12 PERMIT
JQS 12023
SHEET
A2.2