HomeMy WebLinkAboutPlansAPPROVED SUBJECT TO NOTED EXCEPTIONS & INSPECTIONS GARFIELD COUNTY BUILD 1 G DEPAR'1ENT pat. 7 BY.�._. LD COPY No, INSPECTION WITHOUT T! ESE PLANS ON SITE Pie of K R M CONSULTANTS, INC. P.O. Box 4572 Vail, Colorado 81 B59 970-949-9991 FAX 949-1577 TO: Blu Sky Restoration ATTENTION: Chris Kintner PROJECT: 226 Cnty Rd 126 Deck FIELD REPORT DATE: 03/22/11 ARRIVE: 7:45am DEPART: 8:15am WEATHER: cldy/cool JOB NUMBER: 1103-09 PRESENT AT SITE: Chris, Homeowner STATUS OF COMPLETION: N/A On March 22, 2011 I visited the above -referenced site to observe the damaged deck joists (north deck) reportedly caused by sliding snow from the roof above. I was told that the original house and deck(s) were built in the 1980's and that an addition had been constructed in 2002. However, no construction drawings were observed during the site visit. I observed the framing for the north deck, and specifically, the damaged joists, which were located where there is a jog in the deck framing (I'm told that this was where the new deck was added in 2002). The deck framing consists of 2x8 joists spaced at 16 inches on center. These joists hang off of a 2x ledger at the house structure, but appear to be end - nailed to a single 2x8 rim at the edge of the deck. Four log columns appear to precariously support the deck framing, although no actual beam is bearing on these columns. Blocking was installed between two joists to provide some general bearing at these columns, but again, no actual beam supports were constructed. There were four damaged 2x8 joists adjacent to the jog in the deck framing that were moderately to severely cracked from the impact of the sliding snow. The rim beam that supports these joists appeared to have also shifted lower where it attaches to the newer deck. The deck beam supporting this rim beam also appears to have become partially dislodged on one end, near the concrete pier. ,�Yy Each of the four damaged deck joists shall be reinforced/replaced with a 1 3/< x 7 1/4 LVL (16 inch maximum spacing). Hangars shall be installed on each end of these joists as shown on the attached plan view. The 2x rim supporting these joists shall be reinforced with an additional (2)-2x8's for a total of (3)-2x8's. The adjacent beam shall also be reinforced with an additional (2)-2x8's, and this beam shall be anchored to the concrete pier and the log column per attached plan. In addition to the damaged area mentioned above, the remaining deck structure observed does not meet current design load standards as constructed. A beam should be added over each of the log columns, the rim beams should be reinforced, and hangars should be added to each joist as shown on the attached plan view. Please do not hesitate to call with any questions or to discuss this report further. KRM Consultants, Inc. SIGNED: Tim D. Hennum, PE REVIEWED: 167 VP;5.- 25 (I <� o°rne r'7i1`:1 COPY TO: R imeimot Seel-eAfr3Pd pinta T (2)-3/4"0 EXP. ANCH.'s (4" PEN. IN CONC.) ADD (2)-2x8 TO EXSTG. 2x8 RAISE RIM/DECK TO ALIGN W/ ADJACENT DECK & ADD (2)-2x8 NEW 13/4x7Y4 LVL's CRACKED 2x8's SIMPSON HU26 3 iii 1- SIMPSON TYP1 4_ HU7, T ADD (2)-2x8 TO EXSTG. 2x8 RIM T ADD SIMPSON LUS26, 7—CONTACT ENGR. FOR \\� CONN.'s IF BM.'s ARE INSTALLED G \ Ca \\ ADD (3)-2x8 OR (2)-113/4x0Y4 LVL C9 LOG COL 's, TYP. 7 - EXSTG. 2x8's @ 16" 0.C. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 (2)-s/a"o LAGS (5" MIN. PEN. IN LOG) DECK FRAMING PLAN 1 1 1 1 1 1 1 1 -T T i 1_L_J I_LL 1_ L j -4-1- - 4 t 1 1 1 1 1 1 1 1 1 1 SCALE: 1 4 DESIGN CRITERIA: Deck Live Load (Snow) Deck Dead Load 40 psf 15 psf 1. Existing construction is indicated thus ( ), new construction is indicated thus 2. Laminated veneer lumber (LVL) shall have the following minimum properties: 1. Flexural stress 2600 psi 2. Modulus of elasticity 1,900,000 3. Tension porollel to grain ---- 1850 psi 4. Compression parollel to grain - ---- 2310 psi 5. Compression perpendicular to groin (parallel to glue line) 750 psi 6. Horizontal shear 285 psi psi ) See /9// A,e7,1zsem'/9/ �a��M� 4„ ice• 2 (� e e•_ 6 Z ,- ,..o zz 8 a°• P - a � a t m a 0 P 15.-k o a o t a "' 53 m8 Y- a'� P McDERMOTT DECK 226 COUNTY ROAD 126 GARFIELD COUNTY, COLORADO designed by TON Morn by MTN *sued ISSUE 03/31/11 sbee9 S1 JOB #1103-09 (3 2x 10 (2)-3/4"0 EXP. ANCH.'s (4" PEN, IN CONC.) ADD (2)-2x8 TO EXSTG. 2x8 RAISE RIM/DECK TO ALIGN W/ ADJACEN T DECK & ADD (2)-2x8 NEW 2x8's © 16" 0.C. © CRACKED 2x8's tC") cTh DROI4PED1 C.; & F 1 (3)'-2X1'0 (DOPED) I Aii-kr-i .e_.p.)/1-lit nivievri- # 32 CCC) A1/71/W1 OVA' detdilev45 /4 exinvi4 sTitac-iy,t, ye NOTE: I T L DING IS ANTICIPATED FROM HUG E ROOF, USE 13/4x7314 LVL's G 0)-.2x, 0 (DROPPED O m— APPROVED SUB,TECT 10 NOTED? . EXCEPTIONS & INSPECTIONSC, GARFIELD COUNTY' WILD G DEP tiate 'FIELD COPY NO INSPECTION WITIMPT THESE PLANS ON SEW PAW c 0 (3)-2x101 (DROPPED) 7-1 - SIK,+ PSON TS18 EA SD- -- SIN/ PSON LUS28, TYP. NOTCH! EXSTG. 11.00 COL. FOR NEW bm. EXSTG. 2x8's © 16" 0.C. I 11 1 I I 1 1 1 I 1 I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I 1 1 1 1 1 ! PEN. IN LOG) OW 34J_Deric ledger per rgc, g.5-0z.z,i, ihvbi L0441 Zoo, pet.P2C ThOZE 50) (2)—%"0 LAGS (5" MIN. er AWL./ Chili 9 DECK FRAMING PLAN SCALE: 1 /4" = 1'-07 FAr7444-ev5 Yt 41W-1—cc' u per DESIGN CRITERIA: Deck Live Load (Snow) Deck Dead Load 40 psf 15 psf 1. Existing construction is indicated thus ( — 2. Laminated veneer lumber (LVL) 1. Flexural stress 2. 3. 4, 5. 6. Modulus of elasticity ew construction is indicated t h u shall have the following minimum properties: 2600 ps 1,900,00 Tension parallel to grain Compression parallel to grain Compression perpendicular to Horizontal shear 1850 psi 2310 psi grain (parallel to glue line) 750 psi 285 psi 5bud-mals entoz414-kred psi dal) i4q Repot gegaire engineered hprizenixi, LtS,-6ta WO mu 05903 03 Ire0 t60-6.6 (005) US' 1(08 Od P40 15....,a0u.Snua DNI "SINY.1.1115N00 rev McDERMOTT DECK 226 COUNTY ROAD 126 GARFIELD COUNTY, COLORADO designed drown rheded issued by TDH by MTN by ISWE.... 03/31 it t sheet S 1 JOB #1103-09 NOTE: LOG COL. MAY BE NOTCHED ON EITHER SIDE FOR NEW BEAM. ADD 2x BLKG Q BRG. OVERFRAMING & -\ WATERPROOFING BY OTHERS (2)-3/4"0 THRU-BOLTS NEW BEAM PER PLAN EXSTG. DECK JOISTS EXSTG LOG COL. NOTCH FOR NEW BEAM AT TOP SCALE: 3/4" = 1'-0" KRM CONSULTANTS. INC. 111rucfurol engineering end Casio, P.O. BOX 4572 PH, (970) 9a9-9391 VAR, C0 BMW FAX (970) 949-1577 McDERMOTT DECK 226 COUNTY ROAD 126 GARFIELD COUNTY, COLORADO designed drown checked issued by TOH by SCS by TOH ISSUE 03/31/11 REVISED 07/11/11 sheet S2 JOB #1103-09