Loading...
HomeMy WebLinkAboutApplication-PermitGarfield County No. I· 10808 I Building & Sanitation Department 108 8th Street, Suite #401 Glenwood Springs, Co. 81601 Office 945-8212 Inspection Line 384-5003 JobAddress: J,'780 (_R. (1"3 ~ CoffCo;>...3 Locality: ~-,pi :ls '73 - / ~ 3,... (Jl) ~ S 7S Use of Buildin~ -6::,,5 (F' j? ~ t»f 'f Co\) .. ~ Owne" ;z-~ I ~ , 1 ·Contractor: ~ Amount of Permit: Ito lfg.q 3 Date: 2 3 10 11 GARFIELD COUNTY BUILDING PERMIT APPLICATION 108 gth Street, Suite 401, Glenwood Springs, Co 81601 Phone: 970-945-8212/ Fax: 970-384-3470 I Inspection Line: 970-384-5003 www.garfield~oounty.com Lot No: I 3 ?Rt: P. If 1\:.4 3 Block No: bGs 0 SubdJ Exemption: Class of Work: ' oNew o Alteration )(Addition Garage: Septic: oAttached 0 Detached o!SDS o Community . 12 Driveway Permit: \\J f 1.\ Owners valuation of Work: $)5o~~ .~ NOTICE Authoritv. This application for a Building Permit nmst be sighed by_ the Owner of '!he property, described above, or an authorized agent If the signatoro below is not that of the Owner, a separate lette:r of authority, signed by the Owner, must be provided with this AWficat:ioa I ge! A.......,s A Building Pennit cannot be issued without proof of legal and adequate ·access to the property for purposes of i.nspeaions by the Building Depmtment Other .Permit&. Multiple separate permits may be required: (l) State Electrical Pemdt. (2) Comity 1SDS Permit, (3) another permit required for use on 1he~ identified above, e.g. State or County Highway/ Road Access or a State Wastewater Discharge Pennit. Void Pennit. A Building Permit becomes null and void if the wotk authorized is not cotQDHl1lced within 180 days of the date of issuance and if work is suspended or abandoned for a period of 180 days after c:.omtne'Dllellt CERTI.FICADON ' ·;I hereby certify that' I have read this Application and that 1he information contained above is true and oorrect. I m1derstand that the Building Department accepts the Application, along with the plans 3nd specifu:ations and other data _submitted by me or on my behalf(snbmittals); based upon my certification as to accuracy. Assuming completeness of the submittals and approval of1Jris Application. a Bwlding Penni!: will be issued granting permission to me, as Owner, to construct the strucfuro(s) and facilities detailed on the submittals reviewed by the Building J.)epartlrent. In considemtion of the issuance of the Building Pennit,l agree that I and my agCots will comply with provisions of any fedeml,. state or local law regulating '!he work and the Garfield County Building Code, ISDS regulations and applicable land use n:gulatioos (Cowrty Regulation(s)). I acknowledge that the Building Permit ma:y be suspended or revoked, upon notice fi:om the County, if the location, construction or use of the stmcture(s) andfitcilit.Y(ies), described above, are not in compliance with County Regulatioo(s) or any other applicable law. I hereby grant permission to the BuiJifing Department to enter the properly, descnDed above. to inspect the work. I further acknowledge that the issuance of the Building Permit does not prevent the Building Official fi:om: (I) rcquUing the correctioo of ef:rors in the submittals, if any, discovered after issuance; or (2) slopping c:cmstruction or use of the stmctore(s) or fucility(ies) ifscch is in violatioo of County Regnlation(s) or aoy other applicable JaW. ReView of this Application,. including submittals,. and inspectiOllS of the work by the Building Department do not constitute an acceptance of responst"bility or liability by the County of errors. omissions or discrepancies. As the Owner, I acknowledge that responsibility :fur compliance with federid, state and local laws and County Regulations rest with me and my aufuorized agmrt:s,. including without limitation my architect designer, engineer and/ or builder. I HEREBY ACKNOWLEDGE TIIAT l HAVE READ AND UNDERSTAND THE NOTICE & CER'FIFICATION ABOVE: OWNE~SIGNATURE ~ DATE STAFF USE ONLY Adjusted Manu home Fee: Mise Fees: The following items are required by Garfield County for a fmal Inspection: 1) A fmal Electrical Inspection from the Colorado State Electrical Inspector. 2) Permanent address assigned by Garfield County Building Department and posted at the structure and where readily visible from access road . . 3) A finished roof; a lockable building; completed ~xterior siding; exterior doors and windows installed; a complete kitchen with cabinets, sink with hot & cold rmming water, non-absorbent kitchen floor covering, counter tops and finished walls, ready for stove and refrigerator; all necessary plumbing. 4) All bathrooms must be complete, with washbowl, tub or shower, toilet, hot and cold running water, non-absorbent floors, walls finished, and privacy door. 5) Steps over three (3) risers, outside or inside must be must have handrails. Balconies and decks over 30" high must be constructed to all me and IRC requirements including guardrails. 6) Outside grading completed so that water slopes away from the building; 7) Exceptions to the OJJtside steps, decks, grading may be made upon the demonstration of extenuating circumstances., i.e. weather. Under such circumstances A Certificate of Occupancy may be issued conditionally. 8) A fmal inspection sign off by the Garfield County Road & Bridge Department for driveway installation, where applicable; as well as any final sign off by the Fire District, and/or State Agencies where applicable. A CERTIFICATE OF OCCUPANCY (C.O.) WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. A C.O. MAY TAKE UP TO 5 BUSINESS DAYS TO BE PROCESSED AND ISSUED. OWNER CANNOT OCCUPY OR USE DWELLING UNTIL A C.O. IS ISSUED. OCCuPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. I understand and agree to abide by the above conditions for occupancy, use and the issuance of a C.O. for the building identified in the Building Permit. DATE VALUATION FEE DETERMINATION Applicant Address Date ~FC::itz=si;:;mm~o:-:;n:;:s -..,..-'---------..,..--Subdivision .;;2":7::':80:-,C;;;R=:;.,;;;l.:;;;l3'---'--------Lot/Block _,1::..!7:.:./::c20::.:0:.:.8:.__~---'----'--Contractor Finished {Livable Area): Main Upper Lower Other Total Basement: Unfinished Square Feet Valuation Conversion of Unfinished to Finished Total Valuation Garage: Valuation Crawl Space Valuation Decks/ Patios Covered Open Valuation Type of Construction: Occupancy: Valuation Total Valuation 1237 sf sf sf sf X $74.68 1237 sf sf X $41.00 sf X $33.68 sf X $18.00 sf X $9.00 344 sf X $24.00 sf X $12.00 Commercial sf X sf X sf X sf X sf X sf X Eco-build 92,379.16 0.00 0.00 0.00 8,256.00 0.00 100,635.16 • GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS For SINGLE FAMILY DWELLING CONSTRUCTION Including NEW CONSTRUCTION ADDITIONS ALTERATIONS And MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. When reviewing a plan and it's discovered that required information has not been provided by the applicant, this will result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor shall be required to provide this information before the plan review can proceed. Other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. Any project with more than ten (10) occupants requires the plans to be sealed by a Colorado Registered Design Professional. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following checklist prior to and during design. Applicants are required to indicate appropriately and to submit the completed checklist at time of application for a permit. Plans to be included for a Building Permit, must be on drafting paper at least 18"x24" and drawn to scale. Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with 1 decks, balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line and original grade. A section showing in detail, from the bottom of the footing to the top of the roof, including re-bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing. insulation, sheeting, house-rap, (which is required), siding or any approved building material. Engineered foundations p:1ay be required. A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be designed to withstand a40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. wind speed, wind exposure B or C, and a 36 inch frost depth. All sheets to be identified by number and indexed. All of the above requirements must be met or your plans will be returned .. All plans submitted must be incompliance with the 2003 IRC. I. Is a site plan included that identifies the location of the proposed structure or addition and distances to the property lines from each corner of the proposed structure(s) prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Properties with slopes of 30% or greater must be shown on the· site plan. (NOTE Section: 1 06.2) Any site plan for the placement of any portion of a structure within 50 ft. of a property line and not within a previously surveyed building envelope on a subdivision final plat shall be prepared by a licensed surveyor and have the surveyor's signatirre and professional stamp on the drawing. Any structure to be built within a building envelope of a lot shown on a recorded subdivision plat shall include a copy of the building envelope as it is shown on the final plat with the proposed structure located ~in the envelope .. 2. Does the site plan also include any other buildings on the property, setback easements and utility easements? Please refer to Section 5.05.03 in the Garfield County Zoning Resolution if the property you are applying for a building permit on is located on a corner lot. Special setbacks do apply. Yes (\D 3. Does the site plan include when applicable the location of the I.S.D.S. (Individual Sewage Disposal System) and the distances to the property lines, wells (on subject property and adjacent properties), streams or water courses? Yes 1'\D 4. Does the site plan indicate the location and direction of the County or private road accessing the property? 2 ®'----- 5. Are you aware that prior to submittal of a building permit application you are required to show proof of a driveway access permit or obtain a statement from the Garfield County Road & Bridge Departtnent stating one is not necessary? You can contact the Road & Bridge Department at 625-8601. Yes §2 6. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the IRC or per stamped engineered design? @~---- 7. Do the plans indicate the location and size of ventilation openings for under floor crawl ~s and the clearances required between wood and earth? 8. Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces and soffits? @ ___ _ 9. Do the plans include design loads as required by Garfield County for roof snow loads, (a minimum of 40 pounds per square foot up to & including 7,000 feet above sea level), floor ~? 10. Does the plan include a building section drawing indicating foundation, wall, floor, and roof construction? ~-------- 11. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or joists or trusses? CJ'--·-- 12. Does the building section drawing or other detail include the method of positive connection ~l columns and beams? · 13. Does the elevation plan indicate the height of the building or proposed addition from the undisturbed grade to the midpointbetween the ridge and eave of a gable or shed roof or the ~fa flat roof? (Building height measure:nent usually not to exceed 25 feet) ~ (\I<... C., 1'~\,¢ ~ l'P~ \I v""-. 14. Does the plan include any stove or zero clearance fireplace planned for installation including 3 make and model and Co orado Phase II certifications or phase II EPA certification? Yes ~o~----~----~ 15. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the IRC?;:::., Yes ~------------- 16. Does the plan include a window schedule or other verification that egress/rescue windows ~sleeping rooms and/or basements comply with the requirements of the IRC? ~ No ____________ _ 17. Does the plan include a window schedule or other verification that windows provide natural ~and ventilation for all habitable rooms?. ~ No ____________ ~ 18. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety glazing for these areas? ~ No ____________ __ 19. ls the location of all natural and liquid petroleurr gas furnaces, boilers and water heaters _t:I.~>i/:·ted on the plan? No--~-- 20. Do you understand that if you are building on a parcel of land created by the exemption process or the subdivision process, are building plans in compliance with all plat notes ...,L.:::l!i~or covenants? Yes No __ __.: ____ _ 21. Do you understand that.if you belong to a Homeowners Association (HOA), it is your responsibility to obtain written permission from the association, if required by that association, prior to submitting an application for a building permit? The building permit application will be accepted without it, but you run the risk of the HOA bringing action to enforce the covenants, which can result in revocation of permit issued. Additionally, your Plan Review fee is not refundable if the plans have been reviewed by the Building Department R ·or to any action by the HOA that requires either revocation or substantial modificati the plans. Yes __________ _ 22. tial structure on the parcel? .,._..'1-----If no-Explain: AJJ ,:L,-110 23. e two (2) complete sets of construction drawings been submitted with the application? Yes-l------- 4 24. Do you understand that the minimum dimension a home can be on a lot is 20ft. wide and ~No __ 25. Have you designed or J:§d this plan designe£1 while considering building a!'ld other ~ruction code requirements? ~No ____ _ 26. Do your plans comply with all zoning rules and regulations in the County related to your .r-..;"'-~erties zone district? Yes No ------ 27. oes the plan accurately indicate what you intend to construct and what will receive a final ction by the Garfield County Building Department? No ____ _ 28. Do you understand that approval for design and/or construction changes are required prior e application of these changes? Yes No ____ _ 29. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application submittal and that you will be required to pay the "Permit Fee" as well as any "Road Impact" or "Septic System" fees required, at the time you pick up your · ing permit? No ____ _ 30. Are you aware that you must call in for an inspection by 3:30 the business day before the requested inspection in order to receive it the following business day? Inspections will be made from 7:30a.m. to 3:30p.m. Monday through Friday. Inspections are to lied in to 384-5003. No ____ ___c_ 31. Are you aware that requesting inspections on work that is not ready or not accessible will tin a $50.00 re-inspeciion fee? Yes No _______ _ 32. Are you aware that you are required to call for all inspections required under the IRC inc:luding approval on a final inspection prior to receiving a Certificate of Occupancy and /occunancy of the building? (>o/ No . . 5 33. Are you aware that the Permit Application must be signed by the Owner or a written authority being given for an Agent and that the party responsible for the project must comply I'Y!..r· tk the IRC? No _____ _ 34. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups, unless you ·as the homeowner are performing the work? The license number of the person performing the work will be ttetmn:· ed at time of applicable inspection. Yes · No ______ _ 35. Are you aware, that on the front of the Building Permit Application you will need to fill in the Parcel/Schedule Number for the lot you are applying for this permit on prior to submittal Arl<tilding permit application? Your attention in this is appreciated. 36 .. No Do you know that )ill:e~~l. fire district may require you to submit plans for their review of fire safety issues. Yes No (please check with the building departrnen ut this requirement) 37. Do you understand that if you are planning on doing any excavating or grading to the property prior to issuance of a building pennit that you will be required to obtain a grading ~ 38. Are you aware that if you will be connecting to a public water and/or sewer system, that the ta fees have to be paid and the connections inspected by the service provider prior to the ce of a Certificate of Occupancy? . . s I hereby acknowledge that I have read, understand and answered these questions to the best of my ability. ~ --l9§=. ""~ ]2.--S~o-r s;gn;:eoflSlwner Date Phone: __ 0_,_14_,_:'>"----l,_\Cj,_,.(o"-'\ ___ ( days); __________ .(evenings) Notes: If you have answered "No" on any of the questions, you may be required to provide this 6 information at the request of the Building Official prior to beginning the plan review process. Delays in issuing the permit are to be expected. Work may not proceed without the issuance of a permit. If it is determined by the Building Official that additional information is necessary to review the application and plans to determine minimum compliance with the adopted codes, the application may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review, delay in issuance of the permit or delay in proceeding with construction. Bpminreq November2006 · 7 GARFIELD COUNTY BUILDING REQUIREMENTS Codes: 2003 IRC, IBC, IFGC, IMC, IPC, Setbacks: Check subdivisions and zone district for setback requirements. Snowload (measured at the roof): 40PSF up to 7000ft. elevation. Seismic design category: B SOP SF 7001 to 8000ft. 7 5PSF 8001 to 9000ft. 100PSF 9001 to 10000ft. Weathering probability for concrete: Severe Termite infestation probability: None to slight Wind speed: 90mph Decay probability: None to slight Wind Exposure: B or C (see section R301.2.1.4) Frost Depth: 36in. to 8000ft. elevation. 42in. 8001 and above. Winter Design Temperature: Minus 2 to 7000ft.; minus 16 over 7000ft. elevation. Air Freezing Index: 2500deg F-days to 7000ft.; over 7000ft. to be determined by Building Official. Ice shield under-layment required. Mean Annual temp.: Variable Insulation: Maximum glazing U factor: 0.50 Minimum R-Values: • Ceilings/roofs R values are: R-30 stick built structures. R-38 log construction and steel rafter construction. • Walls R values are R-19 wood frame; R-19 cavity R-3 sheathing steel studs. • Floors R-values are R-19. • Basement wall R-values are R-1 0 bel'ow grade, R-19 above grade. • Slab perimeter R-value and depth is R- 10/36in. • Crawl space wall R-values are R-10 below grade and R -19 above grade If floors over crawl spaces are not insulated, the crawl space walls must be insulated. Basement wall must be insulated to frost depth. Common walls garage to house must have R-19 insulation. Common ceiling/floor garage to house must have R-19. Take precautions to protect plumbing in these areas. PLAN REVIEW CHECKLIST App licant_--lf-l-, --"t'--'Z.c;.-~5..LJ..'-'-V'1=M"-'d'1'\4'-'-"'"- /uilding LEngineered Foundation V Driveway Permit ,F.Jct..,.+'-"l.y ~urveyed Site Plan ·~ ':r<' t t}z,_septic Permit and Setbacks ~Grade/Topography 30% . =Attach Residential Plan Review List ~Minimum Application Questionnaire /subdivision Plat Notes ~Fire Department Review 1 / jaluation Determination/Fees _/_RReecd Line Plans/Stamps/Sticker ~Attach Conditions JLApplication Signed ~Plan Reviewer To Sign Application -LL_Parcel/Schedule No. ~ 40# Snowload Letter-Manf. Hms. GENERAL NOTES: Date. _ _J..)_._Z_-_I,_].~__-.=.0-\l---' Planning/Zoning _Lrroperty Line Setbacks ~ 5<1 ( 3 .....,., I ~30ft Stream Setbacks '- ~loodP!ain Lsuilding Height ~ning Sign-off ~ad Impact Fees _0oA/DRC Approval 4de/Topography 40% _,__LPlanning Issues vSubdivision Plat Notes _«:__ No. -;~----1/'-"0~g::;__D_Il __ _ Assessor's Parcel No. ;2393 ~ (03-(Jl)-3?5 ---.···. '· Date------- ' B~LDIN~ PER~IT _CARD Job Address d:'1 %'b c~ \( ~ ~~ ~ glfo;l-3 Owner~~o= AddressJ-780 Cti.-.(13 C~th~r?e#~ ContractO&iX:\j]L Addressf.o.@Y,3oo~ ~c;,~;~e # .. · 3'1q. 75sc.. Setbacks: Front Rear ~ RH LH Zoning ~ b:, SfF ~ ~ fCJH' INSPECTIONS Soils Test W/ ~ · ~ Weatherproofing __________ _ Footing f/"'3f..tjf/ ~ Mechanical z; Foundation .;) ·I¥ · 0 i'9?P--Electrical Rough (State)----"'• --,---r/'------ Grout ~ Electrical Final (State)·:;:;-::-;::::~;-:::-:~-:=::::===- Underground Plumbing 3 -,-t'lr~ ...p-Final ltf~:Jc-eJ8 /Checklist Completed?_. __ _ Rough Plumbing '!1::2:£.:0 ?"~ . . , .·· Certificate Occupancy # -------- Framing -s--l-0 &3&?4 :z.:;;tiA~, .A£~£/ . Date--,--:-.-------- Insulation 5"·/J-o'[(~ 7 Septic System #...,:t,..2"- 1 f-I.Lif,__ _______ _ Roofing Date ----------- Drywall -!(.;<f·t:~-~ ~ Finai ___ --.:---,--,------- Gas Piping <;-Ls="o~ Other &(_A .t AlfAAm 1-v'Y'4 NOTES • (continue on back) ' COUNTY OF GARFIELD -BUILDING DEPARTMENT CORRECTION NOTICE 108 8th St., Suite 401 Glenwood Springs, Colorado Phone (970) 945-8212 Job located at :;2 7&:? ~£ /13 PermitNo. __ ~/~o~~~·~C?~·~zr~-------------------------- I have this day inspected this structure and these premises and found the following corrections needed: ).1( Call for Re-lnspection ~$50.00 Re-lnspection Fee must be paid prior to Re-lnspection You are hereby notified that the above correction must be inspected before covering. When correction(s) have been made, call for inspection at 970-384-5003. COUNTY OF GARFIELD -BUILDING DEPARTMENT CORRECTION NOTICE 108 8th St., Suite 401 Glenwood Springs, Colorado Phone (970) 945-8212 Job located at ,67!10 d//3 Permit No. 1 &i $'0 8-- I have this day inspected this structure and these premises and found the following corrections needed: )!:tan for Re-lnspection D $50.00 Re-lnspection Fee must be paid prior to Re-lnspection You are hereby notified that the above correction must be inspected before covering. When correction(s) have been made, call for inspection at 970-384-5003. Date <f-JgcJ-6() 20 r--- Building Inspector ~~;;::::::::::::=~;=--~ Phone (970) 945-8212 COUNTY OF GARFIELD -BUILDING DEPARTMENT CORRECTION NOTICE 108 8th St., Suite 401 Glenwood Springs, Colorado Phone (970) 945-8212 Job located at ;() 8'0 C !Z/13 PermitNo.~~~~~~~o~z~·----------------------------- I have this day inspected this structure and these premises and found the following corrections needed: )(Call for Re-lnspection 0 $50.00 Re-lnspection Fee must be paid prior to Re-lnspection You are hereby notified that the above correction must be inspected before covering. When aorrection(s) have been made, call for inspection at 970-384-5003. Date ~-.).5--0?" 20 ____ _ Building Inspector ~~/?/@-·· Phone (970) 945-8212 COUNTY OF GARFIELD -BUILDING uc.-...... c 108 8th St., Suite 401 Glenwood Springs,> Phone (970) 945-8212 I have this day inspected this structure and thE~SEf premises and found the following corrections ne,ed'~·' Fee must be to You are hereby notified that the above correction must be before covering. When correction(s) have been made, call for inspection at COUNTY OF GARFIELD * BUILDING DEPARTMENT CORRECTION NOTICE 108 8th St., Suite 401 Glenwood Springs, Colorado Phone (970) 945-8212 Job located at 2 7 & 0 Permit No. /!25 0 gv ' I have this day inspected this structure and these premises and found the following corrections needed: ( o/J / q'AAIO i?A /t. ,CAf;:Js A/£KO w ICJCJY/<.AI TCi ~o57'"..S ~o()r £/JGE At: t/e/!C/( /?117o Call for Re-lnspect1on 0 $50.00 Re-lnspection Fee must be paid prior to Re-lnspection You are hereby notified that the above correction must be inspected before covering. When torrection(s) have been made, call for inspection at 970-384-5003. Date 2-/ 20 (!'.) g Building Inspector ~ ~¢> , Phone (970) 945-8212 INSPECTION WILL NOT BE MADE UNLESS THIS CARD IS POSTED ON THE JOB 24 HOURS NOTICE REQUIRED FOR INSPECTIONS BUILDING PERMIT GARFIELD COUNTY, COLORADO Date lssued •. Y,.f/.Q8. .... Zoned Area ...••..••...•.•.•...•.••..•.•.. Permit No ..• t.~K.. ....... . AGREEMENT In consideration of the issuance of this permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building Inspector and IMMEDIATELY BECOME NULL AND VOID. fo 00 I (.c.) (Of/. Setbacks. Front Side Side Rear This Card Must Be Posted So It is Plainly Visible From The Street Until Final Inspection. ~ 97c?-9.:>.7-031? INSPECTION RECORD Footing f ~ ~ 1-() "6 r!Jt-vil Driveway Foundation ,2 . ) 'I· o£ :f?;7r:7--A/IP Underground Plumbing 3-s-o,;;~ Insulation _")' /:3 -,pg ~ Rough Plumbing tf-::<6" '</iS~ Drywall S• I'T· d --< Chimney & Vent 9-3"-&ff~ Electric Final (by State lnsp f'z, Gas Piping '1-/o:"'Of>~ Final '1-3o--~·~ Electric Rough (By State lnsp~ p;,e. Septic Final ,;;81 Framing S..i-03'·~ 7&0,~ m/:,;:;,' Notes: (To include Roofin place and Win:fo'ws ec; ~ra.'! r!h and Doors installed). ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING- WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR A)lOVE GROUND. THIS PERMIT IS NOT TRANSFERABLE For Inspections Call384-5003 108 8th Street Glenwood Springs, Colorado APPROVED DO NO'f DESTROY THIS CARD Date (101o&Y 1 ~Wfot.~·C.c' ~LACED 0 SIDE-CO~ WI)H CLEAR PLASTIC f;>q ·-------, ' ' !._ --: LOS A.YIGOS RANCH ·----, GSRAm;;,---; ' ' ·------' ' ~..! , ____ , - ~---, ' ' a$vwk.., ,-------1.'""'--- , (.,p~mE~ ,::.. !._:___-i ...... .,_PJNONPEAKS : ' .. ' ' "! 112' I I I l\00 i~ I Parcel Detail Page 1 of 4 Garfield County Assessor/Treasurer Parcel Detail Information As!ie!i~or!Trei!Bl!rerf'mper\y"Sei!rc!:l I Assessor Subset _Qyej:y I AssessoLSales Search Clerk~Recor4exJ~.ecePtiollSeilr£h Basic B_uilding Characteristics I IM Information Parcel Detail I Value Detail Sales Detail I Residential/Cmnmercial ImJJrovement_Detail Land Detail I Photographs I Tax Area II Account Number II Parcel Number II Mill Levy I I 011 II R112001 II 239310300375 II 63.103 I Owner Name and Mailing Address !FITZSIMMONS, JUDITH G I j2780 COUNTY ROAD 113 I jCARBONDALE, CO 81623-9651 I Legal Description jSECT,TWN,RNG:10-7-88 DESC: A TR IN I jLOT 13. PRE:R111643 BK:0930 PG:0324 I jBK:0764 PG:0158 BK:0754 PG:0344 I IBK:1735 PG:314 RECPT:684258 BK:1707 I jPG:48 RECPT:678296 BK:1437 PG:693 I jRECPT:.621046 BK:l437 PG:691 I IRECPT:621045 BK:0930 PG:0329 I jBK:0827 PG:0460 I Location I Physical Address: 112780 113 COUNTY RD CARBONDALE! I Subdivision: I I Land Acres: 1113.83 I I Land Sq Ft: llo I Section II Township II Range I II II II http :1/www. garcoact. com! assessor/parcel.asp ?ParcelN umber=23931 030037 5 12/6/2007 Parcel Detail Page 2 of4 II 10 II 7 II 88 II Property Tax Valuation Information II Actual Value II Assessed Value I I Land: II 370,oooll 29,4501 I Im12rovements: II 706,o8oll 56,200J I Total: Jl l,o76,o8oJI 85,650J Sale Date: 111125/1995 Sale Price: l110o,ooo Basic Building Characteristics Number of Residential 1 Buildings: Number of Commllnd lo I Buildings: I Residential Building Occurrence 1 Characteristics I I TOTAL HEATED AREA: 113,560 I I ABSTRACT CODE·IISINGLE FAM.RES-• IMPROVEMTS I I ARCHITECTURAL STYLE: IJ1-STRY/BSM I I EXTERIOR wALL: IILOG I I ROOF COVER: JJPREFAB MET I I ROOF STRUCTURE: IIGABLE I I INTERIOR WALL: JJDRYWALL I I FLOOR: IICARPET I I FLOOR: IIHARDWOOD I I HEATING FUEL: IlGAS I I HEATING TYPE: IIHT WTR RAD I I STORIES: llsTORIES 1.0 I I BATHS: 13 I ROOMS: 16 I UNITS: 11 I BEDROOMS: 15 I YEAR BUILT: 111989 I http://www. garcoact.coml assessor/parcel.asp ?ParcelN umber=23931 03003 7 5 12/6/2007 Parcel Detail Tax Information I Tax Year II Transaction Type II Amount I I 2006 II Tax Payment: Second Half II ($2,258.46)1 I . 2006 II Tax Payment: First Half II ($2,258.46)1 I 2006 II Tax Amount II $4,516.921 I 2005 II Tax Payment: Second Half II ($2,268.26)j I 2005 II Tax Payment: First Half II ($2,268.26)1 I 2005 II Tax Amount $4,536.521 I 2004 II Tax Payment: Second Half ($2,146.96)1 I 2004 II Tax Payment: First Half ($2, 146.96)1 I 2004 II Tax Amount $4,293.921 I 2003 II Tax Payment: Second Half I ($1,804.98)1 I 2003 II Tax Payment: First Half II ($1,804.98)1 I 2003 II Tax Amount II $3,609.961 I 2002 II Tax Payment: Second Half II ($2,024.80)1 I 2002 II Tax Payment: First Half II ($2,024.80)1 I 2002 II Tax Amount II $4,049.601 I 2001 II Tax Payment: Second Half II ($2,036.03)1 I 2001 II Tax Payment: First Half II ($2,036.03)j I 2001 II Tax Amount II $4,072.061 I 2000 II Tax Payment: Second Half II ($1,783.44)1 I 2000 II Tax Payment: First Half II ($1,783.44)1 I 2000 II Tax Amount II $3,566.881 I 1999 II Tax Payment: Second Half II ($1. 1 s9 .21 )I I 1999 II Tax Payment: First Half II ($1,759.21)1 I 1999 II Tax Amount II $3,518.421 Top.oLP~ AssessorJ)f!ti!hi!se .... Se.<l'.:ch Options I Irc<lo\!JerJ)at<~hasc Scill:ch Qptions Clerk & Recorder Database Search Options Page 3 of 4 The Garfield County Assessor and Treasurer's Offices make every effort to collect and maintain accurate data. However, Good Turns Software and the Garfield County Assessor and Treasurer's Offices are unable to warrant any of the information herein contained. http: 1/www. garcoact. com/ assessor/parcel.asp ?ParcelN umber=23931 03003 7 5 12/6/2007