HomeMy WebLinkAboutApplication-PermitI Garfield County Building & Planning Department 108 8th Street, Suite #401 Glenwood Springs, Co. 81601 Office:970-945-8212 Fax: 970-384-3470 Inspection Line: 970-384-5003 Building Permit No. Parcel No: 2175-261-01-008 -- Locality: ·-·~ __ ]3eaver Creek Minor Sub9.ivision Rep L7 & L 10, Lot 1.:..::0:.:.A ___ _ Job Address: 6171 cr Rifte ------~-------~-------~------------··-----~-- Use of Building: Kitchen addition ·------··---··· Owner: Burner, Mark ----·--·-··--· -- Contractor: Fees: Plan Check: 365.92 Septic: Bldg Permit: 562.95 Other Fees: Total Fees: $ 928.87 ----- Clerk: ~~Q'_-·-Date: ~-=J~{)L_ I I 2 3 4 GARFIELD COUNTY BUILDING PERMIT APPLICATION 108 glh Street, Suite 401, Glenwood Springs, Co 81601 Phone: 970-945-8212 I Fax: 970-384-3470 I Inspection Line: 970-384-5003 www.garfield-countv.com Parcel No: 2\ 7 .\Z.{u 1 0 I() D 9, Job Address:{, \71 ( rOAlT'? l2nAt> ~2b /2_\I~I...G ci) fll(pro Lot No: lOA Block No: t_,~l Exemp~:c IAA ~Atli:O'f2_ :t;lc 'N.nl<. Address Ph: wrer. (1,, . c~/1,)(') WkPh; lA-o_v >~o17AJI.:::I(_ r~ \7\ "-' !1..120 ~I~'U' , C(?D-Z.JO -j(JJ7 5 Contractor: ~ Address Ph: £~ -{ AltPh: ~no -l.b \ -&<oo.r 6 Architect I Engineer: Address Ph: 1 AltPh: I -'no-9rr -2891 7 Sq. Ft. of Building: .'i 7 , Sq. Ft. of Lot: r <£<; Height No. ofFloors: . '-I "' ~ I 2. ., I " i 8 Use of Building: J( 1 1 J I IC..\-\1;/\] 9 Describe Worlc: p..,lt"l!'ili'i'i>\.\if;J M"'r'·rnAI 10 Class of Wmi<: ~~dition oNew o Alteration ll Garage: Septic: oAt1ached 0 Detaehed o!SDS oCommmtity 12 Driveway Permit: Owners valuation ofWorlc: $ !I'J0,/Y¥> NOTICE Autb01itv. This application for a Building Permit must be signed by the Owner of the property, described above, or an authorized agent If the signature below is not that of the Owner, a separate letter of authority, signed by the Owner, must be provided with this Application. LegAl Aecess. A Building Permit cannot be issued without proof of legal and adequate access to the property for purposes of inspections by the Building Depa:rtment Other Permits. Multiple separate pennits may be required: (I) State Electrical Permit. (2) Comity ISDS Permit, (3) another permit required for use on the property identified above. e.g. State or County Highway/ Road Access or a State Wastewater Discharge Permit. Void Permit. A Building Permit becomes null and void if the work authori7..ed is not ~mmenced within 180 days of the date ofissuance and if work is suspended or abandoned fur a period of 180 days after commencement · CERTIFiCATION :1 hereby certify that I have read this Application and that the information contained above is true and correct.. I uoden;tand that the Building Department accepts the Application. along with the plans 'and specifications and olher data submitted by me or on mybebalf(submittals), based upon my certification as to accmacy. Assuming completeness of the submittals and approval of this Application, a Building Permit will be issued granting pemrission to me, as Owner, to construct the strnctu:re{s) and facilities detailed on the submittals reviewed by the Building Department. In consideration of the issuance of the Bnilding P~t, I agree that I and my agents wiD comply with provisions of any federal,. state or local law regulating the work and the Garfield County Building Code, ISDS regulations and applicable land use reguJations (County Regulation(s)). I acknowledge that the Building Pennit may be suspended or revoked, upon notice from the County, if the location, construction or use of !he stnu:ture(s) and fuci1ity(ies), described above, are not in complimice with County Regnlation(s)or any other applicable law. I hereby grant pcmrission to 1he Building Department to enter 1he property, described above. to inspect the worlt. I further acknowledge that the issuance of the Building Pennit does not prevent the Bnildi:ng Official fiom: (I) requiring the conection of errors in the submittals. if any, discovered after issuance; or (2) stopping construction or use of the stmcture(s) or facllity(ies) if such is in violation of County Rcgulation(s) or any other nppJicable law. Review of this Application, including submittals,. and inspections of the work by the Building Department do not OOllstitute an acceptance of responst'bility or liability by the County of errors, omissions or discrepancies. As the Owner, I acknowledge that responsibility for compliance with federal, state and local laws and County Regulations rest with me and my authorized agents, including without limitation my architect designer, engineer and/ or builder. I HEREBY ACKNOWLEOOE TIIAT J HAVE READ AND UNDERSTAND THE NOTICE & CERTIFICATION ABOVE: trlfu.J ~ ~C" <t l-t..:J. ·""""' /·U-01- 0 NERS SIGNATURE ""' DATE STAFF USE ONLY Special Conditions: Adjusted Valuation: Plan Chec.;b r "' G Pennit FeeS .L 2 1\ ~ Manu home Fee: Mise Fees: 1--\ \ 22 .. ::, ~ t/ et ISDSFee: TomiFees: Fees Paid: Balance Due: BP No & Issue Date: ISDS No & Issued Date: <f 9Zt~1 3 ');) .,l-f g 5S 6 3 1 .,~ Setbacks: OCCGroup: ConstType: Zoning: :Yt2 (_ BLDG DEPT: PLNGDEPT: ~\j_L "Z -CS" ...-o b" _.,~}-t.-~<>K IL' DATE DATE v -~ Tbe following items are required by Garfield County for a final Inspection: 1) A final Electrical Inspection from the Colorado State Electrical Inspector. 2) Permanent address assigned by Garfield County Building Department and posted at the structure and where readily visible from access road . . 3) A finished roof; a lockable building; completed exterior siding; exterior doors and windows installed; a complete kitchen with cabinets, sink with hot & cold running water, non-absorbent kitchen floor covering, counter tops and finished walls, ready for stove and refrigerator; all necessary plumbing. 4) All bathrooms must be complete, with washbowl, tub or shower, toilet, hot and cold running water, non-absorbent floors, walls finished, and privacy door. 5) Steps over three (3) risers, outside or inside must be must have handrails. Balconies and decks over30" high must be constructed to all me and IRC requirements including guardrails. 6) Outside grading completed so that water slopes away from the building; 7) Exceptions to the outside steps, decks, grading may be made upon the demonstration of extenuating circumstances., i.e. weather. Under such circumstances A Certificate of Occupancy may be issued conditionally. · 8) A final inspection sign off by the Garfield County Road & Bridge Department for driveway installation, where applicable; as well as any final sign offby the Fire District, and/or State Agencies where applicable. A CERTIFICATE OF OCCUPANCY (C.O.) WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS IIA VE BEEN COMPLETED. A C.O. MAY TAKE UP TO 5 BUSINESS DAYS TO BE PROCESSED AND ISSUED. OWNER CANNOT OCCUPY OR USE DWELLING UNTIL A C.O. IS ISSUED~ OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. I understand and agree to abide by the above conditions for occupancy, use and the issuance of a C.O. for the building identified in the Building Permit. /-22 -,;;8 DATE Bapplicationseptember2007 VALUATION FEE DETERMINATION Applicant Address Date -:B~u;:,m:;:e::;,r==-----,--'--,---'-'Subdivision 6171 CR 320 Lot/Block .:2c;/5:!-:/0:-20,::;0;8:..::.=:::....---~-----Contractor Finished (Livable Area): Main Upper Lower Other Total Basement: Unfinished Square Feet Valuation Conversion of Unfinished to Finished Total Valuation Garage: Valuation Crawl Space Valuation Decks/ Patios Valuation Covered Open Type of Construction: Occupancy: Valuation Total Valuation 552 sf sf sf sf X $74.68 552 sf Commercial sf X $41.00 sf X $33.68 sf X $18.00 sf X $9.00 sf X $24.00 sf X $12.00 sf X sf X sf X sf X sf X sf X Beaver Creek Minor lOA Owner 41,223.36 0.00 0.00 0.00 0.00 0.00 41,223.36 ' GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS For SINGLE FAMILY DWELLING CONSTRUCTION Including NEW CONSTRUCTION ADDITIONS ALTERATIONS And MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. When reviewing a plan and it's discovered that required information has not been provided by the applicant, this will result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor shall be required to provide this information before the plan review can proceed. Other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. Any project with more than ten (10) occupants requires the plans to be sealed by a Colorado Registered Design Professional. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following checklist prior to and during design. Applicants are required to indicate appropriately and to submit the completed checklist at time of application for a permit. Plans to be included for a Building Permit, must be on drafting paper at least 18"x24" and drawn to scale. Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks, balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line and original grade. A section showing in detail, from the bottom of the footing to the top of the roof, including re-bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house-rap, (which is required), siding or any approved building material. Engineered foundations may be required. A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. wind speed, wind exposure B or C, and a 36 inch frost depth. All sheets to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be incompliance with the 2003 IRC. 1. Is a site plan included that identifies the location of the proposed structure or addition and distances to the property lines from each corner of the proposed structure( s) prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Properties with slopes of 30% or greater must be shown on the site plan. (NOTE Section: 106.2) Any site plan for the placement of any portion of a structure within 50 ft. of a property line and not within a previously surveyed building envelope on a subdivision final plat shall be prepared by a licensed surveyor and have the surveyor's signature and professional stamp on the drawing. Any structure to be built within a building envelope of a lot shown on a recorded subdivision plat shall include a copy of the building envelope as it is shown on the final plat with the proposed structure located within the envelope. Yes / 2. Does the site plan also include any other buildings on the property, setback easements and utility easements? Please refer to Section 5.05.03 in the Garfield County Zoning Resolution if the property you are applying for a building permit on is located on a corner lot. Special setbacks do apply. / Y es _ ___,v"'---- 3. Does the site plan include when applicable the location of the l.S.D.S. (Individual Sewage Disposal System) and the distances to the property lines, wells (on subject property and adjacent properties), streams or water courses? Yes f'l 1 t"' 4. Does the site plan indicate the location and direction of the County or private road accessing the property? Yes ./ 5. Are you aware that prior to submittal of a building permit application you are required to show proof of a legal and adequate access to the site? This may include (but is not limited to) proof of your right to use a private easement/right of way; A County Road and Bridge permit; a Colorado Dept. of Highway Permit, including a Notice to Proceed; a permit from the federal government or any combination. You can contact the Road & Bridge Department at 625-8601. See phone book for othe.r agencie~ Yes.~_-"'/'---- 6. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordan7with the IRC or per stamped engineered design? Yes __ _::v __ _ 7. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and earth? Yes No / 8. Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces and soffits? Yes _____ _ No _ __.,/::___· _ 9. Do the plans include design loads as required by Garfield County for roof snow loads, (a minimum of · 40 pounds per square foot up to & including 7,000 feet above sea level), floor loads and wind loads? Yes __ _L/ __ _ I 0. Does the plan include a building section drawing indicating foundation, wall, floor, and roof construction? Yes / II. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or jyists or trusses? Yes __ --'./"---- 12. Does the building section drawing or other detail include the method of positive connection of all columns and b~ms? Yes __ ~L£_ __ _ 13. Does the elevation plan indicate the height of the building or proposed addition from the undisturbed grade to the midpoint between the ridge and eave of a gable or shed roof or the top of a flat roof? (Building height measurement usually not to exceed 25 feet) Yes / 14. Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase II certifications or phase II EPA certification? Yes No -./ 15. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the IRC? Yes ______ No __ _.,__ __ _ 16. Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rOOJI'lS and/or basements comply with the requirements of the IRC? Yes __ -=-/ __ _ 17. Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable rooms? Yes ./ 18. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety glazing for these areas? / Yes No ___ ~v' ___ _ 19. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? Yes. _____ _ 20. Do you understand that if you are building on a parcel of land created by the exemption process or the subdivision process, are building plans in compliance with all plat notes and/or covenants? Yes / 21. Do you understand that if you belong to a Homeowners Association (HOA), it is your responsibility to obtain written permission from the association, if required by that association, prior to submitting an application for a building permit? The building permit application will be accepted without it, but you run the risk of the HOA bringing action to enforce the covenants, which can result in revocation of permit issued. Additionally, your Plan Review fee is not refundable if the plans have been reviewed by the Building Department prior to any action by the HOA that requires either revocation or substantial modification of the plans. Yes ./ 22. Will this be the only residential structure on the parcel? Yes / No Ifno-Explain: ______ _ 23. Have two (2) complete sets of construction drawings been submitted with the application? Yes ./ 24. Do you understand that the minimum dimension a home can be on a lot is 20ft. wide and 20ft. long? Yes / 25. Have you designed or had this plan designed while considering building and other construction code requirements? Yes ./ 26. Do your plans comply with all zoning rules and regulations in the County related to your properties zone district? Yes V' 27. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by the GarfieJsi County Building Department? Yes. __ ::_/ __ _ 28. Do you understand that approval for design and/or construction changes are required prior to the application of these changes? Yes / 29. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application submittal and that you will be required to pay the "Permit Fee" as well as any "Road Impact" or "Septic System" fees required, at the time you pick up your building permit? Yes ./ 30. Are you aware that you must call in for an inspection by 3:30 the business day before the requested inspection in order to receive it the following business day? Inspections will be made from 7:30a.m. to 3:30p.m. Monday through Friday. Inspections are to be called in to 384-5003. Yes / No ------ 31. Are you aware that requesting inspections on work that is not ready or not accessible will result in a $50.00 re-inspection fee? Yes / 32. Are you aware that you are required to call for all inspections required under the IRC including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of the building? / Y es __ _::....v" __ _ 33. Are you aware that the Permit Application must be signed by the Owner or a written authority being given for an Agent and that the party responsible for the project must comply with the IRC? Yes / 34. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups, unless you as the homeowner are performing the work? The license number of the person performing the work will be required at time of applicable inspection. Yes / 35. Are you aware, that on the front of the Building Permit Application you will need to fill in the Parcel/Schedule Number for the lot you are applying for this permit on prior to submittal of a building permit application? Your attention in this is appreciated. Yes / 36. Do you k:uow that the local fire district may require you to submit plans for their review of fire safety issues? Yes ___ /,__ ___ (please check with the building department about this requirement) 37. Do you understand that if you are planning on doing any excavating or grading to the property prior to issuance of a building permit that you will be required to obtain a grading permit? Yes / 38. Are you aware that if you will be connecting to a public water and/or sewer system, that the tap fees have to be paid and the connections inspected by the service provider prior to the issuance of a Certificate of Occupancy? Yes i./"" I hereby acknowledge that I have read, understand and answered these questions to the best of my ability. Signature of Owner /J7 77o-98r-2891 2/tJ/), Phone: CZ/o ·~ 230 ·· /OS 7 (days); Project Address: ((217/ Date 970 · 201 -~(JJ-(evenings) Notes: If any required information is missing delays in issuing the permit are to be expected. Work may not proceed without the issuance of a permit. If it is determined by the Building Official that additional information is necessary to review the application and plans to determine minimum compliance with the adopted codes, the application may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review, delay in issuance of the permit or delay in proceeding with construction. BpminreqDec2007 PLAN REVIEW CHECKLIST Applicant f3 LJl.AN , Date 2 -:r=-o.P' ....... Building _Jngineered Foundation V Driveway Permit t?-<.1e;,k £surveyed Site,Plan V'1<11t-'5'"1 *-Septic Permit and Setbacks ~Grade/Topography 30% 0ttach Residential Plan Review List ~Minimum Application Questionnaire J4L Subdivision Plat Notes --,t4:LFire Department Review Jvaluation Determination/Fees ~ed Line Plans/Stamps/Sticker jlju_Attach Conditions LApplication Signed V Plan Reviewer To Sign Application -V Parcel/Schedule No. ~ 40# Snowload Letter-Manf. Hms. GENERAL NOTES: Planning/Zoning ~operty Line Setbacks 1 __....-3Oft Stream Setbacks t.....---'Flood Plain -- \../Building Height b_./Zoning Sign-off Yk,/ Road Impact Fees J 0 ~HOA/DRC Approval V Grade/Topography 40% dPlanning Issues ~Subdivision Plat Notes N 10838 o. ----------~~~----Assessor's Parcel No. 2175-261-01-008 Date 2/12/2008 BUILDING PERMIT CARD Job Address ----~6~1~71~cr~3~2~0~,~R~if~le~(B~e~a~v~e~r~C~re~e~k~M~in~o~r~S~u~b~d~,l~o~t~1~0~A~) _________________________ _ Owner Burner, Mark Address 6171 cr 320, Rifle Phone # 230-1057 Contractor;_· ___ O_w...;_n_e_r _____ ~-----Address __ s_am __ e_a_s_o_w_n_e_r ____ Phone# 970-201-6605 Setbacks: Front _____ Rear _____ RH, _____ LH _____ Zoning _______ _ Kitchen addition INSPECTIONS Soils Test------::---:------- Footing iL -17'-t?B ~ Foundation a-· /.J? Oft~ Grout_~----~-------­ Underground Plumbin9..-------:---=--=-- Rough Plumbing 3-;;, ~:-f)& t9-rvL- Framing · 2 " ZS-~ ll:iii Insulation 3-.:J.?-(j~~ Roofing ---;r--::-----c...--?,..,--------- Drywall -~¥,_-7'2."-:-;J:<Dc::;;.5,._./?r&~-=-=----­ Gas Piping -""'.3'---"':8""'£"'"---''""'D""'-'-'8-'-)f)nLJ.L.L.=---- Weatherproofing _____________ _ Mechanical __________________ _ Electrical Rough (State)------------ Electrical Final (State) _________ -::?>--:n Finai4=-/."J:--;&/Checklist Completed? ~Z/ Certificate Occupancy # ------~--Date _________________ _ Septic System# __________________ __ Date --------------Final _____________________ _ Other _______________ ~----- NOTES C,O, p£71t;c:-r6Je~ j;t}SUCU_!) (continue on back) '·.;."•' G PERMIT COUNTY, COLORADO __ ''""~·'•···~ ••••••••• ;::c ••••..•• L.uuou Area .... , .... .' ..................... Permit No .. \0 ... . AGREEMENT ·:.i.sonsideration ofthe issuance ofthis permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning,:·location, erection and construction of the above described structure, the permit may th~!i'·!be revoked by notice from the County Building Insp.ector and IMMEDIATELY BECOME NULL AND VOID. Use ~It rtrf 'fl ClCl tl Vtiel\0 Address or Legal Description.-"6"')1_,_1..,., .Lft_._?)...,.,_:p),.R),_· \(...,\.:.:~~l f'"'J---~~----'-------- Owner J;)m'flt(, J/YlO.'R.'L Contractor \SWIJi~f" Setbacks Front Side Side Rear -Tbis·Card·Must Be Posted So It is Plainly Visible From The Street Until Final InspectiOn. · Fo:·· Jn•·qH'rt\M~f1''l-::·.t~ali~ APP·Ro\~ D .. '""• n ' oate#\~11~ . )}~~u;~{~\'~' ~ .... I A 1\C:E'i» OUTS~DE-COVER WITH CLEAR PLASTIC '::~~/ '· . ~OUNTY OF GARFIELD m BUILDING DEPARTMENT CORRECTION NOTICE 108 8th St., Suite 401 Glenwood Springs, Colorado Phone (970) 945-8212 Job located at --tJ(d~1-=-/-={!}!__.:-:::.__· ~_'d-O ____ _ Permit No. -~.f-"/O.L!83~[}~,_..,"-· _________ _ I have this day inspected this structure and these premises and found the following corrections needed: I 6t;A .A;M_ - v_w~~~~~~~~~~~ ~_L~~~~~~~~~~~~-­ £~~~~~~~~~~~~-- D Call for Re-lnspection 0 $50.00 Re-lnspection Fee must be paid prior to Re-lnspection You are hereby notified that the above correction must be inspected before covering. When correction(s) have been made, cali for inspection at 970-384-5003. Date ::3-"' j;J_ 20Q5 ------'=--~~ fl "--?1=-=-J ,-_,--=-J) Building Inspector --+~.....,.,""""'~""--~~"---=-=l'C-=~~-·-----==-----­ Phone (970) 945-8212 Parcel Detail Page 1 of4 Garfield County Assessor/Treasurer Parcel Detail Information AssessorLirea§urer Property$e.llfch I Assessor SJJhset Query I Assel>§Qr Sales Search Clexk & Recorder Reception Search Bl!sic Building_Cbarl!c~J:istics I ThxJ!lfJlrmation Parcel Detail I Value Detail I Sales Detail I ResLd~ntial/Commerciallmprovement Detail L®d Detail I Photogmphs I Tax Area II Account Number II Parcel Number II 2007 Mill Levy I I o24 II R247118 II 2175261owo8 II 45.837 I Owner Name and Mailing Address !BURNER, MARK L & JULIE E I J6171 COUNTYROAD320 I JRIFLE, CO 81650 I Legal Description JSECT,TWN,RNG:26-6-94 DESC: NE 114 I JsuB:BEAVERCKMlNORSUB REPL7&10 I JLOT:10A PRE:R024298 AND/THRU:& I !TO:R024301 BK:l185 PG:261 I JRECPT:562882 BK: 1185 PG:259-260 I IRECPT:562881 BK:1035 PG:0770 I IBK:0851 PG:0749 I Location I Physical Address: JJ6171 320 COUNTY RD RIFLE I s bd' . . IIBEAVER CK MINOR SUB REP u IVISion: L7&10 I Land Acres: JJ6.85 I Land Sq Ft: Jlo Section II Towns hi~ II Range I II II http:/ /www.garcoact.com/assessor/parcel.asp?ParcelNumber=217 526101 008 1123/2008 Parcel Detail Page2 of4 II 26 II 6 II 94 ,, 2007 Property Tax Valuation Information II Actual Value II Assessed Value I I Land: 130,00011 10,3501 I Improvements: 327,58011 26,0801 I Total: I 457,58oll 36,4301 Sale Date: lls/1/2000 Sale Price: 1!340,000 Basic Building Characteristics Number of Residential 1 Buildings: Number of Commllnd lo I Buildings: I Residential Building Occurrence 1 Characteristics I I TOTAL HEATED AREA: 113,144 I I ABSTRACT CODE·IISINGLE F AM.RES-• IMPROVEMTS I I ARCHITECTURAL STYLE: 111-STRY/BSM I I EXTERIOR WALL: IIMASONITE I I ROOF covER: llcoMP SHNGL I I ROOF STRUCTURE: IJGABLE I I INTERIOR WALL: IIDRYWALL I I FLOOR: IIHARD TILE I I FLOOR: llcARPET I I HEATING FUEL: IJGAS I I HEATING TYPE: IJFORCED AIR I I STORIES: IJSTORIES 1.0 I I BATHS: I 3.5 I ROOMS: 18 I UNITS: 11 I BEDROOMS: l14 I YEAR BUILT: IJ1997 I http:/ /www.garcoact.com/assessor/parcel.asp?ParcelNumber=217 5261 01008 1123/2008 Parcel Detail Tax Information I Tax Year Transaction Type II Amount I 2007 Tax Amount II $1,669.841 2006 Tax Payment: Second Half II ($650.34)1 2006 Tax Payment: First Half II ($650.34)1 2006 Tax Amount II $1,300.681 I 2005 II Tax Payment: Second Half II ($653.42)1 I 2005 II Tax Payment: First Half II ($653.42)1 2005 II Tax Amount II $1,306.841 2004 II Tax Payment: Second Half II ($695.17)1 2004 II Tax Payment: First Half ($695.17)1 2004 II Tax Amount $1,390.341 2003 II Tax Payment: Second Half ($772.87)1 2003 II Tax Payment: First Half ($772.87)1 2003 II Tax Amount $1,545.741 2002 II Tax Payment: Second Half ($825.22)1 2002 II Tax Payment: First Half ($825.22)1 2002 II Tax Amount $1,650.441 2001 II Tax Payment: Second Half ($843.4421 2001 II Tax Payment: First Half ($843.44)1 2001 II Tax Amount $1,686.881 2000 II Tax Payment: Second Half ($802.69)1 2000 II Tax Payment: First Half ($802.69)1 I 2000 II Tax Amount $1,605.381 I 1999 II Tax Payment: Whole ($858.32)1 I 1999 II Tax Amount $858.321 IQJ1 of Page Al!sessor Database Sem:chD_mimls I TreasJJrer Database Search Options .CLe.rk & Recorder Databas_e ... Sem:ch 0];1tions Garfield.CountyHomePage Page 3 of4 The Garfield County Assessor and Treasurer's Offices make every effort to collect and maintain accurate data. However, Good Turns Software and the Garfield County Assessor and Treasurer's Offices are unable to warrant any of the information herein contained. http://www.garcoact.com/assessor/parcel.asp?Parce1Number=217 526101008 1123/2008