Loading...
HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT BLRE-5-15-3639 Aspen Signature Homes, LLC Lot 293 Ironbridge PUD 1387 River Bend Way GWS, Colorado 1) SEE PLAN ATTACHMENTS FOR BUILDING REQUIREMENTS. 2) ALL WORK SHALL COMPLY WITH THE 2009 INTERNATIONAL RESIDENTIAL CODE (IRC) AND THE MANUFACTURERS INSTALLATION SPECIFICATIONS. 3) STEPS TO GRADE AND REQUIRED LANDING AT COVERED PATIO SHALL NOT ENCROACH PAST THE PROPERTY LINE, RELOCATE AS NECESSARY. 4) ONE (1) HOUR FIRE-RESISTANT CONSTRUCTION REQUIRED TO UNDERSIDE OF WATERPROOF DECK PROJECTION PER 2009 IRC, TABLE R 302.1. 5) MINIMUM 8" X 8" WOOD POST REQUIRED AT WATERPROOF DECK, AS SPECIFIED PER 2009 IBC, 202.4.1, HEAVY TIMBER, OR PROVIDE ONE (1) HOUR FIRE-RESISTANT CONSTRUCTION. (CONSIDERED THE SAME AS A WALL SUPPORTING FLOOR LOAD) 6) ROOF AND SURFACE DRAINAGE MUST COMPLY WITH 2009 IRC, SECTION 801.3 AND THE RECOMMENDATIONS OF THE GEOTECHNICAL ENGINEER. REFER TO ATTACHED REPORT. 7) OPEN -HOLE SOILS REPORT REQUIRED AT FOOTING INSPECTION, 1000 PSF. 8) ENGINEERED FLOOR TRUSS SHOP DRAWINGS REQUIRED AT FRAME INSPECTION. 9) ENGINEERED TRUSS SHOP DRAWINGS ARE REQUIRED AT FRAME INSPECTION, 40 PSF. 10) ELECTRICAL ROUGH -IN APPROVAL IS REQUIRED FOR FRAMING INSPECTION. 11) ELECTRICAL FINAL APPROVAL IS REQUIRED FOR CO/FINAL INSPECTION.