Loading...
HomeMy WebLinkAboutApplication-PermitI Garfield County Building & Planning Department 108 8th Street, Suite #401 Glenwood Springs, Co. 81601 Office:970-945-8212 Fax: 970·384-3470 Inspection Line: 970-384-5003 Building Permit No. 10876 Parcel No: ----~· ~~·~---~~.2179-341-05-005 Locality: __ (:;hipperfielcl Estates, ~~o_t 0 __ Job Address: _____ 4_558 CR 331 ,~Si-'-lt __ Use of Building: --··~---___ garage (metal bldg) Owner: ___ __:.c.Ht?.IT~meister, Jer:J.ry __ Contractor: Owner ---· Fees: Plan Check: 441.19 Septic: Bldg Permit: 678.75 Other Fees: Total Fees: $ 1,119.91_~ Clerk: ~\D~ Date: ··--- 3/26/2008 I GARFIELD COUNTY BUILDING PERMIT APPLICATION 10881l1Strea, &J!te401, GlawoodSprings, Co 81601 Phone: 970-945-82121 Fa(: 970-384-3470/lnspe::\ion Line: 970-384-5003 www.gaiield-oountv.com CERTIFICATION I tJ:reb; CErtify thaI halen:a:t ttisA~icaioo n:i tha thainfam::tioo arleined Wweistn.earl oorre:i. I ~ thet the Bl..ildng D~ a::a:ptstreApPicetioo, aav with theplalS axiSfX;'dfialionsEJldcther d:ia&Jbrritta::l tJf rreor oo my betlaf (subnittals), based~ 11¥ cetificaionooto~. A6SJ'Iill} oorrpiEtE!"le$of the9Jbnittasm:l ~al of thisAwlicaion, a Building R;mit will beiss.Jerl grring p::rrris9oo to rre, a:: C>woa", toCJJrl!irU;:t trest:ru:ttrE(s} jJ"d fa::ilitiesc.JEtaled on thes.trrittasrwie.vocl bJ the BLilding [)epatrEot. In CUJ$idEJ<;tjon d ttei~of the BuildlrQ Panit, I Mf fec:i::ra, staeoc loc:a IBN regula:Jng theWCX'k a'dtteGafiEid Colnty Buildifl'! CclOO, IOOSregul~imsm:l be~ or reJoke::l, upoo nctloefrantheCoonty, if thelcx::aion, a;ntn.dionoru:;:eof the BuildiNJ Famt does not pretB"ll: the if SlY, i the work. by the Building DEpaitrralt do rot oonstltutem ~of re::porlSibility or lir::t41ity by theCoonty of arors, onisS:oos I for CO!llJiiarewlthfe:iE.r€1, staem 1oc:a lavsm::l County REQJa:Joosreltwith rren:l mJ B.Jthaizad ~ irdudingwittn.rt ruld<r. I HAVE READ AND UNDERSf AND THE NOTICE & CERTIFICATION ABOVE STAFF USE ONLY Special Conditions: Adjusted Valuation: Plan Cbeck Fee: Permitbl ~ '1 S" Manu home Fee: Mise Fees: 'S"f 1 Ll31 f-') '-14\ 1"1 f ( ISDSFee:f Total Fees: Fees Paid: Balance Due: BP No & Issue Date: ISDS No & Issued Date: \ \ \"' '\'\ 11'{/. 19 ~18'1} !\081£ .......---- Setbacks: OCCGroup: ConstType: Zoning: ~(2-.L ' BLDG DEPT: PLNGDEPT: .u\l "'3 . ;)_L,. og' bi'--10---::?"" "J..i, -or' p DATE OVUJ DATE The following items are required by Garfield County for a final Inspection: 1) A final Eledricallm:pedion fromtheColora:lo StateEiedricallnspector. 2) Permanent a:ldressassigned by Gcrlield County Building Department lil1d posted at the structure and where rea:li ly visible from c:n:ess roa:l. 3) A finished roof; a lockt:Pie building; completed exterior siding; exterior doors and windows installed; a complete kitchen with cal:>inets, sink with hot & cold running water, non-amrbent kitchen floor covering, counter tops and finished walls, rea:ly for stove and refrigerator; all n~ plumbing. 4) All bathrooms must be complete, with washbowl, tub or shower, toilet, hot and cold running water, non-amrbent floors, wallsfinished,lil1d privccy door. 5) Steps over three (3) risers, oUtside or inside must be must have handrails. Balconies and de::k:s over 30Dhigh must be constructed to all IBC lil1d IRC requirements including guardrails. 6) Outside grading completed s:> that w!iter slopesaNay from the building; 7) Exceptions to the outside steps, de::k:s, gra:ling may be made upon the demonstration of extenuating circumstances., i.e. wa:ther. Under such circumstances A Certificaleof Ocoupancy may beissua:l conditionally. 8) A final inspection sign off by theGcrlield County Roa:l & Bridge Department for drive.vay installation, where applicable; as well as any final sign off by the Fire District, and/or Stale Agencies where C1Jpl ical:>l e. A CERTIFICATE OF OCCUPANCY (C.O.) WILL NOT BE ISSUED UNTIL~ THE ABOVE ITEMS HAVE BEEN COMPLETED. A C.O. MAY TAKE UP TO 5 BUSINESS DAYS TO BE PROCESSED AND ISSUED. OWNER CANNOT OCCUPY OR USE DWELLING UNTIL A C.O. IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. I understand lil1d agree to f:bi de by the f:bove conditions for occupancy. use and the i$Uance of a C.O. for the building identified in the Building Permit DATE VALUATION FEE DETERMINATION Applicant Address Date .:;Ho;o~ffm~e:;:is::;te~r-;---:--------,.,..~-Subdivision 4558 CR 331 Lot/Block -:3:.:;:/2::'6":/2~0C:OC:8=--.,.,-----'----Contractor Finished (Livable Area): Main Upper Lower Other Total Basement: Unfinished Square Feet Valuation Conversion of Unfinished to Finished Total Valuation Garage: Valuation Crawl Space Valuation Decks/ Patios Valuation Covered Open Type of Construction: Occupancy: Residential steel garage Valuation Total Valnation sf sf sf sf X $74.68 0 sf Commercial sf X $41.00 sf X $33.68 sf X $18.00 sf X $9.00 sf X $24.00 sf X $12.00 1815 sf X $29.99 sf X sf X sf X sf X sf X Chipperfield Estates Parcel 5 owner 0.00 0.00 0.00 0.00 0.00 54,431.85 54,431.85 Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks, balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line and original grade. A section showing in detail, from the bottom of the footing to the top of the roof, including re-bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house-rap, (which is required), siding ot any approved building material. Engineered foundations may be requir~d. A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. wind speed, wind exposure B or C, and a 36 inch frost depth. All sheets to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be incompliance with the 2003 IRC. 1. Is a site plan included that identifies the location of the proposed structure or addition and distances to the property lines from each comer of the proposed structure(s) prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Properties with slopes of 30% or greater must be shown on the site plan. (NOTE Section: 106.2) Any site plan for the placement of any portion of a structure within 50 ft. of a property line ;md not within a previously surveyed building env\)lope on a subdivision final plat shall be prepared by a licensed surveyor and have the surveyor's signature and professional stanip on the drawing. Any structure to be built within a building envelope of a lot shown on a recorded subdivision plat shall include a copy of the building envelope as it is shown on the final plat with the proposed structure located within the envelope. Yes¥ 2. Does the site plan also include any other buildings on the property, setback easements and utility easements? Please refer to Section 5.05.03 in the Garfield County Zoning Resolution if the property you are applying for a building permit on is located on a comer Jot. Special setbacks do apply. Yes~ 3. Does the site plan include when applicable the location of the l.S.D.S. (Individual Sewage Disposal System) and the distances to the property Jines, wells (on subject property and adjacent properties), streams or water courses? Yes f-P'? 4. Does the site plan indicate the location and direction of the County or private road accessing the property? Yes !{~1;, 2 5. Are you aware that prior to submittal of a buildjng permit application you are required to show proof of a legal and adequate access to the site? This may include (but is not limited to) proof of your right to use a private easement/right of way; A County Road and Bridge permit; a Colorado Dept. of Highway Permit, including a Notice to Proceed; a permit from the federal govermnent or any combination. You can contact the Road & Bridge Department at 625-8601. See phone book for other agenci~s Yes 'f#'7 6. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the IRC or per stamped engineered design? Yes 'f..f,$ . 7. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between woog and earth? Yes No_N'-' 7 'f<(ll:.,_ __ 8. Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces and soffits? Yes No~~~~--~ 9. Do the plans include design loads as required by Garfield County for roof snow loads, (a minimum of 40 pounds per sq\lare foot up to & including 7,000 feet above sea level), floor loads and wind loads? Yes t{ol~ 10. Does the plan include a building section drawing indicating fo\lfidation, wall, floor, and roof construction? Yes l(<?/ez 11. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or joists or trusses? Yes if-b'? 12. Does the building section drawing or other detail include the method of positive connection of all columns and beams? Yes l{+'z 13. Does the elevation plan indicate the height of the building or proposed addition from the undisturbed grade to the midpoint between the ridge \lid eave of a gable or shed roof or the top of a flat roof? (Building !)eight measurement usually not to exceed 25 feet) Yes 'jth 14. Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase II certifications or phase II EPA certification? Yes No J.)t; --'---"----- 3 15. Does the plan irnclude a masonry fireplace including a fireplace section indicating design to comply with the IRC? Yes No__,Po=--'-.-- 16. Does the plan include a window schedule or other verification that egress/rescue wipdows from sleeping ~ms and/or basements comply with the requirements of the IRC? Yes 'i 17. Does the plan include a window schedule or other verification that windows provide natural light and ventilatio£ for all habitable rooms? Yes IJ f:l. I 18. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specifY safety glazing for these areas? Yes No_.;_AJ'-f.~~.;fl~-- 19. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? /i Yes IJ A I 20. Do you understand that if you are building on a parcel ofland created by the exemption process or the subdivision process, are building plans in compliance with all plat notes and/or covenants? Yes "{M 21. Do you understand that if you belong to a Homeowners Association (HOA), it is your responsibility to obtain written permission from the association, if required by that association, prior to submitting an application for a building permit? The building permit application will be accepted without it, but you run the risk of the HOA bringing action to enforce the covenants, which can result in revocation of permit issued. Additionally, your Plan Review fee is not refundable if the plans have been reviewed by the Building Department prior to any action by the HOA that requires either revocation OJ substantial modification of the plans. Yes -.l/7 ly resid~structure on the parcel? . y es;_--1.1~~=:::-7-No If no-Explain: w~-e. 23. Have two (2) complete sets of construction drawings been submitted with the application? Yes ?j;-ld 24. Do you understand that the minimum dimension a home can be on a lot is 20ft. wide and 20ft. long? Yes tf -t!i; 4 25. Have you designed dr had this plan designed while considering building and other construction code requirements? Yes '/05 26. Do your plans comply with all zoning rules and regulations in the County related to your properties zone district? Yes l('t6 27, Does the plan accurately indicate what you intend to construct and what will receive a final inspection by the Garfield County Building Department? Yes r~ 28. Do you understand that approval for design and/or construction changes are required prior to the application of these changes? Yes y..vz 29. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application submittal and that you will be required to pay the "Permit Fee" as well as any "Road~~. act" or "Septic System" fees required, at the time you pick \lP your building permit? Yes ~ 30. Are you aware that you must call iu for an .inspecti()n by 3:30 the business day before the requested inspection in order to r~eive it the following business day? Inspections will be made from 7:30a.m. to 3:30p.m. Monday through Friday. Inspections are to be called in to 384-5003. Yes t(<e¢ No _____ _ 31. Are you aware that requesting inspections on work that is not ready or not accessible will result in a $50.00 re-inspection fee? Yes {11/4 I 32. Are you aware that you are required to call for all inspections required under the IRC including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of the building? 11 L Yes t£..c// 33. Are you aware that the Permit Application must be signed by the Owner or a written authority being given for an.Agent and that the party responsible for the project must comply with the IRC? Yes ~,j)z 5 34. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups, unless you as the homeowner are performing the work? The license number of the person performing the work will be required at time of applicable inspection. Yes ~../!, '7 35. Are you aware, that on the front of the Building Permit Application you will need to fill in the Parcel/Schedule Number for the lot you are applying for this permit on prior to submittal of a building pernj.it application? Your attention in this is appreciated. Yes l('tb 36. Do you know that the local fire district may require you to submit plans for their review of fire ~afety issues? ' Yes (please check with the building department about this requirement) 37. Do you understand that if you are planning on doing any excavating or grading to the property prior to iss~VfAof a building permit that you will be required to obtain a grading permit? Yes -~'J--=._L __ 38. Are you aware that if you will be cormecting to a public water and/or sewer system, that the tap fees have to be paid and the connections inspected by the service provider prior to the issuance of a Certificate of Occupancy? Yes tf-?7 I hereby ackn!)wledge that I have read, understand and answered these questions to the best of my ability. ~-Wr-cCJ .). -J--;H <J Si~e ~0~ Date Phone:9'7o~t,/~ -15'~</ (days); Project Name: ~IYL&f&HY 9] 0 -7J 7 &--;ta 'i)O (evenings) Project Address:__,~--"'-'£-'. "'----'=(..,~fZ"--"-~~2'-'1'-----"7_1_/_,_f__,/'--(}()_· __.:_' --'<-&'-'-/(,:::...b-_2-__ ~ 6 Notes: If any required infonnation is missing delays in issuing the permit are to be expected. Work may not proceed without the issuance of a permit. If it is determined by the Building Official that additional information is necessary to review the application and plans to determine minimum compliance with the adopted codes, the application may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review, delay in issuance of the permit or delay in proceeding with construction. BpminreqDec2007 7 PLAN REVIEW CHECKLIST Applicant l fo.ft!M o • ,-4, Date 3 -).,(. -0 lr Building UEngineered Foundation ~Driveway Permit fE:Jtt ')~ ~urveyed Site Plan /Septic Permit and Setbacks --LL.. Grade/Topography 30% /Attach Residential Plan Review List LMinimum Application Questionnaire ~ubdivision Plat Notes .Fire Department Review ~Valuation Determination/Fees __0ed Line Plans/Stamps/Sticker ~Attach Conditions £Application Signed ~Plan Reviewer To Sign Application Vr:cel/Schedule No. ;4!,L 40# Snow load Letter-Manf. Hms. _J Soils Report GENERAL NOTES: Planning/Zoning ~roperty Line Setbacks ~ft Stream Setbacks ,/Flood Plain -t,.LBuilding Height V Zoning Sign-off -~.,..L-Road hnpact Fees _)ju_HONDRC Approval --t,.L_Grade/Topography 40% ~Planning Issues L/ Subdivision Plat Notes No. _________ ~1~0~87~6L_ __ _ Assessor's Parcel No. 2179-341-05-005 Date 3/26/2008 BUILDING PERMIT CARD Job Address ___ _.!i4i:il51il5.o.8..l.Cr..~:RL3.J.o3:1..J1t.-, .>::~Swilt.L....l(l.l.C<.IJhtqip.qpaea.rfUJie;;ul.u.d..JOEdlsll.lta:ut.£es;:o,,u.L..~.ou.t.J.IO:!LO __________________________ _ Owner Hoffmeister, Jerry Address 4550 CR 331. Silt Phone # 618-7554 Contractor ___ _,O...,w~n""e..,_r __________ Address --------'s"-'a""-m:..:.;e=----Phone # 876-2080 Setbacks: Front _____ Rear ______ RH _____ LH _____ Zoning ____ _ garage (metal bldg) Soils Test ~ -=h Footing. lfy;S.-dffJDEula VA. FoundatJon __ :::2....;..t.-..J4~:-'-:.::L2--'-'-~~~FJc::..r ___ _ Grout ____________ __ Underground Plumbing ________ _ Rough Plu robing ----=-~~.,.-,--­ Framing G-~~ ~ lnsulationO/CAJi/il 02..4/-tJfi Roofing ____________ _ Drywall ------------- Gas Piping------------ INSPECTIONS NOTES Weatherproofing ___________ _ Mechanical _____________ _ Electrical Rough (State) -;:;;r--::;-.,----,--,.,_--r---Eiectri~IJ.inal (State) Jt.-3/~at( ~ Final/ " JO CO /Checkli~t. ctompleted ?:=::-'-..::.....;'--- Certificate Occupancy # -m"'i 0! Lfo c (" <:;:; 1 "'? ·~=· Date l .,..:;,,;;, 1 1--D · , · Uo Septic System# ___________ _ Date -------------Final ____________ _ Other _______________ __ (continue on back) INSPECTION WILL NOT BE MADE UNLESS THIS CARD IS POSTED ON THE JOB 24 HOURS NOTICE REQUIRED FOR INSPECTIONS BUILDING PERMIT GARFIELD COUNTY, COLORADO Date Issued .• J.f.~~'2~ ..... Zoned Area ...•.••...•.•.•...•...•....•.•. Permit No .•... \.~:J?.::\4. .......... . AGREEMENT In consideration of the issuance of this permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the abpve said regulations ·are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building Inspector and IMMEDIATELY BECOME NULL AND VOID. Use Q_c)~l).tp::_ ( 'M~oL ~\~~ Address or Legal Description !.l_ l\'S ';S,D' ()' ;') '}, \ I =::)1 \..} Owner '&JW'MI:I1ff',~~jl'-l Contractor \JwV\1{"' Setbacks Front Side Side Rear This Card Must Be Posted SoU is Plainly Visible From The Street Until Final Inspection. INSPECTION RECORD Footing If ·!'5'-og ,Qh-1 UJJ-Pi< Driveway Foundation &;"'""",f.~:" '1-v ~->~"f. s~ 1 J <-.) b.,...,~.,... o)t.... 7U-- Underground Plumbing ~ Insulation Df Rough Plum bing ~"-' Drywall ---?i.A.--- Chimney & Vent ~ Electric Final (by State lnspector\;,t-v.~~/1. Gas Piping -n.-,_.... Final J.Z. '3/-oe AJM Electric Rough (By State Inspector) v Septic Final 7U-- Framing (fl-/f"-c/5 ~-Notes: (To include Roof m place an Windows and Doors insta11ed). ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING· WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND. THIS PERMIT IS NOT TRANSFERABLE For Inspections Call 384-5003 I 08 8th Street Glenwood Springs, Colorado APPROVED DO NOT DESTROY THIS CARD Date"':>·ot-(:K By f.l/J@jO!{; IF PLACED OUTSIDE-COVER WITH CLEAR PLASTIC SCOPE OF WORK HOFFMEISTER 4550 CNTY RD 331 SILT, CO • Erect a new Engineered Steel building 33' X 55' next to existing home • Location-ParcelS of Sec NE \4 of Sec 34, T.6,S.,R92, of the 6"' PM • Building Specs 40pd snow load I 00 mph wind • Building will be insulated, it will have 5·3x3 windows, 1·14'w x 12'h Garage door and l-3'x6' steel walk through door with no glass • Building will have 1-110 outlet and 2 overhead lights • Concrete, Electrical and Building Erection will all be completed by homeowner • Digging or Grading approximately 20 yds of dirt for thickened edge or monolithic Slab at location • Building will be used for storage and Garage • This building will be using the existing access to property Home phone 970-876-2080 Cell phone 970-618-7554 Garfield County Road & Bridge Department P.O. Box 2254 Glenwood Springs, CO 81602 Phone: 970-945-6111 Fax: 970-945-0934 King Lloyd, Supervisor Today·s Date: 02-26-1997 Please remit for the following permit(s): Date of Issue 02-26-97 PERMIT(s) 1*: 012-97 0 Name: HOFFMEISTER, JERRY Bond Holder: Address: 1000 GLEN OAK LANE City: GLENWOOD SPRINGS ST: co ZIP: Phone: 945-6866 Utility Cut Parmi ts-#" s: From: To: or· i veway Permits-#"s: From: 012-97 To: 012-97 over Size Perrni ts-#" s: From: To: over Weight Permits-#"s: From: To: Fax/Administrc. TOTAL DUE -> -> 1 5. 00 For Gar ·· Pleas Paid it J:i"s No) __ On Check~~~­ Check tl:~ ~ I 81602 Total Utility .oo Total Driveway 15.00 Total Over Size .00 Total Over Weight .oo .00 P.O. Box 396 Chowchilla, California 93610 Office {559) 665-9200 Fax (559) 665-0879 Toll-Free {800) 574-9484 MET ALBUILDINGFOUNDATIONS.com Foundation Design Calculation Package This Design Calculations Package has been prepared using the latest applicable codes and standards and the latest developments in engineering practices. A design engineer prepared the calculations and a building specialist checked the detailing and drafting. Computer programs, verified by Salsa Steel Corp. have been used where applicable to determine structural requirements. The output of these programs have been incorporated in this package together with explanation text where necessary. Please use this calculations package in conjuction with the drawings provided. This design calculation package may be submitted along with the plans for the plan review/permit process. For any questions regarding this package please do not hesitate to contact our office. Salsa keeps records for reference on design calculations for each building/foundation designed as a part of the Salsa Total Quality System. Project Name: Jerry Hoffmeister Project Address: 4550 CR 331 Silt, CO 86512 End Use Of Building: Garage Building Dimensions: Building Type: Gable Responsible Party: Builder Information: Project Name: Jerry Hoffmeister 33' Width 55' Length 12 ' Height Project Conlrql Number SHEET 11111111111111 ~11111111 illllllllllllllllllll * s s -0 3 1 7 3 * DesignSpecifications Codes and loads Governing Code: Seismic Design Category: Design Stresses Wind Pressure: Closed/Open: Exposure: Soil Profile: Snow Load: (Pg =) Frost Depth: Soil Pressure: Concrete: Reinforcement: Concrete Masonry Units: Misc. Steel: Welds: Fo'l.inoation J/,~~', Slab Thickness: Slab Reinforcement Type: Slab Reinforcement Size: Reinforcement Spacing: Perimeter Footer Type: Concrete Mix Portland Cement: Water: Fine Aggregate: Coarse Aggregate: Maximum Slump: IBC 2003 D 1 00 mph 3 second gust Closed c Sd 40 36" 1 ,000 psi-Vertical 150 psi-Lateral 3,500 psi A-615 Grade 40 #4 bars and smaller Grade 60 #5 bars and larger A-185 Welded Wire Reinforcement F'm = 1,500 psi (Prism Test Record) F'y = 36 ksi E-70 Electrodes 21 kli 4 .. Fiber None 0 " on center each way Load Bearing 12"x12" 5 Sack Mix 0.58 Water/Cement Ratio Well Graded 3/4 .. 4 .. 1. All bearing footings shall extend a minimum of 12" into native soil 2. Allowable soil bearing capacity shall be computed with 20% increase for each additional foot of depth, unless noted otherwise 3. 1/3 increase for short term loadings 4. All footings shall be centered below columns, unless noted otherwise. Project Control Number 11111111111111111111111111111111111111111111111 Project Name: Jerr Hoffmeister * s s -0 3 1 7 3 * SHEET 2 9 B B (1) #4 Hairpin x 20' Typ. 014 See Hairpin Detail A A Project Name: Jerry Hoffmeister Buildinglayout A c 4" concrete Slab A w/1.5# Per Cu. Yd. Mesh Fiber o/4" Crushed Base Or o/2" Sand o/1 0 mil Vapor Barrier Well Compacted) Project Control Number 11111111111111111111~11111111111111111111111111 * s s -0 3 1 7 3 * B B SHEET SlabCalculator ~!i'~~R~~l!!llT'~~~ili:Jme !J\Ii5jl?il!;ti!,iB~int~~~~mliii~1f¥:"' ''7~ Slab Thickness= 4.00 " we= 150 pcf ft= 3,500 psi f,= 1.6 • ,j3500 * (4/3) Sm= 12"(4")A2/2 M 5 = 50LA2/2 * 1 2 = 125.89 psi 32 in 3 = = t= M L = ,j125.89417778436 = 300 in-lbs. 3.66 l.f. Type: Fiber Size: Spacing: Depth Of Reinforcement: s None 0" o.c. 2 " (Mid Depth of Slab) Areinf per foot= 0.442/0 As= M ad = 0= 50L 2 3500 1.44(4/3)(2") = t =0(1.44)(1.33)(2") 70 .". L = y'70(0)(1.44)(1.33)(2") Diameter Area 0.7500 0.4416 = 0.000 in 2 /l.f. = 0.00 l.f. 3.66 l.f. + 0 l.f. = 3.66 linear feet of slab will lift off before it breaks Project Control Number 1111111111111 i mlllllll!lllllllllllllllll Project Name: Jerry Hoffmeister * s s -0 3 1 7 3 * SHEET eFootingOPTIMIZER™ A Column Type Rigid Frame Quantity 4 Frame Reactions Pv= 15.10 K} Pu= 4.50 K Max Loads From Cales Ph= 4.60 K Bracing Reactions Pv= 0.00 K Does Not Govern Pu= 0.00 K Does Not Govern Check Footing Size 3.25 'long X 3.25 'wide X Allowable Soil Bearing= q= [ 1 000 [ 1.2) " 3-1 ]] = Soil Friction= 11= 1440 I (3.25 * 3) = Wt of Footing = 150 (3.25) (3.25) (3) = Wt of Slab= (44) (50) = Soil Friction= [(2) * (3.25) + (2) * (3.25)] * (3-1 ) * 148 = Check Bearing Capacity Actual Soil Bearing= qact 15.10 (3.25) X (3.25) = Check Reinforcement Pminlong= 0.002 PminHor~= 0.002 Longitudinal As= 0.002 * (39) * (36)= Horizontal As= 0.002 * (39) * (36)= Design Criteria Use Footing Yes Use Slab Yes Allowable Increase For Width No Allowable Increase For Depth Yes Use Friction Yes Is Footing Square Yes 3.00 ft. deep 1,440 p.s.f. 148 p.s.f. 4,753 # 2,200 # 3,840 # 10,793 > 1,430 < 4,500 OK 1,440 OK Req. As Total As 2.808 < 3.068 OK 2.808 < 3.068 OK Use 3'-3" long x 3'-3" wide x 3'-0" ft. deep Concrete Footing, With (5) #5 bars longitudinal top and bottom along with (5) #5 horizontal bars top and bottom. . .. No Warnings! Project Control Number 11111111111111 ~111111111111~1111111111111~1111 SHEET 5 Project Name: Jerry Hoffmeister * s s -0 3 1 7 3 * 9 4.60 K Force Each Side Of Pin F = __ 4.::..6:::.:0:...__ 2(0.866) Size Hairpin As = _.,..:2::.:..6::.:6::,-_ 20(4/3) = = Footing A 2.66 k 0.0996 in. 2 \ ". I \ I g' .. gu v Use (1} #4 Rebar x 20' Long Hairpin Project Control Number lll~llllllllllllllllllllllilllllll Project Name: Jerry Hoffmeister SS-03173 SHEET 6 9 Hair Pin Information USE Size QTY ~"'*".,;~~-m-:#4~---~ -~P~­ " ' ' 20 ' Long " ' " ' 1 #N/A Reinforcerr Diameter Area 0.3750 0.5000 0.6250 0.7500 0.1104 0.1963 0.3066 0.4416 #3 #4 #5 #6 Column Type Endwall Column Quantity 8 Frame Reactions P,= eFootingOPTIMIZER™ B Design Criteria Pu= Ph= 7.10 K} 2.10 K 1.40 K Max Loads From Cales Use Footing Yes Use Slab Yes Allowable Increase For Width No Allowable Increase For Depth Yes Use Friction Yes Is Footing Square Yes Bracing Reactions P,= Pu= Check Footing Size 0.00 K 0.00 K 3.00 'long x Does Not Govern Does Not Govern 3.00 'wide Allowable Soil Bearing= Soil Friction= q = [ 1000 [ 1.2) "3-1]] !! = 1440 I (3 * 3) Wt of Footing = 150 (3) (3) (3) Wt of Slab= (38) (50) Soil Friction= [(2) * (3) + (2) * (3)] * (3-1 ) * 160 Check Bearing Capacity Actual Soil Bearing= qact = ---,-(3,.,~-·~-~,.,3,...) -- Check Reinforcement P min Long= 0.002 P min Horlz= 0.002 Longitudinal As= 0.002 * (36) * (36)= Horizontal A.= 0.002 * (36) * (36)= X = = = = = = 3.00 ft. deep 1,440 p.s.f. 160 p.s.f. 4,050 # 1,900 # 3,840 # 9,790 > 789 < Req.A. 2.592 < 2.592 < 2,100 OK 1,440 OK Total As 3.068 OK 3.068 OK Use 3'-0" long x 3'-0" wide x 3'-0" ft. deep Concrete Footing, With (5) #5 bars longitudinal top and bottom along with (5) #5 horizontal bars top and bottom. . .. No Warnings! Project Control Number 111111111111111 illlllllll~llllli 1111111111 SHEET 7 Project Name: Jerry Hoffmeister * s s -0 3 1 7 3 * 9 AnchorBoltSizer Check AllcfiOr BOh Eml;leddment Anchor Bolt Design -Strength Design Method For Anchors Closer Than 2x Their Embeddment Depth Loads Vertical Horizontal Loads are in Kips DL = 1.44 0.38 LL WL = Seismic 4.79 -4.98 2.95 Sot.T PlA. • P EDGI2' O!ST. -R .. t + .750 TOTAL SLOPING AAEA '"' Ar. FLAT SOT. ARrA .. At 1.58 -2.73 1.04 CONE SLANT l-ENGTH -1.+H(E) j:o!IR f!O! I <iQI!ABf P.t,WRff• COl*: AREA"''il(1 ..... 14)(E)(R+.71ID) -l-442(£)'+6.6$3{0)(E) SlANT AREA STirN 1/<t CONES-<4(,1.-1-1-+}(E)(S} Anchor Bolt Group Capacities Anchor Bolt Diameter = Anchor Bolt Area Anchor Bolt Gauge = Anchor Bolt Spacing Edge Distance Sidewall = Edge Distance Endwall Length of Embedment Washer Diameter or Hook Length Number of Bolts Special Inspection Required Embedded in Tens ion Zone Concrete Weight Factor Strength Reduction Factor Uve Load Factor Concrete Strength BoltTensile Strength (Uit) Edge Distance Shear Cone Area Flat Bottom Area Cone Slant Length Cone Area ,._.~,-+42{~e.sS3(o.XE}+5.6~E)(S) Atoo(S+1.50)a D Ab G s c, c, E Wd t, As or Ap At 1.414(E) Slant Area Btwn 1/4 Cones Four Bolt Pattern 1·~~-~9 ' 1 Edge of Slab •·•. I ',.! -.- I i 12 12 0.65 0.5 A307 E + .750 sf ·.-.. ~. ~-~1-. -~ i Bp -i ········· .. . C , 1· --t-~ __ _,. ,:_· . 0 l I . I , ' I __ :t .. _____ ...... --"t··-""1-"".~--'" .. --.. --.. ~If C, > E then Use E ~···c; -.\.GJ, \ i Edge of Slab L_ If C, > E then UseE llnchor:..B.Qii.ld:!)'QY.l: Project Name: Jerry Hoffmeister 0.75 in. 0.44 sq. in. 4 in. 4 in. 12 in. 12 in. 12 in. 3 in. 4 No Yes 1 Normal Weight No Anchors Hooked Around Reba No Public Assm/Garage/LL> 1 OOp 2,500 psi 60,000 psi 12.56 in. 870.25 sq. in. 26 sq. in. 17 in. 700 sq. in. 271 sq. in. Project Control Number SHEET 1111111111111!11111111111111111111111111111111 * s s -0 3 1 7 3 * Factored Loads Loads are in Kips p v .9DL 1.30 0.34 1.2DL 1.73 0.46 Factored Load Combinations-Required Strength (1923.2 ) Use Load Factor Multiplier = 3 1909.2.1 U = (3)'(1.40+1.7L) 1909.2.2 U = (3)'(.75(1.40+1.7L+1.7W) 1909.2.3 L! = (3)'(.90+1.3W) 1612.4 (12·17) U (3).(1.20 + f1L + 1.0Em) 1612.4 (12·18) U = (3)•(.90 + 1.0Em) No Special Inspection Required 1.4DL 2.02 0.53 Bolts Embedded In Tension Zone Of Member Bolt Design Strength (1923.3.2) Minimum Design Strength (Tension) Pss = .9 Ab fu 1 Nb <1>Pc = <1>1>4Ap~f', Tension 1.7LL 8.14 2.69 Pu = 30.477 Pu = 3.81 Pu = ·15.53 95,378 # <1>Pc = 113,133 # > 15,534 OK Pu = 3,884 # Factored Tensile Load per bolt Pss = 28,283 # per bolt Pc = 174,050 Minimum Design Strength (Shear) Vss = .75 Ab fut Nb <1>Vc = <1> 800 Ab I> ~f', <1>Vc = 11,481 Vu = 5,276 # Factored Shear Load per anchor Vss = 19,870 #per bolt Vc = 17.663 Interaction 11<1> VuNc 0.46 $ 11<1> Pu/Pc 0.034 $ 11<1> [(Pu/Pc)~3+(VuNc)"''J 0.208 $ (Pu/Pc)2 +(VuNc)2 0.090 s 79,481 # OK OK OK OK 1.7WL ·8.47 ·4.64 Shear 1.3WL ·6.47 ·3.55 Vu = 9.65 Vu = ·3.20 Vu = ·9.62 Vu = 21.11 Vu = 12.62 Use (4) 3/4" Diameter Anchorbolts With A Minimum Of 12" Embeddment. No Special Inspection Required Project Control Number SHEET 1111111111!111~11111111111111111111111111111 Project Name: Jerry Hoffmeister * s s -0 3 1 7 3 * r-1/2" SHEETING DESCRIPTION ROOF SHEETING: 26 GA. HI-RIB COLOR: GA = Golvolume WAU. SHEETING: 26 GA. HI-RIB COLOR: SB = Stone Beige l"RIM COLOR: 'M-1 = 'Mlite 4 X-BRACING ANCHOR BOLT SETTING PLAN NOTE: All Base Plates At Elevation 100'-o· (Unless f"'""'!'---------.-x--------------------1 !:::,. THIS MANUFACTURER IS AN APPROVED FABRICATOR WITH THE FOLLOWING CERTl CATIONS. AISC CERTIFICATION, CATEGORY MB lAS i FA-192 Cli.Mll!IAMOioBli!NG BUREAU DIVISION 1 CLARK COUNTY, NV//#§'ZJ.I$SAN BERNARDINO COUNTY, CA/ I 236 Sl\'RI' BI!R!iKRlm(J).I,CQllm'QFct.E¥TJ.,.E236 CITY Of LOS ANGELES T'tPE I FABRICATOR / LWS / HSS / #1015 WedgCor, Inc. BUYER: CUST.' SHE : DESCRi ::S:S.OO' X 55.0 X 12.0 SCA!..E: NONE P.O. 'W3Q598 3.0;12 ORA'M4 BY: __ _ ...1L...1.f2§.. CHECK BY: __ _ ---'!L11E! DES. ENG.: __ ·_ SHEET NO. OF Cable Bracing Anchorage.xls Cable Bracing Anchorage Check Job Number: Engineer: Date: Cable Select tw fy fu fyeff Fexx weld Sw D Lw B b Theta Theta d L h Size Diameter (in) 5/16 3/8 1/2 in 50 ksi 65 ksi 60 ksi 70 ksi 0.1 in 0.0707 in in 4.9.38 in 2.2500 in 1:3440 ., in \'11 j,)iij\;;;!f~~f:(!J!{;~;;:;c[l degress · · 0.78540 . radians 3.00 in · 2.2500 in 0.9375 in Cable-Pu 1 Ultimate Allowable (kips) (kips) 11.20 5.60 15.40 7.70 26.90 13.45 5/16" = 1; 3/8" = 2; 1/2" = 3 thickness web plate of framing section yield stress of framing section ultimate stress of framing section effective yield strength classification strength of the weld metal size of fillet weld web -> flange effective throat thickness of the weld depth of framing section B + 2 * [d -(b/2)] *tan (30) length of flat base of hillside washer width of flat base of hillside washer vertical angle of angle bracing with web conversion anchorage distance to the nearest flange length of hole in framing section width of hole in framing section Punching Shear Fracture of the Web Plate Pu4 = kips Tensile Fracture of Web Plate Pus=· ·4!25), i · , kips Prepared by Richard K. Joyce 7/9/05 AISC6.9.7 February 07, 2008 Jerry Hoffmeister 4550 County Rd. 331 Silt, CO 81652 RE: 33' X 55' X 12' SHOP WEDGCOR, INC. ®P.O. Box 110-Jamestown, ND 58402-0110-(701) 252-7380 PO # W30598 Trujillo-Gus Dear Customer, This is to certify that the above referenced structure is being designed in accordance with the International Building Code 2003 for the following loads in addition to the dead load of the structure. a) ~ Roof Live Load""' 20 psf Tlibutary Reduction 0 Yes ~ Roof Snow Load = 40 psf 0 No (Ground Snow Load= 57.14 psfwith Ce = 1) Snow Imp.= 1 b) Wind Speed= 100 mph, Exposure C Wind Imp.= 1 c) Seismic Data Ss =0.457 Sl = 0.092 Site Class D Seismic Imp = 1 d) Collateral Load = l psf (Sprinkler, Insulation, Drop Ceiling) Others (Specify): e) Crane: Capacity= tons 0TR OUIH CMAA-Class C unless noted t) Mezzanine Size= LL= psf DL= psf g) Building Enclosure Type: § Enclosed Partially Enclosed Open 0 MONORAIL This certification is in accordance to the design loads you requested and specified in the purchase order agreement. The building is designed in accordance with AISC, ASD Ninth-Edition, AISI 2001 Edition, and MBMA Standard. WedgCor, Inc. makes no representations as to the adequacy of the design loads on the building components you have ordered. It is your responsibility to contact your city or county building officials to determine if the specified design loads you requested are adequate for your geographical area. If you are unfamiliar with the design loads required to obtain the necessary building permits, please contact your building official immediately and verify that the loadings you ordered are conect and in accordance with your building official's requirements for obtaining the necessary permits. WedgCor, Inc. limited warranty and engineering data are set forth in your PURCHASE ORDER, LIMITED WARRANTY and MANUFACTURER'S AGREEMENT. This certification covers parts manufactured by WedgCor, Inc. only and excludes such parts as doors, windows, masomy, foundation design and erection of the building. The building components not manufactured by WedgCor, Inc. are listed below: Material: N/ A Manufacturer's Name: N/A Fabricating Location: N/A The undersigned is not the engineer of record for the overall proje Sincerely, Jon Ekstrom, P.E. Registered Professional Engineer Enclosures: Limited Wananty Definitions and Common Practices Osha Safety Manual Calculations ENCANA1A 00001 UNCCa 03/20/08 08:17AM A0055160-00A NORM NEW STRT LREQ Ticket Nbr: A0055160-00A Original Call Date: 03/20/08 Time: 08:16AM Op: RMM Locate By Date : 03/24/08 Time: 11 :59 PM Meet: N Extended job: N State: CO County: GARFIELD City: SILT Addr: 4550 Street: COUNTY ROAD 331 Grids: 06S092W34** Legal: Y Lat!Long: 39.489075/-107.654009 39.489075/-107.651781 : 39.483124/-107.654009 39.483124/-107.651781 Type of Work: FOUNDATIONS Exp.: N Boring: N Location: LOC S/SD OF LOT *AREA IS PREMARKED WITH WHITE PAINT *ACCESS OPEN* Company: GERRY HOFFMEISTER H/0 Type: RESI Caller : GERRY HOFFMEISTER Phone: (970)876-2080 Fax: Email: HOFFY@SOPRIS.NET Done for: SELF Remarks: Members :BBRRT1 :ENCANA1A :HCEL01 :QLNCW05 '"" I MAP! .!liN I: •• IUF uiDIG lu• ... .1. I"' -r •• I •• --· ,., ·-· ' . --- ro ~ All A ~ ty ~ lOt 3, ~ I 1111" .. -I" ::Lo,c"'ae»to"'rs._N,_,_a,m...,.e,.,:..:::G::.:.R~E:.::G::..T.:.:A..:.Y!.!L:.::O::.:.R.:.._ ________________ Date: 3/20/2008 Indicates North D I I Signature of person on job site: ----------------------------- COLORADO STATE ELECTRICAL BOARD ELECTRICAL PERMIT NUMBER: 641409 IJ Date Paid: 19-MAR-08 Expires On: 19-MAR-09 Jl JERRY HOFFMEISTER 4550 CR 331 SILT, CO 81652 Daytime Phone: 970-876-2080 FAX: Power Supplier: HOLY CROSS -GLENWOOD SPRINGS Owner Name: JERRY HOFFMEISTER Address: 4550 CR 331 City: SILT, CO. 81652 RESIDENTIAL OTHER Registration Number: Trim Permit: N Driving Directions: at Silt tum south over the River, take first right turn (West) on Silt to Rifle Road, Take first left (South) onto Dryhollow rd, Drive aproximately 4 miles to 4550, Lbg house on east side of road Brief Description: New Storage/Garage building, I wm be installing a 100amp service to this new building from exsisting service and 2 lights and 1 CGI outlet in this new building. Inspector: Cyrus Tuchscher Cost of work: $1,000.00 For Inspection, Call: 970~25-5085 Fee Amount: $40.00 Paid COLORADO STATE ELECTRICAL BOARD DEPARTMENT OF REGULATORY AGENCIES 1560 Broadway. Suite 1500 Denver, Colorado 80202 Phone: (303) 894-2985 Parcel Detail Page 1 of4 Garfield County Assessor/Treasurer Parcel Detail Information Assess_or/Treasurer. Property Se.arch I Assessor Subset QJ!en' I Assess_or.Sales Search Clerk_&; RecorderR~tion Search Parcel Det!!il I Value Detail I Sales Detail I Residential/Commercial Im_p_rpvement Det<til Land Detail I Photographs I Tax Area II Account Number II Parcel Number II 2007 Mill Levy / I 023 II R023775 II 217934105005 II 45.551 I Owner Name and Mailing Address /HOFFMEISTER, KRIS & JERRY /4550 COUNTY ROAD 331 /SILT, CO 81652 Assessor's Parcel Description · (Not to be used as a legal description) /SECT,TWN,RNG:34-6-92 /SUB:CHIPPERFIELD ESTATES LOT:O /DESC: PARCEL 5 PRE:R023725 BK:0598 . /PG:0098 BK:0571 PG:0160 BK:1900 /PG:368 RECPT:23775 BK:1325 PG:848 /RECPT:596699 BK:l325 PG:847 /RECPT:596698 BK:0929 PG:0030 /BK:0871 PG:0201 BK:0871 PG:0200 /BK:0798 PG:0717 BK:0665 PG:0326 /BK:0663 PG:0232 BK:0652 PG:0721 Location Physical Address: 1/4558 331 COUNTY RD SILT Subdivision: IICHIPPERFIELD ESTATES II http:/ /www.garcoact.com/assessor/Parcel.asp? AccountNurnber=R023 77 5 1. I I I I I I I I 3/7/2008 Parcel Detail Page 2 of4 I Land Acres: 1115.08 I I Land Sg Ft: 110 I Section II Towns hi~ II Range I I 34 II 6 II 92 I 2007 Property Tax Valuation Information II Actual Value II Assessed Value I I Land: II 14s,oooll 11,5401 I Im~rovements: II 186,84011 14,8701 I Total: II 331,84011 26,4101 Sale Date: 11119/1995 Sale Price: 1132,000 Basic Building Characteristics Number of Residential 1 Buildings: Number of Commllnd lo I Buildings: I Residential Building Occurrence 1 Characteristics I I TOTAL HEATED AREA: IJ2,173 I II SINGLE F AM.RES-ABSTRACT CODE: }MPROVEMTS I ARCHITECTURAL STYLE: IIMANUF ACTURED I EXTERIOR wALL: IILOG I ROOF COVER: llcoMP SHNGL I I ROOF STRUCTURE: IIGABLE I I INTERIOR wALL: IIDRYWALL I I FLOOR: llsHT VINYL I I FLOOR: IICARPET I I HEATING FUEL: IlGAS I I HEATING TYPE: IIFORCED AIR I I STORIES: llsTORIES 1.0 I I BATHS: I 2 I ROOMS: Is http://www.garcoact.com/assessor!Parcel.asp? AccountNumber=R023 775 3/7/2008 Parcel Detail I UNITS: II I BEDROOMS: 13 I YEAR BUILT: 111997 I Tax Information Tax Year II Transaction Type II Amount I 2007 II Tax Payment: First Half II ($601.50}1 2007 II Tax Amount II $1,203.ool 2006 II Tax Payment: Second Half II ($505.54}1 2006 II Tax Payment: First Half II ($505.54}1 2006 II Tax Amount $1,011.081 2005 II Tax Payment: Second Half ($505.90}1 2005 II Tax Payment: First Half ($505.9021 2005 II Tax Amount $1,011.801 2004 II Tax Payment: Second Half ($537.72 2004 II Tax Payment: First Half ($537.72 2004 II Tax Amount $1,075.441 2003 II Tax Payment: Second Half I ($598.5621 2003 II Tax Payment: First Half ($598.5621 2003 II Tax Amount $1,197.121 2002 II Tax Payment: Second Half ($608.72 2002 II Tax Payment: First Half ($608.72 2002 II Tax Amount II $1,217.441 2001 II Tax Payment: Second Half II ($605.5421 2001 II Tax Payment: First Half II ($605.5421 2001 II Tax Amount II $1,211.081 2000 II Tax Payment: Second Half II ($615.1121 I 2000 II Tax Payment: First Half II ($615.11}1 I 2000 II Tax Amount II $1,230.221 I 1999 II Tax Payment: Second Half II ($612.19)1 I . 1999 II Tax Payment: First Half II ($612.1921 I 1999 II Tax Amount II $1,224.381 To];LpfPag~ Assessor Database Search Ontions I Treasurer Data]:Jase.Searph OQtions Clerk & Record\<rl2.atabase Search 0Qti9Jls http:/ /www.garcoact.com/assessor!Parcel.asp? AccountNurnber=R023 775 Page 3 of4 3/7/2008