HomeMy WebLinkAboutDesign & Installation Observation ReportsALL Ifillei 33 Four Wheel Drive Rd Carbondale, CO 81623 910.3094259 November 9, 2014 John Kuerston john(Q?kuerstenconstruction.com Onsite Wastewater Treatment System Vault Source Gas Spring Valley Compressor Station 6896 CR 115 Garfield County, Colorado OWTS Permit SEPT -9-13-2978 John, dc,L5 7\66F--s("t-),K Project No. C1109 ALL SERVICE septic, LLC has completed an onsite wastewater treatment system (OWTS) design for the a vault system that will serve an office building at 6896 CR 115, Garfield County, Colorado (Site). The property is located outside of Glenwood Springs, in an area where OWTSs are necessary. SITE CONDITIONS An office building has been constructed and is anticipated to be used by two employees. Water will be hauled to the Site and stored in a cistern located inside of the office building. The Site serves as a compressor station for Source Gas and has a significant amount of traffic and heavy equipment use. An OWTS was previously designed by Redi Engineering Services, LLC; however, due to complexities of the Site and high traffic in the area of the proposed soil treatment area (STA), the design has been re- evaluated and a vault recommended. DESIGN SPECIFICATIONS Numerous constraints in the area of the proposed STA include high voltage power lines, gas lines, heavy compaction of the proposed STA, and potential for heavy equipment and vehicle traffic over the STA. With those constraints in mind, we are recommending a vault installation. Use of the OWTS will be limited to an average of 2 employees per day. A toilet and lavatory will be the only plumbing fixtures in the office building. Minimum standards for a vault installation are outlined in 43.12 D. of Garfield County On -Site Wastewater Treatment System Regulations. We recommend installation of a Precast Concepts single -compartment 1500 -gallon, concrete septic tank with the outlet plugged for use as a vault. An audible and visual alarm must be installed to signal when the vault has filled to 75 -percent capacity. At that time, pumping must be coordinated. Pumping records should be maintained. If an H2O rated lid is not incorporated, we recommend installing bollards surrounding the septic tank to protect the tank from traffic. Cast iron manhole lids are also recommended due to the commercial nature of the Site. The component manufacturers are typical of applications used by contractors and engineers in this area, Alternatives may be considered or recommended by contacting our office. Construction must be Page 2 according to Garfield County On -Site Wastewater Treatment System Regulations, the OWTS Permit provided by Garfield County Building Department, and this design. LIMITS: All OWTS construction must be according to the county regulations. Requirements not specified in this report must follow applicable county regulations. The contractor should have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. Licensing of Systems Contractors may be required by county regulation. Please call with questions. Sincerely, ALL SERVICE septic, LLC £kCa_O 1&Ag Carla Ostberg, MPH, RENS Liability Clause: Under no circumstances whatsoever shalt the liability of ALL SERVICE septic, LLC, in connection with any contract, directly or indirectly, exceed the total amount paid by the client to ALL SERVICE septic, LLC for the services and/or goods which are the subject of the contract in connection with which the liability arises. €g€€_ 33551 - -3 Skilli gam j €I F 33€Fa 33:a3 fro MM M MQ MON NM sup OOIL Raabe NL MC OM 01111 OR lgb MOO 111 g 1 v 0 a v TANK ALERT° XT Alarm System Versatile, indoor or outdoor liquid level alarm system. This alarm system monitors liquid levels in lift pump chambers, sump pump basins, holding tanks, sewage, agricultural, and other non -potable water applications. The Tank Alert' XT indoor/outdoor alarm can serve as a high or low level alarm depending on the float switch model used. The alar horn sounds and the red beacon illuminates when a potentially threatening liquid level condition occurs. A "power on" Tight on the switch indicates power to the alarm panel FEATURES ■ Enclosure meets Type 3R water -tight standard. ■ Automatic alarm reset, horn silence switch, and alarm test switch 1 Alarm horn sounds at 85 decibels at 10 feet (3 meters). ■ Alarm system (when installed on separate circuit) operates even if pump circuit fails. ■ Complete package includes standard SJE SignalMasterm control switch with 15 feet (4.57 meters) of cable (other lengths available) and mounting clamp. ■ UL Listed for indoor or outdoor use. ■ CSA Certified. ■ Three-year limited warranty SINNA= SA IJL LR54?45 LISTEN 2a&X OPTIONS When ordered with the alarm, the system is available with: 1 altemate float switch models for high or low liquid level warning. ■ auxiliary dry normally open contacts for easy attachment of remote devices. ■ premounted terminal block so enclosure can also be used as a junction box for splicing pump, pump switch, and pump power Meets NEC standard for junction boxes. ■ 6 foot (1.8 meter) power cord and liquid -tight connectors SEE BACKSIDE FOR ORDERING INFORMATION. SEE PRICE BOOK FOR LIST PRICE. SPECIFICATIONS VOLTAGE: 120 VAC, 50/60 Hz ALARM ENCLOSURE: 6.5 x 4.5 x 3.0 inch (16.51 x 11.43 x 7.62 cm), indoor - outdoor, weatherproof, thermoplastic meets Type 3R water -tight standard ALARM HORN: 85 decibels at 10 feet (3 meters), meets Type 3R water -tight standard as installed by factory ALARM BEACON: UL Listed, Type 4x beacon assembly TEST/SILENCE SWITCH: certified to I P66 and IP68 standards AUXILIARYALARM CONTACTS(OPTIONAL): 120 VAC, 5 amps max., 50/60 Hz PRE -MOUNTED TERMINAL BLOCK (OPTIONAL): 20 amps, 120/230 VAC POWER CORD (OPTIONAL): 6 foot (1 8 meter) cord with 120 VAC plug FLOAT SWITCH: SJE SignalMasterecontrol switch with mounting clamp Cable: 15 feet (4 57 meters), flex bte 18 gauge, 2 conductor (UL) SJOW, water- resistant (CPE) Float: 2 74 inch d'ameter x 4.83 ;nch long (7 cm x 12 3 cm), high impact, corrosion resistant polypropy"ene housing for use in sewage and non - potable water up to 140°F (60°C) Maximum Water Depth: 30 feet (9 meters), 13 psi Electrical: 5 amps, 125 VAC/250 VAC, 50/60 Hz PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE • 1-218-847-1317 1-218-847-4617 Fax email. sje@sjerhombus.com wwwsjjerhombus.com 79 TAAN ALERT® XT Alarm System Versatile indoor or outdoor liquid level alarm system. ORDERING INFORMATION Shipping Weight STANDARD ALARM (120 VAC) Description Shipping Weight Part# 1009923 TAXT-01 H (120 VAC w/15' SJE SignalMaster° High Level) 3.00 lbs. 1010251 TAXI OIL (120 VAC w115' SJE SlgnalMastel° Low Level) 3.00 lbs. 1004442 TAXT-01H (120 VAC w/15' SJE Sensor Float° High Level) 3.00 lbs. 1005140 TAXT-01 L (120 VAC w/15' SJE Sensor Float° Low Level) 3.00 lbs 1005141 TAXI 01X (120 VAC no float) 1.50 lbs. STANDARD ALARM (120 VAC) with terminal block Shipping Weight Part# Description 1012416 TAXT--01 HAUXTB (120 VAC w/15' SJE SignalMaster'° High Level Auxiliary Contacts TB) 3 50 lbs 1022241 TART-01HTB (120 VAC w/15' SJE SignaMaster°High L eve&TB) 2,00 lbs 1005481 TAXT-01 HTB (120 VAC w/15' Sensor Float° High Level TB) 3.50 lbs. 1005835 TAXT-01 LTB (120 VAC w/15 Sensor Float• Low Level TB) 3.50 lbs. 1005836 TAXI 01XTB (120 VAC no float TB) 2.00 lbs. 1009214 TAXT-01 HAUXTB (120 VAC w/15 Sensor Float° High Level Auxiliary Contacts TB) 3.50 lbs. STANDARD ALARM (120 VAC) with options Shipping Weight Part# Desaipllon 1006850 TAXT-01 HAUX (120 VAC w/15' Sensor Float° High Level & Aux Con) 3.50 lbs 1006690 TAXT-01 HPC (120 VAC w/15' Sensor Float° High Level Power Cord) 3.50 lbs. H = High Level L = Low Level X = No Float TB = Includes Terminal Block PC = Power Cord AUX = Auxiliary Contacts MASTER CARTON holds 12 boxed units. SEE PRICE BOOK FOR LIST PRICE. SPECIFICATIONS VOLTAGE: 120VAC, 50/60 Hz ALARM ENCLOSURE: 6 5 x 4.5 x 3 inches (16.51 x 11,43 x 7.62 cm), indoor -outdoor, weatherproof, thermoplastic, meets Type 3R water -tight standard ALARM HORN: 85 decibles at 10 feet (3 meters), meets Type 3R water -tight standard as installed by factory ALARM BEACON: UL Listed, Type 4X beacon assembly TEST/SILENCE SWITCH: certified to 1P66 and IP68 standards AUXILIARYALARM CONTACTS (OPTIONAL): 120 VAC, 5 amps max , 50/60 HZ PRE -MOUNTED TERMINAL BLOCK (OPTIONAL): 20 amps, 120/230 VAC POWER CORD: (optional) 6 foot (1 8 meters) cord with 120 VAC plug FLOAT SWITCH: SJE SignalMaster° control switch with mounting clamp CABLE: 15 feet (4.57 meters)' flexible 18 gauge, 2 conductor (UL) SJOW, water-resistant (CPE) FLOAT: 2.74 inch diameter x 4.83 inch long (7 cm x 12.3 cm), high impact, corrosion resistant polypropylene -housing for use in sewage and non - potable water up lo 140°F (60°C) MAXIMUM WATER DEPTH: 30 feet (9 meters), 13 psi ELECTRICAL: 5 amps, 125 VAC/250 VAC, 50/60 Hz Call or fax your order! 1-888-DIAL-SJE (1-808-342-5753) If Fax 218-847-4617 80 OPTIONS CONTROLSWITCH OPTIONS The Tank Alert° XT alarm system comes standard with a 15 foot SJE SignalMaster° control switch with mounting damp Other float switches are available. See control switch section of the catalog. To determine the price of alarm with an alternate float, add the price of the part number with "no float" to the price of the float switch. UL Listed for Water &Sewage SIGNALIIO W UL5 P IJSIED uwus 2111 OTHER INFORMATION Option l Description AUX Auxiliary Alarm Contacts (installed) PC 6 foot power cord with two RCC8 1/2 inch liquid -tight connectors www.sjerhombus.com sje@sjerhombiis.com CatPagePN1018796L eSJE•Rhombus 05110 chi ing 0 o com z > C] Z X 4.0 am Z n oy > 0 to o m• m m m 1210d NOU.33 SS Div .Inti 1 b J OUTLET 7' 4•• �--a .D0 un tom! W P-- iy `ami -1 AC m M 0 N6 m w y to oma . D.4 r �O =a xz v 8 t>C3 4C CP o ° C D C7 D�5"o n -7.,„ o ua>. �� z oy v 23-0 0z xi 5 m c1, �i-u o �m 0 as � N ^�A 00 m Ao ZC O2 _o wr0 0 J 7 Holding Tank utyl Rubber Sealant *Meets ASTM C-1227 spec including C-1644-06 for resilient connectors • 6000 psi concrete • Delivered complete • Single compartment tank standard *'Available in all tank sizes Alarm System: • Variable float setting • 80% volume alarm standard • Weather proof panel 9 volt or 115 volt • 12" PVC riser standard Water $ (7'f 9) 399$764 Co. Rd 3'17 Wastewater P.O. Bac 925 �` PRECAST, Iac, ••. s:r:c%steu:sct. WFxbalt��:9)www3s5-3 valey precast72rBuena Vista, c m C081211O VALLEY Email: frontdesk©valleyprecastoom Andy Schwalier From: Herman Lucero <hlucero@hrlcomp.com> Sent: Monday, November 10, 2014 3:44 PM To: Andy Schwaller Cc: Green, Donald Subject: OTWS-SVCS Attachments: All Service Septic OWTS Vault Design.pdf Importance: High Andy; Per our telephone conversation, I have attached a report from Carla Ostberg (AII Service Septic), recommending a vault system at the Spring Valley Compressor Station located at 6896 CR 115 Glenwood Springs, Colorado. RMNG had previously permitted a septic system at the facility, Permit NO. SEPT -9-13-2978. Based on the report and recommendation for a vault system, HCSI, on behalf of RMNG, is requesting an amendment to ISDS Permit NO. SEPT -9- 13-2978. Upon approval from GARCO Community Development, HCSI will inform RMNG and construction contractor to proceed with installation of the vault system. Regards; Herman CJD Herman Lucero President r ) HRL Compliance Solutions. Inc. �•/ 2385 F 112 Road Grand Junction, CO 81505 lel 970.243 3271 mobile 970.261 3571 fax 970 2413280 website 1 vCard ; map I email co Confidentiality Note: This e•mait and any attachments are confidential and only for the use as authorized by HRL Compliance Solutions Inc. If you receive this message in error or are not the intended recipient, you should not retain, distribute, disclose or use any of this information. Permanently delete the e-mail and any attachments or copies. 1 ALL S!RYJC( 33 Four Wheel Drive Rd Carbondale, CO 81623 410389-5259 December 4, 2014 John Kuerston john@kuerstenconstruction.com Onsite Wastewater Treatment System Vault Installation Observation Source Gas Spring Valley Compressor Station 6896 CR 115 Garfield County, Colorado OWTS Permit SEPT -9-13-2978 John, Project No. C1109 ALL SERVICE septic, LLC observed the installation of the onsite wastewater treatment system (OWTS) on November 18 and December 1, 2014 for the subject Site, located at 6896 CR 115, Glenwood Springs, Colorado. The installation included a new 1500 -gallon, ingle-compartment Precast Concepts concrete septic tank with the outlet plugged for use as a vault. The pipe exiting the building was well -bedded and had a minimum of 2% slope to the vault. A clean-out was installed within 5 -feet of the building. The depth of the sewer pipe exiting the building was approximately 18 -inches below grade. We recommended Blue Board insulation over the pipe to protect the pipe from freezing. Bollards were installed around the septic tank to prevent any equipment or truck traffic over the septic tank. A float, set at 75% of tank capacity (approximately 40 -inches above the floor of the vault) was installed. A visual and audible alarm, located adjacent to the septic tank, will notify office personnel when tank needs to be pumped. Pumping records must be maintained. The OWTS was generally installed according to specifications. This observation is not a guarantee of workmanship and/or parts and materials. ALL SERVICE septic, LLC should be notified if changes are made to the OWTS in the future. Any additional OWTS construction must be according to the county regulations. LIMITS: Observations are limited to components that are visible at the time of the inspection. The installer must have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. The quality of the installation is dependent of the expertise of the installer, soil type, and weather conditions. Please call with questions. Sincerely, ALL SERVICE septic, LLC Carla Ostberg, MPH, REHS cc. Herman Lucero hlucero(@hrlcomo.com Donald Green Donald.ureen@sourcegas.com Matt Morgan matt.moruan@redi-eng.com Jeff Nelson jeff.nelson9280vahoo.com Tank being set Tank set and inlet pipe installed 40- II 1500 gallon Precast Concepts septic tank View of inlet pipe and clean out Inlet pipe inside septic tank Outlet hole plugged Backfill over tank with access to lids Bollards placed around tank Float for alarm inside septic tank Visual and audible alarm ao 0 0