HomeMy WebLinkAboutSoils ReportHuddleston -Berry Engineering & Testing, LLC GEOTECHNICAL INVESTIGATION 936 CRESCENT ROAD PARACHUTE, COLORADO PROJECT#01117-0002 FREEDOM CONSTRUCTION PO BOX 911433 ST. GEORGE, UTAH 84791 MARCH 7, 2012 Huddleston -Berry Engineering and Testing, LLC 640 White Avenue, Unit B Grand Junction, Colorado 81501 ,M'cf c'p7 SUMMARY OF CONCLUSIONS AND RECOMMENDATIONS A geotechnical investigation was conducted at 936 Crescent Road in Parachute, Colorado. The project location is shown on Figure 1 - Site Location Map. The purpose of the investigation was to evaluate the surface and subsurface conditions at the site with respect to foundation design, pavement design, and earthwork for the proposed construction. This summary has been prepared to include the information required by civil engineers, structural engineers, and contractors involved in the project. Subsurface Conditions (p. 2) The subsurface investigation consisted of four test pits, excavated on February 8`I, 2012. The locations of the test pits are shown on Figure 2 -- Site Plan. The test pits generally encountered fill materials above native lean clay soils. Groundwater was not encountered in the test pits at the time of the investigation. The native clay soils are slightly plastic and slightly collapsible. Summary of Foundation Recommendations • Foundation Type - Spread Footings or Monolithic Structural Slabs (p. 4) • Structural Fill - Minimum of 24 -inches below foundations. The native clay soils, exclusive of fill, may be reused as structural fill. Imported structural fill should consist of pit -run, CDOT Class 6 base course, or other granular material approved by the engineer.(p. 4) • Maximum Allowable Bearing Capacity - 1,500 psf. (p. 4) • Subgrade Modulus - 150 pci for native clay soil and 250 pci for pit -run, crusher fines, or base course. (p. 4) • Lateral Earth Pressure - 50 pcf (p. 5) Summary of Pavement Recommendations (p. 6) Automobile Parking Areas EDLA = 5, Structural Number = 2.75 ALTERNATIVE PAVEMENT SECTION (Inches) Hot -Mix Asphalt Pavement CDOT Class 6 Base Course CDOT Class 3 Subbase Course Rigid Pavement TOTAL Full Depth HMA 7.0 7.0 A 3.0 10.0 13.0 B 4.0 7,0 11.0 C 3.0 6.0 6.0 15.0 Full Depth RP 6.0 6.0 12.0 Truck Traffic Areas EDLA = 30. Structural Number = 3.70 ALTERNATIVE PAVEMENT SECTION (Inches) Hot-NIix Asphalt Pavement CDOT Class 6 Base Course CDOT Class 3 Subbase Course Rigid Pavement TOTAL Full Depth HMA 9.0 9.0 A 3.0 17.0 20.0 B 4.0 14.0 18.0 C 3.0 6.0 16.0 25.0 Full Depth RP 6.0 8.0 14.0 For gravel pavements, a minimum pavement thickness of 12 -inches is recommended. In addition, where heavy truck traffic is anticipated, a layer of Tensar TX140, or equivalent, geogrid is recommended below the gravel pavement. TABLE OF CONTENTS 1.0 INTRODUCTION 1 1.1 Scope 1 1.2 Site Location and Description 1 1.3 Proposed Construction 1 2.0 SUBSURFACE INVESTIGATION 2 3.0 LABORATORY TESTING 2 4.0 RECOMMENDATIONS 2 4.1 Foundations 2 4.2 Non -Structural Floor Slabs and Exterior Flatwork 3 4,3 Lateral Earth Pressures 3 4.4 Drainage 4 4.5 Excavations 4 4.6 Pavements 4 5.0 GENERAL 5 FIGURES Figure 1 — Site Location Map Figure 2 — Site Plan APPENDICES Appendix A — Typed Test Pit Logs Appendix B — Laboratory Testing Results 1.0 INTRODUCTION Huddleston -Ferry V,girr.ring3 rcii,,r. LLC As part of extensive development in Western Colorado, new commercial/industrial construction is proposed at 936 Crescent Road in Parachute. As part of the development process, Huddleston -Berry Engineering and Testing, LLC (HBET) was retained by Freedom Construction to conduct a geotechnical investigation at the site. 1.1 Scope As discussed above, a geotechnical investigation was conducted at 936 Crescent Road in Parachute, Colorado. The scope of the investigation included the following components: • Conducting a subsurface investigation to evaluate the subsurface conditions at the site. • Collecting soil samples and conducting laboratory testing to determine the engineering properties of the soils at the site. • Providing recommendations for foundation type and subgrade preparation. • Providing recommendations for bearing capacity. • Providing recommendations for lateral earth pressure. • Providing recommendations for drainage, grading, and general earthwork. • Providing recommendations for pavements. The investigation and report were completed by a Colorado registered professional engineer in accordance with generally accepted geotechnical engineering practices. This report has been prepared for the exclusive use of Freedom Construction and the Owner. 1.2 Site Location and Description The site is located at 936 Crescent Road in Parachute, Colorado. The project location is shown on Figure 1 — Site Location Map. At the time of the investigation, the site was generally open and fairly level with a slight slope down to the southwest. Vegetation at the site was minimal due to previous ground work, and consisted of tall weeds, brush and several medium sized trees located along shallow ditches. A small portion of a paved road was observed to dead end at the west boundary of the site. The property was bordered to the north by a shallow ditch, an existing business and Crescent Road, to the southeast by a shallow ditch and railroad tracks, and to the west by a moderate slope up to the 1-70 on-ramp. 1.3 Proposed Construction The proposed construction is anticipated to include an approximately 12,000 square -feet metal shop/office building, utility installation, and pavements. The proposed structure is anticipated to be constructed over a reinforced concrete foundation. W:12008 ALL RROJECTs101117 - Freedom Construction101117-0002 936 Crescent Rd1200 - Geo 101117-0007 R030712.doc 1 2.0 SUBSURFACE INVESTIGATION Huddleston -Berry Fhia[M.d�as re,14 ,1 LC The subsurface investigation was conducted on February 8th, 2012 and consisted of four test pits, excavated to depths of between 4.0 and 10.0 feet below the existing ground surface. The locations of the test pits are shown on Figure 2 — Site Plan. The test pits were located in the field relative to existing site features. Typed test pit logs are included in Appendix A. Samples of the native soils were collected using hand drive samplers and bulk sampling methods at the locations shown on the logs. As indicated on the logs, the subsurface conditions at the site were slightly variable. However, the test pits generally encountered 1.0 to 1.5 feet of fill materials above tan to brown to gray, dry to moist, medium stiff to very stiff lean clay with sand and sandy lean clay to the bottoms of the excavations. Groundwater was not encountered in the test pits at the time of the investigation. 3.0 LABORATORY TESTING Selected native soil samples collected from the test pits were tested in the Huddleston -Berry Engineering and Testing LLC geotechnical laboratory for natural moisture and density, grain size analysis, maximum dry density and optimum moisture (Proctor), Atterberg limits, swell/consolidation, and soluble sulfates content. The laboratory testing results are included in Appendix B. The laboratory testing results indicate that the native clay soils are slightly plastic. In addition, the native soils were shown to be slightly collapsible at their existing density with approximately 0.5% collapse measured in the laboratory. Water soluble sulfates were detected in the site soils in a concentration of 0.4%. 4.0 RECOMMENDATIONS 4.1 Foundations Based upon the results of the subsurface investigation and nature of the proposed construction, shallow foundations are recommended. Spread footings and monolithic (turndown) structural slabs are both appropriate alternatives. However, as discussed previously, the native soils were shown to be slightly collapsible. Therefore, to limit the potential for excessive differential settlements, it is recommended that the foundations be constructed above a minimum of 24 -inches of structural fill. The existing fill materials are not suitable for reuse as structural fill. However, the native clay soils are suitable for reuse as structural fill. Imported structural fill should consist of a granular, non -expansive, non -free draining material such as pit run, crusher fines, or CDOT Class 6 base course. However, if pit -run is used as structural fill, a minimum of six inches of Class 6 base course or crusher fines should be placed on top of the pit -run to prevent large point stresses on the bottoms of the foundations due to large particles in the pit -run. W:12003 ALL PROJECTS101117 - Freedom Construction101117-0002 936 Crescent Rd\200 - Caeo\011 17-0002 R030712.doc 2 Rudd1ecton-Berry En21*rrrin{S re•I4q.I1.0 Prior to placement of structural fill, it is recommended that the bottoms of the foundation excavations be scarified to a depth of 6 to 8 -inches, moisture conditioned, and re -compacted to a minimum of 95% of the standard Proctor maximum dry density, within 0 to -2% of the optimum moisture content as determined in accordance with ASTM D698. Structural fill should extend laterally beyond the edges of the foundation a distance equal to the thickness of structural fill. Structural fill should be moisture conditioned, placed in maximum 8 -inch loose lifts, and compacted to a minimum of 95% of the standard Proctor maximum dry density for fine grained soils or modified Proctor maximum dry density for coarse grained soils, within ±2% of the optimum moisture content as determined in accordance with ASTM D698 or D1557C, respectively. Pit -run materials should be proofrolled to the Engineer's satisfaction. For foundation building pads prepared as recommended with structural fill consisting of the native soils or imported granular materials, a maximum allowable bearing capacity of 1,500 psf may be used. In addition, a modulus of subgrade reaction of 150 pci may be used for structural fill consisting of native clay soils and a modulus of 250 pci may be used for structural fill consisting of pit -run, crusher fines, or base course. It is recommended that the bottoms of exterior foundations be at least 36 -inches below the final grade for frost protection. As discussed previously, water soluble sulfates were detected in the site soils in a concentration of 0.4%. This concentration represents a severe degree of potential sulfate attack on concrete exposed to these materials. Therefore, Type V sulfate resistant cement is recommended for construction at this site in accordance with the International Building Code (IBC). However, Type V cement can be difficult to obtain in Western Colorado. Where Type V cement is unavailable, a minimum of Type I-II cement is recommended. 4.2 Non -Structural Floor Slabs and Exterior Flatwork In order to limit the potential for movement of non-structural floor slabs, it is recommended that non-structural floor slabs be constructed above a minimum of 12 - inches of structural fill with subgrade preparation and fill placement in accordance with the Foundations section of this report. It is recommended that exterior flatwork be constructed above native soils, below the fill, that have been scarified to a depth of 9 to 12 -inches, moisture conditioned, and compacted to a minimum of 95% of the standard Proctor maximum dry density, within ±2% of optimum moisture content as determined in accordance with ASTM D698. 4.3 Lateral Earth Pressures Stemwalls and/or retaining walls should be designed to resist lateral earth pressures. For backfill consisting of the native soils or imported granular, non -free draining, non -expansive material, we recommend that the walls be designed for an equivalent fluid unit weight of 50 pcf in areas where no surcharge loads are present. Lateral earth pressures should be increased as necessary to reflect any surcharge loading behind the walls. V:12008 ALL PROJECTS 101117 - Freedom Construction101117-0002 936 Crescent Rd5200 - Geo101117-0002 R0307I2,doc 3 4.4 Drainage Huddleston -Berry tic Due to the presence of moisture sensitive soils at the site, proper site grading is critical to the performance of the structure. In order to improve the long-term performance of the foundations and slabs -on -grade, grading around the structure should be designed to carry precipitation and runoff away from the structure. It is recommended that the finished ground surface drop at least twelve inches within the first ten feet away from the structure. However, where impermeable surfaces (i.e. asphalt, concrete, etc.) are adjacent to the structure, the grade can be reduced to three inches within the first ten feet away from the structure. Downspouts should empty beyond the backfill zone. It is recommended that landscaping within five feet of the structure include primarily desert plants with low water requirements. In addition, it is recommended that automatic irrigation within ten feet of foundations be minimized or controlled with automatic shut off valves. 4.5 Excavations Excavations in the soils at the site may stand for short periods of time but should not be considered to be stable. Trenching and excavations should be sloped back, shored, or shielded for worker protection in accordance with applicable OSHA standards. The soils generally classify as Type C soil with regard to OSHA's Construction Standards for Excavations. For Type C soils, the maximum allowable slope in temporary cuts is 1.5H:1 V. 4.6 Pavements The proposed construction may include paved automobile parking areas and truck traffic areas. As discussed previously, the pavement subgrade materials consist primarily of lean clay soils. Therefore, the minimum recommended Resilient Modulus of 3,000 psi was used for the pavement design. Based upon the subgrade conditions and anticipated traffic loading, flexible and rigid pavement section alternatives were developed in accordance with the Guideline for the Design and Use of Asphalt Pavements for Colorado Roadways by the Colorado Asphalt Pavement Association and CDOT Pavement Design Manual. Gravel pavements were designed using the FHWA Gravel Roads, Maintenance and Design Manual. The following minimum pavement section alternatives are recommended: Automobile Parking Areas EDLA = 5, Structural Number = 2.75 ALTERNATIVE PAVEMENT SECTION (Inches) Hot -Mix Asphalt Pavement CDOT Class 6 Base Course CDOT Class 3 Subbase Course Rigid Pavement TOTAL Full Depth HMA 7.0 7.0 A 3.0 10.0 13.0 B 4:0 7.0 11.0 C 3.0 6.0 6.0 15.0 Full Depth RP 6.0 6.0 12.0 W:12008 ALL PROJECTS\01117 - Freedom Construction101117-0002 93 6 Crescent Rd\200 - Gea101117-0002 R030712doc 4 Truck Traffic Areas EDLA = 30, Structural Number = 3.70 Huddleston -Berry reincoi Lar..e;��y.i�.c ALTERNATIVE PAVEMENT SECTION (Inches) Hot -Mix Asphalt Pavement CDOT Class 6 Base Course CDOT Class 3 Subbase Course Rigid Pavement TOTAL Full Depth HMA 9.0 9.0 A 3.0 17.0 20.0 B 4.0 14.0 I8.0 C 3.0 6.0 16,0 25.0 Full Depth RP 6.0 8.0 14.0 For gravel pavements, a minimum pavement thickness of 12 -inches is recommended. In addition, where heavy truck traffic is anticipated, a layer of Tensar TX140, or equivalent, geogrid is recommended below the gravel pavement. Prior to pavement placement, areas to be paved should be stripped of all topsoil, fill, or other unsuitable materials. It is recommended that the subgrade soils be scarified to a depth of 12 -inches; moisture conditioned, and recompacted to a minimum of 95% of the standard Proctor maximum dry density, within 0 to -2% of optimum moisture content as determined by AASHTO T-99. Aggregate base course and subbase course should be placed in maximum 9 -inch loose lifts, moisture conditioned, and compacted to a minimum of 95% and 93% of the maximum dry density, respectively, at -2% to +3% of optimum moisture content as determined by AASHTO T-180. In addition to density testing, base course should be proofrolled to verify subgrade stability. It is recommended that Hot -Mix Asphaltic (HMA) pavement conform to CDOT grading SX or S specifications and consist of an approved 75 gyration Superpave method mix design. HMA pavement should be compacted to between 92% and 96% of the maximum theoretical density. An end point stress of 50 psi should be used. It is recommended that rigid pavements consist of CDOT Class P concrete or alternative approved by the Engineer. In addition, pavements should conform to local specifications. The long-term performance of the pavements is dependent on positive drainage away from the pavements. Ditches, culverts, and inlet structures in the vicinity of paved areas must be maintained to prevent ponding of water on the pavement. 5.0 GENERAL The recommendations included above are based upon the results of the subsurface investigation and on our local experience. These conclusions and recommendations are valid only for the proposed construction. W:12008 ALL PROJECT$101117 - freedom Constroction,61117-0002 936 Crescent Rd5200 - Geo101117-0002 R030712.doc 5 Huddleston -Berry F ,.M.71e.,,t Ie.r.0„, ILC It is important to note that the recommendations provided in this report are intended to reduce, but not eliminate, the potential for structural movement as a result of collapse of the native soils. While the recommendations are consistent with generally accepted engineering practices in areas of moisture sensitive subgrade materials, HBET cannot predict long-term changes in subsurface moisture conditions and/or the precise magnitude or extent of volume change. Although the potential for movement still exists, HBET believes that with proper application of the recommendations in this report, any structural movements will be within acceptable levels. As discussed previously, the subsurface conditions at the site were slightly variable. However, the precise nature and extent of subsurface variability may not become evident until construction. Therefore, it is recommended that a representative of HBET be retained to provide engineering oversight and construction materials testing services during the foundation, earthwork, and pavement phases of the construction. This is to verify compliance with the recommendations included in this report or permit identification of significant variations in the subsurface conditions which may require modification of the recommendations. Huddleston -Berry Engineering and Testing, LLC is pleased to be of service to your project. Please contact us if you have any questions or comments regarding the contents of this report. Respectfully Submitted: Huddleston -B; ry Engineering and Testing, LLC Michael A. Berry, P.E. Vice President of Engineering W.i2008 ALL PROJECT5101117 - Freedom Construction101 1 17-0002 936 Crescent Rdh2C4 - Geo \0i l t 7-0002 R030712.dac 6 FIGURES r ))%.--,' iomr tk Lf v- ���7 1`ti\��\ \ t4., iii `5'c \\_.,\L J v ( t- : '', -q yy'i\/ t t 3 _,.,?‘„,„ .to. ��Y�77� % , x\M1 1, it O !1 5164J X 5820 M5 Water X5500 fJ 0 a ttlement 13 5074 a r Battlemien Sch r - 5056X n0 5245 USGS Parachute, Colorado Quadrangle, 7.5 Minute Series, 1962. \ FIGURE 1 Site Location Map '�':A9 .ii♦jj :04:ri47933'47r.r..t.rrr- ei��•} eiIN�!.:•.i oc.vxu�bairruarroau�wm+esa.SO Z2 2%;9 5, ,, re evyr A= *ia - DiPioP4 •w4.Oi a . :❖:•••:4 44.D>iOauawvi3a�a3lHvn i•.`••.4•••••4••••+.,..Pe h4p�.•�.•• ••;;•;L:❖4:.'•: APPENDIX A Typed Test Pit Logs oNege,� ti N --co0 CLIENT PROJECT Huddleston -Berry Engineering R Testing, LLC , 640 White Avenue, Unit B 13Grand Junction, CO 81501 970-255-8005 970-255-6818 Freedom Construction PROJECT NAME LOCATION TEST PIT NUMBER TP -1 PAGE 1 OF 1 936 Crescent Road NUMBER 01117-0002 PROJECT Parachute, CO DATE EXCAVATION EXCAVATION LOGGED NOTES STARTED BY 2/8/12 COMPLETED 2/8/12 GROUND ELEVATION WATER LEVELS: TIME OF EXCAVATION END OF EXCAVATION EXCAVATION TEST PIT SIZE CONTRACTOR Tally Hoe GROUND --- dry METHOD Trackhoe AT AS CHECKED BY MAB AT dry AFTER o DEPTH o (ft) GRAPHIC LOG MATERIAL DESCRIPTION SAMPLE TYPE NUMBER RECOVERY % (RQD) BLOW COUNTS (N VALUE) POCKET PEN. (tsf) DRY UNIT WT. (Pef) MOISTURE CONTENT (%) ATTERBERG LIMITS FINES CONTENT (%) LIQUID LIMIT PLASTIC LIMIT PLASTICITY INDEX n•*•: iri LEAN CLAY with Sand, Organics, Debris and Asphalt (FILL), trace gravel, dark brown, tan and black, dry to moist, medium stiff 2.5 /stiff LEAN CLAY with Sand (CL), with bedded gravel lenses, tan, reddish brown, gray and yellowish brown, dry to moist, medium to stiff, abundant sulfates N MC 98 10 5.0 - . GB1: Lab Classified GB 9 27 14 13 78 7.5 Bottom of test pit at 8.0 feet. M 1- 0 0 1- z z EL req ID0 z w w w U rn 0 O 9 1- 0 0 z 2 0 U 2 00 2 U w 0 0 w 0 E�[_¢NEFgi, ,, ::=eo CLIENT PROJECT Huddleston -Berry Engineering &Testing, LLC , 640 White Avenue, Unit B „ Grand Junction, CO 81501 970-255-8005 970-255-6818 Freedom Construction PROJECT NAME LOCATION TEST PIT NUMBER TP -2 PAGE 1 OF 1 936 Crescent Road NUMBER 01117-0002 PROJECT Parachute, CO DATE EXCAVATION EXCAVATION LOGGED NOTES STARTED BY 2/8/12 COMPLETED 218112 GROUND ELEVATION WATER LEVELS: TIME OF EXCAVATION END OF EXCAVATION EXCAVATION TEST PIT SIZE CONTRACTOR Tally Hoe GROUND --- dry METHOD Trackhoe AT AS CHECKED BY MAB AT dry AFTER 1 o_ 0 0 GRAPHIC jLOG MATERIAL DESCRIPTION SAMPLE TYPE NUMBER RECOVERY % (ROD) BLOW COUNTS (N VALUE) POCKET PEN. (tsf) DRY UNIT WT. L (pef) MOISTURE CONTENT (%) ATTERBERG LIMITS FINES CONTENT (%) LIQUID LIMIT PLASTIC LIMIT PLASTICITY INDEX 1 .:e 4'. ♦t ♦t •�••• • i•••• •• • • � ••• •••••• *04 Sandy LEAN CLAY with Organics and Debris (FILL), trace gravel, reddish brown, dry to moist, medium stiff 2 Sandy LEAN CLAY (cl), with bedded gravel lenses, reddish brown to tan, dry to moist, medium stiff to stiff, abundant sulfates 3 :!/ 4 Bottom of test pit at 4.0 feet. 0 z 0 0 rr z z W U uJ W U rn N 0 0 0 7-7ti 0 0 z 0 0 2 CD Z 0 0 O W 0 G," "` , yO :_ CLIENT PROJECT ,,,"� Huddleston-640WhiteBent' EngineerBing & Testing, LLC Avenue, Unit , Grand Junction, CO 81501-1B1 970-255-8005 cot's 970-255-6818 Freedom Construction PROJECT NAME LOCATION TEST PIT NUMBER TP -3 PAGE 1 OF 1 936 Crescent Road NUMBER 01117-0002 PROJECT Parachute, CO DATE EXCAVATION EXCAVATION LOGGED NOTES STARTED BY 2/8/12 COMPLETED 2/8112 GROUND ELEVATION WATER LEVELS: TIME OF EXCAVATION END OF EXCAVATION EXCAVATION TEST PIT SIZE CONTRACTOR Tally Hoe GROUND --- dry METHOD Trackhoe AT AS CHECKED BY MAB AT dry AFTER DEPTH (ft) GRAPHIC LOG MATERIAL DESCRIPTION SAMPLE TYPE NUMBER RECOVERY % (RQD) BLOW COUNTS (N VALUE) POCKET PEN. (tsf) DRY UNIT WT. (pcf) MOISTURE CONTENT(%) ATTERBERG LIMITS FINES CONTENT i (%) J LIQUID LIMIT PLASTIC LIMIT PLASTICITY INDEX O4Oi. 9;*. • ••••••• i%%• i Sandy LEAN CLAY with Organics , Debris and Asphalt (FILL), reddish brown, black and tan, moist, medium stiff i1Jf$ 2 f � . Sandy LEAN CLAY (cl), with bedded gravel lenses, reddish brown, brown, tan and gray, moist, medium stiff, abundant sulfates 3 4 Bottom of test pit at 4.0 feet. N $- O C7 m 0 0 0 re z U 0 re 0(0rn N 00 9 z 2 J O U x x U W F O W �1NEFR 1-113 �. -e CLIENT PROJECT Huddleston -Berry Engineering & Testing, LLC ,o 640 White Avenue, Unit B , Grand Junction, CO 81501 s`970-255-8005 '� 970-255-6818 Freedom Construction PROJECT NAME LOCATION TEST PIT NUMBER TP -4 PAGE 1 OF 1 936 Crescent Road NUMBER 01117-0002 PROJECT Parachute, CO DATE EXCAVATION EXCAVATION LOGGED NOTES STARTED BY 218112 COMPLETED 2/8/12 GROUND ELEVATION WATER LEVELS: TIME OF EXCAVATION END OF EXCAVATION EXCAVATION TEST PIT SIZE CONTRACTOR Tally Hoe GROUND --- dry METHOD Trackhoe AT AS CHECKED BY MAB AT dry AFTER 1 a 0 0.0 GRAPHIC LOG MATERIAL DESCRIPTION SAMPLE TYPE NUMBER RECOVERY % (ROD) BLOW COUNTS (N VALUE) POCKET PEN. (tsf) 2 a >- Ce 0 MOISTURE CONTENT (c/o) ATTERBERG LIMITS FINES CONTENT (%/O) LIQUID LIMIT PLASTIC LIMIT PLASTICITY INDEX ,:a Sandy LEAN CLAY with Organics, Debris and Gravel (FILL), :•:•: brown, dry, medium stiff •••i APPENDIX 13 Laboratory Testing Results 0 m Z 0 cc ccz W U W U 0 s w N 0, z `" '' *:-. CLIENT �µEfq�� 600 ° ` $ Freedom Huddleston -Berry Engineering R Testing, LLC GRAIN SIZE DISTRIBUTION 640 White Avenue, Unita Grand Junction, CO 81501 970-255-8005 970-255-6818 Construction PROJECT NAME 936 Crescent Road PROJECT NUMBER 01117-0002 PROJECT LOCATION Parachute, CO U.S. SIEVE OPENING 6 4 3 2 IN INCHES 1 314 112` 1 U.S. SIEVE NUMBERS I HYDROMETER 3 3 4 6 810 1416 20 30 40 50 60 1010140200 100 1 ;. I T I I I I 95 .H • 1L-N\\ 90 .E 85 ,•1 S_ -- 80 H ., M 75 ;, H 70 HI 65 H r O 60 w >-m 55 ce w 50 z L H 45 z w cew 40 0 35 - 30 25 20 15 10 5 0 100 10 1 0 1 0.01 0.001 GRAIN SIZE IN MILLIMETERS GRAVEL SAND SILT OR CLAY COBBLES coarse fine coarse medium fine Specimen Identification Classification LL PL PI Cc Cu • TP -1 GB -1 2/2012 LEAN CLAY with SAND(CL) 27 14 13 II TP -4 GB -1 2/2012 SANDY LEAN CLAY(CL) 26 15 11 Specimen Identification D100 D60 D30 D10 %Gravel %Sand %Silt %Clay • TP -1 GB -1 2/2012 9.5 0.4 21.1 78.5 1 TP -4 GB -1 2/2012 37.5 0.107 12.0 34.1 53.9 ATTERBERG LIMITS 01117-0002 936 CRESCENT RD.GPJ GINT US LAB.GDT 312112 CLIENT ,,'.. ko.•_ °, Eli R Huddleston -Berry Engineering &Testing, LLC ATTERBERG LIMITS' RESULTS " 640 White Avenue, Unit B Grand Junction, GO 81501 � 970-255-80(15 cod's 970-255-6818 Freedom Construction PROJECT NAME 936 Crescent Road PROJECT NUMBER 01117-0002 PROJECT LOCATION Parachute, CO 60 CICH 50 P L A s 40 T I C T 30 Y I N 20 D E X 10 • m CL -ML S MH 0 20 40 60 80 100 LIQUID LIMIT Specimen Identification LL PL PI #200 Classification • TP -1 GB -1 2/2012 27 14 13 78 LEAN CLAY with SAND(CL) m TP -4 GB -1 212012 26 15 11 54 SANDY LEAN CLAY(CL) 01 0, H 1- z 0 0 0 1- z Z w co w U 01 01 0 R n 0 ate' J 0 N Z 0 0 �N CLIENT ,f?F :- c" ,�, �', 5 Freedom Huddleston -Berry Engineering & Testing, LLC CONSOLIDATION TEST 640 White Avenue, Unit B 9Grand70-255-8005 Junction, CO 81501 970-255-6818 Construction PROJECT NAME 936 Crescent Road PROJECT NUMBER 01117-0002 PROJECT LOCATION Parachute, CO 0 1 • 2 3 4 z 5 6 7 8 9 10 100 1,000 10,000 STRESS, psf Specimen Identification Classification Yd MC% • TP -1 2.0 98 10 N N M 0 04 (79z a C9 0 1- z z w U on U co N 0 0 O r- 0 0 z 0 U CLIENT coy°' Huddleston -Berry Engineering & Testing, LLC CONSOLIDATION TEST 640 White Avenue, Unit B Grand Junction, CO 81501 970-255-8005 970-255-6818 Freedom Construction PROJECT NAME 936 Crescent Road PROJECT NUMBER 01117-0002 PROJECT LOCATION Parachute, CO 0.0 • 0.5 1.0 1.5 2.0 2.5 0 3.0 3.5 4.0 4.5 5.0 5.5 60 100 1,000 10,000 STRESS, psf Specimen Identification Classification Yd MC% • TP -4 1.5 100 8 • 0 0 c� 4 z 0 0 0 Uce 0 z W U ro m 0 0 Z 0 U D. U ceEF,q, eot"`r CLIENT PROJECT ' Freedom Huddleston -Berry Engineering & Testing, LLC 640 White Avenue, Unit B Grand Junction, CO 81501 - 970970-255-6818255-8005 Construction MOISTURE PROJECT NAME PROJECT LOCATION -DENSITY RELATIONSHIP 936 Crescent Road NUMBER 01117-0002 Parachute, CO DRY DENSITY, pcf _, _, _1 _, 3 3 C-') o Cn O (71 0 (1 0 c3 0 01 O [mit 0 Sample Sample Source Description Test Maximum Optimum of Method: Date: No.: Material: of Material: Dry Water TEST Density Content GRADATION #200 218/2012 1 TP -4 SANDY LEAN CLAY(CL) ASTM D698A RESULTS ATTERBERG RESULTS 117.2 PCF % (% LIMITS 100% Gravity 2.80 2.70 2.60 PASSING) 314" 13.2 #4 88 54 97 LL Curves for PL PI to: 26 15 Specific of 11 Saturation Equal 5 10 15 20 25 30 WATER CONTENT, %