Loading...
HomeMy WebLinkAboutApplicationd rc[ Qi So -v\ CM c " (0SO - z� 108 8th Street, Suite 401, Glemvood Springs, CO 81601 Ph:970-945-8212 Fx:970-384-3440 Inspection Line:888-868-5306 www.garfield-countv.com BUILDING PERMIT APPLICATION GARFIELD COUNTY e_.2 BUILDING & PLANNING 1 Parcel No: (this information is available al the assessors office 970-945-9134) IY a 1 0l2 000 2. -CP Lot No: Block No: Subd./ Exemption: 2 Job Address: (ifan address hats 770( been assigned, pleases provide CR, FIWY or Street Name & City) or and legal description A , avv� �T^ L.C►1 N.a-•, 3 Owner: (property owner fT7CJ.tr_-v_ -j c.V-S Mailing Address: 7Cg© 2.(491f1.. (2 -a -a Ph: 070 7 -(yd - 4,501 Alt Ph: 1Contractor: 3t4 1017-4'e(5001 re.44 Co lAS%+rVC.14Cr,, Mailing Address: 'P.c. L o x11`#33 Ph: 435 ?VG- PZ13 Alt Ph: 5 Manufactured home installer: Mailing Address: h: Lic #: 6 Architect: Cv10u4tirG L�e,svvi...s M ' ' ' ` ddress: ol-, • , fl 'oy 217 Iblo : (135)(44% - 2228 Alt Ph: 7 Engineer: V teA-o r Mailing Address: v, Ti 0 clot/ 2.2o 51-‘ Ci.v+1', Ph: (tin)424 -5122- Alt Ph: 8 Sq. Ft. of Building: Sq. Ft. or Acres of Lot: Height: Z3r/0H No. of Floors: 1 9 Use of Building: ❑Residential IaCommercial ❑Other Class of Work: Slew ❑Alteration ❑Addition ❑Repair ❑Demo OMove 10 Describe Work: rintkft1 Stx tai 11 Garage:"Septic: ❑Attached ❑Detached (e1SDS ❑Community Type of Heat: :Nat. Gas ❑I ropane ❑Electric ❑Other 12 / Driveway Permit: axe-/oF Owners vi ff eyev Work: a NOTICE Authority, This application for a Building Permit must be signed by the Owner of the property, described above, or an authorized agent If the signature below is not that of the Owner, a separate letter of authority, signed by the Owner, must be provided with this Application. Legal Access A Building Permit cannot be issued without proof of legal and adequate access to the property for purposes of inspections by the Building Department. Other Permits, Multiple separate permits may be required: (1) State Electrical Permit, (2) County ISDS Permit, (3) another permit required for use on the property identified above, e.g. State or County Highway/ Road Access or a State Wastewater Discharge Permit. Void Permit. A Building Permit becomes null and void if the work authorized is not commenced within 180 days of the date of issuance and if work is suspended or abandoned for a period of 180 days after commencement. CERTIFICATION 1 hereby certify that 1 have read this Application and that the information contained above is true and correct. I understand that the Building Department accepts the Application, along with the plans and specifications and other data submitted by me or on my behalf (submittals), based upon my certification as to accuracy. Assuming completeness of the submittals and approval of this Application, a Building Permit will be issued granting permission to me, as Owner, to construct the structurc(s) and facilities detailed on the submittals reviewed by the Building Department_ In consideration of the issuance of the Building Permit,1 agree That land my agents will comply with provisions of any federal, slate or local law regulating the work and the Garfield County Building Code, ISDS regulations and applicable land use regulations (County Regulation(s)). 1 acknowledge that the Building Permit may be suspended or revoked, upon notice from the County, if the Location, construction or use of the structure(s) and facility(ies), described above, are not in compliance with County Regulation(s) or any other applicable law. 1 hereby grant permission 10 the Building Department to enter the property, described above, to inspect the work. 1 further acknowledge that the issuance of the Building Permit does not prevent the Building Official from: (I) requiring the correction of errors in the submittals, if any, discovered atter issuance; or (2) stopping construction or use of the structures) or facility(ies) if such is in violation of County Regulation(s) or any other applicable law. Review of this Application, including submittals, and inspections of the work by the Building Department do not constitute an acceptance of responsibility or Liability by the County of errors, omissions or discrepancies. As the Owner, I acknowledge that responsibility for compliance with federal, state and local laws and County Regulations rest with me and my authorized agents, including without limitation my architect designer, engineer and/ or builder. I HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE NOTICE & CERTIFICATION ABOVE: 2A/0/J' `r 2i!/ tV ii / 41// OWNERS SIGNATURE DATE STAFF USE ONLY Special Conditions: Adjusted Valuation: 7V6i/S/.B8 Plan Check Fee: 2861.5,5 Permit Fee: q107.00 Manu home Fee: 1 Misc Fees: ..----- Total Fees: `7271. s', Fees Paid: /757.9'4 Balance Due: ,x,.553 . b1 BP No & issue Date: ISDS No & Issued Date: SEN. -WO -1 di 3d, Setbacks: t--: 2:5'R 1/ 510' OCC Group: F1, �A S I Const Type: 'A, Zoning: l? L.__ BLD 'Di' 9/./5,7_ 171/ 7 PPP OVAL DATEAl. 'R.OVAL DATE Callahan Comm, Park, LLC/Barry Hicks Callahan Court, Parachute 4/3/2012 FI Accessory S B SI Applicant Address Date VALUATION FEE DETERMINATION Subdivision Lot/Block Contractor Finished (Livable Area): Main sq.ft Upper sq.ft Lower sq.ft Other sq.ft X 874.68 Total Square Feet 0 sq.ft Total Valuation Basement: Unfinished Conversion of Unfinished to Finished Other Total Valuation Garage/Storage (wood framed) Conversion of garage to finished living Carport Other Total Valuation Crawl Space Total Valuation Decks/ Patios/Porches Covered Open Other Total Valuation Type of Construction: VA, VB Occupancy: Total Valuation Total Valuation sq.ft X $41.00 sq.ft X $33.68 sq.ft X sq.ftX $18.00 sq.ft X $56.68 sq.ft X $12.00 sq.ft X sq.ft X $9.00 sq.ft X $24.00 sq.ft X 812.00 sq.ft X Commercial 8399 778 2866 2080 sf X sf X sf X sf X sf X sf X 847.42 839.88 $81.61 $39.88 Callahan Commercial Park N/A Freedom Construction, Sam Torgerson 0.00 0.00 0.00 0.00 0.00 746,151.88 746,151.88 Building Plan Review Description of Work: Metal Building Bin #: Location Address: 169 CALLAHAN CT PARACHUTE, CO General Information Contacts Case Manager: David Bartholomew Plan Case Number: BLDG -12-11-7100 Parcel: 240707200026 Application Date: 12121/2011 Owner: Berry Applicant: Berry Applicant Phone: (970)260-4501 Email: Building Planning/Zoning Engineered Foundation / Property Line Setbacks Driveway Permit 30ft Stream Setbacks Surveyed Site Plan / Flood Plain Septic Permit and Setbacks Building height Grade!Topography 30% Toning Sign -off 7 Attach Residential Plan Review List A-` Road Impact Fees ,114 r} Minimum Application Questionnare �` HOAIDRC Approval / Subdivision Plat Notes / Grade/Topography 40% Fire Department Review lanning Issues / Valuation Determination/Fees Subdivision Plat / Red Line Plans/Stamps/Sticker General Comments: 7 Attach Conditions pplication Signed Pian Reviewer To Sign Application Parcel/Schedule No. 13/4 40# Snowload Letter - Manu. Homes Soils Report Tuesday, April 3, 2012 CONDITIONS OF PERMIT BLCO-12-11-2322 Callahan Commercial Park Metal Fabrication Shop, Office, Storage Callahan Court Parachute, Colorado 1) ALL WORK MUST COMPLY WITH THE 2009 IBC, IMC, IPC, IFGC, IECC, IFC, AND THE MANUFACTURERS INSTALLATION SPECIFICATIONS. 2) ALL WORK SHALL COMPLY WITH USES PERMITTED IN THE "CL" ZONE DISTRICT. 3) BUILDING IS APPROVED AS TYPE 5B CONSTRUCTION, B AND 51 OCCUPANCY. 4) BUILDING IS APPROVED AS TYPE 5A CONSTRUCTION, F1 OCCUPANCY. 5) LOCAL FIRE DISTRICT SHALL INSPECT FIRE EXTINQUISHERS, ALARMS, AND OTHER PERTINENT IFC REQUIREMENTS. FIRE DISTRICT FINAL APPROVAL LETTER IS REQUIRED FOR CERTIFICATE OF OCCUPANCY. 6) MAXIMUM ALLOWABLE QUANTITY OF FLAMMABLE AND COMBUSTIBLE MATERIALS PER 2009 IBC, SECTION 414 AND 2009 IFC, CHAPTER 27. 7) ALL HIGH STRENGTH BOLTING AND FIELD WELDING REQUIRES SPECIAL INSPECTOR. FINAL APPROVAL REPORT IS REQUIRED AT FRAME INSPECTION. 8) ACCESSIBILITY REQUIREMENTS PER 2009 IBC, CHAPTER 11, AND ICC/ANSI A117.1-2003. 9) LOCKS, LATCHES, AND LANDINGS PER 2009 IBC, SECTION 1008. 10) LIGHT AND VENTILATION PER 2009 IBC, CHAPTER 12. 11) VERIFY EXIT DIRECTIONAL SIGNAGE PRIOR TO ELECTRICAL ROUGH -IN INSPECTION. 12) ELECTRICAL ROUGH IN APPROVAL IS REQUIRED PRIOR TO FRAME INSPECTION. 13) ELECTRICAL FINAL APPROVAL IS REQUIRED FOR CERTIFICATE OF OCCUPANCY. 14) GARFIELD COUNTY FINAL INSPECTION REQUIRED FOR CO/FINAL APPROVAL. ,c/ & c°f v NOTE: If any required information is missing, delays in issuing the permit are to be expected. If determined by the Building Official that additional information is necessary to review the application and/or plans for compliance, the application may be placed on hold until the required information is provided. Work may not proceed without the issuance of a permit. The building department will collect a Ran Review fee at time of application submittal. The Permit Fee, as well as any Septic or Road Impact fees will be collected when the permit is issued. The permit application must be signed by the owner or by a person having written authority from the owner to act as their representative. I hereby acknowledge I have read, understand, and will abide with the requirements of this checklist. j‘ger Signature of Owner Date Garfield County Building & Planning 108 8th Street, Suite 401 Glenwood Springs, CO 81601 Phone: 970-945-8212 Fax: 970-384-3470 www.garfield-county.com