HomeMy WebLinkAboutApplicationRiC11 / P31,1 Garfield County GARFIELD C' iTity Development Department MMt NT( IE)EVEL 108 8th Street, Suite 401 Glenwood Springs, CO 81601 (970) 945-8212 www.earfield-count-v.com TYPE OF CONSTRUCTION O Commercial/Multi-Family O Manufactured Horne (SF or Duplex) ❑ Residential (SF, Duplex, or Townhome) El Reroof BUILDING PERMIT APPLICATION 0 Demolition INVOLVED PARTIES Property Owner: Pat Higgins/�k oW=0.-.T001 Phone: ( 307 ) 631-6653 Mailing Address: 1111 Dunn Ave, Cheyenne. WY 82001 Contractor: RTN Roofing Systems, LLC Phone: [ 970 ) 593-1100 Mailing Address: 5854 Lockheed Ave, Loveland, CO 80538 Architect: Phone: ( Mailing Address: Engineer: Phone: ( ) Mailing Address: Manufactured Home Installer. Phone: ( Mailing Address: PROJECT NAME AND LOCATION Describe Work: Install approx. 21 squares of Duro-Last roofing material. See attached scope of work for details. Job Address: 4919 Hwy 82, Glenwood Springs, CO 81601 Assessor's Parcel Number: Sub. Lot Owner's Valuation of Work: $ 15,508.00 Property Size (Sq.Ft or Acres): Block Sq.Ft of Building: Height: # of Floors: Class of Work: 0 New 0 Alteration 0 Addition 0 Repair 0 Move/Relocation Garage: 0 Attached 0 Detached Septic: 0 ISDS 0 Community i Type of Heat: 0 Natural Gas 0 Propane 0 Electric 0 Other Driveway Permit: 0 Exempt 0 Permit #: NOTICE Authority. This application for a Building Permit must be signed by the Owner of the property, described above, or an authorized agent. If the signature below is not that of the Owner, a separate letter of authority, signed by the Owner, must be provided with this Application. Legal Access. A Building Permit cannot be issued without proof of legal and adequate access to the property for purposes of inspections by the Building Division. Other Permits. Multiple separate permits may be required: (1) State Electrical Permit, (2) County WS Permit, (3) another permit required for use on the property identified above, e.g. State or County Highway/ Road Access or a State Wastewater Discharge Permit. Vold Permit, A Building Permit becomes null and void if the work authorized is not commenced within 180 days of the date of issuance and if work is suspended or abandoned for a period of 180 days after commencement. CERTIFICATION 1 hereby certify that I have read this Application and that the information contained above is true and correct. I understand that the Building Division accepts the Application, along with the plans and specifications and other data submitted by me or on my behalf (submittals), based upon my certification as to accuracy. Assuming completeness of the submittals and approval of this Application, a Building Permit will be issued granting permission to me, as Owner, to construct the structure(s) and facilities detailed on the submittals reviewed by the Building Division. In consideration of the issuance of the Building Permit, I agree that 1 and my agents will comply with provisions of any federal, state or local law regulating the work and the Garfield County Building Code, ISDS regulations and applicable land use regulations (County Regulation(s)). I acknowledge that the Building Permit may be suspended or revoked, upon notice from the County, if the location, construction or use of the structures} and facility(ies), described above, are not in compliance with County Regulation(s) or any other applicable law. I hereby grant permission to the Building Division to enter the property, described above, to inspect the work. I further acknowledge that the issuance of the Building Permit does not prevent the Building Official from: (1) requiring the correction of errors in the submittals, if any, discovered after issuance; or (2) stopping construction or use of the structure(s) or facility(ies) If such is in violation of County Regulations) or any other applicable law. Review of this Application, including submittals, and inspections of the work by the Building Division do not constitute an acceptance of responsibility or liability by the County of errors, omissions or discrepancies. As the Owner, I acknowledge that responsibility for compliance with federal, state and local laws and County Regulations rest with me and my authorized agents, including without limitation my architect designer, engineer and/ or. builder. 1 1 hereby acknowledge that 1 have read and understand the Notice and Certification above as well as e p vided the required information which is correct and accurate to the best of my knowledge. Property Owner Print and Sign veckde— 5 5 Date OFFICIAL USE ONLY �Spedal Conditions: Adjusted Valuation: Plan Check Fee: Permit Fee: Manu home Fee: Misc Fees: Total Fees: (5+o. D Fees Paid: f od . DD Balance Due: P 92 _42; DF-alt" ISDS No: Setbacks: OCC Group: Const Type: Zoning: R BUILDING / PLANNING DIVISION : i 1 r 1 c Signed • pprovalf Dat I . #la? -6D, y# IIoG*/ 4 f 1215 T./MCC root Duro-Last over EPS filler and %" DensDeck Scope of Work Duro-Last Roofing Installation Overview We propose to install the complete 50 -mil, mechanically -attached prefabricated PVC Duro-Last single -ply roofing system using white colored membrane according to the manufacturer's requirements, local codes, and the following details: Preparation 1. The existing roof will remain in place and will be prepared to accept the installation of the new roofing system by removing debris, etc. 2. Deteriorated decking, if any, will be removed and replaced on the time & materials basis of $75 per hour, plus materials, which will not be marked up more than 15%. Deck Installation 1. A 1/4" DensDeck cover board will be installed directly under the roofing membrane, providing increased hail protection and a Class A fire rating. 2. The metal pans will be filled with EPS insulation. Perimeter, Walls, and Edges 1. The new membrane will run up and over the parapet walls and will be terminated on the outside edge with fascia bar and cover. 2. At the gutter areas, the membrane will terminate inside of the gutter without disturbing the gutter or water flow. 3. The roof edge will be terminated with 1-3/4" fascia bar and white cover. Details 1. All rooftop curbs and penetrations will be completed with custom prefabricated flashings. 2. Moisture relief vents will be installed about every 1,000 SF to effectively allow the roof to breathe. Scope of Work - Page 8 of 18