Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Plans
THIS INSIGNIA IS THE PROPERTY OF THE COLORADO ON OF HOUSING THIS NONRESIDENTIAL STRUCTURE COMPLIES WITH THE FACTORY BUI NONRESIDENTIAL STRUCTURE STANDARDS OF THE STATE OF COLORA MANUFACTURER(S)' NAME PLAN APPROVAL NO. UNIT ID# DATE BUILT CERTIFICATION NO. FBNR 1056,3 MANUFACTURER CERTIFIES THE FOLLOWIN CODES BUILT TO: ROOF DESIGEI LOAD WIND DESIGN It6F.tESSURE FLOOR DESIGN LOAD---_., FIRE RATING EXTERIOR WALLS FIRE RATING FLOOR FIRE RATING CEILING PSF PSF PSF HR 10125/2012 FLOORPLAN ECTRICAL PLAN �1 FRAME I -BEAM: ..,,. CROSS MEMBER:... HITCH: AXLES: TIRES: PAINT: MISCELLANEOUS:. BOOR BOTTOM BOARD:.. INSULATION:.... JOISTS: PERIMETER JOIST: DECKING: COVERING: EXULT YitaS STUDS:......,. BOTTOM PLATE: TOP PLATE: .... WALL HEIGHT: WALL COVERING: INSULATION: SHEATHING: SIDING: ....... SIDING COLOR: . TRIM:......... TRIM COLOR:... FRONT DESIGN: INTERIOR WALLS STUDS:........ BOTTOM PLATE: . TOP PLATE:.... WALL HEIGHT:.. WALL COVERING: REST ROOM COVERING: ROOF RAFTERS: SUB COLING PANEL: SUSPENDED PANEL: INSULATION:... SHEATHING:.... ROOFING: ROOF VENTS:... ROOF' VENTS:... TIE DOWNS: 12' JR. I BEAM ASTM A-36 STEEL (OUTRIGGER TYPE) 13 GAUGE ANGLE & ROD AT 48' 0.C. DETACH WITH 2-5/16' COUPLER & ELEVATING JACK TANDEM 60001 WITH ELECTRIC BRAKES 8:00 x 14.5 10 PLY MINIMUM 3 MIL BLACK ASPHALT N/A WOVEN PLASTIC VAPOR BARRIER TYPE BOTTOM BOARD R-11 (3 1/2") UNFACED FIBERGLASS 2X6I2SPF EQUAL OR BETTER 0 16' O.C. TRANSVERSE 2X6N2SPF EQUAL OR BETTER SINGLE 5/8' T&G STURD-I-FLOOR PLYWOOD W/16' 0.C. SPAN INDEX 1/8" VINYL 11LE 2X4 STUD GRADE SPF EQUAL OR BETTER 016' 0,C. SINGLE 2X4 1-3SPF EQUAL OR BETTER SINGLE 2X4 13SPF EQUAL OR BETTER 8'-4' ACTUAL HEIGHT 1/4' WISCONSIN BIRCH PANEUNG(CLASS 3 F.S.) R-11 (3 1/2') KRAFT BACKED FIBERGLASS N/A 7/16" T1-11 SMART PANEL W/GROOVES 4' 0/C COLONIAL WHITE I X 4 W000 TRIM BOARDS HERON BLUE SQUARE 2X4 STUD GRADE SPF EQUAL OR BETTER 0 16" 0.C. SINGLE 2X4 Jj3SPF EQUAL OR BETTER SINGLE 2X4 #3SPF EQUAL OR BETTER 8'-4'ACTUAL HEIGHT I/4" WISCONSIN BIRCH PANELING (CLASS 3 F.S.) 1/4" VINYL COVERED PANEUNG (CLASS 3 F.S.) WASHABLE SINGLE SLOPED TRUSSES 016' O.C., 50,E LIVE LOAD 13 1/2' HEEL 16 1/2" PEEK 138' LENGTH TRUSS 410011T0234 1/2" RAW GYPSUM (CLASS I F.S.) SUB HEIGHT B'-4" 2X4 T -GRID SUSPENDED FINISHED HEIGHT 7'-11' L= R-19 (6') KRAFT BACKED FIBERGLASS 3/8" OSB STRUCTURE WOOD W/ 16/0 SPAN INDEX 30 GAUGE GAIN. STEEL KOOL SEAL SEAMS (2) END VENTS (1) POWER ATTIC FAN TO OPERATE AT 60% RELATIVE HUMIDITY (4) OVER THE ROOF TYPE GENERAL NOTES THESE PLANS SHOULD NOT BE SCALED FOR DIMENSIONAL REFERENCE. ALL DIMENSION LINES AND NOTES SUPERCEDE ANY SUCH REFERENCES. C&B SHALL NOT RESPONSIBLE FOR LOCAL CODES OR PERMITS. ALL NOTES PERTAINING TO "IN FIELD, ON- SITE, OR BY BUILDER" SHALL. BE THE RESPONSIBILITY OF THE CONTRACTOR. PIM PACKAGE EXTERIOR DOOR INTERIOR DOORS WINDOW FURNRTURE DESK TOP: ...... SHELVES: PLAN TABLE: ...... PLAN RACK: ...... STANDARD TRIM W/ 6" COVE REST R0011 COLOR: BROWN (2) 36" X 80" INS/STEEL W/I0" SAFETY GLASS UTE, STAY CHAIN, WOOD JAMBS, DEAD BOLTS, LOCKSET,(KEYED ALIKE W/I:IASTER) LATCH GUARD, WEATHER STRIPPING & THRESHOLD (2) 36 X 80 PRE FINISHED HOLLOW CORE W/ 1-1/2 PAIR HINGES, FACTORY JAMBS, PASSAGE HANDLES & WALL BUMPER (1) 24 X 80 PRE FINISHED HOLLOW CORE W/ 1-1/2 PAIR HINGES, FACTORY JAMBS, PRIVACY HANDLES & WALL BUMPER (7) 46" X 27" MILL FINISHED ALUMINUM HORIZONTAL SLIDER. SINGLE GLASS, INSECT SCREEN, SECURITY SCREENS & BLINDS (2) 24" DEEP 3/4' THICK TOP MATERIAL W/(2) "FILE CABINET & (2) ACCESS HOLES CUT OUT TYPICAL EACH DESK (2) 12 DEEP WIRE OVERHEAD (1) 36X60 W/ FOLDING LEGS (1) STANDARD E F SERVICE: 120/240 VOLT SINGLE PHASE, 3 WIRE , 6011L. WITH GROUND LOAD CENTER: .. (1) 100 AMP 240 VOLT SINGLE PHASE MAIN PANEL ENTRANCE: ..... 1 1/2" EMT CONDUIT THROUGH FLOOR RACEWAY:...... MIN j 14 90 ' ROMEX W/ GROUND LIGHTS:(4)FOUR TUBE FLUORESCENT TROFFER DIFFUSED (RECESSED MOUNT) (2 75 WATT WEATHER PROOF INCANDESCENT EXTER1CR PORCH LIGHT (1) 100 CFM LIGHTED EXHAUST FAN W/ROOF CAP RECEPTACLES: .. (11) 125 VOLT 15 AMP IVORY DUPLEX GROUNDING TYPE (1) 125 VOLT 20 AMP IVORY DUPLEX GFI TYPE 1 125 VOLT 20 AMP BELOW FLOOR FOR HEAT TAPE SWITCHES: 6 120 VOLT IVORY TOGGLE TYPE 1 W/RED COVER FOR WATER HEATER DISCONNECT MISCELLANEOUS: -(2)J -BOX W/COVER & 1/2' CONDUIT STUB THRU FLOOR FOR PHONE BY OTHERS AT SITE 1) POWER ATTIC FAN TO OPERATE AT 60% RELATIVE HUMIDITY PLUMBING SUPPLY UNES: TYPE'L" COPPER WASTE UNES: PVC WATER HEATER:(1) 6 -GALLON 120 VOLT ELECTRIC WATER CLOSET:(1) WFIITE CHINA TANK TYPE W/1.6 GAL. FLUSH, STANDARD BOWL & OPEN SEAT LAVATORY:.., (I) WHITE OVAL IN FACTORY BASE CABINET & FAUCET ACCESSORIES (I) MIRROR (1) SOAP DISH & (1) UPGRADED T.P. HOLDER H.V.A.C. HEATING: ...... COOLING: DUCT:... DIFFUSERS: RETURN AIR:... RETURN AIR DUCT:... MISCELLANEOUS (1) 10 KW 240 VOLT ELECTRIC RESISTANCE HEAT STRIP (1) 30.000 8TU 240 VOLT SINGLE PHASE BARD AIR CONDITIONER 6' X 16' FIBERGLASS DUCT BOARD IN CEILING (5) 8"X8" WHITE ADJUSTABLE (1) 30X16 GRILLE AT UNIT WALL & (2) 12X12, (2) 8X8 CEILING GR 4' X 14" FIBERGLASS DUCT BOARD 114 CEILING / ALL MATERIALS ARE C&B CUSTOM MODULAR STANDARD UNLESS- OTHERIMSE NOTED ALL DOOR ADJUSTMENTS ARE ON SITE BY OTHERS C&B CUSTOM MODULAR IS NOT RESPONSIBLE FAR LOCAL C00 0 PERMITS INDEX PAGE DESCRIPTION 1 2 .3 4 5 6 EL SUSPENDED CEILING COVER BLOCKING 7 8 ELEVATION CROSS SECTION PLUMBING PLAN 5 Resun Leasing 1248 0 f fzce 11'-9" X 44'-0" ACTUAL SIZE BUILDING LOCATION. CO, KS, MO & UT APPROVED SUBJECT TO NOTED EXCEPTIONS $ INSPECTIONS GARFIELD COUNTY BUILD G EP, Date / / /513, LD COPY NO INSPECTION WI'T'HOUT THESE PLANS ON SITE Polite of kr_,554,;/;* ao 7 Xge i1i o, rr// .9770' -7c c, 1: //2/? 3. AP/4- refeem-orP fit. DESIGN CRITERIA; .-- OCCUPANCY GROUP "B" CONSTRUCTION TYPE V -N 517 SQUARE FEET OCCUPANT LOAD: 5 ROOF LIVE LOAD: 50 psf ROOF DEAD LOAD; 10 psi FLOOR UVE LOAD:50 psf FLOOR DEAD LOAD:. 7psf MND LOAD:.......80 MPH )MND EXPOSURE: "C" SEISMIC ZONE:.,.....'3' CONES' PER STATE ELECTRICAL CODE PER STATE BUILDING CODE PER STATE MECHANICAL CODE PER STATE PLUMBING CODE PER STATE ENERGY CODE Building Notes; The ,Job specIFIcc,tions supersede the detail specifications where there Is a conflict. Building to be located minimum 30' From existing property line. Buildings on the same property shall be assumed to have a property line between them, The building exterior and the facilities within the building shall be Identified with the International symbol of accessibility others) The dealer/owner shall be responslble for on site barrier free pravlsfons, Te.l s .:ps, ramps, parking signs, eta. Buliding approach Iwai cT-wciy or ram to be b' wIBe minimum and a gradient of not rore than 1' In 20'. Exit doors to remain openable during business hours from the Inside without the use of a key or any special knowledge. Corrosion resistant flashing at top and sides of doors, windows and at roof penetrations shall be provided. BUILDING ACCESSIBILITY PROVIDED BY OTHERS AT SITE BY MEANS OF RAMP ADEQUATE HANDICAP TOILET FACILITIES ARE LOCATED AT SITE WITHIN 500 FT. ANO CAPABLE OF WITHSTANLING THE INCREASED OCCUPANT LOAD. �i41S STRUCTURE IS I'JTENDE© FOR USE AS A TEMPORARY CONSTRUCTION FTriff OFfl NL ' THIS BUILDING NOT TO BE SITED WHERE ROOF LIVE LOADS EXCEED 50ft REVISIONS/DATE REV. PER 3rd PARTY L\ 1-8-01 BB C & B CUSTOM MODULAR 2224 BLOOMINGDALE DR. BRISTOL, INDIANA 46507 (219) 848-7300 SCALE: NONE DATE: ,PACE: 8-22-00 1 CHECKED BY: DRAWN BY: BB TITLE: RESUN LEASING 1248 OFFICE (11'-9" X 44'-0" ACTUAL) DISK #: SERIAL : DRAWING #: 001248FOC 11'-9' 1V-1 1/2' 3'-7 S/8' 3 3/4' 11' -LO 1/.' APPROVED BU 44'CTI 19'-1 3/4' 37/-4 3/4' 4' 31'-5 3/4' 6'-10 3/4' 6' 4' -1 24'-7' 17'-4 3/4' 4' 12' 11'-8 1/4' LOCATE STATE SEALS, 3RD PARTY SEALS e, DATA PLATE DN FACE OF ELECT. PANEL 3 3/4' --I- 4'-0 3/4' 24' DESK TEIP W/ (2) FILE CABINETS & (1) 12' 0,H, SHELF & (2) HOLES FOR ACCESS TYP EACH END DRAWING LEGEND 37'-4 3/4' SYMBOL QTY, r 1 =ix 1 120/240 VOLT ELECTRICAL PANEL 2 1 THERMOSTAT E 6 8 X 8 CIELING SUPPLY AIR DIFFUSER t 1 THRU WALL RETURN AIR GRILLE O 4 CEILING RETURN AIR GRILLE SIZE PER PRINT 24 3/4 X 81 3/4 r PLAN RACK ♦' 4 TIE DOWN STRAP LOCATION 2-2X4 #2SPF FLAT 1 WATER SUPPLY INLET LOCATION lib 1 DWV-MAIN DRAIN LOCATION Iw i POWER ATTIC EAN 7I PROVIDE SWITCH W/RED COVER FOR W.H, DISCONNECT 7 I J= T I 1-19111 I 04 on 1 120/240 VOLT ELECTRICAL PANEL HVAC - D 24 X 48 RECESSED FLUOR. LIGHT W/DIFFUSER #6 2 EXTERIOR ]NCANDESCANT LIGHT E 11 r (Irl 8 120 V. DUPLEX GFI RECEPT $ 7 120 V. SWITCH 5 0 :LA.0 2 J -BOX W/CONDUIT STUB THRU FLOOR & COVER O 2'-6 7/8' 3 100 AMP 3 120 V. BELOW FLOOR HEAT TAPE RECEPT 6 1 100 CFM CEILING EXHAUST FAN W/LIGHT 20 AMP CK#63 WATER V-7' ATTIC FAN 1 15 AMP 014 HEATER 1,--11, 1'10 1/8' I i ^� I I •2 4 -0 1/4' 2' 0 3/8' 2=� 2 • t O 4`-7' SS, 4 \ 3 4`-6 1/2' 1I rr r T I t 100 AMP 120/240 VOLT SINGLE PHASE 60 HZ. MAIN PANEL W/100 AMP 2 -POLE MAIN BREAKER #8 BARE CU. GRND, WIRE W/CONNECTION TO METAL UNDERGROUND WATER PIPING SYSTEM AND A SUPPLEMENTAL ELECTRODE. (PROVIDED & INSTALLED BY OTHERS AT SITE) 100 AMP MAIN PANEL 1-1/2' EMT CONDUIT W/3 43 CU THW SERVICE ENT. WIRE BY OTHERS AT SITE RISER DIAGRAM DRAWING LEGEND SYMBOL QTY. DESCRIPTION on 1 120/240 VOLT ELECTRICAL PANEL HVAC 4 24 X 48 RECESSED FLUOR. LIGHT W/DIFFUSER #6 2 EXTERIOR ]NCANDESCANT LIGHT 1 11 120 V. DUPLEX (Irl 1 120 V. DUPLEX GFI RECEPT $ 7 120 V. SWITCH AC 2 J -BOX W/CONDUIT STUB THRU FLOOR & COVER O 1 THERMOSTAT OMT 1 120 V. BELOW FLOOR HEAT TAPE RECEPT 6 1 100 CFM CEILING EXHAUST FAN W/LIGHT ELECTRICAL PANEL SCHEDULE CK T. ID # ITEM POLES BREAKER WIRE 1 HVAC 2 60 AMP #6 2 LIGHTS 1 15 AMP #14 3 RECEPTS 1 15 AMP #14 4 RECEPTS 1 15 AMP #14 5 GFI/HEAT TAPE 1 20 AMP #12 6 WATER HEATER 1 20 AMP #12 7 ATTIC FAN 1 15 AMP 014 ELECTRICAL NOTES 1. ALL RECEPTACLES TO BE GROUNDING TYPE, 2, ALL WIRING TO BE PER THE CURRENT CODE IN EFFECT. 3. MAIN PANEL TO BE MARKED 'SUITABLE FOR USE AS SERVICE EQUIPMENT' AND BE EQUIPPED WITH BREAKER/FUSE TYPE OVERCURRENT PROTECTION. 4. PROPER THERMAL OVERLOAD PROTECTION TO BE PROVIDED FOR ALL MOTORS. 5. DISCONNECTING MEANS WITHIN SIGHT REQUIRED FOR ALL MOTORS. 6. WEATHER PROOF PROTECTION REQUIRED FOR ALL OUTDOOR LIGHTS, RECEPTACLES, AND DISCONNECTS. 7. PROPER WORKING CLEARANCES TO BE PROVIDED AND MAINTAINED ABOUT ALL ELECTRICAL EQUIPMENT. 8. ALL FLUORESCENT FIXTURES REQUIRE THERMAL PROTECTION AND PROPER CLEARANCES FROM INSULATION ALSO APPLICABLE FOR INCANDESCENT FIXTURES. 9. COMBINATION EXHAUST FAN/LIGHT AND ALL RECESSED INCANDESCENT FIXTURES TO BE THERMAL PROTECTION, 10. EXIT LIGHTS 'IF ELECTRIC' MUST BE FED FROM AND APPROVED EMERGENCY SERVICE CONNECTED AHEAD OF BUT NOT WITHIN MAIN SERVICE DISCONNECTING MEANS ENCLOSURE AND INSTALLED AS PER SERVICE REQUIREMENTS OR BE BATTERY BACKUP TYPE UNITS, 11. ALL EXTERIOR METAL TO BE GROUNDED PER N.E.C. EEETRICAE PEA\ REVISIONS/DATE C & B CUSTOM MODULAR 2224 BLOOMINGDALE DR. BRISTOL, INDIANA 46507 (219) 848-7300 SCALE: 1 /4"=1 -0" DATE: 8--22-00 PAGE: 3 DRAWN BY: Be CHECKED BY: TITLE: RESUN LEASING 1248 OFFICE (11' -9" X 44'-0" ACTUAL) DISK #: SERIAL #: DRAWING #: C01248F0-E O'-6 3/4' 0'-6 3/4' 11 .11 1/4' --1 rm- 01-3 1- 1'-6 7/8' -17 T 1'-40 1/8' r-10 1/8' r -mill [ 0 1 - - -,. - 1 1.1) I i I .._ .../' Ilimp. O'-'3' I I I I I 7 T T T -1 I1 1 • I L_.---- _ • 0o. 1- X 0 -1 r X t X / h X X • -n = = -2t-r I -1- -I 1 L ___I 1 J I I 11-11 I -P-1 I I I 1 I 1/4' — I- 01-6 3/4' -I 4 12— -0 me mmOMmiwo 11111.111 11•111111111MINIMPIMII 11111.11.1111.111 1'-6 7/8' SUSPE\ 11-10 1/8' rN ILI G 11) 1 01-6 3/4' -I L-- .DLAN REVISIONS/DATE REV. PER 3rd PARTY 1-8-01 BB C & B CUSTOM MODULAR 2224 BLOOMINGDALE DR. BRISTOL, INDIANA 46507 (219) 848-7300 SCALE: 1 /4"=1 -0" DATE: 8-22-00 PAGE: 4 DRAWN BY: BB CHECKED BY: TITLE: RESUN LEASING 1248 OFFICE (11-9" X 44-0" ACTUAL) DISK #: SERIAL #: DRAWING #: C01248F0-S HITCH END ELEVATI❑N 1 REAR ELEVATI❑N CURB SIDE ELEVATI❑N t READ SIDE ELEVATI❑N REVISIONS/DATE C & 8 CUSTOM MODULAR 2224 BLOOMINGDALE DR. BRISTOL, INDIANA 46507 (219) 848-7300 SCALE: 3/1 6"=1 -0" DATE: 8-24--00 PAGE: 6 DRAWN BY: BB CHECKED BY: TITLE: RESUN LEASING 1248 OFFICE (i1'-9" X 44'----0") DISK #: SERIAL #: DRAWING #: C01 248F0V R-19 (6") FIBERGLASS INSUL.. W/ KRAFT FACING 1/4 WOOD TRIM BOARD (TYP) PROVIDE S❑LID WOOD BLOCKING @ i1 �N"AAY�lylri� :iNf {Yl"4�rl+iriri+4+AYArArlri�A+AY ir4r�__ rrrr If r W - 1},1f ♦.. . � �____1�/11A111�1 � Alll1A14+i11 Ei..!+AA 1►'.::. SUSPENDED CEILING HEIGHT (TYP) 16" X 6" FIBERGLASS SUPPLY AIR DUCT 1/4" BIRCH (CLASS 3 F.S.) TYP. INTERIOR FINISH R-11 (3 1/2") FIBERGLASS INSUL. W/ KRAFT FACING R-11 (3 1/2") FIBERGLASS INSUL. WOVEN PLASTIC BOTTOM BOARD VAPOR BARRIER 13 GAUGE ANGLE & ROD CROSS MEMBER @ 48" O.C. CEILING HEIGHT m 1:1.+d.+ddA. OIfo+j+A*A+j+1+A+1+4+jr*+I+I+I'M+A+."AIA1lA41A+11AlIrAAA1AfArAr/rArM 1. TRUSSES SHALL BE CERNIE0 IOR THE LOADS AND APPuCATWON USED. 2. TRUSSES SHALL BE PLACED 01RECILY OvER MOS MIDI A 51 NGLE SHG1E 10P PLATE 0 SENO USED. 3. !N1ERAI PAR af11OHs 10 bC CONsTRVCrE0 TO wTTH5TNIO A S PSr 4 3R00NTM. FORCE. 4. I1TER:04 YGU . WARD 514LLL BE L/4' NOW 0HAL THICKNESS OR CONFORM 10 SECTION 922 (ltsrm watt WATER IAS SUSPENDED FROM NON-OCMBUST24J 4 101). S. ALL L1iaER T4 eE GRAM) Nt0 MVdEO. a Co1PRASHDet PLATED REIN MO TO ENSURE N000 TO W000 CONTACT AT BEAR 140 WALL 10 ROOF 2ONT0. 7. 0•D00 MO NOTCH NC NOT To OCCUR 1N THE COMER 1/3 OF LENGTH OF WALL STUDS. E. 05113008 BF0ACIHC 105 BE PROVIDED W11)1 1L -LS WOOD saw 711x' FOREWORD SE0140. 'STUMPAGE' 051000OR 5HEA114NG OR 3/b' COX P000 000 0/100104100 GLUES. 9. 1fNRLAT5044 SYSTEM SHALL BE A MECHANICAL EN Misr AND SUPPLY 001 5YST0.L THE ExHAuST RATE SHALL SE 0.02 CFN PER SOFT. OF H OR40HTAL AREA THE 1,,ENERAT1N SYSTEM 5FLy1 OPERATE MIEN THE R0ATNE mune( EXCEEDS 60X 114 THE SPATE. SAEWALL (TTP.) 1+l+l itlf4�{�A+A+I+/+/r11+/+4+Ar1/1r4+111/lW{+A+/+ArA+1+A+1+ 6 ARE INF TYDICAL CR SS SE:TI TRUSSES siva. BE PEALED ONEC11.Y OrEli STUDS WHEN A 2010E 5110..E TOP PLATE IS ODM USED. SIDEWALL TO INTERIOR PARTITION 01TER1OR PARI111011 Ri7EPX,R(1011.) P44111 ON (OMP.) INTER0 PARDON MP.) S X A' 30 Go STA* (3) PER wpm cow . w/ (6) A-0 !OILS OR 00104H.wr. INTERIOR PARTITION TO INTERIOR PARTITION StDEYWU (TYP.) SIDEWALL TO ENDWALL SINGLE TOP PLATE BEARING WALL DETAILS SCALE: 30 GAUGE GALV, STEEL 3/8" OSB ROOF SHEATHING 0/16 SPAN INDEX TRUSS PER SPECS 2X4 143 SPF ROOF RAIL (TYP.) 2X4 # 3 SPF SINGLE TOP PLATE 1/2" RAW GYPSUM CEILING BOARD (CLASS 1 F.S.) 2X4 T—BAR GRID SUSPENDED CEILING 14" X 4" FIBERGLASS RETURN AIR DUCT 7/16" T1--11 SMART PANEL W/GROOVE 4"0/C 2X4 STUD GRADE SPF STUDS @ 16" O.C. 5/8" T & G PLYWOOD FLOOR DECKING W/ 16" 0.0. MAX SPAN 2X6 #2 SPF TRANSVERSE FLOOR JOISTS @ 16" D.C. (TYP.) 2X4 #3 SPF BOTTOM PLATE 2X6 #2 SPF EDGE RAIL (TYP.) 13 GAUGE FORMED STEEL OUTRIGGERS @ 48" D.C. 12" JR. 1—BEAM MAIN FRAME MEMBERS REVISIONS/DATE C & B CUSTOM MODULAR 2224 BLOOMINGDALE DR. BRISTOL, INDIANA 46507 (219) 848-7300 SCALE: 3/8"=1 — 0" DATE: 8-29-007 PAGE: DRAWN BY: BB CHECKED BY: TITLE' RESUN LEASING 1248 OFFICE (111-9" X 441-0") APPROVED MODEL SERIAL #: 'DRAWING #: C0 1 248F0 ---X FIXTURE TR�� SITES MAX. TRAP TO VENT DISTANCE WATER' CLOSET - 3' TRAP ARM LAVATORY - 1-1/4' P -TRAP DRINK. FOUNT, - 1-I/4' P -TRAP 1 1/4' - 3.5' 1 1/2' - 5' 2' - 6' 3' TRAP (W/C) - 10' TYPICAL STUB THRU FLOOR LOCATION DWV DIPING PLAN TYPICAL STUB THRU WALL LOCATION J 3' 1 3' VTR WC 1-1/2' LAV 3' VTR 1-1/2' TO 4' MAIN BUILDING DRAIN BWV 1, DWV MATERIAL TO BE. PVC 2, ALL PIPES TO BE SECURED AT 4' O,C. 3. ALL CLEAN OUTS SHALL BE ACCESSIBLE, CLEAN CUTS PROVIDED AT THE BASE OF ALL SOIL STACKS, NO PROVIDED SO THAT ALL HORIZONTAL PIPING CAN BE REACHED WITH A CLEANOUT TOOL WITHOUT PASSING THRU MORE THAN 45 DEGREES OF TURNS. 4. 1/4' FT. SLOPE PROVIDED ON ALL HORIZONTAL BRANCHES. 5. VENTS SHALL BE 3' DIAMETER, 12' ABOVE AND BELOW ROOF AND SHALL NOT BE LOCATED WITHIN 10' OF OTHER VENT OPENINGS, 6. ALL VERTICAL TO HORIZONTAL OR HORIZONTAL TO HORIZONTAL CHANGE OF DIRECTION SHALL BE THRU A LONG TURN T,Y. OR COMBINATION WYE WITH 1/8' BEND, 7. ALL HORIZONTAL TO VERTICAL CHANGE OF DIRECTIONS SHALL BE THROUGH A SANITARY TEE, OR IF AT THE SAME LEVEL ON VERTICAL STACK, THROUGH AN APPROVED DOUBLE FIXTURE FITTING, - - VENT PIPING WASTE PIPING C&B CUSTOM MODULAR SHALL PROVIDE STUBS THROUGH FLOOR P -TRAPS AND VENTING FOR DWV PIPING AND CONNECT AS MUCH PIPING UNDER FLOOR THAT IS POSSIBLE, SOME PIPING MAY BE LEFT OFF TO ALLOW SHIPMENT OF THE UNIT, 1-1/2' 1-1/2' C.O. AIR CHAMBER PER WATER SUPPLY NOTES WC 1/2' 6 -GAL WATER HTR 1/ 1/2' LAV 1/2 3/4' 1/2' 3/4' INLET T&P VALVE TO DRAIN THRU FLOOR (TYP. 2) DI -ELECTRIC UNIONS TYPICAL AT ALL WATER HEATER CONNECTIONS WTR. HTR. S.O. VALVE MAIN GATE VALVE WATE PIPING PLAN WATER SUPPLY NOTES 1. WATER SUPPLY LINES TO BE= TYPE 'L' COPPER AND CPVC 2. COPPER OR GALVANIZED WATER PIPING TO BE SUPPORTED AT 4' O.C. POLYBUTLENE AT 3' O.C. 3. WATER TEMPERATURE FACTORY SET AT 120 DEGREES F., CONTROLS LOCATED BEHIND COVER PANEL. 4. A SHUT OFF VALVE SHALL BE REQUIRED FOR EACH FIXTURE. 5. WATER HAMER ARRESTORES PROVIDED, OR IF AIR CHAMBERS, TO BE MIN, 15' LONG AND NOT LESS THAN THE DIA, OF PIPE SERVED. 6. WATER HEATER EQUIPPED WITH DRAIN COCK, 7. DIELECTRIC UNIONS TO BE USED AT CONNECTIONS OF WATER LINES TO WATER HEATER, 8, COLD WATER INLET TO BE PROVIDED WITH A SHUT OFF VALVE ABOVE FLOOR AT THE WATER HEATER, 9, T & P VALVE, 210 DEGREES F., 125 PSI, WITH A 3/4' DISCHARGE PIPE TO THE EXTERIOR VIA A 4' AIR GAP. 10. FULL SIZE SHUT OFF VALVE TO BE PROVIDED BETWEEN THE BUILDING AND WATER MAIN (METER). Il. L/2' WATER SUPPLY SHALL SUPPLY ONLY ONE FIXTURE, INDIVIDUAL FIXTURE SUPPLY 1/2' UNLESS NOTED. ALL WATER SUPPLY LINES TO BE. CPVC HOT WATER LINE COLD WATER LINE REVISIONS/DATE C & B CUSTOM MODULAR 2224 BLOOMINGDALE DR. BRISTOL, INDIANA 46507 (219) 848-7300 SCALE: NONE DATE: 8-29-00 8 PAGE: DRAWN BY: BB CHECKED BY: TITLE: RESUN LEASING 1248 OFFICE (11'-9" X 44'-0") APPROVED MODEL SERIAL #: DRAWING #: CO 1248F0 ---P STEEL PIER INSTALLED PER MANUFACTURER'S INSTALLATION INSTRUCTIONS 16' X18- ABS PIER PAD BY 11E -DOW ENGINEERING (PART 159300) GRADE OUTRIGGER LENGTH LENGTH OF UNIT SEE PIER SPACING CHART SEE PIER SPACING CHART SEE PIER SPACING CHART SEE PIER SPACING CHART SEE PIER SPACING CHART SEE PIER SPACING CHART SEE PIER SPACING CHART r SEE TIE -DOWN DETAIL AT MAIN I -BEAM MODULAR BUILDING 3150 LBS 71E DOWN STRAP AT I -BEAM MINUTE MAN ANCHOR MODEL 36XDH CROSS DRIVE ANCHOR W/ MMA -S02 STABILIZER PLATE (OR EQUAL) INSTALLED PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. TYPICAL PIER DETAIL - MAX. LOAD 6.OK N.T.S. ABS PAD NOTES: 1, CLEAR ALL VEGETATION AND DEBRIS FROM THE AREA WHERE THE ABS PADS ARE TO BE PLACED 2. GROUND UNDER ABS PADS MUST BE LEVELED AND EVENLY COMPACTED. RACE ABS PAD M1TH GRID SIDE UP, SMOOTH SIDE DOWN. 3. CENTER BLOCKS ON ABS PAO AND COMPLETE PIER. FOUNDATION 1. FOUNDATION REVIEW AND INSPECTION IS TO BE PERFORMED BY THE LOCAL OFFICIAL HAVING JURISDICTION. 2. CRAWL SPACE TO BE VENTILATED AT 1 SO. FT. PER EACH 150 SQ. FT. OF CRAWL SPACE AREA TO BE VENTILATED. 3. PROVIDE POSITIVE DRAINAGE UNDER UNIT. 4. PROVIDE MINIMUM CRAWL SPACE ACCESS OF 22" x 24". 5. PIER LOADS ARE SHOWN IN KIPS 6. PER 2006 INTERNATIONAL BUILDING CODE - SEE 11E -DOWN SPACING CHART 7. UNIT MAY BE SHIMMED AS NECCESSARY WITH HARDWOOD SHIMS BETWEEN TOP OF PIER AND MODULAR UNIT FRAME S. 3000 PSF ASSUMED SOIL BEARING CAPACITY. 9, GROUND ANCHORS ARE TO BE CERTIFIED FOR A MINIMUM LOAD CAPACITY OF 4,725 POUNDS. THE ANCHORS SHALL BE LISTED FOR THE APPROPRIATE SOIL CLASSIFICATION ENCOUNTERED AT THE SITE. FOUNDATION LEGEND INDICATES BLOCKING TO BOTTOM OF MAIN I -BEAM )-- MAIN 1 -BEAM PERIMETER OF BUILDING 5.3K 5.3K SEE TIE -DOWN DETAIL AT MAIN I -BEAM ATTACH TIE -DOWN STRAP TO MAIN I -BEAM WITH TIE DOWN ENGINEERING GATOR BEAM CLAMP #59011 OR EQUAL 3150 LBS TIE DOWN STRAP AT I -BEAM MINUTE MAN ANCHOR MODEL 36X0# CROSS DRIVE ANCHOR W/ MMA-SD2 STABILIZER PLATE (OR EQUAL) INSTALLED PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. SEE TIE-DOMN SPACING CHART MAX. 3'-0' TIE -DOWN DETAIL AT MAIN I -SEAM N.T.S. INDICATES MINUTE -MAN OR EQUAL FRAME 11E -DOWN LOCATION AND DIRECTION DESIGN LOADS FLOOR LIVE LOAD FLOOR DEAD LOAD ROOF LIVE LOAD ROOF DEAD LOAD EXTERIOR WALL DEAD LOAD = 50 PSF = 10 PSF = SEE PIER SPACING CHART = 10 PSF = 42 PLF PIER SPACING CHART TIE -DOWN ENGINEERING PAD SIZE & PART NUMBER 30 PSF ROOF LIVE LOAD 40 PSF ROOF LIVE LOAD 16" X 18" PART #59300 B"-9" 8'-0" TIE -DOWN SPACING CHART WIND SPEED ANCHOR 90 MPH EXP C 100 MPH EXP C 110 MPH EXP C 120 MPH EXP C MINUTE MAN ANCHOR MODEL 3bXI)11 CROSS DRIVE ANCHOR 1S-0" MAXIMUM SPACING 12"-6" MAXIMUM SPACING MAXIMUM SPACING 7'-4" MAXIMUM SPACING TER • • .1 1111W. ' s/© 'AL 1—• � 1. J1illii1N\1ti fl M m 4 0 t 0 0 0. F z z