Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Application- Permit
Garfield County Building & Sanitation Department 108 8th Street, Suite #201 Glenwood Springs, Co. 81 601 Office- 945-8212 Inspection Line- 384-5003 Job Address Nature of Work Use of Building Owner Building Permit NO. pt4_5349 U&'c4,&2 R: 089 (- 333 - - 00 tiO4.4,k.-1 Contractor 6)4 '\.• Amount of Permit $ i 0 Date Clerk i cy cT S 11 OC ri° GARFIELD COUNTY BUILDING PERMIT APPLICATION 108 81h Street, Suite 201, Glenwood Springs, CO 81601 Phone: 970-945-8212 / Fax: 970-384-34701 Inspection Line: 970-384-5003 Parcel/Schedule No: [ 3 91.3 3 3 _ 00 f 00 AGREEMENT PERMISSION IS HEREBY GRANTED TO THE APPLICANT AS OWNER, CONTRACTOR AND/OR THE AGENT OF TIIE CONTRACTOR OR OWNER TO CONSTRUCT THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT. IN CONSIDERATION OF THE ISSSUANCE OF THIS PERMIT, THE SIGNER. HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND USE REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN IN 30.28.201 CRS AS AMENDED. THE SIGNER FURTHER AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPILED WITH IN THE LCOATION, ERECTION, CONSTRUCTION, AND USE OF THE ABOVE DESCRIBED STRUCTURE, THE PERMIT MAY BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT SHALL BECOME NULL AND VOID. THE ISSUANCE OF A PERMT BASED UPON PLANS, SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING BUILDING OPERATION BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF THS CODE OR ANY OTHER ORDINANCE OR REGULATION OF THIS JURISDICTION. THE REVIEW OF SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABLITIES BY GARFIEID COUNTY FOR ERRORS, OMISSIONS OR DISCREPENCIES. TIIE RESPONSIBILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICIALLY WITH THE ARTICTECT, DESIGNER, BUILDER, AND OWNER. COMMENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS INTEREST. Garfom.003. I HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE (INITIAL): 3 (110 Job Address: / d i q t / �4h ari f 7 " t�, 404 i LCL O ?) c C� l Lot No: l✓ l 7i�/vi 1L.IV& r ` ,. Ad ocic 0 3 _ —7 � � i7� c� cess - 010. PD 1,4' l' iII2 53 ] S bd. / Exemption: i L ilii &ors 1" p gm 0--f3ys. i 3 Wk Ph: (97� /= ‘/P dF73 2 = Owner: CO -14 d . aOn 3 Contractor: ,. GMe L- r i 1110/4 f//S Address: P, jf h: Lic. No. 4 Architect/Eng' er: .,, r ,Ar/ Lit let tOgihe'r Address: ;707b 40 1y W/rPh: -i I Eh/lie/am a m $nlr2 Lic. No. 5 J Sq. F . o Building: MI� Ft. of Lot: Heig�ht: No. of Floors: 6 Use of Building: Ua( 7, ` 7 Desetj e Work: V thc1nse — FiLL- »'i t Ml0r) e-xis-iiCarr 8 Class of Work: o New o Alteration o Remove Addition o Move 9 10 Garage: r- n j Single . I F i I` - o Double Carport: ❑ Single o Double ❑ Driveway Pe mit o On -Site Sewage Disposal o Site Plan (Septic) 11 'Valuation of Work: $ Adjusted Valuations: 12 Special Conditions: NOTICE A SEPARATE ELECTRICAL PERMIT IS REQUIRED AND MUST BE ISSUED BY THE STATE OF COLORADO. THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED D IS NOT IS UED WITHIN A0 DAYS, OR, ED IF CONSTRUCTION OR WORK 1S SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALLec PROVISIONS OF LAWS GOVERNING THIS TYPE OF WORK WILL BE COMPLETED WITHIN WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF C rN§T ° STI e > 4,7- _,------ ,— —,., ---f., ,,...,11-7-' Plan Check Fee: 6+'// Permit Fee: 6 3.25— Total Fee: Dated Permit Issued: �. h 1 OCC Group: Const. Type: �( Zoning: Setbacks: Manu. Home: ISDS No. & Fee: lk10r Fkc, 3 .2,6—Nv1--- 1 a.,10I�PT. APPROVAL ATTIJREr i JE r PP 1,1 `/ ..,, "I"allliW G. !DAT . P G , pTk r 0! !ATE AGREEMENT PERMISSION IS HEREBY GRANTED TO THE APPLICANT AS OWNER, CONTRACTOR AND/OR THE AGENT OF TIIE CONTRACTOR OR OWNER TO CONSTRUCT THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT. IN CONSIDERATION OF THE ISSSUANCE OF THIS PERMIT, THE SIGNER. HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND USE REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN IN 30.28.201 CRS AS AMENDED. THE SIGNER FURTHER AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPILED WITH IN THE LCOATION, ERECTION, CONSTRUCTION, AND USE OF THE ABOVE DESCRIBED STRUCTURE, THE PERMIT MAY BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT SHALL BECOME NULL AND VOID. THE ISSUANCE OF A PERMT BASED UPON PLANS, SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING BUILDING OPERATION BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF THS CODE OR ANY OTHER ORDINANCE OR REGULATION OF THIS JURISDICTION. THE REVIEW OF SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABLITIES BY GARFIEID COUNTY FOR ERRORS, OMISSIONS OR DISCREPENCIES. TIIE RESPONSIBILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICIALLY WITH THE ARTICTECT, DESIGNER, BUILDER, AND OWNER. COMMENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS INTEREST. Garfom.003. I HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE (INITIAL): 3 (110 GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS For SINGLE FAMILY DWELLING CONSTRUCTION Including NEW CONSTRUCTION ADDITIONS ALTERATIONS And MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. When reviewing a plan and it's discovered that required information has not been provided by the applicant, this will result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor shall be required to provide this information before the plan review can proceed. Other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. Any project with more than ten (10) occupants requires the plans to be sealed by a Colorado Registered Design Professional. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following checklist prior to and during design. Applicants are required to indicate appropriately and to submit the completed checklist at time of application for a permit. Plans to be included for a Building Permit, must be on drafting paper at least 18"x24" and drawn to scale. 1 Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks, balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line and original grade. A section showing in detail, from the bottom of the footing to the top of the roof, including re -bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house -rap, (which is required), siding or any approved building material. Engineered foundations may be required. A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. wind speed, wind exposure B or C, and a 36 inch frost depth. All sheets to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be incompliance with the 2003 IRC. l . Is a site plan included that identifies the location of the proposed structure or addition and distances to the property lines from each corner of the proposed structure(s) prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Properties with slopes of 30% or greater must be shown on the site plan. (NOTE Section: 106.2) Any site plan for the placement of any portion of a structure within 50 ft. of a property line and not within a previously surveyed building envelope on a subdivision final plat shall be prepared by a licensed surveyor and have the surveyor's signature and professional stamp on the drawing. Any structure to be built within a building envelope of a lot shown on a recorded subdivision plat shall include a copy of the building envelope as it is shown on the final plat with the proposed structure located within the envelope. Yes \' 2. Does the site plan also include any other buildings on the property, setback easements and utility easements? Please refer to Section 5.05.03 in the Garfield County Zoning Resolution if the property you are applying for a building permit on is located on a corner lot. Special setbacks do apply. Yes 3. Does the site plan include when applicable the location of the I.S.D.S. (Individual Sewage Disposal System) and the distances to the property lines, wells (on subject property and adjacent properties), streams or water courses? Yes ,A 2 4. Does the site plan indicate the location and direction of the County or private road accessing the property? Yes 5. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the IRC or per stamped engineered design? Yes toy. 6. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces . s the clearances required between wood and earth? Yes Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces and soffits? Yes 8. Do the plans include design loads as required by Garfield County for roof snow loads,. (a minimum of 40 pounds per square foot up to & including 7,000 feet above sea level), floor loads and wind loads? Yes ih.- '_.46 9. Does the plan include a building section drawing indicating foundation, wall, floor, and roof construction? Yes 10. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or joists or trusses? Yes 11. Does the building section drawing or other detail include the method of positive connection of all columns and beams? Yes 12. Does the plan indicate the height of the building or proposed addition from the highest point of the building or addition measured at mid span between the ridge and the eave down to existing (undisturbed) grade contours? Yes 13. Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase II certifications or phase II EPA certification? Yes No 3 14. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the IRC? Yes No 15. Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements comply with the requirements of the IRC? Yes No ii .- 16. Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable rooms? Yes No Ar 17. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety glazing for these areas? Yes No 18. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? Yes No 19. Do you understand that if you are building on a parcel of land created by the exemption process or the subdivision process, are building plans in compliance with all plat notes and/or covenants? Yes �l No 20. Do you understand that if you belong to a homeowners association, it is your responsibility to obtain written permission from the association, if required by that association, prior to submitting an application for a building permit? The building permit application will not be accepted without it. Yes No 21. Will this be the only residential structure on the parcel? Yes No If no -Explain: 22. Have two (2) complete sets of construction drawings been submitted with the application? Yes 23. Do you understand that the minimum dimension.a home can be on a lot is 20ft.wide and 20ft. long? Yes No 4 24. Have you designed or had this plan designed while considering building and other construction code requirements? Yes No 25. Do your plans comply with all zoning rules and regulations in the County related to your properties zone district? Yes No 26. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by the Garfield County Building Department? Yes No 27.. Do you understand that approval for design and/or construction changes are required prior to the application of these changes? Yes •F. No 28. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application submittal and that you will be required to pay the "Permit Fee" as well as any "Road Impact" or "Septic System" fees required, at the time you pick up your building permit? Yes R,L_ No 29. Are you aware that you must call in for an inspection by 3:30 the business day before the requested inspection in order to receive it the following business day? Inspections will be made from 7:30 a.m. to 3:30 p.m. Monday through Friday. Inspections are to be called in to 384-5003. Yes No 30. Are you aware that requesting inspections on work that is not ready or not accessible will result in a $47.00 re -inspection fee? Yes No 31,. Are you aware that you are required to call for all inspections required under the IRC including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of the building? Yes No 32. Are you aware that the Permit Application must be signed by the Owner or a written authority being given for an Agent and that the party responsible for the project must comply with the TRC? Yes ,(, No 5 33. Are you aware that prior to submittal of a building permit application you are required to show proof of a driveway access permit or obtain a statement from the Garfield County Road & Bridge Department stating one is not necessary? You can contact the Road & Bridge Department at 625-8601. Yes No 34. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups, unless you as the homeowner are performing the work? The license number of the person performing the work will be required at time of applicable inspection. Yes No 35. Are you aware, that on the front of the Building Permit Application you will need to fill in the Parcel/Schedule Number for the lot you are applying for this permit on prior to submittal of a building permit application? Your attention in this is appreciated. Yes No 36. Do you know that the local fire district may require you to submit plans for their review of fire safety issues? Yes No (please check with the building department about this requirement) T hereby acknowledge that ll have read, understand and answered these questions to the best i f my, ability. Signature of Owner (C`7 ( '.2,V3 Phone: Project Name: (days); et 3,clext Date 3-40 —9 18 3' (evenings) Project Address: ( 769 L( (Ay 62 Notes: If you have answered "No" on any of the questions, you may be required to provide this information at the request of the Building Official prior to beginning the plan review process. Delays in issuing the permit are to be expected. Work may not proceed without the issuance of a permit. If it is determined by the Building Official that additional information is necessary to review the application and plans to determine minimum compliance with the adopted codes, the application may be placed behind more recent applications for building peiunits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review, delay in issuance of the permit or delay in proceeding with construction. BpminregOct2004 6 GARFIELD COUNTY BUILDING REQUIREMENTS Codes: 2003 IRC, IBC, IFGC,. IMC, IPC,. Setbacks: Check subdivisions and zone district for setback requirements. Snovvload: 40PSF up to 7000ft. elevation. 50PSF 7001 to 8000ft. 75PSF 8001 to 9000ft. 100PSF 9001 to 10000ft. Seismic design category: 13 Weathering probability for concrete: Severe Termite infestation probability: None to slight Wind speed: 90mph Decay probability: None to slight Wind Exposure: 13 or C (see section R301.2.1.4) Frost Depth: 36in. to 8000ft. elevation. 42in. 8001 and above. Winter Design Temperature: Minus 2 to 7000ft.; minus 16 over 7000ft. elevation. Air Freezing Index: 2500deg F -days to 7000ft.; over 7000ft. to be determined by Building Official. Ice shield under-layment required. Mean Annual temp.: Variable Insulation: Maximum glazing U factor: 0.50 Minimum R -Values: Ceilings/roofs R values are: R-30 stick built structures. R-38 log construction and steel rafter construction. ■ Walls R values are R-19 wood frame; R-19 cavity R-3 sheathing steel studs. • Floors R -values are R-19. ci No. ."' Job Address r i ~et ,dh-xi.A/pLe.„11 Contractor Z:‘,--110\A-C4-/'--- Owner \'1..'--- Owner Assessor's Parcel No Date S/ / f BUILDING PERMIT CARD iwzu (cc si e,)-3 Setbacks: Front Soils Test Footing M:.AI,-9.:m:., Foundation Address G` , 1 . 11 C 6t'Phone # `Vie -.5"9Y~ (?34 Address ° w' -k 0.4 Phone # /R-:.,z,'i3 Rear RH LH Zoning Grout Underground Plumbing Rough Plumbing Framing insulation Roofing Drywall Gas Piping INSPECTIONS Weatherproofing 011) Mechanical Electrical Rough (State) Electric[ Final (State) 10 /Checklist Completed? Certificate Occupancy # Date Septic System # iy1 Date Final NOTES Agyfrct Other (continue on back) COUNTY OF GARFIELD - BUILDING DEPARTMENT 108 8th St, Suite 201 Glenwood Springs, Colorado Phone (970) 9458212 Job located at 71v g?2, Permit No. qiir, have this day inspected this structure and these premises and found the following corrections needed: kOor SeT eme9u,ph 4,9 bok,45 ..- ,5wpoaro. T 5 i 1ZA4Pf5 titt AlLeS5 41, I) Mel LA) 41 4.-e,P1i Led-rocai &rums k 1 5/0 Oen PalOetch fivi vi Donrietatieo You are hereby notified that the above correction must be inspected before covering. When correction(s) have been made, call for inspecfi,=n at 970-384-5003. Date -- 13 OJ --- Building Inspector Phone (970) 945-8212 20 `4aesia i J l 3 141.1 'uc � 39 APPROVEI SUBJECT TO NOTED XCZPTIONS & INSPECTION 11 GARFIELD COUNTY i, BUILDING DEPA ' EN' BU ,5%3/-o5I ay FIELD COPY MO INSPECTION WITHOM?" NESE PLANS ONSrrTE i c cy„ OiN Y ix 9x .4-' ; v 6 L ac.7i fiosa- 4A/ (1645 ( r/UwrsC.. S`M lSoJ ojt �J/C�an 5 e t/? A k /? "-4keS /1 ./t /-/4 96061 Pelit'AikioN, to, l 46' uS5-5 Rc14JA.,t` fU ,72 / c BUILDING & PLANNING DEPARTMENT Date: August 19, 2008 To: Caleb Edelman 17694 HWY 82 Carbondale Co. 81 623 Dear Permit Holder, Please refer to our previous letter, dated October 3, 2006 , advising you that your Building Permit, number 9489 , was due to expire, per section 106.4.4 & 5 of Uniform Building Code, and that you had been given an additional thirty (30) days to call for the required inspection or to request other action from the building department. The above permit has expired and been closed. The work authorized by the permit has not been inspected or approved. It is a violation of Colorado Revised Statutes 30-28-205 & 210, Uniform Building Code section 109, to used or occupy the building or area unless final inspecitons have been completed and a Cerfiticate of Occupancy has been issued. Records of this failure to comply are included with property records at the Garifield County Clerk and Recorders office. You are intitled to protest this action to the Garfield County Boad of Commissioners. Andy Schwaller Chief Building Official 108 Eighth Street, Suite 401 • Glenwood Springs, CO 81601 (970) 945-8212 • (970) 285-7972 • Fax: (970) 384-3470 Date: /G-3-©6 To: et. / 7� 5't/ Sz 41.4.410.z.04.4 g/ 3 Garfield County Buuocie uompiance u ceTMNT Dear Permit Holder, Please refer to your building permit number rE9' , issued 5:-/9-O5- . A routine review of our open building permits indicates that we have not received a request for an inspection on this permit since A/i Please be advised that building permits expire, per Uniform Building Code, section 106.4.4 and International Code Section 105.5. "Every permit issued by the building official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has commenced for a period of 180 days. Before such work can be recommenced, a new permit shall first be obtained to do so, and the fee therefore shall be one, half the amount required for a new permit for such work, provided no changes have been made or will be made in the original plans and specifications for such work, and provided further that such suspension or abandonment has not exceeded one year. In order to renew action on a permit after expiration, the permittee shall pay a new full permit fee." Please contact this office at your very earliest convenience, in writing, to advise us about the status of your permitted work.. If you have not responded within thirty days from the receipt of this notice the permit will be closed and a permanent notation will be placed in the property records at the County Clerk and Recorders office that indicates that the work permitted per Colorado Revised Statutes 30-28.205 & 210, was not inspected, is not approved and that the building or area is illegal to occupy and is subject to legal abatement action. Thank you for your cooperation. Sincerely,r,T.6i'77U�- Ern Holliday Dave Mead ?Matt Provost Building Inspectors 108 8th Street, Suite 201, Glenwood Springs, Colorado 81601 (970) 945-8212 (970) 285-7972 Fax: (970) 384-3470