Loading...
HomeMy WebLinkAboutEngineer's Report 05.06.2015IDWT ci Dale W. Thome, CO PE 33929 Civil/Structural Engineering & Property Consulting Services 2481 Thunder Mtn. Dr. #61 Grand Junction, CO 81505 970.261.1517 dalethome6Qgmail.com 5.6.15 Garfield County Building Department Glenwood Springs, CO Subject Property: Plus Five Shop/Office Parachute, CO RE: Periodic Occupancy increase (15 employees to 40) with respect to OSWTS Gentlemen, I am in receipt of your request for confirmation for the designed OSWTS to accommodate a periodic occupancy increase. Please consider this letter as confirmation that the system as designed will accommodate a periodic (5 continuous days maximum) occupancy increase of maximum due to the following: I) Infiltrator storage volume will accommodate periodic occupancy (volume) increase with no detrimental effect to soil absorption. 2) 1000 gal. septic tank will provide 1.5 days of detention time for a design flow of 667 gal/day. 40 employees x 15 gal/day (per 8 hour shift) = 600 gal,+day. 600gal/day < 667 galiday OK - Tank will provide adequate detention for periodic increase If any questions or concerns arise regarding this OSWTS, please do not hesitate to contact our office at 970-261- 1517. Respectfully, Dale Thome, PE