HomeMy WebLinkAboutApplication- PermitGarfield County Building & Sanitation Department 108 8th Street, Suite #201 Glenwood Springs, Co. 81601 Office- 945-8212 Inspection Line- 384-5003 Job Address cc,ztk, Nature of Work Building Permit 3 '399 3 B (SO- `a) Use of Building Owner Contractor Amount of Permit $ Date Clerk Permit No: GARFIELD COUNTY BUILDING PERMIT APPLICATION 108 8`k Street, Suite 201, Glenwood Springs, CO 81601 Phone: 970-945-82121 Fax: 970-384-34701 Inspection Line: 970-384-5003 Parcel/Schedule No: c 9 0Oca. l AGREEMENT PERMISSION IS HEREBY GRANTED TO THE APPLICANT AS OWNER, CONTRACTOR AND/OR THE AGENT OF THE CONTRACTOR OR OWNER TO CONSTRUCT `. THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT. IN CONSIDERATION OF THE ISSSUANCE OF THIS PERMIT, THE SIGNER. HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND USE REGULATIONS*ADOPTED BY GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN IN 30.28.201 CRS AS AMENDED, THE SIGNER FURTHER AGREES THAT IF THE ABOVE SMD ORDINANCES ARE NOT FULLY COMPILED WITH IN THE LCOATION, ERECTION, CONSTRUCTION, AND USE OF THE ABOVE DESCRIBED STRUCTURE, THE PERMIT MAY BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT SHALL BECOME NULL AND VOID. THE ISSUANCE OF A PERMT BASED UPON PLANS, SPECIFICATIONS AND OTHER DATii,HALL NOT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING BUILDING OPERATION BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF THS CODE OR ANY OTHER ORDINANCE OR REGULATION OF THIS JURISDICTION. T1IE REVIEW OF SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABLITIES BY GARFIEI» COUNTY FOR ERRORS, OMISSIONS OR DISCREPENCIES. THE RESPONSIBILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICIALLY WITH THE Ai1TICTECT, DESIGNER, BUILDER, AND OWNER. COMMENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS INTEREST. Carfom.003 !F 1 HEREBY ACKNOWLEDGE THAT I HAVE REA AND UNDERSTAND THE AGREEMENT ABOVE (INITIAL): -4---, I CIL IP 3o .7_0 Job Address: jO r1 CIA, / r 3 / 3 (� (/� v /Bllock e 0 CA s 1 -le 1 Lot No: No: Subd. / .Exemption: . 2 Owner i10 a aebs° e- ` 313 3 Ph: C710 -2 cJ 0 P,. --�--'.' 3 on actor: Address: --._ Ph:Lic. No._.,� OW 4, Aron. Address: Ph: Lic. No. ., S Sq. Ft. of Building: 956 S of Lot: J Height: No. of Floors: 6 j � ci,g oaf Use of Building: 6....,k_e_e ry i 7 Describe Work / /" %^/`"i ( 0txj 1 i1 (,--p_ `�?`"(��/j J -c. `. 8 Class of Work: o NewAlteration ❑ Remove to Addition ❑ Move 9 Garage: o SingleCarport: o Double �� ❑ Single II/fa Double 10 ❑ Driveway Permit o On -Site Sewage Disposal o Site Plan (Septic) I1 Valuation of Work: Sr.,'` r •� V/ UG/ f Adjusted Valuations: $ 12 Special. Conditions: F R erim wall 6 4 0414 ALA id Nee7 LIMA/SIF NOTIC A SEPARATE ELECTRICAL PERMIT IS REQUIRED AND MUST BE ISSUED BY THE STATE OF COLORADO. Plan Check Fee: 0 71 3 f t Permit Fee: /1125- TIIIS PERMIT BECOMES NULL AND VOID W WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR, IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A WORK IS COMMENCED. PERIOD OF 180 DAYS AT ANY TIME AFTER W Total Fee: Dated Permit Issued: /� 3. 1/ s(0, I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS GOVERNING THIS TYPE OF WORK WILL BE OCC roll): �QiiSt. Type: j f COMPLETED WITHIN WHETHER SPECIFIED HEREIN OR NOT. TYPE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF NSTRUCTION. /�/ Zoning: Setbacks: .( .;�, c f i, *, d / Manu. }Tome: ISDS No. & Fee: 0 i, t �Ry ij� TE ,i ""i��� �.�I 7 28. BLDG DEPS: PL+ G. DEPT. ' APPROVAL / DATE • "ROYAL / DATE AGREEMENT PERMISSION IS HEREBY GRANTED TO THE APPLICANT AS OWNER, CONTRACTOR AND/OR THE AGENT OF THE CONTRACTOR OR OWNER TO CONSTRUCT `. THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT. IN CONSIDERATION OF THE ISSSUANCE OF THIS PERMIT, THE SIGNER. HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND USE REGULATIONS*ADOPTED BY GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN IN 30.28.201 CRS AS AMENDED, THE SIGNER FURTHER AGREES THAT IF THE ABOVE SMD ORDINANCES ARE NOT FULLY COMPILED WITH IN THE LCOATION, ERECTION, CONSTRUCTION, AND USE OF THE ABOVE DESCRIBED STRUCTURE, THE PERMIT MAY BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT SHALL BECOME NULL AND VOID. THE ISSUANCE OF A PERMT BASED UPON PLANS, SPECIFICATIONS AND OTHER DATii,HALL NOT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING BUILDING OPERATION BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF THS CODE OR ANY OTHER ORDINANCE OR REGULATION OF THIS JURISDICTION. T1IE REVIEW OF SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABLITIES BY GARFIEI» COUNTY FOR ERRORS, OMISSIONS OR DISCREPENCIES. THE RESPONSIBILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICIALLY WITH THE Ai1TICTECT, DESIGNER, BUILDER, AND OWNER. COMMENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS INTEREST. Carfom.003 !F 1 HEREBY ACKNOWLEDGE THAT I HAVE REA AND UNDERSTAND THE AGREEMENT ABOVE (INITIAL): -4---, I CIL IP 3o .7_0 The following items are required by Garfield County for a final inspection: 1. A final Electrical Inspection from the Colorado State Electrical Inspector; 2. Permanent address assigned by Garfield County Building Department posted where readily visible from access road; 3. A finished roof, a lockable house, complete exterior siding, exterior doors and windows installed, a complete kitchen with cabinets, a sink with hot & cold running water, non-absorbent kitchen floor coverings, counter tops and finished walls, ready for stove and refrigerator, all necessary plumbing; 4. A complete bathroom, with washbowl, tub or shower, toilet stool, hot and cold running water, non-absorbent floors and walls finished and a privacy door; 5. All steps outside or inside over three (3) steps must have handrails, guard rails on balconies or decks over 30" high constructed to all 1997 UBC requirements; 6. Outside grading done to where water will detour away from the building; 7. Exceptions to the outside steps, decks and grading may be made upon the demonstration of extenuating circumstances, i.e. weather, but a Certificate of Occupancy will not be issued until all the required items .are completed and a final inspection made; 8. A final inspection sign off by the Garfield County Road & Bridge Department for driveway installation, where applicable; as well as any final sign off by the Fire District, where applicable. A CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. ****CANNOT OCCUPY OR USE DWELLING UNTIL A CERTIFICATE OF OCCUPANCY (C.O.) IS ISSUED, OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. I understand and agree to abide by the above conditions for occupancy, use and the issuance of a Certificate of Occupancy for the dwelling under building permit # Signature Bpcont03/2004 Date GARFIELD CO TY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS for SINGLE FAMILY DWELLING CONSTRUCTION including NEW CONSTRUCTION ADDITIONS ALTERATIONS and MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. Adequate and complete information will prevent delays in the plan review process. Reviewing a plan and the discovery that required information has not been provided by the applicant may result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor may be required to provide this information before the plan review may proceed. This causes delays because other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. If you do not, it may be helpful to obtain a book titled "Dwelling Construction under the Uniform Building Code". This book is available to you through this department at our cost. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following checklist prior to and during design. Applicants are required to indicate appropriately and to submit the completed checklist at time of application for a permit. 1 Plans to be included for a Building Permit, must be on drafting paper at least 18"x24" and drawn to scale. Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks, balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line. A section showing in detail, from the bottom of the footing to the top of the roof, including re -bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house- rap, (which is required), siding or any approved building material. A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, an 80 M.P.H. windshear, wind exposure 13, windload of 15 pounds per square foot, and a 36 inch frost depth. All sheets to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be incompliance with the 1997 UBC, UMC and 1997 UPC. 1. Is a site plan included that identifies the location of the proposed structure or addition and distances to the property lines from each corner of the proposed structure(s) prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Properties with slopes of 30% or greater must be shown on the site plan. NOTE: 106.3.1 (7.) Any site plan for the placement of any portion of a structure within 50 ft. of a property line and not within a previously surveyed building envelope on a subdivision final plat shall be prepared by a licensed surveyor and have the surveyors signature and professional stamp on the drawing. Any structure to be built within a building envelope of a lot shown on a recorded subdivision plat, shall include a copy of the building envelope as it is shown on the final plat with the proposed structure located within the envelope. Yes 2. Does the site plan also include any other buildings on the property, setback easements and utility easements? Please refer to Section 5.05.03 in the Garfield County Zoning Resolution if the property you are applying for a building permit on is located on a corner lot. Special setbacks do apply. Yes 3. Does the site plan include when applicable the location of the I.S.D.S. (Individual Sewage Disposal System) and the distances to the property lines, wells (on subject property and adjacent properties), streams or water courses? Yes I\H'T 4. Does the site plan indicate the location and direction of the County or private road accessing the property? Yes V -P' 2 5. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the uniform building code or per stamped engineered design? Yes 6. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and earth? Yes 7. Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces's and soffits? Yes C� 8. Do. the plans include design loads as required by Garfield County for roof snow loads, (a minimum of 40 pounds per square foot up to & including 7,000 feet above sea level), floor loads and wind loads? Yes 9. Does the plan inc de a building section drawing indicating foundation, wall, floor, and roof construction? Yes 10. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters a joists or trusses? Yes 11. Does the building section drawing or other detail include the method of positive connection of all columns arel'beams? Yes 12. Does the plan indicate the height of the building or proposed addition from the highest point of the building or addition measured at mid span between the ridge and the cave down to existing (undisturbed) grade contours? Yes (� cV 13. Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase 11 certifications or phase 11 EPA certification? Yes No 14. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the Uniform Building Code Chapter 37? Yes No -- 3 15: Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements comply with the requirements of the Uniform Building Code? !n' Yes No 1f'[ 16. Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable rooms? Yes _ No 17. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety glazing for these areas? Yes No 18. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? Yes No 19. Do you understand that if you are building on a parcel of land created by the exemption process or the subdivision process, are building plans in compliance with all plat notes and/or covenants? Yes No 20. Do you understand that if you belong to a homeowners association, it is your responsibility to obtain written permission from the association, if required by that association,prior to submitting an application for a building permit? The building peuliit application will not be accepted without it. Yes No 21, Will this be the only residential structure on the parcel? Yes No If no -Explain: NA 22. Have two (2) complete sets of construction drawings been submitted with the application? Yes 23. Do you understand that the minimum dimensions a home can be on a lot is 24ft.wide and 20ft.lang? Yes . No 24. Have you designed or had this plan designed while considering building and other construction code requirements? Yes No 4 25. Do your plans complywith all zoning rules and regulations in the County related to your properties zon district? Yes ' No 26. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by the Garfield County Building Department? Yes \/ No 27. Do you understand that approval for design and/or construction changes are required prior to the applicatiyin of these changes? Yes 1 No 28. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application submittal and that you will be required to pay the "Permit Fee" as well as any " oad Impact" or "Septic System" fees required, at the time you pick up your building pe it? Yes No 29. Are you aware that twenty-four (24) hour notice is required for all inspections? Inspections will be made from Battlement Mesa to West Glenwood in the mornings and from Glenwood Springs to Carbondale in the afternoons. All inspections must be called in by 3:30 p.m. the day before. Failure to give twenty-four (24) hour notice for inspections will delay your inspection one (1) day. Inspections are to be called in to 384-5003. Yes J No 30. Are you aw re that requesting inspections on work that is not ready or not accessible will result in a 47.00 re-inpsection fee? Yes 1 No 31. Are you aware that you are required to call for all inspections required under the Unifouu Building Code including approval on a final inspection prior to receiving a Certificate of Occupancy d occupancy of the building? Yes No 32. Are you aware that the Peaiit Application must be signed by the Owner or a written authority be gi en for an Agent and that the party responsible for the project must comply with the Uni rm Building Code? Yes t No 33. Are you aware as part of the submittal for a building permit you are required to show proof of a driveway access permit from Garfield County Road & Bridge Department or if applicable the State Highway Department ? If a permit is not necessary, then a letter stating that information is required. You can contact the Garfield County Road & Bridge 5 Dep.artment at 625-8601 or refer to the phone book for the State Highway Departments phone number. Yes No 34. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups, unless you as the homeowner are performing the ork? The license number of the person performing the work will be required at tim of applicable inspection. Yes No 35. Are you aware, that on the front of the Building Permit Application you will need to fill in the Parcel/Schee ule Number for the lot you are applying for this permit on prior to submittal of a building . irmit application? Your attention in this is appreciated. Yes No 36. Do you know that the local fire gYistriet may require you to submit plans for their review of fire safety issues? Yes No (please check with the building department about this requirement) 37. Are you aware, that if you receive your water and/or sewer from an Association, District, or Municipality you will be required to provide the County with a copy of the Tap Permit {or evidence of an exemption) at the time of the building permit 'application submittal? Yes No N/A ate/ 38. If you are within five {5) miles of the City of Rifle or the Town of Parachute, have you checked with them concerning water shed protection zone permit requirements for T DS and other activities? Yes No N/A I hereby acknowledge that X have read, understand and answered these questions to the best of my ability. Signature of Owner Dat r9/14 Phone: 3 0_ 0 2 (days); 3- rL_9.„ (evenings) Project Name: Project Address: 44,190 Notes: If you have answered "No" on any of the questions, you may be required to provide this information at the request of the Building Official prior to beginning the planreview process. Delays in issuing the permit are to be expected. Work may not proceed without the issuance of a PLAN REVIEW CHECKLIST Applicant 44 r,,, L LN, g Date 7- z, Building Planning/Zoning It/./Engineered Foundation Property Line Setbacks // /1 Driveway Permit 30ft Stream Setbacks ,.7Strscoyed Site Plan `j 0 Flood Plain 4 Septic Permit and Setbacks Building Height A Lt Aprrade/Topography 30% Zoning Sign -off ./Attach Residential Plan Review List Road Impact Fees Xfinimum Application Questionnaire HOA/DRC Approval * ASubdivision Plat Notes Grade/Topography 40% )1,1, &Fire Department Review Planning Issues ..�'Valua 'on Determination/Fees Subdivision Plat Notes ed Line Plans/Stamps/Sticker /V4Attach Conditions ,----41--;plication Signed Plan Reviewer To Sign Application u, f Water and Sewer arcel/Schedule No. 40# Snowload Letter- Manf. Hms. GENERAL NOTES: No Assessor's Parcel No;5 '--c,`�` i -C --CY01 Date 0--C-C4` BUI D G PERMIT CARD Job A•tdresR a boilio C :.d-'- %15 , Owner \( !,,tA bit nal&Werficv Address Phone # Address Phone # Setbacks: Fropt Rear RH LH Zoning --'U ,� i.ab.-,_; INSPECTIONS Soils Test Footing Mechanical Foundation Electrical Rough (State) Grout Electri .1 F'/.I tate) Underground Plumbing Final % - - %i/Checklist Completed? ContractorD `' V Weatherproofing Rough Plumbing Certificate Occupancy # Framing 14)&1k- Date Insulation Septic System # Roofing Date Drywall Final Gas Piping Other NOTES (continue on back) JUL-13-2004 11:21 Duane Boice RE, President July 13, 2004 GRUEN-WALD & STS Engineering & Technical Services Inco 606 498 1299 P.02 Ms, Florence Me Cullough 6600 County Road 313 New Castle, CO 81647 Re: Sun -Porch Structure Order #26647/Model DDX1530 Dear Ms. Mc Cullough: This letter is to certify that Engineering & Technical Services, Inc., has performed a structural review of the Sunporeh, which is designed in accordance with the 1997 Uniform Building Code (UBC),1999 National Building Code (BOCA), 1997 Standard Building Code (SBCCI), and the. 2003 International Residential Code (IRC) Section 11 Patio Covers, The strOcturc evaluated above was a lean-to model with aprojection up to 12 feet, The structural members are constructed of 6063-T6 aluminum alloy tubular rafters and verticals spaced at three-foot modular centers. The rafters are 1-1/2" wide by 4-1/2" deep with an alurnantun I—Beam insert. The uniform roof slope of the rafters is 1-1/2 to 12. There is a post in the center of the 12' span effectively reducing the span to 6'.. Our analysis shows that the frame components will safely support the structures dead load plus auniformly distributed roof load of 90 psf for roof spans up to 9', 50 psf for roof spans up to 12' and 45 psf for roof spans up to 15' in combination with forces from a wind speed of C exposure -100 mph blowing in any direction. The Sun. -Porch is in compliance with the Voluntary Specifications for Sunrooms AAMA/NPEA/NSA 2100- 02. It is classified in Section 3 as a Caategoty 111 sunroom. It has a separation wail from the adjacent structure, unconditioned, used for recreational, outdoor living space and is considered non -habitable. The glazing materials are shatter resistant. Roof dead Toad is approximately 3 psf. The roof glazing consists of panels of extruded double-wall polycarbonate made by General Electric under the trade name Lexan ICBO report ER -3286, The wall glazing is Durapiex acrylic mounted in aluminum framed panels ICBG report ER - 6042. Our Eng',., -rs are available for further consultation as may be recite Wi . Rei.; • s, .m°°� THE FOLL COVERS MC CULL _ v 6600 CO TY RT91,13. 3 Duane D Boice, PE, President NEW CASTLE, Cq,l�547 a6 Engineering & Technical Services, Inc. `�-4iA , 27121 469th Ave. Tea, SD 570644100 Prone: (605) 498.1290 Fax: (605) 4984299 E»mail: etsl@dtgnet.com ' www.engtecsrv.com TOTAL P.02 Uncovered Single Family Residential Decks and Porches • ix Or z xDeckin �ts Nati to. Joists pr iii va:ztsad Deck Nails oz -Esistint Bldg. 3.6 1 with tests or Int, Rang Spaced so that yi Taft Dienwater'Sphocre -Cannot t Pm Ittroogitt 37 rJoists std lacteal co Ceazar .ani�.ad Metal; Joist �f See Detail "A" s t Note: If an exit or egress from the existing building passes under the proposed deck, or if there is and existing patio under the proposed deck, a ruinimutn clear headroom of not less that 6ft. Sin. must be maintained under the beam. Please indicate openings in existing wall. OVELI SUBJECT TO NOTED cal co lad See Detail "S` Spare. See Detail "`G" Gracie Levet B,e CFIELD COUNTY BUILDING -fDEPAN�TMEN". te 715. �4 By _AA FIELD COPY 14.0 SPECTION WITHOUT Its -PLANS ON 311ItE Qs Nttee 36 Inches Min. 1 DECKSECTION 8 inch (MTh) Mame- Cg- 3i iame- C'_3I Note: A floor plan (plan view) showing the dimensions of your project or addition and its relationship to existing buildings or structures on the property must be included. In addition to ;project dimensions, your floor plan must also show other details such as post locations and spacing, ether pertinent information not shown on the sectional drawing. 77 Uncovered Single Family Residential Decks and Porches Bldg. Nall to Joists with Galvanised Dec Nails or Scilly to Johns with Non rosin, &views Galvanized rat ;oh: Mawr Bolted to itzistIng - Lac 16 �. Joist or est wf DETAIL "A" tag Boit, Raillne to a Gelzganizoo. Metal Galvanized Mrd Joist Hamer X Pncrc DETAIL "1" ALT. DETAIL "B" 1/2* Dlametmr Anctoc Bolt E ab.dded 7" Min. Into Caom-sts Pita Or The Equivalent DETAIL "C" ALT. DETAIL "B" Pgsts Calvan.i ed Mecsl Fest Act 6" ruin. If less than 6", post mss= tressed or recfww 8 inch (MIN) Diameter Fier 4 v r - L v' ‘rd iN\ r 8 0 vt :4 ill Gel 7 1) tik Uncovered Single Family Residential Decks and Porches Open Guardrails and Open. Handrails on Decks and S tairways More Than 30 Inches Above Grade or a Floor Below Shall Have Pickets or Intermediate Rads Spaced so that a 4 Inch Diameter Sphere Cannot Pass Through. Stairway Notes: 1. Stairways shalt be not less than 36 inches in width. 2. Stairway risen shah be not less than. 4 inches nor greater than 8 inches. 3. Stairway treads sisals have a minimum run of 9 inches. - 4. The greatest riser height and largest tread run is a stairwec' shall not exceed the smallest by more than 3/8 inch. CO Handrail (See Details Below) inches Mln. Run Inches Min./8 Inches Max. Rise Handrail Notes: 1. Handrails shall be continuous on at least one side of stairs with 4 or more :rises. 2.. Handrails -shall be placed not less than 34 inches nor more than 38 inches above Stair nosing!. 3. The handgrip portion of handrails shall be not less than 1-1/4 incises nor more than 2 Inches In dimension. 4. Handrails shall be placed not less than L-1/2 inches. from any wail or other surface. Not Less Than Width of Stairway , r7;„p: _i..e• .4 .. Grade Level Landing 1-1 /4 to 2 Inches 1-1/2 Inches Min.. Acceptable Handrail Details 1-1/2 Inches Min. Wall or Other Surface wail or Other Surface NOT ACCEPTABLE STAIR AND HANDRAIL SPECIFICATIONS