HomeMy WebLinkAboutApplicationI 2 3 4 5 6 7 8 9 C7-C¥.rfieZd C:o~rz~ J /08 8'• Street, Suite 40/, Glenwood Springs, CO 81601 Ph :970-945·82/2 Fx:970-384·3440 lnspectio11 Line:888-868·5306 www.garfie ld -county .com BUILDING PERMIT APPLICATION Parcel No : (tliis information is a•'ftilable at tl1e assessors office 970-9-#J-9/J~ I Lot No: Block No: Subd./ Exemption: 2181-172-00-086 Job Address: (i/ an address /1as not been assigned, please pro•·ide CR. HWY or Street Name & City) or and legal dcscriplion T6S-R91W-West of the Town of New Castle on County RD 335 Owner: (property owner) Mailing Address: 1288 county Rd 245 Ph: Alt Ph: Richard ' Mary Jolley Family LLL~ New castle.co 81647 970·984·3562 Contractor: Mailing Address: Ph: Alt Ph: TBD Manufactured home installer: Mailing Address: Ph: Lie#: Architect: Mailing Address : Ph: Alt Ph: Engineer: Mailing Address: 670 Canyon Creek Dr Ph: 970-250-5505 Alt Ph: Fox Engineering Solution Grand Junction,C0815 P3 Sq. Ft. of Building: Sq. Ft. or Acres of Lot : Height: No. of Floors: Use of Building: DResidential OCommercial OOther I Class of Work: ~New OAlteration DAddition DRenair DDemo DMove IO Describe Work: Installation of a Fence to satisfy COA #7 Attached as exhibit to this permit LIR resolution #2010-27 II Garage: I Septic: Type of Heat: DAttached DDetached OISDS OCommunity DNat.Gas OPropane DElectric OOther 12 Driveway Permit: ~wners valuation of Work: 2,500.00 NOTICE ~. This application for a Building Penni\ musl be signed by the Owner oflhe propcny, described above, or an authorized agent If lhc sii;na1un: below is nol lhal of the Owner, a scparale lcltcr of authority, signed by the Owner, musl be provided with this Application. Lua! A«tJ•· A Building Pcnnil cannol be issued wi1hou1 proof oflcgal and odcquale accc" 10 the propcny for pu1pOscs ofinspcctions by 1hc Building Department. Otbrr Prrml!1. Mulliplc separate pcnnilS may be requiRd: (I) Slalc Electrical Pcnnil. (2) County ISDS Penni!, (3l another pcnnil required for use on lhc propctty identified above, cg. Slale or County Highway/ Road Access or a Slalc Wastewater Discharge PenniL Vold Perm!!. A Building Penni\ becomes null and void ifd1e work aulhorizcd is not commenced within 180 days of the date ofissuance and if work is suspended or abandoned for• period of 180 days after commencement. C£RTIFJCA TJON I hereby cenify lhlr I have read this Appliotion and lhll the infonnalion conaincd above is true and correct. I undcnand 11181 the Building Dcpanment acccplS the Application, along with 1hc plans and specifications and ocher dala submitted by me or on my behalf (submiuals), based upon my ccttificalion as to accuncy. Assuming completeness of the submiuals and approval of thiJ Appliolion, a Building Pcnni1 will be issued gnint ing permission to me, as Owner, to construct the structU«(s) and facilities detailed on the subminals rcvic~ by the Building Department. In considctalion of the issuance of1he Building Permit. I ai;rcc lhal I and my agents will co1111ly wilh provisions of any federal, sllte or local law rcgulaling the work and the Garfield County Building Coclc, ISDS regulations and applicable land use regulations (County Regulation(s)). I acknowledge that the Building Pcnnit may be suspended or revoked, upon nolite ftom the County, if the location. conslruction or use of the slructure(s) and facility(ics), described above, are not in compliance wilh County Regulation(s) or any other applicable law. I hereby gninr permission 10 die Building Department lo enter the propctty, dcscn'bcd above, lo inspect the work. I further acknowledge that the issuance of die Building Pcrmil docs not prevcnl lite Building Official from: (I) requiring the com:ction of ermrs in 1hc submiuals, ihny, discovered after issuance; or (2) stopping constiuc1ion or use of die struelun:(s) or facili1y(ics) if such is in violation of County Rcgula1ion(s) or any other applicable law. Review of1his Applicalion. including submillals, and inspections of the work by the Building Dcpartmcnl do not constitute an ecccptancc of responsibility or liability by lhc County ofcrron, omissions or discrepancies. As the Owner, I acknowledge tha1 responsibility for compliance with fcde,.I, slale and local laws and County Rcgul11ions resl with me and my aulhoriz.ed agcnlS, including wilhoul limitarion my archilccl dcsii:ncr. engineer and/ or builder. I HEREB 'l.CKN~E THAT I HA VE READ AND UNDERSTAND THE NOTICE & CERTJRCATION ABOVE: R-_n ~ :t:I R. "M -·J . 11 -/I •OWNERS SIGJfO'URE DATE -3.1·11 ·1~~ ~'(J .(/.II Adjusted Valuation : Plan Check Fee: Pennlt Fee: Manu home Fee: Misc Fees: '2-;Soo . oo 5L/ _,, Bj.2.S- Total Fees: Fees Paid: Balance Due: BP No IIt Issue Dale: ISDS No & Issued Date: 137. 3fo 4.'' B3. z.S--Oi27 jJ A Setbacks: OCCGroup: Const Type: Zoning: u APPROVAL DATE GARFIELD COUNTY BUILDING REQUIREMENTS Codes: 2009 IRC, me, IFGC, IMC, IPC, 2009IECC. Setbacks: Check subdivisions and zone district for setback requirements. Snowload (measured at the roofl Not ground): 40PSF up to 7000ft. elevation. SOP SF 700 I ft to 8000ft. 75PSF 8001 ft to 9000ft. IOOPSF 9001 to lOOOOft. !!! ALL SNOWLOADS ARE MEASURED HORIZONTALLY AT THE ROOF NOT THE GROUND!!! Seismic design category: B Weathering probability for concrete: Severe. Termite infestation probability: None to slight. Wind speed: 90mph. Decay probability: None to slight Wind Exposure: B or C (see section R301.2.1.4) Frost Depth: 36in. to 8000ft. elevation. 42in. 8001 and above. Winter Design Temperature: Minus 2 to 7000ft.; minus 16over 7000ft. elevation. Air Freezing Index: 2500deg F-days to 7000ft.; over 7000ft. to be determined by Building official Ice shield under-layment required. Mean Annual temp: Variable SEE 2009 IECC FOR INSULATION AND ENERGY REQUIREMENTS. GARFIELD COUNTY Building & Planning Department 108 8th Street, Suite 401 Glenwood Springs, Colorado 81601 ---~ Telephone: 970.945.8212 Facsimile: 970.384.3470 www .qarfield-countv.com COMMERCIAL OR MUL Tl-FAMILY BUILDING PERMIT NOTE: In order to understand the scope of work intended and to expedite the issuance of a permit, it is important that complete information be provided. Please review this document to determine if you have adequate information to design your project and to facilitate a plan review. COMMERCIAL OR MULTI-FAMILY BUILDING PERMIT APPLICATION CHECKLIST This checklist is to be used with all commercial or multi-family construction. APPLICATION FORM: Please make sure the following information is provided on the application. • Parcel number obtained from the County Assessor's Office. • Job address (assigned physical address). • Legal Description: lot, block, filing, subdivision or tract, section, township and range. • Owners name, mailing address, phone, fax, or cell. • Contactors name, mailing address, phone, fax, or cell. • ArchitecUEngineer's name, mailing address, phone, fax or cell. • Building size, height, number of stories, lot size. • Use of building (commercial) • Class of Work (new, addition, alteration, repair, demo, move, other) • Description of work. • Type of heating (natural gas, propane, electric, other) • Sewer system (Community or ISDS), also see other items below. • Garage (attached or detached) • Driveway permit (please see other items below) • Valuation (labor and materials) OTHER ITEMS: • If you anticipate obtaining a water-tap from the City of Rifle, please provide a letter indicating that the City will provide water service. (Required to submit building permit application). • ISDS requires a septic permit application to be submitted with the building permit application. • A separate electrical permit must be obtained from the State of Colorado Electrical Board. • Prior to submittal of a building permit, you are required to show proof of legal and adequate access to the site. This may include proof of right to use a private easement, County Road & Bridge permit, or Colorado Department of Highway permit, including a Notice to Proceed. The County Road & Bridge Department can be reached at 970-625-8601. • If you anticipate excavating or grading prior to issuance of a building permit, you will be required to obtain a separate grading permit. • If you belong to a Homeowners Association (HOA), it is your responsibility to obtain written approval, if required. • Provide copies of any Resolutions and/or Land Use Permits associated with this property. • Projects with more than ten (10) occupants require plans sealed by a Colorado Licensed Design Professional. Occupant load shall be calculated by IBC Table 1004.1.1. • A Colorado State Licensed Electrician and Plumber must perform installation and hook-ups. BUILDING PLANS: Two (2) sets of plans must be submitted. Plans must be 18"x24" minimum size, complete, identical, legible, and to scale. Certain projects may also require a third copy of the plans be submitted to the local Fire District for review prior to permit issuance. All plans will be checked at the counter for completeness. If any of the required information is missing, the building permit application cannot be accepted. SITE PLAN: Please make sure the following information is provided on the site plan. • Property address/legal description. • North Arrow and Scale on each page. • Show all property lines, building envelopes, flood plain, and easements. • Provide setback distances from boundaries, buildings, septic, well, and waterways. • Location and direction of the county or private road and driveway accessing the property. • Proposed and existing structures include sheds, barns, decks, patios, and any other buildings. • Existing and proposed grade, positive drainage around structure (to be contained on site). • Streams, rivers, creeks, springs, ponds and ditches. • Existing and proposed wells, septic tanks, leach fields, and other systems. (if applicable) • Retaining walls (engineer stamped detail required for walls over four {4) fl, measured from bottom of footing to top of wall). NOTE: Any site plan depicting the placement of any portion of the structure within fifty (50) feet of a property line or not within an established building envelope shall be prepared, stamped, and signed by a licensed surveyor. For structures to be built within a building envelope, provide a copy of the recorded subdivision final plat with the proposed structure located in the building envelope. COVER SHEET: • Project identification. • Project address and/or legal description. • Design specifications to include building use and occupancy classification, type of construction, building height and area calculations, occupant load, and fire sprinkler systems. ARCHITECTURAL PLANS: Please provide the following information on the architectural plans. • Per C.R.S. 12-4-112; Structures designed with an occupant load exceeding ten {10) require Colorado State Licensed Design Professional stamped plans. • Minimum four (4) elevations (N,S,E,W) • Floor plans for each level including dimensions and scale noted. • Clearly label each room or space (office, storage, mechanical, elevator, etc). • Wall types; clearly labeled and referenced. Identify all fire resistive wall construction. • Construction details for all fire resistive elements referenced on floor plans and cross sections. Include wall, floor/ceiling, roof/ceiling, shaft wall assemblies, and structural frame. Provide the fire resistive listing number referenced on each assembly detail. (ex. UL P123) • Window & door sizes, types, and operation and direction of swing noted on the floor plan. • Specify roof slope/pitch, roof covering, and siding materials. • Energy design specifications/details for R-values, LI-factors, and SHGC's per JECC. • Stair and guard details specifying rise, run, height and spacing. • Accessibility; show compliance with accessibility requirements for all elements of the building per IBC, Chapter 11 and ICC/ANSI A 117.1, ADA, FHA, and UFAS. STRUCTURAL PLANS: Please provide the following information on the structural plans. • Per C.R.S. 12-4-112; Structures designed with an occupant load exceeding ten (10) require Colorado State Licensed Engineer stamped plans. • Engineered foundation design per soils report. Geotechnical report referenced. • Design specifications to include roof and deck snow load, wind and seismic design, frost depth. • Foundation plan showing complete footing and foundation dimensions. • Footing and foundation details specifying reinforcement referenced on plans. • Framing plans for each floor level and roof. All beams, columns, joists, rafters, trusses and all live/dead loads specified. • Framing /connection details referenced on plans. • Pre-manufactured structures require an engineers stamp, signature, and date. MECHANICAL PLANS: Please provide the following information on the mechanical plans. • Per C.R.S. 12-4-112; Structures designed with an occupant load exceeding ten (10) require Colorado State Licensed Engineer stamped plans. • Energy design calculations and details verifying compliance with the 2009 IECC. • Floor plans for each level showing size, location and materials of all ductwork, plenums, return and outside air intake registers. • Size and location of all combustion air ductwork and openings. • Size, type and termination of all gas appliance flues and vents. • Location of all fire and combination smoke/fire dampers. • Equipment schedule for all mechanical equipment (boiler, furnace, exhaust fans, etc). • Commercial kitchen hood location, hood and duct sizes, CFM calculations. PLUMBING PLANS: Please provide the following information on the plumbing plans. • Per C.R.S. 12-4-112; Structures designed with an occupant load exceeding ten (10) require Colorado State Licensed Engineer stamped plans. • Floor plans for each level showing DWV layout and sizing, materials, slope and sewer location . • Water piping materials, length and size of pipe, water meter location, fixture unit demands, location and type of backflow prevention devices. • Gas piping materials, length and size of pipe, gas meter location, and BTU/hour demands. • Additional piping plans for roof/deck drains, condensate, medical gas, etc. • Plumbing fixture schedule for all plumbing equipment. • Commercial kitchen plumbing fixtures, food preparation equipment, grease interceptors, etc. ELECTRICAL PLANS: Please provide the following information on the electrical plans. • PerC.R.S. 12-4-112; Structures designed with an occupant load exceeding ten (10) require Colorado State Licensed Engineer stamped plans. • Floor plans for each level showing location of lighting fixtures, switches, receptacles, emergency exit signs and lighting, and panel location. • Diagram showing service entrance, conduit/wire size, main disconnect size, grounding electrode/conductor size, feeder conduit/wire size, transformers and generators. • Panel schedule showing bus/breaker sizes, circuit description, voltage, phase, amperage, etc. NOTE: If any required information is missing, delays in issuing the permit are to be expected. If determined by the Building Official that additional information is necessary to review the application and/or plans for compliance, the application may be placed on hold until the required information is provided. Work may not proceed without the issuance of a permit. The building department will collect a Plan Review fee at time of application submittal. The Permit Fee. as well as any Septic or Road Impact fees will be collected when the permit is issued. The permit application must be signed by the owner or by a person having written authority from the owner to act as their representative. I hereby acknowledge I have read, understand, and will abide with the requirements of this checklist. !-/! Date Garfield County Building & Planning 108 8th Street, Suite 401 Glenwood Springs, CO 81601 Phone: 970-945-8212 Fax: 970-384-3470 www .garfield-county.com