Loading...
HomeMy WebLinkAboutApplication-PermitI Garfield County Building & Planning Department 108 8th Street, Suite #401 Glenwood Springs, Co. 81601 Office:970-945-8212 Fax: 970-384-3470 Inspection Line: 970·384-5003 Building Permit No. Parcel No: __ ___,2::_:.12_~-302-00-144 __ ---- Locality: Job Address: ---~------···0,:.:4_.:.:80:.:E::::Ik~R...::u::.:ncc.c~=~N-=-ew:.:..=.Ca=,s:_::tl_e: ______________ _ Use of Building: Garage/ sho[l ______ ~ Owner: Greene, T_h_ad & Denise Contractor: Owner Fees: Plan Check: 326.53 Septic: Bldg Permit: 502.35 Oth~r Fees: Total Fees: $ 828.88 --· Clerk: ))cH:_: \( Date: l.\-0 1-C15 ____ I GARFIELD COUNTY BUILDING PERMIT APPLICATION 108 8"' Street, Suite 401, Glenwood Springs, Co 81601 Phone: 970-945-8212/ Fax: 970-384-3470 I Inspection Line: 970-384·5003 www.garfield~county.com Authority. This application for a Building Permit must be signed by the Owner of the property, described above, or an authorized agent If the signature below is not that of the Owner, a separate letter of authority, signed by the Owner, must be provided with this Application. Legal kress, A Building Pennit cannot be issued without proof oflega1 and adequate access to the property for purposes of inspections by the Building Department. Other Permjt:s. Multiple separate permits may be required: (l) State Electrical Pennit, (2) CoWlty ISDS Pennit, (3) another permit required for use on the property identified above, e.g. State or County Highway/ Road Access or a State Wastewater Discharge Permit Void Permit. A Building Pennit becomes null and void if the work authorized is not commenced within 180 days of the date of issuance and ifwotk is suspended or abandoned fur a period of 180 days after commencement CERTIFICATION I hereby certify that I have read this Application and that the infonnation contained above is true and correct I understand that the Building Department accepts the Application, along with the plans and specifications and other data submitted by me or on my behalf (submittals), based upon my certification as to accuracy. Asswning completeness of the submittals and approval of this Application, a Building Pennit will be issued granting pennission to me, as Owner, to construct the structure(s) and facilities detailed on the submittals reviewed by the Building Department In consideration of the issuance of the Building Permit, I agree that I and my agents will comply with provisiOns of any federal, state or local law regulating the work and the Garfield County Building Code, ISDS regulations and applicable land use regulations (County Regulation(s)). I acknowledge that the Building Pennit may be suspended or revoked, upon notice from the County, if the location, construction or use of the structure(s) and fucility(ies), described above, are not in compliance with County Regulation(s) or any other applicable law. I hereby grant pennission to the Building Department to enter the property, described above, to inspect the work. I further acknowledge that the issuance of the Building Permit does not prevent the Building Official from: (1) requiring the correction of errors in the submittals., if any, discovered after issuance; or (2) stopping construction or use of the structure(s) or facility(ies) if such is in violation of County Regulation(s) or any other applicable law. Review of this Application, including submittals, and inspections of the work by the Building Department do not constitute an acceptance of responsibility or liability by the County of errors, omissions or discrepancies. As the Owner, I acknowledge that responsibility fur compliance with federal, state and local laws and County Regulations rest with me and my authorized agCDts, including without li~:~:::~~~:~~;~~\-~~ ;;l'!~";' and! or builder. I lA T u VB READ AND UNO ERST AND TilE NOTICE & CERTIFICA :ION ABOVE: ~ /0 fV114.1Z.e_J/ 06 STAFF USE ONLY Special Conditions: Adjusted Valuation: Plan Check Fee: Permit Fee: Manu home Fee: Mise Fees: 3C.. ()O c) '3?-t.. ~ 5o2 3) /0 If'" ISDSFee: T;~;;: ~~ Fees Paid: Balance Due: BP No & Issue Date: ISDS No & Issued Date: t7 3~lo.S3 50'2-'35"" \0~60> - SetbackS: OCCGroup: ConstType: Zoning: ~-C BLDG DEPT: PLNGDEPT: v1 ~u ~ .\/ ';-'J-1-0~ ~~\ ~ -?,'1-o'i( 1m ~l DATE APPR<WAn 1 DATE The following items are required by Garfield County for a fmal Inspection: I) A final Electrical Inspection from the Colorado State Electrical Inspector. 2) Permanent address assigned by Garfield County Building Department and posted at the structure and where readily visible from access road. 3) A finished roof; a lockable building; completed exterior siding; exterior doors and windows installed; a complete kitchen with cabinets, sink with hot & cold running water, non-absorbent kitchen floor covering, counter tops and finished walls, ready for stove and refrigerator; all necessary plumbing. 4) All bathrooms must be complete, with washbowl, tub or shower, toilet, hot and cold running water, non-absorbent floors, walls finished, and privacy door. 5) Steps over three (3) risers, outside or inside must be must have handrails. Balconies and decks over 30" high must be constructed to all IBC and IRC requirements including guardrails. 6) Outside grading completed so that water slopes away from the building; 7) Exceptions to the outside steps, decks, grading may be made upon the demonstration of extenuating circumstances., i.e. weather. Under such circumstances A Certificate of Occupancy may be issued conditionally. 8) A final inspection sign off by the Garfield County Road & Bridge Department for driveway installation, where applicable; as well as any fmal sign off by the Fire District, and/or State Agencies where applicable. A CERTIFICATE OF OCCUPANCY (C.O.) WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. A C.O. MAY TAKE UP TO 5 BUSINESS DAYS TO BE PROCESSED AND ISSUED. OWNER CANNOT OCCUPY OR USE DWELLING UNTIL A C.O. IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. I understand and agree to abide by the above conditions for occupancy, use and the issuance of a C.O. for the building identified in the Building Permit. OWNERS SIGNATURE Bapplicationdecember2007 DATE VALUATION FEE DETERMINATION Applicant Address Date -;Gr~ee:;'n';:;e-;;-;;;--::-.,-------_;_-Subdivision 0480 Elk Run Rd. Lot/Block -;3~/2:':7:'::/2:000:0'::8==:!:._--------Contractor Finished (Livable Area): Main Upper Lower Other Total Basement: Unfinished Square Feet Valuation Conversion of Unfinished to Finished Total Valuation Garage: Valuation Crawl Space Valuation Decks/ Patios Valuation Covered Open Type of Construction: Occupancy: Valuation Total Valuation sf sf sf sf X $74.68 0 sf sf X $41.00 sf X $33.68 2000 sf X $18.00 Commercial sf X $9.00 sf X $24.00 sf X $12.00 sf X sf X sf X sf X sf X sf X Greene Exemption I Owner 0.00 0.00 36,000.00 0.00 0.00 0.00 36,000.00 GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS For SINGLE FAMILY DWELLING CONSTRUCTION Including NEW CONSTRUCTION ADDITIONS ALTERATIONS And MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. When reviewing a plan and it's discovered that required information has not been provided by the applicant, this will result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor shall be required to provide this information before the plan review can proceed. Other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. TWO (2) SETS OF CONSTRUCTION DRAWINGS & TWO (2) SITE PLANS MUST BE SUBMITTEDFOR ALL APPLICATIONS. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. Any project with more than ten (10) occupants requires the plans to be sealed by a Colorado Registered Design Professional. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following checklist prior to and during design. Applicants are required to indicate appropriately and to submit the completed checklist at time of application for a permit. Plans to be included for a Building Permit, must be on drafting paper at least 18"x24" and drawn to scale. I Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks, balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line and original grade. A section showing in detail, from the bottom of the footing to the top of the roof, including re-bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house-rap, (which is required), siding or any approved building material. Engineered foundations may be required. A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. wind speed, wind exposure B or C, and a 36 inch frost depth. All sheets to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be incompliance with the 2003 IRC. I. Is a site plan included that identifies the location of the proposed structure or addition and distances to the property lines from each corner of the proposed structure(s) prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Properties with slopes of 30% or greater must be shown on the site plan. (NOTE Section: 106.2) Any site plan for the placement of any portion of a structure within.JQ.it. of a property line and not within a previously surveyed building envelope on a subdivision final plat shall be prepared by a licensed surveyor and have the surveyor's signature and professional stamp on the drawing. Any structure to be built within a building envelope of a lot shown on a recorded subdivision plat shall include a copy of the building envelope as it is shown on the final plat with the proposed structure located within~ Slll:lfelope. Yes t 1rt ,//. 2. Does the site plan also include any other buildings on the property, setback easements and utility easements? Please refer to Section 5.05.03 in the Garfield County Zoning Resolution if the property you are applying for a building permit on is located on a corner lot. Special setbacks do ~!ly.'/.i,Lj 3. Does the site plan include when applicable the location of the I.S.D.S. (Individual Sewage Disposal System) and the distances to the property lines, wells (on subject property and adjacent prope~} §Jrearns or water courses? yes n.JJ. rJ4. 4. Does the site plan indicate the location and direction of the County or private road accessing the propert:tyUU " Yes .~ r·JJ~ 2 5. Are you aware that prior to submittal of a building permit application you are required to show proof of a legal and adequate access to the site? This may include (but is not limited to) proof of your right to use a private easement/right of way; A County Road and Bridge permit; a Colorado Dept. of Highway Permit, including a Notice to Proceed; a permit from the federal government or any combination. You can contact the Road & Bridge Department at 625-8601. See phone book for other~if!s Yes t· ~ y, 6. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accoiJI!!IlcQ,VWith the IRC or per stamped engineered design? Yes 1/Af.,LL, 7. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clear~~Jequired between wood and earth? ::5t.A13 orJ tl.rz-kl?lf: (., ~ol) . ...,.~ Yes /. 'f/.11, No. ____ _ 8. Do the plans indicate the size and location of ventilation openings for the ,!!1.tic, roof joist spaces and soffitsd 11 n 1 91 Yes ~~ 'fr'LA~o ____ _ 9. Do the plans include design loads as required by Garfield County for roof snow loads, (a minimum of 1Q. pounds per square foot up to & including 7,000 feet above sea level), floor loads and wind loads? ,.....-;:; 1 Qt /' .,, 14 ~MI ""-...-. /J yes /. • IN,..,;!. '-P IJcn--;:;>=-<--nz,.<~~ DW<>~. I 0. Does the plan include a building section drawing indicating foundation, wall, floor, and roof constru~9~ Yes ;.W. II. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof r~s oriJoists or trusses? Yes u1..AA. 12. Does the building section drawing or other detail include the method of positive connection of all column~? ~pams? Yes 1.1/J:L 13. Does the elevation plan indicate the height of the building or proposed addition from the undisturbed grade to the midpoint between the ridge and eave of a gable or shed roof or the top of a fl~?f1 (Building height measurement usually not to exceed 25 feet) Yes t!JJ.,o. zz'-if 14. Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado P~ l.l certifications or phase II EPA certification? Yes ... ........ No ;.1/)1 ... . 3 15. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the IRC? ,.,-;;1 rv Yes No t.-•#..7· 16. Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements comply with the requirements of the IRC? Yes ~JJ. ti.A, 17. Does the plan include a window schedule or other verification that windows provide natural light and ventila)i!:wjq.r all habitable rooms? Yes /. '}I.Jl. 18. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specifY safety glazin~Jb;se areas? Yes ~'V~ No ____________ _ 19. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the pi~~ M ~~~ II-A'f~S12- Yes • ·w../-.ov~<~ li.M ,...._. 20. Do you understand that if you are building on a parcel of land created by the exemption process or the subdiv~g p,rocess, are building plans in compliance with all plat notes and/or c~venants?, Yes 1/)JJJ. -n~ 1!!7.-11.-'fZMN fbz.e.>/, t!otv"f'TUJL l!tM?M~ 21. Do you understand that if you belong to a Homeowners Association (f:!OA), it is your responsibility to obtain written permission from the association, if required by that association, prior to submitting an application for a building permit? The building permit application will be accepted without it, but you run the risk of the HOA bringing action to enforce the covenants, which can result in revocation of permit issued. Additionally, your Plan Review fee is not refundable if the plans have been reviewed by the Building Department prior to any action by the HOA that requires either revoc~~raJ~bstantial modification of the plans. Yes v .4 22. Will this b~ ?Jlly residenti!] ?<:tjll'e on the parcel? . . Yes~ N6_t'~ lfno-Explam._-"'-5'--'-kP"'-'---- 23. Have two~ 9qjpplete sets of construction drawings been submitted with the application? Yes /. ')rlt.{}.. 24. Do you u~t,a@ that the minimum dimension a home can be on a lot is 20ft. wide and 20ft. long? Yes 1-'WcZ!. 4 25. Have you designed or had this plan designed while considering building and other construction code require~~faJ Yes t/WI#· 26. Do your plans comply with all zoning rules and regulations in the County related to your properties zonedi~?a/ Yes z VI~ • 27. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by the~fwld County Building Department? Yes i/llk1, 28. Do you understand that approval for design and/or construction changes are required prior to the appl.ic~lhese changes? Yes . , ------- 29. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application submittal and that you will be required to pay the "Permit Fee" as well as any "Road I!JJP!}GU' or "Septic System" fees required, at the time you pick up your building permit? Yes '!. 'f/,J. 30. Are you aware that you must call in for an inspection by 3:30 the business day before the requested inspection in order to receive it the following business day? Inspections will be made from 7:30a.m. to 3:30p.m. Monday through Friday. Inspections are to be called in to38~9~ Yes ,.'}ldl· No. _____ _ 31. Are you aware that requesting inspections on work that is not ready or not accessible will result in a $50.~0 !SJ:'in§pec 'o ee? Yes'/~ , -·-·--------------- 32. Are you aware that you are required to call for all inspections required under the IRC including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of the buildi~ /! 11 Yes 1~ · W ';:jJ. 33. Are you aware that the Permit Application must be signed by the Owner or a written authority being given ~n yent and that the party responsible for the project must comply with the IRC? Yes ·i/W'; 5 34. Do you understand that you will be required to him. a State of Colorado Licensed Electrician and Plumber to perform installations and hookups, unless you as the homeowner are performi~ WQik? The license number of the person performing the work will be required at time of applic~ jn~pection. Yes t 'W..:fl. 35. Are you aware, that on the front of the Building Permit Application you will need to fill in the Parcel/Schedule Number for the lot you are applying for this permit on prior to submittal of a buildi~~rwit application? Your attention in this is appreciated. Yes ,, 'f/;.,7, -- 36. Do you know that the local fire district may require you to submit plans for their review of fire safety issues~/ q/ Yes t :fi.,l. 1'/lf..(please check with the building department about this requirement) 37. Do you understand that if you are planning on doing any excavating or grading to the property prior to issuance ot,a building permit that you will be required to obtain a grading permit? Yes -;1i~JJ. 1 a: ~ · ' 38. Are you aware that if you will be connecting to a public water and/or sewer system, that the tap fees have to be paid and the connections inspected by the service provider prior to the issuance of a Certif~ o;t; Occupancy? Yes ,,'J./.Jl I hereby acknowledge that I have read, nnderstand and answered these questions to the best of my ability. /£J_y~ Signature of Owner Date Phone: q7-o 9f:/l 2'33(p (days); _1:_£5::....:_'/--='3:....:5=--1_3 ___ ,( evenings) Project Name: __ G_"f2..e!:y.,{I_;____C_--=::J'-'t-f.o'-'--'"P _____________ _ Project Address: t:H/Bo 6 PLAN REVIEW CHECKLIST Applicant C{ fle_ep e_ Date 3 • :?-7 -~ Building ~gineered Foundation ._____...Driveway Permit r;;x., ,{-1 _Jsurveyed Site Plan -4-septic Permit and Setbacks -4-Grade/Topography 30% Attach Residential Plan Review List ~inimum Application Questionnaire #.-Subdivision Plat Notes #Fire Department Review ~Valuation Determination/Fees v' Red Line Plans/Stamps/Sticker 4-Attach Conditions ~Application Signed ~Plan Reviewer To Sign Application ---LL'.rarcel/Schedule No. A 40# Snowload Letter-Manf. Hms. J Soils Report GENERAL NOTES: Planning/Zoning _JProperty Line Setbacks -(,.L30ft Stream Setbacks ~loodPlain 0uilding Height VZoning Sign-off V Road Impact Fees UHOAIDRC Approval !:!"<Jade/Topography 40% --~_Phlanning Issues *Subdivision Plat Notes ' No. 10882 Assessor's Parcel No. 2123-302-00-144 Date 4/1/2008 BUILDING PERMIT CARD Job Address 0480 elk run rd. New Castle Owner Greene. Thad & Denise Address 0480 Elk run rd, N'castle Phone # 984-2a3s Contractor Owner Address same Phone # 984-3813 Setbacks: Front Rear RH LH Zoning ____ _ garage/storage Soi Is Test ---::;---::;:;:-=----=-___,=--,__,. Footing 4--zz..~ o.?; q-2&{ Foundation £·6· tJ3" ;/:7J.('l.. Grout ___ ~~------------- Underground Plumbing "7\. 4- Rough Plumbing -rv- Framing /1--( 1-ofS' Ah'Vf Insulation ------------ Roofing------------ Drywall -----=--=------- Gas Piping ~ INSPECTIONS NOTES ·Weatherproofing ___________ _ Mechanical ____________ _ Electrical Rough (State) ~ Electrical );.inal (State), __ 7f-o~::::..i.~~~=-~~­Finai/;2~/I~RS' /Checklist Cof!!Pieted? ~1\. . Certificate Occupancy # ...:4?=.._~\_,'::)=!...::::0:::..______,,---:-=:c--- Date I >S.I.Ae::P I z· Z.Z.·c::e Septic System# ___________ _ Date ------------Final ___________ _ Other ___________________ ___ (continue on back) \ -- --, T ...._ _ _.... ___ ~~-----------~ '~~·:;~; :; • •b• ·,· .~.. • BUILDI~G PERMIT GARFIELD COUNTY, COLORADO /.~1,]-(Yf!i$ ' . I A @>84B >' ---' _, Date Issued .... £. ••• ··········-·····Zoned Area .•..•.•.•..•..•...............• Perm1t No .....•• \.!. •. iJ.&!.A ........ , , 'i AGREEMENT ;J:; - :, ( '-:'-:\ In consideration of the issuance of this permit, the appli~ant hereby agrees to comply with all,:;.::;;:'_] :,. : laws and regulations related to the zoning, location; construction and erection of the proposed_-:· __ ,- structure for which this permit is granted, and further agrees that if the above said regulations _ ::_-;;, are not fully complied with in the zoning, location, erection and construction of the above .< _: : described structure, the permit may then be revoked by notice from the County Building Inspector and IMMEDI?-TEL Y BECOME NULL AND VOID. -• _ , -· ---, use Gur~-re-PPJP -. · •: Address or Legal Description ri/&'o £if< RM lfod i\Jev Cf:Sfk_. Owner ~ -;Tia/f /JeJ/Jse-Contra~tor tJWAier ,,: .. ,., .. ,, •'v< ,; \ Setbacks Front Side Side Rear This Card Must Be Posted So It is Plainly Visible From Tbe Street Until Final Inspection. INSPECTION RECORD Footing Lj-:;. z -t:>:?> (/U). Driveway Foundation S~C,.-oS tfJi> Underground Plumbing /{) f} Insulation ,1/IJ Rough Plumbing Alii Drywall /{/f! Chimney & Vent AI J1. /1() !lev. Gas,Pipiog AIIJ Final /1-•11-1>8 ~ ~~~~--~~------~~~~~~--------~: "f1 0 S:Je<.. . Septic Final 7Ja- Framing 12.-\7. at.. Notes: (To include Roof in place arUJ Windows and Doors installed). ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING- WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND. THIS PERMIT IS NOT TRANSFERABLE APPROVED ,_._,_.. ;-., . ~·; . ..... , .. O'J.-. ·-<0 I I I I I I I I I I I I I I I I I I I I I I Parcel Detail Page 1 of3 Garfield County Assessor/Treasurer Parcel Detail Information Asse;,sor/Treasurer l'mp~B~arch I Ass<;ssor Subset Que!:)' I Assessor SaleJ> Search Clerk & Recorder_Reception Search P<rrcel Detail I Value Detail I Sales Detail I ResidentiaVCommerci!'ll Improvement Detail Land _I)etail I Photographs I Tax Area II Account Number II Parcel Number II 2007 Mill Levy I I 013 II R130374 II 212330200144 II 39.877 I Owner Name and Mailing Address !GREENE, THAD W. & DENISE J. 10480 ELK RUN ROAD INEW CASTLE, co 81647-9659 Assessor's Parcel Description (Not to be used as a legal description) iSECT,TWN,RNG:30-5-90 DESC: A TRIN !LOTS I & 2. PRE:Rl30297 BK:0958 IPG:0279 BK:0766 PG:0307 BK:0959 IPG:0722 Location I I I I I I I I Physical Address: 11480 ELK RUN RD NEW CASTLEj I Subdivision: I I Land Acres: jj22.123 I I Land Sq Ft: llo I Section II Township II Range I I 30 II 5 II 90 I 2007 Property Tax Valuation Information http://www.garcoact.com/assessor/parcel.asp?Parce!Number=212330200144 3/1112008 Parcel Detail II Actual Value II Assessed Value I I Land: II 200,00011 I Improvements: II 381,81011 I Total: Jl 581,81011 I IP============S=a=le~D=a=te~:l _I Sale Price: I Basic Building Characteristics Number of Residential 1 Buildings: Number of Commllnd 0 Buildings: I Residential Building Occurrence 1 Characteristics I TOTAL HEATED AREA: 113,024 I ABSTRACT CODE·IISINGLE F AM.RES- • IMPROVEMTS I ARCHITECTURAL STYLE: 112-STORY I EXTERIOR wALL: IIFR STUCCO I EXTERIOR wALL: IIBRICK VEN ROOF COVER: I!COMP SHNGL ROOF STRUCTURE: IIGABLE INTERIOR WALL: jjDRYWALL FLOOR: IIHARD TILE FLOOR: i!CARPET I HEATING FUEL: IiGAS I HEATING TYPE: IIHT WTR RAD I STORIES: I! STORIES 2.0 I BATHS: 113 I ROOMS:j 7 I UNITS: I• I BEDROOMS: 14 I YEAR BUILT: 111996 Tax Information 15,9201 30,3901 46,3101 I I I I I I I I I I I I I I I \1 Tax Year II Transaction Type II Amount 1\ http://www.garcoact.com/assessor/parcel.asp?ParcelNumber=212330200 144 Page 2 of3 3/1112008 Parcel Detail I 2007 II Tax Payment: Whole II ($1 ,846. 72)1 2007 II Tax Amount II $1,846.721 2006 II Tax Payment: Second Half II ($753.62)1 2006 II Tax Payment: First Half II ($753.62)1 2006 II Tax Amount II $1,507.241 2005 II Tax Payment: Whole II ($1,507.60)1 I 2005 II Tax Amount II $1,507.601 2004 II Tax Payment: Whole II ($1,597.54)1 2004 II Tax Amount II $1,597.541 2003 II Tax Payment: Whole II ($1,794.50)1 2003 II Tax Amount II $1,794.501 I 2002 II Tax Payment: Whole II ($1,742.00)1 I 2002 II Tax Amount II $1,742.001 2001 II Tax Payment: Whole II ($1,731.58)1 2001 II Tax Amount II $1,731.581 2000 II Tax Payment: Whole II ($1,553.86)1 2000 II Tax Amount II $1,553.861 1999 II Tax Payment: Whole II ($1,545.60)1 1999 II Tax Amount II $1,545.601 IQ12 ofPag~ Assessor. Database Search Options I Tre.f\surer Database Search Options Clerk & Recorder Databf!s~.Sef\rch Ontions G:fiffieldCmmty_Home .. Page Page 3 of3 ·--------------------------------------------------------------------------- The Garfield County Assessor and Treasurer's Offices make every effort to collect and maintain accurate data. However, Good Turns Software and the Garfield County Assessor and Treasurer's Offices are unable to warrant any of the information herein contained. Copyright © 2005 -2008 Good Turns Software. All Rights Reserved. Database & Web Design by Good Turns Software. http://www.garcoact.com/ assessor/parcel.asp ?ParcelN urnber=2123 3 0200144 3/1112008