Loading...
HomeMy WebLinkAboutApplication-PermitJim Wilson From: Sent: To: Subject: Shawn Wallace [tpishawn@earthlink.net] Friday, April 30, 2010 9:40AM Jim Wilson TPI -Brune Permit Jim, I spoke with my boss Chris McCallum about the open Brune permit. He said that the project is being litigated and that TPI needs to "stay out" of the permit issue, at least presently. Looks like Brune applied for the permit as applicant and TPI is listed as contractor, so it's mostly up to Brune. So if you could, TPI would like to leave it as is for now. Thank you. Shawn Wallace TPIIndustrial, Inc. tpishawn@earthlink.net (970) 243-4642 Fax: (970) 242-5330 _____ Information from ESET NOD32 Antivirus, version of virus signature database 5073 (20100429) The message was checked by ESET NOD32 Antivirus. http://www.eset.com 1 :@ Garfield County I ~~'--~-~~-.· . . . -. . ' -· ... ~---·-... -'· ···~ . . . . ..... . Vendor Name TPI INDUSTRIAL, INC. Remittance Address 2471 RIVER SIDE PARKWAY #A GRAND JUNCT ION CO 81505 Invoice Vendor Invoice Date Nwnber Fund 3/9/2011 03092011 100 Vendor Number 6295 Dept Sub Dept Account 17 070 3400 Prepared By: BECKY WHEELERSBURG Purchase Order Number If Purchase Order is complete checkbox: I:J Project # (if Line Item applicable) (64 Characters or Less) BUILDING REVENUE ACCOUNT Special Instructions For Warrant TH I S IS A REFUND OF BUILDING PERMIT FEES Invoi ce Brief Description Dollar (64 Characters or Less) Amount & SEPTIC PERMIT FEES-BP-10938 & SP- 4448 $4,570.25 Total $ 4,570.25 By signing below, I certify that all items and/ or services have been received, inspected, aild accepted; and that this amount is correc t and proper for paymen t. Department Head Approval: DATE: __ ....:M::.::a=.:.r.=ch:..:...=25=...,-=2:..::0..:...11.:... TPIINDUSTRI AL, INC. M emo . TO : Becky Wheelersburg FROM: JulieT CC: 1 vENDOR#: ~o ~<jo I ACCOUNT#:\00-\1 ' 0~10-3 '1 00 l ACCOUNT NAME :b ~~ ~ DATE : 3/9/2011 RE: (Watermark , LLC I BP -1 0938 & SP-4448) APPROVAL BY ANDY SCHWALLER: Y ES NO REASON FOR REFUND: · Jim, W got an emai l (see file to view email), as a response to us sending First Notification of expire d permit (letter). Basically it's say in g that this Project (building permit) is being litigated s o at this point TPI (contractor) would like to close the project. AMOUNT OF REFUND: Building Permit: $4,497.25 Septic Permit: $7 3.00 Total Refund : $4570:25 THE REFUND SHOULD BE MAILED TO: NAME: TPI Industrial, Inc Attn : Shawn Wallace MAILING ADDRESS: 2471 River Side Parkway, #A Grand Junction , CO 81505 Date: May 6, 2010 To: Watermark, LLC 8 Antelope Drive St. Peters, MO 63376 Dear Permit Holder, Please refer to your building permit number Garfield County BUILDING & PLANNING DEPARTMENT 10938 , issued 5/20/2008 A routine review of our open building permits indicates that we have not received a request for an inspection on this permit since issued Please be advised that building permits expire, per Uniform Building Code, section 106.4.4 or lnemational Code Sections 105.5 "Every permit issued by the building official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the buliding or work authorized by such permit is suspended or abandoned at any time after the work has commenced for a period of 180 days. Before such work can be recommenced, a new permit shall first be obtained to do so, and the fee therefore shall be one half the amount required for a new permit for such work, provided no changes have been made or will be made in the oritinal plans and specifications for such work, and provided further that such suspension or abandonement has not exceeded one year. In order to renew action or a permit after expiration, the permittee shall pay a new full permit fee." Please contact this office at your very earliest convenience, in writing, to advise us about the status of your permitted work. If you have not responded within thirty (30) days from the receipt of this notice the permit will be closed and a permanent notation will be placed in the property records at the County Clerk & recorders office that indicates that the work permitted per Colorado Revised Statues 30-28-205 & 210, was not inspected, is not approved and the building or area is illegal to occupy and is subject to legal abatement action or other option available by law. Thank you for your cooperation. Sincerely, ~ aP~ Jim Wilson Building Inspector 108 Eighth Street, Suite 40 I o Glenwood Springs, CO 8I60 I (970) 945-82I2 o (970) 285-7972 o Fax: (970) 384-3470 I Garfield County Building & Planning Department 108 8th Street, Suite #401 Glenwood Springs, Co. 81601 Office:970-945-8212 Fax: 970-384-3470 Inspection Line: 970-384-5003 Building Permit No. /0 i 3g Parcel No: 2181-054-00-249 Locality: Rippy Exemption, Tract 2 Job Address: 381§0_giyer-_F'o_ntag_erd, Nev;Castle Use of Building: 2 steel buildingcs_--"w~ar-=-e~ho:.::u_::_se=--------- Owner : Watermark LLC Contractor: TPI Industria/Inc Fees: Plan Check: $ 2,923.21 Septic: $ 73.00 ---------- Bldg Permit: $ 4,497.25 Other Fees: ----------- Total Fees: $ 7,493.46 Clerk: cr:. ~,_;t::: Date: 5/ r}_() 7 (leon f{ 7 I I To: Ju, <;~,ge 2 of 2 2009-04-23 20:43:22 (GMT) 1 ~314-584~ 7080 From: John Brune A11rH 23, 2009 Tu:Grutidd County Huildrng Divisiun Illi: 38150 River i"rootage Rd. New Castle, CO W arrcn lndu.stries bas the permission of John Brune i>> undertake the wurk.Ji)r the septic system 11t ihe abovernenl.ioncd property. IF tht-...e arc any questions rc>garding this job, ple11sc do not hesitate to comm-1. me at 114-973-56HL IS OS 2 3 4 5 6 7 g ? Describe Wotll.: ~{d. LO Class of Work: aCommunit 12 $ I.<\ M NOTTCF. ~ '·Thi~'llflllli&.:lltiun fi>r 11 Building l'crmltll\U.It be alj:J1Cld l>y th'c OWuL'r of th e properly, dc&."rilxd ubove. M uu' Bulh oril>N oge'nt. ·1 f lht sianlllU(ll below Is n01 rhnr of the 0WIIet, lliCpllfDIC I<> tiel nfiUJ.IhQI'ity, tiuoCld by tlui<.hYUV, ruust: be provided wi~ l(o is 't\pj~icalion. l.s:nl Aqnt, A lluUwo'i 'Pmnil """"'be ~ucd wi th<.out proofoF'Ic:g"'·'and o.Jo.tuoro aceo>slu &he proJ>Ut)'l i ~< purp<»et ofill.'lpccliOIU by lbo Buildi~ Popartmont. Other J>irmitc. t-.Mtij~o JqllltOle penni!~ l'tiiiY l>~ n:quir~'d : (!} l?t•lo .I:Joc:triGlll Penni I, (2) Cn~~r~t)· ISDS Ponnil, (J) •nllthcr ·pcrnJlt reqtdn:d for usc on the proyerty ldcotlft<'d above. e.g. Stole or · CuunJy Hlgl>wey/ Rnad ""ccu u:.:s SIJII~ Woiuewnter Disctws~ Ptnnit. \'uld l'unoli •. A Building ~cmdt bca,mCll liuU nnd voidifthc work aulhorlicd is notcommrnced within l80 clu)'s of the chile ofisall4n~ lUld if1Vnr1; i~ SUSJ)C'rlded•.w·abondoucd tbr a pcriud of 1 HO dn)•l oJkr i:onuue.acenu:ot · . . C.ER'FffiCA'llON . I l~cn:by certifY !hat lliWo rt:a£1 thiJ Ap11lica.lioo1 JUJd lhliflhc itlfonmliou contai11cd ~·is true and cotre.."'. l1wdo-sJ81Jd tballh~ Buildl!J8 Ocpamncnt o.:apls the "pplicatioo, bloog with th~ pl.,s 1Wd spocili~atiWIS ond othCC".dllll subrbill~ by, ma or ou my bi:ll.lll.f (subo:Utllils), blued UJl\lll .my ccr)ificntiou os 11> n.:curocy. Asswnlnl! completeness of the subwli~ aud 11pprovnl oflhis Applicnlioll'; A fhiildin~ l 'cmiit will be is~"'led gro~ting permiuioo ~me, ;~a Owmr. 10 conSini<;llhe $1ttlclurc{~) 1.1\<l f..cllilie$ do;Wilc.l ou the submlrtals reviewed by the Bulldlog Department. · 111 couslilcctlllon ortbe lssunncc orllle o 'uildlllg Pcnuli. 1 ~are;; tbtlt raurl my ngcms will comply wllll provbloas or llll)' rc<~eml;a~atc ut luo:nllaw rt~ulmlng the wolrir.' IUld 1hc Clarllcld \.ntlltl)' Building Code, ISPS regulations and opplicablo hutd tl5c rej!Ulnlions (C'.ounty.Ro,&ul:llioq(J)). 111111.:nuwlc<lgo thtlt I he BuiiJlug P<:rmit may be IU!j)Qided or revoked. upon oori~ frnmrhb Coomy, if the low ion. constructi(m or tUC off!le !ll:tUdulc(s) end focilily(ics), U=II>C<luhuva, lite uOI In cutnpljant:c with C<Jw•ty ~tliDl i <>n (s) Of MY Olhtt llpf>lil2ble law. l hcrcb)r.s~t pem1iniDn.(o the Building Deportment tn enter I he pmpcrty, ~c-rllxd 4bove, 111 Uupx:lllo~ wurk . I f1.11thcr lieknowlcd&e tliAI tl•o hsu&.<~U uf the Bui14iog J>ctmit docs oot prC\"COt tl\1: Building Ollicial ftooi: (I) roquiriog tho e«rTCCiiou o( cmn in tho ~ubmi tluls, it' any. iliscuo/crcd afier i~sumu:o: ur (2) stoppin& COOSiru~iioo.or UK oftbe Sltu~;tunl(') or ~ility(ies) if. such Is in violation o(CoWll),.~gularlon(t) or any· other tq>pllcable l..w . Review oflhl~ Appli cnrion. including ~ubmittal~. M!l iPSpa;tions oflho "mk hy lha B'uildint; OeiWfmcnl dro mil e<mstitutG •n ~nnce uf rcspunsil!iUty ot liobilily by the County oferiors, omi,ions •V cli.f=PMcic:o. As thu 0 • I oclmowlo.l~c thi\II'Cipu.Ui hi lity ror co.mplilli•cc wit h l'tdcn&l , 6lntc 11nd ltlellll~ws uud COIUi ty'R.i:&lll&lil)tU resr wltl\ rue nnd m)' lllllhNi.u.d ns.ents, including witltcuu limirtllju" ruy =hit eel · , w11inoer WJdl t>r; loul!dcr. J HEK.GBY AC:KNOW ' R 'rnAT 1 HAVI! ' AND UNDERSTA!'-'0 TI-lE NOTICE k C~RTrFJCA TION ABOVE: STAFF USE ONLY Adjusted Valuation : ~ }1Jan Check F ee: d-1&3 '2.\ Maou homl! Fcc: Fees !'aid: 4-1+ . rtf,.Qb Ruluncc nuc: 5% 11 4 ~ Setbacks: OCC Group: ConlltTyp~: :U:B 8LDGDEPT: PLNG llf:PT: L -'3o -o DATE A DAT£ ~cr··~ ~~?'~ ~ex-~~r-/P_}p cdux-vc·~V'~_ The.. -pern1t+ ~r-~fl\ tsYL-GV\8~ -f:x{i/di~ .. czk ~lt50 "P:_~uex-ttc~OP-y"-~d c /Jeo_x:ci5>'f{e_ ~Vlc./Claf'_cl t:s a_ c:ize~ ~ -f?~e T~e{l/'v[i f- ~~ O-Vt o_dt'-+Z6Hc~ flO~ p2-if~, f('('~~ ~~ ·1c:> ~Zte. c~rvw &/! -/he c!ter:d::... a"r evtL)eJ O(-X!--, -rt~~\ J11Zie. l::vt~ l ?b-nt~J.ev­ T[==>( 1ndu$fr2o-1 1 fLJLc.." 97GJ-?Bh -c.;Lf-ty:f- The following items are required by Garfield County for a final Inspection: l) A final Electrical Inspection from the Colorado State E!ectrica!Jnspector. 2) Permanent address assigned by Garfield County Building Department and posted at the structure and where readily visible from access road. 3) A finished roof; a lockable building; completed exterior siding; exterior doors an9 windows installed; a complete kitchen with cabinets, sink with hot&, cold running water, non-absorbent kitchen floor covering, conntei" tops and finished walls, ready for stove and refrigerator; all necessary· plumbing. 4) All bathrooms must be complete, with washbowl, tub or shower, toilet, hot and cold running water, non-absorbent floors, walls finished, and privacy door. 5) Steps over three (3) risers, outside or inside must be musthave handrails. Balconies and decks over 30" high must be constructed tn a!llBC and IRC requirements including guardrails. 6) Outside grading completed so that water slopes away from the building; 7) Exceptions to the outside steps, decks, grading may be tnade upon the demonstration of extenuating circumstances., i.e. weather. Under such circumstances A Certificate of Occupancy rnay be issued conditionally. 8) A final inspection sign off by the Garfield County Road & Bridge Department for driveway installation, where applicable; as well as any final sign off by the Fire District, amVor Siate Agencies where applicable. A CERTIFICATE OF OCCUPANCY (C.O.) WILL NOTBEJSSUED UNTIL ALL THE ABOVE .ITEMS HAVE BEEN COMPLETED. A C.O. MAY TAKE UP TO 5 BUSINESS DAYS TO BE PROCESSED AND ISSUED. OWNER CANNOT OCCUPY OR USE DWELLING UNTIL A C.O. IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A CO, WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. I understand and agree to abide by the above conditions for occupancy, use and the issuance of a C.O. for the building identified in the Building Permit. DATE Bapplicationd cember2007 VALUATION FEE DETERMINATION Applicant Address Date ..,:W.:,.a:::t.::;erm"='ar"'k"--:::-----,::-:-------Subdivision 38150 River Frontage Rd. Lot/Block -:;4.:;;/3~0';;/2:.;0:;:0';;-8"'-'====------Contractor Finished (Livable Area): Main Upper Lower Other Total Basement: Unfinished Square Feet Valuation Conversion ofUnfinished to Finished Total Valuation Garage: Valuation Crawl Space Valuation Decks/ Patios Covered Open Valuation Type of Construction: Occupancy: S-2 S-2 Valuation Total Valuation sf sf sf sf X $74.68 0 sf sf X $41.00 sf X $33.68 sf X $18.00 sf X $9.00 sf X sf X Commercial 9600 sf X 9600 sf X sf X sf X sf X sf X $24.00 $12.00 $39.88 $39.88 Adair Rippy Exemp Tract 2 TPI industrial 0.00 0.00 0.00 0.00 0.00 -3'1? J.. J 'ilL/ 'I?. ''V ~ 3 \f ~ I "';'f '\?. ,"'> 765,696.00 765,696.00 GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS FOR CONSTRUCTION OF COMMERCIAL OR MULTI-FAMILY RESIDENTIAL BUILDINGS Including NEW CONSTRUCTION ADDITIONS ALTERATIONS And MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. When reviewing a plan and it's discovered that required information has not been provided by the applicant, this will result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor shall be required to provide this information before the plan review can proceed. Other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. Any project with more than ten (10) occupants requires the plans to be sealed by a Colorado Registered Design Professional. To provide for a more understandable plan and in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following checklist prior to and during design. Plans to be included for a Building Permit must be on draft paper at least 18"x 24"" and drawn to scale. Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks, balcony steps, hand rails and guard rails, windows and doors, including the finish grade and original grade I line. A section showing in detail, from the bottom of the footing to the top of the roof, including re-bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house-rap, (which is required), siding or any approved building material. Engineered foundations may be required. Check with the Building Department. A window schedule. A door schedule. A floor framing plan, a roofing framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. windspeed, wind exposure B or C, and a 36 inch frost depth. All sheets need to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be incompliance with the 2003 IBC, IPC, IMC, IFGC, and IFC. Applicants are required to indicate appropriately and to submit completed checklist at time of application for a permit: 1. Is a site plan included that identifies the location of the proposed structure, additions or other buildings, setback easements, and utility easements showing distances to the property lines from each comer of the proposed structure prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Slopes of 30% or more on properties must be show on site plan. (NOTE: Section 106.2) Any site plan for the placement of any portion of a structure within 50 ft. of a property line and not within a previously surveyed building envelope on a subdivision final plat shall be prepared by a licensed surveyor and have the surveyors signature and professional stamp on the drawing. Any structure to be built within a building envelope of a lot shown on a recorded subdivision plat, shall include a copy of the building envelope as it is shown on the final plat with the proposed structure located within the envelope. . Yes <::::,<"e."-4----t\...o.-'So' 5;:..-._ ~""'<',....~ \,"'- 2. Does the site plan when applicable include the location of the I.S.D.S. (Individual Sewage Disposal System) and distances to the property lines, wells (on subject property and adjacent properties), streams or water courses? This information must be certified by a licensed surveyor with their signature and professional stamp on the design. Yes Not necessary for this project '/, 3. Does the site plan indicate the location and direction of the State, County or private road accessing the property? Yes___y,_ 4. Is the I.S.D.S. (Individual Sewage Disposal System) designed, stamped and signed by a Colorado Registered Engineer? Yes X Not necessary for this project. __ _ 2 5. Are the plans submitted for application review construction drawings and not drawings that are stamped or marked identifying them as "Not for construction, for permit issuance only", "Approval drawings only", "For permit issuance only" or similar language? Yes '1. Not necessary for this project __ _ 6. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the building code or per stamped engineered design? Yes----A-Not necessary for this project __ 7. If the building is a pre-engineered structure, is there a stamped, signed engineered foundation plan for this building? Yes__L Not necessary for this project __ 8. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and earth? Yes __ Not necessary for project____b_ 9. Do the plans indicate the size and location of the ventilation openings for the attic , roof joist spaces and soffits? Yes __ Not necessary for this project_____:6_ 10. Do the plans include design loads as required under the IBC or IRC for roof snowloads, (a minimum of 40 pounds per square foot in Garfield County)? Yes~ Not necessary for this project __ 11. Do the plans include design loads as required for floor loads under the lBC or IRC? Yes ---X.,_ Not necessary for this project __ 12 . Does the plan include a building section drawing indicating foundation, wall, floor , and roof construction? Yes~ Not necessary for this project __ 13. Is the win<;} speed and exposure design included in the plan? Yes~ Not necessary for this project __ 14. Does the building section drawing include size and spacing of floor joists, wall studs , ceiling joists, roof rafters or joists or trusses? Yes__j_ Not necessary for this project __ 3 15. Does the building section drawing or other detail include the method of positive connection of all columns and beams? Yes~ Not necessary for this project __ 16 . Does the elevation plan indicate the height of the building or proposed addition from the undisturbed grade to the midpoint between the ridge and eave of a gable or shed roof or the top of a flat roof? (Check applicable zone district for building height maximum) Yes~ Not necessary for this project __ 17. Does the plan include any stove or zero clearance firep lace planned for installat1on including make and model and Co lorado Phase ll certifications or Phase II EPA certification? Yes __ Not necessary for this project_L 18. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the IBC or IRC? Yes __ Not necessary for this project~ 19. Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements comply with the requirements of the IBC or IRC? Yes _x_ Not necessary for this project __ 20. Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable rooms? Yes __ Not necessary for this project~ 21. Do the plans indicate the location of g laz ing subject to human impact such as g lass doors , glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding g la ss doors; fixed glass panels ; shower doors and tub enclosures and specify safety glazing for these areas? Yes _L_ Not necessary for this project __ 22. Do the plans include a complete design for all mechanical systems planned for installation in this building? Yes __ No+-Not necessary for this project ~ 4 23. Have all areas in the building been accurately identified for the intended u se? (Occupancy as identified in the IBC Chapter 3) Yes-)!_ Not necessary for this project" __ _ 24. Does the plan indicate the quantity, form , use and storage of any hazardous materials that may be in us e in this building? r- Yes __ Not necessary for this project--X- 25. I s the location of all natural and liquid petroleum gas furnaces , boilers and water b eaters indicated on the plan? . ~ Yes __ Not necessary for this project1___ 26. Do the plans indicate the location and dimension of restroom facilities and if more than four employees and both sexes are employed, facilities for both sexes? Yes X Not necessary for this project __ • 27. Do the plans indicate that restrooms and access to the building are handicapped accessible? Yes~ Not necessary for this project __ 28. Have two (2) complete sets of construction drawings been submitted with the application? Yes~ 29. Have you de signe d or had this plan designed while considering building and other construction code requirements? Yes-----A- 30. Does th e plan accurately indicate what you intend to construct and what will receive a final inspection by the Garfield County Building Department? Yes __i::.,_ 31. Do your plans comply with all zoning rules and regulations in the County related to your zone district? For corner lots see supplemental section 5 .05.03 in the Garfield County Zoning Resolution for setbacks. Yes 'b.. 32. Do you understand that approval for design and/or construction changes are required prior to the implementation of these changes? Yes~ 5 33. Do you understand that the .Building Department will collect a "Plan Review" fee from you at the time of application and that you will be required to pay the "Permit" fee as well as any "Septic System" or "Road Impact" fees required, at the time you pick up your building permit? Yes~ 34. Are you aware that you are required to call for all inspections required under the IBC including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of the building? Yes_l:~-- 35. Are you aware that the Permit Application must be signed by the Owner or a written authority be given for an Agent and that the party responsible for the project must comply with the Uniform Codes? Yes ___:j,.__ 36. Are you aware that you must call in for an inspection by 3:30 the business day before the requested inspection in order to receive it the following business day? Inspections will be made between 7:30a.m. and 3:30p.m. Monday through Friday. Inspections are to be called in to 384-5003. Yes_l 37. Are you aware that requesting inspections on work that is not ready or not accessible will result in a $50.00 re-inspection fee? Yes_L 38. Are you aware that prior to submittal of a building permit application you are required to show proof of a legal and adequate access to the site? This may include (but is not limited to) proof of your right to use a private easement/right of way; a County Road and Bridge permit; a Colorado Dept. of Highway Permit including a Notice to Proceed; a permit from the federal government or any combination. You can contact the Road & Bridge Department at 625-8601. See Phone book for other agencies Yes~ 39. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups? The license number will be required at time of inspection. Yes___2S,_ 40. Are you aware, that on the front of the building permit application you will need to fill in the Parcel/ Schedule Number for the lot you are applying for this permit on prior to submittal of the building permit application? Your attention in this is appreciated. Yes _____'f,_ 41. Do you !mow that the local fire district may require you to submit plans for their review of fire safety issues? Yes___]<._,__ (Please check with the building department about this requirement) 6 42. Do you understand that if you are planning on doing any excavating or grading to the property prior to is suance of a building permit that you will be required to obtain a grading permit? Yes ____::b_ Not necessary for this project __ 43. Did an Architect seal the plans for your commercial project? State Law requires any commerc ial project with occupancy of more than 10 persons as per Section 1 004 of the IBC to prepare the plans and specifications for the project. Yes ~ Not Necessary for this project ____ _ I hereby acknowledge that I have read, understand, and answered these questions to the best of my ability. Signature Phone: '\\o :.l.~~c ... ~ll (days); _________ (evenings) Project Name: __ ~ __ ,.._'-'-_'IVL-__ ¥._..:....,.-=c"'~~'-'e..:o.:L.._~~------ Project Address: Note: On any of these questions you may be required to provide this information. If required information is not supplied, delays in issuing the permit are to be expected. Work may not proceed without the issuance of the permit. *If you have answered "Not necessary for this project" on any of the questions and it is determined by the Building Official that the information is necessary to review the application and plans to determine minimum compliance with the adopted codes, please expect the following : A. The application may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review. B . Delay in issuance of the permit. C. Delay in proceeding with construction. BpcommDec2007 7 PLAN REVIEW CHECKLIST Applicant '-" ;&=LtUL 1Vl¢l.t Date __ L ....... r _--...... '!>"'-CJ=:.._-_o_,Y'------ Building ~gineered Foundation ___lLI)riveway Permit O,v'o ~ ~urveyed Site Plan -if-Septic Permit and Setbacks ~Grade/Topography 30% ~ ~Attach Residential Plan Review List ~inimum Application Questionnaire ~Subdivision Plat Notes ~ire Department Review ~luation Determination/Fees ----URed Line Plans/Stamps/Sticker ~ttach Conditions V Application Signed l../"' Plan Reviewer To Sign Application ~arceVSchedule No . ~ Snowload Letter-Man£. Hms. Soils Report GENERAL NOTES: Planning/Zoning L/Property Line Setbacks ~Oft Stream Setbacks LFlood Plain dBuilding Height ~ning Sign-off Ji/L._Road Impact Fees J!j.__HOA/DRC Approval ~ade/Topography 40% ~Planning Issues ~bdivision Plat Notes HOUGLAND & ASSOCIATES CONSULTING ON WILDFIRE HAZARD MITIGATION, FffiE PROTECT ION AND BUILDING & FIRE CODES PHONE (970) 384-12 2 1 I FAX (970) 384-1331 17 GAMBA DRIVE, GLENWOOD SPRINGS, COLORADO 81601 April 27, 2008 Andy, BRUNE PROJECT 38150 River Frontage Road New Castle, Colorado In the Analysis that I have attached to each set of plans and provided for the folder I have indicated in bold notations and corrections. There are not many and some may only require clarification. As far as the valuation of the project I noted on the permit application the owner indicated a valuation of$1.9 M. I measured the buildings and they are each 9,3 08 sq. ft. measured inside the exterior walls . The last information I have on fees (Oct. I , 2004) indicate steel frame warehouses at $39.88 per square ft. is that what you are still using? Using this figure I come up with a valuation of $742,406.08 for both buildings. Also, both buildings are exactly the same except for their location on the property and their relation to the street, property line and other buildings. It looks like you may have figured the fees for only one building since they are the same. Let me know what you would like to do! Contact me if you have any comments or questions on these plans! Thanks, HOUGLAND & ASSOCIATES CONSULTING ON WILDFIRE HAZARD MITIGATION, FIRE PROTECTION AND BUILDING & FIRE CODES PHONE (970) 384-1221/ FAX (970) 384-133117 GAMBA DRIVE, GLENWOOD SPRINGS, COLORADO 81601 firesafe@sopris.net PLAN ANALYSIS Notations in bold may also indicate required corrections April 27, 2008 Project Name: Address: Designer: Brune Project, North and South Buildings 38150 River Frontage Road, New Castle, Colorado CCI Engineering 1129 24 Road Grand Junction, Colorado 81505 970 245-0577 Metal Building Engineer: B&C Steel PO Box 1099 Occupancy: Scottsbluff, Nebraska 69363-1099 308 632-6188 S-1 NOTE: If Materials other than those listed in Section 311.2 are stored or used in any of these shops it may change the Occupancy Group of the entire building and trigger other building and/or fire code requirements. I recommend that it be made clear to the Building Official and Fire Chief or Fire Marshal regarding what materials are to be used or stored in these buildings. Construction Type: V-B Report by: Note: The listing of Art Hougland code items listed in this report are not intended to be a complete all possible code requirements of the 2003 International Building Code. Portions of the material contained in this report are reproduced from the International Building Code published by the International Code Council Notice: The review of plans and specifications does not constitute an acceptance of any responsibility by Hougland & Associates for errors, omissions or discrepancies. The responsibility for these items and implementation during construction rests specifically with the architect, engineers, designers, builders and owner. Comments and notations are intended to be constructive and in support of the owners interest. FRONTAGE INCREASE: Perimeter of the entire building = 435 feet. Perimeter which fronts a public way or accessible open space Minimum width of public way or accessible open space = 39 Allowable area increased 38.45% for frontage increase. Sec. 506.2 NOTE: Limit in Section 506.2.1 used. 276 feet. FL NAME occ MAX FLR AREA ALLOWED RATIO STATUS ------------------------------------------------------------------- 1 Storage/Shop #1 S-1 ok 2243 12460 0.18 ok 1 Toilet Room #1 S-1 ok 50 12460 0.0 ok 1 Storage/Shop #2 S-1 ok 2267 12460 0.18 ok 1 Toilet Room #2 S-1 ok 50 12460 0.0 ok 1 Storage/Shop #3 S-1 ok 2267 12460 0.18 ok 1 Toilet Room #3 S-1 ok 50 12460 0.0 ok 1 Storage/Shop #4 S-1 ok 2243 12460 0.18 ok 1 Toilet Room #4 S-1 ok 50 12460 0.0 ok 1 WallsLPartitions S-1 ok 88 12460 0.01 ok TOTAL FOR FLOOR 9308 12460 0.75 ok BUILDING TOTAL 9308 12460 0.75 ok --Sec. 503, 504, 506 and Table 503 The actual height of this building is 24.0 feet. The maximum height of this building is 40.0 feet. --Table 503 PROPERTY DESCRIPTION FOR NORTH BUILDING: North Side has a public way. -Distance to public way = 85.0 ,width = 30.0 Exterior wall rating based on distance to center line of public way. --Sec. 702.1 FIRE SEPARATION DISTANCE East Side has building. -To building= 100.0 ,assumed property line 50.0 Exterior wall rating based on distance to assumed property line. --Sec. 704.3 and 702.1 FIRE SEPARATION DISTANCE South Side has building. -To building= 60.0 ,assumed property line 30.0 Exterior wall rating based on distance to assumed property line. --Sec. 704.3 and 702.1 FIRE SEPARATION DISTANCE West Side has a property line. -Distance to property line 50.0 PROPERTY DESCRIPTION FOR SOUTH BUILDING: North Side has building. -To building = 60.0 ,assumed property line 30.0 Exterior wall rating based on distance to assumed property line. --Sec. 704.3 and 702.1 FIRE SEPARATION DISTANCE East Side has building. -To building = 100.0 ,assumed property line 50.0 Exterior wall rating based on distance to assumed property line. --Sec. 704.3 and 702.1 FIRE SEPARATION DISTANCE South Side has a property line. -Distance to property line 150.0 West Side has a property line. -Distance to property line 50.0 NOTE: The following information is applicable to both the North and the South Buildings: EXTERIOR WALL FIRE RATINGS AND OPENING PROTECTION FOR BOTH BUILDINGS Sec. 602, Tables 601 and 602, and Sec. 704 NORTH EAST SOUTH WEST OCC BRG NON OPNG% BRG NON OPNG% BRG NON OPNG% BRG NON OPNG% WALL BRG UP/PR WALL BRG UP/PR WALL BRG UP/PR WALL BRG UP/PR S-1 0-hr 0-hr NL/NL 0-hr 0-hr NL/NL 0-hr 0-hr NL/NL 0-hr 0-hr NL/NL up/pr = Maximum percent of openings in the exterior wall. Table 704.8 NL =No fire protection requirements for openings. Note: Unlimited unprotected openings are allowed in walls not required to fire-resistant. --Table 704.8, Note: g. FIRE RESISTANCE RATINGS FOR BUILDING ELEMENTS --Table 601 ELEMENT Structural Frame Interior Bearing wall Interior non-bearing wall Floor/Ceiling Assembly Roof/Ceiling Assembly Stairs NOTES: None MATERIAL Any Any Any Any Any Any RATING 0 hour 0 hour 0 hour 0 hour 0 hour None NOTES OCCUPANCY SEPARATIONS Sec. 302.3.2 and Table 302.3.2 No occupancy separations required. SEPARATION OF INCIDENTAL USE AREAS --Table 302.1.1 Furnace rooms where any piece of equipment is over 400,000 BTU per hour input --1 hour Rooms with any boiler over 15 psi and 10 horsepower --1 hour Refrigerant machinery rooms --1 hour Incinerator rooms --2 hours NOTE: An automatic sprinkler system is required Storage rooms over 100 square feet --1 hour Note: This list covers only the most common uses. See Table 302.1.1 for a complete list. EXIT REQUIREMENTS: FL NAME 1 Storage/Shop #1 1 Toilet Room #1 1 Storage/Shop #2 1 Toilet Room #2 1 Storage/Shop #3 1 Toilet Room #3 1 Storage/Shop #4 1 Toilet Room #4 1 WallsLPartitions TOTAL FOR FLOOR AC AC AC AC NUMB occ 7 8 8 7 30 MIN MIN EXITS WIDTH 1 1.4 0.0 1 1.6 0.0 1 1.6 0.0 1 1.4 0.0 0.0 1 6.0 PANIC CORRIDOR DOOR HDWR RATING SWING No N/A N/R No N/l\ N/R No N/A N/R No N/A N/R No N/A N/R No N/A N/R No N/A N/R No N/A N/R No N/A N/R No N/A N/R NOTES 1 NOTE: Areas with 'AC' before the number of occupants is being treated an accessory use area. This area is only used persons who occupy the main areas of the building. The occupant load of this area is not included in the total occupant load for suites, floors, or the building. FOOTNOTES: l. One exit is based on compliance with Section 1018.2 #3 and Table 1018.2 NOTES FOR EXIT TABLE Door swing is based on Section 1008.1.2 Occupant load is based on Section 1004 and Table 1004.1.2 Exit width is in inches and based on Section 1005.1 & Table 1005.1 Width shown for all areas is based on other egress components. For the minimum width of doors, see Section 1008.1.1. BOLT LOCKS: Manually operated flush bolts and surface bolts are not permitted. --Sec. 1008.1.8.4 LOCKS AND LATCHES: Egress doors shall be readily openable from the egress side without the use of a key or any special knowledge or effort. --Sec. 1008.1.8 Locks and latches shall be permitted to prevent operation where any of the following exists: Exception 2: The main door or doors in Group S areas are permitted to be equipped with key operating locking devices from the egress side provided: 2.1 The locking device is readily distinguishable as locked. 2.2 A readily visible durable sign is posted on the egress ADDITIONAL DOORS: side stating: THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED If additional doors are provided for egress purposes, they shall conform to the requirements in Section 1008.1 LANDINGS AT DOORS: 1. There shall be a floor or landing on each side of a door. --Sec. 1008.1.4 2. Such floor or landing shall be at the same elevation on each side of the door. --Sec. 1008.1.4 3. The floor or landing shall not be more than 1/2 inch lower than the threshold. --Sec. 1008.1.6 4. Landings shall have a width not less than the width of the stairway or width of the doorway, whichever is the greater. Where a landing serves an occupant load of 50 or more, doors in any position shall not reduce the landing dimension to less than one half it required width. The minimum length in the direction of exit travel is 44 inches. --Sec. 1008.1.5 EXIT ACCESS TRAVEL DISTANCE: The maximum travel distance in Group Sl is 200 feet. --Table 1015.1 BUILDING ACCESSIBILITY 1. In addition to accessible entrances required by Sections 1105.1.1 through 1105.1.6, at least 50 percent of all public entrances shall be accessible. --Sec. 1105.1 2. At least one accessible entrance shall be provided to each tenant. --Sec. 1105.1.6 3. Where parking is provided, accessible parking spaces hall be provided in compliance with Table 1106.1 --Sec. 1106.1 4. Accessible routes shall coincide with or be located in the same area as a general circulation path. Where the circulation path is interior, the accessible route shall also be interior. --Sec. 1104.5 ROOFING REQUIREMENTS: 1. The roofing on this building is required to be Class C. --Table 1505.1 AUTOMATIC SPRINKLER SYSTEMS --Sec. 903 Openings are provided in each 50 feet on one exterior wall and there is no floor area more than 75 feet from an exterior opening, an automatic sprinkler system is NOT required. --Sec. 903.2.10.1 Openings have a minimum dimension of 30 inches. There is at least 20 sq. ft. of opening in every 50 lineal feet of wall or fraction thereof. --Sec. 903.2.10.1 STANDPIPE AND HOSE SYSTEMS --Sec. 905 A standpipe system is not required. Areas containing high piled combustible stock or rack storage in any occupancy group require smoke and heat vents. Design to comply with the International Fire Code. --Sec. 910.2.3 LIGHT AND VENTILATION 1. Every space intended for human occupancy shall be provided with natural light. The minimum net glazed area shall not be less than 8% of the floor area. --Sec. 1205.1 and 1205.2 Any room is permitted to be considered as a portion of an adjoining room where one half of the area of the common wall is open and unobstructed and provided not less than one tenth of the floor area or 25 square feet, whichever is greater. --Sec. 1205.2.1 Artificial light shall be provided that is adequate to provide an average illumination of 10 foot candles over the area of the room at a height of 30 inches above the floor. --Sec. 1205.3 2. Natural ventilation of an occupied space shall be through windows, doors, louvers or other openings to the outdoors. --Sec. 1203.4 The minimum openable area to the outdoors shall be 4 percent of the floor area. --Sec. 1203.4.1 Any room is permitted to be considered as a portion of an adjoining room where unobstructed openings are provided that have an area not less than 8% of the floor area of the interior room but no less than 25 square feet. --Sec. 1202.3.1.1 When openings are below grade, clear space measured perpendicular to the opening shall be one and one half times the depth of the opening. --Sec. 1203.4.1.2 PLUMBING AND MECHANICAL: No information was provided regarding any mechanical and/or space or water heating or plumbing in these buildings. All plumbing will require a plumbing permit from the County and all work must comply with the 2003 International Plumbing Code (IPC). All mechanical work will require a permit from the County and all heating and/or mechanical work must comply with the 2003 IPC or 2003 International Mechanical Code (IMC) . WALL AND CEILING FINISH: 1. Wall and ceiling finish materials are required to comply with Sec. 803.5 and Table 803.5. 2. Toilet room floors shall have a smooth, hard nonabsorbent surface that extends upward onto the walls at least 6 inches. --Sec. 1210.1 3. Walls within 2 feet of urinals and water closets shall have a smooth, hard nonabsorbent surface, to a height of 4 feet above the floor. --Sec. 1210.2 INSULATION NOTES: 1. Insulating materials shall have a flame-spread rating of no more than 25 and a smoke developed index of not more than 450. --Sec. 719.2 (concealed installation) and Sec. 719.3 (exposed installation) 2. Where such materials are installed in concealed spaces, the flame spread and smoke developed limitations do not apply to facings,coverings and layers of reflective foil that are installed behind and in substantial contact with the unexposed surface of the ceiling, wall or floor finish. Sec. 719.2.1 Foam plastic insulation is required to be protected. Sec. 2603 ACCESSIBLE FACILITIES: NOTE: Except as noted, section numbers listed below are from ICC/ANSI A117.1-1998 TOILET FACILITIES: 1. A 60 inch diameter turning space or T-shaped space is required in the toilet room. --Sec. 603.2.1 and 304.3 Doors shall not swing into the clear floor space for any fixture. 603.2.3 See exception for rooms used for individual use. NOTE: It is not clear that this turning space has been provided in these Toilet rooms. Please provide information to the Building Official to verify compliance. Other accessibility items within the Toilet Rooms appear to comply as drawn on the plans. 2. Water closet shall be mounted adjacent to a side wall or partition. The distance from the side wall or partition to the centerline of the water closet shall be 16 to 18 in. Sec. 604.2 5. Grab bars shall have a circular cross section with a diameter of 1 1/4 inch minimum and 2 inches maximum, or shall provide equivalent grasp. --Sec. 609.2 The space between the wall and the grab bar shall be 1 1/2 inches. Sec. 609.3 Grab bars shall be mounted in a horizontal position 33 inches minimum and 36 inches maximum above the floor. --Sec. 609.4 a. Side wall grab bars are required to start within 12 inches of the back wall and extend to 54 inches from the back wall. (The minimum length of the bar is 42 in) --Sec. 604.5.1 b. The rear bar shall be 24 in long minimum 1 centered on the water closet. Where space permits, the bar shall be 36 in long minimum 1 with the additional length provided on the transfer side. --Sec. 604.5.2 6. The top of the water closet seats shall be 17 to 19 inches above the floor. --Sec. 604.4 7. Accessible urinals shall be of the stall type or wall hung with the rim at 17 inches maximum above the floor. Sec. 605.2 8. Accessible lavatories shall be mounted with the rim 34 inches maximum above the floor. --Sec. 606.3 9. Sinks shall be 6 1/2 inches deep maximum. --Sec. 606.5 10. Water supply and drain pipes under lavatories shall be insulated or otherwise treated to protect against contact. --Sec. 606.6 11. Mirrors shall be mounted with the bottom edge of the reflecting surface 40 inches maximum above the floor. --Sec. 603.3 GLAZING REQUIREMENTS All glazing in hazardous locations is required to be of safety glazing material. --Sec. 2406.1 Locations: Sec. 2406.3 1. Glazing in swinging doors. 2. Glazing in fixed or operable panels adjacent to a door where the nearest exposed edge of the glazing is within a 24-inch arc of either vertical edge of the door in a closed position and where the bottom exposed edge of the glazing is less than 60 inches above the walking surface. NOTE: Sheet A2 and the Engineered Building plans do not indicate any reference to safety glazing in the doors or within 24-inches of the doors as required by Sec. 2406. STRUCTURAl.: Foundation Design: The structural sheets appear to comply with design requirements of the 2003 IBC however, the general notes do not indicate that the design is directed to compliance with the 2003 IBC. Engineered Steel Building: The steel building plans specify design to the 2003 IBC and the design criteria complies with the 2003 IBC. However, the plans submitted are not stamped by an engineered registered in the State of Colorado. Stamped plans acceptable to the Building Official should be provided. GRADING: Only one Grading Plan was submitted with this application and that has been attached to the OFFICE set of plans. Another set should be provided to the building Department for attachment to the FIELD set of plans. Parcel Detail Page 1 of 4 Garfield County Assessor/Treasurer Parcel Detail Information Assessor/Treasurer Property Sellorch I Assessor Subset Query I Asses~r_S-<lles Search Clerk &Re_GQideLR~<:e:Rtiq_I1_£e_llLch B!lsic Building Characteristics I Taxinformatio!l Parcel Detail I Value Detail I Sales_Detail I Residential/Commercial Imnrovement Detail Land Detail I Photogranhs I Tax Area II Account Number II Parcel Number II 2007 Mill Levy I I 023 II R150230 II 218105400249 II 45.551 I Owner Name and Mailing Address !WATERMARK LLC 125 FOXBORO ROAD 1sT LOUIS, MO 63124 Assessor's Parcel Description (Not to be used as a legal description) ISECT,TWN,RNG:5-6-91 DESC: A TR IN IE114 OF SEC 5. AKA TRACT 2 RIPPY !EXEMPTION PRE:R150190 BK:0942 IPG:0838 BK:0942 PG:0739 BK:0942 IPG:0738 BK:0925 PG:0247 BK:0839 IPG:0171 BK:0430 PG:0073 BK:0360 IPG:0501 BK:0207 PG:0438 BK:1735 IPG:229 RECPT:684215 BK: 1735 PG:227 IRECPT:684214 BK:1735 PG:226 IRECPT:684213 BK:1735 PG:225 IRECPT:684212 BK:1598 PG:320 IRECPT:654545 BK:1461 PG:429 IRECPT:625720 BK:0945 PG:0424 IBK:0942 PG:0762 http://www.garcoact.com/assessor/parcel.asp?Parce1Number=2181 05400249 I I I I I I I I 4/14/2008 Parcel Detail Page 2 of 4 Location I Physical Address: 1138150 RIVER FRONTAGE RD NEW CASTLE! I Subdivision: I I Land Acres: 114.22 I Land Sq Ft: I 0 I Section II Township II Range I 5 II 6 II 91 I 2007 Property Tax Valuation Information II Actual Value II Assessed Value I I Land: II 1,654,41011 479,7801 I Improvements: II 965,o8oll 279,8701 I Total: II 2,619,49011 759,6501 Sale Date: 1110112/2005 Sale Price: 112,700,000 Basic Building Characteristics Number of Residential 0 Buildings: Number of Comm!Ind 3 Buildings: I Commercial/Industrial Building Occurrence 1 Characteristics I I TOTAL HEATED AREA: 110 I ABSTRACT CODE: llw AREHOUSE/STORAGE-IMPS.I I ARCHITECTURAL STYLE: IIWAREHOUSE I I EXTERIOR wALL: IIPREF AB MTL I ROOF COVER: IIPRO pANEL I ROOF STRUCTURE: IIGABLE I INTERIOR wALL: IIUNFINISHED FLOOR: IIcoN ON GRD HEATING FUEL: IlGAS I HEATING TYPE: IIUNIT HEATR I STORIES: IISTORIES 1.0 I II http:/ /www.garcoact.com/assessor/parcel.asp?ParcelNumber=2181 05400249 4114/2008 Parcel Detail I BATHS: 14 I UNITS: 14 I YEAR BUILT: 112004 I Tax Information Tax Year II Transaction Type II Amount I 2007 II Tax Payment: Second Half II ($17,301.40)1 2007 II Tax Payment: First Half II ($17,301.40)1 2007 II Tax Amount II $34,602.801 2006 Tax Payment: Whole II ($32,383.20)1 2006 Tax Amount I $32,383.201 2005 Tax Payment: Second Half ($2,005.31)1 2005 Tax Payment: First Half ($2,005.31)1 2005 I Tax Amount $4,010.621 2004 Tax Payment: Whole ($3,233.84)1 2004 Tax Amount $3,233.841 2003 Tax Payment: Whole ($3,596.72)1 2003 I Tax Amount I $3,596.721 2002 Tax Payment: Whole ($3, 152.36)1 2002 Tax Amount $3,152.361 2001 Tax Payment: Whole ($3,135.48)1 2001 Tax Amount $3,135.481 2000 I Tax Payment: Whole ($2,818.86)1 2000 Tax Amount II $2,818.861 1999 Tax Payment: Whole II ($2,805.40)1 1999 Tax Amount II $2,805.401 Top of Page Assessor Da1abase Search Options I Treasurer Database Search Options Clerk & Recorder Database Search Options D11rfield County Home Page Page 3 of4 The Garfield County Assessor and Treasurer's Offices make every effort to collect and maintain accurate data. However, Good Turns Software and the Garfield County Assessor and Treasurer's Offices are unable to warrant any of the information herein contained. http:/ /www.garcoact.com/assessor/parcel.asp?Parce1Number=2181 05400249 4/14/2008 GARFIELD COUNTY BUILDING AND SANITATION DEPARTMENT 108 Eighth Street, Suite 201 Glenwood Springs, Coloradof 81601 INDIVIDUAL SEWAGE DISPOSAL PERMIT PROPERTY Phone (970) 945-8212 Permit 4448 Assessor's Parcel No. This does not constitute a building or use permit. Owner's Name/t.Jatetf' W\Ctfk 1 LL.c__ Present Address--------------Phone _______ _ system Location 3'8/S·o 8.\Ve.C J:i~.oV\~e M · /V ew Ce-sf1) ~p (~ 4] Legal Description of Assessor 's Parcel No. Ot l~(-oS<../-oC -~Cf CJ !Fu..cf ~ ~'p¢y~1\o" SYSTEM DESIGN _____ Septic Tank Capacity (gallon) ______ O,ther _____ Percolation Rate (minutes/inch) Number of Bedrooms (or other) ____ _ Required Absorption Area • See Attached Special Setback Requirements : Date _____________ Inspector --------------------------- FINAL SYSTEM INSPECTION AND APPROVAL (as installed) Call for Inspection (24 hours notice) Before Covering Installation Syste m Installer _______________________________________ _ Sep t ic Tank Capacity _____________________________________ _ Septic Tank Manufacturer or Trade Name ------------------------------- Septic Tank Access within 8 " of surface ------------------------------- Ab sorption Area --------------------------------------- Absorption Area Type and/or Manufacturer or Trade Name ------------------------- Adequate compliance with County and State regulations/requ irements ___ ·------------------ Other _________________ \~~--.-~~~-------------------- -· ~, <:-!l 1r' 1 1 rl Date j ~,... )J Inspector /( J Ct \~ \ , RETAIN WITH RECEIPT RECORDS AT CONSTRUCTION SITE *CONDITIONS: 1. All install ation must compl y with all requirements of the Co lorado State Board of Health Individual Sewage Disposal Systems Chapter 25, Article 10 C.R.S. 1973, Revised 1984 . 2. This permit is valid only for connect ion to structures which have fully complied with County zoning and building requirements. Con- ne c tion to or use with any d we lling or structures not approved by the Building and Zoning office shall automatically be a violation or a requirement of the permit and cause for both legal action and revocation of the permit. 3. Any person who constructs, alters, or installs an individual sewage disposal system in a manner which Involves a knowing and material variation from the terms or specifications contained In the application of permit commits a Class I, Petty Offense ($500.00 f i ne-6 months in jai l or both). White· APPLICANT Yellow · DEPARTMENT GARFIELD COUNTY SEPTIC PERMIT APPLICATION ..,...._ 108 811' Street, Suite 401, Glenwood Springs, Co 81601 Phone: 970-945-8212/ Fax: 970-384-3470 I Inspection Line: 970-384-5003 f II WW\Y, t!l)_L_!I; __ L ~-~'QUl!l}'_,COlll I Parcel No: (this infonnation is available at the assessors office 970-945-9134) 2 I iS I -0 ":> '1-0 a -2.'-\ C\ 2 Job Address: (if an address has not been assigned, please provide Cr, Hwy or Street Name & City) or and legal description '6\c·q·1-3<6 \'50 'R\\[ER ~l!,oW"T{>,G-'C. N'C:vJ C.A'=>T\..1:0, (.O 3 Lot Size: Lot No: Block No: Subd/ Exemption: '1-22 Ac.. ··ri~.Ac.T :::z. ~'-"'M~' "KI'<'Q'J e-xe-M'?TioN 4 Owner: (property owner) Mailing Add~ess 5$ ~ . , Ph: All Ph: \.1\JQ+~r (fv'\(\f V-).u ,)::J ~0 xbor 0 ((d)' !::16 tp 7 ( 'J.t.( 5 Contractor: Mailing Address Ph: Ali Ph: \?\ \\..)~V...slR' A\.-\\-..:)(_ ;!"'"\I~'~·~ "'"b GO. G> 'i'< o · Z'l '$ ''-11..'1 1. 6 Engineer: t-1!'."'\'11. I!.E"'"-'D. Mailing Address Ph: All Ph: CL.\ E>'>61'-'l'c I<',.._,(, 1\ '2..'\ 7... '-\ .,__ ':::. G-" c.o \1 \'iDS" 'il D ·'2'-\S-OS I '1 c.no -s~o,-«.21..1.. 7 PERMIT REQUEST FOR: (>4 New Installation I I Alteration ( ) Repair 8 WASTE TYPE: I )Dwelling ( )Transient Use (X/ Commercia! or industrial ( )Non-Domestic wastes I )Other-Describe 1--:c--9 BUILDING OR SERVICE TYPE: s;.. o \'Y\ 'i'Y' e--._.. c..\ "-\ Number of bedrooms Garbage Grinder ( )Yes ()<)No 10 SOURCE & TYPE OF WATER SUPPLY: ()<lWELL If supplied by COMMUNITY WATER, give name of supplier: I )SPRING ( )STREAM OR CREEK I )CISTERN II DISTANCE TO NEAREST COMMUNITY SEWER SYSTEM: £:'$00' Was an effort made to connect to the Community System? t--10 -·--·- YOUR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT WILL NOT BE ISSUED WITH OUT A SITE PLAN 12 GROUND CONDITIONS: li. ~., "'>,."" Depth to 1" Ground Water Table 1'\.QY'\e_ Percent Ground Slope 13 TYPE OF INDIVIDUAL SEWAGE DISPOSAL SYSTEM (ISDS) PROPOSED: I)() septic Tank ( )Aeration Plant ( )Vault ( )Vault Privy ( )Composling Toilet ( )Recycling, Potable Use ( )Recycling, other use ( )Pit Privy ( )Incineration Toilet ( )Chemical Toilet ( )Other-Describe 14 FINAL DISPOSAL BY: Y]Absorption trench, Bed or Pit ( )Underground Dispersal I )Above Ground Dispersal ( )Evapotranspiration ( )Sand filter Wastewater pond ( )Other-Describe 15 Will effluent be discharged directly into waters of the state? I )YES (~NO 16 PERCOLATION TEST RESULT: (to be completed by Registered Professional Engineer, if the Engineer does the Percolation' Test) s Le.. e r-~· ('\ IZ.t!. rc.9-&.e. ~i.~V'. Minutes \ 'LO per inch in hole No.1 Minutes \'2,o per inch in hole No.3 Minutes Gl. per inch in hole No.2 Minutes per inch in hole No. ___ Name, address & telephone of RPE who made soil absorption test: \n"'-c."'-o '-->'<. _____ll__"l,<\ 2.'< "i\b G. R ""'~ '3 c.:~ Lo ~ \ S" :> Name, address & telephone of RPE responsible for design of the system: _::r:s."' c."-b '-> l<. \12.'1 2"' 1>.& (-.~A >ob ::. .;,-r c,;::. 1.' 1 s.o 17 Applicant acknoWledges that th8-Compl8teness of the application iS_C_O_ndit!on3i upon such {U-rther.inandatory and additior1.3fi8st -and reports as may be feQ.Ui;:e(fbY the local health department to be made and furnished by the applicant or by the local health department for purposed of the evaluation of the application; and the ISSuance ot the permit IS subje t-t~ such terms and cond1t1ons as deemed necessary to 1nsure compliance Wllh 1u1es and regulations made, UlfOimaliO!l i:lfld ., ... ·-·-~~' 00 ... ,. " •••• ,,~, " ...... ~~' ••• ~ ,_'" ~' """ """"'" """ "~ and are des1gned to be rei! don y the local department of health in evaluatmg the same for purposes of 1ssu1ng the permlt apphed for herem. 1 further understand that any falsiflc/Jiio or misrepresen ~on may result In the demal of the application or reva of any permit granted based upon Said application and legal aclion for perjury a rov1ded ti~!llv ~~ 0 J S J 6 "J OWNERS SIGNATURE-,~---___ ( ~ ------AT ' ---- STAFF USE ONLY ---··- Permit Fee: Perk Fee: Total rees: Building Permit#: '13 ()\_) ·-'l $ .U/) ;'OC(3g Septic Permit #: /j0[tj,_'i)' Issu~Sfd-0 jo2' Building & Planning Dept: APPROVAL DATE