HomeMy WebLinkAboutApplication- PermitJob Address No. 6485 GARFIIELD COUNTY BUILDING, SANITATION and PLANNING DEPARTMENT 109 8th Street Suite 303 GIcnwood Springs, Colorado 81601 (303) 445-8212 Highway 6 & 24, Rifle Nature of Work Building Permit Use of -Building Shop Building Ow�,er David & Anna Johnson Contractor Johnson Construction, Inc. Amount of Permit.5 1412.40 Date September 25, 1997 Permit: 856.00 Plan : 556.40 Paid $556.40 S. Archuleta Cleric Fetes -28-97 05:07p Stella Archuleta Ap.licant to corn Lot-• 970-945-7785 P_01 BUILDING PERMIT APPLICATION / / OAAFIELD COUNTY. COLORADO { f � QJ 2 42t 76e2 :�` late numbered s•aces only. PERMIT NO. p 5/(S PARCELJSCHED NO, �j {/ -'4 J OB A].)REss To be determined 2 LEGAL LOT NO OESCR BLOCK OWNER David and Anna Johnson 3 CONTRACTOR Johnson Const. Inc. 5UBOIVISION Legal description attached ADDREss 2720 Railroad Ave. Rifle, CO ADDRESS Same P F625-2251 WK PH same PH same LICENSE NO 4 ARCHITECT CR DESIGNER MSS, Inc. 5 ENGINEER Charles Robinson 6 S.F OFeUILDING 5760 ADDRESS St. Louis Park, MN JD 5. Grant Ste' AODREss Fort C g17 ins CO SFOFLCT 142000 PH P H 493-0178 LICENSE NO LICENSE NO. 9972 HEIGHT 271 511 NO OF FLOORS 1 7 use OF BUILDING Construction company shop building 8 9 CLAse OF WORK! X, NEW o ADDITION ❑ ALTERATION ❑ REPAIR a MOVE ❑ REMOVE DESCRIBE -WORK Erect Steel Building 10 GARAGE SINGLE DOUBLE CARPORT SNGLE DCUBLE DRNEWAY PERMIT ON SITE SEWAGE" DISPOSAL_ PERMIT ShTE PLAN 11 VALUATION or WORKS SPECAL CONDITIONS ACJ UST ED VAL S 5Z & '/4.6/7=Jjl7.aV NOTICE SEPARATE PERMITS ARE RECUrREG FCR ELECTRICAL, PLUMBING HEATING. VENTILATING OR AIR CCNDITi6NING THIS PERMIT BECOMES NULL AND VOID IF WORK OR CCNSTRLCTICN A„""-4CRIZED IS NOT COMMENCED WITHIN 18C DAYS CR iF CONSTRUCTION CR WORK 15 SUSPENDED OR ABANDONED FCR A PEACO OF :se DAYS AT AN' TIME AFTER WCRit i5 COMMENCED HEREBY CERTIFf THAT I HAVE READ AND EXAMINED fl -as APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED H EREIN CR NOT THE GRANTING OF A PERMIT COES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE CR CANC L THE PR0V151ON5 OF ANY OTHER STATE OR LOCAL LAW RFhGi (,ATING, r. STRUCT,CN OR THE PERFORMANCE OF CONSTRUCTION Signature of tor or .UTncnsed agent Da;e} / 97 g read an Jr,delstooa nonce axve ul eng Depa nt Approval Per ling .: pa . ant • ['pros/el/Pete PLAN CHECK FEE 5-5� Y� PERMIT ^ EE/ 75 J Q SCHOOL IMPACTFEE NO OF BUILDNGS ON PARCEL USE OF BUILDING PARCE. 0 S NOW ON TOTAL F=O/ reAMO WA -7,R SUPPLY CCC GR,..5 SoE:AL APPROVALS CONST TYPE { -.fl' DATEPER mi" ISSUED — 97 RECO RED RECFNED NCT REOU1RE. ZONING HEALTH DEPT FIRE DEPT SC'L REPCRT SETBACKS FLOOC.HA�ARD MANUF HOME /L! DTHE=,, , AGREEMENT SSrelY6U1 PERMISSION IS HEREBY GRANTED TO THE APPLICANT AS OWNER, CONTRACTOR ANC/OR THE AGENT OF THE CONTRACTOR OR OWNER TO CONSTRUCT THE STRUCTURE AS DETAILED ON PLANS ANC SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT IN CONSIDERATION OF THE ISSUANCEE-OF THIS PERMIT THE SIGNER HEREBY AGREES TO COMPLY WITH ALL BUILDING -CODES Amp USE REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN IN 30.26.201 CRS AS AMENDED. THE SIGNER FURTHER AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPLIED WITH IN THE LOCATION, ERECTION, CCNSTRUCTION AND USE OF THE ABOVE DESCRIBED STRUCTURE, THE PERMIT MAY THEN BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT SHALL BECOME NULL AND VOIC THE ISSUANCE OF A PERMIT BASED UPON PLANS, SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS :N SAID PLANS, SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING BUILDING OPERATION BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF THIS CODE OR ANY OTHER ORDINANCE OR REGULATION OF THIS JURISDICTION. THE REVIEW OF THE SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN ACCEPTANCE OF ANY RESPONSIBILITIES CR LIABILITIES BY GARFIELD COUNTY FOR ERRORS, OMISSIONS OR DISCREPANCIES. THE RESPONSIBILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICALLY WITH THE ARCHITECT, DESIGNER, BUILDER ANO OWNER. COMMENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS INTEREST. �4 A� 0 Garform,003 5"401 HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE trNITIAL Feb -28-97 05:O8P Stella Archuleta 970-945-7785 P_02 The following items are required by Garfield County for a final inspection: 1. A final Electrical Inspection from the Colorado State Electrical Inspector, 2, Permanent address assigned by Garfield County Building Department posted where readily visible from access road, 3. A finished roof, a lockable house, complete exterior siding, exterior doors and windows installed, a complete kitchen with cabinets, a sink with hot & cold running water, non-absorbent kitchen floor coverings, counter tops and finished walls, ready for stove and refrigerator, all necessary plumbing; 4. A complete bathroom. with wash bowl, tub or shower. toilet stool, hot and cold running water, non-absorbent floors and walls finished and a privacy door; 5 All steps outside or inside over three (3) steps must have handrails, guard rails on balconies or decks aver 30" high constructed to all 1994 UBC requirements; 6. Outside grading done to where water will detour away from the building_ 7. Exceptions to the outside steps. decks and grading may be made upon the demonstration of extenuating circumstances, i.e. weather, but a Certificate of Occupancy will not be issued until all the required items are completed and a final inspection made A CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL ALL THE .ABOVE ITEMS HAVE BEEN COMPLETED. ****Cannot occupy or use dwelling until a Certificate of Occupancy (C O) is issued Occupancy or use of dwelling without a C 0 Will be considered an illegal occupancy and may be szrounds for vacatinz premises until above conditions are met I understand and agree to abide by the above conditions for occupancy, use and the issuance of a Certificate of Occupancy for the dwelling under building permit # Date Rob Thomas 101 West 26th Street • Rifle, Colorado 81650 • (970) 625-2585 Revegatation Plan Johnson Construction Company yard frontage at Lacy Park. It is proposed to provide Xeriscaping in the form of native grasses and brush in the disturbed area between the 50 foot storage setback line and the Highway R/W line as shown on the attached plot -plan. It is further proposed to place an irrigated entrance planting of Rocky Mountain Junipers around an entrance sign, with Native Yucca Shrubs in front. Brush to be seeded will be four wing saltbrush and greasewood. Native grasses will be buffalo grass and crested wheat. The soil will be fertilized at the rate of 400 lbs/acre and incorporated into the soil by scarification. The seed will be drilled into the prepared seed bed. We hope to do the planting this fall, to take advantage of the fall and winter precipatation, which will encourage growth next spring. Zz7pd b : Bob Thomas Manager CITY of RIFLE 202 RAILROAD AVENUE • P.O. BOX 1908 • RIFLE, COLORADO 81650 • (970) 625-2121 • FAX (970) 625-3210 September 9, 1997 Mr. Dave Johnson Johnosn Construction, Inc. 1920 Hwy. 13 Rifle, CO 81650 Dear Mr. Johnson: -I have had an opportunity to review the landscape plan submitted by a Creek Meadows Gardens for your proposed base facilities at Lacy Park. I spoke with Mr: Bob Thomas of Creek Meadows and he explained the limitations associated with the site and irrigated landscape. The plan contains a portion -of irrigated planting mixed with native Xeriscaping. This plan is acceptable to the City of Rifle if it is constructed ans planned. Sincerel Tim Moore, City Engineer Feb -28-97 05:08P Stella Archuleta 970-945-7785 P.03 GARFIELD COUNTY BU'Il.l)ING AND PLANNING 970-945-82 2 MINIMUM APPLICATION REQUIREMENTS for SINGLE FAMILY DWELLING CONSTRUCTION includinf4 NEW CONSTRUCTION MANUFACTURED HOMES ADDITIONS ALTERATIONS and MOVED B1..1I_DJNG 1n order to understand the scope of the \vork intended under a per t appllcatior and expedite the issuance of a permit it is important that complete information be prcl\id`d. .Adequate and complete information «ill prevent dela s in the plan r4viev process Revie\\ init a plan and the discover.. that required information has not been provided b. the applicant may result in the dela\ of the permit Issuance and to proceeding with buildtnu construction. The owner or contractor may be required to provide this informanon before the pian review may proceed This causes delays because other plans that are in 2n for revie« may be Liven attention before the new information rnav be reviewed after it has been provided to the Buildtna Department, Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. if you do not, it may be helpful to obtain a book titled "Dwellin? Construction under the Uniform Building Code". This book is available to you through this department at our cost. .also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. To provide far a more understandable plan in order to determine compliance with the buildint„ plumbinu and mechanical codes. applicants are requested to review the following, check list prior to and durinu design. Applicants are require to indicate appropriately and to submit the completed check list at time of application for a permit. For the placement of a manufactured (home, questions numbers 1-4 and 19-2S are the only questions that need to be addressed: Fete -28x97 05:09P Stella Archuleta 970-945-7785 P_O4 is a site plan included that indicates the distances of the proposed buildin;r or addition to property lines, other buildinus, set back easements and utility easements1 1•es Does the site plan include the location of the IS DS r Indi\ idual Se'xae Disposal System) and the distances to property lines. wells ion subject propert and adjacent properties i. streams or \\ atet courses" Y e s Does the site pian indicate the location and direction of he County or n~\ are road accessing the grope.. zv' Yes v"-- 4 4 Do the plans include a foundation plan indicatin_T the size. location and soacinLl or all retnfcrcinu steel in accordance with the uniform building code or 'ler stamped ens•sneered desiun' Yes ✓ Do the plans indicate the location and size of ver:tt.atron onenin:s or ;:nde- t'c,c.r c. _,.,' sit. -:laces and the clearances required berv.een wood and earth's Yes A Do the plans indicate the size and location of ventiiatton openings rc.r :ne arTic. 700f iaist sra;es and sor:irs' Yes N� 7 Do the plans include desi_n toads as required under the Uniform m B ::'.; it Code for roof sno'.v loads. (a min mum or -#u pounds per square foot in Gar,eid County i. C,,00r loads and v, ind loads' 1'es ✓ 8 Does the plan include a building section drawing tndicattnu foundation, wall. floor and roof Construction'' Yes ✓ 9 Does the building section draw-ino_ include size and spacirw of floor joists. a a'? studs, ceiling joists, roof ratters or joists or trusses'' Yes 10 Does the building section drawing or other detail include the method of positive connection of all columnsand beams.' Yes' F$b-28--97 05:10P Stella Archuleta 970-945-7785 P.05 I I Dees the pian indicate th.e hei,ht of the buildin=t or proposed additinr; from the hwhest point of the buildin2 or addition measured at mid span between the ridge and the eave down to esistinit <=racle contours') Yes ►f 1= Does the plan include any stove or zero clearance fireplace planned fo- installation inciudinu make and model and Colorado Phase 11 certifications or phase II EPA ce7.ification1 Yes No V- 13 Does the plan include a rnasonn. ft7epiace inciudintl. a fireplace section indicatiri desiEn to comply with the Uniform Building Code Chapter 3" Yes \\o ✓ 14 Does the plan include a window schedule or other verification that e cess rescue windows from sieepint.: rooms and,or basements comply with the requirements of the Uniform Buiidin , Code' Yes No ,U A i 5 Does the pian include a ,.G-Lndcw schedule or other it e-iticarion that u;ndows p.re,t;de natura? '1 ht and ventil tion for all, habitable rooms' Yes ✓ to Do the plans indicate the location of !_i azfrai subject to :human impact such as iJ as_ doors.iaz:nsc immediately adjacent re such doors. z'azin adjacent to anv surface norma'ily used as a surface, glass doors. i\ed Mass panels. shover doors and tub enclosures and specifi safety szlazinry for these areas' i 7 [stile location of all natural and liquid petroleum as furnaces, bo;:e-s and water heaters indicated on the plan' Yes -L b e. 1-#.-.5 18 Do you understand that if You belonu. to a homeowners association, it is your responsibility to obtain written permission fro the associiation. if required by that association. prior to submittint an application for a buildinrt permit') Yes No _ 19ill this bs.the only rel structure on the parcel" Yes No If no -Explain. 20 Have two (2) complete sets of construction drawings been submitted with the application' Yes 3 r - r Fab -28-97 05:11P Stella Archuleta 970-945--7785 P.06 21 is this an application for the placement of a manufactured home's Yes No lives. have vou specified the size of the unit ( min 20ft x 2O). live roof load ( min 40,-t0. wind desiirn ( min wind speed of SO mph & 15 lb wind load). foundation desilun. method of anchorin0 Yes t% Have you designed or had this plan desicned while considerin<i buiidinc and other construction code requirements'' Yes ✓ No Does the plan accurately indicate t,Jnat you intend to construct and what will receive a final inspection by the Garfield Count.:,. Budin Department' Yes ✓ No = Do vou understand that approval for desum and or construction chances are reouired prior to the application of these chances' Yes 1/ No Do VOL} understand tha: the Buiidinc Department will collect a "P!an Re%,ie'a" fee From vou at the time of application and tha: you will be rec uired to pay the "Permit Fee' as e';' as any "School Impact" or Septic System" fees required. at the time vou pick cry your buiidinc. permit' Yes ✓ No ;i 26 Are you aware that twenty four (24) hour notice is required for al] inspections? Inspections will be made from Battlement Mesa to West Glenwood in the mornings and from Glenwood Springs to Carbondale in the afternoon. Morning inspections must be called in by 12:00 p.m. the day before: afternoon inspections must be called in by 5:00 p.m_ the day before. Failure to give twenty four (:4) hour notice for inspections will delay your inspection one (1) day? Yes 17 Are V31.1 aware that you are required to call for all inspections required under the Uniform Building Code inciudin�t approval on a final inspection prior to receivirw a Certificate of -Occupancy and occupancy of the buildinru`' Yes ' No 28 Are vou aware that the person signinc2 the Permit Application. whether the "Owner". "AS7ent of the Owner". "General Contractor', "Contractor" or otherwise, is the party responsible for the project cor ipiving with the Uniform Building Code' Yes ✓ No 4 Feb -28-97 O5:12P Stella Archuleta 970-945-7785 P_O7 I hereby acknowledge that I have read. understand and answered them. questions to the best of my ability. Phone 625-2251 Project \arae • 1 . .e davs), date 625-2888 1 eveninus i .. • . . ... i Projec, address To be determined Lole; Ilyon ha\e ans-sAeroz .,`o,. on and o! the questions. %ou ni:11 h rCQuired t0 pro1'IL� thi inforT1 aims J` lel r till t of OK: 1 ;IIIIClir. Off,:ial prior to negutnunc the plan rel lett proce:,s. pLrrnit arc to h': .:\'.)ti:l;;Li Work I1ra1 without the issuance of a peanut. If it is determined h\ tilt:tha: add}n1011aI info oration ni;.-�- ar'.. 10 r 11L'1l the application and plans to c.Ltcrnune mm11nIIIn alio^ted :LdL'�. Lilt ar)ni1 :I l'' illi\ hl' rric)i.: racer)! 3ppbuauon.; for :)tulduat Nrtxuts un the reviem and not rd'. lewcd until required Laiorrn.1;lun na: 'r,�'cn prnl !ded and the appl:.:auon rotates again to fust position for rev;e,.\ dela I•ssuan,x of the permit or d;::a\ lI D70, ,...;61.11`.2 1%idi N.:on:tru-tiorl Per.AopO2 ai e i INSPECTION WILL NOT BE MADE UNLESS THIS CARD IS POSTED ON THE JOB 24 HOURS NOTICE REQUIRED FOR INSPECTIONS i BUILDING PERMIT ARFIELD COUNTY, COLORA j1.. Date Issued. L.ned Area Permit NoDO es— AGREEMENT In consideration of the issuance of this permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building Inspector an I ME TELY BECOME NULL AND VOID. Use Addegal Description Own N.1- c/ iebc#4,e. Q I ZPiaflkolso Contractor �J J Jsow e#44$7, F This Card Must Be Posted So It is Plainly Visible From The Street Until Final Inspection. INSPECTION RECORD Footing r-, _ P? _07 A 2 Nn Foundation f (7 2,j - ai -7 A (L, (- Underground Plumbing r 0 10.-97 Insulation j 2 7,s-z=r Rough Plumbing J -Z-,Pcre vv\ Drywall, ,, _ _2_5- ___,,,-/ 1., , Chimney & Vent Electric Final (by State Inspector) --_ , �,S ,. Ah Gas Piping -3 _3 i_ c (4_ A A Final L=-6, _f;e:f _, Electric Rough (By State Inspector) f-gi,-,- ', , Septic Final / / _ pi - -, Framing -" JL 7 -`71('4.e, (To include Roof in place and Windows and Doors installed). Notes: ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING - WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND. 9/.5.9 THIS PERMIT I5 NOT TRANSFERABLE Phone 945411111t 109 8th Street County Courthouse Glenwood Springs, Colorado. APP 0 EDDO NOT DESTROY THIS CARD By IF PLACED OUTSIDE - OVER WITH CLEAR PLASTIC Datg0/8120J