Loading...
HomeMy WebLinkAboutApplication- PermitGarfield County • Building & Sanitation Department 108 8t Street, Suite #201 Glenwood Springs, Co. 81601 Office- 945-8212 Inspection Line- 384-5003 NO. CI, S� Job Addressh ( no (G' ?C Nature of Work Building Perin ;Y ,'�qC)'% - 1 c 7- 0c)) - cc Use of Building A , q ---f—D)J2,‘(. Owner t t [Q , A Contractor ( \C) Amount of Permit $ 7 ! 3ci. 9?,1f-- nc" Date Clerk Q,,) 60P, Permit No: GARFIELD COUNTY BUILDING PERMIT APPLICATION 108 811' Street, Suite 201, Glenwood Springs, CO 81601 Phone: 970-945-82121 Fax: 970-384-3470) Inspection Line: 970-384-5003 J k Parcel/Schedule No: ,D`t U7 -7 ` f ' ( � �D 1 AGREEMENT Oik PERMISSION IS HEREBY GRANTED TO THE APPLICANTAS ER, CONTRACTOR AND7OR THE AGENT OF THE CONTRACTOR OR OWNER TO CONST4iUCT THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT. IN CONSIDERATION OF THE ISSSUANCE OF THIS PERMIT, THE SIGNER. HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND USE REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN IN 34.28201 CRS AS AMENDED. THE SIGNER FURTHER AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPILED WITH IN THE LCOATION, ERECTION, CONSTRUCTION, AND USE OF THE ABOVE DESCRIBED STRUCTURE, THE PERMIT MAY BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE 1T SHALL BECOME NULL AND VOID. THE ISSUANCE OF A PER.MT BASED UPON PLANS, SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING BUILDING OPERATION BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF THS CODE OR ANY OTHER ORDINANCE OR REGULATION OF THIS JURISDICTION. THE REVIEW OF SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABLTTIES BY GARFIELD COUNTY FOR ERRORS, OMISSIONS OR DISCREPENCIES. THE RESPONSIBILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICIALLV WITH THE ARTICTECT, DESIGNER, BUILDER, AND OWNER. COMMENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS INTEREST. Garfom.003 I HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE (INITIAL): IL Job Address: �I„ 1-4; es-- l �� r' r� rPCLA-a-e- / 7s Bit !`�y !/ t0.7 [--�O 1 Lot No: Blqt o:V Subd / l;xemption: , ° '\- .4= L ' `,1 tEifL1 Li_ At/ L yi 2 Owner: (.,=' 112.11c LJ 406/1,0 -CI cess In �� ' �y tJJ' ((- , r,. Ph: 7c, 5 D-3 - - `=.a"--. Wk Ph: 3 ntractor: 1 (A -Le I'vc-vo,� Address:Ph: .. Lic. No. 4 )hite sneer Address: 6Ph: (} Lic. Na. 5 Sq. Ft. of Building:17 Sq. Ft. of Lot: Height: No. of Floors: 6 Use of Building: ivi cL �} _ tkv` ('C� C7 1 ' i 1, , 5 , C ' `r 7 Describe Work: 8 Class of Work: ,,a— New o Alteration ❑ Remove o Addition o Move 9 10 Garage: Single o Double Carport: ❑ Single ❑ Double 12K Driveway Perm't o On -Site Sewage Disposal ID---- 'site Plan C (Septic) 11 Valuatio of Work. S Adjusted Valuations: S .3 (�'` f �` C9 Special Candi ons: "� - "Umtt t3 3! �'t^"""� � Q.o.r • Ga.: 00 53 C,.►ti. ,, C,'icI - '1114''`tD -: O 05 9 R rpt 1+ cal c i rc l� d 06 ! � „� { he.. C 1' rc !t •-+ 1or; 5 qqtrr pp�� Ci 155 NOTICE A SEPARATE ELECTRICAL PERMIT IS REQUIRED AND MUST BE BY THE STATE OF COLORADO. S PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION THIS AUTHORIZED IS NOT COMMENCED WITHIN ISO DAYS, OR. IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED.4134 I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS GOVERNING THIS TYPE OF WORK WILL BE COMPLETED WITHIN WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. ' kA A.L-E-% �! Pldit'Rtfck Fee: /� L , 4 Permit Fee: 75THIISSUED 25.05.75 - Total Fee: Dated Permit Issued Ka .Tyr �c Fee_ C 72 i .1 CA f, , 4/1-d905-0 - -)039‘_ p 9 OCC GrouQ Vist. Type: en'' 11 f"+} Zoning: 1 Setbacks: Manu. Home: ISDS No�: / '6 C. 0' I I O NER f di)V � I PAPPL G. D PR ' � L 7 DATE APP}l0 AGREEMENT Oik PERMISSION IS HEREBY GRANTED TO THE APPLICANTAS ER, CONTRACTOR AND7OR THE AGENT OF THE CONTRACTOR OR OWNER TO CONST4iUCT THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT. IN CONSIDERATION OF THE ISSSUANCE OF THIS PERMIT, THE SIGNER. HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND USE REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN IN 34.28201 CRS AS AMENDED. THE SIGNER FURTHER AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPILED WITH IN THE LCOATION, ERECTION, CONSTRUCTION, AND USE OF THE ABOVE DESCRIBED STRUCTURE, THE PERMIT MAY BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE 1T SHALL BECOME NULL AND VOID. THE ISSUANCE OF A PER.MT BASED UPON PLANS, SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING BUILDING OPERATION BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF THS CODE OR ANY OTHER ORDINANCE OR REGULATION OF THIS JURISDICTION. THE REVIEW OF SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABLTTIES BY GARFIELD COUNTY FOR ERRORS, OMISSIONS OR DISCREPENCIES. THE RESPONSIBILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICIALLV WITH THE ARTICTECT, DESIGNER, BUILDER, AND OWNER. COMMENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS INTEREST. Garfom.003 I HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE (INITIAL): IL The following items are required by Garfield County for a final inspection: 1. A final Electrical Inspection from the Colorado State Electrical Inspector 2. Permanent address assigned by Garfield County Building Department posted where readily visible from access road; 3. A finished roof, a lockable house, complete exterior siding, exterior doors and windows installed, a complete kitchen with cabinets, a sink with hot & cold running water, non- absorbent kitchen floor coverings, counter tops and finished walls, ready for stove and refrigerator, all necessary plumbing; 4. A complete bathroom, with washbowl, tub or shower, toilet stool, hot and cold running water, non-absorbent floors and walls finished and a privacy door; 5. All steps outside or inside over three (3) steps must have handrails, guard rails on balconies or decks over 30" high constructed to all 1997 UBC requirements; 6. Outside grading done to where water will detour away from the building; 7. Exceptions to the outside steps, decks and grading may be made upon the demonstration of extenuating circumstances, i.e. weather, but a Certificate of Occupancy will not be issued until all the required items are completed and a final inspection made. A CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. ****CANNOTOCCUPY OR USE DWELLING UNTIL A CERTIFICATE OF OCCUPANCY (C.O.) 1S ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISE UNTIL ABOVE CONDITIONS ARE MET. I understand and agree to abide by the above conditions for occupancy, use and the issuance of a Certificate of Occupancy for the dwelling under building permit# `1/Si11 r/YI I'i. 4i /' �La i��V , �6 J, 9/1117/1- Si i nature . Dat6 BpcontO82002 Applicant VALUATION/FEE DETERMINATION Addres Date i Finished (Livable Area): Main Upper Lower Other ager le Data 2540 Total Square Feet Valuation Basement: Unfinished Conversion of Unfinished to Finished Plan Check Fee for Conversion Valuation Garage: Crawl Space: Valuation dQ, Valuation Decks/Patios: Covered Valuation Open Valuation Total Valuation 2)( Subdivision Va 41� Vi Eu") Vi (1415 Lot/Block c„ a-- c Contractor Grace how ?S d,., trlfiV , 25 k = S .CD 1 = 34 8450 44 8957 /8 =1 ,164 So x2'1 = 620 x = 2Z GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS FOR CONSTRUCTION OF COMMERCIAL OR MULTI -FAMILY RESIDENTIAL BUILDINGS including NEW CONSTRUCTION ADDITIONS ALTERATIONS and MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. Adequate and complete information will prevent delays in the plan review process. Reviewing a plan and the discovery that required information has not been provided by the applicant may result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor may be required to provide this information before the plan review may proceed. This causes delays because other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. If you do not, it may be helpful to obtain a book titled "Dwelling Construction Under the Uniform Building Code". This book is available to you through this department at our cost. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following checklist prior to and during design. 1 Plans to be included for a Building Permit must be on draft paper at least 18"x 24"" and drawn to scale. Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks, balcony steps, hand rails and guard rails, windows and doors, including the finish grade line. A section showing in detail, from the bottom of the footing to the top of the roof, including re -bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house -rap, (which is required), siding or any approved building material. A window schedule. A door schedule. A floor framing plan, a roofing framing plan, roof must be designed to withstand a 40 pound per square foot. up to 7,000 feet in elevation, an 80 M.P.H. windshear, wind exposure B, windload of 15 pounds per square foot and a 36 inch frost depth. All sheets to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be incompliance with the 1997 UBC, UMC and 1997 UPC. Applicants are required to indicate appropriately and to submit completed checklist at time of application for a permit: 1. Is a site plan included that identifies the location of the proposed structure, additions or other buildings, setback easements, and utility easements showing distances to the property lines from each corner of the proposed structure prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Slopes of 30% or more on properties must be show on site plan. NOTE: 106.3.1 (7.) Any site plan for the placement of any portion of a structure within 50 ft. of a property line and not within a previously surveyed building envelope on a subdivision final plat shall be prepared by a licensed surveyor and have the surveyors signature and professional stamp on the drawing. Any structure to be built within a building envelope of a lot shown on a recorded subdivision plat, shall include a copy of the building envelope as it is shown on the fina) plat with the proposed structure located within the envelope. Yes ✓✓ 2. Does the site plan when applicable include the location of the I.S.D.S. (Individual Sewage Disposal System) and distances to the property lines, wells (on subject property and adjacent properties), streams or water courses? This information must be certified by a licensed surveyor with their signature and professional stamp on the design. Yes V No _ Not necessary for this project 3. Are the plans submitted for application review construction drawings and not drawings that are stamped or marked identifying them as "Not for construction, for permit issuance 2 only", "Approval drawings only", "For permit issuance only" or similar Language? Yes (/ No Not necessary for this project 4. Is the I.S.D.S. (Individual Sewage Disposal System) designed, stamped and signed by a Colorado Registered Engineer? Yes No Not necessary for this project 5. Does the site plan indicate the location and direction of the State, County or private road accessing the property? Yes I, 6. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the uniform building code or per stamped engineered design? Yes k• No Not necessary for this project 7. If the building is a pre-engineered structure, is there a stamped, signed engineered foundation plan for this building? Yes v No Not necessary for this project 8. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and earth? Yes / No Not necessary for project 9. Do the plans indicate the size and location of the ventilation openings for the attic, roof joist spaces and soffits? Yes ✓ No Not necessary for this project 10. Do the plans include design loads as required under the Uniform Building Code for roof snowloads, (a minimum of 40 pounds per square foot in Garfield County)? Yes / No Not necessary for this project 11. Do the plans include design loads as required for floor loads under the Uniform Building Code Chapter 16 and Tables I6A, 16B and 16C? Yes / No Not necessary for this project I2. Does the plan include a building section drawing indicating foundation, wall, floor, and roof construction? Yes / No Not necessary for this project 13. Is the wind speed and exposure design included in the plan? Yes_v - No Not necessary for this project 3 14. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or joists or trusses? Yes No Not necessary for this project 15. Does the building section drawing or other detail include the method of positive connection of all columns and beams? Yes No Not necessary for this project 16. Does the plan indicate the height of the building or proposed addition from the highest point of the building or addition measured at mid span between the ridge and the eave down to existing grade contours? Yes " No Not necessary for this project 17. Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase II certifications or Phase II EPA certification? Yes No Not necessary for this project 18. Does the plan include a masonry fireplace including a fireplace section indicating design to comwith the Uniform Building Code Chapter 31? Yes f No Not necessary for this project 19. Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements comply with the requirements of the Uniform Building Code? Yes ./ No Not necessary for this project 20. Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable rooms? Yes / No Not necessary for this project 21. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety glazing for these areas? Yes ✓ No Not necessary for this project 22. Do the plans include a complete design for all mechanical systems planned for installatn in this building? Yes 1' No Not necessary for this project 23. Have all areas in the building been accurately identified for the intended use? (Occupancy as identified in the Uniform Building Code Table 5-A) Yes 1/ No Not necessary for this project 4 24. Does the plan indicate the quantity, form, use and storage of any hazardous materials that may be in use in this building? Yes t' No Not necessary for this project tl/ 25. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? Yes ✓ No Not necessary for this project 26. Do the plans indicate the location and dimension of restroom facilities and if more than four empl ees and both sexes are employed, facilities for both sexes? Yes No Not necessary for this project 27. Do the plans indicate that restrooms and access to the building are handicapped accessibly? Yes ,/ No Not necessary for this project 28. Have two (2) complete sets of construction drawings been submitted with the application? Yes/ No 29. Have you designed or had this plan designed while considering building and other construction code requirements? Yes ✓ No Not necessary for this project 30. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by the Garfield County Building Department? Yes / No 31. Do your plans comply with all zoning rules and regulations in the County related to your zone district? For corner lots see supplemental section 5.05.03 in the Garfield County Zoning Resolution for setbacks. Yes No 32. Do you understand that approval for design and/or construction changes are required prior to the implementation of these changes? Yes V No 33. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application and that you will be required to pay the "Permit" fee as well as any "Septic System" or "Road Impact" fees required, at the time you pick up your building permit? Yes / No 5 34. Are you aware that you are required to call for all inspections required under the Uniform Building Code including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of the building? Yes V No 35. Are you aware that the Permit Application must be signed by the Owner or a written authority be given for an Agent and that the party responsible for the project must comply with the Uniform Codes? Yes t/ No 36. Are you aware that twenty-four (24) hour notice is required for all inspections? Inspections will be made from Battlement Mesa to West Glenwood in the mornings and from Glenwood Springs to Carbondale, in the afternoon. AU inspections must be called in by 3:30 p.m. the day before. Failure to give twenty-four (24) hour notice for inspections will delay your inspection one (1) day. Inspections are to be called in to 384-5003. 37. Are you aware that requesting inspections on work that is not ready or not accessible will result in a $47.00 re -inspection fee? Yes ( No 38. Are you aware that prior to issuance of a building permit you are required to show proof of a driveway access permit or obtain a statement from the Garfield County Road & Bridge Department stating one is not necessary? You can contact the Road & Bridge Department at 625-8601. Yes ✓ No 39. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups? The license number will be requir d at time of inspection. Yes No 40. Are you aware, that on the front of the building permit application you will need to fill in the Parcell Schedule Number for the lot you are applying for this permit on prior to submitty of the building permit application? Your attention in this is appreciated. Yes No 41. Do you know that the local fire district may require you to submit plans for their review of fire safety issues? Yes No (Please check with the building department about this requirement) 6 I hereby acknowledge that 1 have read, understand, and answered these questions to the best of my ability. A .f 4 _• Si i ature Date Phone:C(70 (393 days); (evenings) Project Address: Ur' ,pCI +� Project Name: Note: If you answered "No" on any of these questions you may be required to provide this information at the request of the Building Official prior to beginning the plan review process. Delays in issuing the permit are to be expected. Work may not proceed without the issuance of the permit. *If you have answered "Not necessary for this project" on any of the questions and it is determined by the Building Official that the information is necessary to review the application and plans to determine minimum compliance with the adopted codes, please expect the following: A. The application may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review. B. Delay in issuance of the permit. C. Delay in proceeding with construction. *lf you answered "No" to this question the circumstances described in the question could result in a "Stop Work Order" being issued or a "Certificate of Occupancy" not being issued. Bpcomm 11 /2003 7 PLAN REVIEW CHECKLIST t4 Date Applicants Ft. Building ,./Engineered Foundation Driveway Permit urveyed Site Plan &J1 A Septic Permit and Setbacks Grade/Topography 30% (Attach Residential Plan Review List --inimum Application Questionnaire "Subdivision Plat Notes Planning/Zoning Property Line Setbacks 30ft Stream Setbacks Flood Plain Building Height Zoning Sign -off Road Impact Fees t.--0A/DRC Approval Grade/Topography 40% Planning Issues Subdivision Plat Notes ✓Fire Department Review mien i N g, r r4440.. 6 -40 -oaf ✓ Valuation Determination/Fees d Line Plans/Stamps/Sticker Attach Conditions —Application Signed �-\=1---Plan Reviewer To Sign Application cation li Parcel/Schedule No. 40# Snowload Letter- Manf. Hms. GENERAL NOTES: Ms. Diana Drussel Grace Homes 786 Valley Ct. Grand Junction, CO. 81505 April 14, 2004 Dear Ms. Drussel: Garfield County BUILDING & PLANNING DEPARTMENT Thank you for your submittal of the site plans last Friday. 1 have continued with the review of the building permits. Upon review of the application for the 4-plex at 63 Angelica, several areas will need to addressed. These areas are as follows: 1. My copies of the plans are not sealed by a licensed architect. The structural drawings are stamped but the architectural drawings are not. Sealed plans are required. 2. As per Sec. 1103.1.9.3 of the code, multi -unit buildings containing four or more dwellings must be built to the accessibility requirements for a Type B dwelling. This allows for the building to be properly sized and adaptable at construction without having to provide all the accessible features required of a Type A building. This requirement is not included with the submitted plans. 3. I have spoken with Brian Sims regarding the lhr. door requirement and the required change to the foundation. Both these requirements are redlined on the plans submitted. The required change to the foundation has been made. The door requirement can be checked in the field. 4. Also redlined on the plans, are the requirements for the engineer of record to inspect the subgrade and foundation prior to the concrete being poured. A letter from the engineer will be required post inspection. 5. As per plat notes associated with the PUD, footer drains and radon testing is required. Both these requirements are noted on the plans. Many of these requirements may apply to the 6-plex pending review. If so, additional submittals will be required for it. With all the projects submitted utilizing the shallow frost protected foundations, an additional insulation inspection will be required prior to backfill to verify the rigid insulation is installed properly as per Sec R403.3 of the 2003 IRC. This inspection can be done by the county inspectors or the engineer of record for the project. Please call if you have any questions. I will continue on with the plan reviews while waiting for the required submittals Sincerely, Andrew Schwaller Building Official 108 8th Street, Suite 201, Glenwood Springs, Colorado 81601 (970) 945-8212 (970) 285-7972 Fax: (970) 384-3970 ... Q1.6&iU( ^iort / Ci)eitx P--/ a:13) -/ 114 634, ro ,rye �`� �- -g 4 com.ftart Ceiv7,1 t -41- i?) 4(A,40 Fooci- rl� !2 o c 1�-1 ) to 302 q 112T -4 -1 r 311 ILLWI R :, glilSgr �hit ) (d -rt J act... _ / -w-t-ru J/0,_2, y152+6 lye�t.c$.�, 0.11, 7Dp - 7.0 ,Sracc 9. � :Dro-fkr 2 ' AT-rca 15t3 t-Coner ( T ent or P 7'6 7 <7 cloe.z.l - 2-4 6 _J6 fly, - 24+d. c.. 7-w0t,e2 BATTLEMENT MESA SERVICE ASSOCIATION ARCHITECTURAL COMMITTEE APPLICATION & CHECKLIST (for New Home Construction projects) Homeowner: �It.Rm. arm ,(211-i U 91 ' imt 4. CAI e Home Mailing Address: 77(0 di/teecc�, / , , q-i[irtA_j%on,/ s-0 S CoCD S Horne Phone: Work Phone (if desired): (920) S2a — D ` 3 00.41-1 Block: 4 Subdivision: VAU.ELTWtil VI L2.A4E -PUD Project Address: (p 9 AOC, GA C12 Lot: 41,p Production Home PlanName (ifapplicable): u/, Homebuilder: JU/1 A LCSC S O1) Business Mailing Address: 7$(0 Business Phone: Q70- 513— D/0 3 *di 11 Ertl l 0. ) (d Ca rvr e_ p� ej-0 ,71505— Fax(ifdesired): y�i6 - 523 1- D/O 3 Submittal Date: Estimated Start Date: Estimated Completion Date: SUBMITTAL REQUIREMENTS: Two Copies each of items 1, 2 & 4 need to be submitted. (Check -off items attached to the Application. Fill in spaces as indicated.) 1. Sit e Plan Drawing (1" = 10' or 1" = 20' scale) with the -following information shown: Lot, Block & Subdivision name. Street Address of Project. Building Setback Lines (also fill-in the shortest distance between property line to the exterior wall closest to that property line). Please be aware that all Building Setback Lines are taken from your Property Line Pins!! Your Property Line is NOT the Curb Line!! DwellinUnit r 'I -/ Front Setback: ,22 lav • Left Side Setback: (s''0" -SF; Right Side Setback: 31' a" Rear Setback: 53 (u �'*y Utility Easements. 55' Clear Site -Line at Intersection Corner Lots. Site Grading Elevations & Drainage. First (main) Floor Height in relation to top of street curb at front -center of lot. Driveways (including width of driveway), Walkways, Patios, etc� Outbuildings. Garage 00 Page 2 of 6 FEB 1 1 2004 2. Architectural Drawings (1/4" = 1' or 1/8" = 1' scale) with the following information shown. ✓ Floor Plan(s) with overall dimensions (fill-in the following square foot areas). First Floor Finished Living Area: Second Floor Finished Living Area: Lower Floor Finished Living Area: Total Finished Living Area: Total Unfinished Living Area: Garage Area: 5, 08(, NA NA SDP la ce=iiy _square feet 487 /o iquare feet square feet 1 21 (0 r ()A)IT- t A square feet 116P 91 Uti I T square feet square feet Building Elevations Plans indicating doors, windows, exterior materials, building height, roof pitch, roof -mounted evaporative coolers, etc. (fill-in maximum height below). Maximum building height to highest ridge line or building structural projection r2.0 $ //z_feet above top of street curb at front -center of your lot. ✓ Engineered (stamped) Foundation Plan. dA Outbuildings indicating dimensions, elevations and overall height to ridge line. 3. Exterior Materials (fill-in the selections below): Roofing Material illan7,44/6 JE7L16,5 - 3o Color: Ak7m/Ez k4 C Primary Siding Material: 41 GOA Color: 69714E2, Accent Siding Material: ✓ Trim Material: ✓ Masonry Material: QUEEN .LOE &a . Stucco Materials: n it Front Door Material: Color: Gt'Hiir Color: COMM— ./ Front /EMM— Color: Ft. -057 -ED ase Color: /hoc_ Color: 1ch/i7 Garage Door Material: Alen? 4 -- COLOR— COLOR SAMPLE COLOR SAMPLE COLOR SAMPLE COLOR SAMPLE Porro 1 of 4 Color: (,vNirE COLOR SAMPLE COLOR SAMPLE ✓ 4. Landscape/Irrigation Plans with the following information: Planting Plan (indicate areas of irrigated lawn, tree placement, shrub beds, ground cover, etc.). ✓ Plant Material listing by species of trees, shrubs and grasses. Groundcover Material with weed control barrier. 11A Fences. Other Landscape Improvements (decks, site lighting, flag poles, etc.). I'c.K A2c111 x 69A4 tinIJtathlrx Reofrr261ut m. VIA 5. Variance Request (if applicable) Give details below: NQ 6. Residential Construction Monetary Deposit: I/We hereby acknowledge and understand that our failure to complete Home Construction, Improvement Projects or Landscaping Construction within the time constraints noted in Conditions 2. & 3. On Page 6 of this Application will result in a Notice and Opportunity for a Hearing before the BMSA Board of Directors. If I/We are found in violation of these Conditions at the Hearing it will result in a fine to the Owner of not less than S500.00 per month for each full month in excess of the allotted completion time frame. I/We hereby acknowledge that Home Construction or Improvement Projects or Landscape Construction features which are built in non-conformance with this full application, including the Conditions of Approval noted on Page 6 of 6 herein, I/We will be cited by the BMSA/AC in written citation form at the time of discovery. In extenuating circumstances a Variance may be requested from the BMSA/AC, provided such Variance request item is within the purview and approval jurisdiction of the BMSA/AC. If a Variance is not granted by the BMSA/AC and if the Non -Conforming Items are not corrected within 60 days after the date of written citation, I/We will be served Notice of a Hearing before the BMSA Board of Directors, and if I/We are found in violation of these Non -Conforming Items at the Hearing 1/We will be fined a minimum of 5500.00 per Non -Conforming Item. Notwithstanding the foregoing, I We acknowledge that the BMSA Board of Directors and/or Architectural Committee may pursue any legal remedy available in the event of a non-compliance. Page 4 of 6 Failure to pay fines levied as determined at the Hearing may also result in a Lien being placed on your Property or litigation Process initiated by the BMSA Board of Directors to secure conformance with this full Application and its respective Conditions Of Approval. I/We understand that Architectural Committee approval does not constitute approval of the local building department, drainage design or structural soundness, nor does it constitute assurance that the plans comply with all applicable codes, regulations, ordinances and laws. I/We further acknowledge that any subsequent field changes which I/We may desire to the Home Construction or Improvement Projects of this original Application Submittal and the original Conditions of Approval issued by the BMSAJAC will require an additional Revised Application Submittal on our behalf, and that I/We will not proceed with any subsequent field changes until a Revised Conditions of Approval have been issued to us by the BMSAJAC. Owner's Signature(s): idAate, )231,46 ittL Owner's Printed Names: )/p Uq Ot? ^ + Date: yiQ¢ cox Gi/Gaeti Lim "/` Date: G07d S-74teepn/ Co .} Act_ G/' i4 4'P Codsa, Cvy /.t✓G BuildersPrintedName: ,9a ritsSef-a, Date: Ink/ Builder's Signature: Page 5 of 6 This portion of the Application Form is to be completed by the Architectural Committee (not the Applicant). CONDITIONS OF APPROVAL or DISAPPROVAL 1. No sitework or building construction may proceed on any Lot (including no preliminary site clearing, grubbing, grade alteration, storing of material, foundation excavation, extension ofunderground utilities, etc.) until the Project has received a Project approval from the Architectural Committee and has been issued a Building Permit (as required by Garfield County for new home or Renovation projects). 2. All general building and site improvements construction for any Project shall be completed and shall have issued a Certificate of Occupancy from the Garfield County Building Department no later than one (1) year after the issuance date of this Architectural Committee Approval. 3. The complete landscaping and revegetation of the improved Lot, to specifically include the front side and rear yard areas, shall be completed no later than six (6) months from the date of the Certificate of Occupancy. 4. If the selection of colors and /or landscaping plans are not included with this application they must be submitted for approval before any action is taken to install the missing items. 5. ,Lectere xt7ts pcbm j..0 t to/La/Ale- J c 'k t 6. 7. Ape_O _ ti. Application pproval (Init of Archit)�n�, Cors): Application Approve. 'or Cons • ction subject to the above conditions: By Chairman: /, _ _✓.:. _—a Date: Application Denied (Initials of Architectural Committee Members): By: Application Denied for reason(s) stated above: By Chairman: Date: Page 6 of 6 04/28/2004 WED 14:18 FAX FAX COVER SHEET Grace Homes Real Estate and Construction Inc. 786 volley Coot Grand Junction. CO 81506 (970)52)-5555 (970) 523-0103 W0001/002 Send to /6* Lc V*A/ :"host/e anducr.... J 17x10: y_ �'rQs� ing. carte Otte Localior>: Grand Junction. CO Fa < Wrnber: tl70 . -SW , 3 070 Phone Number: (5,70)523-5555 Uri Rads ASAP Comment PleasePaiew Fa You Ywomnalon Con neat RE 1' 4-29 ASM 01-7 � WL 'IU 04/28/2004 WED 14:48 FAX 4002/002 qica Homes RFAI FSTATF & CONSTRUCTION • Quality • Value • Integrity Andy Schwaller Chief Building Official Building &Planning Department 108 gth Street, Suite 201 Glenwood Springs, CO 81601 April 28, 2004 Fax#: (970) 384-3470 Dear Andy Schwaller, Thank you for informing the as quickly as you did in regards to the subgrade at our proposed building sites. We were made aware of the issue some time back and we frcd a soils engineer to make sure the building sites have appropriate compaction We have also been assured by our development sub -contractor that no organic material is going in any areas under buildings on the site. Thank you for informing us of this matter and feel free to keep us informed of any issues. Respectfully, atw, 4/ead Diana Drusscl Administrative Assistant 786 Valley Court • Grand Junction. Colorado 81505 Office (970) 523-5555 • Fax (970) 523-0103 Yeh and Associates, Inc. Geotechnical Engineering Consultants 5700 E Evan! Avenue Denver, CO 80222 Tel.: (303) 781-9590 Far (303) 781-9583 April 29, 2004 Mr. Darin Carei Darter, LLC 786 Valley Court Grand Junction, Colorado 81505 420 Seventh Stat, Suite 100 Glenwood Springs, CO 81601 Tel: (970) 384-1500 Fax: (970) 3841501 Proposal No. 2004-P112 Subject: Proposal for Geotechnical Engineering Study, Valley View Village PUD, Phase A, Battlement Mesa, Garfield County, Colorado Dear Mr. Carei: This letter presents Yeh and Associates, Inc. proposed scope of work and estimated project costs for preparation of a geotechnical study for the subject project. Project Description: The project includes subdivision of a parcel of land for residential housing, construction of utilities and roadways. We were provided with a geotechnical report by HP Geotech for the infrastructure and a site -grading plan by High Country Engineers. The client requires a geotechnical study kr the proposed structures to be constructed on the property. Scone of Work: Based on the information provided to us, additional results of field investigation to be performed, and our understanding of the project, we propose the following scope of work for the completion of a geotechnical study: 1. Contract drilling or excavation services for the investigation. This estimate assumes that the client will provide excavation equipment for the test pits. 2. Provide laboratory testing services. 3. Excavate and sample between 12 and 16 borings or test pits at the proposed site. The total number of borings will be determined in the field. Analyze the field data and laboratory test results from the investigation and all pertinent data obtained. Based on this data we will provide a report with recommendations and geotechnical considerations for the following: • An assessment of the groundwater conditions and recommendations for surface and subsurface drainage considerations. • Recommended foundation types and design criteria based on the site and subsurface conditions. • Lateral earth pressures for foundation walls. ■ Corrosive potential, if any, of soils on concrete. ■ Backfill soil type and degree of compaction and suitability of on-site soils for use on the project. RECEIVED Foundation construction criteria. A slope stability evaluation and recommendations for mitigation of the potential MAY 0 5 slope hazard. 2004 GARFIELD COUNTY BUILDING & PLANNING -d 0026 13rd3SH1 dH Wd80:T 4002 CO ALM 4. We will observe and document site-specific foundation conditions at the time of excavation for each of the 11 planned structures. Our estimate is based on 3 hours per site for the 11 sites. Contact drilling or excavation services (Task #1) if needed, will be charged at cost plus 15%. The client will be invoiced in accordance with the attached Standard Fee Schedule and General Conditions for all other work. We estimate the following approximate costs for the project: Task 1 (Excavation) Task 2 (Lab) Task 3 (Report) Task 4 (Observation) Mileage and Other Direct Costs Estimated Costs If you have any questions, please feel Gee to call. Roger PihI P.G. Principal Attachment: Fee Schedule General Conditions cc: Ronald Weidler, High Country Engineering c d $ 0 $ 1,500 $ 3,850 $ 2,200 $ 100 $ 7,650 Accepted by. Date: (return by fax to 970-384-1501) 002C 131'213SW- dH Wd80:I fr002 CO MAW Dec 17 2004 11:11AM LOWER VALLEY ENGINEERING (970) 858-2005 • Van tapdanf hi, Asa wa sa...ss... D.an n.es, Solss Pk4WS)+s t ss4rn)ww Andy Schwaller Garfield County Building Department Fax: 970-384-3470 12-16-04 RE: Glace Homes Valley View Battlement Mesa, Fourplex at 0051, 0053, 0059 Angelica Circle. Building Department I have been mtained by Grace Homes to provide engineering services for the above referenced project I have supervised inspection of the foundations and walls prior to concrete placement to ensu conformance with the drawings that I prepared and were submitted for permit. The foundation are structurally adequate to satisfy the building codes currently adopted by Garfield County. Please contact me if there am any questions concerning this project. Signed, Darren R. Adams, P. E 1 p.1 Dec O9 04 03:L7p Battlement -Mesa Metro Dis 9702859631 p.1 BATTLEMENT MESA METROPOLITAN DISTRICT 1 ORISIC TRAIL. / P.O. BOX 6116 / BATTLEMENT MESA, CO 81636 (970) 285-9050 / FAX (970) 285-9631 2.004 LPLiAACSIMILE TRANSMISSION "bate: 12/9/04 TO: Andy Schwaller COMPANY: Garfield Cty Building and Planning FAX NUMBER: 384-3470 FROM: Amie Arneson FAX NUMBER: 970-285-9631 MESSAGE We have approved water and sewer connections and set meters at 53 Angelica Circle and 57 Angelica Circle. The tap fees have also been paid on this entire unit. Thanks Andy, Amie TOTAL NUMBER OF PAGES: 1 CONFIDENTIALITY NOTICE: This fax communication isintendedonly for the above-named recipient. If you have received this transmission in error, please call (970)285-9050 as soon as possible. It is unlawful to disclose, in any manner, such confidential information to anyone other than the person to whom it is directed. No G1 76 .Job Ad Owne BUILDING PERM Assessor's Parcel No RD i Date 07- ss Contractor Setbacks Lu lJ� Acs L1plL Soils Test Footing Foundation Grout Underground Plumbin Rough Plumbing Framing Insulation Roofing Drywall /0IQ- Gas Piping 70-5--0 l tin of— Front f Front Rear Address Address RH INSPECTIONS LH e Phone # Phone # Zoning 2$5- 9833 L Weatherproofing Mechanical Electrical Rough (State) /0-/1 .-o T Z4 -c Electri l F'nal tate) /2 -t-OT Final Al khst Completed? ' Certificate Occupancy # Date Septic System # Date Final efither NOTE 0.14 C7- s (continue on back),e ' n-! INSPECTION WILL NOT BE MADE UNLESS • THIS CARD IS POSTED ON THE JOB 24 HOURS NOTICE REQUIRED FOR INSPECTIONS BUILDING PERMIT GARFIELD COUNTY, COLORADO Date Issueda{.q..Zoned Area Permit No.....1..f5. II AGREEMENT In consideration of the issuance of this permit, the applicant hereby agrees to comply with all Iaws and regulations related to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building Inspector ano IMM LATELY (BEECOME NULL AND VOID. Use (Anna" 1 04 1 Piet/� ./� Addres Legal DescriptioO / �ri te�//�� /��s� , ;� C9-40/4411COOIRCPo �. Setbacks Front Side Side Rear This Card Must Be Posted So It is Plainly Visible From The Street Until Final Inspection. INSPECTION RECORD Footing i - Foundation I/ry Siga Underground Plumbing b.a, 40 ! LInsulation 0- ? -, I gill ' ' Rough Plumbing (J Sp fj� Drywall , "CTIJa Chimney & Vent /0-/7 n/,B,tn Electric Final (by State Ins . - tor) -o -0. c. c Cas Piping D- -a , ACM Final 2. -4 D' e Electric Rough (By State Inspector) ; " � Septic Final Framing 41-44) (To include Roof in place and Windows and Doors installed). Notes: �J moi 41.0 ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING - WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND. THIS PERMIT IS NOT TRANSFERABLE Phone 384-5003 109 8th Street County Courthouse Glenwood Springs, Colorado. APP OVEDDO NOT DESTROY THIS CARD Dat: rice•^ a By LACED OUTSIDE - COVER WITH CLEAR PLASTIC J